@zwave-js/config 11.0.0-beta.0 → 11.0.0-beta.1
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/build/ConfigManager.d.ts +8 -8
- package/build/ConfigManager.d.ts.map +1 -1
- package/build/ConfigManager.js.map +1 -1
- package/build/DeviceClasses.d.ts +1 -1
- package/build/DeviceClasses.d.ts.map +1 -1
- package/build/DeviceClasses.js.map +1 -1
- package/build/Indicators.d.ts +1 -1
- package/build/Indicators.d.ts.map +1 -1
- package/build/Indicators.js.map +1 -1
- package/build/Logger.d.ts +2 -2
- package/build/Logger.d.ts.map +1 -1
- package/build/Logger.js.map +1 -1
- package/build/Logic.d.ts +1 -1
- package/build/Logic.d.ts.map +1 -1
- package/build/Logic.js.map +1 -1
- package/build/Meters.d.ts +1 -1
- package/build/Meters.d.ts.map +1 -1
- package/build/Meters.js.map +1 -1
- package/build/Notifications.d.ts +1 -1
- package/build/Notifications.d.ts.map +1 -1
- package/build/Notifications.js.map +1 -1
- package/build/Scales.d.ts +1 -1
- package/build/Scales.d.ts.map +1 -1
- package/build/Scales.js.map +1 -1
- package/build/SensorTypes.d.ts +2 -2
- package/build/SensorTypes.d.ts.map +1 -1
- package/build/SensorTypes.js.map +1 -1
- package/build/devices/AssociationConfig.d.ts +2 -2
- package/build/devices/AssociationConfig.d.ts.map +1 -1
- package/build/devices/AssociationConfig.js.map +1 -1
- package/build/devices/CompatConfig.d.ts +2 -2
- package/build/devices/CompatConfig.d.ts.map +1 -1
- package/build/devices/CompatConfig.js.map +1 -1
- package/build/devices/DeviceConfig.d.ts +5 -5
- package/build/devices/DeviceConfig.d.ts.map +1 -1
- package/build/devices/DeviceConfig.js.map +1 -1
- package/build/devices/DeviceMetadata.d.ts +2 -2
- package/build/devices/DeviceMetadata.d.ts.map +1 -1
- package/build/devices/EndpointConfig.d.ts +2 -2
- package/build/devices/EndpointConfig.d.ts.map +1 -1
- package/build/devices/ParamInformation.d.ts +2 -2
- package/build/devices/ParamInformation.d.ts.map +1 -1
- package/build/index.d.ts +7 -7
- package/build/index.d.ts.map +1 -1
- package/build/index.js +7 -7
- package/build/index.js.map +1 -1
- package/build/utils.d.ts +1 -1
- package/build/utils.d.ts.map +1 -1
- package/config/devices/0x0064/zw_esj_300.json +77 -12
- package/config/devices/0x0090/914c.json +4 -0
- package/config/devices/0x018c/pm-140-zw.json +32 -0
- package/config/devices/0x018c/pm-240-zw.json +6 -0
- package/config/devices/0x018c/pm-340-zw.json +32 -0
- package/config/devices/0x018c/ssd-105.json +72 -0
- package/config/devices/0x018c/ssd-205.json +76 -0
- package/config/devices/0x018c/ssd-305.json +80 -0
- package/config/devices/0x021c/dl9101v.json +1 -1
- package/config/devices/0x021c/dx1wl-z.json +1 -1
- package/config/devices/0x021c/ilock15.json +3 -4
- package/config/devices/0x021c/j1504.json +1 -1
- package/config/devices/0x021c/j1505.json +1 -1
- package/config/devices/0x021c/j1506.json +1 -1
- package/config/devices/0x021c/j1825.json +27 -0
- package/config/devices/0x021c/smoke_detector.json +1 -1
- package/config/devices/0x0233/sse-302.json +21 -2
- package/config/devices/0x0233/sse-303.json +1 -1
- package/config/devices/0x0233/sse-304.json +80 -0
- package/config/devices/0x0357/{upowerswitch.json → upowerswitch_1.json} +21 -21
- package/config/devices/0x0357/upowerswitch_2.json +68 -0
- package/config/devices/0x0357/upowerswitch_3.json +68 -0
- package/package.json +7 -7
- package/config/devices/0x021c/ilock.json +0 -16
|
@@ -1,13 +1,12 @@
|
|
|
1
1
|
{
|
|
2
|
-
"manufacturer": "Shenzhen iSurpass Technology Co
|
|
2
|
+
"manufacturer": "Shenzhen iSurpass Technology Co., Ltd.",
|
|
3
3
|
"manufacturerId": "0x021c",
|
|
4
4
|
"label": "ILOCK15",
|
|
5
5
|
"description": "Smart Door Lock",
|
|
6
6
|
"devices": [
|
|
7
7
|
{
|
|
8
|
-
"productType": "
|
|
9
|
-
"productId": "
|
|
10
|
-
"zwaveAllianceId": 3048
|
|
8
|
+
"productType": "0x634b",
|
|
9
|
+
"productId": "0x504c"
|
|
11
10
|
}
|
|
12
11
|
],
|
|
13
12
|
"firmwareVersion": {
|
|
@@ -0,0 +1,27 @@
|
|
|
1
|
+
{
|
|
2
|
+
"manufacturer": "Shenzhen iSurpass Technology Co., Ltd",
|
|
3
|
+
"manufacturerId": "0x021c",
|
|
4
|
+
"label": "J1825",
|
|
5
|
+
"description": "Wall Reader",
|
|
6
|
+
"devices": [
|
|
7
|
+
{
|
|
8
|
+
"productType": "0x5010",
|
|
9
|
+
"productId": "0x1001"
|
|
10
|
+
}
|
|
11
|
+
],
|
|
12
|
+
"firmwareVersion": {
|
|
13
|
+
"min": "0.0",
|
|
14
|
+
"max": "255.255"
|
|
15
|
+
},
|
|
16
|
+
"associations": {
|
|
17
|
+
"1": {
|
|
18
|
+
"label": "Lifeline",
|
|
19
|
+
"maxNodes": 1,
|
|
20
|
+
"isLifeline": true
|
|
21
|
+
},
|
|
22
|
+
"2": {
|
|
23
|
+
"label": "Notification Report",
|
|
24
|
+
"maxNodes": 5
|
|
25
|
+
}
|
|
26
|
+
}
|
|
27
|
+
}
|
|
@@ -1,8 +1,8 @@
|
|
|
1
1
|
{
|
|
2
|
-
"manufacturer": "
|
|
2
|
+
"manufacturer": "LG U+",
|
|
3
3
|
"manufacturerId": "0x0233",
|
|
4
4
|
"label": "SSE-302",
|
|
5
|
-
"description": "
|
|
5
|
+
"description": "Smart Switch",
|
|
6
6
|
"devices": [
|
|
7
7
|
{
|
|
8
8
|
"productType": "0x004c",
|
|
@@ -14,6 +14,25 @@
|
|
|
14
14
|
"min": "0.0",
|
|
15
15
|
"max": "255.255"
|
|
16
16
|
},
|
|
17
|
+
"associations": {
|
|
18
|
+
"1": {
|
|
19
|
+
"label": "Lifeline",
|
|
20
|
+
"maxNodes": 5,
|
|
21
|
+
"isLifeline": true
|
|
22
|
+
},
|
|
23
|
+
"2": {
|
|
24
|
+
"label": "Switch 1",
|
|
25
|
+
"maxNodes": 5
|
|
26
|
+
},
|
|
27
|
+
"3": {
|
|
28
|
+
"label": "Switch 2",
|
|
29
|
+
"maxNodes": 5
|
|
30
|
+
},
|
|
31
|
+
"4": {
|
|
32
|
+
"label": "Switch 3",
|
|
33
|
+
"maxNodes": 5
|
|
34
|
+
}
|
|
35
|
+
},
|
|
17
36
|
"metadata": {
|
|
18
37
|
"inclusion": "1) Prepare the controller for enabling inclusion\n2) Keep touching the lamp low button, then after 5 seconds elapsed, 3 beep sounds can be heard. At that time, withdraw touching the button and then inclusion will be commenced",
|
|
19
38
|
"exclusion": "1) Make sure the switch is in inclusion mode.\n2) Keep touching the lamp low button, then after 5 seconds elapsed, 3 beep sounds can be heard. At that time, withdraw touching the button and then exclusion will be started",
|
|
@@ -0,0 +1,80 @@
|
|
|
1
|
+
{
|
|
2
|
+
"manufacturer": "LG U+",
|
|
3
|
+
"manufacturerId": "0x0233",
|
|
4
|
+
"label": "SSE-304",
|
|
5
|
+
"description": "IoT Switch",
|
|
6
|
+
"devices": [
|
|
7
|
+
{
|
|
8
|
+
"productType": "0x0059",
|
|
9
|
+
"productId": "0x0001",
|
|
10
|
+
"zwaveAllianceId": 3051
|
|
11
|
+
}
|
|
12
|
+
],
|
|
13
|
+
"firmwareVersion": {
|
|
14
|
+
"min": "0.0",
|
|
15
|
+
"max": "255.255"
|
|
16
|
+
},
|
|
17
|
+
"associations": {
|
|
18
|
+
"1": {
|
|
19
|
+
"label": "Lifeline",
|
|
20
|
+
"maxNodes": 5,
|
|
21
|
+
"isLifeline": true
|
|
22
|
+
},
|
|
23
|
+
"2": {
|
|
24
|
+
"label": "Switch 1",
|
|
25
|
+
"maxNodes": 5
|
|
26
|
+
},
|
|
27
|
+
"3": {
|
|
28
|
+
"label": "Switch 2",
|
|
29
|
+
"maxNodes": 5
|
|
30
|
+
},
|
|
31
|
+
"4": {
|
|
32
|
+
"label": "Switch 3",
|
|
33
|
+
"maxNodes": 5
|
|
34
|
+
}
|
|
35
|
+
},
|
|
36
|
+
"paramInformation": [
|
|
37
|
+
{
|
|
38
|
+
"#": "1",
|
|
39
|
+
"label": "Temperature & Humidity Reporting Interval",
|
|
40
|
+
"valueSize": 2,
|
|
41
|
+
"unit": "seconds",
|
|
42
|
+
"minValue": 0,
|
|
43
|
+
"maxValue": 3600,
|
|
44
|
+
"defaultValue": 600,
|
|
45
|
+
"unsigned": true,
|
|
46
|
+
"options": [
|
|
47
|
+
{
|
|
48
|
+
"label": "Disable",
|
|
49
|
+
"value": 0
|
|
50
|
+
}
|
|
51
|
+
]
|
|
52
|
+
},
|
|
53
|
+
{
|
|
54
|
+
"#": "2",
|
|
55
|
+
"label": "Temperature Change Report Threshold",
|
|
56
|
+
"valueSize": 1,
|
|
57
|
+
"unit": "0.1 °C",
|
|
58
|
+
"minValue": 10,
|
|
59
|
+
"maxValue": 30,
|
|
60
|
+
"defaultValue": 20,
|
|
61
|
+
"unsigned": true
|
|
62
|
+
},
|
|
63
|
+
{
|
|
64
|
+
"#": "3",
|
|
65
|
+
"label": "Humidity Change Report Threshold",
|
|
66
|
+
"valueSize": 1,
|
|
67
|
+
"unit": "%",
|
|
68
|
+
"minValue": 5,
|
|
69
|
+
"maxValue": 20,
|
|
70
|
+
"defaultValue": 10,
|
|
71
|
+
"unsigned": true
|
|
72
|
+
}
|
|
73
|
+
],
|
|
74
|
+
"metadata": {
|
|
75
|
+
"inclusion": "▶ Add / Remove by the button in the bottom (3rd Button)\n▶ Press the 3rd button for above 5 seconds,\n- Then, red color LED blinks every 0.5 second 6 times.\n- At this time released the button during the red color LED\n blinking.\n- Then, ZWAVE Add / Remove operation is started.\n- Over 30 seconds, Inclusion/ Exclusion mode is stopped",
|
|
76
|
+
"exclusion": "▶ Press the 3rd button for above 5 seconds,\n- Then, red color LED blinks every 0.5 second 6 times.\n- At this time released the button during the red color LED\n blinking.\n- Then, ZWAVE Add / Remove operation is started.\n- Over 30 seconds, Inclusion/ Exclusion mode is stopped",
|
|
77
|
+
"reset": "1) Hold the low touch button for 10 seconds.\n- Keep holding the button, then at 5 second, red LED of 3rd\n button is blinking 6 times and keep holding10 seconds\n later, red LED of 3rd is blinking 6 times again. In this time\n factory reset will be started if you release the button.\n2) After factory reset is done, all the lamps will be turned off\n and all variables will be initialized to default values.\n\nPlease use this procedure only when the network primary controller is missing or otherwise inoperable",
|
|
78
|
+
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/3051/Switch_Product_Manual_For_Certification_0801R.pdf"
|
|
79
|
+
}
|
|
80
|
+
}
|
|
@@ -1,47 +1,48 @@
|
|
|
1
1
|
{
|
|
2
|
-
"manufacturer": "
|
|
2
|
+
"manufacturer": "LG U+",
|
|
3
3
|
"manufacturerId": "0x0357",
|
|
4
4
|
"label": "UPowerSwitch",
|
|
5
|
-
"description": "",
|
|
5
|
+
"description": "1-Button Smart Switch",
|
|
6
6
|
"devices": [
|
|
7
7
|
{
|
|
8
8
|
"productType": "0x0057",
|
|
9
9
|
"productId": "0x0002",
|
|
10
10
|
"zwaveAllianceId": 3682
|
|
11
|
-
},
|
|
12
|
-
{
|
|
13
|
-
"productType": "0x0058",
|
|
14
|
-
"productId": "0x0002",
|
|
15
|
-
"zwaveAllianceId": 3683
|
|
16
|
-
},
|
|
17
|
-
{
|
|
18
|
-
"productType": "0x0059",
|
|
19
|
-
"productId": "0x0002",
|
|
20
|
-
"zwaveAllianceId": 3660
|
|
21
11
|
}
|
|
22
12
|
],
|
|
23
13
|
"firmwareVersion": {
|
|
24
14
|
"min": "0.0",
|
|
25
15
|
"max": "255.255"
|
|
26
16
|
},
|
|
17
|
+
"associations": {
|
|
18
|
+
"1": {
|
|
19
|
+
"label": "Lifeline",
|
|
20
|
+
"maxNodes": 5,
|
|
21
|
+
"isLifeline": true
|
|
22
|
+
}
|
|
23
|
+
},
|
|
27
24
|
"paramInformation": [
|
|
28
25
|
{
|
|
29
26
|
"#": "1",
|
|
30
|
-
"label": "
|
|
31
|
-
"description": "Time period of Multi Level Sensor Report.",
|
|
27
|
+
"label": "Temperature & Humidity Reporting Interval",
|
|
32
28
|
"valueSize": 2,
|
|
33
29
|
"unit": "seconds",
|
|
34
|
-
"minValue":
|
|
30
|
+
"minValue": 0,
|
|
35
31
|
"maxValue": 3600,
|
|
36
32
|
"defaultValue": 600,
|
|
37
|
-
"unsigned": true
|
|
33
|
+
"unsigned": true,
|
|
34
|
+
"options": [
|
|
35
|
+
{
|
|
36
|
+
"label": "Disable",
|
|
37
|
+
"value": 0
|
|
38
|
+
}
|
|
39
|
+
]
|
|
38
40
|
},
|
|
39
41
|
{
|
|
40
42
|
"#": "2",
|
|
41
|
-
"label": "
|
|
42
|
-
"description": "During the cycle, if the temperature change is greater than the set value, a report of the current temperature value will be immediately issued.",
|
|
43
|
+
"label": "Temperature Change Report Threshold",
|
|
43
44
|
"valueSize": 1,
|
|
44
|
-
"unit": ".1°C",
|
|
45
|
+
"unit": "0.1 °C",
|
|
45
46
|
"minValue": 10,
|
|
46
47
|
"maxValue": 30,
|
|
47
48
|
"defaultValue": 20,
|
|
@@ -49,8 +50,7 @@
|
|
|
49
50
|
},
|
|
50
51
|
{
|
|
51
52
|
"#": "3",
|
|
52
|
-
"label": "
|
|
53
|
-
"description": "During the cycle, if the humidity change is greater than the set value, a report of the current humidity value will be immediately issued.",
|
|
53
|
+
"label": "Humidity Change Report Threshold",
|
|
54
54
|
"valueSize": 1,
|
|
55
55
|
"unit": "%",
|
|
56
56
|
"minValue": 5,
|
|
@@ -0,0 +1,68 @@
|
|
|
1
|
+
{
|
|
2
|
+
"manufacturer": "LG U+",
|
|
3
|
+
"manufacturerId": "0x0357",
|
|
4
|
+
"label": "UPowerSwitch",
|
|
5
|
+
"description": "2-Button Smart Switch",
|
|
6
|
+
"devices": [
|
|
7
|
+
{
|
|
8
|
+
"productType": "0x0058",
|
|
9
|
+
"productId": "0x0002",
|
|
10
|
+
"zwaveAllianceId": 3683
|
|
11
|
+
}
|
|
12
|
+
],
|
|
13
|
+
"firmwareVersion": {
|
|
14
|
+
"min": "0.0",
|
|
15
|
+
"max": "255.255"
|
|
16
|
+
},
|
|
17
|
+
"associations": {
|
|
18
|
+
"1": {
|
|
19
|
+
"label": "Lifeline",
|
|
20
|
+
"maxNodes": 5,
|
|
21
|
+
"isLifeline": true
|
|
22
|
+
}
|
|
23
|
+
},
|
|
24
|
+
"paramInformation": [
|
|
25
|
+
{
|
|
26
|
+
"#": "1",
|
|
27
|
+
"label": "Temperature & Humidity Reporting Interval",
|
|
28
|
+
"valueSize": 2,
|
|
29
|
+
"unit": "seconds",
|
|
30
|
+
"minValue": 0,
|
|
31
|
+
"maxValue": 3600,
|
|
32
|
+
"defaultValue": 600,
|
|
33
|
+
"unsigned": true,
|
|
34
|
+
"options": [
|
|
35
|
+
{
|
|
36
|
+
"label": "Disable",
|
|
37
|
+
"value": 0
|
|
38
|
+
}
|
|
39
|
+
]
|
|
40
|
+
},
|
|
41
|
+
{
|
|
42
|
+
"#": "2",
|
|
43
|
+
"label": "Temperature Change Report Threshold",
|
|
44
|
+
"valueSize": 1,
|
|
45
|
+
"unit": "0.1 °C",
|
|
46
|
+
"minValue": 10,
|
|
47
|
+
"maxValue": 30,
|
|
48
|
+
"defaultValue": 20,
|
|
49
|
+
"unsigned": true
|
|
50
|
+
},
|
|
51
|
+
{
|
|
52
|
+
"#": "3",
|
|
53
|
+
"label": "Humidity Change Report Threshold",
|
|
54
|
+
"valueSize": 1,
|
|
55
|
+
"unit": "%",
|
|
56
|
+
"minValue": 5,
|
|
57
|
+
"maxValue": 20,
|
|
58
|
+
"defaultValue": 10,
|
|
59
|
+
"unsigned": true
|
|
60
|
+
}
|
|
61
|
+
],
|
|
62
|
+
"metadata": {
|
|
63
|
+
"inclusion": "Press the 3rd button for above 5 seconds. Then, red color LED blinks every 0.5 second 6 times. At this time released the button during the red color LED blinking. Then, ZWAVE Add / Remove operation is started",
|
|
64
|
+
"exclusion": "Press the 3rd button for above 5 seconds. Then, red color LED blinks every 0.5 second 6 times. At this time released the button during the red color LED blinking. Then, ZWAVE Add / Remove operation is started",
|
|
65
|
+
"reset": "Hold the low button for 10 seconds.\n-Keep holding the button, then at 5 second,red LED of 3rd button is blinking 6 times, and keep holding.\nThe red LED blinking 6 times after 10 seconds. When you release your hand, the LED will stop blinking and return to the factory settings.\n*NOTES: Use this procedure only when the network primary controller is missing or otherwise inoperable",
|
|
66
|
+
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/3660/SmartSwitch_Product_Manual_KO.pdf"
|
|
67
|
+
}
|
|
68
|
+
}
|
|
@@ -0,0 +1,68 @@
|
|
|
1
|
+
{
|
|
2
|
+
"manufacturer": "LG U+",
|
|
3
|
+
"manufacturerId": "0x0357",
|
|
4
|
+
"label": "UPowerSwitch",
|
|
5
|
+
"description": "3-Button Smart Switch",
|
|
6
|
+
"devices": [
|
|
7
|
+
{
|
|
8
|
+
"productType": "0x0059",
|
|
9
|
+
"productId": "0x0002",
|
|
10
|
+
"zwaveAllianceId": 3660
|
|
11
|
+
}
|
|
12
|
+
],
|
|
13
|
+
"firmwareVersion": {
|
|
14
|
+
"min": "0.0",
|
|
15
|
+
"max": "255.255"
|
|
16
|
+
},
|
|
17
|
+
"associations": {
|
|
18
|
+
"1": {
|
|
19
|
+
"label": "Lifeline",
|
|
20
|
+
"maxNodes": 5,
|
|
21
|
+
"isLifeline": true
|
|
22
|
+
}
|
|
23
|
+
},
|
|
24
|
+
"paramInformation": [
|
|
25
|
+
{
|
|
26
|
+
"#": "1",
|
|
27
|
+
"label": "Temperature & Humidity Reporting Interval",
|
|
28
|
+
"valueSize": 2,
|
|
29
|
+
"unit": "seconds",
|
|
30
|
+
"minValue": 0,
|
|
31
|
+
"maxValue": 3600,
|
|
32
|
+
"defaultValue": 600,
|
|
33
|
+
"unsigned": true,
|
|
34
|
+
"options": [
|
|
35
|
+
{
|
|
36
|
+
"label": "Disable",
|
|
37
|
+
"value": 0
|
|
38
|
+
}
|
|
39
|
+
]
|
|
40
|
+
},
|
|
41
|
+
{
|
|
42
|
+
"#": "2",
|
|
43
|
+
"label": "Temperature Change Report Threshold",
|
|
44
|
+
"valueSize": 1,
|
|
45
|
+
"unit": "0.1 °C",
|
|
46
|
+
"minValue": 10,
|
|
47
|
+
"maxValue": 30,
|
|
48
|
+
"defaultValue": 20,
|
|
49
|
+
"unsigned": true
|
|
50
|
+
},
|
|
51
|
+
{
|
|
52
|
+
"#": "3",
|
|
53
|
+
"label": "Humidity Change Report Threshold",
|
|
54
|
+
"valueSize": 1,
|
|
55
|
+
"unit": "%",
|
|
56
|
+
"minValue": 5,
|
|
57
|
+
"maxValue": 20,
|
|
58
|
+
"defaultValue": 10,
|
|
59
|
+
"unsigned": true
|
|
60
|
+
}
|
|
61
|
+
],
|
|
62
|
+
"metadata": {
|
|
63
|
+
"inclusion": "Press the 3rd button for above 5 seconds. Then, red color LED blinks every 0.5 second 6 times. At this time released the button during the red color LED blinking. Then, ZWAVE Add / Remove operation is started",
|
|
64
|
+
"exclusion": "Press the 3rd button for above 5 seconds. Then, red color LED blinks every 0.5 second 6 times. At this time released the button during the red color LED blinking. Then, ZWAVE Add / Remove operation is started",
|
|
65
|
+
"reset": "Hold the low button for 10 seconds.\n-Keep holding the button, then at 5 second,red LED of 3rd button is blinking 6 times, and keep holding.\nThe red LED blinking 6 times after 10 seconds. When you release your hand, the LED will stop blinking and return to the factory settings.\n*NOTES: Use this procedure only when the network primary controller is missing or otherwise inoperable",
|
|
66
|
+
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/3660/SmartSwitch_Product_Manual_KO.pdf"
|
|
67
|
+
}
|
|
68
|
+
}
|
package/package.json
CHANGED
|
@@ -1,6 +1,6 @@
|
|
|
1
1
|
{
|
|
2
2
|
"name": "@zwave-js/config",
|
|
3
|
-
"version": "11.0.0-beta.
|
|
3
|
+
"version": "11.0.0-beta.1",
|
|
4
4
|
"description": "zwave-js: configuration files",
|
|
5
5
|
"publishConfig": {
|
|
6
6
|
"access": "public"
|
|
@@ -58,8 +58,8 @@
|
|
|
58
58
|
"test:dirty": "node -r ../../maintenance/esbuild-register.js ../maintenance/src/resolveDirtyTests.ts --run"
|
|
59
59
|
},
|
|
60
60
|
"dependencies": {
|
|
61
|
-
"@zwave-js/core": "11.0.0-beta.
|
|
62
|
-
"@zwave-js/shared": "
|
|
61
|
+
"@zwave-js/core": "11.0.0-beta.1",
|
|
62
|
+
"@zwave-js/shared": "11.0.0-beta.1",
|
|
63
63
|
"alcalzone-shared": "^4.0.8",
|
|
64
64
|
"ansi-colors": "^4.1.3",
|
|
65
65
|
"fs-extra": "^10.1.0",
|
|
@@ -70,17 +70,17 @@
|
|
|
70
70
|
},
|
|
71
71
|
"devDependencies": {
|
|
72
72
|
"@esm2cjs/got": "^12.5.3",
|
|
73
|
-
"@microsoft/api-extractor": "
|
|
73
|
+
"@microsoft/api-extractor": "^7.35.0",
|
|
74
74
|
"@types/fs-extra": "^9.0.13",
|
|
75
75
|
"@types/js-levenshtein": "^1.1.1",
|
|
76
76
|
"@types/json-logic-js": "^2.0.2",
|
|
77
|
-
"@types/node": "^14.18.
|
|
77
|
+
"@types/node": "^14.18.47",
|
|
78
78
|
"@types/pegjs": "^0.10.3",
|
|
79
79
|
"@types/semver": "^7.3.13",
|
|
80
80
|
"@types/sinon": "^10.0.14",
|
|
81
81
|
"@types/xml2js": "^0.4.11",
|
|
82
82
|
"@types/yargs": "^17.0.24",
|
|
83
|
-
"@zwave-js/maintenance": "11.0.0-beta.
|
|
83
|
+
"@zwave-js/maintenance": "11.0.0-beta.1",
|
|
84
84
|
"ava": "^4.3.3",
|
|
85
85
|
"comment-json": "^4.2.3",
|
|
86
86
|
"del-cli": "^5.0.0",
|
|
@@ -91,7 +91,7 @@
|
|
|
91
91
|
"prettier": "^2.8.8",
|
|
92
92
|
"sinon": "^14.0.2",
|
|
93
93
|
"ts-pegjs": "^0.3.1",
|
|
94
|
-
"typescript": "
|
|
94
|
+
"typescript": "5.0.4",
|
|
95
95
|
"xml2js": "^0.5.0",
|
|
96
96
|
"yargs": "^17.7.2"
|
|
97
97
|
}
|
|
@@ -1,16 +0,0 @@
|
|
|
1
|
-
{
|
|
2
|
-
"manufacturer": "Shenzhen iSurpass Technology Co. , Ltd.",
|
|
3
|
-
"manufacturerId": "0x021c",
|
|
4
|
-
"label": "iLock",
|
|
5
|
-
"description": "Smart lock",
|
|
6
|
-
"devices": [
|
|
7
|
-
{
|
|
8
|
-
"productType": "0x634b",
|
|
9
|
-
"productId": "0x504c"
|
|
10
|
-
}
|
|
11
|
-
],
|
|
12
|
-
"firmwareVersion": {
|
|
13
|
-
"min": "0.0",
|
|
14
|
-
"max": "255.255"
|
|
15
|
-
}
|
|
16
|
-
}
|