@wandelbots/nova-api 25.8.0-dev.14 → 25.8.0-dev.15
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/package.json +1 -1
- package/v2/api.d.ts +131 -84
- package/v2/api.js +43 -43
- package/v2/api.js.map +1 -1
- package/v2/api.ts +131 -80
package/v2/api.d.ts
CHANGED
|
@@ -342,7 +342,7 @@ export declare const BoxBoxTypeEnum: {
|
|
|
342
342
|
};
|
|
343
343
|
export type BoxBoxTypeEnum = typeof BoxBoxTypeEnum[keyof typeof BoxBoxTypeEnum];
|
|
344
344
|
/**
|
|
345
|
-
* PROFINET BUS
|
|
345
|
+
* PROFINET BUS inputs/outputs service configuration.
|
|
346
346
|
* @export
|
|
347
347
|
* @interface BusIOProfinet
|
|
348
348
|
*/
|
|
@@ -354,19 +354,19 @@ export interface BusIOProfinet {
|
|
|
354
354
|
*/
|
|
355
355
|
'bus_type'?: BusIOProfinetBusTypeEnum;
|
|
356
356
|
/**
|
|
357
|
-
*
|
|
357
|
+
* Content of Configuration XML file for PROFINET device, typically known as PND_IOD.xml. Leave empty for the default configuration. Refer to the official PROFINET driver documentation for further information.
|
|
358
358
|
* @type {string}
|
|
359
359
|
* @memberof BusIOProfinet
|
|
360
360
|
*/
|
|
361
361
|
'config_file_content'?: string;
|
|
362
362
|
/**
|
|
363
|
-
*
|
|
363
|
+
* Used to enable IP communication through the same physical interface while PN Driver is running.
|
|
364
364
|
* @type {BusIOProfinetNetwork}
|
|
365
365
|
* @memberof BusIOProfinet
|
|
366
366
|
*/
|
|
367
367
|
'network_config'?: BusIOProfinetNetwork;
|
|
368
368
|
/**
|
|
369
|
-
* MAC address
|
|
369
|
+
* MAC address of the physical ethernet interface that you want to use for PROFINET communication.
|
|
370
370
|
* @type {string}
|
|
371
371
|
* @memberof BusIOProfinet
|
|
372
372
|
*/
|
|
@@ -383,7 +383,7 @@ export declare const BusIOProfinetBusTypeEnum: {
|
|
|
383
383
|
};
|
|
384
384
|
export type BusIOProfinetBusTypeEnum = typeof BusIOProfinetBusTypeEnum[keyof typeof BusIOProfinetBusTypeEnum];
|
|
385
385
|
/**
|
|
386
|
-
*
|
|
386
|
+
* Current default route configuration of your NOVA instance. The default route is a setting that tells data where to go if there isn’t a specific path already known for its destination. Usually this will be the path to your router, enabling accessing the internet. On Linux, use `ip route show` to view your default routes and match the output `default via <gateway> dev <interface> ...` to get your gateway and interface.
|
|
387
387
|
* @export
|
|
388
388
|
* @interface BusIOProfinetDefaultRoute
|
|
389
389
|
*/
|
|
@@ -402,25 +402,25 @@ export interface BusIOProfinetDefaultRoute {
|
|
|
402
402
|
'interface': string;
|
|
403
403
|
}
|
|
404
404
|
/**
|
|
405
|
-
* Network configuration
|
|
405
|
+
* Network configuration or IPv4 record of the virtual ethernet interface (pnio1) created by the PROFINET driver. The IPv4 record is used in combination with the Name of Station (NoS) to identify your device in the PROFINET network. The `ip_config` will be used as IPv4 record if no REMA XML file is already present on your machine and no `rema_xml_content` is provided.
|
|
406
406
|
* @export
|
|
407
407
|
* @interface BusIOProfinetIpConfig
|
|
408
408
|
*/
|
|
409
409
|
export interface BusIOProfinetIpConfig {
|
|
410
410
|
/**
|
|
411
|
-
* IP address for the
|
|
411
|
+
* IP address for the device\'s virtual ethernet interface (pnio1).
|
|
412
412
|
* @type {string}
|
|
413
413
|
* @memberof BusIOProfinetIpConfig
|
|
414
414
|
*/
|
|
415
415
|
'ip': string;
|
|
416
416
|
/**
|
|
417
|
-
* Network mask for the
|
|
417
|
+
* Network mask for the device\'s virtual ethernet interface (pnio1).
|
|
418
418
|
* @type {string}
|
|
419
419
|
* @memberof BusIOProfinetIpConfig
|
|
420
420
|
*/
|
|
421
421
|
'netmask': string;
|
|
422
422
|
/**
|
|
423
|
-
* Gateway for the
|
|
423
|
+
* Gateway for connections to other devices outside of the virtual ethernet interface\'s subnet.
|
|
424
424
|
* @type {string}
|
|
425
425
|
* @memberof BusIOProfinetIpConfig
|
|
426
426
|
*/
|
|
@@ -433,7 +433,7 @@ export interface BusIOProfinetIpConfig {
|
|
|
433
433
|
*/
|
|
434
434
|
export interface BusIOProfinetNetwork {
|
|
435
435
|
/**
|
|
436
|
-
* Name of the PROFINET device.
|
|
436
|
+
* Name of Station (NoS) of the PROFINET device. The NoS is used in combination with IPv4 record to identify your device in the PROFINET network. The `device_name` will be used as NoS if no REMA XML file is already present on your machine and no `rema_xml_content` is provided.
|
|
437
437
|
* @type {string}
|
|
438
438
|
* @memberof BusIOProfinetNetwork
|
|
439
439
|
*/
|
|
@@ -445,14 +445,14 @@ export interface BusIOProfinetNetwork {
|
|
|
445
445
|
*/
|
|
446
446
|
'ip_config'?: BusIOProfinetIpConfig;
|
|
447
447
|
/**
|
|
448
|
-
* Content of the PROFINET REMA XML file.
|
|
448
|
+
* Content of the PROFINET REMA XML file. Is used when PROFINET service is added for the first time to create the REMA XML file that holds data to be kept for the next session. Stores information like IP address, Name of Station (NoS) and hardware configuration. If you use a PROFINET controller to assign an IP address to the PROFINET device, this information will be written to the REMA XML file. Refer to the PDF version of the \"PN Driver I/O Base programming interface\" documentation for more information and an example REMA file.
|
|
449
449
|
* @type {string}
|
|
450
450
|
* @memberof BusIOProfinetNetwork
|
|
451
451
|
*/
|
|
452
452
|
'rema_xml_content'?: string;
|
|
453
453
|
}
|
|
454
454
|
/**
|
|
455
|
-
* Virtual PROFINET BUS
|
|
455
|
+
* Virtual PROFINET BUS inputs/outputs service configuration.
|
|
456
456
|
* @export
|
|
457
457
|
* @interface BusIOProfinetVirtual
|
|
458
458
|
*/
|
|
@@ -465,7 +465,7 @@ export interface BusIOProfinetVirtual {
|
|
|
465
465
|
'bus_type'?: BusIOProfinetVirtualBusTypeEnum;
|
|
466
466
|
}
|
|
467
467
|
export declare const BusIOProfinetVirtualBusTypeEnum: {
|
|
468
|
-
readonly
|
|
468
|
+
readonly ProfinetVirtual: "profinet_virtual";
|
|
469
469
|
};
|
|
470
470
|
export type BusIOProfinetVirtualBusTypeEnum = typeof BusIOProfinetVirtualBusTypeEnum[keyof typeof BusIOProfinetVirtualBusTypeEnum];
|
|
471
471
|
/**
|
|
@@ -490,7 +490,7 @@ export interface BusIOsState {
|
|
|
490
490
|
*/
|
|
491
491
|
'state': BusIOsStateEnum;
|
|
492
492
|
/**
|
|
493
|
-
* A message providing additional information on the input/output, e.g. BUS service status, encountered errors. May be empty if no additional information is available.
|
|
493
|
+
* A message providing additional information on the input/output service, e.g. BUS service status, encountered errors. May be empty if no additional information is available.
|
|
494
494
|
* @type {string}
|
|
495
495
|
* @memberof BusIOsState
|
|
496
496
|
*/
|
|
@@ -1797,6 +1797,55 @@ export interface IODescription {
|
|
|
1797
1797
|
*/
|
|
1798
1798
|
'max'?: IODescriptionMin;
|
|
1799
1799
|
}
|
|
1800
|
+
/**
|
|
1801
|
+
*
|
|
1802
|
+
* @export
|
|
1803
|
+
* @interface IODescription2
|
|
1804
|
+
*/
|
|
1805
|
+
export interface IODescription2 {
|
|
1806
|
+
/**
|
|
1807
|
+
* Unique identifier of the input/output.
|
|
1808
|
+
* @type {string}
|
|
1809
|
+
* @memberof IODescription2
|
|
1810
|
+
*/
|
|
1811
|
+
'io': string;
|
|
1812
|
+
/**
|
|
1813
|
+
* Descriptive name of the input/output. Customize it using the respective BUS service, e.g. [addProfinetIO](addProfinetIO) for PROFINET service.
|
|
1814
|
+
* @type {string}
|
|
1815
|
+
* @memberof IODescription2
|
|
1816
|
+
*/
|
|
1817
|
+
'name': string;
|
|
1818
|
+
/**
|
|
1819
|
+
*
|
|
1820
|
+
* @type {IODirection}
|
|
1821
|
+
* @memberof IODescription2
|
|
1822
|
+
*/
|
|
1823
|
+
'direction': IODirection;
|
|
1824
|
+
/**
|
|
1825
|
+
*
|
|
1826
|
+
* @type {IOValueType}
|
|
1827
|
+
* @memberof IODescription2
|
|
1828
|
+
*/
|
|
1829
|
+
'value_type': IOValueType;
|
|
1830
|
+
/**
|
|
1831
|
+
*
|
|
1832
|
+
* @type {UnitType}
|
|
1833
|
+
* @memberof IODescription2
|
|
1834
|
+
*/
|
|
1835
|
+
'unit'?: UnitType;
|
|
1836
|
+
/**
|
|
1837
|
+
*
|
|
1838
|
+
* @type {IODescriptionMin}
|
|
1839
|
+
* @memberof IODescription2
|
|
1840
|
+
*/
|
|
1841
|
+
'min'?: IODescriptionMin;
|
|
1842
|
+
/**
|
|
1843
|
+
*
|
|
1844
|
+
* @type {IODescriptionMin}
|
|
1845
|
+
* @memberof IODescription2
|
|
1846
|
+
*/
|
|
1847
|
+
'max'?: IODescriptionMin;
|
|
1848
|
+
}
|
|
1800
1849
|
/**
|
|
1801
1850
|
* @type IODescriptionMin
|
|
1802
1851
|
* @export
|
|
@@ -3915,17 +3964,17 @@ export interface ProfinetDescription {
|
|
|
3915
3964
|
*/
|
|
3916
3965
|
'slots'?: Array<ProfinetSlotDescription>;
|
|
3917
3966
|
/**
|
|
3918
|
-
* Name of the PROFINET device
|
|
3967
|
+
* Name of Station (NoS) of the PROFINET device. The NoS is used in combination with IPv4 record to identify your device in the PROFINET network. The `device_name` will be used as NoS if no REMA XML file is already present on your NOVA instance and no `rema_xml_content` is provided.
|
|
3919
3968
|
* @type {string}
|
|
3920
3969
|
* @memberof ProfinetDescription
|
|
3921
3970
|
*/
|
|
3922
3971
|
'device_name'?: string;
|
|
3923
3972
|
/**
|
|
3924
|
-
*
|
|
3925
|
-
* @type {
|
|
3973
|
+
*
|
|
3974
|
+
* @type {BusIOProfinetIpConfig}
|
|
3926
3975
|
* @memberof ProfinetDescription
|
|
3927
3976
|
*/
|
|
3928
|
-
'
|
|
3977
|
+
'ip_config'?: BusIOProfinetIpConfig;
|
|
3929
3978
|
}
|
|
3930
3979
|
/**
|
|
3931
3980
|
*
|
|
@@ -3934,7 +3983,7 @@ export interface ProfinetDescription {
|
|
|
3934
3983
|
*/
|
|
3935
3984
|
export interface ProfinetIO {
|
|
3936
3985
|
/**
|
|
3937
|
-
* The name of the input/output
|
|
3986
|
+
* The name of the input/output variable. This is a human-readable identifier for the value. It distinguishes between different inputs/outputs variables in the system. The variables may be used to set bits or bytes at their pointed to address via [setBusIOValues](setBusIOValues).
|
|
3938
3987
|
* @type {string}
|
|
3939
3988
|
* @memberof ProfinetIO
|
|
3940
3989
|
*/
|
|
@@ -3946,25 +3995,25 @@ export interface ProfinetIO {
|
|
|
3946
3995
|
*/
|
|
3947
3996
|
'type': ProfinetIOTypeEnum;
|
|
3948
3997
|
/**
|
|
3949
|
-
* The direction of the input/output
|
|
3998
|
+
* The direction of the input/output variable, indicating whether it is an input or output for the PROFINET device, e.g. NOVA\'s PROFINET service.
|
|
3950
3999
|
* @type {ProfinetIODirection}
|
|
3951
4000
|
* @memberof ProfinetIO
|
|
3952
4001
|
*/
|
|
3953
4002
|
'direction': ProfinetIODirection;
|
|
3954
4003
|
/**
|
|
3955
|
-
* The byte address of the input/output
|
|
4004
|
+
* The byte address of the input/output variable in the PROFINET device, e.g. NOVA\'s PROFINET service. The byte address is used to locate the specific input/output variable within the device\'s memory or data structure.
|
|
3956
4005
|
* @type {number}
|
|
3957
4006
|
* @memberof ProfinetIO
|
|
3958
4007
|
*/
|
|
3959
4008
|
'byte_address': number;
|
|
3960
4009
|
/**
|
|
3961
|
-
* The bit address of the input/output
|
|
4010
|
+
* The bit address of the input/output variable within the byte or word address. The bit address is used to specify the exact bit within the byte or word that corresponds to the input/output variable.
|
|
3962
4011
|
* @type {number}
|
|
3963
4012
|
* @memberof ProfinetIO
|
|
3964
4013
|
*/
|
|
3965
4014
|
'bit_address'?: number;
|
|
3966
4015
|
/**
|
|
3967
|
-
* The unique identifier for the input/output value. This identifier is used to reference the specific input/output in the NOVA
|
|
4016
|
+
* The unique identifier for the input/output value. This identifier is used to reference the specific input/output variable in the PROFINET device, e.g. NOVA\'s PROFINET service.
|
|
3968
4017
|
* @type {string}
|
|
3969
4018
|
* @memberof ProfinetIO
|
|
3970
4019
|
*/
|
|
@@ -3977,7 +4026,7 @@ export interface ProfinetIO {
|
|
|
3977
4026
|
*/
|
|
3978
4027
|
export interface ProfinetIOData {
|
|
3979
4028
|
/**
|
|
3980
|
-
* The name of the input/output
|
|
4029
|
+
* The name of the input/output variable. This is a human-readable identifier for the value. It distinguishes between different inputs/outputs variables in the system. The variables may be used to set bits or bytes at their pointed to address via [setBusIOValues](setBusIOValues).
|
|
3981
4030
|
* @type {string}
|
|
3982
4031
|
* @memberof ProfinetIOData
|
|
3983
4032
|
*/
|
|
@@ -3989,26 +4038,26 @@ export interface ProfinetIOData {
|
|
|
3989
4038
|
*/
|
|
3990
4039
|
'type': ProfinetIOTypeEnum;
|
|
3991
4040
|
/**
|
|
3992
|
-
* The direction of the input/output
|
|
4041
|
+
* The direction of the input/output variable, indicating whether it is an input or output for the PROFINET device, e.g. NOVA\'s PROFINET service.
|
|
3993
4042
|
* @type {ProfinetIODirection}
|
|
3994
4043
|
* @memberof ProfinetIOData
|
|
3995
4044
|
*/
|
|
3996
4045
|
'direction': ProfinetIODirection;
|
|
3997
4046
|
/**
|
|
3998
|
-
* The byte address of the input/output
|
|
4047
|
+
* The byte address of the input/output variable in the PROFINET device, e.g. NOVA\'s PROFINET service. The byte address is used to locate the specific input/output variable within the device\'s memory or data structure.
|
|
3999
4048
|
* @type {number}
|
|
4000
4049
|
* @memberof ProfinetIOData
|
|
4001
4050
|
*/
|
|
4002
4051
|
'byte_address': number;
|
|
4003
4052
|
/**
|
|
4004
|
-
* The bit address of the input/output
|
|
4053
|
+
* The bit address of the input/output variable within the byte or word address. The bit address is used to specify the exact bit within the byte or word that corresponds to the input/output variable.
|
|
4005
4054
|
* @type {number}
|
|
4006
4055
|
* @memberof ProfinetIOData
|
|
4007
4056
|
*/
|
|
4008
4057
|
'bit_address'?: number;
|
|
4009
4058
|
}
|
|
4010
4059
|
/**
|
|
4011
|
-
*
|
|
4060
|
+
* The direction of the input/output variable, indicating whether it is an input or output for the PROFINET device, e.g. NOVA\'s PROFINET service.
|
|
4012
4061
|
* @export
|
|
4013
4062
|
* @enum {string}
|
|
4014
4063
|
*/
|
|
@@ -4019,7 +4068,7 @@ export declare const ProfinetIODirection: {
|
|
|
4019
4068
|
};
|
|
4020
4069
|
export type ProfinetIODirection = typeof ProfinetIODirection[keyof typeof ProfinetIODirection];
|
|
4021
4070
|
/**
|
|
4022
|
-
* Value type of the PROFINET input/output.
|
|
4071
|
+
* Value type of the PROFINET input/output variable. Is used to interpret the corresponding bits correctly.
|
|
4023
4072
|
* @export
|
|
4024
4073
|
* @enum {string}
|
|
4025
4074
|
*/
|
|
@@ -4043,38 +4092,38 @@ export type ProfinetIOTypeEnum = typeof ProfinetIOTypeEnum[keyof typeof Profinet
|
|
|
4043
4092
|
*/
|
|
4044
4093
|
export interface ProfinetInputOutputConfig {
|
|
4045
4094
|
/**
|
|
4046
|
-
* Content of the input
|
|
4095
|
+
* Content of the input/output variable configuration XML file. The XML File has to be embedded as a string by escaping quotes, line breaks and so forth.
|
|
4047
4096
|
* @type {string}
|
|
4048
4097
|
* @memberof ProfinetInputOutputConfig
|
|
4049
4098
|
*/
|
|
4050
4099
|
'config': string;
|
|
4051
4100
|
/**
|
|
4052
|
-
* Offset in bytes for the input
|
|
4101
|
+
* Offset in bytes for the address of the input (perspective of the controller) variables. The offset will be subtracted from to the byte addresses of the sent XML content.
|
|
4053
4102
|
* @type {number}
|
|
4054
4103
|
* @memberof ProfinetInputOutputConfig
|
|
4055
4104
|
*/
|
|
4056
4105
|
'input_offset': number;
|
|
4057
4106
|
/**
|
|
4058
|
-
* Offset in bytes for the output
|
|
4107
|
+
* Offset in bytes for the address of the output (perspective of the controller) variables. The offset will be subtracted from to the byte addresses of the sent XML content.
|
|
4059
4108
|
* @type {number}
|
|
4060
4109
|
* @memberof ProfinetInputOutputConfig
|
|
4061
4110
|
*/
|
|
4062
4111
|
'output_offset': number;
|
|
4063
4112
|
}
|
|
4064
4113
|
/**
|
|
4065
|
-
*
|
|
4114
|
+
* An array of PROFINET slots. PROFINET models each device’s input/output hardware as a hierarchy of slots (modules) and subslots (submodules). A slot can represent a physical or virtual input/output card and each subslot one of its individual channels or functions. Every slot and subslot has unique identifiers that the controller uses to map cyclic input/output data and parameter records to its process image. This slot/subslot separation enables e.g. addressing each input/output stream when establishing input/output application relations (I/O-AR).
|
|
4066
4115
|
* @export
|
|
4067
4116
|
* @interface ProfinetSlotDescription
|
|
4068
4117
|
*/
|
|
4069
4118
|
export interface ProfinetSlotDescription {
|
|
4070
4119
|
/**
|
|
4071
|
-
* The number of the PROFINET slot.
|
|
4120
|
+
* The number/index of the PROFINET slot. Per default, slot 0 is reserved for the device access point (DAP). Slots that are part of the cyclic input/output data exchange start at number 1.
|
|
4072
4121
|
* @type {number}
|
|
4073
4122
|
* @memberof ProfinetSlotDescription
|
|
4074
4123
|
*/
|
|
4075
4124
|
'number': number;
|
|
4076
4125
|
/**
|
|
4077
|
-
* The API number of the PROFINET input
|
|
4126
|
+
* The application process identifier (API) number of the PROFINET input. The API identifies the application relation (AR) that is using the slot.
|
|
4078
4127
|
* @type {number}
|
|
4079
4128
|
* @memberof ProfinetSlotDescription
|
|
4080
4129
|
*/
|
|
@@ -4093,19 +4142,19 @@ export interface ProfinetSlotDescription {
|
|
|
4093
4142
|
*/
|
|
4094
4143
|
export interface ProfinetSubSlotDescription {
|
|
4095
4144
|
/**
|
|
4096
|
-
* The
|
|
4145
|
+
* The number/index of the PROFINET subslot.
|
|
4097
4146
|
* @type {number}
|
|
4098
4147
|
* @memberof ProfinetSubSlotDescription
|
|
4099
4148
|
*/
|
|
4100
4149
|
'number': number;
|
|
4101
4150
|
/**
|
|
4102
|
-
* The
|
|
4151
|
+
* The amount of bytes allocated for the subslot in the input process image buffer.
|
|
4103
4152
|
* @type {number}
|
|
4104
4153
|
* @memberof ProfinetSubSlotDescription
|
|
4105
4154
|
*/
|
|
4106
4155
|
'input_length': number;
|
|
4107
4156
|
/**
|
|
4108
|
-
* The
|
|
4157
|
+
* The amount of bytes allocated for the subslot in the output process image buffer.
|
|
4109
4158
|
* @type {number}
|
|
4110
4159
|
* @memberof ProfinetSubSlotDescription
|
|
4111
4160
|
*/
|
|
@@ -5562,7 +5611,7 @@ export declare class ApplicationApi extends BaseAPI {
|
|
|
5562
5611
|
*/
|
|
5563
5612
|
export declare const BUSInputsOutputsApiAxiosParamCreator: (configuration?: Configuration) => {
|
|
5564
5613
|
/**
|
|
5565
|
-
* Add
|
|
5614
|
+
* Add the BUS inputs/outputs service to the cell. Starts a containerized service that enables BUS connections via the specified ethernet port.
|
|
5566
5615
|
* @summary Add Service
|
|
5567
5616
|
* @param {string} cell Unique identifier addressing a cell in all API calls.
|
|
5568
5617
|
* @param {BusIOType} busIOType
|
|
@@ -5572,7 +5621,7 @@ export declare const BUSInputsOutputsApiAxiosParamCreator: (configuration?: Conf
|
|
|
5572
5621
|
*/
|
|
5573
5622
|
addBusIOService: (cell: string, busIOType: BusIOType, completionTimeout?: number, options?: RawAxiosRequestConfig) => Promise<RequestArgs>;
|
|
5574
5623
|
/**
|
|
5575
|
-
* Adds an input/output to or updates an input/output on the PROFINET device.
|
|
5624
|
+
* Adds an input/output variable to or updates an input/output variable on the PROFINET device, e.g. NOVA\'s PROFINET service. The inputs/outputs map variables to specific memory addresses in the process image. The default process image has buffer lengths of 64 bytes for input and output. The size of the buffer is determined by the `config_file_content` that is passed in [addBusIOService](addBusIOService) and has to be in accordance with the GSDML file describing the PROFINET device. The PROFINET controller as well as NOVA\'s PROFINET service use an input/output variable configuration to interpret the bits of the input/output process image. The NOVA\'s PROFINET service\'s configuration can be viewed via [listProfinetIOs](listProfinetIOs). For the PROFINET controller, e.g. a connected PLC, refer to the corresponding third party software, e.g. TIA portal).
|
|
5576
5625
|
* @summary Add PROFINET Input/Output
|
|
5577
5626
|
* @param {string} cell Unique identifier addressing a cell in all API calls.
|
|
5578
5627
|
* @param {string} io Unique identifier to address an Input/Output in the cell.
|
|
@@ -5582,7 +5631,7 @@ export declare const BUSInputsOutputsApiAxiosParamCreator: (configuration?: Conf
|
|
|
5582
5631
|
*/
|
|
5583
5632
|
addProfinetIO: (cell: string, io: string, profinetIOData: ProfinetIOData, options?: RawAxiosRequestConfig) => Promise<RequestArgs>;
|
|
5584
5633
|
/**
|
|
5585
|
-
*
|
|
5634
|
+
* Remove the BUS inputs/outputs service from the cell.
|
|
5586
5635
|
* @summary Clear Service
|
|
5587
5636
|
* @param {string} cell Unique identifier addressing a cell in all API calls.
|
|
5588
5637
|
* @param {number} [completionTimeout]
|
|
@@ -5591,7 +5640,7 @@ export declare const BUSInputsOutputsApiAxiosParamCreator: (configuration?: Conf
|
|
|
5591
5640
|
*/
|
|
5592
5641
|
clearBusIOService: (cell: string, completionTimeout?: number, options?: RawAxiosRequestConfig) => Promise<RequestArgs>;
|
|
5593
5642
|
/**
|
|
5594
|
-
* Removes
|
|
5643
|
+
* Removes an input/output variable configuration from the PROFINET device, e.g. NOVA\'s PROFINET service.
|
|
5595
5644
|
* @summary Remove PROFINET Input/Ouptut
|
|
5596
5645
|
* @param {string} cell Unique identifier addressing a cell in all API calls.
|
|
5597
5646
|
* @param {string} io Unique identifier to address an Input/Output in the cell.
|
|
@@ -5600,7 +5649,7 @@ export declare const BUSInputsOutputsApiAxiosParamCreator: (configuration?: Conf
|
|
|
5600
5649
|
*/
|
|
5601
5650
|
deleteProfinetIO: (cell: string, io: string, options?: RawAxiosRequestConfig) => Promise<RequestArgs>;
|
|
5602
5651
|
/**
|
|
5603
|
-
* Get deployed BUS
|
|
5652
|
+
* Get deployed BUS inputs/outputs service.
|
|
5604
5653
|
* @summary Get Service
|
|
5605
5654
|
* @param {string} cell Unique identifier addressing a cell in all API calls.
|
|
5606
5655
|
* @param {*} [options] Override http request option.
|
|
@@ -5625,7 +5674,7 @@ export declare const BUSInputsOutputsApiAxiosParamCreator: (configuration?: Conf
|
|
|
5625
5674
|
*/
|
|
5626
5675
|
getBusIOValues: (cell: string, ios?: Array<string>, options?: RawAxiosRequestConfig) => Promise<RequestArgs>;
|
|
5627
5676
|
/**
|
|
5628
|
-
* Get description of PROFINET
|
|
5677
|
+
* Get description of NOVA as a PROFINET device.
|
|
5629
5678
|
* @summary Get PROFINET Description
|
|
5630
5679
|
* @param {string} cell Unique identifier addressing a cell in all API calls.
|
|
5631
5680
|
* @param {*} [options] Override http request option.
|
|
@@ -5633,7 +5682,7 @@ export declare const BUSInputsOutputsApiAxiosParamCreator: (configuration?: Conf
|
|
|
5633
5682
|
*/
|
|
5634
5683
|
getProfinetDescription: (cell: string, options?: RawAxiosRequestConfig) => Promise<RequestArgs>;
|
|
5635
5684
|
/**
|
|
5636
|
-
* Get input/output configuration of the PROFINET device as file.
|
|
5685
|
+
* Get input/output variable configuration of the PROFINET device, e.g. NOVA\'s PROFINET service as file. You can specify byte offsets for the input and output variable addresses to get an XML tagmap that is ready to paste to the third party software, e.g. TIA portal.
|
|
5637
5686
|
* @summary PROFINET Inputs/Outputs to File
|
|
5638
5687
|
* @param {string} cell Unique identifier addressing a cell in all API calls.
|
|
5639
5688
|
* @param {number} [inputOffset]
|
|
@@ -5643,7 +5692,7 @@ export declare const BUSInputsOutputsApiAxiosParamCreator: (configuration?: Conf
|
|
|
5643
5692
|
*/
|
|
5644
5693
|
getProfinetIOsFromFile: (cell: string, inputOffset?: number, outputOffset?: number, options?: RawAxiosRequestConfig) => Promise<RequestArgs>;
|
|
5645
5694
|
/**
|
|
5646
|
-
* List all BUS
|
|
5695
|
+
* List all input/output descriptions for configured BUS services. The input/output descriptions contain information such as the name, the type and the unit. The I/O direction is given in perspective of the BUS service.
|
|
5647
5696
|
* @summary List Descriptions
|
|
5648
5697
|
* @param {string} cell Unique identifier addressing a cell in all API calls.
|
|
5649
5698
|
* @param {*} [options] Override http request option.
|
|
@@ -5651,7 +5700,7 @@ export declare const BUSInputsOutputsApiAxiosParamCreator: (configuration?: Conf
|
|
|
5651
5700
|
*/
|
|
5652
5701
|
listBusIODescriptions: (cell: string, options?: RawAxiosRequestConfig) => Promise<RequestArgs>;
|
|
5653
5702
|
/**
|
|
5654
|
-
* List all PROFINET input and
|
|
5703
|
+
* List descriptions for all configured input/output variables of the PROFINET service. The input/output descriptions contain information such as the name, the type and the unit. The I/O direction is given in perspective of the PROFINET Device, e.g. the configured PROFINET service. The byte and bit addresses are the locations in the PROFINET input/output process image the variable points to. The PROFINET controller as well as NOVA\'s PROFINET service use an I/O variable configuration to interpret the bits of the input and output process image. The NOVA PROFINET service\'s configuration is modified via [addProfinetIO](addProfinetIO) and [setProfinetIOsFromFile](setProfinetIOsFromFile). For the PROFINET controller, e.g. a connected PLC, refer to the corresponding third party software, e.g. TIA portal.
|
|
5655
5704
|
* @summary List PROFINET Input/Output Configuration
|
|
5656
5705
|
* @param {string} cell Unique identifier addressing a cell in all API calls.
|
|
5657
5706
|
* @param {*} [options] Override http request option.
|
|
@@ -5668,7 +5717,7 @@ export declare const BUSInputsOutputsApiAxiosParamCreator: (configuration?: Conf
|
|
|
5668
5717
|
*/
|
|
5669
5718
|
setBusIOValues: (cell: string, iOValue: Array<IOValue>, options?: RawAxiosRequestConfig) => Promise<RequestArgs>;
|
|
5670
5719
|
/**
|
|
5671
|
-
* Sets
|
|
5720
|
+
* Sets Input/Output variable configuration on the PROFINET device (i.e. NOVA\'s PROFINET service) from XML file. The Inputs/Outputs map variables to specific memory addresses in the process image. The default process image has buffer lengths of 64 bytes for input and output. The size of the buffer is determined by the `config_file_content` that is passed in [addBusIOService](addBusIOService) and has to be in accordance with the GSDML file describing the PROFINET device. The PROFINET controller as well as NOVA\'s PROFINET service use an input/output variable configuration to interpret the bits of the input/output process image. The NOVA\'s PROFINET service\'s configuration can be viewed via [listProfinetIOs](listProfinetIOs). For the PROFINET controller (i.e. a connected PLC), refer to the corresponding engineering system (i.e. TIA portal). You can export the variable configuration of the PROFINET controller as XML file from you engineering system, i.e. TIA portal. The endpoint is built so that the perspective of input and output (PROFINET Device\'s input is PROFINET Controller\'s output) is internally handled, meaning that you can paste the exported XML file here without modifying.
|
|
5672
5721
|
* @summary Set PROFINET Inputs/Outputs from File
|
|
5673
5722
|
* @param {string} cell Unique identifier addressing a cell in all API calls.
|
|
5674
5723
|
* @param {ProfinetInputOutputConfig} profinetInputOutputConfig
|
|
@@ -5683,7 +5732,7 @@ export declare const BUSInputsOutputsApiAxiosParamCreator: (configuration?: Conf
|
|
|
5683
5732
|
*/
|
|
5684
5733
|
export declare const BUSInputsOutputsApiFp: (configuration?: Configuration) => {
|
|
5685
5734
|
/**
|
|
5686
|
-
* Add
|
|
5735
|
+
* Add the BUS inputs/outputs service to the cell. Starts a containerized service that enables BUS connections via the specified ethernet port.
|
|
5687
5736
|
* @summary Add Service
|
|
5688
5737
|
* @param {string} cell Unique identifier addressing a cell in all API calls.
|
|
5689
5738
|
* @param {BusIOType} busIOType
|
|
@@ -5693,7 +5742,7 @@ export declare const BUSInputsOutputsApiFp: (configuration?: Configuration) => {
|
|
|
5693
5742
|
*/
|
|
5694
5743
|
addBusIOService(cell: string, busIOType: BusIOType, completionTimeout?: number, options?: RawAxiosRequestConfig): Promise<(axios?: AxiosInstance, basePath?: string) => AxiosPromise<void>>;
|
|
5695
5744
|
/**
|
|
5696
|
-
* Adds an input/output to or updates an input/output on the PROFINET device.
|
|
5745
|
+
* Adds an input/output variable to or updates an input/output variable on the PROFINET device, e.g. NOVA\'s PROFINET service. The inputs/outputs map variables to specific memory addresses in the process image. The default process image has buffer lengths of 64 bytes for input and output. The size of the buffer is determined by the `config_file_content` that is passed in [addBusIOService](addBusIOService) and has to be in accordance with the GSDML file describing the PROFINET device. The PROFINET controller as well as NOVA\'s PROFINET service use an input/output variable configuration to interpret the bits of the input/output process image. The NOVA\'s PROFINET service\'s configuration can be viewed via [listProfinetIOs](listProfinetIOs). For the PROFINET controller, e.g. a connected PLC, refer to the corresponding third party software, e.g. TIA portal).
|
|
5697
5746
|
* @summary Add PROFINET Input/Output
|
|
5698
5747
|
* @param {string} cell Unique identifier addressing a cell in all API calls.
|
|
5699
5748
|
* @param {string} io Unique identifier to address an Input/Output in the cell.
|
|
@@ -5703,7 +5752,7 @@ export declare const BUSInputsOutputsApiFp: (configuration?: Configuration) => {
|
|
|
5703
5752
|
*/
|
|
5704
5753
|
addProfinetIO(cell: string, io: string, profinetIOData: ProfinetIOData, options?: RawAxiosRequestConfig): Promise<(axios?: AxiosInstance, basePath?: string) => AxiosPromise<void>>;
|
|
5705
5754
|
/**
|
|
5706
|
-
*
|
|
5755
|
+
* Remove the BUS inputs/outputs service from the cell.
|
|
5707
5756
|
* @summary Clear Service
|
|
5708
5757
|
* @param {string} cell Unique identifier addressing a cell in all API calls.
|
|
5709
5758
|
* @param {number} [completionTimeout]
|
|
@@ -5712,7 +5761,7 @@ export declare const BUSInputsOutputsApiFp: (configuration?: Configuration) => {
|
|
|
5712
5761
|
*/
|
|
5713
5762
|
clearBusIOService(cell: string, completionTimeout?: number, options?: RawAxiosRequestConfig): Promise<(axios?: AxiosInstance, basePath?: string) => AxiosPromise<void>>;
|
|
5714
5763
|
/**
|
|
5715
|
-
* Removes
|
|
5764
|
+
* Removes an input/output variable configuration from the PROFINET device, e.g. NOVA\'s PROFINET service.
|
|
5716
5765
|
* @summary Remove PROFINET Input/Ouptut
|
|
5717
5766
|
* @param {string} cell Unique identifier addressing a cell in all API calls.
|
|
5718
5767
|
* @param {string} io Unique identifier to address an Input/Output in the cell.
|
|
@@ -5721,7 +5770,7 @@ export declare const BUSInputsOutputsApiFp: (configuration?: Configuration) => {
|
|
|
5721
5770
|
*/
|
|
5722
5771
|
deleteProfinetIO(cell: string, io: string, options?: RawAxiosRequestConfig): Promise<(axios?: AxiosInstance, basePath?: string) => AxiosPromise<void>>;
|
|
5723
5772
|
/**
|
|
5724
|
-
* Get deployed BUS
|
|
5773
|
+
* Get deployed BUS inputs/outputs service.
|
|
5725
5774
|
* @summary Get Service
|
|
5726
5775
|
* @param {string} cell Unique identifier addressing a cell in all API calls.
|
|
5727
5776
|
* @param {*} [options] Override http request option.
|
|
@@ -5746,7 +5795,7 @@ export declare const BUSInputsOutputsApiFp: (configuration?: Configuration) => {
|
|
|
5746
5795
|
*/
|
|
5747
5796
|
getBusIOValues(cell: string, ios?: Array<string>, options?: RawAxiosRequestConfig): Promise<(axios?: AxiosInstance, basePath?: string) => AxiosPromise<Array<IOValue>>>;
|
|
5748
5797
|
/**
|
|
5749
|
-
* Get description of PROFINET
|
|
5798
|
+
* Get description of NOVA as a PROFINET device.
|
|
5750
5799
|
* @summary Get PROFINET Description
|
|
5751
5800
|
* @param {string} cell Unique identifier addressing a cell in all API calls.
|
|
5752
5801
|
* @param {*} [options] Override http request option.
|
|
@@ -5754,7 +5803,7 @@ export declare const BUSInputsOutputsApiFp: (configuration?: Configuration) => {
|
|
|
5754
5803
|
*/
|
|
5755
5804
|
getProfinetDescription(cell: string, options?: RawAxiosRequestConfig): Promise<(axios?: AxiosInstance, basePath?: string) => AxiosPromise<ProfinetDescription>>;
|
|
5756
5805
|
/**
|
|
5757
|
-
* Get input/output configuration of the PROFINET device as file.
|
|
5806
|
+
* Get input/output variable configuration of the PROFINET device, e.g. NOVA\'s PROFINET service as file. You can specify byte offsets for the input and output variable addresses to get an XML tagmap that is ready to paste to the third party software, e.g. TIA portal.
|
|
5758
5807
|
* @summary PROFINET Inputs/Outputs to File
|
|
5759
5808
|
* @param {string} cell Unique identifier addressing a cell in all API calls.
|
|
5760
5809
|
* @param {number} [inputOffset]
|
|
@@ -5764,15 +5813,15 @@ export declare const BUSInputsOutputsApiFp: (configuration?: Configuration) => {
|
|
|
5764
5813
|
*/
|
|
5765
5814
|
getProfinetIOsFromFile(cell: string, inputOffset?: number, outputOffset?: number, options?: RawAxiosRequestConfig): Promise<(axios?: AxiosInstance, basePath?: string) => AxiosPromise<string>>;
|
|
5766
5815
|
/**
|
|
5767
|
-
* List all BUS
|
|
5816
|
+
* List all input/output descriptions for configured BUS services. The input/output descriptions contain information such as the name, the type and the unit. The I/O direction is given in perspective of the BUS service.
|
|
5768
5817
|
* @summary List Descriptions
|
|
5769
5818
|
* @param {string} cell Unique identifier addressing a cell in all API calls.
|
|
5770
5819
|
* @param {*} [options] Override http request option.
|
|
5771
5820
|
* @throws {RequiredError}
|
|
5772
5821
|
*/
|
|
5773
|
-
listBusIODescriptions(cell: string, options?: RawAxiosRequestConfig): Promise<(axios?: AxiosInstance, basePath?: string) => AxiosPromise<Array<
|
|
5822
|
+
listBusIODescriptions(cell: string, options?: RawAxiosRequestConfig): Promise<(axios?: AxiosInstance, basePath?: string) => AxiosPromise<Array<IODescription2>>>;
|
|
5774
5823
|
/**
|
|
5775
|
-
* List all PROFINET input and
|
|
5824
|
+
* List descriptions for all configured input/output variables of the PROFINET service. The input/output descriptions contain information such as the name, the type and the unit. The I/O direction is given in perspective of the PROFINET Device, e.g. the configured PROFINET service. The byte and bit addresses are the locations in the PROFINET input/output process image the variable points to. The PROFINET controller as well as NOVA\'s PROFINET service use an I/O variable configuration to interpret the bits of the input and output process image. The NOVA PROFINET service\'s configuration is modified via [addProfinetIO](addProfinetIO) and [setProfinetIOsFromFile](setProfinetIOsFromFile). For the PROFINET controller, e.g. a connected PLC, refer to the corresponding third party software, e.g. TIA portal.
|
|
5776
5825
|
* @summary List PROFINET Input/Output Configuration
|
|
5777
5826
|
* @param {string} cell Unique identifier addressing a cell in all API calls.
|
|
5778
5827
|
* @param {*} [options] Override http request option.
|
|
@@ -5789,7 +5838,7 @@ export declare const BUSInputsOutputsApiFp: (configuration?: Configuration) => {
|
|
|
5789
5838
|
*/
|
|
5790
5839
|
setBusIOValues(cell: string, iOValue: Array<IOValue>, options?: RawAxiosRequestConfig): Promise<(axios?: AxiosInstance, basePath?: string) => AxiosPromise<void>>;
|
|
5791
5840
|
/**
|
|
5792
|
-
* Sets
|
|
5841
|
+
* Sets Input/Output variable configuration on the PROFINET device (i.e. NOVA\'s PROFINET service) from XML file. The Inputs/Outputs map variables to specific memory addresses in the process image. The default process image has buffer lengths of 64 bytes for input and output. The size of the buffer is determined by the `config_file_content` that is passed in [addBusIOService](addBusIOService) and has to be in accordance with the GSDML file describing the PROFINET device. The PROFINET controller as well as NOVA\'s PROFINET service use an input/output variable configuration to interpret the bits of the input/output process image. The NOVA\'s PROFINET service\'s configuration can be viewed via [listProfinetIOs](listProfinetIOs). For the PROFINET controller (i.e. a connected PLC), refer to the corresponding engineering system (i.e. TIA portal). You can export the variable configuration of the PROFINET controller as XML file from you engineering system, i.e. TIA portal. The endpoint is built so that the perspective of input and output (PROFINET Device\'s input is PROFINET Controller\'s output) is internally handled, meaning that you can paste the exported XML file here without modifying.
|
|
5793
5842
|
* @summary Set PROFINET Inputs/Outputs from File
|
|
5794
5843
|
* @param {string} cell Unique identifier addressing a cell in all API calls.
|
|
5795
5844
|
* @param {ProfinetInputOutputConfig} profinetInputOutputConfig
|
|
@@ -5804,7 +5853,7 @@ export declare const BUSInputsOutputsApiFp: (configuration?: Configuration) => {
|
|
|
5804
5853
|
*/
|
|
5805
5854
|
export declare const BUSInputsOutputsApiFactory: (configuration?: Configuration, basePath?: string, axios?: AxiosInstance) => {
|
|
5806
5855
|
/**
|
|
5807
|
-
* Add
|
|
5856
|
+
* Add the BUS inputs/outputs service to the cell. Starts a containerized service that enables BUS connections via the specified ethernet port.
|
|
5808
5857
|
* @summary Add Service
|
|
5809
5858
|
* @param {string} cell Unique identifier addressing a cell in all API calls.
|
|
5810
5859
|
* @param {BusIOType} busIOType
|
|
@@ -5814,7 +5863,7 @@ export declare const BUSInputsOutputsApiFactory: (configuration?: Configuration,
|
|
|
5814
5863
|
*/
|
|
5815
5864
|
addBusIOService(cell: string, busIOType: BusIOType, completionTimeout?: number, options?: RawAxiosRequestConfig): AxiosPromise<void>;
|
|
5816
5865
|
/**
|
|
5817
|
-
* Adds an input/output to or updates an input/output on the PROFINET device.
|
|
5866
|
+
* Adds an input/output variable to or updates an input/output variable on the PROFINET device, e.g. NOVA\'s PROFINET service. The inputs/outputs map variables to specific memory addresses in the process image. The default process image has buffer lengths of 64 bytes for input and output. The size of the buffer is determined by the `config_file_content` that is passed in [addBusIOService](addBusIOService) and has to be in accordance with the GSDML file describing the PROFINET device. The PROFINET controller as well as NOVA\'s PROFINET service use an input/output variable configuration to interpret the bits of the input/output process image. The NOVA\'s PROFINET service\'s configuration can be viewed via [listProfinetIOs](listProfinetIOs). For the PROFINET controller, e.g. a connected PLC, refer to the corresponding third party software, e.g. TIA portal).
|
|
5818
5867
|
* @summary Add PROFINET Input/Output
|
|
5819
5868
|
* @param {string} cell Unique identifier addressing a cell in all API calls.
|
|
5820
5869
|
* @param {string} io Unique identifier to address an Input/Output in the cell.
|
|
@@ -5824,7 +5873,7 @@ export declare const BUSInputsOutputsApiFactory: (configuration?: Configuration,
|
|
|
5824
5873
|
*/
|
|
5825
5874
|
addProfinetIO(cell: string, io: string, profinetIOData: ProfinetIOData, options?: RawAxiosRequestConfig): AxiosPromise<void>;
|
|
5826
5875
|
/**
|
|
5827
|
-
*
|
|
5876
|
+
* Remove the BUS inputs/outputs service from the cell.
|
|
5828
5877
|
* @summary Clear Service
|
|
5829
5878
|
* @param {string} cell Unique identifier addressing a cell in all API calls.
|
|
5830
5879
|
* @param {number} [completionTimeout]
|
|
@@ -5833,7 +5882,7 @@ export declare const BUSInputsOutputsApiFactory: (configuration?: Configuration,
|
|
|
5833
5882
|
*/
|
|
5834
5883
|
clearBusIOService(cell: string, completionTimeout?: number, options?: RawAxiosRequestConfig): AxiosPromise<void>;
|
|
5835
5884
|
/**
|
|
5836
|
-
* Removes
|
|
5885
|
+
* Removes an input/output variable configuration from the PROFINET device, e.g. NOVA\'s PROFINET service.
|
|
5837
5886
|
* @summary Remove PROFINET Input/Ouptut
|
|
5838
5887
|
* @param {string} cell Unique identifier addressing a cell in all API calls.
|
|
5839
5888
|
* @param {string} io Unique identifier to address an Input/Output in the cell.
|
|
@@ -5842,7 +5891,7 @@ export declare const BUSInputsOutputsApiFactory: (configuration?: Configuration,
|
|
|
5842
5891
|
*/
|
|
5843
5892
|
deleteProfinetIO(cell: string, io: string, options?: RawAxiosRequestConfig): AxiosPromise<void>;
|
|
5844
5893
|
/**
|
|
5845
|
-
* Get deployed BUS
|
|
5894
|
+
* Get deployed BUS inputs/outputs service.
|
|
5846
5895
|
* @summary Get Service
|
|
5847
5896
|
* @param {string} cell Unique identifier addressing a cell in all API calls.
|
|
5848
5897
|
* @param {*} [options] Override http request option.
|
|
@@ -5867,7 +5916,7 @@ export declare const BUSInputsOutputsApiFactory: (configuration?: Configuration,
|
|
|
5867
5916
|
*/
|
|
5868
5917
|
getBusIOValues(cell: string, ios?: Array<string>, options?: RawAxiosRequestConfig): AxiosPromise<Array<IOValue>>;
|
|
5869
5918
|
/**
|
|
5870
|
-
* Get description of PROFINET
|
|
5919
|
+
* Get description of NOVA as a PROFINET device.
|
|
5871
5920
|
* @summary Get PROFINET Description
|
|
5872
5921
|
* @param {string} cell Unique identifier addressing a cell in all API calls.
|
|
5873
5922
|
* @param {*} [options] Override http request option.
|
|
@@ -5875,7 +5924,7 @@ export declare const BUSInputsOutputsApiFactory: (configuration?: Configuration,
|
|
|
5875
5924
|
*/
|
|
5876
5925
|
getProfinetDescription(cell: string, options?: RawAxiosRequestConfig): AxiosPromise<ProfinetDescription>;
|
|
5877
5926
|
/**
|
|
5878
|
-
* Get input/output configuration of the PROFINET device as file.
|
|
5927
|
+
* Get input/output variable configuration of the PROFINET device, e.g. NOVA\'s PROFINET service as file. You can specify byte offsets for the input and output variable addresses to get an XML tagmap that is ready to paste to the third party software, e.g. TIA portal.
|
|
5879
5928
|
* @summary PROFINET Inputs/Outputs to File
|
|
5880
5929
|
* @param {string} cell Unique identifier addressing a cell in all API calls.
|
|
5881
5930
|
* @param {number} [inputOffset]
|
|
@@ -5885,15 +5934,15 @@ export declare const BUSInputsOutputsApiFactory: (configuration?: Configuration,
|
|
|
5885
5934
|
*/
|
|
5886
5935
|
getProfinetIOsFromFile(cell: string, inputOffset?: number, outputOffset?: number, options?: RawAxiosRequestConfig): AxiosPromise<string>;
|
|
5887
5936
|
/**
|
|
5888
|
-
* List all BUS
|
|
5937
|
+
* List all input/output descriptions for configured BUS services. The input/output descriptions contain information such as the name, the type and the unit. The I/O direction is given in perspective of the BUS service.
|
|
5889
5938
|
* @summary List Descriptions
|
|
5890
5939
|
* @param {string} cell Unique identifier addressing a cell in all API calls.
|
|
5891
5940
|
* @param {*} [options] Override http request option.
|
|
5892
5941
|
* @throws {RequiredError}
|
|
5893
5942
|
*/
|
|
5894
|
-
listBusIODescriptions(cell: string, options?: RawAxiosRequestConfig): AxiosPromise<Array<
|
|
5943
|
+
listBusIODescriptions(cell: string, options?: RawAxiosRequestConfig): AxiosPromise<Array<IODescription2>>;
|
|
5895
5944
|
/**
|
|
5896
|
-
* List all PROFINET input and
|
|
5945
|
+
* List descriptions for all configured input/output variables of the PROFINET service. The input/output descriptions contain information such as the name, the type and the unit. The I/O direction is given in perspective of the PROFINET Device, e.g. the configured PROFINET service. The byte and bit addresses are the locations in the PROFINET input/output process image the variable points to. The PROFINET controller as well as NOVA\'s PROFINET service use an I/O variable configuration to interpret the bits of the input and output process image. The NOVA PROFINET service\'s configuration is modified via [addProfinetIO](addProfinetIO) and [setProfinetIOsFromFile](setProfinetIOsFromFile). For the PROFINET controller, e.g. a connected PLC, refer to the corresponding third party software, e.g. TIA portal.
|
|
5897
5946
|
* @summary List PROFINET Input/Output Configuration
|
|
5898
5947
|
* @param {string} cell Unique identifier addressing a cell in all API calls.
|
|
5899
5948
|
* @param {*} [options] Override http request option.
|
|
@@ -5910,7 +5959,7 @@ export declare const BUSInputsOutputsApiFactory: (configuration?: Configuration,
|
|
|
5910
5959
|
*/
|
|
5911
5960
|
setBusIOValues(cell: string, iOValue: Array<IOValue>, options?: RawAxiosRequestConfig): AxiosPromise<void>;
|
|
5912
5961
|
/**
|
|
5913
|
-
* Sets
|
|
5962
|
+
* Sets Input/Output variable configuration on the PROFINET device (i.e. NOVA\'s PROFINET service) from XML file. The Inputs/Outputs map variables to specific memory addresses in the process image. The default process image has buffer lengths of 64 bytes for input and output. The size of the buffer is determined by the `config_file_content` that is passed in [addBusIOService](addBusIOService) and has to be in accordance with the GSDML file describing the PROFINET device. The PROFINET controller as well as NOVA\'s PROFINET service use an input/output variable configuration to interpret the bits of the input/output process image. The NOVA\'s PROFINET service\'s configuration can be viewed via [listProfinetIOs](listProfinetIOs). For the PROFINET controller (i.e. a connected PLC), refer to the corresponding engineering system (i.e. TIA portal). You can export the variable configuration of the PROFINET controller as XML file from you engineering system, i.e. TIA portal. The endpoint is built so that the perspective of input and output (PROFINET Device\'s input is PROFINET Controller\'s output) is internally handled, meaning that you can paste the exported XML file here without modifying.
|
|
5914
5963
|
* @summary Set PROFINET Inputs/Outputs from File
|
|
5915
5964
|
* @param {string} cell Unique identifier addressing a cell in all API calls.
|
|
5916
5965
|
* @param {ProfinetInputOutputConfig} profinetInputOutputConfig
|
|
@@ -5927,7 +5976,7 @@ export declare const BUSInputsOutputsApiFactory: (configuration?: Configuration,
|
|
|
5927
5976
|
*/
|
|
5928
5977
|
export declare class BUSInputsOutputsApi extends BaseAPI {
|
|
5929
5978
|
/**
|
|
5930
|
-
* Add
|
|
5979
|
+
* Add the BUS inputs/outputs service to the cell. Starts a containerized service that enables BUS connections via the specified ethernet port.
|
|
5931
5980
|
* @summary Add Service
|
|
5932
5981
|
* @param {string} cell Unique identifier addressing a cell in all API calls.
|
|
5933
5982
|
* @param {BusIOType} busIOType
|
|
@@ -5938,7 +5987,7 @@ export declare class BUSInputsOutputsApi extends BaseAPI {
|
|
|
5938
5987
|
*/
|
|
5939
5988
|
addBusIOService(cell: string, busIOType: BusIOType, completionTimeout?: number, options?: RawAxiosRequestConfig): Promise<import("axios").AxiosResponse<void, any>>;
|
|
5940
5989
|
/**
|
|
5941
|
-
* Adds an input/output to or updates an input/output on the PROFINET device.
|
|
5990
|
+
* Adds an input/output variable to or updates an input/output variable on the PROFINET device, e.g. NOVA\'s PROFINET service. The inputs/outputs map variables to specific memory addresses in the process image. The default process image has buffer lengths of 64 bytes for input and output. The size of the buffer is determined by the `config_file_content` that is passed in [addBusIOService](addBusIOService) and has to be in accordance with the GSDML file describing the PROFINET device. The PROFINET controller as well as NOVA\'s PROFINET service use an input/output variable configuration to interpret the bits of the input/output process image. The NOVA\'s PROFINET service\'s configuration can be viewed via [listProfinetIOs](listProfinetIOs). For the PROFINET controller, e.g. a connected PLC, refer to the corresponding third party software, e.g. TIA portal).
|
|
5942
5991
|
* @summary Add PROFINET Input/Output
|
|
5943
5992
|
* @param {string} cell Unique identifier addressing a cell in all API calls.
|
|
5944
5993
|
* @param {string} io Unique identifier to address an Input/Output in the cell.
|
|
@@ -5949,7 +5998,7 @@ export declare class BUSInputsOutputsApi extends BaseAPI {
|
|
|
5949
5998
|
*/
|
|
5950
5999
|
addProfinetIO(cell: string, io: string, profinetIOData: ProfinetIOData, options?: RawAxiosRequestConfig): Promise<import("axios").AxiosResponse<void, any>>;
|
|
5951
6000
|
/**
|
|
5952
|
-
*
|
|
6001
|
+
* Remove the BUS inputs/outputs service from the cell.
|
|
5953
6002
|
* @summary Clear Service
|
|
5954
6003
|
* @param {string} cell Unique identifier addressing a cell in all API calls.
|
|
5955
6004
|
* @param {number} [completionTimeout]
|
|
@@ -5959,7 +6008,7 @@ export declare class BUSInputsOutputsApi extends BaseAPI {
|
|
|
5959
6008
|
*/
|
|
5960
6009
|
clearBusIOService(cell: string, completionTimeout?: number, options?: RawAxiosRequestConfig): Promise<import("axios").AxiosResponse<void, any>>;
|
|
5961
6010
|
/**
|
|
5962
|
-
* Removes
|
|
6011
|
+
* Removes an input/output variable configuration from the PROFINET device, e.g. NOVA\'s PROFINET service.
|
|
5963
6012
|
* @summary Remove PROFINET Input/Ouptut
|
|
5964
6013
|
* @param {string} cell Unique identifier addressing a cell in all API calls.
|
|
5965
6014
|
* @param {string} io Unique identifier to address an Input/Output in the cell.
|
|
@@ -5969,16 +6018,14 @@ export declare class BUSInputsOutputsApi extends BaseAPI {
|
|
|
5969
6018
|
*/
|
|
5970
6019
|
deleteProfinetIO(cell: string, io: string, options?: RawAxiosRequestConfig): Promise<import("axios").AxiosResponse<void, any>>;
|
|
5971
6020
|
/**
|
|
5972
|
-
* Get deployed BUS
|
|
6021
|
+
* Get deployed BUS inputs/outputs service.
|
|
5973
6022
|
* @summary Get Service
|
|
5974
6023
|
* @param {string} cell Unique identifier addressing a cell in all API calls.
|
|
5975
6024
|
* @param {*} [options] Override http request option.
|
|
5976
6025
|
* @throws {RequiredError}
|
|
5977
6026
|
* @memberof BUSInputsOutputsApi
|
|
5978
6027
|
*/
|
|
5979
|
-
getBusIOService(cell: string, options?: RawAxiosRequestConfig): Promise<import("axios").AxiosResponse<
|
|
5980
|
-
bus_type: "profinet";
|
|
5981
|
-
} & BusIOProfinet, any>>;
|
|
6028
|
+
getBusIOService(cell: string, options?: RawAxiosRequestConfig): Promise<import("axios").AxiosResponse<BusIOType, any>>;
|
|
5982
6029
|
/**
|
|
5983
6030
|
* Get the current state of the BUS Inputs/Outputs service.
|
|
5984
6031
|
* @summary State
|
|
@@ -5999,7 +6046,7 @@ export declare class BUSInputsOutputsApi extends BaseAPI {
|
|
|
5999
6046
|
*/
|
|
6000
6047
|
getBusIOValues(cell: string, ios?: Array<string>, options?: RawAxiosRequestConfig): Promise<import("axios").AxiosResponse<IOValue[], any>>;
|
|
6001
6048
|
/**
|
|
6002
|
-
* Get description of PROFINET
|
|
6049
|
+
* Get description of NOVA as a PROFINET device.
|
|
6003
6050
|
* @summary Get PROFINET Description
|
|
6004
6051
|
* @param {string} cell Unique identifier addressing a cell in all API calls.
|
|
6005
6052
|
* @param {*} [options] Override http request option.
|
|
@@ -6008,7 +6055,7 @@ export declare class BUSInputsOutputsApi extends BaseAPI {
|
|
|
6008
6055
|
*/
|
|
6009
6056
|
getProfinetDescription(cell: string, options?: RawAxiosRequestConfig): Promise<import("axios").AxiosResponse<ProfinetDescription, any>>;
|
|
6010
6057
|
/**
|
|
6011
|
-
* Get input/output configuration of the PROFINET device as file.
|
|
6058
|
+
* Get input/output variable configuration of the PROFINET device, e.g. NOVA\'s PROFINET service as file. You can specify byte offsets for the input and output variable addresses to get an XML tagmap that is ready to paste to the third party software, e.g. TIA portal.
|
|
6012
6059
|
* @summary PROFINET Inputs/Outputs to File
|
|
6013
6060
|
* @param {string} cell Unique identifier addressing a cell in all API calls.
|
|
6014
6061
|
* @param {number} [inputOffset]
|
|
@@ -6019,16 +6066,16 @@ export declare class BUSInputsOutputsApi extends BaseAPI {
|
|
|
6019
6066
|
*/
|
|
6020
6067
|
getProfinetIOsFromFile(cell: string, inputOffset?: number, outputOffset?: number, options?: RawAxiosRequestConfig): Promise<import("axios").AxiosResponse<string, any>>;
|
|
6021
6068
|
/**
|
|
6022
|
-
* List all BUS
|
|
6069
|
+
* List all input/output descriptions for configured BUS services. The input/output descriptions contain information such as the name, the type and the unit. The I/O direction is given in perspective of the BUS service.
|
|
6023
6070
|
* @summary List Descriptions
|
|
6024
6071
|
* @param {string} cell Unique identifier addressing a cell in all API calls.
|
|
6025
6072
|
* @param {*} [options] Override http request option.
|
|
6026
6073
|
* @throws {RequiredError}
|
|
6027
6074
|
* @memberof BUSInputsOutputsApi
|
|
6028
6075
|
*/
|
|
6029
|
-
listBusIODescriptions(cell: string, options?: RawAxiosRequestConfig): Promise<import("axios").AxiosResponse<
|
|
6076
|
+
listBusIODescriptions(cell: string, options?: RawAxiosRequestConfig): Promise<import("axios").AxiosResponse<IODescription2[], any>>;
|
|
6030
6077
|
/**
|
|
6031
|
-
* List all PROFINET input and
|
|
6078
|
+
* List descriptions for all configured input/output variables of the PROFINET service. The input/output descriptions contain information such as the name, the type and the unit. The I/O direction is given in perspective of the PROFINET Device, e.g. the configured PROFINET service. The byte and bit addresses are the locations in the PROFINET input/output process image the variable points to. The PROFINET controller as well as NOVA\'s PROFINET service use an I/O variable configuration to interpret the bits of the input and output process image. The NOVA PROFINET service\'s configuration is modified via [addProfinetIO](addProfinetIO) and [setProfinetIOsFromFile](setProfinetIOsFromFile). For the PROFINET controller, e.g. a connected PLC, refer to the corresponding third party software, e.g. TIA portal.
|
|
6032
6079
|
* @summary List PROFINET Input/Output Configuration
|
|
6033
6080
|
* @param {string} cell Unique identifier addressing a cell in all API calls.
|
|
6034
6081
|
* @param {*} [options] Override http request option.
|
|
@@ -6047,7 +6094,7 @@ export declare class BUSInputsOutputsApi extends BaseAPI {
|
|
|
6047
6094
|
*/
|
|
6048
6095
|
setBusIOValues(cell: string, iOValue: Array<IOValue>, options?: RawAxiosRequestConfig): Promise<import("axios").AxiosResponse<void, any>>;
|
|
6049
6096
|
/**
|
|
6050
|
-
* Sets
|
|
6097
|
+
* Sets Input/Output variable configuration on the PROFINET device (i.e. NOVA\'s PROFINET service) from XML file. The Inputs/Outputs map variables to specific memory addresses in the process image. The default process image has buffer lengths of 64 bytes for input and output. The size of the buffer is determined by the `config_file_content` that is passed in [addBusIOService](addBusIOService) and has to be in accordance with the GSDML file describing the PROFINET device. The PROFINET controller as well as NOVA\'s PROFINET service use an input/output variable configuration to interpret the bits of the input/output process image. The NOVA\'s PROFINET service\'s configuration can be viewed via [listProfinetIOs](listProfinetIOs). For the PROFINET controller (i.e. a connected PLC), refer to the corresponding engineering system (i.e. TIA portal). You can export the variable configuration of the PROFINET controller as XML file from you engineering system, i.e. TIA portal. The endpoint is built so that the perspective of input and output (PROFINET Device\'s input is PROFINET Controller\'s output) is internally handled, meaning that you can paste the exported XML file here without modifying.
|
|
6051
6098
|
* @summary Set PROFINET Inputs/Outputs from File
|
|
6052
6099
|
* @param {string} cell Unique identifier addressing a cell in all API calls.
|
|
6053
6100
|
* @param {ProfinetInputOutputConfig} profinetInputOutputConfig
|