@welldot/core 0.3.0 → 0.4.0-next.20261015.d7c7365
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/README.md +288 -75
- package/dist/index.cjs +2342 -44
- package/dist/index.cjs.map +1 -1
- package/dist/index.d.cts +14060 -4206
- package/dist/index.d.ts +14060 -4206
- package/dist/index.js +2220 -43
- package/dist/index.js.map +1 -1
- package/docs/schema/v2/well.schema.json +1043 -17
- package/docs/spec/v2/format-reference.md +507 -41
- package/docs/spec/v2/interoperability.md +44 -27
- package/docs/spec/v2/object-schemas.md +983 -113
- package/docs/spec/v2/overview.md +122 -6
- package/docs/spec/v2/water-quality.md +483 -0
- package/examples/README.md +83 -0
- package/examples/belem-pa-condominio-outorga.well +961 -0
- package/examples/belem-pa-monitoramento-posto.well +1141 -0
- package/examples/belem-pa-pirabas-abastecimento.well +1751 -0
- package/examples/belem-pa-poco-colmatado.well +496 -0
- package/examples/belem-pa-poco-raso-abandonado.well +388 -0
- package/examples/belem-pa-qualidade-agua-acida.well +895 -0
- package/examples/colatina-es-gnaisse-rural.well +1047 -0
- package/examples/coluna-mg-cristalino-abastecimento.well +1437 -0
- package/examples/estrela-doeste-sp-bauru-serra-geral.well +919 -0
- package/examples/extremoz-rn-barreiras-raso.well +623 -0
- package/examples/gastao-vidigal-sp-dados-inconsistentes.well +222 -0
- package/examples/index.json +452 -0
- package/examples/irece-ba-carste-bambui.well +861 -0
- package/examples/lagoa-santa-mg-carste-abastecimento.well +1087 -0
- package/examples/minas-novas-mg-cadastro-incompleto.well +157 -0
- package/examples/quixeramobim-ce-cristalino-salobro.well +989 -0
- package/examples/rinopolis-sp-estratigrafico-guarani.well +287 -0
- package/examples/santarem-pa-jorrante-alter-do-chao.well +554 -0
- package/examples/sao-gabriel-rs-cacimba.well +360 -0
- package/examples/sete-lagoas-mg-carste-industrial.well +410 -0
- package/examples/thumbs/belem-pa-condominio-outorga.svg +1 -0
- package/examples/thumbs/belem-pa-monitoramento-posto.svg +1 -0
- package/examples/thumbs/belem-pa-pirabas-abastecimento.svg +1 -0
- package/examples/thumbs/belem-pa-poco-colmatado.svg +1 -0
- package/examples/thumbs/belem-pa-poco-raso-abandonado.svg +1 -0
- package/examples/thumbs/belem-pa-qualidade-agua-acida.svg +1 -0
- package/examples/thumbs/colatina-es-gnaisse-rural.svg +1 -0
- package/examples/thumbs/coluna-mg-cristalino-abastecimento.svg +1 -0
- package/examples/thumbs/estrela-doeste-sp-bauru-serra-geral.svg +1 -0
- package/examples/thumbs/extremoz-rn-barreiras-raso.svg +1 -0
- package/examples/thumbs/gastao-vidigal-sp-dados-inconsistentes.svg +1 -0
- package/examples/thumbs/irece-ba-carste-bambui.svg +1 -0
- package/examples/thumbs/lagoa-santa-mg-carste-abastecimento.svg +1 -0
- package/examples/thumbs/minas-novas-mg-cadastro-incompleto.svg +1 -0
- package/examples/thumbs/quixeramobim-ce-cristalino-salobro.svg +1 -0
- package/examples/thumbs/rinopolis-sp-estratigrafico-guarani.svg +1 -0
- package/examples/thumbs/santarem-pa-jorrante-alter-do-chao.svg +1 -0
- package/examples/thumbs/sao-gabriel-rs-cacimba.svg +1 -0
- package/examples/thumbs/sete-lagoas-mg-carste-industrial.svg +1 -0
- package/package.json +5 -3
|
@@ -0,0 +1,623 @@
|
|
|
1
|
+
{
|
|
2
|
+
"$schema": "https://welldot.org/schema/v2/well.schema.json",
|
|
3
|
+
"version": 2,
|
|
4
|
+
"x-welldot-example": {
|
|
5
|
+
"illustrative": true,
|
|
6
|
+
"based_on": "https://siagasweb.sgb.gov.br/layout/detalhe.php?ponto=2600055664"
|
|
7
|
+
},
|
|
8
|
+
"well_type": "tubular",
|
|
9
|
+
"well_purpose": [
|
|
10
|
+
"production"
|
|
11
|
+
],
|
|
12
|
+
"name": "Poço P-07 — Captação Lagoa de Extremoz (Extremoz/RN)",
|
|
13
|
+
"well_driller": "Potiguar Sondagens Ltda.",
|
|
14
|
+
"construction_date": "1978-04-01",
|
|
15
|
+
"obs": "Poço raso (26 m) no Sistema Aquífero Dunas-Barreiras, à beira da Lagoa de Extremoz. Revestimento Nold de 8\" com dois filtros de aço inox espiralado e pré-filtro em todo o anular. Era jorrante quando foi perfurado; hoje o nível fica 3 m abaixo do terreno. Alta vazão com menos de 1 m de rebaixamento, mas aquífero livre e vulnerável: o nitrato das fossas da área urbana que cresceu em volta passou do limite em 2020.",
|
|
16
|
+
"well_id": [
|
|
17
|
+
{
|
|
18
|
+
"authority": "SAAE",
|
|
19
|
+
"id": "P-07",
|
|
20
|
+
"primary": true
|
|
21
|
+
},
|
|
22
|
+
{
|
|
23
|
+
"authority": "IGARN",
|
|
24
|
+
"id": "Cadastro 2004/0331"
|
|
25
|
+
}
|
|
26
|
+
],
|
|
27
|
+
"location": {
|
|
28
|
+
"lat": -5.70833,
|
|
29
|
+
"lng": -35.325,
|
|
30
|
+
"elevation": 9,
|
|
31
|
+
"properties": {
|
|
32
|
+
"crs": "EPSG:4326",
|
|
33
|
+
"lat_precision": 0.0003,
|
|
34
|
+
"lng_precision": 0.0003,
|
|
35
|
+
"elevation_datum": "x-imbituba",
|
|
36
|
+
"elevation_precision": 5,
|
|
37
|
+
"original_crs": "EPSG:31985"
|
|
38
|
+
}
|
|
39
|
+
},
|
|
40
|
+
"well_depth": 26,
|
|
41
|
+
"bore_hole": [
|
|
42
|
+
{
|
|
43
|
+
"from": 0,
|
|
44
|
+
"to": 26,
|
|
45
|
+
"diameter": 311,
|
|
46
|
+
"drilling_method": "rotary"
|
|
47
|
+
}
|
|
48
|
+
],
|
|
49
|
+
"well_case": [
|
|
50
|
+
{
|
|
51
|
+
"from": 0,
|
|
52
|
+
"to": 8,
|
|
53
|
+
"type": "carbon_steel",
|
|
54
|
+
"diameter": 219
|
|
55
|
+
},
|
|
56
|
+
{
|
|
57
|
+
"from": 11,
|
|
58
|
+
"to": 17,
|
|
59
|
+
"type": "carbon_steel",
|
|
60
|
+
"diameter": 219
|
|
61
|
+
}
|
|
62
|
+
],
|
|
63
|
+
"reduction": [],
|
|
64
|
+
"well_screen": [
|
|
65
|
+
{
|
|
66
|
+
"from": 8,
|
|
67
|
+
"to": 11,
|
|
68
|
+
"type": "stainless_steel",
|
|
69
|
+
"diameter": 219,
|
|
70
|
+
"screen_slot": 0.75,
|
|
71
|
+
"slot_type": "continuous_slot"
|
|
72
|
+
},
|
|
73
|
+
{
|
|
74
|
+
"from": 17,
|
|
75
|
+
"to": 26,
|
|
76
|
+
"type": "stainless_steel",
|
|
77
|
+
"diameter": 219,
|
|
78
|
+
"screen_slot": 0.75,
|
|
79
|
+
"slot_type": "continuous_slot"
|
|
80
|
+
}
|
|
81
|
+
],
|
|
82
|
+
"surface_case": [],
|
|
83
|
+
"hole_fill": [
|
|
84
|
+
{
|
|
85
|
+
"from": 0,
|
|
86
|
+
"to": 5,
|
|
87
|
+
"type": "seal",
|
|
88
|
+
"diameter": 311,
|
|
89
|
+
"description": "Cimentação do espaço anular"
|
|
90
|
+
},
|
|
91
|
+
{
|
|
92
|
+
"from": 5,
|
|
93
|
+
"to": 26,
|
|
94
|
+
"type": "gravel_pack",
|
|
95
|
+
"diameter": 311,
|
|
96
|
+
"description": "Pré-filtro de areia grossa selecionada"
|
|
97
|
+
}
|
|
98
|
+
],
|
|
99
|
+
"lithology": [
|
|
100
|
+
{
|
|
101
|
+
"from": 0,
|
|
102
|
+
"to": 1.5,
|
|
103
|
+
"description": "Solo areno-argiloso escuro",
|
|
104
|
+
"color": "#6e5a45",
|
|
105
|
+
"texture": {
|
|
106
|
+
"code": 612,
|
|
107
|
+
"vocabulary": "fgdc"
|
|
108
|
+
},
|
|
109
|
+
"geologic_unit": "Cobertura",
|
|
110
|
+
"aquifer_unit": "Zona não saturada"
|
|
111
|
+
},
|
|
112
|
+
{
|
|
113
|
+
"from": 1.5,
|
|
114
|
+
"to": 6,
|
|
115
|
+
"description": "Arenito médio a grosso, pouco argiloso, creme-amarelado",
|
|
116
|
+
"color": "#e2cf9a",
|
|
117
|
+
"texture": {
|
|
118
|
+
"code": 607,
|
|
119
|
+
"vocabulary": "fgdc"
|
|
120
|
+
},
|
|
121
|
+
"geologic_unit": "Grupo Barreiras",
|
|
122
|
+
"aquifer_unit": "Sistema Aquífero Dunas-Barreiras"
|
|
123
|
+
},
|
|
124
|
+
{
|
|
125
|
+
"from": 6,
|
|
126
|
+
"to": 8.5,
|
|
127
|
+
"description": "Arenito muito fino a médio, argiloso, creme",
|
|
128
|
+
"color": "#d9c7a0",
|
|
129
|
+
"texture": {
|
|
130
|
+
"code": 612,
|
|
131
|
+
"vocabulary": "fgdc"
|
|
132
|
+
},
|
|
133
|
+
"geologic_unit": "Grupo Barreiras",
|
|
134
|
+
"aquifer_unit": "Sistema Aquífero Dunas-Barreiras"
|
|
135
|
+
},
|
|
136
|
+
{
|
|
137
|
+
"from": 8.5,
|
|
138
|
+
"to": 12.5,
|
|
139
|
+
"description": "Arenito grosso, claro",
|
|
140
|
+
"color": "#ece3c8",
|
|
141
|
+
"texture": {
|
|
142
|
+
"code": 607,
|
|
143
|
+
"vocabulary": "fgdc"
|
|
144
|
+
},
|
|
145
|
+
"geologic_unit": "Grupo Barreiras",
|
|
146
|
+
"aquifer_unit": "Sistema Aquífero Dunas-Barreiras"
|
|
147
|
+
},
|
|
148
|
+
{
|
|
149
|
+
"from": 12.5,
|
|
150
|
+
"to": 14.5,
|
|
151
|
+
"description": "Argilito compacto, marrom",
|
|
152
|
+
"color": "#8a5a3c",
|
|
153
|
+
"texture": {
|
|
154
|
+
"code": 620,
|
|
155
|
+
"vocabulary": "fgdc"
|
|
156
|
+
},
|
|
157
|
+
"geologic_unit": "Grupo Barreiras",
|
|
158
|
+
"aquifer_unit": "Aquitarde local"
|
|
159
|
+
},
|
|
160
|
+
{
|
|
161
|
+
"from": 14.5,
|
|
162
|
+
"to": 20.5,
|
|
163
|
+
"description": "Arenito fino, pouco argiloso, amarelado",
|
|
164
|
+
"color": "#dcc27a",
|
|
165
|
+
"texture": {
|
|
166
|
+
"code": 608,
|
|
167
|
+
"vocabulary": "fgdc"
|
|
168
|
+
},
|
|
169
|
+
"geologic_unit": "Grupo Barreiras",
|
|
170
|
+
"aquifer_unit": "Sistema Aquífero Dunas-Barreiras"
|
|
171
|
+
},
|
|
172
|
+
{
|
|
173
|
+
"from": 20.5,
|
|
174
|
+
"to": 26,
|
|
175
|
+
"description": "Arenito médio a grosso, compacto, esbranquiçado",
|
|
176
|
+
"color": "#efe9da",
|
|
177
|
+
"texture": {
|
|
178
|
+
"code": 607,
|
|
179
|
+
"vocabulary": "fgdc"
|
|
180
|
+
},
|
|
181
|
+
"geologic_unit": "Grupo Barreiras",
|
|
182
|
+
"aquifer_unit": "Sistema Aquífero Dunas-Barreiras"
|
|
183
|
+
}
|
|
184
|
+
],
|
|
185
|
+
"fractures": [],
|
|
186
|
+
"caves": [],
|
|
187
|
+
"hydrodynamic_events": [
|
|
188
|
+
{
|
|
189
|
+
"id": "evt-01",
|
|
190
|
+
"type": "constant_rate",
|
|
191
|
+
"datetime": "1978-04-01T07:00:00-03:00",
|
|
192
|
+
"operator": "Potiguar Sondagens Ltda.",
|
|
193
|
+
"static_level": -0.01,
|
|
194
|
+
"notes": "Poço jorrante no teste (carga 1 cm acima do terreno). Ficha antiga: só o nível dinâmico final e a vazão.",
|
|
195
|
+
"steps": [
|
|
196
|
+
{
|
|
197
|
+
"rate": 36,
|
|
198
|
+
"duration": 1440,
|
|
199
|
+
"readings": [
|
|
200
|
+
{
|
|
201
|
+
"elapsed": 1440,
|
|
202
|
+
"depth": 0.8
|
|
203
|
+
}
|
|
204
|
+
]
|
|
205
|
+
}
|
|
206
|
+
]
|
|
207
|
+
},
|
|
208
|
+
{
|
|
209
|
+
"id": "evt-02",
|
|
210
|
+
"type": "spot_measurement",
|
|
211
|
+
"datetime": "2006-09-12T07:00:00-03:00",
|
|
212
|
+
"operator": "SAAE — Operação",
|
|
213
|
+
"static_level": 1.65,
|
|
214
|
+
"static_level_precision": 0.01,
|
|
215
|
+
"measurement_method": "electric_probe"
|
|
216
|
+
},
|
|
217
|
+
{
|
|
218
|
+
"id": "evt-03",
|
|
219
|
+
"type": "spot_measurement",
|
|
220
|
+
"datetime": "2025-04-08T07:00:00-03:00",
|
|
221
|
+
"operator": "SAAE — Operação",
|
|
222
|
+
"static_level": 3.05,
|
|
223
|
+
"static_level_precision": 0.01,
|
|
224
|
+
"measurement_method": "electric_probe",
|
|
225
|
+
"notes": "Rebaixamento de 3 m em 47 anos, com dezenas de poços novos no entorno."
|
|
226
|
+
}
|
|
227
|
+
],
|
|
228
|
+
"cement_pad": {
|
|
229
|
+
"type": "concrete",
|
|
230
|
+
"width": 1,
|
|
231
|
+
"thickness": 0.15,
|
|
232
|
+
"length": 1
|
|
233
|
+
},
|
|
234
|
+
"aquifer_analysis": [
|
|
235
|
+
{
|
|
236
|
+
"id": "an-1978",
|
|
237
|
+
"datetime": "1978-04-03T10:00:00-03:00",
|
|
238
|
+
"source_event_ids": [
|
|
239
|
+
"evt-01"
|
|
240
|
+
],
|
|
241
|
+
"method": "x-specific_capacity",
|
|
242
|
+
"static_level": -0.01,
|
|
243
|
+
"static_level_source_id": "evt-01",
|
|
244
|
+
"dynamic_level": 0.8,
|
|
245
|
+
"flow_rate": 36,
|
|
246
|
+
"specific_capacity": 44.44
|
|
247
|
+
}
|
|
248
|
+
],
|
|
249
|
+
"pump_installations": [
|
|
250
|
+
{
|
|
251
|
+
"id": "pump-2009",
|
|
252
|
+
"installed_at": "2009-06-16T09:00:00-03:00",
|
|
253
|
+
"installed_by": "SAAE — Manutenção",
|
|
254
|
+
"type": "submersible",
|
|
255
|
+
"power_source": "grid",
|
|
256
|
+
"manufacturer": "Ebara",
|
|
257
|
+
"model": "BHS 815-3",
|
|
258
|
+
"intake_depth": 7,
|
|
259
|
+
"rated_flow_rate": 30,
|
|
260
|
+
"rated_head": 35,
|
|
261
|
+
"rated_power": 5.5,
|
|
262
|
+
"stages": 3,
|
|
263
|
+
"riser_diameter": 75,
|
|
264
|
+
"riser_material": "galvanized_steel",
|
|
265
|
+
"check_valve": true,
|
|
266
|
+
"electrical": {
|
|
267
|
+
"voltage": 380,
|
|
268
|
+
"phases": 3,
|
|
269
|
+
"cable_section": 6,
|
|
270
|
+
"cable_length": 20
|
|
271
|
+
},
|
|
272
|
+
"notes": "Sucção acima do primeiro filtro."
|
|
273
|
+
}
|
|
274
|
+
],
|
|
275
|
+
"operating_regime": [
|
|
276
|
+
{
|
|
277
|
+
"id": "reg-2009",
|
|
278
|
+
"effective_from": "2009-06-16T09:00:00-03:00",
|
|
279
|
+
"flow_rate": 30,
|
|
280
|
+
"daily_operating_time": 16,
|
|
281
|
+
"days_per_week": 7
|
|
282
|
+
},
|
|
283
|
+
{
|
|
284
|
+
"id": "reg-2021",
|
|
285
|
+
"effective_from": "2021-02-01T00:00:00-03:00",
|
|
286
|
+
"flow_rate": 30,
|
|
287
|
+
"daily_operating_time": 10,
|
|
288
|
+
"days_per_week": 7,
|
|
289
|
+
"notes": "Menos horas de bombeamento: a água do poço é diluída com a de um poço profundo antes da distribuição."
|
|
290
|
+
}
|
|
291
|
+
],
|
|
292
|
+
"water_samples": [
|
|
293
|
+
{
|
|
294
|
+
"id": "am-1998",
|
|
295
|
+
"datetime": "1998-03-17T08:00:00-03:00",
|
|
296
|
+
"sample_type": "routine",
|
|
297
|
+
"sampling_method": "pump_discharge",
|
|
298
|
+
"sampling_point": {
|
|
299
|
+
"type": "pump_discharge"
|
|
300
|
+
},
|
|
301
|
+
"collected_by": "SAAE — Controle de Qualidade",
|
|
302
|
+
"laboratory": {
|
|
303
|
+
"name": "Laboratório de Saneamento do RN",
|
|
304
|
+
"report_number": "LS-98/0331"
|
|
305
|
+
},
|
|
306
|
+
"results": [
|
|
307
|
+
{
|
|
308
|
+
"parameter": {
|
|
309
|
+
"code": "ph",
|
|
310
|
+
"vocabulary": "welldot"
|
|
311
|
+
},
|
|
312
|
+
"value": 5.4,
|
|
313
|
+
"measured_in": "field"
|
|
314
|
+
},
|
|
315
|
+
{
|
|
316
|
+
"parameter": {
|
|
317
|
+
"code": "specific_conductance",
|
|
318
|
+
"vocabulary": "welldot"
|
|
319
|
+
},
|
|
320
|
+
"value": 168,
|
|
321
|
+
"measured_in": "field"
|
|
322
|
+
},
|
|
323
|
+
{
|
|
324
|
+
"parameter": {
|
|
325
|
+
"code": "chloride",
|
|
326
|
+
"vocabulary": "welldot"
|
|
327
|
+
},
|
|
328
|
+
"value": 31,
|
|
329
|
+
"measured_in": "lab"
|
|
330
|
+
},
|
|
331
|
+
{
|
|
332
|
+
"parameter": {
|
|
333
|
+
"code": "nitrate_as_n",
|
|
334
|
+
"vocabulary": "welldot"
|
|
335
|
+
},
|
|
336
|
+
"value": 2.1,
|
|
337
|
+
"measured_in": "lab"
|
|
338
|
+
},
|
|
339
|
+
{
|
|
340
|
+
"parameter": {
|
|
341
|
+
"code": "total_coliforms",
|
|
342
|
+
"vocabulary": "welldot"
|
|
343
|
+
},
|
|
344
|
+
"measured_in": "lab",
|
|
345
|
+
"presence": false,
|
|
346
|
+
"method": "SMEWW 9223 B"
|
|
347
|
+
}
|
|
348
|
+
]
|
|
349
|
+
},
|
|
350
|
+
{
|
|
351
|
+
"id": "am-2006",
|
|
352
|
+
"datetime": "2006-09-12T08:00:00-03:00",
|
|
353
|
+
"sample_type": "routine",
|
|
354
|
+
"sampling_method": "pump_discharge",
|
|
355
|
+
"sampling_point": {
|
|
356
|
+
"type": "pump_discharge"
|
|
357
|
+
},
|
|
358
|
+
"collected_by": "SAAE — Controle de Qualidade",
|
|
359
|
+
"laboratory": {
|
|
360
|
+
"name": "Laboratório de Saneamento do RN",
|
|
361
|
+
"report_number": "LS-06/1127"
|
|
362
|
+
},
|
|
363
|
+
"results": [
|
|
364
|
+
{
|
|
365
|
+
"parameter": {
|
|
366
|
+
"code": "ph",
|
|
367
|
+
"vocabulary": "welldot"
|
|
368
|
+
},
|
|
369
|
+
"value": 5.4,
|
|
370
|
+
"measured_in": "field"
|
|
371
|
+
},
|
|
372
|
+
{
|
|
373
|
+
"parameter": {
|
|
374
|
+
"code": "specific_conductance",
|
|
375
|
+
"vocabulary": "welldot"
|
|
376
|
+
},
|
|
377
|
+
"value": 214,
|
|
378
|
+
"measured_in": "field"
|
|
379
|
+
},
|
|
380
|
+
{
|
|
381
|
+
"parameter": {
|
|
382
|
+
"code": "chloride",
|
|
383
|
+
"vocabulary": "welldot"
|
|
384
|
+
},
|
|
385
|
+
"value": 44,
|
|
386
|
+
"measured_in": "lab"
|
|
387
|
+
},
|
|
388
|
+
{
|
|
389
|
+
"parameter": {
|
|
390
|
+
"code": "nitrate_as_n",
|
|
391
|
+
"vocabulary": "welldot"
|
|
392
|
+
},
|
|
393
|
+
"value": 5.4,
|
|
394
|
+
"measured_in": "lab"
|
|
395
|
+
},
|
|
396
|
+
{
|
|
397
|
+
"parameter": {
|
|
398
|
+
"code": "total_coliforms",
|
|
399
|
+
"vocabulary": "welldot"
|
|
400
|
+
},
|
|
401
|
+
"measured_in": "lab",
|
|
402
|
+
"presence": false,
|
|
403
|
+
"method": "SMEWW 9223 B"
|
|
404
|
+
}
|
|
405
|
+
]
|
|
406
|
+
},
|
|
407
|
+
{
|
|
408
|
+
"id": "am-2014",
|
|
409
|
+
"datetime": "2014-05-20T08:00:00-03:00",
|
|
410
|
+
"sample_type": "routine",
|
|
411
|
+
"sampling_method": "pump_discharge",
|
|
412
|
+
"sampling_point": {
|
|
413
|
+
"type": "pump_discharge"
|
|
414
|
+
},
|
|
415
|
+
"collected_by": "SAAE — Controle de Qualidade",
|
|
416
|
+
"laboratory": {
|
|
417
|
+
"name": "Laboratório de Saneamento do RN",
|
|
418
|
+
"report_number": "LS-14/0802"
|
|
419
|
+
},
|
|
420
|
+
"results": [
|
|
421
|
+
{
|
|
422
|
+
"parameter": {
|
|
423
|
+
"code": "ph",
|
|
424
|
+
"vocabulary": "welldot"
|
|
425
|
+
},
|
|
426
|
+
"value": 5.4,
|
|
427
|
+
"measured_in": "field"
|
|
428
|
+
},
|
|
429
|
+
{
|
|
430
|
+
"parameter": {
|
|
431
|
+
"code": "specific_conductance",
|
|
432
|
+
"vocabulary": "welldot"
|
|
433
|
+
},
|
|
434
|
+
"value": 268,
|
|
435
|
+
"measured_in": "field"
|
|
436
|
+
},
|
|
437
|
+
{
|
|
438
|
+
"parameter": {
|
|
439
|
+
"code": "chloride",
|
|
440
|
+
"vocabulary": "welldot"
|
|
441
|
+
},
|
|
442
|
+
"value": 58,
|
|
443
|
+
"measured_in": "lab"
|
|
444
|
+
},
|
|
445
|
+
{
|
|
446
|
+
"parameter": {
|
|
447
|
+
"code": "nitrate_as_n",
|
|
448
|
+
"vocabulary": "welldot"
|
|
449
|
+
},
|
|
450
|
+
"value": 8.9,
|
|
451
|
+
"measured_in": "lab"
|
|
452
|
+
},
|
|
453
|
+
{
|
|
454
|
+
"parameter": {
|
|
455
|
+
"code": "total_coliforms",
|
|
456
|
+
"vocabulary": "welldot"
|
|
457
|
+
},
|
|
458
|
+
"measured_in": "lab",
|
|
459
|
+
"presence": false,
|
|
460
|
+
"method": "SMEWW 9223 B"
|
|
461
|
+
}
|
|
462
|
+
]
|
|
463
|
+
},
|
|
464
|
+
{
|
|
465
|
+
"id": "am-2020",
|
|
466
|
+
"datetime": "2020-10-06T08:00:00-03:00",
|
|
467
|
+
"sample_type": "routine",
|
|
468
|
+
"sampling_method": "pump_discharge",
|
|
469
|
+
"sampling_point": {
|
|
470
|
+
"type": "pump_discharge"
|
|
471
|
+
},
|
|
472
|
+
"collected_by": "SAAE — Controle de Qualidade",
|
|
473
|
+
"laboratory": {
|
|
474
|
+
"name": "Laboratório de Saneamento do RN",
|
|
475
|
+
"report_number": "LS-20/1546"
|
|
476
|
+
},
|
|
477
|
+
"results": [
|
|
478
|
+
{
|
|
479
|
+
"parameter": {
|
|
480
|
+
"code": "ph",
|
|
481
|
+
"vocabulary": "welldot"
|
|
482
|
+
},
|
|
483
|
+
"value": 5.4,
|
|
484
|
+
"measured_in": "field"
|
|
485
|
+
},
|
|
486
|
+
{
|
|
487
|
+
"parameter": {
|
|
488
|
+
"code": "specific_conductance",
|
|
489
|
+
"vocabulary": "welldot"
|
|
490
|
+
},
|
|
491
|
+
"value": 301,
|
|
492
|
+
"measured_in": "field"
|
|
493
|
+
},
|
|
494
|
+
{
|
|
495
|
+
"parameter": {
|
|
496
|
+
"code": "chloride",
|
|
497
|
+
"vocabulary": "welldot"
|
|
498
|
+
},
|
|
499
|
+
"value": 66,
|
|
500
|
+
"measured_in": "lab"
|
|
501
|
+
},
|
|
502
|
+
{
|
|
503
|
+
"parameter": {
|
|
504
|
+
"code": "nitrate_as_n",
|
|
505
|
+
"vocabulary": "welldot"
|
|
506
|
+
},
|
|
507
|
+
"value": 11.2,
|
|
508
|
+
"measured_in": "lab"
|
|
509
|
+
},
|
|
510
|
+
{
|
|
511
|
+
"parameter": {
|
|
512
|
+
"code": "total_coliforms",
|
|
513
|
+
"vocabulary": "welldot"
|
|
514
|
+
},
|
|
515
|
+
"measured_in": "lab",
|
|
516
|
+
"presence": false,
|
|
517
|
+
"method": "SMEWW 9223 B"
|
|
518
|
+
}
|
|
519
|
+
]
|
|
520
|
+
},
|
|
521
|
+
{
|
|
522
|
+
"id": "am-2025",
|
|
523
|
+
"datetime": "2025-04-08T08:00:00-03:00",
|
|
524
|
+
"sample_type": "routine",
|
|
525
|
+
"sampling_method": "pump_discharge",
|
|
526
|
+
"sampling_point": {
|
|
527
|
+
"type": "pump_discharge"
|
|
528
|
+
},
|
|
529
|
+
"collected_by": "SAAE — Controle de Qualidade",
|
|
530
|
+
"laboratory": {
|
|
531
|
+
"name": "Laboratório de Saneamento do RN",
|
|
532
|
+
"report_number": "LS-25/0477"
|
|
533
|
+
},
|
|
534
|
+
"results": [
|
|
535
|
+
{
|
|
536
|
+
"parameter": {
|
|
537
|
+
"code": "ph",
|
|
538
|
+
"vocabulary": "welldot"
|
|
539
|
+
},
|
|
540
|
+
"value": 5.4,
|
|
541
|
+
"measured_in": "field"
|
|
542
|
+
},
|
|
543
|
+
{
|
|
544
|
+
"parameter": {
|
|
545
|
+
"code": "specific_conductance",
|
|
546
|
+
"vocabulary": "welldot"
|
|
547
|
+
},
|
|
548
|
+
"value": 322,
|
|
549
|
+
"measured_in": "field"
|
|
550
|
+
},
|
|
551
|
+
{
|
|
552
|
+
"parameter": {
|
|
553
|
+
"code": "chloride",
|
|
554
|
+
"vocabulary": "welldot"
|
|
555
|
+
},
|
|
556
|
+
"value": 71,
|
|
557
|
+
"measured_in": "lab"
|
|
558
|
+
},
|
|
559
|
+
{
|
|
560
|
+
"parameter": {
|
|
561
|
+
"code": "nitrate_as_n",
|
|
562
|
+
"vocabulary": "welldot"
|
|
563
|
+
},
|
|
564
|
+
"value": 12.6,
|
|
565
|
+
"measured_in": "lab"
|
|
566
|
+
},
|
|
567
|
+
{
|
|
568
|
+
"parameter": {
|
|
569
|
+
"code": "total_coliforms",
|
|
570
|
+
"vocabulary": "welldot"
|
|
571
|
+
},
|
|
572
|
+
"measured_in": "lab",
|
|
573
|
+
"presence": false,
|
|
574
|
+
"method": "SMEWW 9223 B"
|
|
575
|
+
}
|
|
576
|
+
]
|
|
577
|
+
}
|
|
578
|
+
],
|
|
579
|
+
"history_logs": [
|
|
580
|
+
{
|
|
581
|
+
"id": "log-01",
|
|
582
|
+
"datetime": "1978-04-03T09:00:00-03:00",
|
|
583
|
+
"category": "status_change",
|
|
584
|
+
"status": "active",
|
|
585
|
+
"description": "Poço entra em operação, inicialmente por surgência e bomba de superfície.",
|
|
586
|
+
"hydrodynamic_event_ids": [
|
|
587
|
+
"evt-01"
|
|
588
|
+
]
|
|
589
|
+
},
|
|
590
|
+
{
|
|
591
|
+
"id": "log-02",
|
|
592
|
+
"datetime": "2009-06-16T09:00:00-03:00",
|
|
593
|
+
"category": "maintenance",
|
|
594
|
+
"maintenance_type": "pump_service",
|
|
595
|
+
"pump_installation_id": "pump-2009",
|
|
596
|
+
"description": "Bomba de superfície substituída por bomba submersa: o poço deixou de jorrar.",
|
|
597
|
+
"author": "SAAE — Manutenção"
|
|
598
|
+
},
|
|
599
|
+
{
|
|
600
|
+
"id": "log-03",
|
|
601
|
+
"datetime": "2020-10-20T09:00:00-03:00",
|
|
602
|
+
"category": "incident",
|
|
603
|
+
"severity": "high",
|
|
604
|
+
"description": "Nitrato acima de 10 mg/L N (valor máximo permitido). Diluição com água de poço profundo a partir de fevereiro de 2021.",
|
|
605
|
+
"sample_ids": [
|
|
606
|
+
"am-2020"
|
|
607
|
+
]
|
|
608
|
+
},
|
|
609
|
+
{
|
|
610
|
+
"id": "log-04",
|
|
611
|
+
"datetime": "2025-04-08T11:00:00-03:00",
|
|
612
|
+
"category": "inspection",
|
|
613
|
+
"severity": "high",
|
|
614
|
+
"description": "Nitrato segue subindo (12,6 mg/L N). Recomendada a substituição do poço por captação no Barreiras profundo, isolada por cimentação.",
|
|
615
|
+
"hydrodynamic_event_ids": [
|
|
616
|
+
"evt-03"
|
|
617
|
+
],
|
|
618
|
+
"sample_ids": [
|
|
619
|
+
"am-2025"
|
|
620
|
+
]
|
|
621
|
+
}
|
|
622
|
+
]
|
|