@seamapi/types 1.1201.0 → 1.1203.0

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (32) hide show
  1. package/lib/seam/connect/models/acs/acs-system.d.ts +4 -4
  2. package/lib/seam/connect/models/action-attempts/action-attempt.d.ts +9 -9
  3. package/lib/seam/connect/models/action-attempts/action-attempt.js +2 -2
  4. package/lib/seam/connect/models/action-attempts/action-attempt.js.map +1 -1
  5. package/lib/seam/connect/models/action-attempts/{set-pool-heating.d.ts → set-temperature-controller-mode.d.ts} +10 -10
  6. package/lib/seam/connect/models/action-attempts/{set-pool-heating.js → set-temperature-controller-mode.js} +7 -7
  7. package/lib/seam/connect/models/action-attempts/set-temperature-controller-mode.js.map +1 -0
  8. package/lib/seam/connect/models/devices/capability-properties/lock.js +1 -0
  9. package/lib/seam/connect/models/devices/capability-properties/lock.js.map +1 -1
  10. package/lib/seam/connect/models/devices/device-metadata.d.ts +10 -25
  11. package/lib/seam/connect/models/devices/device-metadata.js +7 -19
  12. package/lib/seam/connect/models/devices/device-metadata.js.map +1 -1
  13. package/lib/seam/connect/models/devices/device-type.d.ts +4 -4
  14. package/lib/seam/connect/models/devices/device-type.js +3 -3
  15. package/lib/seam/connect/models/devices/device-type.js.map +1 -1
  16. package/lib/seam/connect/models/devices/device.d.ts +27 -48
  17. package/lib/seam/connect/models/devices/unmanaged-device.d.ts +23 -38
  18. package/lib/seam/connect/models/events/devices.d.ts +4 -4
  19. package/lib/seam/connect/models/events/seam-event.d.ts +2 -2
  20. package/lib/seam/connect/openapi.js +34 -43
  21. package/lib/seam/connect/openapi.js.map +1 -1
  22. package/lib/seam/connect/route-types.d.ts +457 -547
  23. package/package.json +1 -1
  24. package/src/lib/seam/connect/models/action-attempts/action-attempt.ts +2 -2
  25. package/src/lib/seam/connect/models/action-attempts/set-temperature-controller-mode.ts +54 -0
  26. package/src/lib/seam/connect/models/devices/capability-properties/lock.ts +1 -0
  27. package/src/lib/seam/connect/models/devices/device-metadata.ts +7 -23
  28. package/src/lib/seam/connect/models/devices/device-type.ts +3 -3
  29. package/src/lib/seam/connect/openapi.ts +35 -46
  30. package/src/lib/seam/connect/route-types.ts +457 -581
  31. package/lib/seam/connect/models/action-attempts/set-pool-heating.js.map +0 -1
  32. package/src/lib/seam/connect/models/action-attempts/set-pool-heating.ts +0 -53
@@ -1975,16 +1975,16 @@ export type Routes = {
1975
1975
  result: null;
1976
1976
  /** Errors associated with the action attempt. Null for pending action attempts. */
1977
1977
  error: null;
1978
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
1979
- action_type: 'SET_POOL_HEATING';
1978
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
1979
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
1980
1980
  } | {
1981
1981
  /** ID of the action attempt. */
1982
1982
  action_attempt_id: string;
1983
1983
  status: 'success';
1984
1984
  /** Errors associated with the action attempt. Null for successful action attempts. */
1985
1985
  error: null;
1986
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
1987
- action_type: 'SET_POOL_HEATING';
1986
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
1987
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
1988
1988
  /** Result of the action. */
1989
1989
  result: {};
1990
1990
  } | {
@@ -1993,8 +1993,8 @@ export type Routes = {
1993
1993
  status: 'error';
1994
1994
  /** Result of the action attempt. Null for failed action attempts. */
1995
1995
  result: null;
1996
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
1997
- action_type: 'SET_POOL_HEATING';
1996
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
1997
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
1998
1998
  /** Error associated with the action. */
1999
1999
  error: {
2000
2000
  /** Type of the error. */
@@ -5267,16 +5267,16 @@ export type Routes = {
5267
5267
  result: null;
5268
5268
  /** Errors associated with the action attempt. Null for pending action attempts. */
5269
5269
  error: null;
5270
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
5271
- action_type: 'SET_POOL_HEATING';
5270
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
5271
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
5272
5272
  } | {
5273
5273
  /** ID of the action attempt. */
5274
5274
  action_attempt_id: string;
5275
5275
  status: 'success';
5276
5276
  /** Errors associated with the action attempt. Null for successful action attempts. */
5277
5277
  error: null;
5278
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
5279
- action_type: 'SET_POOL_HEATING';
5278
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
5279
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
5280
5280
  /** Result of the action. */
5281
5281
  result: {};
5282
5282
  } | {
@@ -5285,8 +5285,8 @@ export type Routes = {
5285
5285
  status: 'error';
5286
5286
  /** Result of the action attempt. Null for failed action attempts. */
5287
5287
  result: null;
5288
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
5289
- action_type: 'SET_POOL_HEATING';
5288
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
5289
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
5290
5290
  /** Error associated with the action. */
5291
5291
  error: {
5292
5292
  /** Type of the error. */
@@ -10161,16 +10161,16 @@ export type Routes = {
10161
10161
  result: null;
10162
10162
  /** Errors associated with the action attempt. Null for pending action attempts. */
10163
10163
  error: null;
10164
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
10165
- action_type: 'SET_POOL_HEATING';
10164
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
10165
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
10166
10166
  } | {
10167
10167
  /** ID of the action attempt. */
10168
10168
  action_attempt_id: string;
10169
10169
  status: 'success';
10170
10170
  /** Errors associated with the action attempt. Null for successful action attempts. */
10171
10171
  error: null;
10172
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
10173
- action_type: 'SET_POOL_HEATING';
10172
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
10173
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
10174
10174
  /** Result of the action. */
10175
10175
  result: {};
10176
10176
  } | {
@@ -10179,8 +10179,8 @@ export type Routes = {
10179
10179
  status: 'error';
10180
10180
  /** Result of the action attempt. Null for failed action attempts. */
10181
10181
  result: null;
10182
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
10183
- action_type: 'SET_POOL_HEATING';
10182
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
10183
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
10184
10184
  /** Error associated with the action. */
10185
10185
  error: {
10186
10186
  /** Type of the error. */
@@ -13318,16 +13318,16 @@ export type Routes = {
13318
13318
  result: null;
13319
13319
  /** Errors associated with the action attempt. Null for pending action attempts. */
13320
13320
  error: null;
13321
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
13322
- action_type: 'SET_POOL_HEATING';
13321
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
13322
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
13323
13323
  } | {
13324
13324
  /** ID of the action attempt. */
13325
13325
  action_attempt_id: string;
13326
13326
  status: 'success';
13327
13327
  /** Errors associated with the action attempt. Null for successful action attempts. */
13328
13328
  error: null;
13329
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
13330
- action_type: 'SET_POOL_HEATING';
13329
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
13330
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
13331
13331
  /** Result of the action. */
13332
13332
  result: {};
13333
13333
  } | {
@@ -13336,8 +13336,8 @@ export type Routes = {
13336
13336
  status: 'error';
13337
13337
  /** Result of the action attempt. Null for failed action attempts. */
13338
13338
  result: null;
13339
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
13340
- action_type: 'SET_POOL_HEATING';
13339
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
13340
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
13341
13341
  /** Error associated with the action. */
13342
13342
  error: {
13343
13343
  /** Type of the error. */
@@ -14220,7 +14220,7 @@ export type Routes = {
14220
14220
  /** ID of the device. */
14221
14221
  device_id: string;
14222
14222
  /** Type of the device. The `august_lock` and `yale_lock` values are deprecated. Use `yale_access_lock` in place of `august_lock`, and `yale_access_lock` or `yale_home_lock` in place of `yale_lock`. */
14223
- device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_system' | 'hayward_pool');
14223
+ device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_controller' | 'hayward_pool');
14224
14224
  /** IDs of the spaces the device is in. */
14225
14225
  space_ids: string[];
14226
14226
  /** Optional nickname to describe the device, settable through Seam. */
@@ -15079,22 +15079,16 @@ export type Routes = {
15079
15079
  /** Models of the speakers bonded to this speaker, such as surrounds or a subwoofer. */
15080
15080
  bonded_member_models?: (string[] | undefined) | undefined;
15081
15081
  } | undefined) | undefined;
15082
- /** Metadata for a Hayward OmniLogic pool controller or body of water. */
15082
+ /** Metadata for a Hayward OmniLogic pool controller, pool, or spa. */
15083
15083
  hayward_omnilogic_metadata?: ({
15084
- /** ID of the Hayward OmniLogic system (the controller, called an MSP by Hayward) that the device belongs to. */
15084
+ /** ID of the Hayward OmniLogic controller that the device belongs to. */
15085
15085
  msp_system_id?: (string | undefined) | undefined;
15086
- /** Name of the system, as set in the Hayward OmniLogic app. */
15086
+ /** Name of the controller, as set in the Hayward OmniLogic app. */
15087
15087
  backyard_name?: (string | undefined) | undefined;
15088
- /** ID of the body of water within its system. Only present on a pool or spa body. */
15089
- body_of_water_id?: (string | undefined) | undefined;
15090
- /** Name of the body of water, as set in the Hayward OmniLogic app. Only present on a pool or spa body. */
15091
- body_of_water_name?: (string | undefined) | undefined;
15092
- /** ID of the virtual heater that carries the set point and heating request for the body of water. Only present on a pool or spa body. */
15093
- virtual_heater_id?: (string | undefined) | undefined;
15094
- /** Indicates whether the body of water shares its pump and heater with another body of water in the same system. */
15095
- is_shared_equipment?: (boolean | undefined) | undefined;
15096
- /** Priority of the body of water when it shares equipment. The `high` priority body, usually the spa, takes the shared heater when both request heat. */
15097
- shared_equipment_priority?: (('high' | 'low') | undefined) | undefined;
15088
+ /** ID of the pool or spa within its controller. Only present on a pool or spa. */
15089
+ system_id?: (string | undefined) | undefined;
15090
+ /** Name of the pool or spa, as set in the Hayward OmniLogic app. Only present on a pool or spa. */
15091
+ system_name?: (string | undefined) | undefined;
15098
15092
  } | undefined) | undefined;
15099
15093
  }) & ({
15100
15094
  /** Constraints on access codes for the device. Seam represents each constraint as an object with a `constraint_type` property. Depending on the constraint type, there may also be additional properties. Note that some constraints are manufacturer- or device-specific. */
@@ -15172,7 +15166,8 @@ export type Routes = {
15172
15166
  has_native_entry_events?: (boolean | undefined) | undefined;
15173
15167
  /** Indicates whether the lock is locked. */
15174
15168
  locked?: (boolean | undefined) | undefined;
15175
- /** Keypad battery status. */
15169
+ /** Keypad battery status.
15170
+ * @deprecated Use `accessory_keypad.battery` instead.*/
15176
15171
  keypad_battery?: ({
15177
15172
  /**
15178
15173
  Keypad battery charge level.
@@ -19871,16 +19866,16 @@ export type Routes = {
19871
19866
  result: null;
19872
19867
  /** Errors associated with the action attempt. Null for pending action attempts. */
19873
19868
  error: null;
19874
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
19875
- action_type: 'SET_POOL_HEATING';
19869
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
19870
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
19876
19871
  } | {
19877
19872
  /** ID of the action attempt. */
19878
19873
  action_attempt_id: string;
19879
19874
  status: 'success';
19880
19875
  /** Errors associated with the action attempt. Null for successful action attempts. */
19881
19876
  error: null;
19882
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
19883
- action_type: 'SET_POOL_HEATING';
19877
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
19878
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
19884
19879
  /** Result of the action. */
19885
19880
  result: {};
19886
19881
  } | {
@@ -19889,8 +19884,8 @@ export type Routes = {
19889
19884
  status: 'error';
19890
19885
  /** Result of the action attempt. Null for failed action attempts. */
19891
19886
  result: null;
19892
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
19893
- action_type: 'SET_POOL_HEATING';
19887
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
19888
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
19894
19889
  /** Error associated with the action. */
19895
19890
  error: {
19896
19891
  /** Type of the error. */
@@ -22128,16 +22123,16 @@ export type Routes = {
22128
22123
  result: null;
22129
22124
  /** Errors associated with the action attempt. Null for pending action attempts. */
22130
22125
  error: null;
22131
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
22132
- action_type: 'SET_POOL_HEATING';
22126
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
22127
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
22133
22128
  } | {
22134
22129
  /** ID of the action attempt. */
22135
22130
  action_attempt_id: string;
22136
22131
  status: 'success';
22137
22132
  /** Errors associated with the action attempt. Null for successful action attempts. */
22138
22133
  error: null;
22139
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
22140
- action_type: 'SET_POOL_HEATING';
22134
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
22135
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
22141
22136
  /** Result of the action. */
22142
22137
  result: {};
22143
22138
  } | {
@@ -22146,8 +22141,8 @@ export type Routes = {
22146
22141
  status: 'error';
22147
22142
  /** Result of the action attempt. Null for failed action attempts. */
22148
22143
  result: null;
22149
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
22150
- action_type: 'SET_POOL_HEATING';
22144
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
22145
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
22151
22146
  /** Error associated with the action. */
22152
22147
  error: {
22153
22148
  /** Type of the error. */
@@ -22696,7 +22691,7 @@ export type Routes = {
22696
22691
  /** ID of the device. */
22697
22692
  device_id: string;
22698
22693
  /** Type of the device. The `august_lock` and `yale_lock` values are deprecated. Use `yale_access_lock` in place of `august_lock`, and `yale_access_lock` or `yale_home_lock` in place of `yale_lock`. */
22699
- device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_system' | 'hayward_pool');
22694
+ device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_controller' | 'hayward_pool');
22700
22695
  /** IDs of the spaces the device is in. */
22701
22696
  space_ids: string[];
22702
22697
  /** Optional nickname to describe the device, settable through Seam. */
@@ -23555,22 +23550,16 @@ export type Routes = {
23555
23550
  /** Models of the speakers bonded to this speaker, such as surrounds or a subwoofer. */
23556
23551
  bonded_member_models?: (string[] | undefined) | undefined;
23557
23552
  } | undefined) | undefined;
23558
- /** Metadata for a Hayward OmniLogic pool controller or body of water. */
23553
+ /** Metadata for a Hayward OmniLogic pool controller, pool, or spa. */
23559
23554
  hayward_omnilogic_metadata?: ({
23560
- /** ID of the Hayward OmniLogic system (the controller, called an MSP by Hayward) that the device belongs to. */
23555
+ /** ID of the Hayward OmniLogic controller that the device belongs to. */
23561
23556
  msp_system_id?: (string | undefined) | undefined;
23562
- /** Name of the system, as set in the Hayward OmniLogic app. */
23557
+ /** Name of the controller, as set in the Hayward OmniLogic app. */
23563
23558
  backyard_name?: (string | undefined) | undefined;
23564
- /** ID of the body of water within its system. Only present on a pool or spa body. */
23565
- body_of_water_id?: (string | undefined) | undefined;
23566
- /** Name of the body of water, as set in the Hayward OmniLogic app. Only present on a pool or spa body. */
23567
- body_of_water_name?: (string | undefined) | undefined;
23568
- /** ID of the virtual heater that carries the set point and heating request for the body of water. Only present on a pool or spa body. */
23569
- virtual_heater_id?: (string | undefined) | undefined;
23570
- /** Indicates whether the body of water shares its pump and heater with another body of water in the same system. */
23571
- is_shared_equipment?: (boolean | undefined) | undefined;
23572
- /** Priority of the body of water when it shares equipment. The `high` priority body, usually the spa, takes the shared heater when both request heat. */
23573
- shared_equipment_priority?: (('high' | 'low') | undefined) | undefined;
23559
+ /** ID of the pool or spa within its controller. Only present on a pool or spa. */
23560
+ system_id?: (string | undefined) | undefined;
23561
+ /** Name of the pool or spa, as set in the Hayward OmniLogic app. Only present on a pool or spa. */
23562
+ system_name?: (string | undefined) | undefined;
23574
23563
  } | undefined) | undefined;
23575
23564
  }) & ({
23576
23565
  /** Constraints on access codes for the device. Seam represents each constraint as an object with a `constraint_type` property. Depending on the constraint type, there may also be additional properties. Note that some constraints are manufacturer- or device-specific. */
@@ -23648,7 +23637,8 @@ export type Routes = {
23648
23637
  has_native_entry_events?: (boolean | undefined) | undefined;
23649
23638
  /** Indicates whether the lock is locked. */
23650
23639
  locked?: (boolean | undefined) | undefined;
23651
- /** Keypad battery status. */
23640
+ /** Keypad battery status.
23641
+ * @deprecated Use `accessory_keypad.battery` instead.*/
23652
23642
  keypad_battery?: ({
23653
23643
  /**
23654
23644
  Keypad battery charge level.
@@ -27596,16 +27586,16 @@ export type Routes = {
27596
27586
  result: null;
27597
27587
  /** Errors associated with the action attempt. Null for pending action attempts. */
27598
27588
  error: null;
27599
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
27600
- action_type: 'SET_POOL_HEATING';
27589
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
27590
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
27601
27591
  } | {
27602
27592
  /** ID of the action attempt. */
27603
27593
  action_attempt_id: string;
27604
27594
  status: 'success';
27605
27595
  /** Errors associated with the action attempt. Null for successful action attempts. */
27606
27596
  error: null;
27607
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
27608
- action_type: 'SET_POOL_HEATING';
27597
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
27598
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
27609
27599
  /** Result of the action. */
27610
27600
  result: {};
27611
27601
  } | {
@@ -27614,8 +27604,8 @@ export type Routes = {
27614
27604
  status: 'error';
27615
27605
  /** Result of the action attempt. Null for failed action attempts. */
27616
27606
  result: null;
27617
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
27618
- action_type: 'SET_POOL_HEATING';
27607
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
27608
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
27619
27609
  /** Error associated with the action. */
27620
27610
  error: {
27621
27611
  /** Type of the error. */
@@ -33469,16 +33459,16 @@ export type Routes = {
33469
33459
  result: null;
33470
33460
  /** Errors associated with the action attempt. Null for pending action attempts. */
33471
33461
  error: null;
33472
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
33473
- action_type: 'SET_POOL_HEATING';
33462
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
33463
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
33474
33464
  } | {
33475
33465
  /** ID of the action attempt. */
33476
33466
  action_attempt_id: string;
33477
33467
  status: 'success';
33478
33468
  /** Errors associated with the action attempt. Null for successful action attempts. */
33479
33469
  error: null;
33480
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
33481
- action_type: 'SET_POOL_HEATING';
33470
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
33471
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
33482
33472
  /** Result of the action. */
33483
33473
  result: {};
33484
33474
  } | {
@@ -33487,8 +33477,8 @@ export type Routes = {
33487
33477
  status: 'error';
33488
33478
  /** Result of the action attempt. Null for failed action attempts. */
33489
33479
  result: null;
33490
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
33491
- action_type: 'SET_POOL_HEATING';
33480
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
33481
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
33492
33482
  /** Error associated with the action. */
33493
33483
  error: {
33494
33484
  /** Type of the error. */
@@ -35815,16 +35805,16 @@ export type Routes = {
35815
35805
  result: null;
35816
35806
  /** Errors associated with the action attempt. Null for pending action attempts. */
35817
35807
  error: null;
35818
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
35819
- action_type: 'SET_POOL_HEATING';
35808
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
35809
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
35820
35810
  } | {
35821
35811
  /** ID of the action attempt. */
35822
35812
  action_attempt_id: string;
35823
35813
  status: 'success';
35824
35814
  /** Errors associated with the action attempt. Null for successful action attempts. */
35825
35815
  error: null;
35826
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
35827
- action_type: 'SET_POOL_HEATING';
35816
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
35817
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
35828
35818
  /** Result of the action. */
35829
35819
  result: {};
35830
35820
  } | {
@@ -35833,8 +35823,8 @@ export type Routes = {
35833
35823
  status: 'error';
35834
35824
  /** Result of the action attempt. Null for failed action attempts. */
35835
35825
  result: null;
35836
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
35837
- action_type: 'SET_POOL_HEATING';
35826
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
35827
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
35838
35828
  /** Error associated with the action. */
35839
35829
  error: {
35840
35830
  /** Type of the error. */
@@ -38060,16 +38050,16 @@ export type Routes = {
38060
38050
  result: null;
38061
38051
  /** Errors associated with the action attempt. Null for pending action attempts. */
38062
38052
  error: null;
38063
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
38064
- action_type: 'SET_POOL_HEATING';
38053
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
38054
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
38065
38055
  } | {
38066
38056
  /** ID of the action attempt. */
38067
38057
  action_attempt_id: string;
38068
38058
  status: 'success';
38069
38059
  /** Errors associated with the action attempt. Null for successful action attempts. */
38070
38060
  error: null;
38071
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
38072
- action_type: 'SET_POOL_HEATING';
38061
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
38062
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
38073
38063
  /** Result of the action. */
38074
38064
  result: {};
38075
38065
  } | {
@@ -38078,8 +38068,8 @@ export type Routes = {
38078
38068
  status: 'error';
38079
38069
  /** Result of the action attempt. Null for failed action attempts. */
38080
38070
  result: null;
38081
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
38082
- action_type: 'SET_POOL_HEATING';
38071
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
38072
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
38083
38073
  /** Error associated with the action. */
38084
38074
  error: {
38085
38075
  /** Type of the error. */
@@ -41043,16 +41033,16 @@ export type Routes = {
41043
41033
  result: null;
41044
41034
  /** Errors associated with the action attempt. Null for pending action attempts. */
41045
41035
  error: null;
41046
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
41047
- action_type: 'SET_POOL_HEATING';
41036
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
41037
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
41048
41038
  } | {
41049
41039
  /** ID of the action attempt. */
41050
41040
  action_attempt_id: string;
41051
41041
  status: 'success';
41052
41042
  /** Errors associated with the action attempt. Null for successful action attempts. */
41053
41043
  error: null;
41054
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
41055
- action_type: 'SET_POOL_HEATING';
41044
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
41045
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
41056
41046
  /** Result of the action. */
41057
41047
  result: {};
41058
41048
  } | {
@@ -41061,8 +41051,8 @@ export type Routes = {
41061
41051
  status: 'error';
41062
41052
  /** Result of the action attempt. Null for failed action attempts. */
41063
41053
  result: null;
41064
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
41065
- action_type: 'SET_POOL_HEATING';
41054
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
41055
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
41066
41056
  /** Error associated with the action. */
41067
41057
  error: {
41068
41058
  /** Type of the error. */
@@ -45680,16 +45670,16 @@ export type Routes = {
45680
45670
  result: null;
45681
45671
  /** Errors associated with the action attempt. Null for pending action attempts. */
45682
45672
  error: null;
45683
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
45684
- action_type: 'SET_POOL_HEATING';
45673
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
45674
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
45685
45675
  } | {
45686
45676
  /** ID of the action attempt. */
45687
45677
  action_attempt_id: string;
45688
45678
  status: 'success';
45689
45679
  /** Errors associated with the action attempt. Null for successful action attempts. */
45690
45680
  error: null;
45691
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
45692
- action_type: 'SET_POOL_HEATING';
45681
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
45682
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
45693
45683
  /** Result of the action. */
45694
45684
  result: {};
45695
45685
  } | {
@@ -45698,8 +45688,8 @@ export type Routes = {
45698
45688
  status: 'error';
45699
45689
  /** Result of the action attempt. Null for failed action attempts. */
45700
45690
  result: null;
45701
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
45702
- action_type: 'SET_POOL_HEATING';
45691
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
45692
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
45703
45693
  /** Error associated with the action. */
45704
45694
  error: {
45705
45695
  /** Type of the error. */
@@ -47917,16 +47907,16 @@ export type Routes = {
47917
47907
  result: null;
47918
47908
  /** Errors associated with the action attempt. Null for pending action attempts. */
47919
47909
  error: null;
47920
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
47921
- action_type: 'SET_POOL_HEATING';
47910
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
47911
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
47922
47912
  } | {
47923
47913
  /** ID of the action attempt. */
47924
47914
  action_attempt_id: string;
47925
47915
  status: 'success';
47926
47916
  /** Errors associated with the action attempt. Null for successful action attempts. */
47927
47917
  error: null;
47928
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
47929
- action_type: 'SET_POOL_HEATING';
47918
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
47919
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
47930
47920
  /** Result of the action. */
47931
47921
  result: {};
47932
47922
  } | {
@@ -47935,8 +47925,8 @@ export type Routes = {
47935
47925
  status: 'error';
47936
47926
  /** Result of the action attempt. Null for failed action attempts. */
47937
47927
  result: null;
47938
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
47939
- action_type: 'SET_POOL_HEATING';
47928
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
47929
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
47940
47930
  /** Error associated with the action. */
47941
47931
  error: {
47942
47932
  /** Type of the error. */
@@ -50611,7 +50601,7 @@ export type Routes = {
50611
50601
  /** ID of the device. */
50612
50602
  device_id: string;
50613
50603
  /** Type of the device. The `august_lock` and `yale_lock` values are deprecated. Use `yale_access_lock` in place of `august_lock`, and `yale_access_lock` or `yale_home_lock` in place of `yale_lock`. */
50614
- device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_system' | 'hayward_pool');
50604
+ device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_controller' | 'hayward_pool');
50615
50605
  /** IDs of the spaces the device is in. */
50616
50606
  space_ids: string[];
50617
50607
  /** Optional nickname to describe the device, settable through Seam. */
@@ -51470,22 +51460,16 @@ export type Routes = {
51470
51460
  /** Models of the speakers bonded to this speaker, such as surrounds or a subwoofer. */
51471
51461
  bonded_member_models?: (string[] | undefined) | undefined;
51472
51462
  } | undefined) | undefined;
51473
- /** Metadata for a Hayward OmniLogic pool controller or body of water. */
51463
+ /** Metadata for a Hayward OmniLogic pool controller, pool, or spa. */
51474
51464
  hayward_omnilogic_metadata?: ({
51475
- /** ID of the Hayward OmniLogic system (the controller, called an MSP by Hayward) that the device belongs to. */
51465
+ /** ID of the Hayward OmniLogic controller that the device belongs to. */
51476
51466
  msp_system_id?: (string | undefined) | undefined;
51477
- /** Name of the system, as set in the Hayward OmniLogic app. */
51467
+ /** Name of the controller, as set in the Hayward OmniLogic app. */
51478
51468
  backyard_name?: (string | undefined) | undefined;
51479
- /** ID of the body of water within its system. Only present on a pool or spa body. */
51480
- body_of_water_id?: (string | undefined) | undefined;
51481
- /** Name of the body of water, as set in the Hayward OmniLogic app. Only present on a pool or spa body. */
51482
- body_of_water_name?: (string | undefined) | undefined;
51483
- /** ID of the virtual heater that carries the set point and heating request for the body of water. Only present on a pool or spa body. */
51484
- virtual_heater_id?: (string | undefined) | undefined;
51485
- /** Indicates whether the body of water shares its pump and heater with another body of water in the same system. */
51486
- is_shared_equipment?: (boolean | undefined) | undefined;
51487
- /** Priority of the body of water when it shares equipment. The `high` priority body, usually the spa, takes the shared heater when both request heat. */
51488
- shared_equipment_priority?: (('high' | 'low') | undefined) | undefined;
51469
+ /** ID of the pool or spa within its controller. Only present on a pool or spa. */
51470
+ system_id?: (string | undefined) | undefined;
51471
+ /** Name of the pool or spa, as set in the Hayward OmniLogic app. Only present on a pool or spa. */
51472
+ system_name?: (string | undefined) | undefined;
51489
51473
  } | undefined) | undefined;
51490
51474
  }) & ({
51491
51475
  /** Constraints on access codes for the device. Seam represents each constraint as an object with a `constraint_type` property. Depending on the constraint type, there may also be additional properties. Note that some constraints are manufacturer- or device-specific. */
@@ -51563,7 +51547,8 @@ export type Routes = {
51563
51547
  has_native_entry_events?: (boolean | undefined) | undefined;
51564
51548
  /** Indicates whether the lock is locked. */
51565
51549
  locked?: (boolean | undefined) | undefined;
51566
- /** Keypad battery status. */
51550
+ /** Keypad battery status.
51551
+ * @deprecated Use `accessory_keypad.battery` instead.*/
51567
51552
  keypad_battery?: ({
51568
51553
  /**
51569
51554
  Keypad battery charge level.
@@ -52449,9 +52434,9 @@ export type Routes = {
52449
52434
  /** ID of the Connect Webview for which you want to list devices. */
52450
52435
  connect_webview_id?: string | undefined;
52451
52436
  /** Device type for which you want to list devices. */
52452
- device_type?: (('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_system' | 'hayward_pool')) | undefined;
52437
+ device_type?: (('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_controller' | 'hayward_pool')) | undefined;
52453
52438
  /** Array of device types for which you want to list devices. */
52454
- device_types?: (('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_system' | 'hayward_pool'))[] | undefined;
52439
+ device_types?: (('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_controller' | 'hayward_pool'))[] | undefined;
52455
52440
  /** Manufacturer for which you want to list devices. */
52456
52441
  manufacturer?: ('akuvox' | 'august' | 'avigilon_alta' | 'brivo' | 'butterflymx' | 'doorking' | 'four_suites' | 'genie' | 'igloo' | 'keywe' | 'kwikset' | 'linear' | 'nuki' | 'philia' | 'salto' | 'samsung' | 'schlage' | 'seam' | 'unknown' | 'wyze' | 'yale' | 'two_n' | 'ttlock' | 'igloohome' | 'controlbyweb' | 'tedee' | 'keyincode' | 'ubiquiti' | 'akiles' | 'aqara' | 'ecobee' | 'eufy' | 'dormakaba_oracode' | 'dormakaba_oracode_iho' | 'honeywell_resideo' | 'keynest' | 'korelock' | 'lockly' | 'minut' | 'nest' | 'noiseaware' | 'sensi' | 'sensibo' | 'smartthings' | 'tado' | 'ultraloq' | 'ring' | 'tapo' | 'arlo' | 'reolink' | 'unifi_protect' | 'yale_connect' | 'alertify' | 'ical' | 'lodgify' | 'hostaway' | 'guesty' | 'acuity_scheduling' | 'omnitec' | 'kisi' | 'slack' | 'yacan' | 'sonos' | 'hayward_omnilogic' | 'tuya') | undefined;
52457
52442
  /** Array of device IDs for which you want to list devices. */
@@ -52479,8 +52464,8 @@ export type Routes = {
52479
52464
  space_id?: string | undefined;
52480
52465
  /** String for which to search. Filters returned devices to include all records that satisfy a partial match using `device_id` (full or partial UUID prefix, minimum 4 characters), `connected_account_id`, `display_name`, `custom_metadata` or `location.location_name`. */
52481
52466
  search?: string | undefined;
52482
- /** ID of the parent device whose child devices you want to list. */
52483
- parent_device_id?: string | undefined;
52467
+ /** ID of the parent device whose child devices you want to list. Specify `null` to list devices that have no parent device. */
52468
+ parent_device_id?: (string | null) | undefined;
52484
52469
  };
52485
52470
  formData: {};
52486
52471
  jsonResponse: {
@@ -52488,7 +52473,7 @@ export type Routes = {
52488
52473
  /** ID of the device. */
52489
52474
  device_id: string;
52490
52475
  /** Type of the device. The `august_lock` and `yale_lock` values are deprecated. Use `yale_access_lock` in place of `august_lock`, and `yale_access_lock` or `yale_home_lock` in place of `yale_lock`. */
52491
- device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_system' | 'hayward_pool');
52476
+ device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_controller' | 'hayward_pool');
52492
52477
  /** IDs of the spaces the device is in. */
52493
52478
  space_ids: string[];
52494
52479
  /** Optional nickname to describe the device, settable through Seam. */
@@ -53347,22 +53332,16 @@ export type Routes = {
53347
53332
  /** Models of the speakers bonded to this speaker, such as surrounds or a subwoofer. */
53348
53333
  bonded_member_models?: (string[] | undefined) | undefined;
53349
53334
  } | undefined) | undefined;
53350
- /** Metadata for a Hayward OmniLogic pool controller or body of water. */
53335
+ /** Metadata for a Hayward OmniLogic pool controller, pool, or spa. */
53351
53336
  hayward_omnilogic_metadata?: ({
53352
- /** ID of the Hayward OmniLogic system (the controller, called an MSP by Hayward) that the device belongs to. */
53337
+ /** ID of the Hayward OmniLogic controller that the device belongs to. */
53353
53338
  msp_system_id?: (string | undefined) | undefined;
53354
- /** Name of the system, as set in the Hayward OmniLogic app. */
53339
+ /** Name of the controller, as set in the Hayward OmniLogic app. */
53355
53340
  backyard_name?: (string | undefined) | undefined;
53356
- /** ID of the body of water within its system. Only present on a pool or spa body. */
53357
- body_of_water_id?: (string | undefined) | undefined;
53358
- /** Name of the body of water, as set in the Hayward OmniLogic app. Only present on a pool or spa body. */
53359
- body_of_water_name?: (string | undefined) | undefined;
53360
- /** ID of the virtual heater that carries the set point and heating request for the body of water. Only present on a pool or spa body. */
53361
- virtual_heater_id?: (string | undefined) | undefined;
53362
- /** Indicates whether the body of water shares its pump and heater with another body of water in the same system. */
53363
- is_shared_equipment?: (boolean | undefined) | undefined;
53364
- /** Priority of the body of water when it shares equipment. The `high` priority body, usually the spa, takes the shared heater when both request heat. */
53365
- shared_equipment_priority?: (('high' | 'low') | undefined) | undefined;
53341
+ /** ID of the pool or spa within its controller. Only present on a pool or spa. */
53342
+ system_id?: (string | undefined) | undefined;
53343
+ /** Name of the pool or spa, as set in the Hayward OmniLogic app. Only present on a pool or spa. */
53344
+ system_name?: (string | undefined) | undefined;
53366
53345
  } | undefined) | undefined;
53367
53346
  }) & ({
53368
53347
  /** Constraints on access codes for the device. Seam represents each constraint as an object with a `constraint_type` property. Depending on the constraint type, there may also be additional properties. Note that some constraints are manufacturer- or device-specific. */
@@ -53440,7 +53419,8 @@ export type Routes = {
53440
53419
  has_native_entry_events?: (boolean | undefined) | undefined;
53441
53420
  /** Indicates whether the lock is locked. */
53442
53421
  locked?: (boolean | undefined) | undefined;
53443
- /** Keypad battery status. */
53422
+ /** Keypad battery status.
53423
+ * @deprecated Use `accessory_keypad.battery` instead.*/
53444
53424
  keypad_battery?: ({
53445
53425
  /**
53446
53426
  Keypad battery charge level.
@@ -54533,7 +54513,7 @@ export type Routes = {
54533
54513
  /** ID of the device. */
54534
54514
  device_id: string;
54535
54515
  /** Type of the device. The `august_lock` and `yale_lock` values are deprecated. Use `yale_access_lock` in place of `august_lock`, and `yale_access_lock` or `yale_home_lock` in place of `yale_lock`. */
54536
- device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_system' | 'hayward_pool');
54516
+ device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_controller' | 'hayward_pool');
54537
54517
  /** Unique identifier for the account associated with the device. */
54538
54518
  connected_account_id: string;
54539
54519
  /** Location information for the device. */
@@ -55081,9 +55061,9 @@ export type Routes = {
55081
55061
  /** ID of the Connect Webview for which you want to list devices. */
55082
55062
  connect_webview_id?: string | undefined;
55083
55063
  /** Device type for which you want to list devices. */
55084
- device_type?: (('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_system' | 'hayward_pool')) | undefined;
55064
+ device_type?: (('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_controller' | 'hayward_pool')) | undefined;
55085
55065
  /** Array of device types for which you want to list devices. */
55086
- device_types?: (('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_system' | 'hayward_pool'))[] | undefined;
55066
+ device_types?: (('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_controller' | 'hayward_pool'))[] | undefined;
55087
55067
  /** Manufacturer for which you want to list devices. */
55088
55068
  manufacturer?: ('akuvox' | 'august' | 'avigilon_alta' | 'brivo' | 'butterflymx' | 'doorking' | 'four_suites' | 'genie' | 'igloo' | 'keywe' | 'kwikset' | 'linear' | 'nuki' | 'philia' | 'salto' | 'samsung' | 'schlage' | 'seam' | 'unknown' | 'wyze' | 'yale' | 'two_n' | 'ttlock' | 'igloohome' | 'controlbyweb' | 'tedee' | 'keyincode' | 'ubiquiti' | 'akiles' | 'aqara' | 'ecobee' | 'eufy' | 'dormakaba_oracode' | 'dormakaba_oracode_iho' | 'honeywell_resideo' | 'keynest' | 'korelock' | 'lockly' | 'minut' | 'nest' | 'noiseaware' | 'sensi' | 'sensibo' | 'smartthings' | 'tado' | 'ultraloq' | 'ring' | 'tapo' | 'arlo' | 'reolink' | 'unifi_protect' | 'yale_connect' | 'alertify' | 'ical' | 'lodgify' | 'hostaway' | 'guesty' | 'acuity_scheduling' | 'omnitec' | 'kisi' | 'slack' | 'yacan' | 'sonos' | 'hayward_omnilogic' | 'tuya') | undefined;
55089
55069
  /** Array of device IDs for which you want to list devices. */
@@ -55098,8 +55078,8 @@ export type Routes = {
55098
55078
  exclude_if?: ('can_remotely_unlock' | 'can_remotely_lock' | 'can_program_offline_access_codes' | 'can_program_online_access_codes' | 'can_hvac_heat' | 'can_hvac_cool' | 'can_hvac_heat_cool' | 'can_turn_off_hvac' | 'can_activate_weekly_program' | 'can_simulate_removal' | 'can_simulate_connection' | 'can_simulate_disconnection' | 'can_unlock_with_code' | 'can_run_thermostat_programs' | 'can_program_thermostat_programs_as_weekday_weekend' | 'can_program_thermostat_programs_as_different_each_day' | 'can_program_thermostat_programs_as_same_each_day' | 'can_simulate_hub_connection' | 'can_simulate_hub_disconnection' | 'can_simulate_paid_subscription' | 'can_configure_auto_lock' | 'can_stream_live_video' | 'can_set_speaker_volume' | 'can_mute_speaker' | 'can_unmute_speaker' | 'can_pause_speaker_playback' | 'can_resume_speaker_playback' | 'can_play_speaker_chime' | 'can_play_speaker_favorite' | 'can_play_speaker_audio_clip' | 'can_control_temperature')[] | undefined;
55099
55079
  /** String for which to search. Filters returned devices to include all records that satisfy a partial match using `device_id` (full or partial UUID prefix, minimum 4 characters), `connected_account_id`, `display_name`, `custom_metadata` or `location.location_name`. */
55100
55080
  search?: string | undefined;
55101
- /** ID of the parent device whose child devices you want to list. */
55102
- parent_device_id?: string | undefined;
55081
+ /** ID of the parent device whose child devices you want to list. Specify `null` to list devices that have no parent device. */
55082
+ parent_device_id?: (string | null) | undefined;
55103
55083
  /** Numerical limit on the number of devices to return. */
55104
55084
  limit?: number;
55105
55085
  };
@@ -55109,7 +55089,7 @@ export type Routes = {
55109
55089
  /** ID of the device. */
55110
55090
  device_id: string;
55111
55091
  /** Type of the device. The `august_lock` and `yale_lock` values are deprecated. Use `yale_access_lock` in place of `august_lock`, and `yale_access_lock` or `yale_home_lock` in place of `yale_lock`. */
55112
- device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_system' | 'hayward_pool');
55092
+ device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_controller' | 'hayward_pool');
55113
55093
  /** Unique identifier for the account associated with the device. */
55114
55094
  connected_account_id: string;
55115
55095
  /** Location information for the device. */
@@ -65365,16 +65345,16 @@ export type Routes = {
65365
65345
  result: null;
65366
65346
  /** Errors associated with the action attempt. Null for pending action attempts. */
65367
65347
  error: null;
65368
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
65369
- action_type: 'SET_POOL_HEATING';
65348
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
65349
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
65370
65350
  } | {
65371
65351
  /** ID of the action attempt. */
65372
65352
  action_attempt_id: string;
65373
65353
  status: 'success';
65374
65354
  /** Errors associated with the action attempt. Null for successful action attempts. */
65375
65355
  error: null;
65376
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
65377
- action_type: 'SET_POOL_HEATING';
65356
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
65357
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
65378
65358
  /** Result of the action. */
65379
65359
  result: {};
65380
65360
  } | {
@@ -65383,8 +65363,8 @@ export type Routes = {
65383
65363
  status: 'error';
65384
65364
  /** Result of the action attempt. Null for failed action attempts. */
65385
65365
  result: null;
65386
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
65387
- action_type: 'SET_POOL_HEATING';
65366
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
65367
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
65388
65368
  /** Error associated with the action. */
65389
65369
  error: {
65390
65370
  /** Type of the error. */
@@ -65679,7 +65659,7 @@ export type Routes = {
65679
65659
  /** ID of the device. */
65680
65660
  device_id: string;
65681
65661
  /** Type of the device. The `august_lock` and `yale_lock` values are deprecated. Use `yale_access_lock` in place of `august_lock`, and `yale_access_lock` or `yale_home_lock` in place of `yale_lock`. */
65682
- device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_system' | 'hayward_pool');
65662
+ device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_controller' | 'hayward_pool');
65683
65663
  /** IDs of the spaces the device is in. */
65684
65664
  space_ids: string[];
65685
65665
  /** Optional nickname to describe the device, settable through Seam. */
@@ -66538,22 +66518,16 @@ export type Routes = {
66538
66518
  /** Models of the speakers bonded to this speaker, such as surrounds or a subwoofer. */
66539
66519
  bonded_member_models?: (string[] | undefined) | undefined;
66540
66520
  } | undefined) | undefined;
66541
- /** Metadata for a Hayward OmniLogic pool controller or body of water. */
66521
+ /** Metadata for a Hayward OmniLogic pool controller, pool, or spa. */
66542
66522
  hayward_omnilogic_metadata?: ({
66543
- /** ID of the Hayward OmniLogic system (the controller, called an MSP by Hayward) that the device belongs to. */
66523
+ /** ID of the Hayward OmniLogic controller that the device belongs to. */
66544
66524
  msp_system_id?: (string | undefined) | undefined;
66545
- /** Name of the system, as set in the Hayward OmniLogic app. */
66525
+ /** Name of the controller, as set in the Hayward OmniLogic app. */
66546
66526
  backyard_name?: (string | undefined) | undefined;
66547
- /** ID of the body of water within its system. Only present on a pool or spa body. */
66548
- body_of_water_id?: (string | undefined) | undefined;
66549
- /** Name of the body of water, as set in the Hayward OmniLogic app. Only present on a pool or spa body. */
66550
- body_of_water_name?: (string | undefined) | undefined;
66551
- /** ID of the virtual heater that carries the set point and heating request for the body of water. Only present on a pool or spa body. */
66552
- virtual_heater_id?: (string | undefined) | undefined;
66553
- /** Indicates whether the body of water shares its pump and heater with another body of water in the same system. */
66554
- is_shared_equipment?: (boolean | undefined) | undefined;
66555
- /** Priority of the body of water when it shares equipment. The `high` priority body, usually the spa, takes the shared heater when both request heat. */
66556
- shared_equipment_priority?: (('high' | 'low') | undefined) | undefined;
66527
+ /** ID of the pool or spa within its controller. Only present on a pool or spa. */
66528
+ system_id?: (string | undefined) | undefined;
66529
+ /** Name of the pool or spa, as set in the Hayward OmniLogic app. Only present on a pool or spa. */
66530
+ system_name?: (string | undefined) | undefined;
66557
66531
  } | undefined) | undefined;
66558
66532
  }) & ({
66559
66533
  /** Constraints on access codes for the device. Seam represents each constraint as an object with a `constraint_type` property. Depending on the constraint type, there may also be additional properties. Note that some constraints are manufacturer- or device-specific. */
@@ -66631,7 +66605,8 @@ export type Routes = {
66631
66605
  has_native_entry_events?: (boolean | undefined) | undefined;
66632
66606
  /** Indicates whether the lock is locked. */
66633
66607
  locked?: (boolean | undefined) | undefined;
66634
- /** Keypad battery status. */
66608
+ /** Keypad battery status.
66609
+ * @deprecated Use `accessory_keypad.battery` instead.*/
66635
66610
  keypad_battery?: ({
66636
66611
  /**
66637
66612
  Keypad battery charge level.
@@ -67504,7 +67479,7 @@ export type Routes = {
67504
67479
  /** ID of the device. */
67505
67480
  device_id: string;
67506
67481
  /** Type of the device. The `august_lock` and `yale_lock` values are deprecated. Use `yale_access_lock` in place of `august_lock`, and `yale_access_lock` or `yale_home_lock` in place of `yale_lock`. */
67507
- device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_system' | 'hayward_pool');
67482
+ device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_controller' | 'hayward_pool');
67508
67483
  /** IDs of the spaces the device is in. */
67509
67484
  space_ids: string[];
67510
67485
  /** Optional nickname to describe the device, settable through Seam. */
@@ -68363,22 +68338,16 @@ export type Routes = {
68363
68338
  /** Models of the speakers bonded to this speaker, such as surrounds or a subwoofer. */
68364
68339
  bonded_member_models?: (string[] | undefined) | undefined;
68365
68340
  } | undefined) | undefined;
68366
- /** Metadata for a Hayward OmniLogic pool controller or body of water. */
68341
+ /** Metadata for a Hayward OmniLogic pool controller, pool, or spa. */
68367
68342
  hayward_omnilogic_metadata?: ({
68368
- /** ID of the Hayward OmniLogic system (the controller, called an MSP by Hayward) that the device belongs to. */
68343
+ /** ID of the Hayward OmniLogic controller that the device belongs to. */
68369
68344
  msp_system_id?: (string | undefined) | undefined;
68370
- /** Name of the system, as set in the Hayward OmniLogic app. */
68345
+ /** Name of the controller, as set in the Hayward OmniLogic app. */
68371
68346
  backyard_name?: (string | undefined) | undefined;
68372
- /** ID of the body of water within its system. Only present on a pool or spa body. */
68373
- body_of_water_id?: (string | undefined) | undefined;
68374
- /** Name of the body of water, as set in the Hayward OmniLogic app. Only present on a pool or spa body. */
68375
- body_of_water_name?: (string | undefined) | undefined;
68376
- /** ID of the virtual heater that carries the set point and heating request for the body of water. Only present on a pool or spa body. */
68377
- virtual_heater_id?: (string | undefined) | undefined;
68378
- /** Indicates whether the body of water shares its pump and heater with another body of water in the same system. */
68379
- is_shared_equipment?: (boolean | undefined) | undefined;
68380
- /** Priority of the body of water when it shares equipment. The `high` priority body, usually the spa, takes the shared heater when both request heat. */
68381
- shared_equipment_priority?: (('high' | 'low') | undefined) | undefined;
68347
+ /** ID of the pool or spa within its controller. Only present on a pool or spa. */
68348
+ system_id?: (string | undefined) | undefined;
68349
+ /** Name of the pool or spa, as set in the Hayward OmniLogic app. Only present on a pool or spa. */
68350
+ system_name?: (string | undefined) | undefined;
68382
68351
  } | undefined) | undefined;
68383
68352
  }) & ({
68384
68353
  /** Constraints on access codes for the device. Seam represents each constraint as an object with a `constraint_type` property. Depending on the constraint type, there may also be additional properties. Note that some constraints are manufacturer- or device-specific. */
@@ -68456,7 +68425,8 @@ export type Routes = {
68456
68425
  has_native_entry_events?: (boolean | undefined) | undefined;
68457
68426
  /** Indicates whether the lock is locked. */
68458
68427
  locked?: (boolean | undefined) | undefined;
68459
- /** Keypad battery status. */
68428
+ /** Keypad battery status.
68429
+ * @deprecated Use `accessory_keypad.battery` instead.*/
68460
68430
  keypad_battery?: ({
68461
68431
  /**
68462
68432
  Keypad battery charge level.
@@ -69352,7 +69322,7 @@ export type Routes = {
69352
69322
  /** ID of the device. */
69353
69323
  device_id: string;
69354
69324
  /** Type of the device. The `august_lock` and `yale_lock` values are deprecated. Use `yale_access_lock` in place of `august_lock`, and `yale_access_lock` or `yale_home_lock` in place of `yale_lock`. */
69355
- device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_system' | 'hayward_pool');
69325
+ device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_controller' | 'hayward_pool');
69356
69326
  /** IDs of the spaces the device is in. */
69357
69327
  space_ids: string[];
69358
69328
  /** Optional nickname to describe the device, settable through Seam. */
@@ -70211,22 +70181,16 @@ export type Routes = {
70211
70181
  /** Models of the speakers bonded to this speaker, such as surrounds or a subwoofer. */
70212
70182
  bonded_member_models?: (string[] | undefined) | undefined;
70213
70183
  } | undefined) | undefined;
70214
- /** Metadata for a Hayward OmniLogic pool controller or body of water. */
70184
+ /** Metadata for a Hayward OmniLogic pool controller, pool, or spa. */
70215
70185
  hayward_omnilogic_metadata?: ({
70216
- /** ID of the Hayward OmniLogic system (the controller, called an MSP by Hayward) that the device belongs to. */
70186
+ /** ID of the Hayward OmniLogic controller that the device belongs to. */
70217
70187
  msp_system_id?: (string | undefined) | undefined;
70218
- /** Name of the system, as set in the Hayward OmniLogic app. */
70188
+ /** Name of the controller, as set in the Hayward OmniLogic app. */
70219
70189
  backyard_name?: (string | undefined) | undefined;
70220
- /** ID of the body of water within its system. Only present on a pool or spa body. */
70221
- body_of_water_id?: (string | undefined) | undefined;
70222
- /** Name of the body of water, as set in the Hayward OmniLogic app. Only present on a pool or spa body. */
70223
- body_of_water_name?: (string | undefined) | undefined;
70224
- /** ID of the virtual heater that carries the set point and heating request for the body of water. Only present on a pool or spa body. */
70225
- virtual_heater_id?: (string | undefined) | undefined;
70226
- /** Indicates whether the body of water shares its pump and heater with another body of water in the same system. */
70227
- is_shared_equipment?: (boolean | undefined) | undefined;
70228
- /** Priority of the body of water when it shares equipment. The `high` priority body, usually the spa, takes the shared heater when both request heat. */
70229
- shared_equipment_priority?: (('high' | 'low') | undefined) | undefined;
70190
+ /** ID of the pool or spa within its controller. Only present on a pool or spa. */
70191
+ system_id?: (string | undefined) | undefined;
70192
+ /** Name of the pool or spa, as set in the Hayward OmniLogic app. Only present on a pool or spa. */
70193
+ system_name?: (string | undefined) | undefined;
70230
70194
  } | undefined) | undefined;
70231
70195
  }) & ({
70232
70196
  /** Constraints on access codes for the device. Seam represents each constraint as an object with a `constraint_type` property. Depending on the constraint type, there may also be additional properties. Note that some constraints are manufacturer- or device-specific. */
@@ -70304,7 +70268,8 @@ export type Routes = {
70304
70268
  has_native_entry_events?: (boolean | undefined) | undefined;
70305
70269
  /** Indicates whether the lock is locked. */
70306
70270
  locked?: (boolean | undefined) | undefined;
70307
- /** Keypad battery status. */
70271
+ /** Keypad battery status.
70272
+ * @deprecated Use `accessory_keypad.battery` instead.*/
70308
70273
  keypad_battery?: ({
70309
70274
  /**
70310
70275
  Keypad battery charge level.
@@ -71176,7 +71141,7 @@ export type Routes = {
71176
71141
  /** ID of the device. */
71177
71142
  device_id: string;
71178
71143
  /** Type of the device. The `august_lock` and `yale_lock` values are deprecated. Use `yale_access_lock` in place of `august_lock`, and `yale_access_lock` or `yale_home_lock` in place of `yale_lock`. */
71179
- device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_system' | 'hayward_pool');
71144
+ device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_controller' | 'hayward_pool');
71180
71145
  /** IDs of the spaces the device is in. */
71181
71146
  space_ids: string[];
71182
71147
  /** Optional nickname to describe the device, settable through Seam. */
@@ -72035,22 +72000,16 @@ export type Routes = {
72035
72000
  /** Models of the speakers bonded to this speaker, such as surrounds or a subwoofer. */
72036
72001
  bonded_member_models?: (string[] | undefined) | undefined;
72037
72002
  } | undefined) | undefined;
72038
- /** Metadata for a Hayward OmniLogic pool controller or body of water. */
72003
+ /** Metadata for a Hayward OmniLogic pool controller, pool, or spa. */
72039
72004
  hayward_omnilogic_metadata?: ({
72040
- /** ID of the Hayward OmniLogic system (the controller, called an MSP by Hayward) that the device belongs to. */
72005
+ /** ID of the Hayward OmniLogic controller that the device belongs to. */
72041
72006
  msp_system_id?: (string | undefined) | undefined;
72042
- /** Name of the system, as set in the Hayward OmniLogic app. */
72007
+ /** Name of the controller, as set in the Hayward OmniLogic app. */
72043
72008
  backyard_name?: (string | undefined) | undefined;
72044
- /** ID of the body of water within its system. Only present on a pool or spa body. */
72045
- body_of_water_id?: (string | undefined) | undefined;
72046
- /** Name of the body of water, as set in the Hayward OmniLogic app. Only present on a pool or spa body. */
72047
- body_of_water_name?: (string | undefined) | undefined;
72048
- /** ID of the virtual heater that carries the set point and heating request for the body of water. Only present on a pool or spa body. */
72049
- virtual_heater_id?: (string | undefined) | undefined;
72050
- /** Indicates whether the body of water shares its pump and heater with another body of water in the same system. */
72051
- is_shared_equipment?: (boolean | undefined) | undefined;
72052
- /** Priority of the body of water when it shares equipment. The `high` priority body, usually the spa, takes the shared heater when both request heat. */
72053
- shared_equipment_priority?: (('high' | 'low') | undefined) | undefined;
72009
+ /** ID of the pool or spa within its controller. Only present on a pool or spa. */
72010
+ system_id?: (string | undefined) | undefined;
72011
+ /** Name of the pool or spa, as set in the Hayward OmniLogic app. Only present on a pool or spa. */
72012
+ system_name?: (string | undefined) | undefined;
72054
72013
  } | undefined) | undefined;
72055
72014
  }) & ({
72056
72015
  /** Constraints on access codes for the device. Seam represents each constraint as an object with a `constraint_type` property. Depending on the constraint type, there may also be additional properties. Note that some constraints are manufacturer- or device-specific. */
@@ -72128,7 +72087,8 @@ export type Routes = {
72128
72087
  has_native_entry_events?: (boolean | undefined) | undefined;
72129
72088
  /** Indicates whether the lock is locked. */
72130
72089
  locked?: (boolean | undefined) | undefined;
72131
- /** Keypad battery status. */
72090
+ /** Keypad battery status.
72091
+ * @deprecated Use `accessory_keypad.battery` instead.*/
72132
72092
  keypad_battery?: ({
72133
72093
  /**
72134
72094
  Keypad battery charge level.
@@ -74939,16 +74899,16 @@ export type Routes = {
74939
74899
  result: null;
74940
74900
  /** Errors associated with the action attempt. Null for pending action attempts. */
74941
74901
  error: null;
74942
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
74943
- action_type: 'SET_POOL_HEATING';
74902
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
74903
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
74944
74904
  } | {
74945
74905
  /** ID of the action attempt. */
74946
74906
  action_attempt_id: string;
74947
74907
  status: 'success';
74948
74908
  /** Errors associated with the action attempt. Null for successful action attempts. */
74949
74909
  error: null;
74950
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
74951
- action_type: 'SET_POOL_HEATING';
74910
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
74911
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
74952
74912
  /** Result of the action. */
74953
74913
  result: {};
74954
74914
  } | {
@@ -74957,8 +74917,8 @@ export type Routes = {
74957
74917
  status: 'error';
74958
74918
  /** Result of the action attempt. Null for failed action attempts. */
74959
74919
  result: null;
74960
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
74961
- action_type: 'SET_POOL_HEATING';
74920
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
74921
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
74962
74922
  /** Error associated with the action. */
74963
74923
  error: {
74964
74924
  /** Type of the error. */
@@ -77177,16 +77137,16 @@ export type Routes = {
77177
77137
  result: null;
77178
77138
  /** Errors associated with the action attempt. Null for pending action attempts. */
77179
77139
  error: null;
77180
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
77181
- action_type: 'SET_POOL_HEATING';
77140
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
77141
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
77182
77142
  } | {
77183
77143
  /** ID of the action attempt. */
77184
77144
  action_attempt_id: string;
77185
77145
  status: 'success';
77186
77146
  /** Errors associated with the action attempt. Null for successful action attempts. */
77187
77147
  error: null;
77188
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
77189
- action_type: 'SET_POOL_HEATING';
77148
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
77149
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
77190
77150
  /** Result of the action. */
77191
77151
  result: {};
77192
77152
  } | {
@@ -77195,8 +77155,8 @@ export type Routes = {
77195
77155
  status: 'error';
77196
77156
  /** Result of the action attempt. Null for failed action attempts. */
77197
77157
  result: null;
77198
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
77199
- action_type: 'SET_POOL_HEATING';
77158
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
77159
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
77200
77160
  /** Error associated with the action. */
77201
77161
  error: {
77202
77162
  /** Type of the error. */
@@ -79413,16 +79373,16 @@ export type Routes = {
79413
79373
  result: null;
79414
79374
  /** Errors associated with the action attempt. Null for pending action attempts. */
79415
79375
  error: null;
79416
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
79417
- action_type: 'SET_POOL_HEATING';
79376
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
79377
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
79418
79378
  } | {
79419
79379
  /** ID of the action attempt. */
79420
79380
  action_attempt_id: string;
79421
79381
  status: 'success';
79422
79382
  /** Errors associated with the action attempt. Null for successful action attempts. */
79423
79383
  error: null;
79424
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
79425
- action_type: 'SET_POOL_HEATING';
79384
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
79385
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
79426
79386
  /** Result of the action. */
79427
79387
  result: {};
79428
79388
  } | {
@@ -79431,8 +79391,8 @@ export type Routes = {
79431
79391
  status: 'error';
79432
79392
  /** Result of the action attempt. Null for failed action attempts. */
79433
79393
  result: null;
79434
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
79435
- action_type: 'SET_POOL_HEATING';
79394
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
79395
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
79436
79396
  /** Error associated with the action. */
79437
79397
  error: {
79438
79398
  /** Type of the error. */
@@ -81649,16 +81609,16 @@ export type Routes = {
81649
81609
  result: null;
81650
81610
  /** Errors associated with the action attempt. Null for pending action attempts. */
81651
81611
  error: null;
81652
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
81653
- action_type: 'SET_POOL_HEATING';
81612
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
81613
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
81654
81614
  } | {
81655
81615
  /** ID of the action attempt. */
81656
81616
  action_attempt_id: string;
81657
81617
  status: 'success';
81658
81618
  /** Errors associated with the action attempt. Null for successful action attempts. */
81659
81619
  error: null;
81660
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
81661
- action_type: 'SET_POOL_HEATING';
81620
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
81621
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
81662
81622
  /** Result of the action. */
81663
81623
  result: {};
81664
81624
  } | {
@@ -81667,8 +81627,8 @@ export type Routes = {
81667
81627
  status: 'error';
81668
81628
  /** Result of the action attempt. Null for failed action attempts. */
81669
81629
  result: null;
81670
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
81671
- action_type: 'SET_POOL_HEATING';
81630
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
81631
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
81672
81632
  /** Error associated with the action. */
81673
81633
  error: {
81674
81634
  /** Type of the error. */
@@ -82011,7 +81971,7 @@ export type Routes = {
82011
81971
  /** ID of the device. */
82012
81972
  device_id: string;
82013
81973
  /** Type of the device. The `august_lock` and `yale_lock` values are deprecated. Use `yale_access_lock` in place of `august_lock`, and `yale_access_lock` or `yale_home_lock` in place of `yale_lock`. */
82014
- device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_system' | 'hayward_pool');
81974
+ device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_controller' | 'hayward_pool');
82015
81975
  /** IDs of the spaces the device is in. */
82016
81976
  space_ids: string[];
82017
81977
  /** Optional nickname to describe the device, settable through Seam. */
@@ -82870,22 +82830,16 @@ export type Routes = {
82870
82830
  /** Models of the speakers bonded to this speaker, such as surrounds or a subwoofer. */
82871
82831
  bonded_member_models?: (string[] | undefined) | undefined;
82872
82832
  } | undefined) | undefined;
82873
- /** Metadata for a Hayward OmniLogic pool controller or body of water. */
82833
+ /** Metadata for a Hayward OmniLogic pool controller, pool, or spa. */
82874
82834
  hayward_omnilogic_metadata?: ({
82875
- /** ID of the Hayward OmniLogic system (the controller, called an MSP by Hayward) that the device belongs to. */
82835
+ /** ID of the Hayward OmniLogic controller that the device belongs to. */
82876
82836
  msp_system_id?: (string | undefined) | undefined;
82877
- /** Name of the system, as set in the Hayward OmniLogic app. */
82837
+ /** Name of the controller, as set in the Hayward OmniLogic app. */
82878
82838
  backyard_name?: (string | undefined) | undefined;
82879
- /** ID of the body of water within its system. Only present on a pool or spa body. */
82880
- body_of_water_id?: (string | undefined) | undefined;
82881
- /** Name of the body of water, as set in the Hayward OmniLogic app. Only present on a pool or spa body. */
82882
- body_of_water_name?: (string | undefined) | undefined;
82883
- /** ID of the virtual heater that carries the set point and heating request for the body of water. Only present on a pool or spa body. */
82884
- virtual_heater_id?: (string | undefined) | undefined;
82885
- /** Indicates whether the body of water shares its pump and heater with another body of water in the same system. */
82886
- is_shared_equipment?: (boolean | undefined) | undefined;
82887
- /** Priority of the body of water when it shares equipment. The `high` priority body, usually the spa, takes the shared heater when both request heat. */
82888
- shared_equipment_priority?: (('high' | 'low') | undefined) | undefined;
82839
+ /** ID of the pool or spa within its controller. Only present on a pool or spa. */
82840
+ system_id?: (string | undefined) | undefined;
82841
+ /** Name of the pool or spa, as set in the Hayward OmniLogic app. Only present on a pool or spa. */
82842
+ system_name?: (string | undefined) | undefined;
82889
82843
  } | undefined) | undefined;
82890
82844
  }) & ({
82891
82845
  /** Constraints on access codes for the device. Seam represents each constraint as an object with a `constraint_type` property. Depending on the constraint type, there may also be additional properties. Note that some constraints are manufacturer- or device-specific. */
@@ -82963,7 +82917,8 @@ export type Routes = {
82963
82917
  has_native_entry_events?: (boolean | undefined) | undefined;
82964
82918
  /** Indicates whether the lock is locked. */
82965
82919
  locked?: (boolean | undefined) | undefined;
82966
- /** Keypad battery status. */
82920
+ /** Keypad battery status.
82921
+ * @deprecated Use `accessory_keypad.battery` instead.*/
82967
82922
  keypad_battery?: ({
82968
82923
  /**
82969
82924
  Keypad battery charge level.
@@ -83835,7 +83790,7 @@ export type Routes = {
83835
83790
  /** ID of the device. */
83836
83791
  device_id: string;
83837
83792
  /** Type of the device. The `august_lock` and `yale_lock` values are deprecated. Use `yale_access_lock` in place of `august_lock`, and `yale_access_lock` or `yale_home_lock` in place of `yale_lock`. */
83838
- device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_system' | 'hayward_pool');
83793
+ device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_controller' | 'hayward_pool');
83839
83794
  /** IDs of the spaces the device is in. */
83840
83795
  space_ids: string[];
83841
83796
  /** Optional nickname to describe the device, settable through Seam. */
@@ -84694,22 +84649,16 @@ export type Routes = {
84694
84649
  /** Models of the speakers bonded to this speaker, such as surrounds or a subwoofer. */
84695
84650
  bonded_member_models?: (string[] | undefined) | undefined;
84696
84651
  } | undefined) | undefined;
84697
- /** Metadata for a Hayward OmniLogic pool controller or body of water. */
84652
+ /** Metadata for a Hayward OmniLogic pool controller, pool, or spa. */
84698
84653
  hayward_omnilogic_metadata?: ({
84699
- /** ID of the Hayward OmniLogic system (the controller, called an MSP by Hayward) that the device belongs to. */
84654
+ /** ID of the Hayward OmniLogic controller that the device belongs to. */
84700
84655
  msp_system_id?: (string | undefined) | undefined;
84701
- /** Name of the system, as set in the Hayward OmniLogic app. */
84656
+ /** Name of the controller, as set in the Hayward OmniLogic app. */
84702
84657
  backyard_name?: (string | undefined) | undefined;
84703
- /** ID of the body of water within its system. Only present on a pool or spa body. */
84704
- body_of_water_id?: (string | undefined) | undefined;
84705
- /** Name of the body of water, as set in the Hayward OmniLogic app. Only present on a pool or spa body. */
84706
- body_of_water_name?: (string | undefined) | undefined;
84707
- /** ID of the virtual heater that carries the set point and heating request for the body of water. Only present on a pool or spa body. */
84708
- virtual_heater_id?: (string | undefined) | undefined;
84709
- /** Indicates whether the body of water shares its pump and heater with another body of water in the same system. */
84710
- is_shared_equipment?: (boolean | undefined) | undefined;
84711
- /** Priority of the body of water when it shares equipment. The `high` priority body, usually the spa, takes the shared heater when both request heat. */
84712
- shared_equipment_priority?: (('high' | 'low') | undefined) | undefined;
84658
+ /** ID of the pool or spa within its controller. Only present on a pool or spa. */
84659
+ system_id?: (string | undefined) | undefined;
84660
+ /** Name of the pool or spa, as set in the Hayward OmniLogic app. Only present on a pool or spa. */
84661
+ system_name?: (string | undefined) | undefined;
84713
84662
  } | undefined) | undefined;
84714
84663
  }) & ({
84715
84664
  /** Constraints on access codes for the device. Seam represents each constraint as an object with a `constraint_type` property. Depending on the constraint type, there may also be additional properties. Note that some constraints are manufacturer- or device-specific. */
@@ -84787,7 +84736,8 @@ export type Routes = {
84787
84736
  has_native_entry_events?: (boolean | undefined) | undefined;
84788
84737
  /** Indicates whether the lock is locked. */
84789
84738
  locked?: (boolean | undefined) | undefined;
84790
- /** Keypad battery status. */
84739
+ /** Keypad battery status.
84740
+ * @deprecated Use `accessory_keypad.battery` instead.*/
84791
84741
  keypad_battery?: ({
84792
84742
  /**
84793
84743
  Keypad battery charge level.
@@ -87608,16 +87558,16 @@ export type Routes = {
87608
87558
  result: null;
87609
87559
  /** Errors associated with the action attempt. Null for pending action attempts. */
87610
87560
  error: null;
87611
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
87612
- action_type: 'SET_POOL_HEATING';
87561
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
87562
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
87613
87563
  } | {
87614
87564
  /** ID of the action attempt. */
87615
87565
  action_attempt_id: string;
87616
87566
  status: 'success';
87617
87567
  /** Errors associated with the action attempt. Null for successful action attempts. */
87618
87568
  error: null;
87619
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
87620
- action_type: 'SET_POOL_HEATING';
87569
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
87570
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
87621
87571
  /** Result of the action. */
87622
87572
  result: {};
87623
87573
  } | {
@@ -87626,8 +87576,8 @@ export type Routes = {
87626
87576
  status: 'error';
87627
87577
  /** Result of the action attempt. Null for failed action attempts. */
87628
87578
  result: null;
87629
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
87630
- action_type: 'SET_POOL_HEATING';
87579
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
87580
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
87631
87581
  /** Error associated with the action. */
87632
87582
  error: {
87633
87583
  /** Type of the error. */
@@ -89863,16 +89813,16 @@ export type Routes = {
89863
89813
  result: null;
89864
89814
  /** Errors associated with the action attempt. Null for pending action attempts. */
89865
89815
  error: null;
89866
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
89867
- action_type: 'SET_POOL_HEATING';
89816
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
89817
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
89868
89818
  } | {
89869
89819
  /** ID of the action attempt. */
89870
89820
  action_attempt_id: string;
89871
89821
  status: 'success';
89872
89822
  /** Errors associated with the action attempt. Null for successful action attempts. */
89873
89823
  error: null;
89874
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
89875
- action_type: 'SET_POOL_HEATING';
89824
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
89825
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
89876
89826
  /** Result of the action. */
89877
89827
  result: {};
89878
89828
  } | {
@@ -89881,8 +89831,8 @@ export type Routes = {
89881
89831
  status: 'error';
89882
89832
  /** Result of the action attempt. Null for failed action attempts. */
89883
89833
  result: null;
89884
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
89885
- action_type: 'SET_POOL_HEATING';
89834
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
89835
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
89886
89836
  /** Error associated with the action. */
89887
89837
  error: {
89888
89838
  /** Type of the error. */
@@ -92174,16 +92124,16 @@ export type Routes = {
92174
92124
  result: null;
92175
92125
  /** Errors associated with the action attempt. Null for pending action attempts. */
92176
92126
  error: null;
92177
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
92178
- action_type: 'SET_POOL_HEATING';
92127
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
92128
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
92179
92129
  } | {
92180
92130
  /** ID of the action attempt. */
92181
92131
  action_attempt_id: string;
92182
92132
  status: 'success';
92183
92133
  /** Errors associated with the action attempt. Null for successful action attempts. */
92184
92134
  error: null;
92185
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
92186
- action_type: 'SET_POOL_HEATING';
92135
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
92136
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
92187
92137
  /** Result of the action. */
92188
92138
  result: {};
92189
92139
  } | {
@@ -92192,8 +92142,8 @@ export type Routes = {
92192
92142
  status: 'error';
92193
92143
  /** Result of the action attempt. Null for failed action attempts. */
92194
92144
  result: null;
92195
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
92196
- action_type: 'SET_POOL_HEATING';
92145
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
92146
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
92197
92147
  /** Error associated with the action. */
92198
92148
  error: {
92199
92149
  /** Type of the error. */
@@ -95729,16 +95679,16 @@ export type Routes = {
95729
95679
  result: null;
95730
95680
  /** Errors associated with the action attempt. Null for pending action attempts. */
95731
95681
  error: null;
95732
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
95733
- action_type: 'SET_POOL_HEATING';
95682
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
95683
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
95734
95684
  } | {
95735
95685
  /** ID of the action attempt. */
95736
95686
  action_attempt_id: string;
95737
95687
  status: 'success';
95738
95688
  /** Errors associated with the action attempt. Null for successful action attempts. */
95739
95689
  error: null;
95740
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
95741
- action_type: 'SET_POOL_HEATING';
95690
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
95691
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
95742
95692
  /** Result of the action. */
95743
95693
  result: {};
95744
95694
  } | {
@@ -95747,8 +95697,8 @@ export type Routes = {
95747
95697
  status: 'error';
95748
95698
  /** Result of the action attempt. Null for failed action attempts. */
95749
95699
  result: null;
95750
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
95751
- action_type: 'SET_POOL_HEATING';
95700
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
95701
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
95752
95702
  /** Error associated with the action. */
95753
95703
  error: {
95754
95704
  /** Type of the error. */
@@ -96038,9 +95988,9 @@ export type Routes = {
96038
95988
  /** ID of the Connect Webview for which you want to list devices. */
96039
95989
  connect_webview_id?: string | undefined;
96040
95990
  /** Device type by which you want to filter pool devices. */
96041
- device_type?: ('hayward_pool_system' | 'hayward_pool') | undefined;
95991
+ device_type?: ('hayward_pool_controller' | 'hayward_pool') | undefined;
96042
95992
  /** Array of device types by which you want to filter pool devices. */
96043
- device_types?: ('hayward_pool_system' | 'hayward_pool')[] | undefined;
95993
+ device_types?: ('hayward_pool_controller' | 'hayward_pool')[] | undefined;
96044
95994
  };
96045
95995
  formData: {};
96046
95996
  jsonResponse: {
@@ -96048,7 +95998,7 @@ export type Routes = {
96048
95998
  /** ID of the device. */
96049
95999
  device_id: string;
96050
96000
  /** Type of the device. The `august_lock` and `yale_lock` values are deprecated. Use `yale_access_lock` in place of `august_lock`, and `yale_access_lock` or `yale_home_lock` in place of `yale_lock`. */
96051
- device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_system' | 'hayward_pool');
96001
+ device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_controller' | 'hayward_pool');
96052
96002
  /** IDs of the spaces the device is in. */
96053
96003
  space_ids: string[];
96054
96004
  /** Optional nickname to describe the device, settable through Seam. */
@@ -96907,22 +96857,16 @@ export type Routes = {
96907
96857
  /** Models of the speakers bonded to this speaker, such as surrounds or a subwoofer. */
96908
96858
  bonded_member_models?: (string[] | undefined) | undefined;
96909
96859
  } | undefined) | undefined;
96910
- /** Metadata for a Hayward OmniLogic pool controller or body of water. */
96860
+ /** Metadata for a Hayward OmniLogic pool controller, pool, or spa. */
96911
96861
  hayward_omnilogic_metadata?: ({
96912
- /** ID of the Hayward OmniLogic system (the controller, called an MSP by Hayward) that the device belongs to. */
96862
+ /** ID of the Hayward OmniLogic controller that the device belongs to. */
96913
96863
  msp_system_id?: (string | undefined) | undefined;
96914
- /** Name of the system, as set in the Hayward OmniLogic app. */
96864
+ /** Name of the controller, as set in the Hayward OmniLogic app. */
96915
96865
  backyard_name?: (string | undefined) | undefined;
96916
- /** ID of the body of water within its system. Only present on a pool or spa body. */
96917
- body_of_water_id?: (string | undefined) | undefined;
96918
- /** Name of the body of water, as set in the Hayward OmniLogic app. Only present on a pool or spa body. */
96919
- body_of_water_name?: (string | undefined) | undefined;
96920
- /** ID of the virtual heater that carries the set point and heating request for the body of water. Only present on a pool or spa body. */
96921
- virtual_heater_id?: (string | undefined) | undefined;
96922
- /** Indicates whether the body of water shares its pump and heater with another body of water in the same system. */
96923
- is_shared_equipment?: (boolean | undefined) | undefined;
96924
- /** Priority of the body of water when it shares equipment. The `high` priority body, usually the spa, takes the shared heater when both request heat. */
96925
- shared_equipment_priority?: (('high' | 'low') | undefined) | undefined;
96866
+ /** ID of the pool or spa within its controller. Only present on a pool or spa. */
96867
+ system_id?: (string | undefined) | undefined;
96868
+ /** Name of the pool or spa, as set in the Hayward OmniLogic app. Only present on a pool or spa. */
96869
+ system_name?: (string | undefined) | undefined;
96926
96870
  } | undefined) | undefined;
96927
96871
  }) & ({
96928
96872
  /** Constraints on access codes for the device. Seam represents each constraint as an object with a `constraint_type` property. Depending on the constraint type, there may also be additional properties. Note that some constraints are manufacturer- or device-specific. */
@@ -97000,7 +96944,8 @@ export type Routes = {
97000
96944
  has_native_entry_events?: (boolean | undefined) | undefined;
97001
96945
  /** Indicates whether the lock is locked. */
97002
96946
  locked?: (boolean | undefined) | undefined;
97003
- /** Keypad battery status. */
96947
+ /** Keypad battery status.
96948
+ * @deprecated Use `accessory_keypad.battery` instead.*/
97004
96949
  keypad_battery?: ({
97005
96950
  /**
97006
96951
  Keypad battery charge level.
@@ -99811,16 +99756,16 @@ export type Routes = {
99811
99756
  result: null;
99812
99757
  /** Errors associated with the action attempt. Null for pending action attempts. */
99813
99758
  error: null;
99814
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
99815
- action_type: 'SET_POOL_HEATING';
99759
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
99760
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
99816
99761
  } | {
99817
99762
  /** ID of the action attempt. */
99818
99763
  action_attempt_id: string;
99819
99764
  status: 'success';
99820
99765
  /** Errors associated with the action attempt. Null for successful action attempts. */
99821
99766
  error: null;
99822
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
99823
- action_type: 'SET_POOL_HEATING';
99767
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
99768
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
99824
99769
  /** Result of the action. */
99825
99770
  result: {};
99826
99771
  } | {
@@ -99829,8 +99774,8 @@ export type Routes = {
99829
99774
  status: 'error';
99830
99775
  /** Result of the action attempt. Null for failed action attempts. */
99831
99776
  result: null;
99832
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
99833
- action_type: 'SET_POOL_HEATING';
99777
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
99778
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
99834
99779
  /** Error associated with the action. */
99835
99780
  error: {
99836
99781
  /** Type of the error. */
@@ -104598,16 +104543,16 @@ export type Routes = {
104598
104543
  result: null;
104599
104544
  /** Errors associated with the action attempt. Null for pending action attempts. */
104600
104545
  error: null;
104601
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
104602
- action_type: 'SET_POOL_HEATING';
104546
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
104547
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
104603
104548
  } | {
104604
104549
  /** ID of the action attempt. */
104605
104550
  action_attempt_id: string;
104606
104551
  status: 'success';
104607
104552
  /** Errors associated with the action attempt. Null for successful action attempts. */
104608
104553
  error: null;
104609
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
104610
- action_type: 'SET_POOL_HEATING';
104554
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
104555
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
104611
104556
  /** Result of the action. */
104612
104557
  result: {};
104613
104558
  } | {
@@ -104616,8 +104561,8 @@ export type Routes = {
104616
104561
  status: 'error';
104617
104562
  /** Result of the action attempt. Null for failed action attempts. */
104618
104563
  result: null;
104619
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
104620
- action_type: 'SET_POOL_HEATING';
104564
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
104565
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
104621
104566
  /** Error associated with the action. */
104622
104567
  error: {
104623
104568
  /** Type of the error. */
@@ -116052,7 +115997,7 @@ export type Routes = {
116052
115997
  /** ID of the device. */
116053
115998
  device_id: string;
116054
115999
  /** Type of the device. The `august_lock` and `yale_lock` values are deprecated. Use `yale_access_lock` in place of `august_lock`, and `yale_access_lock` or `yale_home_lock` in place of `yale_lock`. */
116055
- device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_system' | 'hayward_pool');
116000
+ device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_controller' | 'hayward_pool');
116056
116001
  /** IDs of the spaces the device is in. */
116057
116002
  space_ids: string[];
116058
116003
  /** Optional nickname to describe the device, settable through Seam. */
@@ -116911,22 +116856,16 @@ export type Routes = {
116911
116856
  /** Models of the speakers bonded to this speaker, such as surrounds or a subwoofer. */
116912
116857
  bonded_member_models?: (string[] | undefined) | undefined;
116913
116858
  } | undefined) | undefined;
116914
- /** Metadata for a Hayward OmniLogic pool controller or body of water. */
116859
+ /** Metadata for a Hayward OmniLogic pool controller, pool, or spa. */
116915
116860
  hayward_omnilogic_metadata?: ({
116916
- /** ID of the Hayward OmniLogic system (the controller, called an MSP by Hayward) that the device belongs to. */
116861
+ /** ID of the Hayward OmniLogic controller that the device belongs to. */
116917
116862
  msp_system_id?: (string | undefined) | undefined;
116918
- /** Name of the system, as set in the Hayward OmniLogic app. */
116863
+ /** Name of the controller, as set in the Hayward OmniLogic app. */
116919
116864
  backyard_name?: (string | undefined) | undefined;
116920
- /** ID of the body of water within its system. Only present on a pool or spa body. */
116921
- body_of_water_id?: (string | undefined) | undefined;
116922
- /** Name of the body of water, as set in the Hayward OmniLogic app. Only present on a pool or spa body. */
116923
- body_of_water_name?: (string | undefined) | undefined;
116924
- /** ID of the virtual heater that carries the set point and heating request for the body of water. Only present on a pool or spa body. */
116925
- virtual_heater_id?: (string | undefined) | undefined;
116926
- /** Indicates whether the body of water shares its pump and heater with another body of water in the same system. */
116927
- is_shared_equipment?: (boolean | undefined) | undefined;
116928
- /** Priority of the body of water when it shares equipment. The `high` priority body, usually the spa, takes the shared heater when both request heat. */
116929
- shared_equipment_priority?: (('high' | 'low') | undefined) | undefined;
116865
+ /** ID of the pool or spa within its controller. Only present on a pool or spa. */
116866
+ system_id?: (string | undefined) | undefined;
116867
+ /** Name of the pool or spa, as set in the Hayward OmniLogic app. Only present on a pool or spa. */
116868
+ system_name?: (string | undefined) | undefined;
116930
116869
  } | undefined) | undefined;
116931
116870
  }) & ({
116932
116871
  /** Constraints on access codes for the device. Seam represents each constraint as an object with a `constraint_type` property. Depending on the constraint type, there may also be additional properties. Note that some constraints are manufacturer- or device-specific. */
@@ -117004,7 +116943,8 @@ export type Routes = {
117004
116943
  has_native_entry_events?: (boolean | undefined) | undefined;
117005
116944
  /** Indicates whether the lock is locked. */
117006
116945
  locked?: (boolean | undefined) | undefined;
117007
- /** Keypad battery status. */
116946
+ /** Keypad battery status.
116947
+ * @deprecated Use `accessory_keypad.battery` instead.*/
117008
116948
  keypad_battery?: ({
117009
116949
  /**
117010
116950
  Keypad battery charge level.
@@ -120817,16 +120757,16 @@ export type Routes = {
120817
120757
  result: null;
120818
120758
  /** Errors associated with the action attempt. Null for pending action attempts. */
120819
120759
  error: null;
120820
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
120821
- action_type: 'SET_POOL_HEATING';
120760
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
120761
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
120822
120762
  } | {
120823
120763
  /** ID of the action attempt. */
120824
120764
  action_attempt_id: string;
120825
120765
  status: 'success';
120826
120766
  /** Errors associated with the action attempt. Null for successful action attempts. */
120827
120767
  error: null;
120828
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
120829
- action_type: 'SET_POOL_HEATING';
120768
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
120769
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
120830
120770
  /** Result of the action. */
120831
120771
  result: {};
120832
120772
  } | {
@@ -120835,8 +120775,8 @@ export type Routes = {
120835
120775
  status: 'error';
120836
120776
  /** Result of the action attempt. Null for failed action attempts. */
120837
120777
  result: null;
120838
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
120839
- action_type: 'SET_POOL_HEATING';
120778
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
120779
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
120840
120780
  /** Error associated with the action. */
120841
120781
  error: {
120842
120782
  /** Type of the error. */
@@ -123053,16 +122993,16 @@ export type Routes = {
123053
122993
  result: null;
123054
122994
  /** Errors associated with the action attempt. Null for pending action attempts. */
123055
122995
  error: null;
123056
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
123057
- action_type: 'SET_POOL_HEATING';
122996
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
122997
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
123058
122998
  } | {
123059
122999
  /** ID of the action attempt. */
123060
123000
  action_attempt_id: string;
123061
123001
  status: 'success';
123062
123002
  /** Errors associated with the action attempt. Null for successful action attempts. */
123063
123003
  error: null;
123064
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
123065
- action_type: 'SET_POOL_HEATING';
123004
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
123005
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
123066
123006
  /** Result of the action. */
123067
123007
  result: {};
123068
123008
  } | {
@@ -123071,8 +123011,8 @@ export type Routes = {
123071
123011
  status: 'error';
123072
123012
  /** Result of the action attempt. Null for failed action attempts. */
123073
123013
  result: null;
123074
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
123075
- action_type: 'SET_POOL_HEATING';
123014
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
123015
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
123076
123016
  /** Error associated with the action. */
123077
123017
  error: {
123078
123018
  /** Type of the error. */
@@ -125293,16 +125233,16 @@ export type Routes = {
125293
125233
  result: null;
125294
125234
  /** Errors associated with the action attempt. Null for pending action attempts. */
125295
125235
  error: null;
125296
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
125297
- action_type: 'SET_POOL_HEATING';
125236
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
125237
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
125298
125238
  } | {
125299
125239
  /** ID of the action attempt. */
125300
125240
  action_attempt_id: string;
125301
125241
  status: 'success';
125302
125242
  /** Errors associated with the action attempt. Null for successful action attempts. */
125303
125243
  error: null;
125304
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
125305
- action_type: 'SET_POOL_HEATING';
125244
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
125245
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
125306
125246
  /** Result of the action. */
125307
125247
  result: {};
125308
125248
  } | {
@@ -125311,8 +125251,8 @@ export type Routes = {
125311
125251
  status: 'error';
125312
125252
  /** Result of the action attempt. Null for failed action attempts. */
125313
125253
  result: null;
125314
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
125315
- action_type: 'SET_POOL_HEATING';
125254
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
125255
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
125316
125256
  /** Error associated with the action. */
125317
125257
  error: {
125318
125258
  /** Type of the error. */
@@ -127531,16 +127471,16 @@ export type Routes = {
127531
127471
  result: null;
127532
127472
  /** Errors associated with the action attempt. Null for pending action attempts. */
127533
127473
  error: null;
127534
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
127535
- action_type: 'SET_POOL_HEATING';
127474
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
127475
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
127536
127476
  } | {
127537
127477
  /** ID of the action attempt. */
127538
127478
  action_attempt_id: string;
127539
127479
  status: 'success';
127540
127480
  /** Errors associated with the action attempt. Null for successful action attempts. */
127541
127481
  error: null;
127542
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
127543
- action_type: 'SET_POOL_HEATING';
127482
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
127483
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
127544
127484
  /** Result of the action. */
127545
127485
  result: {};
127546
127486
  } | {
@@ -127549,8 +127489,8 @@ export type Routes = {
127549
127489
  status: 'error';
127550
127490
  /** Result of the action attempt. Null for failed action attempts. */
127551
127491
  result: null;
127552
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
127553
- action_type: 'SET_POOL_HEATING';
127492
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
127493
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
127554
127494
  /** Error associated with the action. */
127555
127495
  error: {
127556
127496
  /** Type of the error. */
@@ -129771,16 +129711,16 @@ export type Routes = {
129771
129711
  result: null;
129772
129712
  /** Errors associated with the action attempt. Null for pending action attempts. */
129773
129713
  error: null;
129774
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
129775
- action_type: 'SET_POOL_HEATING';
129714
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
129715
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
129776
129716
  } | {
129777
129717
  /** ID of the action attempt. */
129778
129718
  action_attempt_id: string;
129779
129719
  status: 'success';
129780
129720
  /** Errors associated with the action attempt. Null for successful action attempts. */
129781
129721
  error: null;
129782
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
129783
- action_type: 'SET_POOL_HEATING';
129722
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
129723
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
129784
129724
  /** Result of the action. */
129785
129725
  result: {};
129786
129726
  } | {
@@ -129789,8 +129729,8 @@ export type Routes = {
129789
129729
  status: 'error';
129790
129730
  /** Result of the action attempt. Null for failed action attempts. */
129791
129731
  result: null;
129792
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
129793
- action_type: 'SET_POOL_HEATING';
129732
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
129733
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
129794
129734
  /** Error associated with the action. */
129795
129735
  error: {
129796
129736
  /** Type of the error. */
@@ -132007,16 +131947,16 @@ export type Routes = {
132007
131947
  result: null;
132008
131948
  /** Errors associated with the action attempt. Null for pending action attempts. */
132009
131949
  error: null;
132010
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
132011
- action_type: 'SET_POOL_HEATING';
131950
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
131951
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
132012
131952
  } | {
132013
131953
  /** ID of the action attempt. */
132014
131954
  action_attempt_id: string;
132015
131955
  status: 'success';
132016
131956
  /** Errors associated with the action attempt. Null for successful action attempts. */
132017
131957
  error: null;
132018
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
132019
- action_type: 'SET_POOL_HEATING';
131958
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
131959
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
132020
131960
  /** Result of the action. */
132021
131961
  result: {};
132022
131962
  } | {
@@ -132025,8 +131965,8 @@ export type Routes = {
132025
131965
  status: 'error';
132026
131966
  /** Result of the action attempt. Null for failed action attempts. */
132027
131967
  result: null;
132028
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
132029
- action_type: 'SET_POOL_HEATING';
131968
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
131969
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
132030
131970
  /** Error associated with the action. */
132031
131971
  error: {
132032
131972
  /** Type of the error. */
@@ -134245,16 +134185,16 @@ export type Routes = {
134245
134185
  result: null;
134246
134186
  /** Errors associated with the action attempt. Null for pending action attempts. */
134247
134187
  error: null;
134248
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
134249
- action_type: 'SET_POOL_HEATING';
134188
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
134189
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
134250
134190
  } | {
134251
134191
  /** ID of the action attempt. */
134252
134192
  action_attempt_id: string;
134253
134193
  status: 'success';
134254
134194
  /** Errors associated with the action attempt. Null for successful action attempts. */
134255
134195
  error: null;
134256
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
134257
- action_type: 'SET_POOL_HEATING';
134196
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
134197
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
134258
134198
  /** Result of the action. */
134259
134199
  result: {};
134260
134200
  } | {
@@ -134263,8 +134203,8 @@ export type Routes = {
134263
134203
  status: 'error';
134264
134204
  /** Result of the action attempt. Null for failed action attempts. */
134265
134205
  result: null;
134266
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
134267
- action_type: 'SET_POOL_HEATING';
134206
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
134207
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
134268
134208
  /** Error associated with the action. */
134269
134209
  error: {
134270
134210
  /** Type of the error. */
@@ -136481,16 +136421,16 @@ export type Routes = {
136481
136421
  result: null;
136482
136422
  /** Errors associated with the action attempt. Null for pending action attempts. */
136483
136423
  error: null;
136484
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
136485
- action_type: 'SET_POOL_HEATING';
136424
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
136425
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
136486
136426
  } | {
136487
136427
  /** ID of the action attempt. */
136488
136428
  action_attempt_id: string;
136489
136429
  status: 'success';
136490
136430
  /** Errors associated with the action attempt. Null for successful action attempts. */
136491
136431
  error: null;
136492
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
136493
- action_type: 'SET_POOL_HEATING';
136432
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
136433
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
136494
136434
  /** Result of the action. */
136495
136435
  result: {};
136496
136436
  } | {
@@ -136499,8 +136439,8 @@ export type Routes = {
136499
136439
  status: 'error';
136500
136440
  /** Result of the action attempt. Null for failed action attempts. */
136501
136441
  result: null;
136502
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
136503
- action_type: 'SET_POOL_HEATING';
136442
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
136443
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
136504
136444
  /** Error associated with the action. */
136505
136445
  error: {
136506
136446
  /** Type of the error. */
@@ -138719,16 +138659,16 @@ export type Routes = {
138719
138659
  result: null;
138720
138660
  /** Errors associated with the action attempt. Null for pending action attempts. */
138721
138661
  error: null;
138722
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
138723
- action_type: 'SET_POOL_HEATING';
138662
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
138663
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
138724
138664
  } | {
138725
138665
  /** ID of the action attempt. */
138726
138666
  action_attempt_id: string;
138727
138667
  status: 'success';
138728
138668
  /** Errors associated with the action attempt. Null for successful action attempts. */
138729
138669
  error: null;
138730
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
138731
- action_type: 'SET_POOL_HEATING';
138670
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
138671
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
138732
138672
  /** Result of the action. */
138733
138673
  result: {};
138734
138674
  } | {
@@ -138737,8 +138677,8 @@ export type Routes = {
138737
138677
  status: 'error';
138738
138678
  /** Result of the action attempt. Null for failed action attempts. */
138739
138679
  result: null;
138740
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
138741
- action_type: 'SET_POOL_HEATING';
138680
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
138681
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
138742
138682
  /** Error associated with the action. */
138743
138683
  error: {
138744
138684
  /** Type of the error. */
@@ -140955,16 +140895,16 @@ export type Routes = {
140955
140895
  result: null;
140956
140896
  /** Errors associated with the action attempt. Null for pending action attempts. */
140957
140897
  error: null;
140958
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
140959
- action_type: 'SET_POOL_HEATING';
140898
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
140899
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
140960
140900
  } | {
140961
140901
  /** ID of the action attempt. */
140962
140902
  action_attempt_id: string;
140963
140903
  status: 'success';
140964
140904
  /** Errors associated with the action attempt. Null for successful action attempts. */
140965
140905
  error: null;
140966
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
140967
- action_type: 'SET_POOL_HEATING';
140906
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
140907
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
140968
140908
  /** Result of the action. */
140969
140909
  result: {};
140970
140910
  } | {
@@ -140973,8 +140913,8 @@ export type Routes = {
140973
140913
  status: 'error';
140974
140914
  /** Result of the action attempt. Null for failed action attempts. */
140975
140915
  result: null;
140976
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
140977
- action_type: 'SET_POOL_HEATING';
140916
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
140917
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
140978
140918
  /** Error associated with the action. */
140979
140919
  error: {
140980
140920
  /** Type of the error. */
@@ -143195,16 +143135,16 @@ export type Routes = {
143195
143135
  result: null;
143196
143136
  /** Errors associated with the action attempt. Null for pending action attempts. */
143197
143137
  error: null;
143198
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
143199
- action_type: 'SET_POOL_HEATING';
143138
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
143139
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
143200
143140
  } | {
143201
143141
  /** ID of the action attempt. */
143202
143142
  action_attempt_id: string;
143203
143143
  status: 'success';
143204
143144
  /** Errors associated with the action attempt. Null for successful action attempts. */
143205
143145
  error: null;
143206
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
143207
- action_type: 'SET_POOL_HEATING';
143146
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
143147
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
143208
143148
  /** Result of the action. */
143209
143149
  result: {};
143210
143150
  } | {
@@ -143213,8 +143153,8 @@ export type Routes = {
143213
143153
  status: 'error';
143214
143154
  /** Result of the action attempt. Null for failed action attempts. */
143215
143155
  result: null;
143216
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
143217
- action_type: 'SET_POOL_HEATING';
143156
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
143157
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
143218
143158
  /** Error associated with the action. */
143219
143159
  error: {
143220
143160
  /** Type of the error. */
@@ -145543,16 +145483,16 @@ export type Routes = {
145543
145483
  result: null;
145544
145484
  /** Errors associated with the action attempt. Null for pending action attempts. */
145545
145485
  error: null;
145546
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
145547
- action_type: 'SET_POOL_HEATING';
145486
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
145487
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
145548
145488
  } | {
145549
145489
  /** ID of the action attempt. */
145550
145490
  action_attempt_id: string;
145551
145491
  status: 'success';
145552
145492
  /** Errors associated with the action attempt. Null for successful action attempts. */
145553
145493
  error: null;
145554
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
145555
- action_type: 'SET_POOL_HEATING';
145494
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
145495
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
145556
145496
  /** Result of the action. */
145557
145497
  result: {};
145558
145498
  } | {
@@ -145561,8 +145501,8 @@ export type Routes = {
145561
145501
  status: 'error';
145562
145502
  /** Result of the action attempt. Null for failed action attempts. */
145563
145503
  result: null;
145564
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
145565
- action_type: 'SET_POOL_HEATING';
145504
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
145505
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
145566
145506
  /** Error associated with the action. */
145567
145507
  error: {
145568
145508
  /** Type of the error. */
@@ -145872,7 +145812,7 @@ export type Routes = {
145872
145812
  /** ID of the device. */
145873
145813
  device_id: string;
145874
145814
  /** Type of the device. The `august_lock` and `yale_lock` values are deprecated. Use `yale_access_lock` in place of `august_lock`, and `yale_access_lock` or `yale_home_lock` in place of `yale_lock`. */
145875
- device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_system' | 'hayward_pool');
145815
+ device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_controller' | 'hayward_pool');
145876
145816
  /** IDs of the spaces the device is in. */
145877
145817
  space_ids: string[];
145878
145818
  /** Optional nickname to describe the device, settable through Seam. */
@@ -146731,22 +146671,16 @@ export type Routes = {
146731
146671
  /** Models of the speakers bonded to this speaker, such as surrounds or a subwoofer. */
146732
146672
  bonded_member_models?: (string[] | undefined) | undefined;
146733
146673
  } | undefined) | undefined;
146734
- /** Metadata for a Hayward OmniLogic pool controller or body of water. */
146674
+ /** Metadata for a Hayward OmniLogic pool controller, pool, or spa. */
146735
146675
  hayward_omnilogic_metadata?: ({
146736
- /** ID of the Hayward OmniLogic system (the controller, called an MSP by Hayward) that the device belongs to. */
146676
+ /** ID of the Hayward OmniLogic controller that the device belongs to. */
146737
146677
  msp_system_id?: (string | undefined) | undefined;
146738
- /** Name of the system, as set in the Hayward OmniLogic app. */
146678
+ /** Name of the controller, as set in the Hayward OmniLogic app. */
146739
146679
  backyard_name?: (string | undefined) | undefined;
146740
- /** ID of the body of water within its system. Only present on a pool or spa body. */
146741
- body_of_water_id?: (string | undefined) | undefined;
146742
- /** Name of the body of water, as set in the Hayward OmniLogic app. Only present on a pool or spa body. */
146743
- body_of_water_name?: (string | undefined) | undefined;
146744
- /** ID of the virtual heater that carries the set point and heating request for the body of water. Only present on a pool or spa body. */
146745
- virtual_heater_id?: (string | undefined) | undefined;
146746
- /** Indicates whether the body of water shares its pump and heater with another body of water in the same system. */
146747
- is_shared_equipment?: (boolean | undefined) | undefined;
146748
- /** Priority of the body of water when it shares equipment. The `high` priority body, usually the spa, takes the shared heater when both request heat. */
146749
- shared_equipment_priority?: (('high' | 'low') | undefined) | undefined;
146680
+ /** ID of the pool or spa within its controller. Only present on a pool or spa. */
146681
+ system_id?: (string | undefined) | undefined;
146682
+ /** Name of the pool or spa, as set in the Hayward OmniLogic app. Only present on a pool or spa. */
146683
+ system_name?: (string | undefined) | undefined;
146750
146684
  } | undefined) | undefined;
146751
146685
  }) & ({
146752
146686
  /** Constraints on access codes for the device. Seam represents each constraint as an object with a `constraint_type` property. Depending on the constraint type, there may also be additional properties. Note that some constraints are manufacturer- or device-specific. */
@@ -146824,7 +146758,8 @@ export type Routes = {
146824
146758
  has_native_entry_events?: (boolean | undefined) | undefined;
146825
146759
  /** Indicates whether the lock is locked. */
146826
146760
  locked?: (boolean | undefined) | undefined;
146827
- /** Keypad battery status. */
146761
+ /** Keypad battery status.
146762
+ * @deprecated Use `accessory_keypad.battery` instead.*/
146828
146763
  keypad_battery?: ({
146829
146764
  /**
146830
146765
  Keypad battery charge level.
@@ -149639,16 +149574,16 @@ export type Routes = {
149639
149574
  result: null;
149640
149575
  /** Errors associated with the action attempt. Null for pending action attempts. */
149641
149576
  error: null;
149642
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
149643
- action_type: 'SET_POOL_HEATING';
149577
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
149578
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
149644
149579
  } | {
149645
149580
  /** ID of the action attempt. */
149646
149581
  action_attempt_id: string;
149647
149582
  status: 'success';
149648
149583
  /** Errors associated with the action attempt. Null for successful action attempts. */
149649
149584
  error: null;
149650
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
149651
- action_type: 'SET_POOL_HEATING';
149585
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
149586
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
149652
149587
  /** Result of the action. */
149653
149588
  result: {};
149654
149589
  } | {
@@ -149657,8 +149592,8 @@ export type Routes = {
149657
149592
  status: 'error';
149658
149593
  /** Result of the action attempt. Null for failed action attempts. */
149659
149594
  result: null;
149660
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
149661
- action_type: 'SET_POOL_HEATING';
149595
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
149596
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
149662
149597
  /** Error associated with the action. */
149663
149598
  error: {
149664
149599
  /** Type of the error. */
@@ -151883,16 +151818,16 @@ export type Routes = {
151883
151818
  result: null;
151884
151819
  /** Errors associated with the action attempt. Null for pending action attempts. */
151885
151820
  error: null;
151886
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
151887
- action_type: 'SET_POOL_HEATING';
151821
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
151822
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
151888
151823
  } | {
151889
151824
  /** ID of the action attempt. */
151890
151825
  action_attempt_id: string;
151891
151826
  status: 'success';
151892
151827
  /** Errors associated with the action attempt. Null for successful action attempts. */
151893
151828
  error: null;
151894
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
151895
- action_type: 'SET_POOL_HEATING';
151829
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
151830
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
151896
151831
  /** Result of the action. */
151897
151832
  result: {};
151898
151833
  } | {
@@ -151901,8 +151836,8 @@ export type Routes = {
151901
151836
  status: 'error';
151902
151837
  /** Result of the action attempt. Null for failed action attempts. */
151903
151838
  result: null;
151904
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
151905
- action_type: 'SET_POOL_HEATING';
151839
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
151840
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
151906
151841
  /** Error associated with the action. */
151907
151842
  error: {
151908
151843
  /** Type of the error. */
@@ -152204,7 +152139,7 @@ export type Routes = {
152204
152139
  /** ID of the device. */
152205
152140
  device_id: string;
152206
152141
  /** Type of the device. The `august_lock` and `yale_lock` values are deprecated. Use `yale_access_lock` in place of `august_lock`, and `yale_access_lock` or `yale_home_lock` in place of `yale_lock`. */
152207
- device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_system' | 'hayward_pool');
152142
+ device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_controller' | 'hayward_pool');
152208
152143
  /** IDs of the spaces the device is in. */
152209
152144
  space_ids: string[];
152210
152145
  /** Optional nickname to describe the device, settable through Seam. */
@@ -153063,22 +152998,16 @@ export type Routes = {
153063
152998
  /** Models of the speakers bonded to this speaker, such as surrounds or a subwoofer. */
153064
152999
  bonded_member_models?: (string[] | undefined) | undefined;
153065
153000
  } | undefined) | undefined;
153066
- /** Metadata for a Hayward OmniLogic pool controller or body of water. */
153001
+ /** Metadata for a Hayward OmniLogic pool controller, pool, or spa. */
153067
153002
  hayward_omnilogic_metadata?: ({
153068
- /** ID of the Hayward OmniLogic system (the controller, called an MSP by Hayward) that the device belongs to. */
153003
+ /** ID of the Hayward OmniLogic controller that the device belongs to. */
153069
153004
  msp_system_id?: (string | undefined) | undefined;
153070
- /** Name of the system, as set in the Hayward OmniLogic app. */
153005
+ /** Name of the controller, as set in the Hayward OmniLogic app. */
153071
153006
  backyard_name?: (string | undefined) | undefined;
153072
- /** ID of the body of water within its system. Only present on a pool or spa body. */
153073
- body_of_water_id?: (string | undefined) | undefined;
153074
- /** Name of the body of water, as set in the Hayward OmniLogic app. Only present on a pool or spa body. */
153075
- body_of_water_name?: (string | undefined) | undefined;
153076
- /** ID of the virtual heater that carries the set point and heating request for the body of water. Only present on a pool or spa body. */
153077
- virtual_heater_id?: (string | undefined) | undefined;
153078
- /** Indicates whether the body of water shares its pump and heater with another body of water in the same system. */
153079
- is_shared_equipment?: (boolean | undefined) | undefined;
153080
- /** Priority of the body of water when it shares equipment. The `high` priority body, usually the spa, takes the shared heater when both request heat. */
153081
- shared_equipment_priority?: (('high' | 'low') | undefined) | undefined;
153007
+ /** ID of the pool or spa within its controller. Only present on a pool or spa. */
153008
+ system_id?: (string | undefined) | undefined;
153009
+ /** Name of the pool or spa, as set in the Hayward OmniLogic app. Only present on a pool or spa. */
153010
+ system_name?: (string | undefined) | undefined;
153082
153011
  } | undefined) | undefined;
153083
153012
  }) & ({
153084
153013
  /** Constraints on access codes for the device. Seam represents each constraint as an object with a `constraint_type` property. Depending on the constraint type, there may also be additional properties. Note that some constraints are manufacturer- or device-specific. */
@@ -153156,7 +153085,8 @@ export type Routes = {
153156
153085
  has_native_entry_events?: (boolean | undefined) | undefined;
153157
153086
  /** Indicates whether the lock is locked. */
153158
153087
  locked?: (boolean | undefined) | undefined;
153159
- /** Keypad battery status. */
153088
+ /** Keypad battery status.
153089
+ * @deprecated Use `accessory_keypad.battery` instead.*/
153160
153090
  keypad_battery?: ({
153161
153091
  /**
153162
153092
  Keypad battery charge level.
@@ -154028,7 +153958,7 @@ export type Routes = {
154028
153958
  /** ID of the device. */
154029
153959
  device_id: string;
154030
153960
  /** Type of the device. The `august_lock` and `yale_lock` values are deprecated. Use `yale_access_lock` in place of `august_lock`, and `yale_access_lock` or `yale_home_lock` in place of `yale_lock`. */
154031
- device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_system' | 'hayward_pool');
153961
+ device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_controller' | 'hayward_pool');
154032
153962
  /** IDs of the spaces the device is in. */
154033
153963
  space_ids: string[];
154034
153964
  /** Optional nickname to describe the device, settable through Seam. */
@@ -154887,22 +154817,16 @@ export type Routes = {
154887
154817
  /** Models of the speakers bonded to this speaker, such as surrounds or a subwoofer. */
154888
154818
  bonded_member_models?: (string[] | undefined) | undefined;
154889
154819
  } | undefined) | undefined;
154890
- /** Metadata for a Hayward OmniLogic pool controller or body of water. */
154820
+ /** Metadata for a Hayward OmniLogic pool controller, pool, or spa. */
154891
154821
  hayward_omnilogic_metadata?: ({
154892
- /** ID of the Hayward OmniLogic system (the controller, called an MSP by Hayward) that the device belongs to. */
154822
+ /** ID of the Hayward OmniLogic controller that the device belongs to. */
154893
154823
  msp_system_id?: (string | undefined) | undefined;
154894
- /** Name of the system, as set in the Hayward OmniLogic app. */
154824
+ /** Name of the controller, as set in the Hayward OmniLogic app. */
154895
154825
  backyard_name?: (string | undefined) | undefined;
154896
- /** ID of the body of water within its system. Only present on a pool or spa body. */
154897
- body_of_water_id?: (string | undefined) | undefined;
154898
- /** Name of the body of water, as set in the Hayward OmniLogic app. Only present on a pool or spa body. */
154899
- body_of_water_name?: (string | undefined) | undefined;
154900
- /** ID of the virtual heater that carries the set point and heating request for the body of water. Only present on a pool or spa body. */
154901
- virtual_heater_id?: (string | undefined) | undefined;
154902
- /** Indicates whether the body of water shares its pump and heater with another body of water in the same system. */
154903
- is_shared_equipment?: (boolean | undefined) | undefined;
154904
- /** Priority of the body of water when it shares equipment. The `high` priority body, usually the spa, takes the shared heater when both request heat. */
154905
- shared_equipment_priority?: (('high' | 'low') | undefined) | undefined;
154826
+ /** ID of the pool or spa within its controller. Only present on a pool or spa. */
154827
+ system_id?: (string | undefined) | undefined;
154828
+ /** Name of the pool or spa, as set in the Hayward OmniLogic app. Only present on a pool or spa. */
154829
+ system_name?: (string | undefined) | undefined;
154906
154830
  } | undefined) | undefined;
154907
154831
  }) & ({
154908
154832
  /** Constraints on access codes for the device. Seam represents each constraint as an object with a `constraint_type` property. Depending on the constraint type, there may also be additional properties. Note that some constraints are manufacturer- or device-specific. */
@@ -154980,7 +154904,8 @@ export type Routes = {
154980
154904
  has_native_entry_events?: (boolean | undefined) | undefined;
154981
154905
  /** Indicates whether the lock is locked. */
154982
154906
  locked?: (boolean | undefined) | undefined;
154983
- /** Keypad battery status. */
154907
+ /** Keypad battery status.
154908
+ * @deprecated Use `accessory_keypad.battery` instead.*/
154984
154909
  keypad_battery?: ({
154985
154910
  /**
154986
154911
  Keypad battery charge level.
@@ -157791,16 +157716,16 @@ export type Routes = {
157791
157716
  result: null;
157792
157717
  /** Errors associated with the action attempt. Null for pending action attempts. */
157793
157718
  error: null;
157794
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
157795
- action_type: 'SET_POOL_HEATING';
157719
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
157720
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
157796
157721
  } | {
157797
157722
  /** ID of the action attempt. */
157798
157723
  action_attempt_id: string;
157799
157724
  status: 'success';
157800
157725
  /** Errors associated with the action attempt. Null for successful action attempts. */
157801
157726
  error: null;
157802
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
157803
- action_type: 'SET_POOL_HEATING';
157727
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
157728
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
157804
157729
  /** Result of the action. */
157805
157730
  result: {};
157806
157731
  } | {
@@ -157809,8 +157734,8 @@ export type Routes = {
157809
157734
  status: 'error';
157810
157735
  /** Result of the action attempt. Null for failed action attempts. */
157811
157736
  result: null;
157812
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
157813
- action_type: 'SET_POOL_HEATING';
157737
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
157738
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
157814
157739
  /** Error associated with the action. */
157815
157740
  error: {
157816
157741
  /** Type of the error. */
@@ -160236,16 +160161,16 @@ export type Routes = {
160236
160161
  result: null;
160237
160162
  /** Errors associated with the action attempt. Null for pending action attempts. */
160238
160163
  error: null;
160239
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
160240
- action_type: 'SET_POOL_HEATING';
160164
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
160165
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
160241
160166
  } | {
160242
160167
  /** ID of the action attempt. */
160243
160168
  action_attempt_id: string;
160244
160169
  status: 'success';
160245
160170
  /** Errors associated with the action attempt. Null for successful action attempts. */
160246
160171
  error: null;
160247
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
160248
- action_type: 'SET_POOL_HEATING';
160172
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
160173
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
160249
160174
  /** Result of the action. */
160250
160175
  result: {};
160251
160176
  } | {
@@ -160254,8 +160179,8 @@ export type Routes = {
160254
160179
  status: 'error';
160255
160180
  /** Result of the action attempt. Null for failed action attempts. */
160256
160181
  result: null;
160257
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
160258
- action_type: 'SET_POOL_HEATING';
160182
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
160183
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
160259
160184
  /** Error associated with the action. */
160260
160185
  error: {
160261
160186
  /** Type of the error. */
@@ -162505,16 +162430,16 @@ export type Routes = {
162505
162430
  result: null;
162506
162431
  /** Errors associated with the action attempt. Null for pending action attempts. */
162507
162432
  error: null;
162508
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
162509
- action_type: 'SET_POOL_HEATING';
162433
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
162434
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
162510
162435
  } | {
162511
162436
  /** ID of the action attempt. */
162512
162437
  action_attempt_id: string;
162513
162438
  status: 'success';
162514
162439
  /** Errors associated with the action attempt. Null for successful action attempts. */
162515
162440
  error: null;
162516
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
162517
- action_type: 'SET_POOL_HEATING';
162441
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
162442
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
162518
162443
  /** Result of the action. */
162519
162444
  result: {};
162520
162445
  } | {
@@ -162523,8 +162448,8 @@ export type Routes = {
162523
162448
  status: 'error';
162524
162449
  /** Result of the action attempt. Null for failed action attempts. */
162525
162450
  result: null;
162526
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
162527
- action_type: 'SET_POOL_HEATING';
162451
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
162452
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
162528
162453
  /** Error associated with the action. */
162529
162454
  error: {
162530
162455
  /** Type of the error. */
@@ -164886,16 +164811,16 @@ export type Routes = {
164886
164811
  result: null;
164887
164812
  /** Errors associated with the action attempt. Null for pending action attempts. */
164888
164813
  error: null;
164889
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
164890
- action_type: 'SET_POOL_HEATING';
164814
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
164815
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
164891
164816
  } | {
164892
164817
  /** ID of the action attempt. */
164893
164818
  action_attempt_id: string;
164894
164819
  status: 'success';
164895
164820
  /** Errors associated with the action attempt. Null for successful action attempts. */
164896
164821
  error: null;
164897
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
164898
- action_type: 'SET_POOL_HEATING';
164822
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
164823
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
164899
164824
  /** Result of the action. */
164900
164825
  result: {};
164901
164826
  } | {
@@ -164904,8 +164829,8 @@ export type Routes = {
164904
164829
  status: 'error';
164905
164830
  /** Result of the action attempt. Null for failed action attempts. */
164906
164831
  result: null;
164907
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
164908
- action_type: 'SET_POOL_HEATING';
164832
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
164833
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
164909
164834
  /** Error associated with the action. */
164910
164835
  error: {
164911
164836
  /** Type of the error. */
@@ -165933,7 +165858,7 @@ export type Routes = {
165933
165858
  /** ID of the device. */
165934
165859
  device_id: string;
165935
165860
  /** Type of the device. The `august_lock` and `yale_lock` values are deprecated. Use `yale_access_lock` in place of `august_lock`, and `yale_access_lock` or `yale_home_lock` in place of `yale_lock`. */
165936
- device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_system' | 'hayward_pool');
165861
+ device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_controller' | 'hayward_pool');
165937
165862
  /** IDs of the spaces the device is in. */
165938
165863
  space_ids: string[];
165939
165864
  /** Optional nickname to describe the device, settable through Seam. */
@@ -166792,22 +166717,16 @@ export type Routes = {
166792
166717
  /** Models of the speakers bonded to this speaker, such as surrounds or a subwoofer. */
166793
166718
  bonded_member_models?: (string[] | undefined) | undefined;
166794
166719
  } | undefined) | undefined;
166795
- /** Metadata for a Hayward OmniLogic pool controller or body of water. */
166720
+ /** Metadata for a Hayward OmniLogic pool controller, pool, or spa. */
166796
166721
  hayward_omnilogic_metadata?: ({
166797
- /** ID of the Hayward OmniLogic system (the controller, called an MSP by Hayward) that the device belongs to. */
166722
+ /** ID of the Hayward OmniLogic controller that the device belongs to. */
166798
166723
  msp_system_id?: (string | undefined) | undefined;
166799
- /** Name of the system, as set in the Hayward OmniLogic app. */
166724
+ /** Name of the controller, as set in the Hayward OmniLogic app. */
166800
166725
  backyard_name?: (string | undefined) | undefined;
166801
- /** ID of the body of water within its system. Only present on a pool or spa body. */
166802
- body_of_water_id?: (string | undefined) | undefined;
166803
- /** Name of the body of water, as set in the Hayward OmniLogic app. Only present on a pool or spa body. */
166804
- body_of_water_name?: (string | undefined) | undefined;
166805
- /** ID of the virtual heater that carries the set point and heating request for the body of water. Only present on a pool or spa body. */
166806
- virtual_heater_id?: (string | undefined) | undefined;
166807
- /** Indicates whether the body of water shares its pump and heater with another body of water in the same system. */
166808
- is_shared_equipment?: (boolean | undefined) | undefined;
166809
- /** Priority of the body of water when it shares equipment. The `high` priority body, usually the spa, takes the shared heater when both request heat. */
166810
- shared_equipment_priority?: (('high' | 'low') | undefined) | undefined;
166726
+ /** ID of the pool or spa within its controller. Only present on a pool or spa. */
166727
+ system_id?: (string | undefined) | undefined;
166728
+ /** Name of the pool or spa, as set in the Hayward OmniLogic app. Only present on a pool or spa. */
166729
+ system_name?: (string | undefined) | undefined;
166811
166730
  } | undefined) | undefined;
166812
166731
  }) & ({
166813
166732
  /** Constraints on access codes for the device. Seam represents each constraint as an object with a `constraint_type` property. Depending on the constraint type, there may also be additional properties. Note that some constraints are manufacturer- or device-specific. */
@@ -166885,7 +166804,8 @@ export type Routes = {
166885
166804
  has_native_entry_events?: (boolean | undefined) | undefined;
166886
166805
  /** Indicates whether the lock is locked. */
166887
166806
  locked?: (boolean | undefined) | undefined;
166888
- /** Keypad battery status. */
166807
+ /** Keypad battery status.
166808
+ * @deprecated Use `accessory_keypad.battery` instead.*/
166889
166809
  keypad_battery?: ({
166890
166810
  /**
166891
166811
  Keypad battery charge level.
@@ -167759,7 +167679,7 @@ export type Routes = {
167759
167679
  /** ID of the device. */
167760
167680
  device_id: string;
167761
167681
  /** Type of the device. The `august_lock` and `yale_lock` values are deprecated. Use `yale_access_lock` in place of `august_lock`, and `yale_access_lock` or `yale_home_lock` in place of `yale_lock`. */
167762
- device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_system' | 'hayward_pool');
167682
+ device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_controller' | 'hayward_pool');
167763
167683
  /** IDs of the spaces the device is in. */
167764
167684
  space_ids: string[];
167765
167685
  /** Optional nickname to describe the device, settable through Seam. */
@@ -168618,22 +168538,16 @@ export type Routes = {
168618
168538
  /** Models of the speakers bonded to this speaker, such as surrounds or a subwoofer. */
168619
168539
  bonded_member_models?: (string[] | undefined) | undefined;
168620
168540
  } | undefined) | undefined;
168621
- /** Metadata for a Hayward OmniLogic pool controller or body of water. */
168541
+ /** Metadata for a Hayward OmniLogic pool controller, pool, or spa. */
168622
168542
  hayward_omnilogic_metadata?: ({
168623
- /** ID of the Hayward OmniLogic system (the controller, called an MSP by Hayward) that the device belongs to. */
168543
+ /** ID of the Hayward OmniLogic controller that the device belongs to. */
168624
168544
  msp_system_id?: (string | undefined) | undefined;
168625
- /** Name of the system, as set in the Hayward OmniLogic app. */
168545
+ /** Name of the controller, as set in the Hayward OmniLogic app. */
168626
168546
  backyard_name?: (string | undefined) | undefined;
168627
- /** ID of the body of water within its system. Only present on a pool or spa body. */
168628
- body_of_water_id?: (string | undefined) | undefined;
168629
- /** Name of the body of water, as set in the Hayward OmniLogic app. Only present on a pool or spa body. */
168630
- body_of_water_name?: (string | undefined) | undefined;
168631
- /** ID of the virtual heater that carries the set point and heating request for the body of water. Only present on a pool or spa body. */
168632
- virtual_heater_id?: (string | undefined) | undefined;
168633
- /** Indicates whether the body of water shares its pump and heater with another body of water in the same system. */
168634
- is_shared_equipment?: (boolean | undefined) | undefined;
168635
- /** Priority of the body of water when it shares equipment. The `high` priority body, usually the spa, takes the shared heater when both request heat. */
168636
- shared_equipment_priority?: (('high' | 'low') | undefined) | undefined;
168547
+ /** ID of the pool or spa within its controller. Only present on a pool or spa. */
168548
+ system_id?: (string | undefined) | undefined;
168549
+ /** Name of the pool or spa, as set in the Hayward OmniLogic app. Only present on a pool or spa. */
168550
+ system_name?: (string | undefined) | undefined;
168637
168551
  } | undefined) | undefined;
168638
168552
  }) & ({
168639
168553
  /** Constraints on access codes for the device. Seam represents each constraint as an object with a `constraint_type` property. Depending on the constraint type, there may also be additional properties. Note that some constraints are manufacturer- or device-specific. */
@@ -168711,7 +168625,8 @@ export type Routes = {
168711
168625
  has_native_entry_events?: (boolean | undefined) | undefined;
168712
168626
  /** Indicates whether the lock is locked. */
168713
168627
  locked?: (boolean | undefined) | undefined;
168714
- /** Keypad battery status. */
168628
+ /** Keypad battery status.
168629
+ * @deprecated Use `accessory_keypad.battery` instead.*/
168715
168630
  keypad_battery?: ({
168716
168631
  /**
168717
168632
  Keypad battery charge level.
@@ -171938,7 +171853,7 @@ export type Routes = {
171938
171853
  /** ID of the device. */
171939
171854
  device_id: string;
171940
171855
  /** Type of the device. The `august_lock` and `yale_lock` values are deprecated. Use `yale_access_lock` in place of `august_lock`, and `yale_access_lock` or `yale_home_lock` in place of `yale_lock`. */
171941
- device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_system' | 'hayward_pool');
171856
+ device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_controller' | 'hayward_pool');
171942
171857
  /** IDs of the spaces the device is in. */
171943
171858
  space_ids: string[];
171944
171859
  /** Optional nickname to describe the device, settable through Seam. */
@@ -172797,22 +172712,16 @@ export type Routes = {
172797
172712
  /** Models of the speakers bonded to this speaker, such as surrounds or a subwoofer. */
172798
172713
  bonded_member_models?: (string[] | undefined) | undefined;
172799
172714
  } | undefined) | undefined;
172800
- /** Metadata for a Hayward OmniLogic pool controller or body of water. */
172715
+ /** Metadata for a Hayward OmniLogic pool controller, pool, or spa. */
172801
172716
  hayward_omnilogic_metadata?: ({
172802
- /** ID of the Hayward OmniLogic system (the controller, called an MSP by Hayward) that the device belongs to. */
172717
+ /** ID of the Hayward OmniLogic controller that the device belongs to. */
172803
172718
  msp_system_id?: (string | undefined) | undefined;
172804
- /** Name of the system, as set in the Hayward OmniLogic app. */
172719
+ /** Name of the controller, as set in the Hayward OmniLogic app. */
172805
172720
  backyard_name?: (string | undefined) | undefined;
172806
- /** ID of the body of water within its system. Only present on a pool or spa body. */
172807
- body_of_water_id?: (string | undefined) | undefined;
172808
- /** Name of the body of water, as set in the Hayward OmniLogic app. Only present on a pool or spa body. */
172809
- body_of_water_name?: (string | undefined) | undefined;
172810
- /** ID of the virtual heater that carries the set point and heating request for the body of water. Only present on a pool or spa body. */
172811
- virtual_heater_id?: (string | undefined) | undefined;
172812
- /** Indicates whether the body of water shares its pump and heater with another body of water in the same system. */
172813
- is_shared_equipment?: (boolean | undefined) | undefined;
172814
- /** Priority of the body of water when it shares equipment. The `high` priority body, usually the spa, takes the shared heater when both request heat. */
172815
- shared_equipment_priority?: (('high' | 'low') | undefined) | undefined;
172721
+ /** ID of the pool or spa within its controller. Only present on a pool or spa. */
172722
+ system_id?: (string | undefined) | undefined;
172723
+ /** Name of the pool or spa, as set in the Hayward OmniLogic app. Only present on a pool or spa. */
172724
+ system_name?: (string | undefined) | undefined;
172816
172725
  } | undefined) | undefined;
172817
172726
  }) & ({
172818
172727
  /** Constraints on access codes for the device. Seam represents each constraint as an object with a `constraint_type` property. Depending on the constraint type, there may also be additional properties. Note that some constraints are manufacturer- or device-specific. */
@@ -172890,7 +172799,8 @@ export type Routes = {
172890
172799
  has_native_entry_events?: (boolean | undefined) | undefined;
172891
172800
  /** Indicates whether the lock is locked. */
172892
172801
  locked?: (boolean | undefined) | undefined;
172893
- /** Keypad battery status. */
172802
+ /** Keypad battery status.
172803
+ * @deprecated Use `accessory_keypad.battery` instead.*/
172894
172804
  keypad_battery?: ({
172895
172805
  /**
172896
172806
  Keypad battery charge level.
@@ -176506,16 +176416,16 @@ export type Routes = {
176506
176416
  result: null;
176507
176417
  /** Errors associated with the action attempt. Null for pending action attempts. */
176508
176418
  error: null;
176509
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
176510
- action_type: 'SET_POOL_HEATING';
176419
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
176420
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
176511
176421
  } | {
176512
176422
  /** ID of the action attempt. */
176513
176423
  action_attempt_id: string;
176514
176424
  status: 'success';
176515
176425
  /** Errors associated with the action attempt. Null for successful action attempts. */
176516
176426
  error: null;
176517
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
176518
- action_type: 'SET_POOL_HEATING';
176427
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
176428
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
176519
176429
  /** Result of the action. */
176520
176430
  result: {};
176521
176431
  } | {
@@ -176524,8 +176434,8 @@ export type Routes = {
176524
176434
  status: 'error';
176525
176435
  /** Result of the action attempt. Null for failed action attempts. */
176526
176436
  result: null;
176527
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
176528
- action_type: 'SET_POOL_HEATING';
176437
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
176438
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
176529
176439
  /** Error associated with the action. */
176530
176440
  error: {
176531
176441
  /** Type of the error. */
@@ -177259,7 +177169,7 @@ export type Routes = {
177259
177169
  /** ID of the device. */
177260
177170
  device_id: string;
177261
177171
  /** Type of the device. The `august_lock` and `yale_lock` values are deprecated. Use `yale_access_lock` in place of `august_lock`, and `yale_access_lock` or `yale_home_lock` in place of `yale_lock`. */
177262
- device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_system' | 'hayward_pool');
177172
+ device_type: ('akuvox_lock' | 'august_lock' | 'brivo_access_point' | 'butterflymx_panel' | 'avigilon_alta_entry' | 'doorking_lock' | 'genie_door' | 'igloo_lock' | 'linear_lock' | 'lockly_lock' | 'kwikset_lock' | 'nuki_lock' | 'salto_lock' | 'schlage_lock' | 'smartthings_lock' | 'wyze_lock' | 'yale_lock' | 'yale_access_lock' | 'yale_home_lock' | 'yale_connect_lock' | 'two_n_intercom' | 'controlbyweb_device' | 'ttlock_lock' | 'igloohome_lock' | 'four_suites_door' | 'dormakaba_oracode_door' | 'tedee_lock' | 'akiles_lock' | 'ultraloq_lock' | 'yacan_lock' | 'keyincode_lock' | 'omnitec_lock' | 'kisi_lock' | 'aqara_lock' | 'tuya_lock' | 'eufy_lock') | 'keynest_key' | ('noiseaware_activity_zone' | 'minut_sensor') | ('ecobee_thermostat' | 'nest_thermostat' | 'honeywell_resideo_thermostat' | 'tado_thermostat' | 'sensi_thermostat' | 'sensibo_thermostat' | 'smartthings_thermostat') | ('ios_phone' | 'android_phone') | ('ring_camera' | 'tapo_camera' | 'arlo_camera' | 'reolink_camera' | 'unifi_protect_camera') | 'sonos_speaker' | 'alertify_sensor' | ('hayward_pool_controller' | 'hayward_pool');
177263
177173
  /** Unique identifier for the account associated with the device. */
177264
177174
  connected_account_id: string;
177265
177175
  /** Location information for the device. */
@@ -185793,16 +185703,16 @@ export type Routes = {
185793
185703
  result: null;
185794
185704
  /** Errors associated with the action attempt. Null for pending action attempts. */
185795
185705
  error: null;
185796
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
185797
- action_type: 'SET_POOL_HEATING';
185706
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
185707
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
185798
185708
  } | {
185799
185709
  /** ID of the action attempt. */
185800
185710
  action_attempt_id: string;
185801
185711
  status: 'success';
185802
185712
  /** Errors associated with the action attempt. Null for successful action attempts. */
185803
185713
  error: null;
185804
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
185805
- action_type: 'SET_POOL_HEATING';
185714
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
185715
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
185806
185716
  /** Result of the action. */
185807
185717
  result: {};
185808
185718
  } | {
@@ -185811,8 +185721,8 @@ export type Routes = {
185811
185721
  status: 'error';
185812
185722
  /** Result of the action attempt. Null for failed action attempts. */
185813
185723
  result: null;
185814
- /** Action attempt to track the status of heating pool or spa water to a set point, or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
185815
- action_type: 'SET_POOL_HEATING';
185724
+ /** Action attempt to track the status of setting the mode of a temperature controller, such as heating pool or spa water to a set point or turning its heating off. The attempt succeeds only once the controller reports the requested state back. */
185725
+ action_type: 'SET_TEMPERATURE_CONTROLLER_MODE';
185816
185726
  /** Error associated with the action. */
185817
185727
  error: {
185818
185728
  /** Type of the error. */