@seamapi/types 1.1186.0 → 1.1187.0
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/lib/seam/connect/models/devices/capability-properties/index.d.ts +9 -9
- package/lib/seam/connect/models/devices/capability-properties/thermostat.d.ts +9 -9
- package/lib/seam/connect/models/devices/capability-properties/thermostat.js +3 -3
- package/lib/seam/connect/models/devices/capability-properties/thermostat.js.map +1 -1
- package/lib/seam/connect/models/devices/device.d.ts +173 -311
- package/lib/seam/connect/models/devices/device.js +60 -73
- package/lib/seam/connect/models/devices/device.js.map +1 -1
- package/lib/seam/connect/models/devices/unmanaged-device.d.ts +71 -169
- package/lib/seam/connect/openapi.js +166 -166
- package/lib/seam/connect/openapi.js.map +1 -1
- package/lib/seam/connect/route-types.d.ts +1003 -867
- package/package.json +1 -1
- package/src/lib/seam/connect/models/devices/capability-properties/thermostat.ts +3 -3
- package/src/lib/seam/connect/models/devices/device.ts +63 -76
- package/src/lib/seam/connect/openapi.ts +192 -190
- package/src/lib/seam/connect/route-types.ts +1037 -901
|
@@ -16230,58 +16230,9 @@ export type Routes = {
|
|
|
16230
16230
|
* @deprecated use offline_access_codes_enabled*/
|
|
16231
16231
|
supports_offline_access_codes?: boolean | undefined
|
|
16232
16232
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
16233
|
-
noise_level_decibels?:
|
|
16233
|
+
noise_level_decibels?: number | undefined
|
|
16234
16234
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
16235
16235
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
16236
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
16237
|
-
noise_level_nrs?: (number | null) | undefined
|
|
16238
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
16239
|
-
co2_ppm?: (number | null) | undefined
|
|
16240
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
16241
|
-
co_ppm?: (number | null) | undefined
|
|
16242
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
16243
|
-
air_quality_index?: (number | null) | undefined
|
|
16244
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
16245
|
-
mold_risk_level?: (string | null) | undefined
|
|
16246
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
16247
|
-
is_occupied?: (boolean | null) | undefined
|
|
16248
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
16249
|
-
occupant_count?: (number | null) | undefined
|
|
16250
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
16251
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
16252
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
16253
|
-
named_sensors?:
|
|
16254
|
-
| {
|
|
16255
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
16256
|
-
sensor_name: string
|
|
16257
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
16258
|
-
display_name: string
|
|
16259
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
16260
|
-
temperature_celsius?: (number | null) | undefined
|
|
16261
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
16262
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
16263
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
16264
|
-
relative_humidity?: (number | null) | undefined
|
|
16265
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
16266
|
-
noise_level_decibels?: (number | null) | undefined
|
|
16267
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
16268
|
-
noise_level_nrs?: (number | null) | undefined
|
|
16269
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
16270
|
-
co2_ppm?: (number | null) | undefined
|
|
16271
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
16272
|
-
co_ppm?: (number | null) | undefined
|
|
16273
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
16274
|
-
air_quality_index?: (number | null) | undefined
|
|
16275
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
16276
|
-
mold_risk_level?: (string | null) | undefined
|
|
16277
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
16278
|
-
is_occupied?: (boolean | null) | undefined
|
|
16279
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
16280
|
-
occupant_count?: (number | null) | undefined
|
|
16281
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
16282
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
16283
|
-
}[]
|
|
16284
|
-
| undefined
|
|
16285
16236
|
} & {
|
|
16286
16237
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
16287
16238
|
assa_abloy_credential_service_metadata?:
|
|
@@ -17374,11 +17325,11 @@ export type Routes = {
|
|
|
17374
17325
|
| undefined
|
|
17375
17326
|
} & {
|
|
17376
17327
|
/** Reported temperature in °F. */
|
|
17377
|
-
temperature_fahrenheit?:
|
|
17328
|
+
temperature_fahrenheit?: number | undefined
|
|
17378
17329
|
/** Reported temperature in °C. */
|
|
17379
|
-
temperature_celsius?:
|
|
17330
|
+
temperature_celsius?: number | undefined
|
|
17380
17331
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
17381
|
-
relative_humidity?:
|
|
17332
|
+
relative_humidity?: number | undefined
|
|
17382
17333
|
/** HVAC mode settings that the thermostat supports. */
|
|
17383
17334
|
available_hvac_mode_settings?:
|
|
17384
17335
|
| ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[]
|
|
@@ -18213,6 +18164,63 @@ export type Routes = {
|
|
|
18213
18164
|
image_url?: string | undefined
|
|
18214
18165
|
}
|
|
18215
18166
|
| undefined
|
|
18167
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
18168
|
+
temperature_celsius?: number | undefined
|
|
18169
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
18170
|
+
temperature_fahrenheit?: number | undefined
|
|
18171
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
18172
|
+
relative_humidity?: number | undefined
|
|
18173
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
18174
|
+
noise_level_decibels?: number | undefined
|
|
18175
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
18176
|
+
noise_level_nrs?: number | undefined
|
|
18177
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
18178
|
+
co2_ppm?: number | undefined
|
|
18179
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
18180
|
+
co_ppm?: number | undefined
|
|
18181
|
+
/** Air quality index, if the device measures it. */
|
|
18182
|
+
air_quality_index?: number | undefined
|
|
18183
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
18184
|
+
mold_risk_level?: string | undefined
|
|
18185
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
18186
|
+
is_occupied?: boolean | undefined
|
|
18187
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
18188
|
+
occupant_count?: number | undefined
|
|
18189
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
18190
|
+
is_smoking_detected?: boolean | undefined
|
|
18191
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
18192
|
+
named_sensors?:
|
|
18193
|
+
| {
|
|
18194
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
18195
|
+
sensor_name: string
|
|
18196
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
18197
|
+
display_name: string
|
|
18198
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
18199
|
+
temperature_celsius?: number | undefined
|
|
18200
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
18201
|
+
temperature_fahrenheit?: number | undefined
|
|
18202
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
18203
|
+
relative_humidity?: number | undefined
|
|
18204
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
18205
|
+
noise_level_decibels?: number | undefined
|
|
18206
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
18207
|
+
noise_level_nrs?: number | undefined
|
|
18208
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
18209
|
+
co2_ppm?: number | undefined
|
|
18210
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
18211
|
+
co_ppm?: number | undefined
|
|
18212
|
+
/** Air quality index, if the device measures it. */
|
|
18213
|
+
air_quality_index?: number | undefined
|
|
18214
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
18215
|
+
mold_risk_level?: string | undefined
|
|
18216
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
18217
|
+
is_occupied?: boolean | undefined
|
|
18218
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
18219
|
+
occupant_count?: number | undefined
|
|
18220
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
18221
|
+
is_smoking_detected?: boolean | undefined
|
|
18222
|
+
}[]
|
|
18223
|
+
| undefined
|
|
18216
18224
|
/** Indicates whether the device supports remote unlocking. */
|
|
18217
18225
|
can_remotely_unlock?: boolean | undefined
|
|
18218
18226
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -26067,58 +26075,9 @@ export type Routes = {
|
|
|
26067
26075
|
* @deprecated use offline_access_codes_enabled*/
|
|
26068
26076
|
supports_offline_access_codes?: boolean | undefined
|
|
26069
26077
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
26070
|
-
noise_level_decibels?:
|
|
26078
|
+
noise_level_decibels?: number | undefined
|
|
26071
26079
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
26072
26080
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
26073
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
26074
|
-
noise_level_nrs?: (number | null) | undefined
|
|
26075
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
26076
|
-
co2_ppm?: (number | null) | undefined
|
|
26077
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
26078
|
-
co_ppm?: (number | null) | undefined
|
|
26079
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
26080
|
-
air_quality_index?: (number | null) | undefined
|
|
26081
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
26082
|
-
mold_risk_level?: (string | null) | undefined
|
|
26083
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
26084
|
-
is_occupied?: (boolean | null) | undefined
|
|
26085
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
26086
|
-
occupant_count?: (number | null) | undefined
|
|
26087
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
26088
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
26089
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
26090
|
-
named_sensors?:
|
|
26091
|
-
| {
|
|
26092
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
26093
|
-
sensor_name: string
|
|
26094
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
26095
|
-
display_name: string
|
|
26096
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
26097
|
-
temperature_celsius?: (number | null) | undefined
|
|
26098
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
26099
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
26100
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
26101
|
-
relative_humidity?: (number | null) | undefined
|
|
26102
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
26103
|
-
noise_level_decibels?: (number | null) | undefined
|
|
26104
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
26105
|
-
noise_level_nrs?: (number | null) | undefined
|
|
26106
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
26107
|
-
co2_ppm?: (number | null) | undefined
|
|
26108
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
26109
|
-
co_ppm?: (number | null) | undefined
|
|
26110
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
26111
|
-
air_quality_index?: (number | null) | undefined
|
|
26112
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
26113
|
-
mold_risk_level?: (string | null) | undefined
|
|
26114
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
26115
|
-
is_occupied?: (boolean | null) | undefined
|
|
26116
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
26117
|
-
occupant_count?: (number | null) | undefined
|
|
26118
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
26119
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
26120
|
-
}[]
|
|
26121
|
-
| undefined
|
|
26122
26081
|
} & {
|
|
26123
26082
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
26124
26083
|
assa_abloy_credential_service_metadata?:
|
|
@@ -27211,11 +27170,11 @@ export type Routes = {
|
|
|
27211
27170
|
| undefined
|
|
27212
27171
|
} & {
|
|
27213
27172
|
/** Reported temperature in °F. */
|
|
27214
|
-
temperature_fahrenheit?:
|
|
27173
|
+
temperature_fahrenheit?: number | undefined
|
|
27215
27174
|
/** Reported temperature in °C. */
|
|
27216
|
-
temperature_celsius?:
|
|
27175
|
+
temperature_celsius?: number | undefined
|
|
27217
27176
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
27218
|
-
relative_humidity?:
|
|
27177
|
+
relative_humidity?: number | undefined
|
|
27219
27178
|
/** HVAC mode settings that the thermostat supports. */
|
|
27220
27179
|
available_hvac_mode_settings?:
|
|
27221
27180
|
| ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[]
|
|
@@ -28050,6 +28009,63 @@ export type Routes = {
|
|
|
28050
28009
|
image_url?: string | undefined
|
|
28051
28010
|
}
|
|
28052
28011
|
| undefined
|
|
28012
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
28013
|
+
temperature_celsius?: number | undefined
|
|
28014
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
28015
|
+
temperature_fahrenheit?: number | undefined
|
|
28016
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
28017
|
+
relative_humidity?: number | undefined
|
|
28018
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
28019
|
+
noise_level_decibels?: number | undefined
|
|
28020
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
28021
|
+
noise_level_nrs?: number | undefined
|
|
28022
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
28023
|
+
co2_ppm?: number | undefined
|
|
28024
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
28025
|
+
co_ppm?: number | undefined
|
|
28026
|
+
/** Air quality index, if the device measures it. */
|
|
28027
|
+
air_quality_index?: number | undefined
|
|
28028
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
28029
|
+
mold_risk_level?: string | undefined
|
|
28030
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
28031
|
+
is_occupied?: boolean | undefined
|
|
28032
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
28033
|
+
occupant_count?: number | undefined
|
|
28034
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
28035
|
+
is_smoking_detected?: boolean | undefined
|
|
28036
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
28037
|
+
named_sensors?:
|
|
28038
|
+
| {
|
|
28039
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
28040
|
+
sensor_name: string
|
|
28041
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
28042
|
+
display_name: string
|
|
28043
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
28044
|
+
temperature_celsius?: number | undefined
|
|
28045
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
28046
|
+
temperature_fahrenheit?: number | undefined
|
|
28047
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
28048
|
+
relative_humidity?: number | undefined
|
|
28049
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
28050
|
+
noise_level_decibels?: number | undefined
|
|
28051
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
28052
|
+
noise_level_nrs?: number | undefined
|
|
28053
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
28054
|
+
co2_ppm?: number | undefined
|
|
28055
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
28056
|
+
co_ppm?: number | undefined
|
|
28057
|
+
/** Air quality index, if the device measures it. */
|
|
28058
|
+
air_quality_index?: number | undefined
|
|
28059
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
28060
|
+
mold_risk_level?: string | undefined
|
|
28061
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
28062
|
+
is_occupied?: boolean | undefined
|
|
28063
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
28064
|
+
occupant_count?: number | undefined
|
|
28065
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
28066
|
+
is_smoking_detected?: boolean | undefined
|
|
28067
|
+
}[]
|
|
28068
|
+
| undefined
|
|
28053
28069
|
/** Indicates whether the device supports remote unlocking. */
|
|
28054
28070
|
can_remotely_unlock?: boolean | undefined
|
|
28055
28071
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -58385,58 +58401,9 @@ export type Routes = {
|
|
|
58385
58401
|
* @deprecated use offline_access_codes_enabled*/
|
|
58386
58402
|
supports_offline_access_codes?: boolean | undefined
|
|
58387
58403
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
58388
|
-
noise_level_decibels?:
|
|
58404
|
+
noise_level_decibels?: number | undefined
|
|
58389
58405
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
58390
58406
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
58391
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
58392
|
-
noise_level_nrs?: (number | null) | undefined
|
|
58393
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
58394
|
-
co2_ppm?: (number | null) | undefined
|
|
58395
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
58396
|
-
co_ppm?: (number | null) | undefined
|
|
58397
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
58398
|
-
air_quality_index?: (number | null) | undefined
|
|
58399
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
58400
|
-
mold_risk_level?: (string | null) | undefined
|
|
58401
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
58402
|
-
is_occupied?: (boolean | null) | undefined
|
|
58403
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
58404
|
-
occupant_count?: (number | null) | undefined
|
|
58405
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
58406
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
58407
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
58408
|
-
named_sensors?:
|
|
58409
|
-
| {
|
|
58410
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
58411
|
-
sensor_name: string
|
|
58412
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
58413
|
-
display_name: string
|
|
58414
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
58415
|
-
temperature_celsius?: (number | null) | undefined
|
|
58416
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
58417
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
58418
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
58419
|
-
relative_humidity?: (number | null) | undefined
|
|
58420
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
58421
|
-
noise_level_decibels?: (number | null) | undefined
|
|
58422
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
58423
|
-
noise_level_nrs?: (number | null) | undefined
|
|
58424
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
58425
|
-
co2_ppm?: (number | null) | undefined
|
|
58426
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
58427
|
-
co_ppm?: (number | null) | undefined
|
|
58428
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
58429
|
-
air_quality_index?: (number | null) | undefined
|
|
58430
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
58431
|
-
mold_risk_level?: (string | null) | undefined
|
|
58432
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
58433
|
-
is_occupied?: (boolean | null) | undefined
|
|
58434
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
58435
|
-
occupant_count?: (number | null) | undefined
|
|
58436
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
58437
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
58438
|
-
}[]
|
|
58439
|
-
| undefined
|
|
58440
58407
|
} & {
|
|
58441
58408
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
58442
58409
|
assa_abloy_credential_service_metadata?:
|
|
@@ -59494,11 +59461,11 @@ export type Routes = {
|
|
|
59494
59461
|
| undefined
|
|
59495
59462
|
} & {
|
|
59496
59463
|
/** Reported temperature in °F. */
|
|
59497
|
-
temperature_fahrenheit?:
|
|
59464
|
+
temperature_fahrenheit?: number | undefined
|
|
59498
59465
|
/** Reported temperature in °C. */
|
|
59499
|
-
temperature_celsius?:
|
|
59466
|
+
temperature_celsius?: number | undefined
|
|
59500
59467
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
59501
|
-
relative_humidity?:
|
|
59468
|
+
relative_humidity?: number | undefined
|
|
59502
59469
|
/** HVAC mode settings that the thermostat supports. */
|
|
59503
59470
|
available_hvac_mode_settings?:
|
|
59504
59471
|
('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined
|
|
@@ -60311,6 +60278,63 @@ export type Routes = {
|
|
|
60311
60278
|
image_url?: string | undefined
|
|
60312
60279
|
}
|
|
60313
60280
|
| undefined
|
|
60281
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
60282
|
+
temperature_celsius?: number | undefined
|
|
60283
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
60284
|
+
temperature_fahrenheit?: number | undefined
|
|
60285
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
60286
|
+
relative_humidity?: number | undefined
|
|
60287
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
60288
|
+
noise_level_decibels?: number | undefined
|
|
60289
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
60290
|
+
noise_level_nrs?: number | undefined
|
|
60291
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
60292
|
+
co2_ppm?: number | undefined
|
|
60293
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
60294
|
+
co_ppm?: number | undefined
|
|
60295
|
+
/** Air quality index, if the device measures it. */
|
|
60296
|
+
air_quality_index?: number | undefined
|
|
60297
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
60298
|
+
mold_risk_level?: string | undefined
|
|
60299
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
60300
|
+
is_occupied?: boolean | undefined
|
|
60301
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
60302
|
+
occupant_count?: number | undefined
|
|
60303
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
60304
|
+
is_smoking_detected?: boolean | undefined
|
|
60305
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
60306
|
+
named_sensors?:
|
|
60307
|
+
| {
|
|
60308
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
60309
|
+
sensor_name: string
|
|
60310
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
60311
|
+
display_name: string
|
|
60312
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
60313
|
+
temperature_celsius?: number | undefined
|
|
60314
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
60315
|
+
temperature_fahrenheit?: number | undefined
|
|
60316
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
60317
|
+
relative_humidity?: number | undefined
|
|
60318
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
60319
|
+
noise_level_decibels?: number | undefined
|
|
60320
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
60321
|
+
noise_level_nrs?: number | undefined
|
|
60322
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
60323
|
+
co2_ppm?: number | undefined
|
|
60324
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
60325
|
+
co_ppm?: number | undefined
|
|
60326
|
+
/** Air quality index, if the device measures it. */
|
|
60327
|
+
air_quality_index?: number | undefined
|
|
60328
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
60329
|
+
mold_risk_level?: string | undefined
|
|
60330
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
60331
|
+
is_occupied?: boolean | undefined
|
|
60332
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
60333
|
+
occupant_count?: number | undefined
|
|
60334
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
60335
|
+
is_smoking_detected?: boolean | undefined
|
|
60336
|
+
}[]
|
|
60337
|
+
| undefined
|
|
60314
60338
|
/** Indicates whether the device supports remote unlocking. */
|
|
60315
60339
|
can_remotely_unlock?: boolean | undefined
|
|
60316
60340
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -60847,58 +60871,9 @@ export type Routes = {
|
|
|
60847
60871
|
* @deprecated use offline_access_codes_enabled*/
|
|
60848
60872
|
supports_offline_access_codes?: boolean | undefined
|
|
60849
60873
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
60850
|
-
noise_level_decibels?:
|
|
60874
|
+
noise_level_decibels?: number | undefined
|
|
60851
60875
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
60852
60876
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
60853
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
60854
|
-
noise_level_nrs?: (number | null) | undefined
|
|
60855
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
60856
|
-
co2_ppm?: (number | null) | undefined
|
|
60857
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
60858
|
-
co_ppm?: (number | null) | undefined
|
|
60859
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
60860
|
-
air_quality_index?: (number | null) | undefined
|
|
60861
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
60862
|
-
mold_risk_level?: (string | null) | undefined
|
|
60863
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
60864
|
-
is_occupied?: (boolean | null) | undefined
|
|
60865
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
60866
|
-
occupant_count?: (number | null) | undefined
|
|
60867
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
60868
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
60869
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
60870
|
-
named_sensors?:
|
|
60871
|
-
| {
|
|
60872
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
60873
|
-
sensor_name: string
|
|
60874
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
60875
|
-
display_name: string
|
|
60876
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
60877
|
-
temperature_celsius?: (number | null) | undefined
|
|
60878
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
60879
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
60880
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
60881
|
-
relative_humidity?: (number | null) | undefined
|
|
60882
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
60883
|
-
noise_level_decibels?: (number | null) | undefined
|
|
60884
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
60885
|
-
noise_level_nrs?: (number | null) | undefined
|
|
60886
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
60887
|
-
co2_ppm?: (number | null) | undefined
|
|
60888
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
60889
|
-
co_ppm?: (number | null) | undefined
|
|
60890
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
60891
|
-
air_quality_index?: (number | null) | undefined
|
|
60892
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
60893
|
-
mold_risk_level?: (string | null) | undefined
|
|
60894
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
60895
|
-
is_occupied?: (boolean | null) | undefined
|
|
60896
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
60897
|
-
occupant_count?: (number | null) | undefined
|
|
60898
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
60899
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
60900
|
-
}[]
|
|
60901
|
-
| undefined
|
|
60902
60877
|
} & {
|
|
60903
60878
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
60904
60879
|
assa_abloy_credential_service_metadata?:
|
|
@@ -61956,11 +61931,11 @@ export type Routes = {
|
|
|
61956
61931
|
| undefined
|
|
61957
61932
|
} & {
|
|
61958
61933
|
/** Reported temperature in °F. */
|
|
61959
|
-
temperature_fahrenheit?:
|
|
61934
|
+
temperature_fahrenheit?: number | undefined
|
|
61960
61935
|
/** Reported temperature in °C. */
|
|
61961
|
-
temperature_celsius?:
|
|
61936
|
+
temperature_celsius?: number | undefined
|
|
61962
61937
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
61963
|
-
relative_humidity?:
|
|
61938
|
+
relative_humidity?: number | undefined
|
|
61964
61939
|
/** HVAC mode settings that the thermostat supports. */
|
|
61965
61940
|
available_hvac_mode_settings?:
|
|
61966
61941
|
('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined
|
|
@@ -62773,6 +62748,63 @@ export type Routes = {
|
|
|
62773
62748
|
image_url?: string | undefined
|
|
62774
62749
|
}
|
|
62775
62750
|
| undefined
|
|
62751
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
62752
|
+
temperature_celsius?: number | undefined
|
|
62753
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
62754
|
+
temperature_fahrenheit?: number | undefined
|
|
62755
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
62756
|
+
relative_humidity?: number | undefined
|
|
62757
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
62758
|
+
noise_level_decibels?: number | undefined
|
|
62759
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
62760
|
+
noise_level_nrs?: number | undefined
|
|
62761
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
62762
|
+
co2_ppm?: number | undefined
|
|
62763
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
62764
|
+
co_ppm?: number | undefined
|
|
62765
|
+
/** Air quality index, if the device measures it. */
|
|
62766
|
+
air_quality_index?: number | undefined
|
|
62767
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
62768
|
+
mold_risk_level?: string | undefined
|
|
62769
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
62770
|
+
is_occupied?: boolean | undefined
|
|
62771
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
62772
|
+
occupant_count?: number | undefined
|
|
62773
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
62774
|
+
is_smoking_detected?: boolean | undefined
|
|
62775
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
62776
|
+
named_sensors?:
|
|
62777
|
+
| {
|
|
62778
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
62779
|
+
sensor_name: string
|
|
62780
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
62781
|
+
display_name: string
|
|
62782
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
62783
|
+
temperature_celsius?: number | undefined
|
|
62784
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
62785
|
+
temperature_fahrenheit?: number | undefined
|
|
62786
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
62787
|
+
relative_humidity?: number | undefined
|
|
62788
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
62789
|
+
noise_level_decibels?: number | undefined
|
|
62790
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
62791
|
+
noise_level_nrs?: number | undefined
|
|
62792
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
62793
|
+
co2_ppm?: number | undefined
|
|
62794
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
62795
|
+
co_ppm?: number | undefined
|
|
62796
|
+
/** Air quality index, if the device measures it. */
|
|
62797
|
+
air_quality_index?: number | undefined
|
|
62798
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
62799
|
+
mold_risk_level?: string | undefined
|
|
62800
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
62801
|
+
is_occupied?: boolean | undefined
|
|
62802
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
62803
|
+
occupant_count?: number | undefined
|
|
62804
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
62805
|
+
is_smoking_detected?: boolean | undefined
|
|
62806
|
+
}[]
|
|
62807
|
+
| undefined
|
|
62776
62808
|
/** Indicates whether the device supports remote unlocking. */
|
|
62777
62809
|
can_remotely_unlock?: boolean | undefined
|
|
62778
62810
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -77670,58 +77702,9 @@ export type Routes = {
|
|
|
77670
77702
|
* @deprecated use offline_access_codes_enabled*/
|
|
77671
77703
|
supports_offline_access_codes?: boolean | undefined
|
|
77672
77704
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
77673
|
-
noise_level_decibels?:
|
|
77705
|
+
noise_level_decibels?: number | undefined
|
|
77674
77706
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
77675
77707
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
77676
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
77677
|
-
noise_level_nrs?: (number | null) | undefined
|
|
77678
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
77679
|
-
co2_ppm?: (number | null) | undefined
|
|
77680
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
77681
|
-
co_ppm?: (number | null) | undefined
|
|
77682
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
77683
|
-
air_quality_index?: (number | null) | undefined
|
|
77684
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
77685
|
-
mold_risk_level?: (string | null) | undefined
|
|
77686
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
77687
|
-
is_occupied?: (boolean | null) | undefined
|
|
77688
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
77689
|
-
occupant_count?: (number | null) | undefined
|
|
77690
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
77691
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
77692
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
77693
|
-
named_sensors?:
|
|
77694
|
-
| {
|
|
77695
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
77696
|
-
sensor_name: string
|
|
77697
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
77698
|
-
display_name: string
|
|
77699
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
77700
|
-
temperature_celsius?: (number | null) | undefined
|
|
77701
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
77702
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
77703
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
77704
|
-
relative_humidity?: (number | null) | undefined
|
|
77705
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
77706
|
-
noise_level_decibels?: (number | null) | undefined
|
|
77707
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
77708
|
-
noise_level_nrs?: (number | null) | undefined
|
|
77709
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
77710
|
-
co2_ppm?: (number | null) | undefined
|
|
77711
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
77712
|
-
co_ppm?: (number | null) | undefined
|
|
77713
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
77714
|
-
air_quality_index?: (number | null) | undefined
|
|
77715
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
77716
|
-
mold_risk_level?: (string | null) | undefined
|
|
77717
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
77718
|
-
is_occupied?: (boolean | null) | undefined
|
|
77719
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
77720
|
-
occupant_count?: (number | null) | undefined
|
|
77721
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
77722
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
77723
|
-
}[]
|
|
77724
|
-
| undefined
|
|
77725
77708
|
} & {
|
|
77726
77709
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
77727
77710
|
assa_abloy_credential_service_metadata?:
|
|
@@ -78779,11 +78762,11 @@ export type Routes = {
|
|
|
78779
78762
|
| undefined
|
|
78780
78763
|
} & {
|
|
78781
78764
|
/** Reported temperature in °F. */
|
|
78782
|
-
temperature_fahrenheit?:
|
|
78765
|
+
temperature_fahrenheit?: number | undefined
|
|
78783
78766
|
/** Reported temperature in °C. */
|
|
78784
|
-
temperature_celsius?:
|
|
78767
|
+
temperature_celsius?: number | undefined
|
|
78785
78768
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
78786
|
-
relative_humidity?:
|
|
78769
|
+
relative_humidity?: number | undefined
|
|
78787
78770
|
/** HVAC mode settings that the thermostat supports. */
|
|
78788
78771
|
available_hvac_mode_settings?:
|
|
78789
78772
|
('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined
|
|
@@ -79596,6 +79579,63 @@ export type Routes = {
|
|
|
79596
79579
|
image_url?: string | undefined
|
|
79597
79580
|
}
|
|
79598
79581
|
| undefined
|
|
79582
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
79583
|
+
temperature_celsius?: number | undefined
|
|
79584
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
79585
|
+
temperature_fahrenheit?: number | undefined
|
|
79586
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
79587
|
+
relative_humidity?: number | undefined
|
|
79588
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
79589
|
+
noise_level_decibels?: number | undefined
|
|
79590
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
79591
|
+
noise_level_nrs?: number | undefined
|
|
79592
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
79593
|
+
co2_ppm?: number | undefined
|
|
79594
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
79595
|
+
co_ppm?: number | undefined
|
|
79596
|
+
/** Air quality index, if the device measures it. */
|
|
79597
|
+
air_quality_index?: number | undefined
|
|
79598
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
79599
|
+
mold_risk_level?: string | undefined
|
|
79600
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
79601
|
+
is_occupied?: boolean | undefined
|
|
79602
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
79603
|
+
occupant_count?: number | undefined
|
|
79604
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
79605
|
+
is_smoking_detected?: boolean | undefined
|
|
79606
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
79607
|
+
named_sensors?:
|
|
79608
|
+
| {
|
|
79609
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
79610
|
+
sensor_name: string
|
|
79611
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
79612
|
+
display_name: string
|
|
79613
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
79614
|
+
temperature_celsius?: number | undefined
|
|
79615
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
79616
|
+
temperature_fahrenheit?: number | undefined
|
|
79617
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
79618
|
+
relative_humidity?: number | undefined
|
|
79619
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
79620
|
+
noise_level_decibels?: number | undefined
|
|
79621
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
79622
|
+
noise_level_nrs?: number | undefined
|
|
79623
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
79624
|
+
co2_ppm?: number | undefined
|
|
79625
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
79626
|
+
co_ppm?: number | undefined
|
|
79627
|
+
/** Air quality index, if the device measures it. */
|
|
79628
|
+
air_quality_index?: number | undefined
|
|
79629
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
79630
|
+
mold_risk_level?: string | undefined
|
|
79631
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
79632
|
+
is_occupied?: boolean | undefined
|
|
79633
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
79634
|
+
occupant_count?: number | undefined
|
|
79635
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
79636
|
+
is_smoking_detected?: boolean | undefined
|
|
79637
|
+
}[]
|
|
79638
|
+
| undefined
|
|
79599
79639
|
/** Indicates whether the device supports remote unlocking. */
|
|
79600
79640
|
can_remotely_unlock?: boolean | undefined
|
|
79601
79641
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -79829,58 +79869,9 @@ export type Routes = {
|
|
|
79829
79869
|
* @deprecated use offline_access_codes_enabled*/
|
|
79830
79870
|
supports_offline_access_codes?: boolean | undefined
|
|
79831
79871
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
79832
|
-
noise_level_decibels?:
|
|
79872
|
+
noise_level_decibels?: number | undefined
|
|
79833
79873
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
79834
79874
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
79835
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
79836
|
-
noise_level_nrs?: (number | null) | undefined
|
|
79837
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
79838
|
-
co2_ppm?: (number | null) | undefined
|
|
79839
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
79840
|
-
co_ppm?: (number | null) | undefined
|
|
79841
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
79842
|
-
air_quality_index?: (number | null) | undefined
|
|
79843
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
79844
|
-
mold_risk_level?: (string | null) | undefined
|
|
79845
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
79846
|
-
is_occupied?: (boolean | null) | undefined
|
|
79847
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
79848
|
-
occupant_count?: (number | null) | undefined
|
|
79849
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
79850
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
79851
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
79852
|
-
named_sensors?:
|
|
79853
|
-
| {
|
|
79854
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
79855
|
-
sensor_name: string
|
|
79856
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
79857
|
-
display_name: string
|
|
79858
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
79859
|
-
temperature_celsius?: (number | null) | undefined
|
|
79860
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
79861
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
79862
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
79863
|
-
relative_humidity?: (number | null) | undefined
|
|
79864
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
79865
|
-
noise_level_decibels?: (number | null) | undefined
|
|
79866
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
79867
|
-
noise_level_nrs?: (number | null) | undefined
|
|
79868
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
79869
|
-
co2_ppm?: (number | null) | undefined
|
|
79870
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
79871
|
-
co_ppm?: (number | null) | undefined
|
|
79872
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
79873
|
-
air_quality_index?: (number | null) | undefined
|
|
79874
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
79875
|
-
mold_risk_level?: (string | null) | undefined
|
|
79876
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
79877
|
-
is_occupied?: (boolean | null) | undefined
|
|
79878
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
79879
|
-
occupant_count?: (number | null) | undefined
|
|
79880
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
79881
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
79882
|
-
}[]
|
|
79883
|
-
| undefined
|
|
79884
79875
|
} & {
|
|
79885
79876
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
79886
79877
|
assa_abloy_credential_service_metadata?:
|
|
@@ -80938,11 +80929,11 @@ export type Routes = {
|
|
|
80938
80929
|
| undefined
|
|
80939
80930
|
} & {
|
|
80940
80931
|
/** Reported temperature in °F. */
|
|
80941
|
-
temperature_fahrenheit?:
|
|
80932
|
+
temperature_fahrenheit?: number | undefined
|
|
80942
80933
|
/** Reported temperature in °C. */
|
|
80943
|
-
temperature_celsius?:
|
|
80934
|
+
temperature_celsius?: number | undefined
|
|
80944
80935
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
80945
|
-
relative_humidity?:
|
|
80936
|
+
relative_humidity?: number | undefined
|
|
80946
80937
|
/** HVAC mode settings that the thermostat supports. */
|
|
80947
80938
|
available_hvac_mode_settings?:
|
|
80948
80939
|
('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined
|
|
@@ -81755,6 +81746,63 @@ export type Routes = {
|
|
|
81755
81746
|
image_url?: string | undefined
|
|
81756
81747
|
}
|
|
81757
81748
|
| undefined
|
|
81749
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
81750
|
+
temperature_celsius?: number | undefined
|
|
81751
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
81752
|
+
temperature_fahrenheit?: number | undefined
|
|
81753
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
81754
|
+
relative_humidity?: number | undefined
|
|
81755
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
81756
|
+
noise_level_decibels?: number | undefined
|
|
81757
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
81758
|
+
noise_level_nrs?: number | undefined
|
|
81759
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
81760
|
+
co2_ppm?: number | undefined
|
|
81761
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
81762
|
+
co_ppm?: number | undefined
|
|
81763
|
+
/** Air quality index, if the device measures it. */
|
|
81764
|
+
air_quality_index?: number | undefined
|
|
81765
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
81766
|
+
mold_risk_level?: string | undefined
|
|
81767
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
81768
|
+
is_occupied?: boolean | undefined
|
|
81769
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
81770
|
+
occupant_count?: number | undefined
|
|
81771
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
81772
|
+
is_smoking_detected?: boolean | undefined
|
|
81773
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
81774
|
+
named_sensors?:
|
|
81775
|
+
| {
|
|
81776
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
81777
|
+
sensor_name: string
|
|
81778
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
81779
|
+
display_name: string
|
|
81780
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
81781
|
+
temperature_celsius?: number | undefined
|
|
81782
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
81783
|
+
temperature_fahrenheit?: number | undefined
|
|
81784
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
81785
|
+
relative_humidity?: number | undefined
|
|
81786
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
81787
|
+
noise_level_decibels?: number | undefined
|
|
81788
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
81789
|
+
noise_level_nrs?: number | undefined
|
|
81790
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
81791
|
+
co2_ppm?: number | undefined
|
|
81792
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
81793
|
+
co_ppm?: number | undefined
|
|
81794
|
+
/** Air quality index, if the device measures it. */
|
|
81795
|
+
air_quality_index?: number | undefined
|
|
81796
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
81797
|
+
mold_risk_level?: string | undefined
|
|
81798
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
81799
|
+
is_occupied?: boolean | undefined
|
|
81800
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
81801
|
+
occupant_count?: number | undefined
|
|
81802
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
81803
|
+
is_smoking_detected?: boolean | undefined
|
|
81804
|
+
}[]
|
|
81805
|
+
| undefined
|
|
81758
81806
|
/** Indicates whether the device supports remote unlocking. */
|
|
81759
81807
|
can_remotely_unlock?: boolean | undefined
|
|
81760
81808
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -82126,58 +82174,9 @@ export type Routes = {
|
|
|
82126
82174
|
* @deprecated use offline_access_codes_enabled*/
|
|
82127
82175
|
supports_offline_access_codes?: boolean | undefined
|
|
82128
82176
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
82129
|
-
noise_level_decibels?:
|
|
82177
|
+
noise_level_decibels?: number | undefined
|
|
82130
82178
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
82131
82179
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
82132
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
82133
|
-
noise_level_nrs?: (number | null) | undefined
|
|
82134
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
82135
|
-
co2_ppm?: (number | null) | undefined
|
|
82136
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
82137
|
-
co_ppm?: (number | null) | undefined
|
|
82138
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
82139
|
-
air_quality_index?: (number | null) | undefined
|
|
82140
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
82141
|
-
mold_risk_level?: (string | null) | undefined
|
|
82142
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
82143
|
-
is_occupied?: (boolean | null) | undefined
|
|
82144
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
82145
|
-
occupant_count?: (number | null) | undefined
|
|
82146
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
82147
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
82148
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
82149
|
-
named_sensors?:
|
|
82150
|
-
| {
|
|
82151
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
82152
|
-
sensor_name: string
|
|
82153
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
82154
|
-
display_name: string
|
|
82155
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
82156
|
-
temperature_celsius?: (number | null) | undefined
|
|
82157
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
82158
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
82159
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
82160
|
-
relative_humidity?: (number | null) | undefined
|
|
82161
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
82162
|
-
noise_level_decibels?: (number | null) | undefined
|
|
82163
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
82164
|
-
noise_level_nrs?: (number | null) | undefined
|
|
82165
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
82166
|
-
co2_ppm?: (number | null) | undefined
|
|
82167
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
82168
|
-
co_ppm?: (number | null) | undefined
|
|
82169
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
82170
|
-
air_quality_index?: (number | null) | undefined
|
|
82171
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
82172
|
-
mold_risk_level?: (string | null) | undefined
|
|
82173
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
82174
|
-
is_occupied?: (boolean | null) | undefined
|
|
82175
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
82176
|
-
occupant_count?: (number | null) | undefined
|
|
82177
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
82178
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
82179
|
-
}[]
|
|
82180
|
-
| undefined
|
|
82181
82180
|
} & {
|
|
82182
82181
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
82183
82182
|
assa_abloy_credential_service_metadata?:
|
|
@@ -83235,11 +83234,11 @@ export type Routes = {
|
|
|
83235
83234
|
| undefined
|
|
83236
83235
|
} & {
|
|
83237
83236
|
/** Reported temperature in °F. */
|
|
83238
|
-
temperature_fahrenheit?:
|
|
83237
|
+
temperature_fahrenheit?: number | undefined
|
|
83239
83238
|
/** Reported temperature in °C. */
|
|
83240
|
-
temperature_celsius?:
|
|
83239
|
+
temperature_celsius?: number | undefined
|
|
83241
83240
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
83242
|
-
relative_humidity?:
|
|
83241
|
+
relative_humidity?: number | undefined
|
|
83243
83242
|
/** HVAC mode settings that the thermostat supports. */
|
|
83244
83243
|
available_hvac_mode_settings?:
|
|
83245
83244
|
('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined
|
|
@@ -84052,6 +84051,63 @@ export type Routes = {
|
|
|
84052
84051
|
image_url?: string | undefined
|
|
84053
84052
|
}
|
|
84054
84053
|
| undefined
|
|
84054
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
84055
|
+
temperature_celsius?: number | undefined
|
|
84056
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
84057
|
+
temperature_fahrenheit?: number | undefined
|
|
84058
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
84059
|
+
relative_humidity?: number | undefined
|
|
84060
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
84061
|
+
noise_level_decibels?: number | undefined
|
|
84062
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
84063
|
+
noise_level_nrs?: number | undefined
|
|
84064
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
84065
|
+
co2_ppm?: number | undefined
|
|
84066
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
84067
|
+
co_ppm?: number | undefined
|
|
84068
|
+
/** Air quality index, if the device measures it. */
|
|
84069
|
+
air_quality_index?: number | undefined
|
|
84070
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
84071
|
+
mold_risk_level?: string | undefined
|
|
84072
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
84073
|
+
is_occupied?: boolean | undefined
|
|
84074
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
84075
|
+
occupant_count?: number | undefined
|
|
84076
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
84077
|
+
is_smoking_detected?: boolean | undefined
|
|
84078
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
84079
|
+
named_sensors?:
|
|
84080
|
+
| {
|
|
84081
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
84082
|
+
sensor_name: string
|
|
84083
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
84084
|
+
display_name: string
|
|
84085
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
84086
|
+
temperature_celsius?: number | undefined
|
|
84087
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
84088
|
+
temperature_fahrenheit?: number | undefined
|
|
84089
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
84090
|
+
relative_humidity?: number | undefined
|
|
84091
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
84092
|
+
noise_level_decibels?: number | undefined
|
|
84093
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
84094
|
+
noise_level_nrs?: number | undefined
|
|
84095
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
84096
|
+
co2_ppm?: number | undefined
|
|
84097
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
84098
|
+
co_ppm?: number | undefined
|
|
84099
|
+
/** Air quality index, if the device measures it. */
|
|
84100
|
+
air_quality_index?: number | undefined
|
|
84101
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
84102
|
+
mold_risk_level?: string | undefined
|
|
84103
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
84104
|
+
is_occupied?: boolean | undefined
|
|
84105
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
84106
|
+
occupant_count?: number | undefined
|
|
84107
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
84108
|
+
is_smoking_detected?: boolean | undefined
|
|
84109
|
+
}[]
|
|
84110
|
+
| undefined
|
|
84055
84111
|
/** Indicates whether the device supports remote unlocking. */
|
|
84056
84112
|
can_remotely_unlock?: boolean | undefined
|
|
84057
84113
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -84284,58 +84340,9 @@ export type Routes = {
|
|
|
84284
84340
|
* @deprecated use offline_access_codes_enabled*/
|
|
84285
84341
|
supports_offline_access_codes?: boolean | undefined
|
|
84286
84342
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
84287
|
-
noise_level_decibels?:
|
|
84343
|
+
noise_level_decibels?: number | undefined
|
|
84288
84344
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
84289
84345
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
84290
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
84291
|
-
noise_level_nrs?: (number | null) | undefined
|
|
84292
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
84293
|
-
co2_ppm?: (number | null) | undefined
|
|
84294
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
84295
|
-
co_ppm?: (number | null) | undefined
|
|
84296
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
84297
|
-
air_quality_index?: (number | null) | undefined
|
|
84298
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
84299
|
-
mold_risk_level?: (string | null) | undefined
|
|
84300
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
84301
|
-
is_occupied?: (boolean | null) | undefined
|
|
84302
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
84303
|
-
occupant_count?: (number | null) | undefined
|
|
84304
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
84305
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
84306
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
84307
|
-
named_sensors?:
|
|
84308
|
-
| {
|
|
84309
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
84310
|
-
sensor_name: string
|
|
84311
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
84312
|
-
display_name: string
|
|
84313
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
84314
|
-
temperature_celsius?: (number | null) | undefined
|
|
84315
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
84316
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
84317
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
84318
|
-
relative_humidity?: (number | null) | undefined
|
|
84319
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
84320
|
-
noise_level_decibels?: (number | null) | undefined
|
|
84321
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
84322
|
-
noise_level_nrs?: (number | null) | undefined
|
|
84323
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
84324
|
-
co2_ppm?: (number | null) | undefined
|
|
84325
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
84326
|
-
co_ppm?: (number | null) | undefined
|
|
84327
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
84328
|
-
air_quality_index?: (number | null) | undefined
|
|
84329
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
84330
|
-
mold_risk_level?: (string | null) | undefined
|
|
84331
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
84332
|
-
is_occupied?: (boolean | null) | undefined
|
|
84333
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
84334
|
-
occupant_count?: (number | null) | undefined
|
|
84335
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
84336
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
84337
|
-
}[]
|
|
84338
|
-
| undefined
|
|
84339
84346
|
} & {
|
|
84340
84347
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
84341
84348
|
assa_abloy_credential_service_metadata?:
|
|
@@ -85393,11 +85400,11 @@ export type Routes = {
|
|
|
85393
85400
|
| undefined
|
|
85394
85401
|
} & {
|
|
85395
85402
|
/** Reported temperature in °F. */
|
|
85396
|
-
temperature_fahrenheit?:
|
|
85403
|
+
temperature_fahrenheit?: number | undefined
|
|
85397
85404
|
/** Reported temperature in °C. */
|
|
85398
|
-
temperature_celsius?:
|
|
85405
|
+
temperature_celsius?: number | undefined
|
|
85399
85406
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
85400
|
-
relative_humidity?:
|
|
85407
|
+
relative_humidity?: number | undefined
|
|
85401
85408
|
/** HVAC mode settings that the thermostat supports. */
|
|
85402
85409
|
available_hvac_mode_settings?:
|
|
85403
85410
|
('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined
|
|
@@ -86210,6 +86217,63 @@ export type Routes = {
|
|
|
86210
86217
|
image_url?: string | undefined
|
|
86211
86218
|
}
|
|
86212
86219
|
| undefined
|
|
86220
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
86221
|
+
temperature_celsius?: number | undefined
|
|
86222
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
86223
|
+
temperature_fahrenheit?: number | undefined
|
|
86224
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
86225
|
+
relative_humidity?: number | undefined
|
|
86226
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
86227
|
+
noise_level_decibels?: number | undefined
|
|
86228
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
86229
|
+
noise_level_nrs?: number | undefined
|
|
86230
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
86231
|
+
co2_ppm?: number | undefined
|
|
86232
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
86233
|
+
co_ppm?: number | undefined
|
|
86234
|
+
/** Air quality index, if the device measures it. */
|
|
86235
|
+
air_quality_index?: number | undefined
|
|
86236
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
86237
|
+
mold_risk_level?: string | undefined
|
|
86238
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
86239
|
+
is_occupied?: boolean | undefined
|
|
86240
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
86241
|
+
occupant_count?: number | undefined
|
|
86242
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
86243
|
+
is_smoking_detected?: boolean | undefined
|
|
86244
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
86245
|
+
named_sensors?:
|
|
86246
|
+
| {
|
|
86247
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
86248
|
+
sensor_name: string
|
|
86249
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
86250
|
+
display_name: string
|
|
86251
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
86252
|
+
temperature_celsius?: number | undefined
|
|
86253
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
86254
|
+
temperature_fahrenheit?: number | undefined
|
|
86255
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
86256
|
+
relative_humidity?: number | undefined
|
|
86257
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
86258
|
+
noise_level_decibels?: number | undefined
|
|
86259
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
86260
|
+
noise_level_nrs?: number | undefined
|
|
86261
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
86262
|
+
co2_ppm?: number | undefined
|
|
86263
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
86264
|
+
co_ppm?: number | undefined
|
|
86265
|
+
/** Air quality index, if the device measures it. */
|
|
86266
|
+
air_quality_index?: number | undefined
|
|
86267
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
86268
|
+
mold_risk_level?: string | undefined
|
|
86269
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
86270
|
+
is_occupied?: boolean | undefined
|
|
86271
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
86272
|
+
occupant_count?: number | undefined
|
|
86273
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
86274
|
+
is_smoking_detected?: boolean | undefined
|
|
86275
|
+
}[]
|
|
86276
|
+
| undefined
|
|
86213
86277
|
/** Indicates whether the device supports remote unlocking. */
|
|
86214
86278
|
can_remotely_unlock?: boolean | undefined
|
|
86215
86279
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -96693,58 +96757,9 @@ export type Routes = {
|
|
|
96693
96757
|
* @deprecated use offline_access_codes_enabled*/
|
|
96694
96758
|
supports_offline_access_codes?: boolean | undefined
|
|
96695
96759
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
96696
|
-
noise_level_decibels?:
|
|
96760
|
+
noise_level_decibels?: number | undefined
|
|
96697
96761
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
96698
96762
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
96699
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
96700
|
-
noise_level_nrs?: (number | null) | undefined
|
|
96701
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
96702
|
-
co2_ppm?: (number | null) | undefined
|
|
96703
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
96704
|
-
co_ppm?: (number | null) | undefined
|
|
96705
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
96706
|
-
air_quality_index?: (number | null) | undefined
|
|
96707
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
96708
|
-
mold_risk_level?: (string | null) | undefined
|
|
96709
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
96710
|
-
is_occupied?: (boolean | null) | undefined
|
|
96711
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
96712
|
-
occupant_count?: (number | null) | undefined
|
|
96713
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
96714
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
96715
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
96716
|
-
named_sensors?:
|
|
96717
|
-
| {
|
|
96718
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
96719
|
-
sensor_name: string
|
|
96720
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
96721
|
-
display_name: string
|
|
96722
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
96723
|
-
temperature_celsius?: (number | null) | undefined
|
|
96724
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
96725
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
96726
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
96727
|
-
relative_humidity?: (number | null) | undefined
|
|
96728
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
96729
|
-
noise_level_decibels?: (number | null) | undefined
|
|
96730
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
96731
|
-
noise_level_nrs?: (number | null) | undefined
|
|
96732
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
96733
|
-
co2_ppm?: (number | null) | undefined
|
|
96734
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
96735
|
-
co_ppm?: (number | null) | undefined
|
|
96736
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
96737
|
-
air_quality_index?: (number | null) | undefined
|
|
96738
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
96739
|
-
mold_risk_level?: (string | null) | undefined
|
|
96740
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
96741
|
-
is_occupied?: (boolean | null) | undefined
|
|
96742
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
96743
|
-
occupant_count?: (number | null) | undefined
|
|
96744
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
96745
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
96746
|
-
}[]
|
|
96747
|
-
| undefined
|
|
96748
96763
|
} & {
|
|
96749
96764
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
96750
96765
|
assa_abloy_credential_service_metadata?:
|
|
@@ -97802,11 +97817,11 @@ export type Routes = {
|
|
|
97802
97817
|
| undefined
|
|
97803
97818
|
} & {
|
|
97804
97819
|
/** Reported temperature in °F. */
|
|
97805
|
-
temperature_fahrenheit?:
|
|
97820
|
+
temperature_fahrenheit?: number | undefined
|
|
97806
97821
|
/** Reported temperature in °C. */
|
|
97807
|
-
temperature_celsius?:
|
|
97822
|
+
temperature_celsius?: number | undefined
|
|
97808
97823
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
97809
|
-
relative_humidity?:
|
|
97824
|
+
relative_humidity?: number | undefined
|
|
97810
97825
|
/** HVAC mode settings that the thermostat supports. */
|
|
97811
97826
|
available_hvac_mode_settings?:
|
|
97812
97827
|
('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined
|
|
@@ -98619,6 +98634,63 @@ export type Routes = {
|
|
|
98619
98634
|
image_url?: string | undefined
|
|
98620
98635
|
}
|
|
98621
98636
|
| undefined
|
|
98637
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
98638
|
+
temperature_celsius?: number | undefined
|
|
98639
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
98640
|
+
temperature_fahrenheit?: number | undefined
|
|
98641
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
98642
|
+
relative_humidity?: number | undefined
|
|
98643
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
98644
|
+
noise_level_decibels?: number | undefined
|
|
98645
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
98646
|
+
noise_level_nrs?: number | undefined
|
|
98647
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
98648
|
+
co2_ppm?: number | undefined
|
|
98649
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
98650
|
+
co_ppm?: number | undefined
|
|
98651
|
+
/** Air quality index, if the device measures it. */
|
|
98652
|
+
air_quality_index?: number | undefined
|
|
98653
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
98654
|
+
mold_risk_level?: string | undefined
|
|
98655
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
98656
|
+
is_occupied?: boolean | undefined
|
|
98657
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
98658
|
+
occupant_count?: number | undefined
|
|
98659
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
98660
|
+
is_smoking_detected?: boolean | undefined
|
|
98661
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
98662
|
+
named_sensors?:
|
|
98663
|
+
| {
|
|
98664
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
98665
|
+
sensor_name: string
|
|
98666
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
98667
|
+
display_name: string
|
|
98668
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
98669
|
+
temperature_celsius?: number | undefined
|
|
98670
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
98671
|
+
temperature_fahrenheit?: number | undefined
|
|
98672
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
98673
|
+
relative_humidity?: number | undefined
|
|
98674
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
98675
|
+
noise_level_decibels?: number | undefined
|
|
98676
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
98677
|
+
noise_level_nrs?: number | undefined
|
|
98678
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
98679
|
+
co2_ppm?: number | undefined
|
|
98680
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
98681
|
+
co_ppm?: number | undefined
|
|
98682
|
+
/** Air quality index, if the device measures it. */
|
|
98683
|
+
air_quality_index?: number | undefined
|
|
98684
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
98685
|
+
mold_risk_level?: string | undefined
|
|
98686
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
98687
|
+
is_occupied?: boolean | undefined
|
|
98688
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
98689
|
+
occupant_count?: number | undefined
|
|
98690
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
98691
|
+
is_smoking_detected?: boolean | undefined
|
|
98692
|
+
}[]
|
|
98693
|
+
| undefined
|
|
98622
98694
|
/** Indicates whether the device supports remote unlocking. */
|
|
98623
98695
|
can_remotely_unlock?: boolean | undefined
|
|
98624
98696
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -98851,58 +98923,9 @@ export type Routes = {
|
|
|
98851
98923
|
* @deprecated use offline_access_codes_enabled*/
|
|
98852
98924
|
supports_offline_access_codes?: boolean | undefined
|
|
98853
98925
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
98854
|
-
noise_level_decibels?:
|
|
98926
|
+
noise_level_decibels?: number | undefined
|
|
98855
98927
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
98856
98928
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
98857
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
98858
|
-
noise_level_nrs?: (number | null) | undefined
|
|
98859
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
98860
|
-
co2_ppm?: (number | null) | undefined
|
|
98861
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
98862
|
-
co_ppm?: (number | null) | undefined
|
|
98863
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
98864
|
-
air_quality_index?: (number | null) | undefined
|
|
98865
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
98866
|
-
mold_risk_level?: (string | null) | undefined
|
|
98867
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
98868
|
-
is_occupied?: (boolean | null) | undefined
|
|
98869
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
98870
|
-
occupant_count?: (number | null) | undefined
|
|
98871
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
98872
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
98873
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
98874
|
-
named_sensors?:
|
|
98875
|
-
| {
|
|
98876
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
98877
|
-
sensor_name: string
|
|
98878
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
98879
|
-
display_name: string
|
|
98880
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
98881
|
-
temperature_celsius?: (number | null) | undefined
|
|
98882
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
98883
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
98884
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
98885
|
-
relative_humidity?: (number | null) | undefined
|
|
98886
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
98887
|
-
noise_level_decibels?: (number | null) | undefined
|
|
98888
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
98889
|
-
noise_level_nrs?: (number | null) | undefined
|
|
98890
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
98891
|
-
co2_ppm?: (number | null) | undefined
|
|
98892
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
98893
|
-
co_ppm?: (number | null) | undefined
|
|
98894
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
98895
|
-
air_quality_index?: (number | null) | undefined
|
|
98896
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
98897
|
-
mold_risk_level?: (string | null) | undefined
|
|
98898
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
98899
|
-
is_occupied?: (boolean | null) | undefined
|
|
98900
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
98901
|
-
occupant_count?: (number | null) | undefined
|
|
98902
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
98903
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
98904
|
-
}[]
|
|
98905
|
-
| undefined
|
|
98906
98929
|
} & {
|
|
98907
98930
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
98908
98931
|
assa_abloy_credential_service_metadata?:
|
|
@@ -99960,11 +99983,11 @@ export type Routes = {
|
|
|
99960
99983
|
| undefined
|
|
99961
99984
|
} & {
|
|
99962
99985
|
/** Reported temperature in °F. */
|
|
99963
|
-
temperature_fahrenheit?:
|
|
99986
|
+
temperature_fahrenheit?: number | undefined
|
|
99964
99987
|
/** Reported temperature in °C. */
|
|
99965
|
-
temperature_celsius?:
|
|
99988
|
+
temperature_celsius?: number | undefined
|
|
99966
99989
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
99967
|
-
relative_humidity?:
|
|
99990
|
+
relative_humidity?: number | undefined
|
|
99968
99991
|
/** HVAC mode settings that the thermostat supports. */
|
|
99969
99992
|
available_hvac_mode_settings?:
|
|
99970
99993
|
('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined
|
|
@@ -100777,6 +100800,63 @@ export type Routes = {
|
|
|
100777
100800
|
image_url?: string | undefined
|
|
100778
100801
|
}
|
|
100779
100802
|
| undefined
|
|
100803
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
100804
|
+
temperature_celsius?: number | undefined
|
|
100805
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
100806
|
+
temperature_fahrenheit?: number | undefined
|
|
100807
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
100808
|
+
relative_humidity?: number | undefined
|
|
100809
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
100810
|
+
noise_level_decibels?: number | undefined
|
|
100811
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
100812
|
+
noise_level_nrs?: number | undefined
|
|
100813
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
100814
|
+
co2_ppm?: number | undefined
|
|
100815
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
100816
|
+
co_ppm?: number | undefined
|
|
100817
|
+
/** Air quality index, if the device measures it. */
|
|
100818
|
+
air_quality_index?: number | undefined
|
|
100819
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
100820
|
+
mold_risk_level?: string | undefined
|
|
100821
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
100822
|
+
is_occupied?: boolean | undefined
|
|
100823
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
100824
|
+
occupant_count?: number | undefined
|
|
100825
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
100826
|
+
is_smoking_detected?: boolean | undefined
|
|
100827
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
100828
|
+
named_sensors?:
|
|
100829
|
+
| {
|
|
100830
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
100831
|
+
sensor_name: string
|
|
100832
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
100833
|
+
display_name: string
|
|
100834
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
100835
|
+
temperature_celsius?: number | undefined
|
|
100836
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
100837
|
+
temperature_fahrenheit?: number | undefined
|
|
100838
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
100839
|
+
relative_humidity?: number | undefined
|
|
100840
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
100841
|
+
noise_level_decibels?: number | undefined
|
|
100842
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
100843
|
+
noise_level_nrs?: number | undefined
|
|
100844
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
100845
|
+
co2_ppm?: number | undefined
|
|
100846
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
100847
|
+
co_ppm?: number | undefined
|
|
100848
|
+
/** Air quality index, if the device measures it. */
|
|
100849
|
+
air_quality_index?: number | undefined
|
|
100850
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
100851
|
+
mold_risk_level?: string | undefined
|
|
100852
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
100853
|
+
is_occupied?: boolean | undefined
|
|
100854
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
100855
|
+
occupant_count?: number | undefined
|
|
100856
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
100857
|
+
is_smoking_detected?: boolean | undefined
|
|
100858
|
+
}[]
|
|
100859
|
+
| undefined
|
|
100780
100860
|
/** Indicates whether the device supports remote unlocking. */
|
|
100781
100861
|
can_remotely_unlock?: boolean | undefined
|
|
100782
100862
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -128614,58 +128694,9 @@ export type Routes = {
|
|
|
128614
128694
|
* @deprecated use offline_access_codes_enabled*/
|
|
128615
128695
|
supports_offline_access_codes?: boolean | undefined
|
|
128616
128696
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
128617
|
-
noise_level_decibels?:
|
|
128697
|
+
noise_level_decibels?: number | undefined
|
|
128618
128698
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
128619
128699
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
128620
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
128621
|
-
noise_level_nrs?: (number | null) | undefined
|
|
128622
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
128623
|
-
co2_ppm?: (number | null) | undefined
|
|
128624
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
128625
|
-
co_ppm?: (number | null) | undefined
|
|
128626
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
128627
|
-
air_quality_index?: (number | null) | undefined
|
|
128628
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
128629
|
-
mold_risk_level?: (string | null) | undefined
|
|
128630
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
128631
|
-
is_occupied?: (boolean | null) | undefined
|
|
128632
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
128633
|
-
occupant_count?: (number | null) | undefined
|
|
128634
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
128635
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
128636
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
128637
|
-
named_sensors?:
|
|
128638
|
-
| {
|
|
128639
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
128640
|
-
sensor_name: string
|
|
128641
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
128642
|
-
display_name: string
|
|
128643
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
128644
|
-
temperature_celsius?: (number | null) | undefined
|
|
128645
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
128646
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
128647
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
128648
|
-
relative_humidity?: (number | null) | undefined
|
|
128649
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
128650
|
-
noise_level_decibels?: (number | null) | undefined
|
|
128651
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
128652
|
-
noise_level_nrs?: (number | null) | undefined
|
|
128653
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
128654
|
-
co2_ppm?: (number | null) | undefined
|
|
128655
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
128656
|
-
co_ppm?: (number | null) | undefined
|
|
128657
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
128658
|
-
air_quality_index?: (number | null) | undefined
|
|
128659
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
128660
|
-
mold_risk_level?: (string | null) | undefined
|
|
128661
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
128662
|
-
is_occupied?: (boolean | null) | undefined
|
|
128663
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
128664
|
-
occupant_count?: (number | null) | undefined
|
|
128665
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
128666
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
128667
|
-
}[]
|
|
128668
|
-
| undefined
|
|
128669
128700
|
} & {
|
|
128670
128701
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
128671
128702
|
assa_abloy_credential_service_metadata?:
|
|
@@ -129758,11 +129789,11 @@ export type Routes = {
|
|
|
129758
129789
|
| undefined
|
|
129759
129790
|
} & {
|
|
129760
129791
|
/** Reported temperature in °F. */
|
|
129761
|
-
temperature_fahrenheit?:
|
|
129792
|
+
temperature_fahrenheit?: number | undefined
|
|
129762
129793
|
/** Reported temperature in °C. */
|
|
129763
|
-
temperature_celsius?:
|
|
129794
|
+
temperature_celsius?: number | undefined
|
|
129764
129795
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
129765
|
-
relative_humidity?:
|
|
129796
|
+
relative_humidity?: number | undefined
|
|
129766
129797
|
/** HVAC mode settings that the thermostat supports. */
|
|
129767
129798
|
available_hvac_mode_settings?:
|
|
129768
129799
|
| ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[]
|
|
@@ -130597,6 +130628,63 @@ export type Routes = {
|
|
|
130597
130628
|
image_url?: string | undefined
|
|
130598
130629
|
}
|
|
130599
130630
|
| undefined
|
|
130631
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
130632
|
+
temperature_celsius?: number | undefined
|
|
130633
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
130634
|
+
temperature_fahrenheit?: number | undefined
|
|
130635
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
130636
|
+
relative_humidity?: number | undefined
|
|
130637
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
130638
|
+
noise_level_decibels?: number | undefined
|
|
130639
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
130640
|
+
noise_level_nrs?: number | undefined
|
|
130641
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
130642
|
+
co2_ppm?: number | undefined
|
|
130643
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
130644
|
+
co_ppm?: number | undefined
|
|
130645
|
+
/** Air quality index, if the device measures it. */
|
|
130646
|
+
air_quality_index?: number | undefined
|
|
130647
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
130648
|
+
mold_risk_level?: string | undefined
|
|
130649
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
130650
|
+
is_occupied?: boolean | undefined
|
|
130651
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
130652
|
+
occupant_count?: number | undefined
|
|
130653
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
130654
|
+
is_smoking_detected?: boolean | undefined
|
|
130655
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
130656
|
+
named_sensors?:
|
|
130657
|
+
| {
|
|
130658
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
130659
|
+
sensor_name: string
|
|
130660
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
130661
|
+
display_name: string
|
|
130662
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
130663
|
+
temperature_celsius?: number | undefined
|
|
130664
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
130665
|
+
temperature_fahrenheit?: number | undefined
|
|
130666
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
130667
|
+
relative_humidity?: number | undefined
|
|
130668
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
130669
|
+
noise_level_decibels?: number | undefined
|
|
130670
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
130671
|
+
noise_level_nrs?: number | undefined
|
|
130672
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
130673
|
+
co2_ppm?: number | undefined
|
|
130674
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
130675
|
+
co_ppm?: number | undefined
|
|
130676
|
+
/** Air quality index, if the device measures it. */
|
|
130677
|
+
air_quality_index?: number | undefined
|
|
130678
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
130679
|
+
mold_risk_level?: string | undefined
|
|
130680
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
130681
|
+
is_occupied?: boolean | undefined
|
|
130682
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
130683
|
+
occupant_count?: number | undefined
|
|
130684
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
130685
|
+
is_smoking_detected?: boolean | undefined
|
|
130686
|
+
}[]
|
|
130687
|
+
| undefined
|
|
130600
130688
|
/** Indicates whether the device supports remote unlocking. */
|
|
130601
130689
|
can_remotely_unlock?: boolean | undefined
|
|
130602
130690
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -162730,58 +162818,9 @@ export type Routes = {
|
|
|
162730
162818
|
* @deprecated use offline_access_codes_enabled*/
|
|
162731
162819
|
supports_offline_access_codes?: boolean | undefined
|
|
162732
162820
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
162733
|
-
noise_level_decibels?:
|
|
162821
|
+
noise_level_decibels?: number | undefined
|
|
162734
162822
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
162735
162823
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
162736
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
162737
|
-
noise_level_nrs?: (number | null) | undefined
|
|
162738
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
162739
|
-
co2_ppm?: (number | null) | undefined
|
|
162740
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
162741
|
-
co_ppm?: (number | null) | undefined
|
|
162742
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
162743
|
-
air_quality_index?: (number | null) | undefined
|
|
162744
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
162745
|
-
mold_risk_level?: (string | null) | undefined
|
|
162746
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
162747
|
-
is_occupied?: (boolean | null) | undefined
|
|
162748
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
162749
|
-
occupant_count?: (number | null) | undefined
|
|
162750
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
162751
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
162752
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
162753
|
-
named_sensors?:
|
|
162754
|
-
| {
|
|
162755
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
162756
|
-
sensor_name: string
|
|
162757
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
162758
|
-
display_name: string
|
|
162759
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
162760
|
-
temperature_celsius?: (number | null) | undefined
|
|
162761
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
162762
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
162763
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
162764
|
-
relative_humidity?: (number | null) | undefined
|
|
162765
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
162766
|
-
noise_level_decibels?: (number | null) | undefined
|
|
162767
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
162768
|
-
noise_level_nrs?: (number | null) | undefined
|
|
162769
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
162770
|
-
co2_ppm?: (number | null) | undefined
|
|
162771
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
162772
|
-
co_ppm?: (number | null) | undefined
|
|
162773
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
162774
|
-
air_quality_index?: (number | null) | undefined
|
|
162775
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
162776
|
-
mold_risk_level?: (string | null) | undefined
|
|
162777
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
162778
|
-
is_occupied?: (boolean | null) | undefined
|
|
162779
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
162780
|
-
occupant_count?: (number | null) | undefined
|
|
162781
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
162782
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
162783
|
-
}[]
|
|
162784
|
-
| undefined
|
|
162785
162824
|
} & {
|
|
162786
162825
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
162787
162826
|
assa_abloy_credential_service_metadata?:
|
|
@@ -163839,11 +163878,11 @@ export type Routes = {
|
|
|
163839
163878
|
| undefined
|
|
163840
163879
|
} & {
|
|
163841
163880
|
/** Reported temperature in °F. */
|
|
163842
|
-
temperature_fahrenheit?:
|
|
163881
|
+
temperature_fahrenheit?: number | undefined
|
|
163843
163882
|
/** Reported temperature in °C. */
|
|
163844
|
-
temperature_celsius?:
|
|
163883
|
+
temperature_celsius?: number | undefined
|
|
163845
163884
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
163846
|
-
relative_humidity?:
|
|
163885
|
+
relative_humidity?: number | undefined
|
|
163847
163886
|
/** HVAC mode settings that the thermostat supports. */
|
|
163848
163887
|
available_hvac_mode_settings?:
|
|
163849
163888
|
('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined
|
|
@@ -164656,6 +164695,63 @@ export type Routes = {
|
|
|
164656
164695
|
image_url?: string | undefined
|
|
164657
164696
|
}
|
|
164658
164697
|
| undefined
|
|
164698
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
164699
|
+
temperature_celsius?: number | undefined
|
|
164700
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
164701
|
+
temperature_fahrenheit?: number | undefined
|
|
164702
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
164703
|
+
relative_humidity?: number | undefined
|
|
164704
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
164705
|
+
noise_level_decibels?: number | undefined
|
|
164706
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
164707
|
+
noise_level_nrs?: number | undefined
|
|
164708
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
164709
|
+
co2_ppm?: number | undefined
|
|
164710
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
164711
|
+
co_ppm?: number | undefined
|
|
164712
|
+
/** Air quality index, if the device measures it. */
|
|
164713
|
+
air_quality_index?: number | undefined
|
|
164714
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
164715
|
+
mold_risk_level?: string | undefined
|
|
164716
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
164717
|
+
is_occupied?: boolean | undefined
|
|
164718
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
164719
|
+
occupant_count?: number | undefined
|
|
164720
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
164721
|
+
is_smoking_detected?: boolean | undefined
|
|
164722
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
164723
|
+
named_sensors?:
|
|
164724
|
+
| {
|
|
164725
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
164726
|
+
sensor_name: string
|
|
164727
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
164728
|
+
display_name: string
|
|
164729
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
164730
|
+
temperature_celsius?: number | undefined
|
|
164731
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
164732
|
+
temperature_fahrenheit?: number | undefined
|
|
164733
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
164734
|
+
relative_humidity?: number | undefined
|
|
164735
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
164736
|
+
noise_level_decibels?: number | undefined
|
|
164737
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
164738
|
+
noise_level_nrs?: number | undefined
|
|
164739
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
164740
|
+
co2_ppm?: number | undefined
|
|
164741
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
164742
|
+
co_ppm?: number | undefined
|
|
164743
|
+
/** Air quality index, if the device measures it. */
|
|
164744
|
+
air_quality_index?: number | undefined
|
|
164745
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
164746
|
+
mold_risk_level?: string | undefined
|
|
164747
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
164748
|
+
is_occupied?: boolean | undefined
|
|
164749
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
164750
|
+
occupant_count?: number | undefined
|
|
164751
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
164752
|
+
is_smoking_detected?: boolean | undefined
|
|
164753
|
+
}[]
|
|
164754
|
+
| undefined
|
|
164659
164755
|
/** Indicates whether the device supports remote unlocking. */
|
|
164660
164756
|
can_remotely_unlock?: boolean | undefined
|
|
164661
164757
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -170045,58 +170141,9 @@ export type Routes = {
|
|
|
170045
170141
|
* @deprecated use offline_access_codes_enabled*/
|
|
170046
170142
|
supports_offline_access_codes?: boolean | undefined
|
|
170047
170143
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
170048
|
-
noise_level_decibels?:
|
|
170144
|
+
noise_level_decibels?: number | undefined
|
|
170049
170145
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
170050
170146
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
170051
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
170052
|
-
noise_level_nrs?: (number | null) | undefined
|
|
170053
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
170054
|
-
co2_ppm?: (number | null) | undefined
|
|
170055
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
170056
|
-
co_ppm?: (number | null) | undefined
|
|
170057
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
170058
|
-
air_quality_index?: (number | null) | undefined
|
|
170059
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
170060
|
-
mold_risk_level?: (string | null) | undefined
|
|
170061
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
170062
|
-
is_occupied?: (boolean | null) | undefined
|
|
170063
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
170064
|
-
occupant_count?: (number | null) | undefined
|
|
170065
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
170066
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
170067
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
170068
|
-
named_sensors?:
|
|
170069
|
-
| {
|
|
170070
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
170071
|
-
sensor_name: string
|
|
170072
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
170073
|
-
display_name: string
|
|
170074
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
170075
|
-
temperature_celsius?: (number | null) | undefined
|
|
170076
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
170077
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
170078
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
170079
|
-
relative_humidity?: (number | null) | undefined
|
|
170080
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
170081
|
-
noise_level_decibels?: (number | null) | undefined
|
|
170082
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
170083
|
-
noise_level_nrs?: (number | null) | undefined
|
|
170084
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
170085
|
-
co2_ppm?: (number | null) | undefined
|
|
170086
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
170087
|
-
co_ppm?: (number | null) | undefined
|
|
170088
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
170089
|
-
air_quality_index?: (number | null) | undefined
|
|
170090
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
170091
|
-
mold_risk_level?: (string | null) | undefined
|
|
170092
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
170093
|
-
is_occupied?: (boolean | null) | undefined
|
|
170094
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
170095
|
-
occupant_count?: (number | null) | undefined
|
|
170096
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
170097
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
170098
|
-
}[]
|
|
170099
|
-
| undefined
|
|
170100
170147
|
} & {
|
|
170101
170148
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
170102
170149
|
assa_abloy_credential_service_metadata?:
|
|
@@ -171154,11 +171201,11 @@ export type Routes = {
|
|
|
171154
171201
|
| undefined
|
|
171155
171202
|
} & {
|
|
171156
171203
|
/** Reported temperature in °F. */
|
|
171157
|
-
temperature_fahrenheit?:
|
|
171204
|
+
temperature_fahrenheit?: number | undefined
|
|
171158
171205
|
/** Reported temperature in °C. */
|
|
171159
|
-
temperature_celsius?:
|
|
171206
|
+
temperature_celsius?: number | undefined
|
|
171160
171207
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
171161
|
-
relative_humidity?:
|
|
171208
|
+
relative_humidity?: number | undefined
|
|
171162
171209
|
/** HVAC mode settings that the thermostat supports. */
|
|
171163
171210
|
available_hvac_mode_settings?:
|
|
171164
171211
|
('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined
|
|
@@ -171971,6 +172018,63 @@ export type Routes = {
|
|
|
171971
172018
|
image_url?: string | undefined
|
|
171972
172019
|
}
|
|
171973
172020
|
| undefined
|
|
172021
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
172022
|
+
temperature_celsius?: number | undefined
|
|
172023
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
172024
|
+
temperature_fahrenheit?: number | undefined
|
|
172025
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
172026
|
+
relative_humidity?: number | undefined
|
|
172027
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
172028
|
+
noise_level_decibels?: number | undefined
|
|
172029
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
172030
|
+
noise_level_nrs?: number | undefined
|
|
172031
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
172032
|
+
co2_ppm?: number | undefined
|
|
172033
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
172034
|
+
co_ppm?: number | undefined
|
|
172035
|
+
/** Air quality index, if the device measures it. */
|
|
172036
|
+
air_quality_index?: number | undefined
|
|
172037
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
172038
|
+
mold_risk_level?: string | undefined
|
|
172039
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
172040
|
+
is_occupied?: boolean | undefined
|
|
172041
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
172042
|
+
occupant_count?: number | undefined
|
|
172043
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
172044
|
+
is_smoking_detected?: boolean | undefined
|
|
172045
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
172046
|
+
named_sensors?:
|
|
172047
|
+
| {
|
|
172048
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
172049
|
+
sensor_name: string
|
|
172050
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
172051
|
+
display_name: string
|
|
172052
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
172053
|
+
temperature_celsius?: number | undefined
|
|
172054
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
172055
|
+
temperature_fahrenheit?: number | undefined
|
|
172056
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
172057
|
+
relative_humidity?: number | undefined
|
|
172058
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
172059
|
+
noise_level_decibels?: number | undefined
|
|
172060
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
172061
|
+
noise_level_nrs?: number | undefined
|
|
172062
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
172063
|
+
co2_ppm?: number | undefined
|
|
172064
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
172065
|
+
co_ppm?: number | undefined
|
|
172066
|
+
/** Air quality index, if the device measures it. */
|
|
172067
|
+
air_quality_index?: number | undefined
|
|
172068
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
172069
|
+
mold_risk_level?: string | undefined
|
|
172070
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
172071
|
+
is_occupied?: boolean | undefined
|
|
172072
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
172073
|
+
occupant_count?: number | undefined
|
|
172074
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
172075
|
+
is_smoking_detected?: boolean | undefined
|
|
172076
|
+
}[]
|
|
172077
|
+
| undefined
|
|
171974
172078
|
/** Indicates whether the device supports remote unlocking. */
|
|
171975
172079
|
can_remotely_unlock?: boolean | undefined
|
|
171976
172080
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -172203,58 +172307,9 @@ export type Routes = {
|
|
|
172203
172307
|
* @deprecated use offline_access_codes_enabled*/
|
|
172204
172308
|
supports_offline_access_codes?: boolean | undefined
|
|
172205
172309
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
172206
|
-
noise_level_decibels?:
|
|
172310
|
+
noise_level_decibels?: number | undefined
|
|
172207
172311
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
172208
172312
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
172209
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
172210
|
-
noise_level_nrs?: (number | null) | undefined
|
|
172211
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
172212
|
-
co2_ppm?: (number | null) | undefined
|
|
172213
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
172214
|
-
co_ppm?: (number | null) | undefined
|
|
172215
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
172216
|
-
air_quality_index?: (number | null) | undefined
|
|
172217
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
172218
|
-
mold_risk_level?: (string | null) | undefined
|
|
172219
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
172220
|
-
is_occupied?: (boolean | null) | undefined
|
|
172221
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
172222
|
-
occupant_count?: (number | null) | undefined
|
|
172223
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
172224
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
172225
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
172226
|
-
named_sensors?:
|
|
172227
|
-
| {
|
|
172228
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
172229
|
-
sensor_name: string
|
|
172230
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
172231
|
-
display_name: string
|
|
172232
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
172233
|
-
temperature_celsius?: (number | null) | undefined
|
|
172234
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
172235
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
172236
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
172237
|
-
relative_humidity?: (number | null) | undefined
|
|
172238
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
172239
|
-
noise_level_decibels?: (number | null) | undefined
|
|
172240
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
172241
|
-
noise_level_nrs?: (number | null) | undefined
|
|
172242
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
172243
|
-
co2_ppm?: (number | null) | undefined
|
|
172244
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
172245
|
-
co_ppm?: (number | null) | undefined
|
|
172246
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
172247
|
-
air_quality_index?: (number | null) | undefined
|
|
172248
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
172249
|
-
mold_risk_level?: (string | null) | undefined
|
|
172250
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
172251
|
-
is_occupied?: (boolean | null) | undefined
|
|
172252
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
172253
|
-
occupant_count?: (number | null) | undefined
|
|
172254
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
172255
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
172256
|
-
}[]
|
|
172257
|
-
| undefined
|
|
172258
172313
|
} & {
|
|
172259
172314
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
172260
172315
|
assa_abloy_credential_service_metadata?:
|
|
@@ -173312,11 +173367,11 @@ export type Routes = {
|
|
|
173312
173367
|
| undefined
|
|
173313
173368
|
} & {
|
|
173314
173369
|
/** Reported temperature in °F. */
|
|
173315
|
-
temperature_fahrenheit?:
|
|
173370
|
+
temperature_fahrenheit?: number | undefined
|
|
173316
173371
|
/** Reported temperature in °C. */
|
|
173317
|
-
temperature_celsius?:
|
|
173372
|
+
temperature_celsius?: number | undefined
|
|
173318
173373
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
173319
|
-
relative_humidity?:
|
|
173374
|
+
relative_humidity?: number | undefined
|
|
173320
173375
|
/** HVAC mode settings that the thermostat supports. */
|
|
173321
173376
|
available_hvac_mode_settings?:
|
|
173322
173377
|
('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined
|
|
@@ -174129,6 +174184,63 @@ export type Routes = {
|
|
|
174129
174184
|
image_url?: string | undefined
|
|
174130
174185
|
}
|
|
174131
174186
|
| undefined
|
|
174187
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
174188
|
+
temperature_celsius?: number | undefined
|
|
174189
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
174190
|
+
temperature_fahrenheit?: number | undefined
|
|
174191
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
174192
|
+
relative_humidity?: number | undefined
|
|
174193
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
174194
|
+
noise_level_decibels?: number | undefined
|
|
174195
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
174196
|
+
noise_level_nrs?: number | undefined
|
|
174197
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
174198
|
+
co2_ppm?: number | undefined
|
|
174199
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
174200
|
+
co_ppm?: number | undefined
|
|
174201
|
+
/** Air quality index, if the device measures it. */
|
|
174202
|
+
air_quality_index?: number | undefined
|
|
174203
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
174204
|
+
mold_risk_level?: string | undefined
|
|
174205
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
174206
|
+
is_occupied?: boolean | undefined
|
|
174207
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
174208
|
+
occupant_count?: number | undefined
|
|
174209
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
174210
|
+
is_smoking_detected?: boolean | undefined
|
|
174211
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
174212
|
+
named_sensors?:
|
|
174213
|
+
| {
|
|
174214
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
174215
|
+
sensor_name: string
|
|
174216
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
174217
|
+
display_name: string
|
|
174218
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
174219
|
+
temperature_celsius?: number | undefined
|
|
174220
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
174221
|
+
temperature_fahrenheit?: number | undefined
|
|
174222
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
174223
|
+
relative_humidity?: number | undefined
|
|
174224
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
174225
|
+
noise_level_decibels?: number | undefined
|
|
174226
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
174227
|
+
noise_level_nrs?: number | undefined
|
|
174228
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
174229
|
+
co2_ppm?: number | undefined
|
|
174230
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
174231
|
+
co_ppm?: number | undefined
|
|
174232
|
+
/** Air quality index, if the device measures it. */
|
|
174233
|
+
air_quality_index?: number | undefined
|
|
174234
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
174235
|
+
mold_risk_level?: string | undefined
|
|
174236
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
174237
|
+
is_occupied?: boolean | undefined
|
|
174238
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
174239
|
+
occupant_count?: number | undefined
|
|
174240
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
174241
|
+
is_smoking_detected?: boolean | undefined
|
|
174242
|
+
}[]
|
|
174243
|
+
| undefined
|
|
174132
174244
|
/** Indicates whether the device supports remote unlocking. */
|
|
174133
174245
|
can_remotely_unlock?: boolean | undefined
|
|
174134
174246
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -185728,58 +185840,9 @@ export type Routes = {
|
|
|
185728
185840
|
* @deprecated use offline_access_codes_enabled*/
|
|
185729
185841
|
supports_offline_access_codes?: boolean | undefined
|
|
185730
185842
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
185731
|
-
noise_level_decibels?:
|
|
185843
|
+
noise_level_decibels?: number | undefined
|
|
185732
185844
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
185733
185845
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
185734
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
185735
|
-
noise_level_nrs?: (number | null) | undefined
|
|
185736
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
185737
|
-
co2_ppm?: (number | null) | undefined
|
|
185738
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
185739
|
-
co_ppm?: (number | null) | undefined
|
|
185740
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
185741
|
-
air_quality_index?: (number | null) | undefined
|
|
185742
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
185743
|
-
mold_risk_level?: (string | null) | undefined
|
|
185744
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
185745
|
-
is_occupied?: (boolean | null) | undefined
|
|
185746
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
185747
|
-
occupant_count?: (number | null) | undefined
|
|
185748
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
185749
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
185750
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
185751
|
-
named_sensors?:
|
|
185752
|
-
| {
|
|
185753
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
185754
|
-
sensor_name: string
|
|
185755
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
185756
|
-
display_name: string
|
|
185757
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
185758
|
-
temperature_celsius?: (number | null) | undefined
|
|
185759
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
185760
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
185761
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
185762
|
-
relative_humidity?: (number | null) | undefined
|
|
185763
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
185764
|
-
noise_level_decibels?: (number | null) | undefined
|
|
185765
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
185766
|
-
noise_level_nrs?: (number | null) | undefined
|
|
185767
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
185768
|
-
co2_ppm?: (number | null) | undefined
|
|
185769
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
185770
|
-
co_ppm?: (number | null) | undefined
|
|
185771
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
185772
|
-
air_quality_index?: (number | null) | undefined
|
|
185773
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
185774
|
-
mold_risk_level?: (string | null) | undefined
|
|
185775
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
185776
|
-
is_occupied?: (boolean | null) | undefined
|
|
185777
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
185778
|
-
occupant_count?: (number | null) | undefined
|
|
185779
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
185780
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
185781
|
-
}[]
|
|
185782
|
-
| undefined
|
|
185783
185846
|
} & {
|
|
185784
185847
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
185785
185848
|
assa_abloy_credential_service_metadata?:
|
|
@@ -186837,11 +186900,11 @@ export type Routes = {
|
|
|
186837
186900
|
| undefined
|
|
186838
186901
|
} & {
|
|
186839
186902
|
/** Reported temperature in °F. */
|
|
186840
|
-
temperature_fahrenheit?:
|
|
186903
|
+
temperature_fahrenheit?: number | undefined
|
|
186841
186904
|
/** Reported temperature in °C. */
|
|
186842
|
-
temperature_celsius?:
|
|
186905
|
+
temperature_celsius?: number | undefined
|
|
186843
186906
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
186844
|
-
relative_humidity?:
|
|
186907
|
+
relative_humidity?: number | undefined
|
|
186845
186908
|
/** HVAC mode settings that the thermostat supports. */
|
|
186846
186909
|
available_hvac_mode_settings?:
|
|
186847
186910
|
('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined
|
|
@@ -187654,6 +187717,63 @@ export type Routes = {
|
|
|
187654
187717
|
image_url?: string | undefined
|
|
187655
187718
|
}
|
|
187656
187719
|
| undefined
|
|
187720
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
187721
|
+
temperature_celsius?: number | undefined
|
|
187722
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
187723
|
+
temperature_fahrenheit?: number | undefined
|
|
187724
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
187725
|
+
relative_humidity?: number | undefined
|
|
187726
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
187727
|
+
noise_level_decibels?: number | undefined
|
|
187728
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
187729
|
+
noise_level_nrs?: number | undefined
|
|
187730
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
187731
|
+
co2_ppm?: number | undefined
|
|
187732
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
187733
|
+
co_ppm?: number | undefined
|
|
187734
|
+
/** Air quality index, if the device measures it. */
|
|
187735
|
+
air_quality_index?: number | undefined
|
|
187736
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
187737
|
+
mold_risk_level?: string | undefined
|
|
187738
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
187739
|
+
is_occupied?: boolean | undefined
|
|
187740
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
187741
|
+
occupant_count?: number | undefined
|
|
187742
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
187743
|
+
is_smoking_detected?: boolean | undefined
|
|
187744
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
187745
|
+
named_sensors?:
|
|
187746
|
+
| {
|
|
187747
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
187748
|
+
sensor_name: string
|
|
187749
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
187750
|
+
display_name: string
|
|
187751
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
187752
|
+
temperature_celsius?: number | undefined
|
|
187753
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
187754
|
+
temperature_fahrenheit?: number | undefined
|
|
187755
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
187756
|
+
relative_humidity?: number | undefined
|
|
187757
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
187758
|
+
noise_level_decibels?: number | undefined
|
|
187759
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
187760
|
+
noise_level_nrs?: number | undefined
|
|
187761
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
187762
|
+
co2_ppm?: number | undefined
|
|
187763
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
187764
|
+
co_ppm?: number | undefined
|
|
187765
|
+
/** Air quality index, if the device measures it. */
|
|
187766
|
+
air_quality_index?: number | undefined
|
|
187767
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
187768
|
+
mold_risk_level?: string | undefined
|
|
187769
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
187770
|
+
is_occupied?: boolean | undefined
|
|
187771
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
187772
|
+
occupant_count?: number | undefined
|
|
187773
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
187774
|
+
is_smoking_detected?: boolean | undefined
|
|
187775
|
+
}[]
|
|
187776
|
+
| undefined
|
|
187657
187777
|
/** Indicates whether the device supports remote unlocking. */
|
|
187658
187778
|
can_remotely_unlock?: boolean | undefined
|
|
187659
187779
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -187888,58 +188008,9 @@ export type Routes = {
|
|
|
187888
188008
|
* @deprecated use offline_access_codes_enabled*/
|
|
187889
188009
|
supports_offline_access_codes?: boolean | undefined
|
|
187890
188010
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
187891
|
-
noise_level_decibels?:
|
|
188011
|
+
noise_level_decibels?: number | undefined
|
|
187892
188012
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
187893
188013
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
187894
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
187895
|
-
noise_level_nrs?: (number | null) | undefined
|
|
187896
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
187897
|
-
co2_ppm?: (number | null) | undefined
|
|
187898
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
187899
|
-
co_ppm?: (number | null) | undefined
|
|
187900
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
187901
|
-
air_quality_index?: (number | null) | undefined
|
|
187902
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
187903
|
-
mold_risk_level?: (string | null) | undefined
|
|
187904
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
187905
|
-
is_occupied?: (boolean | null) | undefined
|
|
187906
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
187907
|
-
occupant_count?: (number | null) | undefined
|
|
187908
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
187909
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
187910
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
187911
|
-
named_sensors?:
|
|
187912
|
-
| {
|
|
187913
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
187914
|
-
sensor_name: string
|
|
187915
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
187916
|
-
display_name: string
|
|
187917
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
187918
|
-
temperature_celsius?: (number | null) | undefined
|
|
187919
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
187920
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
187921
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
187922
|
-
relative_humidity?: (number | null) | undefined
|
|
187923
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
187924
|
-
noise_level_decibels?: (number | null) | undefined
|
|
187925
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
187926
|
-
noise_level_nrs?: (number | null) | undefined
|
|
187927
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
187928
|
-
co2_ppm?: (number | null) | undefined
|
|
187929
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
187930
|
-
co_ppm?: (number | null) | undefined
|
|
187931
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
187932
|
-
air_quality_index?: (number | null) | undefined
|
|
187933
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
187934
|
-
mold_risk_level?: (string | null) | undefined
|
|
187935
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
187936
|
-
is_occupied?: (boolean | null) | undefined
|
|
187937
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
187938
|
-
occupant_count?: (number | null) | undefined
|
|
187939
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
187940
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
187941
|
-
}[]
|
|
187942
|
-
| undefined
|
|
187943
188014
|
} & {
|
|
187944
188015
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
187945
188016
|
assa_abloy_credential_service_metadata?:
|
|
@@ -188997,11 +189068,11 @@ export type Routes = {
|
|
|
188997
189068
|
| undefined
|
|
188998
189069
|
} & {
|
|
188999
189070
|
/** Reported temperature in °F. */
|
|
189000
|
-
temperature_fahrenheit?:
|
|
189071
|
+
temperature_fahrenheit?: number | undefined
|
|
189001
189072
|
/** Reported temperature in °C. */
|
|
189002
|
-
temperature_celsius?:
|
|
189073
|
+
temperature_celsius?: number | undefined
|
|
189003
189074
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
189004
|
-
relative_humidity?:
|
|
189075
|
+
relative_humidity?: number | undefined
|
|
189005
189076
|
/** HVAC mode settings that the thermostat supports. */
|
|
189006
189077
|
available_hvac_mode_settings?:
|
|
189007
189078
|
('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined
|
|
@@ -189814,6 +189885,63 @@ export type Routes = {
|
|
|
189814
189885
|
image_url?: string | undefined
|
|
189815
189886
|
}
|
|
189816
189887
|
| undefined
|
|
189888
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
189889
|
+
temperature_celsius?: number | undefined
|
|
189890
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
189891
|
+
temperature_fahrenheit?: number | undefined
|
|
189892
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
189893
|
+
relative_humidity?: number | undefined
|
|
189894
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
189895
|
+
noise_level_decibels?: number | undefined
|
|
189896
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
189897
|
+
noise_level_nrs?: number | undefined
|
|
189898
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
189899
|
+
co2_ppm?: number | undefined
|
|
189900
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
189901
|
+
co_ppm?: number | undefined
|
|
189902
|
+
/** Air quality index, if the device measures it. */
|
|
189903
|
+
air_quality_index?: number | undefined
|
|
189904
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
189905
|
+
mold_risk_level?: string | undefined
|
|
189906
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
189907
|
+
is_occupied?: boolean | undefined
|
|
189908
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
189909
|
+
occupant_count?: number | undefined
|
|
189910
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
189911
|
+
is_smoking_detected?: boolean | undefined
|
|
189912
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
189913
|
+
named_sensors?:
|
|
189914
|
+
| {
|
|
189915
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
189916
|
+
sensor_name: string
|
|
189917
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
189918
|
+
display_name: string
|
|
189919
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
189920
|
+
temperature_celsius?: number | undefined
|
|
189921
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
189922
|
+
temperature_fahrenheit?: number | undefined
|
|
189923
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
189924
|
+
relative_humidity?: number | undefined
|
|
189925
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
189926
|
+
noise_level_decibels?: number | undefined
|
|
189927
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
189928
|
+
noise_level_nrs?: number | undefined
|
|
189929
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
189930
|
+
co2_ppm?: number | undefined
|
|
189931
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
189932
|
+
co_ppm?: number | undefined
|
|
189933
|
+
/** Air quality index, if the device measures it. */
|
|
189934
|
+
air_quality_index?: number | undefined
|
|
189935
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
189936
|
+
mold_risk_level?: string | undefined
|
|
189937
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
189938
|
+
is_occupied?: boolean | undefined
|
|
189939
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
189940
|
+
occupant_count?: number | undefined
|
|
189941
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
189942
|
+
is_smoking_detected?: boolean | undefined
|
|
189943
|
+
}[]
|
|
189944
|
+
| undefined
|
|
189817
189945
|
/** Indicates whether the device supports remote unlocking. */
|
|
189818
189946
|
can_remotely_unlock?: boolean | undefined
|
|
189819
189947
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -192763,58 +192891,9 @@ export type Routes = {
|
|
|
192763
192891
|
* @deprecated use offline_access_codes_enabled*/
|
|
192764
192892
|
supports_offline_access_codes?: boolean | undefined
|
|
192765
192893
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
192766
|
-
noise_level_decibels?:
|
|
192894
|
+
noise_level_decibels?: number | undefined
|
|
192767
192895
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
192768
192896
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
192769
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
192770
|
-
noise_level_nrs?: (number | null) | undefined
|
|
192771
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
192772
|
-
co2_ppm?: (number | null) | undefined
|
|
192773
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
192774
|
-
co_ppm?: (number | null) | undefined
|
|
192775
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
192776
|
-
air_quality_index?: (number | null) | undefined
|
|
192777
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
192778
|
-
mold_risk_level?: (string | null) | undefined
|
|
192779
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
192780
|
-
is_occupied?: (boolean | null) | undefined
|
|
192781
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
192782
|
-
occupant_count?: (number | null) | undefined
|
|
192783
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
192784
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
192785
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
192786
|
-
named_sensors?:
|
|
192787
|
-
| {
|
|
192788
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
192789
|
-
sensor_name: string
|
|
192790
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
192791
|
-
display_name: string
|
|
192792
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
192793
|
-
temperature_celsius?: (number | null) | undefined
|
|
192794
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
192795
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
192796
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
192797
|
-
relative_humidity?: (number | null) | undefined
|
|
192798
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
192799
|
-
noise_level_decibels?: (number | null) | undefined
|
|
192800
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
192801
|
-
noise_level_nrs?: (number | null) | undefined
|
|
192802
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
192803
|
-
co2_ppm?: (number | null) | undefined
|
|
192804
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
192805
|
-
co_ppm?: (number | null) | undefined
|
|
192806
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
192807
|
-
air_quality_index?: (number | null) | undefined
|
|
192808
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
192809
|
-
mold_risk_level?: (string | null) | undefined
|
|
192810
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
192811
|
-
is_occupied?: (boolean | null) | undefined
|
|
192812
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
192813
|
-
occupant_count?: (number | null) | undefined
|
|
192814
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
192815
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
192816
|
-
}[]
|
|
192817
|
-
| undefined
|
|
192818
192897
|
} & {
|
|
192819
192898
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
192820
192899
|
assa_abloy_credential_service_metadata?:
|
|
@@ -193907,11 +193986,11 @@ export type Routes = {
|
|
|
193907
193986
|
| undefined
|
|
193908
193987
|
} & {
|
|
193909
193988
|
/** Reported temperature in °F. */
|
|
193910
|
-
temperature_fahrenheit?:
|
|
193989
|
+
temperature_fahrenheit?: number | undefined
|
|
193911
193990
|
/** Reported temperature in °C. */
|
|
193912
|
-
temperature_celsius?:
|
|
193991
|
+
temperature_celsius?: number | undefined
|
|
193913
193992
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
193914
|
-
relative_humidity?:
|
|
193993
|
+
relative_humidity?: number | undefined
|
|
193915
193994
|
/** HVAC mode settings that the thermostat supports. */
|
|
193916
193995
|
available_hvac_mode_settings?:
|
|
193917
193996
|
| ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[]
|
|
@@ -194746,6 +194825,63 @@ export type Routes = {
|
|
|
194746
194825
|
image_url?: string | undefined
|
|
194747
194826
|
}
|
|
194748
194827
|
| undefined
|
|
194828
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
194829
|
+
temperature_celsius?: number | undefined
|
|
194830
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
194831
|
+
temperature_fahrenheit?: number | undefined
|
|
194832
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
194833
|
+
relative_humidity?: number | undefined
|
|
194834
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
194835
|
+
noise_level_decibels?: number | undefined
|
|
194836
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
194837
|
+
noise_level_nrs?: number | undefined
|
|
194838
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
194839
|
+
co2_ppm?: number | undefined
|
|
194840
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
194841
|
+
co_ppm?: number | undefined
|
|
194842
|
+
/** Air quality index, if the device measures it. */
|
|
194843
|
+
air_quality_index?: number | undefined
|
|
194844
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
194845
|
+
mold_risk_level?: string | undefined
|
|
194846
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
194847
|
+
is_occupied?: boolean | undefined
|
|
194848
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
194849
|
+
occupant_count?: number | undefined
|
|
194850
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
194851
|
+
is_smoking_detected?: boolean | undefined
|
|
194852
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
194853
|
+
named_sensors?:
|
|
194854
|
+
| {
|
|
194855
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
194856
|
+
sensor_name: string
|
|
194857
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
194858
|
+
display_name: string
|
|
194859
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
194860
|
+
temperature_celsius?: number | undefined
|
|
194861
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
194862
|
+
temperature_fahrenheit?: number | undefined
|
|
194863
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
194864
|
+
relative_humidity?: number | undefined
|
|
194865
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
194866
|
+
noise_level_decibels?: number | undefined
|
|
194867
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
194868
|
+
noise_level_nrs?: number | undefined
|
|
194869
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
194870
|
+
co2_ppm?: number | undefined
|
|
194871
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
194872
|
+
co_ppm?: number | undefined
|
|
194873
|
+
/** Air quality index, if the device measures it. */
|
|
194874
|
+
air_quality_index?: number | undefined
|
|
194875
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
194876
|
+
mold_risk_level?: string | undefined
|
|
194877
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
194878
|
+
is_occupied?: boolean | undefined
|
|
194879
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
194880
|
+
occupant_count?: number | undefined
|
|
194881
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
194882
|
+
is_smoking_detected?: boolean | undefined
|
|
194883
|
+
}[]
|
|
194884
|
+
| undefined
|
|
194749
194885
|
/** Indicates whether the device supports remote unlocking. */
|
|
194750
194886
|
can_remotely_unlock?: boolean | undefined
|
|
194751
194887
|
/** Indicates whether the device supports remote locking. */
|