@zwave-js/config 11.9.0 → 11.10.0

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (77) hide show
  1. package/config/devices/0x0109/yrd210.json +1 -1
  2. package/config/devices/0x0129/nf-yrc612-zw3.json +63 -0
  3. package/config/devices/0x0129/nf-yrc622-zw3.json +67 -0
  4. package/config/devices/0x0129/nf-yrd612-zw2.json +1 -1
  5. package/config/devices/0x0129/nf-yrd612-zw3.json +27 -34
  6. package/config/devices/0x0129/nf-yrd622-zw2.json +1 -1
  7. package/config/devices/0x0129/nf-yrd622-zw3.json +67 -0
  8. package/config/devices/0x0129/ntb610.json +1 -1
  9. package/config/devices/0x0129/ntb612-zw2.json +1 -1
  10. package/config/devices/0x0129/ntb620.json +1 -1
  11. package/config/devices/0x0129/ntb622-zw2.json +1 -1
  12. package/config/devices/0x0129/ntb632-zw2.json +1 -1
  13. package/config/devices/0x0129/ntb642-zw2.json +1 -1
  14. package/config/devices/0x0129/ntm610.json +1 -1
  15. package/config/devices/0x0129/ntm612-zw2.json +1 -1
  16. package/config/devices/0x0129/ntm617-zw2.json +1 -1
  17. package/config/devices/0x0129/ntm622-zw2.json +1 -1
  18. package/config/devices/0x0129/ntm625.json +1 -1
  19. package/config/devices/0x0129/ntm627-zw2.json +1 -1
  20. package/config/devices/0x0129/ntm632-zw2.json +1 -1
  21. package/config/devices/0x0129/ntm637-zw2.json +1 -1
  22. package/config/devices/0x0129/ntm642-zw2.json +1 -1
  23. package/config/devices/0x0129/ntm647-zw2.json +1 -1
  24. package/config/devices/0x0129/ntt610.json +1 -1
  25. package/config/devices/0x0129/ntt612-zw2.json +1 -1
  26. package/config/devices/0x0129/ntt620-zw2.json +1 -1
  27. package/config/devices/0x0129/ntt622-zw2.json +1 -1
  28. package/config/devices/0x0129/templates/yale_template.json +78 -6
  29. package/config/devices/0x0129/yrc216-zw3.json +11 -49
  30. package/config/devices/0x0129/yrc226-zw3.json +13 -21
  31. package/config/devices/0x0129/yrc256-zw3.json +13 -21
  32. package/config/devices/0x0129/yrc622-zw3.json +75 -0
  33. package/config/devices/0x0129/yrc642-zw3.json +75 -0
  34. package/config/devices/0x0129/yrc652-zw3.json +67 -0
  35. package/config/devices/0x0129/{yrd256.json → yrc_yrd_226_246_256_446-zw2.json} +5 -1
  36. package/config/devices/0x0129/yrd110.json +1 -1
  37. package/config/devices/0x0129/yrd120.json +1 -1
  38. package/config/devices/0x0129/yrd136.json +1 -1
  39. package/config/devices/0x0129/yrd156.json +1 -1
  40. package/config/devices/0x0129/yrd210.json +1 -1
  41. package/config/devices/0x0129/{yrd216.json → yrd216-zw2.json} +1 -1
  42. package/config/devices/0x0129/yrd216-zw3.json +14 -26
  43. package/config/devices/0x0129/yrd220.json +1 -1
  44. package/config/devices/0x0129/yrd226-zw3.json +13 -21
  45. package/config/devices/0x0129/yrd256-zw3.json +10 -52
  46. package/config/devices/0x0129/yrd410-zw2.json +1 -1
  47. package/config/devices/0x0129/yrd410-zw3.json +63 -0
  48. package/config/devices/0x0129/yrd416.json +1 -1
  49. package/config/devices/0x0129/yrd420-zw2.json +1 -1
  50. package/config/devices/0x0129/yrd420-zw3.json +63 -0
  51. package/config/devices/0x0129/yrd430-zw2.json +1 -1
  52. package/config/devices/0x0129/yrd430-zw3.json +63 -0
  53. package/config/devices/0x0129/yrd446.json +1 -1
  54. package/config/devices/0x0129/yrd450-zw2.json +1 -1
  55. package/config/devices/0x0129/yrd450-zw3.json +63 -0
  56. package/config/devices/0x0129/yrd620.json +1 -1
  57. package/config/devices/0x0129/yrd622-zw2.json +1 -1
  58. package/config/devices/0x0129/yrd622-zw3.json +75 -0
  59. package/config/devices/0x0129/yrd642-zw2.json +1 -1
  60. package/config/devices/0x0129/yrd642-zw3.json +75 -0
  61. package/config/devices/0x0129/yrd652-zw2.json +1 -1
  62. package/config/devices/0x0129/yrd652-zw3.json +29 -36
  63. package/config/devices/0x0129/yrl210.json +1 -1
  64. package/config/devices/0x0129/yrl216.json +1 -1
  65. package/config/devices/0x0129/yrl220.json +1 -1
  66. package/config/devices/0x0129/yrl226.json +1 -1
  67. package/config/devices/0x0129/yrl256.json +1 -1
  68. package/config/devices/0x0129/yrm276.json +1 -1
  69. package/config/devices/0x0129/yrm476.json +1 -1
  70. package/config/devices/0x014f/pd300emz5-1.json +3 -3
  71. package/config/devices/0x015f/mh-s411-7102.json +233 -0
  72. package/config/devices/0x015f/mh-s412-7102.json +234 -0
  73. package/config/devices/0x0312/mp21zp_mp31zp.json +25 -0
  74. package/config/devices/0x0312/templates/minoston_template.json +34 -0
  75. package/package.json +3 -3
  76. /package/config/devices/0x015f/{mh-s411-1502.json → mh-s411-5102.json} +0 -0
  77. /package/config/devices/0x015f/{mh-s412-1502.json → mh-s412-5102.json} +0 -0
@@ -2,7 +2,7 @@
2
2
  "manufacturer": "Yale",
3
3
  "manufacturerId": "0x0129",
4
4
  "label": "YRC216-ZW3",
5
- "description": "Interconnected Z-Wave Enabled Keypad Deadbolt",
5
+ "description": "Interconnected Push Button Deadbolt",
6
6
  "devices": [
7
7
  {
8
8
  "productType": "0x8004",
@@ -14,39 +14,10 @@
14
14
  "min": "0.0",
15
15
  "max": "255.255"
16
16
  },
17
- "associations": {
18
- "1": {
19
- "label": "Lifeline",
20
- "maxNodes": 3,
21
- "isLifeline": true
22
- }
23
- },
24
17
  "paramInformation": [
25
18
  {
26
19
  "#": "1",
27
- "label": "Volume",
28
- "valueSize": 1,
29
- "defaultValue": 2,
30
- "unsigned": true,
31
- "allowManualEntry": false,
32
- "options": [
33
- {
34
- "label": "Disable",
35
- "value": 0
36
- },
37
- {
38
- "label": "High",
39
- "value": 1
40
- },
41
- {
42
- "label": "Medium",
43
- "value": 2
44
- },
45
- {
46
- "label": "Low",
47
- "value": 3
48
- }
49
- ]
20
+ "$import": "templates/yale_template.json#volume_two_options"
50
21
  },
51
22
  {
52
23
  "#": "2",
@@ -54,27 +25,24 @@
54
25
  },
55
26
  {
56
27
  "#": "3",
57
- "$import": "templates/yale_template.json#auto_relock_time_127"
28
+ "$import": "templates/yale_template.json#auto_relock_time_180"
58
29
  },
59
30
  {
60
31
  "#": "4",
61
32
  "$import": "templates/yale_template.json#wrong_code_limit_3_to_10"
62
33
  },
63
- {
64
- "#": "5",
65
- "$import": "templates/yale_template.json#language"
66
- },
67
34
  {
68
35
  "#": "7",
69
- "$import": "templates/yale_template.json#wrong_code_lockout_0_to_127"
36
+ "$import": "templates/yale_template.json#wrong_code_lockout_10_to_132"
70
37
  },
71
38
  {
72
39
  "#": "8",
73
- "$import": "templates/yale_template.json#operating_mode"
40
+ "$import": "templates/yale_template.json#operating_mode_normal_vacation_privacy"
74
41
  },
75
42
  {
76
43
  "#": "11",
77
- "$import": "templates/yale_template.json#one_touch"
44
+ "$import": "templates/yale_template.json#one_touch",
45
+ "defaultValue": 255
78
46
  },
79
47
  {
80
48
  "#": "12",
@@ -85,18 +53,12 @@
85
53
  "$import": "templates/yale_template.json#lock_status_led"
86
54
  },
87
55
  {
88
- "#": "15",
89
- "$import": "templates/yale_template.json#reset_factory_255"
90
- },
91
- {
92
- "#": "6",
93
- "$import": "templates/yale_template.json#wrong_code_lockout_0_to_127"
56
+ "#": "28",
57
+ "$import": "templates/yale_template.json#expiring_pin_lifetime"
94
58
  }
95
59
  ],
96
60
  "metadata": {
97
- "inclusion": "Install Yale Smart Module into slot above battery compartment\nIMPORTANT: Batteries must be removed before inserting Yale Smart Module:\n• Remove battery cover\n• Remove batteries\n• Insert Yale Smart Module\n• Reinstall batteries\n• Reinstall battery cover\n2. Open Z-Wave system's smart home or alarm app on your smartphone or tablet\n3. If you have Smart Start* enabled with your Z-Wave System follow in-app prompts to add a new device\nIf you don't have smart start or are not sure, follow steps 4 - 6\n4. On your lock keypad, enter your master entry code followed by the gear icon\n5. Press the 7 key followed by the gear icon\n6. Press the 1 key followed by the gear icon",
98
- "exclusion": "Open Z-Wave system's smart home or alarm app and follow instructions for removing a device\n2. On your lock keypad, enter your master entry code followed by the icon\n3. Press the 7 key followed by the gear icon\n4. Press the 3 key followed by the gear icon",
99
- "reset": "Remove the battery cover and batteries.\nRemove the interior escutcheon to access the reset button.\nThe reset button is located above the PCB cable connector.\nWhile pressing the reset button for a minimum of 3 seconds, reinstall batteries. Release reset button.\nReplace battery cover. \nPlease use this procedure only when the network primary controller is missing or otherwise inoperable",
100
- "manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/4097/YRC216%20Manual%20(1).pdf"
61
+ "$import": "templates/yale_template.json#assure_zw3_metadata",
62
+ "reset": "Remove the battery cover and batteries.\nRemove the interior escutcheon to access the reset button.\nThe reset button is located above the PCB cable connector.\nWhile pressing the reset button for a minimum of 3 seconds, reinstall batteries. Release reset button.\nReplace battery cover. \nPlease use this procedure only when the network primary controller is missing or otherwise inoperable"
101
63
  }
102
64
  }
@@ -2,7 +2,7 @@
2
2
  "manufacturer": "Yale",
3
3
  "manufacturerId": "0x0129",
4
4
  "label": "YRC226-ZW3",
5
- "description": "Assure Interconnected Z-Wave Enabled Touch Screen Deadbolt",
5
+ "description": "Assure Interconnected Keyed Touch Screen Deadbolt",
6
6
  "devices": [
7
7
  {
8
8
  "productType": "0x8002",
@@ -14,13 +14,6 @@
14
14
  "min": "0.0",
15
15
  "max": "255.255"
16
16
  },
17
- "associations": {
18
- "1": {
19
- "label": "Lifeline",
20
- "maxNodes": 3,
21
- "isLifeline": true
22
- }
23
- },
24
17
  "paramInformation": [
25
18
  {
26
19
  "#": "1",
@@ -32,27 +25,28 @@
32
25
  },
33
26
  {
34
27
  "#": "3",
35
- "$import": "templates/yale_template.json#auto_relock_time_127"
28
+ "$import": "templates/yale_template.json#auto_relock_time_180"
36
29
  },
37
30
  {
38
31
  "#": "4",
39
- "$import": "templates/yale_template.json#wrong_code_limit_5"
32
+ "$import": "templates/yale_template.json#wrong_code_limit_3_to_10"
40
33
  },
41
34
  {
42
35
  "#": "5",
43
36
  "$import": "templates/yale_template.json#language"
44
37
  },
45
38
  {
46
- "#": "6",
47
- "$import": "templates/yale_template.json#wrong_code_lockout_0_to_127"
39
+ "#": "7",
40
+ "$import": "templates/yale_template.json#wrong_code_lockout_10_to_132"
48
41
  },
49
42
  {
50
- "#": "7",
51
- "$import": "templates/yale_template.json#operating_mode"
43
+ "#": "8",
44
+ "$import": "templates/yale_template.json#operating_mode_normal_vacation_privacy"
52
45
  },
53
46
  {
54
47
  "#": "11",
55
- "$import": "templates/yale_template.json#one_touch"
48
+ "$import": "templates/yale_template.json#one_touch",
49
+ "defaultValue": 255
56
50
  },
57
51
  {
58
52
  "#": "12",
@@ -63,14 +57,12 @@
63
57
  "$import": "templates/yale_template.json#lock_status_led"
64
58
  },
65
59
  {
66
- "#": "8",
67
- "$import": "templates/yale_template.json#reset_factory"
60
+ "#": "28",
61
+ "$import": "templates/yale_template.json#expiring_pin_lifetime"
68
62
  }
69
63
  ],
70
64
  "metadata": {
71
- "inclusion": "Install Yale Smart Module into slot above battery compartment\nIMPORTANT: Batteries must be removed before inserting Yale Smart Module:\n• Remove battery cover\n• Remove batteries\n• Insert Yale Smart Module\n• Reinstall batteries\n• Reinstall battery cover\n2. Open Z-Wave system's smart home or alarm app on your smartphone or tablet\n3. If you have Smart Start* enabled with your Z-Wave System follow in-app prompts to add a new device\nIf you don't have smart start or are not sure, follow steps 4 - 6\n4. On your lock keypad, enter your master entry code followed by the gear icon\n5. Press the 7 key followed by the gear icon\n6. Press the 1 key followed by the gear icon",
72
- "exclusion": "Open Z-Wave system's smart home or alarm app and follow instructions for removing a device\n2. On your lock keypad, enter your master entry code followed by the icon\n3. Press the 7 key followed by the gear icon\n4. Press the 3 key followed by the gear icon",
73
- "reset": "Remove the battery cover and batteries.\nRemove the interior escutcheon to access the reset button.\nThe reset button is located above the PCB cable connector.\nWhile pressing the reset button for a minimum of 3 seconds, reinstall batteries. Release reset button.\nReplace battery cover. \nPlease use this procedure only when the network primary controller is missing or otherwise inoperable",
74
- "manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/4096/YRC226%20Manual.pdf"
65
+ "$import": "templates/yale_template.json#assure_zw3_metadata",
66
+ "reset": "Remove the battery cover and batteries.\nRemove the interior escutcheon to access the reset button.\nThe reset button is located above the PCB cable connector.\nWhile pressing the reset button for a minimum of 3 seconds, reinstall batteries. Release reset button.\nReplace battery cover. \nPlease use this procedure only when the network primary controller is missing or otherwise inoperable"
75
67
  }
76
68
  }
@@ -2,7 +2,7 @@
2
2
  "manufacturer": "Yale",
3
3
  "manufacturerId": "0x0129",
4
4
  "label": "YRC256-ZW3",
5
- "description": "Assure Interconnected Z-Wave Enabled SL Touch Screen Deadbolt",
5
+ "description": "Assure Interconnected Keyless Touch Screen Deadbolt",
6
6
  "devices": [
7
7
  {
8
8
  "productType": "0x8002",
@@ -14,13 +14,6 @@
14
14
  "min": "0.0",
15
15
  "max": "255.255"
16
16
  },
17
- "associations": {
18
- "1": {
19
- "label": "Lifeline",
20
- "maxNodes": 3,
21
- "isLifeline": true
22
- }
23
- },
24
17
  "paramInformation": [
25
18
  {
26
19
  "#": "1",
@@ -32,27 +25,28 @@
32
25
  },
33
26
  {
34
27
  "#": "3",
35
- "$import": "templates/yale_template.json#auto_relock_time_127"
28
+ "$import": "templates/yale_template.json#auto_relock_time_180"
36
29
  },
37
30
  {
38
31
  "#": "4",
39
- "$import": "templates/yale_template.json#wrong_code_limit_5"
32
+ "$import": "templates/yale_template.json#wrong_code_limit_3_to_10"
40
33
  },
41
34
  {
42
35
  "#": "5",
43
36
  "$import": "templates/yale_template.json#language"
44
37
  },
45
38
  {
46
- "#": "6",
47
- "$import": "templates/yale_template.json#wrong_code_lockout_0_to_127"
39
+ "#": "7",
40
+ "$import": "templates/yale_template.json#wrong_code_lockout_10_to_132"
48
41
  },
49
42
  {
50
- "#": "7",
51
- "$import": "templates/yale_template.json#operating_mode"
43
+ "#": "8",
44
+ "$import": "templates/yale_template.json#operating_mode_normal_vacation_privacy"
52
45
  },
53
46
  {
54
47
  "#": "11",
55
- "$import": "templates/yale_template.json#one_touch"
48
+ "$import": "templates/yale_template.json#one_touch",
49
+ "defaultValue": 255
56
50
  },
57
51
  {
58
52
  "#": "12",
@@ -63,14 +57,12 @@
63
57
  "$import": "templates/yale_template.json#lock_status_led"
64
58
  },
65
59
  {
66
- "#": "8",
67
- "$import": "templates/yale_template.json#reset_factory"
60
+ "#": "28",
61
+ "$import": "templates/yale_template.json#expiring_pin_lifetime"
68
62
  }
69
63
  ],
70
64
  "metadata": {
71
- "inclusion": "Install Yale Smart Module into slot above battery compartment\nIMPORTANT: Batteries must be removed before inserting Yale Smart Module:\n• Remove battery cover\n• Remove batteries\n• Insert Yale Smart Module\n• Reinstall batteries\n• Reinstall battery cover\n2. Open Z-Wave system's smart home or alarm app on your smartphone or tablet\n3. If you have Smart Start* enabled with your Z-Wave System follow in-app prompts to add a new device\nIf you don't have smart start or are not sure, follow steps 4 - 6\n4. On your lock keypad, enter your master entry code followed by the gear icon\n5. Press the 7 key followed by the gear icon\n6. Press the 1 key followed by the gear icon",
72
- "exclusion": "Open Z-Wave system's smart home or alarm app and follow instructions for removing a device\n2. On your lock keypad, enter your master entry code followed by the icon\n3. Press the 7 key followed by the gear icon\n4. Press the 3 key followed by the gear icon",
73
- "reset": "Remove the battery cover and batteries.\nRemove the interior escutcheon to access the reset button.\nThe reset button is located above the PCB cable connector.\nWhile pressing the reset button for a minimum of 3 seconds, reinstall batteries. Release reset button.\nReplace battery cover. \nPlease use this procedure only when the network primary controller is missing or otherwise inoperable",
74
- "manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/4095/YRC256%20Manual-compressed%20(1)-compressed.pdf"
65
+ "$import": "templates/yale_template.json#assure_zw3_metadata",
66
+ "reset": "Remove the battery cover and batteries.\nRemove the interior escutcheon to access the reset button.\nThe reset button is located above the PCB cable connector.\nWhile pressing the reset button for a minimum of 3 seconds, reinstall batteries. Release reset button.\nReplace battery cover. \nPlease use this procedure only when the network primary controller is missing or otherwise inoperable"
75
67
  }
76
68
  }
@@ -0,0 +1,75 @@
1
+ {
2
+ "manufacturer": "Yale",
3
+ "manufacturerId": "0x0129",
4
+ "label": "YRC622-ZW3",
5
+ "description": "Assure 2nd Generation Fire Rated Keyed Interconnected Touch Screen Deadbolt",
6
+ "devices": [
7
+ {
8
+ "productType": "0x8103",
9
+ "productId": "0x52c2"
10
+ }
11
+ ],
12
+ "firmwareVersion": {
13
+ "min": "0.0",
14
+ "max": "255.255"
15
+ },
16
+ "paramInformation": [
17
+ {
18
+ "#": "1",
19
+ "$import": "templates/yale_template.json#volume"
20
+ },
21
+ {
22
+ "#": "2",
23
+ "$import": "templates/yale_template.json#auto_relock"
24
+ },
25
+ {
26
+ "#": "3",
27
+ "$import": "templates/yale_template.json#auto_relock_time_180"
28
+ },
29
+ {
30
+ "#": "4",
31
+ "$import": "templates/yale_template.json#wrong_code_limit_3_to_10"
32
+ },
33
+ {
34
+ "#": "5",
35
+ "$import": "templates/yale_template.json#language"
36
+ },
37
+ {
38
+ "#": "7",
39
+ "$import": "templates/yale_template.json#wrong_code_lockout_10_to_132"
40
+ },
41
+ {
42
+ "#": "8",
43
+ "$import": "templates/yale_template.json#operating_mode_normal_vacation_privacy_passage"
44
+ },
45
+ {
46
+ "#": "11",
47
+ "$import": "templates/yale_template.json#one_touch",
48
+ "defaultValue": 255
49
+ },
50
+ {
51
+ "#": "12",
52
+ "$import": "templates/yale_template.json#privacy_button"
53
+ },
54
+ {
55
+ "#": "13",
56
+ "$import": "templates/yale_template.json#lock_status_led"
57
+ },
58
+ {
59
+ "#": "16",
60
+ "$import": "templates/yale_template.json#enable_escape_mode"
61
+ },
62
+ {
63
+ "#": "21",
64
+ "$import": "templates/yale_template.json#eco_mode"
65
+ },
66
+ {
67
+ "#": "28",
68
+ "$import": "templates/yale_template.json#expiring_pin_lifetime"
69
+ }
70
+ ],
71
+ "metadata": {
72
+ "$import": "templates/yale_template.json#assure_zw3_metadata",
73
+ "reset": "Remove the battery cover and batteries.\nRemove the interior escutcheon to access the reset button.\nThe reset button is located above the PCB cable connector.\nWhile pressing the reset button for a minimum of 3 seconds, reinstall batteries. Release reset button.\nReplace battery cover. \nPlease use this procedure only when the network primary controller is missing or otherwise inoperable"
74
+ }
75
+ }
@@ -0,0 +1,75 @@
1
+ {
2
+ "manufacturer": "Yale",
3
+ "manufacturerId": "0x0129",
4
+ "label": "YRC642-ZW3",
5
+ "description": "Assure 2nd Generation Fire Rated Keyless Interconnected Touch Screen Deadbolt",
6
+ "devices": [
7
+ {
8
+ "productType": "0x8103",
9
+ "productId": "0x52c4"
10
+ }
11
+ ],
12
+ "firmwareVersion": {
13
+ "min": "0.0",
14
+ "max": "255.255"
15
+ },
16
+ "paramInformation": [
17
+ {
18
+ "#": "1",
19
+ "$import": "templates/yale_template.json#volume"
20
+ },
21
+ {
22
+ "#": "2",
23
+ "$import": "templates/yale_template.json#auto_relock"
24
+ },
25
+ {
26
+ "#": "3",
27
+ "$import": "templates/yale_template.json#auto_relock_time_180"
28
+ },
29
+ {
30
+ "#": "4",
31
+ "$import": "templates/yale_template.json#wrong_code_limit_3_to_10"
32
+ },
33
+ {
34
+ "#": "5",
35
+ "$import": "templates/yale_template.json#language"
36
+ },
37
+ {
38
+ "#": "7",
39
+ "$import": "templates/yale_template.json#wrong_code_lockout_10_to_132"
40
+ },
41
+ {
42
+ "#": "8",
43
+ "$import": "templates/yale_template.json#operating_mode_normal_vacation_privacy_passage"
44
+ },
45
+ {
46
+ "#": "11",
47
+ "$import": "templates/yale_template.json#one_touch",
48
+ "defaultValue": 255
49
+ },
50
+ {
51
+ "#": "12",
52
+ "$import": "templates/yale_template.json#privacy_button"
53
+ },
54
+ {
55
+ "#": "13",
56
+ "$import": "templates/yale_template.json#lock_status_led"
57
+ },
58
+ {
59
+ "#": "16",
60
+ "$import": "templates/yale_template.json#enable_escape_mode"
61
+ },
62
+ {
63
+ "#": "21",
64
+ "$import": "templates/yale_template.json#eco_mode"
65
+ },
66
+ {
67
+ "#": "28",
68
+ "$import": "templates/yale_template.json#expiring_pin_lifetime"
69
+ }
70
+ ],
71
+ "metadata": {
72
+ "$import": "templates/yale_template.json#assure_zw3_metadata",
73
+ "reset": "Remove the battery cover and batteries.\nRemove the interior escutcheon to access the reset button.\nThe reset button is located above the PCB cable connector.\nWhile pressing the reset button for a minimum of 3 seconds, reinstall batteries. Release reset button.\nReplace battery cover. \nPlease use this procedure only when the network primary controller is missing or otherwise inoperable"
74
+ }
75
+ }
@@ -0,0 +1,67 @@
1
+ {
2
+ "manufacturer": "Yale",
3
+ "manufacturerId": "0x0129",
4
+ "label": "YRC652-ZW3",
5
+ "description": "Assure 2nd Generation Interconnected Keyless Touch Screen Deadbolt",
6
+ "devices": [
7
+ {
8
+ "productType": "0x8109",
9
+ "productId": "0x4dc5"
10
+ }
11
+ ],
12
+ "firmwareVersion": {
13
+ "min": "0.0",
14
+ "max": "255.255"
15
+ },
16
+ "paramInformation": [
17
+ {
18
+ "#": "1",
19
+ "$import": "templates/yale_template.json#volume"
20
+ },
21
+ {
22
+ "#": "2",
23
+ "$import": "templates/yale_template.json#auto_relock"
24
+ },
25
+ {
26
+ "#": "3",
27
+ "$import": "templates/yale_template.json#auto_relock_time_180"
28
+ },
29
+ {
30
+ "#": "4",
31
+ "$import": "templates/yale_template.json#wrong_code_limit_3_to_10"
32
+ },
33
+ {
34
+ "#": "5",
35
+ "$import": "templates/yale_template.json#language"
36
+ },
37
+ {
38
+ "#": "7",
39
+ "$import": "templates/yale_template.json#wrong_code_lockout_10_to_132"
40
+ },
41
+ {
42
+ "#": "8",
43
+ "$import": "templates/yale_template.json#operating_mode_normal_vacation_privacy"
44
+ },
45
+ {
46
+ "#": "11",
47
+ "$import": "templates/yale_template.json#one_touch",
48
+ "defaultValue": 255
49
+ },
50
+ {
51
+ "#": "12",
52
+ "$import": "templates/yale_template.json#privacy_button"
53
+ },
54
+ {
55
+ "#": "13",
56
+ "$import": "templates/yale_template.json#lock_status_led"
57
+ },
58
+ {
59
+ "#": "28",
60
+ "$import": "templates/yale_template.json#expiring_pin_lifetime"
61
+ }
62
+ ],
63
+ "metadata": {
64
+ "$import": "templates/yale_template.json#assure_zw3_metadata",
65
+ "reset": "When lock is reset to factory defaults all Entry Codes\n(including the Master Entry Code*) are deleted and all\nprogramming features are reset to original default\nsettings (see below).\n1. Remove battery cover and batteries.\n2. Remove inside lock to access reset button.\n3. Reset button (see image at right) is located beside\ncable adapter.\n4. While pressing reset button reinstall batteries. Hold\nreset button a minimum of 3 seconds then release.\n5. Replace battery cover.\nAfter reset, Master Entry Code creation is the only\noption available and must be performed prior to\nany other programming of the lock"
66
+ }
67
+ }
@@ -9,6 +9,10 @@
9
9
  "productId": "0x0600",
10
10
  "zwaveAllianceId": [1878, 1972, 1973, 3211, 3299, 3401, 3418]
11
11
  },
12
+ {
13
+ "productType": "0x8002",
14
+ "productId": "0x1600"
15
+ },
12
16
  {
13
17
  "productType": "0x8002",
14
18
  "productId": "0x4600"
@@ -50,7 +54,7 @@
50
54
  },
51
55
  {
52
56
  "#": "8",
53
- "$import": "templates/yale_template.json#operating_mode"
57
+ "$import": "templates/yale_template.json#operating_mode_normal_vacation_privacy"
54
58
  },
55
59
  {
56
60
  "#": "11",
@@ -44,7 +44,7 @@
44
44
  },
45
45
  {
46
46
  "#": "8",
47
- "$import": "templates/yale_template.json#operating_mode"
47
+ "$import": "templates/yale_template.json#operating_mode_normal_vacation_privacy"
48
48
  }
49
49
  ],
50
50
  "compat": {
@@ -44,7 +44,7 @@
44
44
  },
45
45
  {
46
46
  "#": "8",
47
- "$import": "templates/yale_template.json#operating_mode"
47
+ "$import": "templates/yale_template.json#operating_mode_normal_vacation_privacy"
48
48
  }
49
49
  ],
50
50
  "compat": {
@@ -37,7 +37,7 @@
37
37
  },
38
38
  {
39
39
  "#": "8",
40
- "$import": "templates/yale_template.json#operating_mode"
40
+ "$import": "templates/yale_template.json#operating_mode_normal_vacation_privacy"
41
41
  },
42
42
  {
43
43
  "#": "11",
@@ -37,7 +37,7 @@
37
37
  },
38
38
  {
39
39
  "#": "8",
40
- "$import": "templates/yale_template.json#operating_mode"
40
+ "$import": "templates/yale_template.json#operating_mode_normal_vacation_privacy"
41
41
  },
42
42
  {
43
43
  "#": "11",
@@ -60,7 +60,7 @@
60
60
  },
61
61
  {
62
62
  "#": "8",
63
- "$import": "templates/yale_template.json#operating_mode"
63
+ "$import": "templates/yale_template.json#operating_mode_normal_vacation_privacy"
64
64
  }
65
65
  ],
66
66
  "compat": {
@@ -41,7 +41,7 @@
41
41
  },
42
42
  {
43
43
  "#": "8",
44
- "$import": "templates/yale_template.json#operating_mode"
44
+ "$import": "templates/yale_template.json#operating_mode_normal_vacation_privacy"
45
45
  },
46
46
  {
47
47
  "#": "11",
@@ -2,7 +2,7 @@
2
2
  "manufacturer": "Yale",
3
3
  "manufacturerId": "0x0129",
4
4
  "label": "YRD216-ZW3",
5
- "description": "Assure Z-Wave Enabled Keypad Deadbolt",
5
+ "description": "Assure Keyed Push Button Deadbolt",
6
6
  "devices": [
7
7
  {
8
8
  "productType": "0x8004",
@@ -14,17 +14,10 @@
14
14
  "min": "0.0",
15
15
  "max": "255.255"
16
16
  },
17
- "associations": {
18
- "1": {
19
- "label": "Lifeline",
20
- "maxNodes": 3,
21
- "isLifeline": true
22
- }
23
- },
24
17
  "paramInformation": [
25
18
  {
26
19
  "#": "1",
27
- "$import": "templates/yale_template.json#volume"
20
+ "$import": "templates/yale_template.json#volume_two_options"
28
21
  },
29
22
  {
30
23
  "#": "2",
@@ -32,27 +25,24 @@
32
25
  },
33
26
  {
34
27
  "#": "3",
35
- "$import": "templates/yale_template.json#auto_relock_time_127"
28
+ "$import": "templates/yale_template.json#auto_relock_time_180"
36
29
  },
37
30
  {
38
31
  "#": "4",
39
- "$import": "templates/yale_template.json#wrong_code_limit_5"
40
- },
41
- {
42
- "#": "5",
43
- "$import": "templates/yale_template.json#language"
32
+ "$import": "templates/yale_template.json#wrong_code_limit_3_to_10"
44
33
  },
45
34
  {
46
- "#": "6",
47
- "$import": "templates/yale_template.json#wrong_code_lockout_0_to_127"
35
+ "#": "7",
36
+ "$import": "templates/yale_template.json#wrong_code_lockout_10_to_132"
48
37
  },
49
38
  {
50
- "#": "7",
51
- "$import": "templates/yale_template.json#operating_mode"
39
+ "#": "8",
40
+ "$import": "templates/yale_template.json#operating_mode_normal_vacation_privacy"
52
41
  },
53
42
  {
54
43
  "#": "11",
55
- "$import": "templates/yale_template.json#one_touch"
44
+ "$import": "templates/yale_template.json#one_touch",
45
+ "defaultValue": 255
56
46
  },
57
47
  {
58
48
  "#": "12",
@@ -63,14 +53,12 @@
63
53
  "$import": "templates/yale_template.json#lock_status_led"
64
54
  },
65
55
  {
66
- "#": "8",
67
- "$import": "templates/yale_template.json#reset_factory"
56
+ "#": "28",
57
+ "$import": "templates/yale_template.json#expiring_pin_lifetime"
68
58
  }
69
59
  ],
70
60
  "metadata": {
71
- "inclusion": "Install Yale Smart Module into slot above battery compartment\nIMPORTANT: Batteries must be removed before inserting Yale Smart Module:\n• Remove battery cover\n• Remove batteries\n• Insert Yale Smart Module\n• Reinstall batteries\n• Reinstall battery cover\n2. Open Z-Wave system's smart home or alarm app on your smartphone or tablet\n3. If you have Smart Start* enabled with your Z-Wave System follow in-app prompts to add a new device\nIf you don't have smart start or are not sure, follow steps 4 - 6\n4. On your lock keypad, enter your master entry code followed by the gear icon\n5. Press the 7 key followed by the gear icon\n6. Press the 1 key followed by the gear icon",
72
- "exclusion": "Open Z-Wave system's smart home or alarm app and follow instructions for removing a device\n2. On your lock keypad, enter your master entry code followed by the icon\n3. Press the 7 key followed by the gear icon\n4. Press the 3 key followed by the gear icon",
73
- "reset": "Remove the battery cover and batteries.\nRemove the interior escutcheon to access the reset button.\nThe reset button is located above the PCB cable connector.\nWhile pressing the reset button for a minimum of 3 seconds, reinstall batteries. Release reset button.\nReplace battery cover. \nPlease use this procedure only when the network primary controller is missing or otherwise inoperable",
74
- "manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/4094/YRD216%20Manual.pdf"
61
+ "$import": "templates/yale_template.json#assure_zw3_metadata",
62
+ "reset": "Remove the battery cover and batteries.\nRemove the interior escutcheon to access the reset button.\nThe reset button is located above the PCB cable connector.\nWhile pressing the reset button for a minimum of 3 seconds, reinstall batteries. Release reset button.\nReplace battery cover. \nPlease use this procedure only when the network primary controller is missing or otherwise inoperable"
75
63
  }
76
64
  }
@@ -64,7 +64,7 @@
64
64
  },
65
65
  {
66
66
  "#": "8",
67
- "$import": "templates/yale_template.json#operating_mode"
67
+ "$import": "templates/yale_template.json#operating_mode_normal_vacation_privacy"
68
68
  },
69
69
  {
70
70
  "#": "11",