@seamapi/types 1.1185.0 → 1.1187.0
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/lib/seam/connect/models/devices/capability-properties/index.d.ts +9 -9
- package/lib/seam/connect/models/devices/capability-properties/thermostat.d.ts +9 -9
- package/lib/seam/connect/models/devices/capability-properties/thermostat.js +3 -3
- package/lib/seam/connect/models/devices/capability-properties/thermostat.js.map +1 -1
- package/lib/seam/connect/models/devices/device-metadata.d.ts +33 -0
- package/lib/seam/connect/models/devices/device-metadata.js +31 -0
- package/lib/seam/connect/models/devices/device-metadata.js.map +1 -1
- package/lib/seam/connect/models/devices/device-provider.d.ts +2 -1
- package/lib/seam/connect/models/devices/device-provider.js +2 -0
- package/lib/seam/connect/models/devices/device-provider.js.map +1 -1
- package/lib/seam/connect/models/devices/device-type.d.ts +7 -1
- package/lib/seam/connect/models/devices/device-type.js +8 -0
- package/lib/seam/connect/models/devices/device-type.js.map +1 -1
- package/lib/seam/connect/models/devices/device.d.ts +223 -314
- package/lib/seam/connect/models/devices/device.js +60 -73
- package/lib/seam/connect/models/devices/device.js.map +1 -1
- package/lib/seam/connect/models/devices/unmanaged-device.d.ts +107 -172
- package/lib/seam/connect/openapi.js +229 -167
- package/lib/seam/connect/openapi.js.map +1 -1
- package/lib/seam/connect/route-types.d.ts +1253 -896
- package/package.json +1 -1
- package/src/lib/seam/connect/models/devices/capability-properties/thermostat.ts +3 -3
- package/src/lib/seam/connect/models/devices/device-metadata.ts +32 -0
- package/src/lib/seam/connect/models/devices/device-provider.ts +2 -0
- package/src/lib/seam/connect/models/devices/device-type.ts +16 -0
- package/src/lib/seam/connect/models/devices/device.ts +63 -76
- package/src/lib/seam/connect/openapi.ts +259 -191
- package/src/lib/seam/connect/route-types.ts +1376 -902
|
@@ -16121,6 +16121,7 @@ export type Routes = {
|
|
|
16121
16121
|
| 'unifi_protect_camera'
|
|
16122
16122
|
)
|
|
16123
16123
|
| 'sonos_speaker'
|
|
16124
|
+
| 'alertify_sensor'
|
|
16124
16125
|
/** IDs of the spaces the device is in. */
|
|
16125
16126
|
space_ids: string[]
|
|
16126
16127
|
/** Optional nickname to describe the device, settable through Seam. */
|
|
@@ -16229,58 +16230,9 @@ export type Routes = {
|
|
|
16229
16230
|
* @deprecated use offline_access_codes_enabled*/
|
|
16230
16231
|
supports_offline_access_codes?: boolean | undefined
|
|
16231
16232
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
16232
|
-
noise_level_decibels?:
|
|
16233
|
+
noise_level_decibels?: number | undefined
|
|
16233
16234
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
16234
16235
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
16235
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
16236
|
-
noise_level_nrs?: (number | null) | undefined
|
|
16237
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
16238
|
-
co2_ppm?: (number | null) | undefined
|
|
16239
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
16240
|
-
co_ppm?: (number | null) | undefined
|
|
16241
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
16242
|
-
air_quality_index?: (number | null) | undefined
|
|
16243
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
16244
|
-
mold_risk_level?: (string | null) | undefined
|
|
16245
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
16246
|
-
is_occupied?: (boolean | null) | undefined
|
|
16247
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
16248
|
-
occupant_count?: (number | null) | undefined
|
|
16249
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
16250
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
16251
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
16252
|
-
named_sensors?:
|
|
16253
|
-
| {
|
|
16254
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
16255
|
-
sensor_name: string
|
|
16256
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
16257
|
-
display_name: string
|
|
16258
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
16259
|
-
temperature_celsius?: (number | null) | undefined
|
|
16260
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
16261
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
16262
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
16263
|
-
relative_humidity?: (number | null) | undefined
|
|
16264
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
16265
|
-
noise_level_decibels?: (number | null) | undefined
|
|
16266
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
16267
|
-
noise_level_nrs?: (number | null) | undefined
|
|
16268
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
16269
|
-
co2_ppm?: (number | null) | undefined
|
|
16270
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
16271
|
-
co_ppm?: (number | null) | undefined
|
|
16272
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
16273
|
-
air_quality_index?: (number | null) | undefined
|
|
16274
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
16275
|
-
mold_risk_level?: (string | null) | undefined
|
|
16276
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
16277
|
-
is_occupied?: (boolean | null) | undefined
|
|
16278
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
16279
|
-
occupant_count?: (number | null) | undefined
|
|
16280
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
16281
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
16282
|
-
}[]
|
|
16283
|
-
| undefined
|
|
16284
16236
|
} & {
|
|
16285
16237
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
16286
16238
|
assa_abloy_credential_service_metadata?:
|
|
@@ -17047,6 +16999,25 @@ export type Routes = {
|
|
|
17047
16999
|
| undefined
|
|
17048
17000
|
)
|
|
17049
17001
|
| undefined
|
|
17002
|
+
/** Metadata for an Alertify sensor. */
|
|
17003
|
+
alertify_metadata?:
|
|
17004
|
+
| (
|
|
17005
|
+
| {
|
|
17006
|
+
/** Device ID reported by Alertify. */
|
|
17007
|
+
device_id?: (string | undefined) | undefined
|
|
17008
|
+
/** Device name, as set in the Alertify dashboard. */
|
|
17009
|
+
device_name?: (string | undefined) | undefined
|
|
17010
|
+
/** ID of the Alertify unit where the device is installed. */
|
|
17011
|
+
unit_id?: (string | undefined) | undefined
|
|
17012
|
+
/** Name of the Alertify unit where the device is installed. */
|
|
17013
|
+
unit_name?: (string | undefined) | undefined
|
|
17014
|
+
/** ID of the Alertify building that contains the unit. */
|
|
17015
|
+
building_id?:
|
|
17016
|
+
((string | null) | undefined) | undefined
|
|
17017
|
+
}
|
|
17018
|
+
| undefined
|
|
17019
|
+
)
|
|
17020
|
+
| undefined
|
|
17050
17021
|
/** Metadata for a UniFi Protect camera. */
|
|
17051
17022
|
unifi_protect_metadata?:
|
|
17052
17023
|
| (
|
|
@@ -17354,11 +17325,11 @@ export type Routes = {
|
|
|
17354
17325
|
| undefined
|
|
17355
17326
|
} & {
|
|
17356
17327
|
/** Reported temperature in °F. */
|
|
17357
|
-
temperature_fahrenheit?:
|
|
17328
|
+
temperature_fahrenheit?: number | undefined
|
|
17358
17329
|
/** Reported temperature in °C. */
|
|
17359
|
-
temperature_celsius?:
|
|
17330
|
+
temperature_celsius?: number | undefined
|
|
17360
17331
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
17361
|
-
relative_humidity?:
|
|
17332
|
+
relative_humidity?: number | undefined
|
|
17362
17333
|
/** HVAC mode settings that the thermostat supports. */
|
|
17363
17334
|
available_hvac_mode_settings?:
|
|
17364
17335
|
| ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[]
|
|
@@ -18193,6 +18164,63 @@ export type Routes = {
|
|
|
18193
18164
|
image_url?: string | undefined
|
|
18194
18165
|
}
|
|
18195
18166
|
| undefined
|
|
18167
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
18168
|
+
temperature_celsius?: number | undefined
|
|
18169
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
18170
|
+
temperature_fahrenheit?: number | undefined
|
|
18171
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
18172
|
+
relative_humidity?: number | undefined
|
|
18173
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
18174
|
+
noise_level_decibels?: number | undefined
|
|
18175
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
18176
|
+
noise_level_nrs?: number | undefined
|
|
18177
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
18178
|
+
co2_ppm?: number | undefined
|
|
18179
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
18180
|
+
co_ppm?: number | undefined
|
|
18181
|
+
/** Air quality index, if the device measures it. */
|
|
18182
|
+
air_quality_index?: number | undefined
|
|
18183
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
18184
|
+
mold_risk_level?: string | undefined
|
|
18185
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
18186
|
+
is_occupied?: boolean | undefined
|
|
18187
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
18188
|
+
occupant_count?: number | undefined
|
|
18189
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
18190
|
+
is_smoking_detected?: boolean | undefined
|
|
18191
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
18192
|
+
named_sensors?:
|
|
18193
|
+
| {
|
|
18194
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
18195
|
+
sensor_name: string
|
|
18196
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
18197
|
+
display_name: string
|
|
18198
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
18199
|
+
temperature_celsius?: number | undefined
|
|
18200
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
18201
|
+
temperature_fahrenheit?: number | undefined
|
|
18202
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
18203
|
+
relative_humidity?: number | undefined
|
|
18204
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
18205
|
+
noise_level_decibels?: number | undefined
|
|
18206
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
18207
|
+
noise_level_nrs?: number | undefined
|
|
18208
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
18209
|
+
co2_ppm?: number | undefined
|
|
18210
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
18211
|
+
co_ppm?: number | undefined
|
|
18212
|
+
/** Air quality index, if the device measures it. */
|
|
18213
|
+
air_quality_index?: number | undefined
|
|
18214
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
18215
|
+
mold_risk_level?: string | undefined
|
|
18216
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
18217
|
+
is_occupied?: boolean | undefined
|
|
18218
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
18219
|
+
occupant_count?: number | undefined
|
|
18220
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
18221
|
+
is_smoking_detected?: boolean | undefined
|
|
18222
|
+
}[]
|
|
18223
|
+
| undefined
|
|
18196
18224
|
/** Indicates whether the device supports remote unlocking. */
|
|
18197
18225
|
can_remotely_unlock?: boolean | undefined
|
|
18198
18226
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -25938,6 +25966,7 @@ export type Routes = {
|
|
|
25938
25966
|
| 'unifi_protect_camera'
|
|
25939
25967
|
)
|
|
25940
25968
|
| 'sonos_speaker'
|
|
25969
|
+
| 'alertify_sensor'
|
|
25941
25970
|
/** IDs of the spaces the device is in. */
|
|
25942
25971
|
space_ids: string[]
|
|
25943
25972
|
/** Optional nickname to describe the device, settable through Seam. */
|
|
@@ -26046,58 +26075,9 @@ export type Routes = {
|
|
|
26046
26075
|
* @deprecated use offline_access_codes_enabled*/
|
|
26047
26076
|
supports_offline_access_codes?: boolean | undefined
|
|
26048
26077
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
26049
|
-
noise_level_decibels?:
|
|
26078
|
+
noise_level_decibels?: number | undefined
|
|
26050
26079
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
26051
26080
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
26052
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
26053
|
-
noise_level_nrs?: (number | null) | undefined
|
|
26054
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
26055
|
-
co2_ppm?: (number | null) | undefined
|
|
26056
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
26057
|
-
co_ppm?: (number | null) | undefined
|
|
26058
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
26059
|
-
air_quality_index?: (number | null) | undefined
|
|
26060
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
26061
|
-
mold_risk_level?: (string | null) | undefined
|
|
26062
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
26063
|
-
is_occupied?: (boolean | null) | undefined
|
|
26064
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
26065
|
-
occupant_count?: (number | null) | undefined
|
|
26066
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
26067
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
26068
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
26069
|
-
named_sensors?:
|
|
26070
|
-
| {
|
|
26071
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
26072
|
-
sensor_name: string
|
|
26073
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
26074
|
-
display_name: string
|
|
26075
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
26076
|
-
temperature_celsius?: (number | null) | undefined
|
|
26077
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
26078
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
26079
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
26080
|
-
relative_humidity?: (number | null) | undefined
|
|
26081
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
26082
|
-
noise_level_decibels?: (number | null) | undefined
|
|
26083
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
26084
|
-
noise_level_nrs?: (number | null) | undefined
|
|
26085
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
26086
|
-
co2_ppm?: (number | null) | undefined
|
|
26087
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
26088
|
-
co_ppm?: (number | null) | undefined
|
|
26089
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
26090
|
-
air_quality_index?: (number | null) | undefined
|
|
26091
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
26092
|
-
mold_risk_level?: (string | null) | undefined
|
|
26093
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
26094
|
-
is_occupied?: (boolean | null) | undefined
|
|
26095
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
26096
|
-
occupant_count?: (number | null) | undefined
|
|
26097
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
26098
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
26099
|
-
}[]
|
|
26100
|
-
| undefined
|
|
26101
26081
|
} & {
|
|
26102
26082
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
26103
26083
|
assa_abloy_credential_service_metadata?:
|
|
@@ -26864,6 +26844,25 @@ export type Routes = {
|
|
|
26864
26844
|
| undefined
|
|
26865
26845
|
)
|
|
26866
26846
|
| undefined
|
|
26847
|
+
/** Metadata for an Alertify sensor. */
|
|
26848
|
+
alertify_metadata?:
|
|
26849
|
+
| (
|
|
26850
|
+
| {
|
|
26851
|
+
/** Device ID reported by Alertify. */
|
|
26852
|
+
device_id?: (string | undefined) | undefined
|
|
26853
|
+
/** Device name, as set in the Alertify dashboard. */
|
|
26854
|
+
device_name?: (string | undefined) | undefined
|
|
26855
|
+
/** ID of the Alertify unit where the device is installed. */
|
|
26856
|
+
unit_id?: (string | undefined) | undefined
|
|
26857
|
+
/** Name of the Alertify unit where the device is installed. */
|
|
26858
|
+
unit_name?: (string | undefined) | undefined
|
|
26859
|
+
/** ID of the Alertify building that contains the unit. */
|
|
26860
|
+
building_id?:
|
|
26861
|
+
((string | null) | undefined) | undefined
|
|
26862
|
+
}
|
|
26863
|
+
| undefined
|
|
26864
|
+
)
|
|
26865
|
+
| undefined
|
|
26867
26866
|
/** Metadata for a UniFi Protect camera. */
|
|
26868
26867
|
unifi_protect_metadata?:
|
|
26869
26868
|
| (
|
|
@@ -27171,11 +27170,11 @@ export type Routes = {
|
|
|
27171
27170
|
| undefined
|
|
27172
27171
|
} & {
|
|
27173
27172
|
/** Reported temperature in °F. */
|
|
27174
|
-
temperature_fahrenheit?:
|
|
27173
|
+
temperature_fahrenheit?: number | undefined
|
|
27175
27174
|
/** Reported temperature in °C. */
|
|
27176
|
-
temperature_celsius?:
|
|
27175
|
+
temperature_celsius?: number | undefined
|
|
27177
27176
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
27178
|
-
relative_humidity?:
|
|
27177
|
+
relative_humidity?: number | undefined
|
|
27179
27178
|
/** HVAC mode settings that the thermostat supports. */
|
|
27180
27179
|
available_hvac_mode_settings?:
|
|
27181
27180
|
| ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[]
|
|
@@ -28010,6 +28009,63 @@ export type Routes = {
|
|
|
28010
28009
|
image_url?: string | undefined
|
|
28011
28010
|
}
|
|
28012
28011
|
| undefined
|
|
28012
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
28013
|
+
temperature_celsius?: number | undefined
|
|
28014
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
28015
|
+
temperature_fahrenheit?: number | undefined
|
|
28016
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
28017
|
+
relative_humidity?: number | undefined
|
|
28018
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
28019
|
+
noise_level_decibels?: number | undefined
|
|
28020
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
28021
|
+
noise_level_nrs?: number | undefined
|
|
28022
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
28023
|
+
co2_ppm?: number | undefined
|
|
28024
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
28025
|
+
co_ppm?: number | undefined
|
|
28026
|
+
/** Air quality index, if the device measures it. */
|
|
28027
|
+
air_quality_index?: number | undefined
|
|
28028
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
28029
|
+
mold_risk_level?: string | undefined
|
|
28030
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
28031
|
+
is_occupied?: boolean | undefined
|
|
28032
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
28033
|
+
occupant_count?: number | undefined
|
|
28034
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
28035
|
+
is_smoking_detected?: boolean | undefined
|
|
28036
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
28037
|
+
named_sensors?:
|
|
28038
|
+
| {
|
|
28039
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
28040
|
+
sensor_name: string
|
|
28041
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
28042
|
+
display_name: string
|
|
28043
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
28044
|
+
temperature_celsius?: number | undefined
|
|
28045
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
28046
|
+
temperature_fahrenheit?: number | undefined
|
|
28047
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
28048
|
+
relative_humidity?: number | undefined
|
|
28049
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
28050
|
+
noise_level_decibels?: number | undefined
|
|
28051
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
28052
|
+
noise_level_nrs?: number | undefined
|
|
28053
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
28054
|
+
co2_ppm?: number | undefined
|
|
28055
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
28056
|
+
co_ppm?: number | undefined
|
|
28057
|
+
/** Air quality index, if the device measures it. */
|
|
28058
|
+
air_quality_index?: number | undefined
|
|
28059
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
28060
|
+
mold_risk_level?: string | undefined
|
|
28061
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
28062
|
+
is_occupied?: boolean | undefined
|
|
28063
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
28064
|
+
occupant_count?: number | undefined
|
|
28065
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
28066
|
+
is_smoking_detected?: boolean | undefined
|
|
28067
|
+
}[]
|
|
28068
|
+
| undefined
|
|
28013
28069
|
/** Indicates whether the device supports remote unlocking. */
|
|
28014
28070
|
can_remotely_unlock?: boolean | undefined
|
|
28015
28071
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -55881,6 +55937,7 @@ export type Routes = {
|
|
|
55881
55937
|
| 'reolink'
|
|
55882
55938
|
| 'unifi_protect'
|
|
55883
55939
|
| 'yale_connect'
|
|
55940
|
+
| 'alertify'
|
|
55884
55941
|
| 'ical'
|
|
55885
55942
|
| 'lodgify'
|
|
55886
55943
|
| 'hostaway'
|
|
@@ -58235,6 +58292,7 @@ export type Routes = {
|
|
|
58235
58292
|
| 'unifi_protect_camera'
|
|
58236
58293
|
)
|
|
58237
58294
|
| 'sonos_speaker'
|
|
58295
|
+
| 'alertify_sensor'
|
|
58238
58296
|
/** IDs of the spaces the device is in. */
|
|
58239
58297
|
space_ids: string[]
|
|
58240
58298
|
/** Optional nickname to describe the device, settable through Seam. */
|
|
@@ -58343,58 +58401,9 @@ export type Routes = {
|
|
|
58343
58401
|
* @deprecated use offline_access_codes_enabled*/
|
|
58344
58402
|
supports_offline_access_codes?: boolean | undefined
|
|
58345
58403
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
58346
|
-
noise_level_decibels?:
|
|
58404
|
+
noise_level_decibels?: number | undefined
|
|
58347
58405
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
58348
58406
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
58349
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
58350
|
-
noise_level_nrs?: (number | null) | undefined
|
|
58351
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
58352
|
-
co2_ppm?: (number | null) | undefined
|
|
58353
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
58354
|
-
co_ppm?: (number | null) | undefined
|
|
58355
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
58356
|
-
air_quality_index?: (number | null) | undefined
|
|
58357
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
58358
|
-
mold_risk_level?: (string | null) | undefined
|
|
58359
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
58360
|
-
is_occupied?: (boolean | null) | undefined
|
|
58361
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
58362
|
-
occupant_count?: (number | null) | undefined
|
|
58363
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
58364
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
58365
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
58366
|
-
named_sensors?:
|
|
58367
|
-
| {
|
|
58368
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
58369
|
-
sensor_name: string
|
|
58370
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
58371
|
-
display_name: string
|
|
58372
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
58373
|
-
temperature_celsius?: (number | null) | undefined
|
|
58374
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
58375
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
58376
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
58377
|
-
relative_humidity?: (number | null) | undefined
|
|
58378
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
58379
|
-
noise_level_decibels?: (number | null) | undefined
|
|
58380
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
58381
|
-
noise_level_nrs?: (number | null) | undefined
|
|
58382
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
58383
|
-
co2_ppm?: (number | null) | undefined
|
|
58384
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
58385
|
-
co_ppm?: (number | null) | undefined
|
|
58386
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
58387
|
-
air_quality_index?: (number | null) | undefined
|
|
58388
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
58389
|
-
mold_risk_level?: (string | null) | undefined
|
|
58390
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
58391
|
-
is_occupied?: (boolean | null) | undefined
|
|
58392
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
58393
|
-
occupant_count?: (number | null) | undefined
|
|
58394
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
58395
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
58396
|
-
}[]
|
|
58397
|
-
| undefined
|
|
58398
58407
|
} & {
|
|
58399
58408
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
58400
58409
|
assa_abloy_credential_service_metadata?:
|
|
@@ -59136,6 +59145,24 @@ export type Routes = {
|
|
|
59136
59145
|
| undefined
|
|
59137
59146
|
)
|
|
59138
59147
|
| undefined
|
|
59148
|
+
/** Metadata for an Alertify sensor. */
|
|
59149
|
+
alertify_metadata?:
|
|
59150
|
+
| (
|
|
59151
|
+
| {
|
|
59152
|
+
/** Device ID reported by Alertify. */
|
|
59153
|
+
device_id?: (string | undefined) | undefined
|
|
59154
|
+
/** Device name, as set in the Alertify dashboard. */
|
|
59155
|
+
device_name?: (string | undefined) | undefined
|
|
59156
|
+
/** ID of the Alertify unit where the device is installed. */
|
|
59157
|
+
unit_id?: (string | undefined) | undefined
|
|
59158
|
+
/** Name of the Alertify unit where the device is installed. */
|
|
59159
|
+
unit_name?: (string | undefined) | undefined
|
|
59160
|
+
/** ID of the Alertify building that contains the unit. */
|
|
59161
|
+
building_id?: ((string | null) | undefined) | undefined
|
|
59162
|
+
}
|
|
59163
|
+
| undefined
|
|
59164
|
+
)
|
|
59165
|
+
| undefined
|
|
59139
59166
|
/** Metadata for a UniFi Protect camera. */
|
|
59140
59167
|
unifi_protect_metadata?:
|
|
59141
59168
|
| (
|
|
@@ -59434,11 +59461,11 @@ export type Routes = {
|
|
|
59434
59461
|
| undefined
|
|
59435
59462
|
} & {
|
|
59436
59463
|
/** Reported temperature in °F. */
|
|
59437
|
-
temperature_fahrenheit?:
|
|
59464
|
+
temperature_fahrenheit?: number | undefined
|
|
59438
59465
|
/** Reported temperature in °C. */
|
|
59439
|
-
temperature_celsius?:
|
|
59466
|
+
temperature_celsius?: number | undefined
|
|
59440
59467
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
59441
|
-
relative_humidity?:
|
|
59468
|
+
relative_humidity?: number | undefined
|
|
59442
59469
|
/** HVAC mode settings that the thermostat supports. */
|
|
59443
59470
|
available_hvac_mode_settings?:
|
|
59444
59471
|
('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined
|
|
@@ -60251,6 +60278,63 @@ export type Routes = {
|
|
|
60251
60278
|
image_url?: string | undefined
|
|
60252
60279
|
}
|
|
60253
60280
|
| undefined
|
|
60281
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
60282
|
+
temperature_celsius?: number | undefined
|
|
60283
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
60284
|
+
temperature_fahrenheit?: number | undefined
|
|
60285
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
60286
|
+
relative_humidity?: number | undefined
|
|
60287
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
60288
|
+
noise_level_decibels?: number | undefined
|
|
60289
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
60290
|
+
noise_level_nrs?: number | undefined
|
|
60291
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
60292
|
+
co2_ppm?: number | undefined
|
|
60293
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
60294
|
+
co_ppm?: number | undefined
|
|
60295
|
+
/** Air quality index, if the device measures it. */
|
|
60296
|
+
air_quality_index?: number | undefined
|
|
60297
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
60298
|
+
mold_risk_level?: string | undefined
|
|
60299
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
60300
|
+
is_occupied?: boolean | undefined
|
|
60301
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
60302
|
+
occupant_count?: number | undefined
|
|
60303
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
60304
|
+
is_smoking_detected?: boolean | undefined
|
|
60305
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
60306
|
+
named_sensors?:
|
|
60307
|
+
| {
|
|
60308
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
60309
|
+
sensor_name: string
|
|
60310
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
60311
|
+
display_name: string
|
|
60312
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
60313
|
+
temperature_celsius?: number | undefined
|
|
60314
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
60315
|
+
temperature_fahrenheit?: number | undefined
|
|
60316
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
60317
|
+
relative_humidity?: number | undefined
|
|
60318
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
60319
|
+
noise_level_decibels?: number | undefined
|
|
60320
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
60321
|
+
noise_level_nrs?: number | undefined
|
|
60322
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
60323
|
+
co2_ppm?: number | undefined
|
|
60324
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
60325
|
+
co_ppm?: number | undefined
|
|
60326
|
+
/** Air quality index, if the device measures it. */
|
|
60327
|
+
air_quality_index?: number | undefined
|
|
60328
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
60329
|
+
mold_risk_level?: string | undefined
|
|
60330
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
60331
|
+
is_occupied?: boolean | undefined
|
|
60332
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
60333
|
+
occupant_count?: number | undefined
|
|
60334
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
60335
|
+
is_smoking_detected?: boolean | undefined
|
|
60336
|
+
}[]
|
|
60337
|
+
| undefined
|
|
60254
60338
|
/** Indicates whether the device supports remote unlocking. */
|
|
60255
60339
|
can_remotely_unlock?: boolean | undefined
|
|
60256
60340
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -60389,6 +60473,7 @@ export type Routes = {
|
|
|
60389
60473
|
| 'unifi_protect_camera'
|
|
60390
60474
|
)
|
|
60391
60475
|
| 'sonos_speaker'
|
|
60476
|
+
| 'alertify_sensor'
|
|
60392
60477
|
)
|
|
60393
60478
|
| undefined
|
|
60394
60479
|
/** Array of device types for which you want to list devices. */
|
|
@@ -60450,6 +60535,7 @@ export type Routes = {
|
|
|
60450
60535
|
| 'unifi_protect_camera'
|
|
60451
60536
|
)
|
|
60452
60537
|
| 'sonos_speaker'
|
|
60538
|
+
| 'alertify_sensor'
|
|
60453
60539
|
)[]
|
|
60454
60540
|
| undefined
|
|
60455
60541
|
/** Manufacturer for which you want to list devices. */
|
|
@@ -60506,6 +60592,7 @@ export type Routes = {
|
|
|
60506
60592
|
| 'reolink'
|
|
60507
60593
|
| 'unifi_protect'
|
|
60508
60594
|
| 'yale_connect'
|
|
60595
|
+
| 'alertify'
|
|
60509
60596
|
| 'ical'
|
|
60510
60597
|
| 'lodgify'
|
|
60511
60598
|
| 'hostaway'
|
|
@@ -60675,6 +60762,7 @@ export type Routes = {
|
|
|
60675
60762
|
| 'unifi_protect_camera'
|
|
60676
60763
|
)
|
|
60677
60764
|
| 'sonos_speaker'
|
|
60765
|
+
| 'alertify_sensor'
|
|
60678
60766
|
/** IDs of the spaces the device is in. */
|
|
60679
60767
|
space_ids: string[]
|
|
60680
60768
|
/** Optional nickname to describe the device, settable through Seam. */
|
|
@@ -60783,58 +60871,9 @@ export type Routes = {
|
|
|
60783
60871
|
* @deprecated use offline_access_codes_enabled*/
|
|
60784
60872
|
supports_offline_access_codes?: boolean | undefined
|
|
60785
60873
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
60786
|
-
noise_level_decibels?:
|
|
60874
|
+
noise_level_decibels?: number | undefined
|
|
60787
60875
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
60788
60876
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
60789
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
60790
|
-
noise_level_nrs?: (number | null) | undefined
|
|
60791
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
60792
|
-
co2_ppm?: (number | null) | undefined
|
|
60793
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
60794
|
-
co_ppm?: (number | null) | undefined
|
|
60795
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
60796
|
-
air_quality_index?: (number | null) | undefined
|
|
60797
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
60798
|
-
mold_risk_level?: (string | null) | undefined
|
|
60799
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
60800
|
-
is_occupied?: (boolean | null) | undefined
|
|
60801
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
60802
|
-
occupant_count?: (number | null) | undefined
|
|
60803
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
60804
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
60805
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
60806
|
-
named_sensors?:
|
|
60807
|
-
| {
|
|
60808
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
60809
|
-
sensor_name: string
|
|
60810
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
60811
|
-
display_name: string
|
|
60812
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
60813
|
-
temperature_celsius?: (number | null) | undefined
|
|
60814
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
60815
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
60816
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
60817
|
-
relative_humidity?: (number | null) | undefined
|
|
60818
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
60819
|
-
noise_level_decibels?: (number | null) | undefined
|
|
60820
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
60821
|
-
noise_level_nrs?: (number | null) | undefined
|
|
60822
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
60823
|
-
co2_ppm?: (number | null) | undefined
|
|
60824
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
60825
|
-
co_ppm?: (number | null) | undefined
|
|
60826
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
60827
|
-
air_quality_index?: (number | null) | undefined
|
|
60828
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
60829
|
-
mold_risk_level?: (string | null) | undefined
|
|
60830
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
60831
|
-
is_occupied?: (boolean | null) | undefined
|
|
60832
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
60833
|
-
occupant_count?: (number | null) | undefined
|
|
60834
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
60835
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
60836
|
-
}[]
|
|
60837
|
-
| undefined
|
|
60838
60877
|
} & {
|
|
60839
60878
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
60840
60879
|
assa_abloy_credential_service_metadata?:
|
|
@@ -61576,6 +61615,24 @@ export type Routes = {
|
|
|
61576
61615
|
| undefined
|
|
61577
61616
|
)
|
|
61578
61617
|
| undefined
|
|
61618
|
+
/** Metadata for an Alertify sensor. */
|
|
61619
|
+
alertify_metadata?:
|
|
61620
|
+
| (
|
|
61621
|
+
| {
|
|
61622
|
+
/** Device ID reported by Alertify. */
|
|
61623
|
+
device_id?: (string | undefined) | undefined
|
|
61624
|
+
/** Device name, as set in the Alertify dashboard. */
|
|
61625
|
+
device_name?: (string | undefined) | undefined
|
|
61626
|
+
/** ID of the Alertify unit where the device is installed. */
|
|
61627
|
+
unit_id?: (string | undefined) | undefined
|
|
61628
|
+
/** Name of the Alertify unit where the device is installed. */
|
|
61629
|
+
unit_name?: (string | undefined) | undefined
|
|
61630
|
+
/** ID of the Alertify building that contains the unit. */
|
|
61631
|
+
building_id?: ((string | null) | undefined) | undefined
|
|
61632
|
+
}
|
|
61633
|
+
| undefined
|
|
61634
|
+
)
|
|
61635
|
+
| undefined
|
|
61579
61636
|
/** Metadata for a UniFi Protect camera. */
|
|
61580
61637
|
unifi_protect_metadata?:
|
|
61581
61638
|
| (
|
|
@@ -61874,11 +61931,11 @@ export type Routes = {
|
|
|
61874
61931
|
| undefined
|
|
61875
61932
|
} & {
|
|
61876
61933
|
/** Reported temperature in °F. */
|
|
61877
|
-
temperature_fahrenheit?:
|
|
61934
|
+
temperature_fahrenheit?: number | undefined
|
|
61878
61935
|
/** Reported temperature in °C. */
|
|
61879
|
-
temperature_celsius?:
|
|
61936
|
+
temperature_celsius?: number | undefined
|
|
61880
61937
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
61881
|
-
relative_humidity?:
|
|
61938
|
+
relative_humidity?: number | undefined
|
|
61882
61939
|
/** HVAC mode settings that the thermostat supports. */
|
|
61883
61940
|
available_hvac_mode_settings?:
|
|
61884
61941
|
('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined
|
|
@@ -62691,6 +62748,63 @@ export type Routes = {
|
|
|
62691
62748
|
image_url?: string | undefined
|
|
62692
62749
|
}
|
|
62693
62750
|
| undefined
|
|
62751
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
62752
|
+
temperature_celsius?: number | undefined
|
|
62753
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
62754
|
+
temperature_fahrenheit?: number | undefined
|
|
62755
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
62756
|
+
relative_humidity?: number | undefined
|
|
62757
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
62758
|
+
noise_level_decibels?: number | undefined
|
|
62759
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
62760
|
+
noise_level_nrs?: number | undefined
|
|
62761
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
62762
|
+
co2_ppm?: number | undefined
|
|
62763
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
62764
|
+
co_ppm?: number | undefined
|
|
62765
|
+
/** Air quality index, if the device measures it. */
|
|
62766
|
+
air_quality_index?: number | undefined
|
|
62767
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
62768
|
+
mold_risk_level?: string | undefined
|
|
62769
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
62770
|
+
is_occupied?: boolean | undefined
|
|
62771
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
62772
|
+
occupant_count?: number | undefined
|
|
62773
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
62774
|
+
is_smoking_detected?: boolean | undefined
|
|
62775
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
62776
|
+
named_sensors?:
|
|
62777
|
+
| {
|
|
62778
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
62779
|
+
sensor_name: string
|
|
62780
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
62781
|
+
display_name: string
|
|
62782
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
62783
|
+
temperature_celsius?: number | undefined
|
|
62784
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
62785
|
+
temperature_fahrenheit?: number | undefined
|
|
62786
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
62787
|
+
relative_humidity?: number | undefined
|
|
62788
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
62789
|
+
noise_level_decibels?: number | undefined
|
|
62790
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
62791
|
+
noise_level_nrs?: number | undefined
|
|
62792
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
62793
|
+
co2_ppm?: number | undefined
|
|
62794
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
62795
|
+
co_ppm?: number | undefined
|
|
62796
|
+
/** Air quality index, if the device measures it. */
|
|
62797
|
+
air_quality_index?: number | undefined
|
|
62798
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
62799
|
+
mold_risk_level?: string | undefined
|
|
62800
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
62801
|
+
is_occupied?: boolean | undefined
|
|
62802
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
62803
|
+
occupant_count?: number | undefined
|
|
62804
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
62805
|
+
is_smoking_detected?: boolean | undefined
|
|
62806
|
+
}[]
|
|
62807
|
+
| undefined
|
|
62694
62808
|
/** Indicates whether the device supports remote unlocking. */
|
|
62695
62809
|
can_remotely_unlock?: boolean | undefined
|
|
62696
62810
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -62854,6 +62968,7 @@ export type Routes = {
|
|
|
62854
62968
|
| 'reolink'
|
|
62855
62969
|
| 'unifi_protect'
|
|
62856
62970
|
| 'yale_connect'
|
|
62971
|
+
| 'alertify'
|
|
62857
62972
|
| 'ical'
|
|
62858
62973
|
| 'lodgify'
|
|
62859
62974
|
| 'hostaway'
|
|
@@ -64421,6 +64536,7 @@ export type Routes = {
|
|
|
64421
64536
|
| 'unifi_protect_camera'
|
|
64422
64537
|
)
|
|
64423
64538
|
| 'sonos_speaker'
|
|
64539
|
+
| 'alertify_sensor'
|
|
64424
64540
|
/** Unique identifier for the account associated with the device. */
|
|
64425
64541
|
connected_account_id: string
|
|
64426
64542
|
/** Location information for the device. */
|
|
@@ -65069,6 +65185,7 @@ export type Routes = {
|
|
|
65069
65185
|
| 'unifi_protect_camera'
|
|
65070
65186
|
)
|
|
65071
65187
|
| 'sonos_speaker'
|
|
65188
|
+
| 'alertify_sensor'
|
|
65072
65189
|
)
|
|
65073
65190
|
| undefined
|
|
65074
65191
|
/** Array of device types for which you want to list devices. */
|
|
@@ -65130,6 +65247,7 @@ export type Routes = {
|
|
|
65130
65247
|
| 'unifi_protect_camera'
|
|
65131
65248
|
)
|
|
65132
65249
|
| 'sonos_speaker'
|
|
65250
|
+
| 'alertify_sensor'
|
|
65133
65251
|
)[]
|
|
65134
65252
|
| undefined
|
|
65135
65253
|
/** Manufacturer for which you want to list devices. */
|
|
@@ -65186,6 +65304,7 @@ export type Routes = {
|
|
|
65186
65304
|
| 'reolink'
|
|
65187
65305
|
| 'unifi_protect'
|
|
65188
65306
|
| 'yale_connect'
|
|
65307
|
+
| 'alertify'
|
|
65189
65308
|
| 'ical'
|
|
65190
65309
|
| 'lodgify'
|
|
65191
65310
|
| 'hostaway'
|
|
@@ -65342,6 +65461,7 @@ export type Routes = {
|
|
|
65342
65461
|
| 'unifi_protect_camera'
|
|
65343
65462
|
)
|
|
65344
65463
|
| 'sonos_speaker'
|
|
65464
|
+
| 'alertify_sensor'
|
|
65345
65465
|
/** Unique identifier for the account associated with the device. */
|
|
65346
65466
|
connected_account_id: string
|
|
65347
65467
|
/** Location information for the device. */
|
|
@@ -77473,6 +77593,7 @@ export type Routes = {
|
|
|
77473
77593
|
| 'unifi_protect_camera'
|
|
77474
77594
|
)
|
|
77475
77595
|
| 'sonos_speaker'
|
|
77596
|
+
| 'alertify_sensor'
|
|
77476
77597
|
/** IDs of the spaces the device is in. */
|
|
77477
77598
|
space_ids: string[]
|
|
77478
77599
|
/** Optional nickname to describe the device, settable through Seam. */
|
|
@@ -77581,58 +77702,9 @@ export type Routes = {
|
|
|
77581
77702
|
* @deprecated use offline_access_codes_enabled*/
|
|
77582
77703
|
supports_offline_access_codes?: boolean | undefined
|
|
77583
77704
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
77584
|
-
noise_level_decibels?:
|
|
77705
|
+
noise_level_decibels?: number | undefined
|
|
77585
77706
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
77586
77707
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
77587
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
77588
|
-
noise_level_nrs?: (number | null) | undefined
|
|
77589
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
77590
|
-
co2_ppm?: (number | null) | undefined
|
|
77591
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
77592
|
-
co_ppm?: (number | null) | undefined
|
|
77593
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
77594
|
-
air_quality_index?: (number | null) | undefined
|
|
77595
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
77596
|
-
mold_risk_level?: (string | null) | undefined
|
|
77597
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
77598
|
-
is_occupied?: (boolean | null) | undefined
|
|
77599
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
77600
|
-
occupant_count?: (number | null) | undefined
|
|
77601
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
77602
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
77603
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
77604
|
-
named_sensors?:
|
|
77605
|
-
| {
|
|
77606
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
77607
|
-
sensor_name: string
|
|
77608
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
77609
|
-
display_name: string
|
|
77610
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
77611
|
-
temperature_celsius?: (number | null) | undefined
|
|
77612
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
77613
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
77614
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
77615
|
-
relative_humidity?: (number | null) | undefined
|
|
77616
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
77617
|
-
noise_level_decibels?: (number | null) | undefined
|
|
77618
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
77619
|
-
noise_level_nrs?: (number | null) | undefined
|
|
77620
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
77621
|
-
co2_ppm?: (number | null) | undefined
|
|
77622
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
77623
|
-
co_ppm?: (number | null) | undefined
|
|
77624
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
77625
|
-
air_quality_index?: (number | null) | undefined
|
|
77626
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
77627
|
-
mold_risk_level?: (string | null) | undefined
|
|
77628
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
77629
|
-
is_occupied?: (boolean | null) | undefined
|
|
77630
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
77631
|
-
occupant_count?: (number | null) | undefined
|
|
77632
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
77633
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
77634
|
-
}[]
|
|
77635
|
-
| undefined
|
|
77636
77708
|
} & {
|
|
77637
77709
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
77638
77710
|
assa_abloy_credential_service_metadata?:
|
|
@@ -78374,6 +78446,24 @@ export type Routes = {
|
|
|
78374
78446
|
| undefined
|
|
78375
78447
|
)
|
|
78376
78448
|
| undefined
|
|
78449
|
+
/** Metadata for an Alertify sensor. */
|
|
78450
|
+
alertify_metadata?:
|
|
78451
|
+
| (
|
|
78452
|
+
| {
|
|
78453
|
+
/** Device ID reported by Alertify. */
|
|
78454
|
+
device_id?: (string | undefined) | undefined
|
|
78455
|
+
/** Device name, as set in the Alertify dashboard. */
|
|
78456
|
+
device_name?: (string | undefined) | undefined
|
|
78457
|
+
/** ID of the Alertify unit where the device is installed. */
|
|
78458
|
+
unit_id?: (string | undefined) | undefined
|
|
78459
|
+
/** Name of the Alertify unit where the device is installed. */
|
|
78460
|
+
unit_name?: (string | undefined) | undefined
|
|
78461
|
+
/** ID of the Alertify building that contains the unit. */
|
|
78462
|
+
building_id?: ((string | null) | undefined) | undefined
|
|
78463
|
+
}
|
|
78464
|
+
| undefined
|
|
78465
|
+
)
|
|
78466
|
+
| undefined
|
|
78377
78467
|
/** Metadata for a UniFi Protect camera. */
|
|
78378
78468
|
unifi_protect_metadata?:
|
|
78379
78469
|
| (
|
|
@@ -78672,11 +78762,11 @@ export type Routes = {
|
|
|
78672
78762
|
| undefined
|
|
78673
78763
|
} & {
|
|
78674
78764
|
/** Reported temperature in °F. */
|
|
78675
|
-
temperature_fahrenheit?:
|
|
78765
|
+
temperature_fahrenheit?: number | undefined
|
|
78676
78766
|
/** Reported temperature in °C. */
|
|
78677
|
-
temperature_celsius?:
|
|
78767
|
+
temperature_celsius?: number | undefined
|
|
78678
78768
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
78679
|
-
relative_humidity?:
|
|
78769
|
+
relative_humidity?: number | undefined
|
|
78680
78770
|
/** HVAC mode settings that the thermostat supports. */
|
|
78681
78771
|
available_hvac_mode_settings?:
|
|
78682
78772
|
('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined
|
|
@@ -79489,6 +79579,63 @@ export type Routes = {
|
|
|
79489
79579
|
image_url?: string | undefined
|
|
79490
79580
|
}
|
|
79491
79581
|
| undefined
|
|
79582
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
79583
|
+
temperature_celsius?: number | undefined
|
|
79584
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
79585
|
+
temperature_fahrenheit?: number | undefined
|
|
79586
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
79587
|
+
relative_humidity?: number | undefined
|
|
79588
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
79589
|
+
noise_level_decibels?: number | undefined
|
|
79590
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
79591
|
+
noise_level_nrs?: number | undefined
|
|
79592
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
79593
|
+
co2_ppm?: number | undefined
|
|
79594
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
79595
|
+
co_ppm?: number | undefined
|
|
79596
|
+
/** Air quality index, if the device measures it. */
|
|
79597
|
+
air_quality_index?: number | undefined
|
|
79598
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
79599
|
+
mold_risk_level?: string | undefined
|
|
79600
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
79601
|
+
is_occupied?: boolean | undefined
|
|
79602
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
79603
|
+
occupant_count?: number | undefined
|
|
79604
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
79605
|
+
is_smoking_detected?: boolean | undefined
|
|
79606
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
79607
|
+
named_sensors?:
|
|
79608
|
+
| {
|
|
79609
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
79610
|
+
sensor_name: string
|
|
79611
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
79612
|
+
display_name: string
|
|
79613
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
79614
|
+
temperature_celsius?: number | undefined
|
|
79615
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
79616
|
+
temperature_fahrenheit?: number | undefined
|
|
79617
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
79618
|
+
relative_humidity?: number | undefined
|
|
79619
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
79620
|
+
noise_level_decibels?: number | undefined
|
|
79621
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
79622
|
+
noise_level_nrs?: number | undefined
|
|
79623
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
79624
|
+
co2_ppm?: number | undefined
|
|
79625
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
79626
|
+
co_ppm?: number | undefined
|
|
79627
|
+
/** Air quality index, if the device measures it. */
|
|
79628
|
+
air_quality_index?: number | undefined
|
|
79629
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
79630
|
+
mold_risk_level?: string | undefined
|
|
79631
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
79632
|
+
is_occupied?: boolean | undefined
|
|
79633
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
79634
|
+
occupant_count?: number | undefined
|
|
79635
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
79636
|
+
is_smoking_detected?: boolean | undefined
|
|
79637
|
+
}[]
|
|
79638
|
+
| undefined
|
|
79492
79639
|
/** Indicates whether the device supports remote unlocking. */
|
|
79493
79640
|
can_remotely_unlock?: boolean | undefined
|
|
79494
79641
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -79613,6 +79760,7 @@ export type Routes = {
|
|
|
79613
79760
|
| 'unifi_protect_camera'
|
|
79614
79761
|
)
|
|
79615
79762
|
| 'sonos_speaker'
|
|
79763
|
+
| 'alertify_sensor'
|
|
79616
79764
|
/** IDs of the spaces the device is in. */
|
|
79617
79765
|
space_ids: string[]
|
|
79618
79766
|
/** Optional nickname to describe the device, settable through Seam. */
|
|
@@ -79721,58 +79869,9 @@ export type Routes = {
|
|
|
79721
79869
|
* @deprecated use offline_access_codes_enabled*/
|
|
79722
79870
|
supports_offline_access_codes?: boolean | undefined
|
|
79723
79871
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
79724
|
-
noise_level_decibels?:
|
|
79872
|
+
noise_level_decibels?: number | undefined
|
|
79725
79873
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
79726
79874
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
79727
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
79728
|
-
noise_level_nrs?: (number | null) | undefined
|
|
79729
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
79730
|
-
co2_ppm?: (number | null) | undefined
|
|
79731
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
79732
|
-
co_ppm?: (number | null) | undefined
|
|
79733
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
79734
|
-
air_quality_index?: (number | null) | undefined
|
|
79735
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
79736
|
-
mold_risk_level?: (string | null) | undefined
|
|
79737
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
79738
|
-
is_occupied?: (boolean | null) | undefined
|
|
79739
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
79740
|
-
occupant_count?: (number | null) | undefined
|
|
79741
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
79742
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
79743
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
79744
|
-
named_sensors?:
|
|
79745
|
-
| {
|
|
79746
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
79747
|
-
sensor_name: string
|
|
79748
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
79749
|
-
display_name: string
|
|
79750
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
79751
|
-
temperature_celsius?: (number | null) | undefined
|
|
79752
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
79753
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
79754
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
79755
|
-
relative_humidity?: (number | null) | undefined
|
|
79756
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
79757
|
-
noise_level_decibels?: (number | null) | undefined
|
|
79758
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
79759
|
-
noise_level_nrs?: (number | null) | undefined
|
|
79760
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
79761
|
-
co2_ppm?: (number | null) | undefined
|
|
79762
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
79763
|
-
co_ppm?: (number | null) | undefined
|
|
79764
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
79765
|
-
air_quality_index?: (number | null) | undefined
|
|
79766
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
79767
|
-
mold_risk_level?: (string | null) | undefined
|
|
79768
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
79769
|
-
is_occupied?: (boolean | null) | undefined
|
|
79770
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
79771
|
-
occupant_count?: (number | null) | undefined
|
|
79772
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
79773
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
79774
|
-
}[]
|
|
79775
|
-
| undefined
|
|
79776
79875
|
} & {
|
|
79777
79876
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
79778
79877
|
assa_abloy_credential_service_metadata?:
|
|
@@ -80514,6 +80613,24 @@ export type Routes = {
|
|
|
80514
80613
|
| undefined
|
|
80515
80614
|
)
|
|
80516
80615
|
| undefined
|
|
80616
|
+
/** Metadata for an Alertify sensor. */
|
|
80617
|
+
alertify_metadata?:
|
|
80618
|
+
| (
|
|
80619
|
+
| {
|
|
80620
|
+
/** Device ID reported by Alertify. */
|
|
80621
|
+
device_id?: (string | undefined) | undefined
|
|
80622
|
+
/** Device name, as set in the Alertify dashboard. */
|
|
80623
|
+
device_name?: (string | undefined) | undefined
|
|
80624
|
+
/** ID of the Alertify unit where the device is installed. */
|
|
80625
|
+
unit_id?: (string | undefined) | undefined
|
|
80626
|
+
/** Name of the Alertify unit where the device is installed. */
|
|
80627
|
+
unit_name?: (string | undefined) | undefined
|
|
80628
|
+
/** ID of the Alertify building that contains the unit. */
|
|
80629
|
+
building_id?: ((string | null) | undefined) | undefined
|
|
80630
|
+
}
|
|
80631
|
+
| undefined
|
|
80632
|
+
)
|
|
80633
|
+
| undefined
|
|
80517
80634
|
/** Metadata for a UniFi Protect camera. */
|
|
80518
80635
|
unifi_protect_metadata?:
|
|
80519
80636
|
| (
|
|
@@ -80812,11 +80929,11 @@ export type Routes = {
|
|
|
80812
80929
|
| undefined
|
|
80813
80930
|
} & {
|
|
80814
80931
|
/** Reported temperature in °F. */
|
|
80815
|
-
temperature_fahrenheit?:
|
|
80932
|
+
temperature_fahrenheit?: number | undefined
|
|
80816
80933
|
/** Reported temperature in °C. */
|
|
80817
|
-
temperature_celsius?:
|
|
80934
|
+
temperature_celsius?: number | undefined
|
|
80818
80935
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
80819
|
-
relative_humidity?:
|
|
80936
|
+
relative_humidity?: number | undefined
|
|
80820
80937
|
/** HVAC mode settings that the thermostat supports. */
|
|
80821
80938
|
available_hvac_mode_settings?:
|
|
80822
80939
|
('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined
|
|
@@ -81629,6 +81746,63 @@ export type Routes = {
|
|
|
81629
81746
|
image_url?: string | undefined
|
|
81630
81747
|
}
|
|
81631
81748
|
| undefined
|
|
81749
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
81750
|
+
temperature_celsius?: number | undefined
|
|
81751
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
81752
|
+
temperature_fahrenheit?: number | undefined
|
|
81753
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
81754
|
+
relative_humidity?: number | undefined
|
|
81755
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
81756
|
+
noise_level_decibels?: number | undefined
|
|
81757
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
81758
|
+
noise_level_nrs?: number | undefined
|
|
81759
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
81760
|
+
co2_ppm?: number | undefined
|
|
81761
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
81762
|
+
co_ppm?: number | undefined
|
|
81763
|
+
/** Air quality index, if the device measures it. */
|
|
81764
|
+
air_quality_index?: number | undefined
|
|
81765
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
81766
|
+
mold_risk_level?: string | undefined
|
|
81767
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
81768
|
+
is_occupied?: boolean | undefined
|
|
81769
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
81770
|
+
occupant_count?: number | undefined
|
|
81771
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
81772
|
+
is_smoking_detected?: boolean | undefined
|
|
81773
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
81774
|
+
named_sensors?:
|
|
81775
|
+
| {
|
|
81776
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
81777
|
+
sensor_name: string
|
|
81778
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
81779
|
+
display_name: string
|
|
81780
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
81781
|
+
temperature_celsius?: number | undefined
|
|
81782
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
81783
|
+
temperature_fahrenheit?: number | undefined
|
|
81784
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
81785
|
+
relative_humidity?: number | undefined
|
|
81786
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
81787
|
+
noise_level_decibels?: number | undefined
|
|
81788
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
81789
|
+
noise_level_nrs?: number | undefined
|
|
81790
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
81791
|
+
co2_ppm?: number | undefined
|
|
81792
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
81793
|
+
co_ppm?: number | undefined
|
|
81794
|
+
/** Air quality index, if the device measures it. */
|
|
81795
|
+
air_quality_index?: number | undefined
|
|
81796
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
81797
|
+
mold_risk_level?: string | undefined
|
|
81798
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
81799
|
+
is_occupied?: boolean | undefined
|
|
81800
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
81801
|
+
occupant_count?: number | undefined
|
|
81802
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
81803
|
+
is_smoking_detected?: boolean | undefined
|
|
81804
|
+
}[]
|
|
81805
|
+
| undefined
|
|
81632
81806
|
/** Indicates whether the device supports remote unlocking. */
|
|
81633
81807
|
can_remotely_unlock?: boolean | undefined
|
|
81634
81808
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -81891,6 +82065,7 @@ export type Routes = {
|
|
|
81891
82065
|
| 'unifi_protect_camera'
|
|
81892
82066
|
)
|
|
81893
82067
|
| 'sonos_speaker'
|
|
82068
|
+
| 'alertify_sensor'
|
|
81894
82069
|
/** IDs of the spaces the device is in. */
|
|
81895
82070
|
space_ids: string[]
|
|
81896
82071
|
/** Optional nickname to describe the device, settable through Seam. */
|
|
@@ -81999,58 +82174,9 @@ export type Routes = {
|
|
|
81999
82174
|
* @deprecated use offline_access_codes_enabled*/
|
|
82000
82175
|
supports_offline_access_codes?: boolean | undefined
|
|
82001
82176
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
82002
|
-
noise_level_decibels?:
|
|
82177
|
+
noise_level_decibels?: number | undefined
|
|
82003
82178
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
82004
82179
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
82005
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
82006
|
-
noise_level_nrs?: (number | null) | undefined
|
|
82007
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
82008
|
-
co2_ppm?: (number | null) | undefined
|
|
82009
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
82010
|
-
co_ppm?: (number | null) | undefined
|
|
82011
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
82012
|
-
air_quality_index?: (number | null) | undefined
|
|
82013
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
82014
|
-
mold_risk_level?: (string | null) | undefined
|
|
82015
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
82016
|
-
is_occupied?: (boolean | null) | undefined
|
|
82017
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
82018
|
-
occupant_count?: (number | null) | undefined
|
|
82019
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
82020
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
82021
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
82022
|
-
named_sensors?:
|
|
82023
|
-
| {
|
|
82024
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
82025
|
-
sensor_name: string
|
|
82026
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
82027
|
-
display_name: string
|
|
82028
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
82029
|
-
temperature_celsius?: (number | null) | undefined
|
|
82030
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
82031
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
82032
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
82033
|
-
relative_humidity?: (number | null) | undefined
|
|
82034
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
82035
|
-
noise_level_decibels?: (number | null) | undefined
|
|
82036
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
82037
|
-
noise_level_nrs?: (number | null) | undefined
|
|
82038
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
82039
|
-
co2_ppm?: (number | null) | undefined
|
|
82040
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
82041
|
-
co_ppm?: (number | null) | undefined
|
|
82042
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
82043
|
-
air_quality_index?: (number | null) | undefined
|
|
82044
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
82045
|
-
mold_risk_level?: (string | null) | undefined
|
|
82046
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
82047
|
-
is_occupied?: (boolean | null) | undefined
|
|
82048
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
82049
|
-
occupant_count?: (number | null) | undefined
|
|
82050
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
82051
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
82052
|
-
}[]
|
|
82053
|
-
| undefined
|
|
82054
82180
|
} & {
|
|
82055
82181
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
82056
82182
|
assa_abloy_credential_service_metadata?:
|
|
@@ -82792,6 +82918,24 @@ export type Routes = {
|
|
|
82792
82918
|
| undefined
|
|
82793
82919
|
)
|
|
82794
82920
|
| undefined
|
|
82921
|
+
/** Metadata for an Alertify sensor. */
|
|
82922
|
+
alertify_metadata?:
|
|
82923
|
+
| (
|
|
82924
|
+
| {
|
|
82925
|
+
/** Device ID reported by Alertify. */
|
|
82926
|
+
device_id?: (string | undefined) | undefined
|
|
82927
|
+
/** Device name, as set in the Alertify dashboard. */
|
|
82928
|
+
device_name?: (string | undefined) | undefined
|
|
82929
|
+
/** ID of the Alertify unit where the device is installed. */
|
|
82930
|
+
unit_id?: (string | undefined) | undefined
|
|
82931
|
+
/** Name of the Alertify unit where the device is installed. */
|
|
82932
|
+
unit_name?: (string | undefined) | undefined
|
|
82933
|
+
/** ID of the Alertify building that contains the unit. */
|
|
82934
|
+
building_id?: ((string | null) | undefined) | undefined
|
|
82935
|
+
}
|
|
82936
|
+
| undefined
|
|
82937
|
+
)
|
|
82938
|
+
| undefined
|
|
82795
82939
|
/** Metadata for a UniFi Protect camera. */
|
|
82796
82940
|
unifi_protect_metadata?:
|
|
82797
82941
|
| (
|
|
@@ -83090,11 +83234,11 @@ export type Routes = {
|
|
|
83090
83234
|
| undefined
|
|
83091
83235
|
} & {
|
|
83092
83236
|
/** Reported temperature in °F. */
|
|
83093
|
-
temperature_fahrenheit?:
|
|
83237
|
+
temperature_fahrenheit?: number | undefined
|
|
83094
83238
|
/** Reported temperature in °C. */
|
|
83095
|
-
temperature_celsius?:
|
|
83239
|
+
temperature_celsius?: number | undefined
|
|
83096
83240
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
83097
|
-
relative_humidity?:
|
|
83241
|
+
relative_humidity?: number | undefined
|
|
83098
83242
|
/** HVAC mode settings that the thermostat supports. */
|
|
83099
83243
|
available_hvac_mode_settings?:
|
|
83100
83244
|
('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined
|
|
@@ -83907,6 +84051,63 @@ export type Routes = {
|
|
|
83907
84051
|
image_url?: string | undefined
|
|
83908
84052
|
}
|
|
83909
84053
|
| undefined
|
|
84054
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
84055
|
+
temperature_celsius?: number | undefined
|
|
84056
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
84057
|
+
temperature_fahrenheit?: number | undefined
|
|
84058
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
84059
|
+
relative_humidity?: number | undefined
|
|
84060
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
84061
|
+
noise_level_decibels?: number | undefined
|
|
84062
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
84063
|
+
noise_level_nrs?: number | undefined
|
|
84064
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
84065
|
+
co2_ppm?: number | undefined
|
|
84066
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
84067
|
+
co_ppm?: number | undefined
|
|
84068
|
+
/** Air quality index, if the device measures it. */
|
|
84069
|
+
air_quality_index?: number | undefined
|
|
84070
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
84071
|
+
mold_risk_level?: string | undefined
|
|
84072
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
84073
|
+
is_occupied?: boolean | undefined
|
|
84074
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
84075
|
+
occupant_count?: number | undefined
|
|
84076
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
84077
|
+
is_smoking_detected?: boolean | undefined
|
|
84078
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
84079
|
+
named_sensors?:
|
|
84080
|
+
| {
|
|
84081
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
84082
|
+
sensor_name: string
|
|
84083
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
84084
|
+
display_name: string
|
|
84085
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
84086
|
+
temperature_celsius?: number | undefined
|
|
84087
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
84088
|
+
temperature_fahrenheit?: number | undefined
|
|
84089
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
84090
|
+
relative_humidity?: number | undefined
|
|
84091
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
84092
|
+
noise_level_decibels?: number | undefined
|
|
84093
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
84094
|
+
noise_level_nrs?: number | undefined
|
|
84095
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
84096
|
+
co2_ppm?: number | undefined
|
|
84097
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
84098
|
+
co_ppm?: number | undefined
|
|
84099
|
+
/** Air quality index, if the device measures it. */
|
|
84100
|
+
air_quality_index?: number | undefined
|
|
84101
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
84102
|
+
mold_risk_level?: string | undefined
|
|
84103
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
84104
|
+
is_occupied?: boolean | undefined
|
|
84105
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
84106
|
+
occupant_count?: number | undefined
|
|
84107
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
84108
|
+
is_smoking_detected?: boolean | undefined
|
|
84109
|
+
}[]
|
|
84110
|
+
| undefined
|
|
83910
84111
|
/** Indicates whether the device supports remote unlocking. */
|
|
83911
84112
|
can_remotely_unlock?: boolean | undefined
|
|
83912
84113
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -84030,6 +84231,7 @@ export type Routes = {
|
|
|
84030
84231
|
| 'unifi_protect_camera'
|
|
84031
84232
|
)
|
|
84032
84233
|
| 'sonos_speaker'
|
|
84234
|
+
| 'alertify_sensor'
|
|
84033
84235
|
/** IDs of the spaces the device is in. */
|
|
84034
84236
|
space_ids: string[]
|
|
84035
84237
|
/** Optional nickname to describe the device, settable through Seam. */
|
|
@@ -84138,58 +84340,9 @@ export type Routes = {
|
|
|
84138
84340
|
* @deprecated use offline_access_codes_enabled*/
|
|
84139
84341
|
supports_offline_access_codes?: boolean | undefined
|
|
84140
84342
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
84141
|
-
noise_level_decibels?:
|
|
84343
|
+
noise_level_decibels?: number | undefined
|
|
84142
84344
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
84143
84345
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
84144
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
84145
|
-
noise_level_nrs?: (number | null) | undefined
|
|
84146
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
84147
|
-
co2_ppm?: (number | null) | undefined
|
|
84148
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
84149
|
-
co_ppm?: (number | null) | undefined
|
|
84150
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
84151
|
-
air_quality_index?: (number | null) | undefined
|
|
84152
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
84153
|
-
mold_risk_level?: (string | null) | undefined
|
|
84154
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
84155
|
-
is_occupied?: (boolean | null) | undefined
|
|
84156
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
84157
|
-
occupant_count?: (number | null) | undefined
|
|
84158
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
84159
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
84160
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
84161
|
-
named_sensors?:
|
|
84162
|
-
| {
|
|
84163
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
84164
|
-
sensor_name: string
|
|
84165
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
84166
|
-
display_name: string
|
|
84167
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
84168
|
-
temperature_celsius?: (number | null) | undefined
|
|
84169
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
84170
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
84171
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
84172
|
-
relative_humidity?: (number | null) | undefined
|
|
84173
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
84174
|
-
noise_level_decibels?: (number | null) | undefined
|
|
84175
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
84176
|
-
noise_level_nrs?: (number | null) | undefined
|
|
84177
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
84178
|
-
co2_ppm?: (number | null) | undefined
|
|
84179
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
84180
|
-
co_ppm?: (number | null) | undefined
|
|
84181
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
84182
|
-
air_quality_index?: (number | null) | undefined
|
|
84183
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
84184
|
-
mold_risk_level?: (string | null) | undefined
|
|
84185
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
84186
|
-
is_occupied?: (boolean | null) | undefined
|
|
84187
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
84188
|
-
occupant_count?: (number | null) | undefined
|
|
84189
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
84190
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
84191
|
-
}[]
|
|
84192
|
-
| undefined
|
|
84193
84346
|
} & {
|
|
84194
84347
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
84195
84348
|
assa_abloy_credential_service_metadata?:
|
|
@@ -84931,6 +85084,24 @@ export type Routes = {
|
|
|
84931
85084
|
| undefined
|
|
84932
85085
|
)
|
|
84933
85086
|
| undefined
|
|
85087
|
+
/** Metadata for an Alertify sensor. */
|
|
85088
|
+
alertify_metadata?:
|
|
85089
|
+
| (
|
|
85090
|
+
| {
|
|
85091
|
+
/** Device ID reported by Alertify. */
|
|
85092
|
+
device_id?: (string | undefined) | undefined
|
|
85093
|
+
/** Device name, as set in the Alertify dashboard. */
|
|
85094
|
+
device_name?: (string | undefined) | undefined
|
|
85095
|
+
/** ID of the Alertify unit where the device is installed. */
|
|
85096
|
+
unit_id?: (string | undefined) | undefined
|
|
85097
|
+
/** Name of the Alertify unit where the device is installed. */
|
|
85098
|
+
unit_name?: (string | undefined) | undefined
|
|
85099
|
+
/** ID of the Alertify building that contains the unit. */
|
|
85100
|
+
building_id?: ((string | null) | undefined) | undefined
|
|
85101
|
+
}
|
|
85102
|
+
| undefined
|
|
85103
|
+
)
|
|
85104
|
+
| undefined
|
|
84934
85105
|
/** Metadata for a UniFi Protect camera. */
|
|
84935
85106
|
unifi_protect_metadata?:
|
|
84936
85107
|
| (
|
|
@@ -85229,11 +85400,11 @@ export type Routes = {
|
|
|
85229
85400
|
| undefined
|
|
85230
85401
|
} & {
|
|
85231
85402
|
/** Reported temperature in °F. */
|
|
85232
|
-
temperature_fahrenheit?:
|
|
85403
|
+
temperature_fahrenheit?: number | undefined
|
|
85233
85404
|
/** Reported temperature in °C. */
|
|
85234
|
-
temperature_celsius?:
|
|
85405
|
+
temperature_celsius?: number | undefined
|
|
85235
85406
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
85236
|
-
relative_humidity?:
|
|
85407
|
+
relative_humidity?: number | undefined
|
|
85237
85408
|
/** HVAC mode settings that the thermostat supports. */
|
|
85238
85409
|
available_hvac_mode_settings?:
|
|
85239
85410
|
('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined
|
|
@@ -86046,6 +86217,63 @@ export type Routes = {
|
|
|
86046
86217
|
image_url?: string | undefined
|
|
86047
86218
|
}
|
|
86048
86219
|
| undefined
|
|
86220
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
86221
|
+
temperature_celsius?: number | undefined
|
|
86222
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
86223
|
+
temperature_fahrenheit?: number | undefined
|
|
86224
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
86225
|
+
relative_humidity?: number | undefined
|
|
86226
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
86227
|
+
noise_level_decibels?: number | undefined
|
|
86228
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
86229
|
+
noise_level_nrs?: number | undefined
|
|
86230
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
86231
|
+
co2_ppm?: number | undefined
|
|
86232
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
86233
|
+
co_ppm?: number | undefined
|
|
86234
|
+
/** Air quality index, if the device measures it. */
|
|
86235
|
+
air_quality_index?: number | undefined
|
|
86236
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
86237
|
+
mold_risk_level?: string | undefined
|
|
86238
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
86239
|
+
is_occupied?: boolean | undefined
|
|
86240
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
86241
|
+
occupant_count?: number | undefined
|
|
86242
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
86243
|
+
is_smoking_detected?: boolean | undefined
|
|
86244
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
86245
|
+
named_sensors?:
|
|
86246
|
+
| {
|
|
86247
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
86248
|
+
sensor_name: string
|
|
86249
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
86250
|
+
display_name: string
|
|
86251
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
86252
|
+
temperature_celsius?: number | undefined
|
|
86253
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
86254
|
+
temperature_fahrenheit?: number | undefined
|
|
86255
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
86256
|
+
relative_humidity?: number | undefined
|
|
86257
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
86258
|
+
noise_level_decibels?: number | undefined
|
|
86259
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
86260
|
+
noise_level_nrs?: number | undefined
|
|
86261
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
86262
|
+
co2_ppm?: number | undefined
|
|
86263
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
86264
|
+
co_ppm?: number | undefined
|
|
86265
|
+
/** Air quality index, if the device measures it. */
|
|
86266
|
+
air_quality_index?: number | undefined
|
|
86267
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
86268
|
+
mold_risk_level?: string | undefined
|
|
86269
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
86270
|
+
is_occupied?: boolean | undefined
|
|
86271
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
86272
|
+
occupant_count?: number | undefined
|
|
86273
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
86274
|
+
is_smoking_detected?: boolean | undefined
|
|
86275
|
+
}[]
|
|
86276
|
+
| undefined
|
|
86049
86277
|
/** Indicates whether the device supports remote unlocking. */
|
|
86050
86278
|
can_remotely_unlock?: boolean | undefined
|
|
86051
86279
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -96355,7 +96583,7 @@ export type Routes = {
|
|
|
96355
96583
|
/** Device types of the noise sensors that you want to list. */
|
|
96356
96584
|
device_types?: ('noiseaware_activity_zone' | 'minut_sensor')[] | undefined
|
|
96357
96585
|
/** Manufacturers of the noise sensors that you want to list. */
|
|
96358
|
-
manufacturer?: ('minut' | 'noiseaware') | undefined
|
|
96586
|
+
manufacturer?: ('minut' | 'noiseaware' | 'alertify') | undefined
|
|
96359
96587
|
}
|
|
96360
96588
|
formData: {}
|
|
96361
96589
|
jsonResponse: {
|
|
@@ -96420,6 +96648,7 @@ export type Routes = {
|
|
|
96420
96648
|
| 'unifi_protect_camera'
|
|
96421
96649
|
)
|
|
96422
96650
|
| 'sonos_speaker'
|
|
96651
|
+
| 'alertify_sensor'
|
|
96423
96652
|
/** IDs of the spaces the device is in. */
|
|
96424
96653
|
space_ids: string[]
|
|
96425
96654
|
/** Optional nickname to describe the device, settable through Seam. */
|
|
@@ -96528,58 +96757,9 @@ export type Routes = {
|
|
|
96528
96757
|
* @deprecated use offline_access_codes_enabled*/
|
|
96529
96758
|
supports_offline_access_codes?: boolean | undefined
|
|
96530
96759
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
96531
|
-
noise_level_decibels?:
|
|
96760
|
+
noise_level_decibels?: number | undefined
|
|
96532
96761
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
96533
96762
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
96534
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
96535
|
-
noise_level_nrs?: (number | null) | undefined
|
|
96536
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
96537
|
-
co2_ppm?: (number | null) | undefined
|
|
96538
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
96539
|
-
co_ppm?: (number | null) | undefined
|
|
96540
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
96541
|
-
air_quality_index?: (number | null) | undefined
|
|
96542
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
96543
|
-
mold_risk_level?: (string | null) | undefined
|
|
96544
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
96545
|
-
is_occupied?: (boolean | null) | undefined
|
|
96546
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
96547
|
-
occupant_count?: (number | null) | undefined
|
|
96548
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
96549
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
96550
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
96551
|
-
named_sensors?:
|
|
96552
|
-
| {
|
|
96553
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
96554
|
-
sensor_name: string
|
|
96555
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
96556
|
-
display_name: string
|
|
96557
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
96558
|
-
temperature_celsius?: (number | null) | undefined
|
|
96559
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
96560
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
96561
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
96562
|
-
relative_humidity?: (number | null) | undefined
|
|
96563
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
96564
|
-
noise_level_decibels?: (number | null) | undefined
|
|
96565
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
96566
|
-
noise_level_nrs?: (number | null) | undefined
|
|
96567
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
96568
|
-
co2_ppm?: (number | null) | undefined
|
|
96569
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
96570
|
-
co_ppm?: (number | null) | undefined
|
|
96571
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
96572
|
-
air_quality_index?: (number | null) | undefined
|
|
96573
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
96574
|
-
mold_risk_level?: (string | null) | undefined
|
|
96575
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
96576
|
-
is_occupied?: (boolean | null) | undefined
|
|
96577
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
96578
|
-
occupant_count?: (number | null) | undefined
|
|
96579
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
96580
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
96581
|
-
}[]
|
|
96582
|
-
| undefined
|
|
96583
96763
|
} & {
|
|
96584
96764
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
96585
96765
|
assa_abloy_credential_service_metadata?:
|
|
@@ -97321,6 +97501,24 @@ export type Routes = {
|
|
|
97321
97501
|
| undefined
|
|
97322
97502
|
)
|
|
97323
97503
|
| undefined
|
|
97504
|
+
/** Metadata for an Alertify sensor. */
|
|
97505
|
+
alertify_metadata?:
|
|
97506
|
+
| (
|
|
97507
|
+
| {
|
|
97508
|
+
/** Device ID reported by Alertify. */
|
|
97509
|
+
device_id?: (string | undefined) | undefined
|
|
97510
|
+
/** Device name, as set in the Alertify dashboard. */
|
|
97511
|
+
device_name?: (string | undefined) | undefined
|
|
97512
|
+
/** ID of the Alertify unit where the device is installed. */
|
|
97513
|
+
unit_id?: (string | undefined) | undefined
|
|
97514
|
+
/** Name of the Alertify unit where the device is installed. */
|
|
97515
|
+
unit_name?: (string | undefined) | undefined
|
|
97516
|
+
/** ID of the Alertify building that contains the unit. */
|
|
97517
|
+
building_id?: ((string | null) | undefined) | undefined
|
|
97518
|
+
}
|
|
97519
|
+
| undefined
|
|
97520
|
+
)
|
|
97521
|
+
| undefined
|
|
97324
97522
|
/** Metadata for a UniFi Protect camera. */
|
|
97325
97523
|
unifi_protect_metadata?:
|
|
97326
97524
|
| (
|
|
@@ -97619,11 +97817,11 @@ export type Routes = {
|
|
|
97619
97817
|
| undefined
|
|
97620
97818
|
} & {
|
|
97621
97819
|
/** Reported temperature in °F. */
|
|
97622
|
-
temperature_fahrenheit?:
|
|
97820
|
+
temperature_fahrenheit?: number | undefined
|
|
97623
97821
|
/** Reported temperature in °C. */
|
|
97624
|
-
temperature_celsius?:
|
|
97822
|
+
temperature_celsius?: number | undefined
|
|
97625
97823
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
97626
|
-
relative_humidity?:
|
|
97824
|
+
relative_humidity?: number | undefined
|
|
97627
97825
|
/** HVAC mode settings that the thermostat supports. */
|
|
97628
97826
|
available_hvac_mode_settings?:
|
|
97629
97827
|
('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined
|
|
@@ -98436,6 +98634,63 @@ export type Routes = {
|
|
|
98436
98634
|
image_url?: string | undefined
|
|
98437
98635
|
}
|
|
98438
98636
|
| undefined
|
|
98637
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
98638
|
+
temperature_celsius?: number | undefined
|
|
98639
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
98640
|
+
temperature_fahrenheit?: number | undefined
|
|
98641
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
98642
|
+
relative_humidity?: number | undefined
|
|
98643
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
98644
|
+
noise_level_decibels?: number | undefined
|
|
98645
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
98646
|
+
noise_level_nrs?: number | undefined
|
|
98647
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
98648
|
+
co2_ppm?: number | undefined
|
|
98649
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
98650
|
+
co_ppm?: number | undefined
|
|
98651
|
+
/** Air quality index, if the device measures it. */
|
|
98652
|
+
air_quality_index?: number | undefined
|
|
98653
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
98654
|
+
mold_risk_level?: string | undefined
|
|
98655
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
98656
|
+
is_occupied?: boolean | undefined
|
|
98657
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
98658
|
+
occupant_count?: number | undefined
|
|
98659
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
98660
|
+
is_smoking_detected?: boolean | undefined
|
|
98661
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
98662
|
+
named_sensors?:
|
|
98663
|
+
| {
|
|
98664
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
98665
|
+
sensor_name: string
|
|
98666
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
98667
|
+
display_name: string
|
|
98668
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
98669
|
+
temperature_celsius?: number | undefined
|
|
98670
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
98671
|
+
temperature_fahrenheit?: number | undefined
|
|
98672
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
98673
|
+
relative_humidity?: number | undefined
|
|
98674
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
98675
|
+
noise_level_decibels?: number | undefined
|
|
98676
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
98677
|
+
noise_level_nrs?: number | undefined
|
|
98678
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
98679
|
+
co2_ppm?: number | undefined
|
|
98680
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
98681
|
+
co_ppm?: number | undefined
|
|
98682
|
+
/** Air quality index, if the device measures it. */
|
|
98683
|
+
air_quality_index?: number | undefined
|
|
98684
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
98685
|
+
mold_risk_level?: string | undefined
|
|
98686
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
98687
|
+
is_occupied?: boolean | undefined
|
|
98688
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
98689
|
+
occupant_count?: number | undefined
|
|
98690
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
98691
|
+
is_smoking_detected?: boolean | undefined
|
|
98692
|
+
}[]
|
|
98693
|
+
| undefined
|
|
98439
98694
|
/** Indicates whether the device supports remote unlocking. */
|
|
98440
98695
|
can_remotely_unlock?: boolean | undefined
|
|
98441
98696
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -98559,6 +98814,7 @@ export type Routes = {
|
|
|
98559
98814
|
| 'unifi_protect_camera'
|
|
98560
98815
|
)
|
|
98561
98816
|
| 'sonos_speaker'
|
|
98817
|
+
| 'alertify_sensor'
|
|
98562
98818
|
/** IDs of the spaces the device is in. */
|
|
98563
98819
|
space_ids: string[]
|
|
98564
98820
|
/** Optional nickname to describe the device, settable through Seam. */
|
|
@@ -98667,58 +98923,9 @@ export type Routes = {
|
|
|
98667
98923
|
* @deprecated use offline_access_codes_enabled*/
|
|
98668
98924
|
supports_offline_access_codes?: boolean | undefined
|
|
98669
98925
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
98670
|
-
noise_level_decibels?:
|
|
98926
|
+
noise_level_decibels?: number | undefined
|
|
98671
98927
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
98672
98928
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
98673
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
98674
|
-
noise_level_nrs?: (number | null) | undefined
|
|
98675
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
98676
|
-
co2_ppm?: (number | null) | undefined
|
|
98677
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
98678
|
-
co_ppm?: (number | null) | undefined
|
|
98679
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
98680
|
-
air_quality_index?: (number | null) | undefined
|
|
98681
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
98682
|
-
mold_risk_level?: (string | null) | undefined
|
|
98683
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
98684
|
-
is_occupied?: (boolean | null) | undefined
|
|
98685
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
98686
|
-
occupant_count?: (number | null) | undefined
|
|
98687
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
98688
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
98689
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
98690
|
-
named_sensors?:
|
|
98691
|
-
| {
|
|
98692
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
98693
|
-
sensor_name: string
|
|
98694
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
98695
|
-
display_name: string
|
|
98696
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
98697
|
-
temperature_celsius?: (number | null) | undefined
|
|
98698
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
98699
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
98700
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
98701
|
-
relative_humidity?: (number | null) | undefined
|
|
98702
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
98703
|
-
noise_level_decibels?: (number | null) | undefined
|
|
98704
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
98705
|
-
noise_level_nrs?: (number | null) | undefined
|
|
98706
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
98707
|
-
co2_ppm?: (number | null) | undefined
|
|
98708
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
98709
|
-
co_ppm?: (number | null) | undefined
|
|
98710
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
98711
|
-
air_quality_index?: (number | null) | undefined
|
|
98712
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
98713
|
-
mold_risk_level?: (string | null) | undefined
|
|
98714
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
98715
|
-
is_occupied?: (boolean | null) | undefined
|
|
98716
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
98717
|
-
occupant_count?: (number | null) | undefined
|
|
98718
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
98719
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
98720
|
-
}[]
|
|
98721
|
-
| undefined
|
|
98722
98929
|
} & {
|
|
98723
98930
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
98724
98931
|
assa_abloy_credential_service_metadata?:
|
|
@@ -99460,6 +99667,24 @@ export type Routes = {
|
|
|
99460
99667
|
| undefined
|
|
99461
99668
|
)
|
|
99462
99669
|
| undefined
|
|
99670
|
+
/** Metadata for an Alertify sensor. */
|
|
99671
|
+
alertify_metadata?:
|
|
99672
|
+
| (
|
|
99673
|
+
| {
|
|
99674
|
+
/** Device ID reported by Alertify. */
|
|
99675
|
+
device_id?: (string | undefined) | undefined
|
|
99676
|
+
/** Device name, as set in the Alertify dashboard. */
|
|
99677
|
+
device_name?: (string | undefined) | undefined
|
|
99678
|
+
/** ID of the Alertify unit where the device is installed. */
|
|
99679
|
+
unit_id?: (string | undefined) | undefined
|
|
99680
|
+
/** Name of the Alertify unit where the device is installed. */
|
|
99681
|
+
unit_name?: (string | undefined) | undefined
|
|
99682
|
+
/** ID of the Alertify building that contains the unit. */
|
|
99683
|
+
building_id?: ((string | null) | undefined) | undefined
|
|
99684
|
+
}
|
|
99685
|
+
| undefined
|
|
99686
|
+
)
|
|
99687
|
+
| undefined
|
|
99463
99688
|
/** Metadata for a UniFi Protect camera. */
|
|
99464
99689
|
unifi_protect_metadata?:
|
|
99465
99690
|
| (
|
|
@@ -99758,11 +99983,11 @@ export type Routes = {
|
|
|
99758
99983
|
| undefined
|
|
99759
99984
|
} & {
|
|
99760
99985
|
/** Reported temperature in °F. */
|
|
99761
|
-
temperature_fahrenheit?:
|
|
99986
|
+
temperature_fahrenheit?: number | undefined
|
|
99762
99987
|
/** Reported temperature in °C. */
|
|
99763
|
-
temperature_celsius?:
|
|
99988
|
+
temperature_celsius?: number | undefined
|
|
99764
99989
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
99765
|
-
relative_humidity?:
|
|
99990
|
+
relative_humidity?: number | undefined
|
|
99766
99991
|
/** HVAC mode settings that the thermostat supports. */
|
|
99767
99992
|
available_hvac_mode_settings?:
|
|
99768
99993
|
('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined
|
|
@@ -100575,6 +100800,63 @@ export type Routes = {
|
|
|
100575
100800
|
image_url?: string | undefined
|
|
100576
100801
|
}
|
|
100577
100802
|
| undefined
|
|
100803
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
100804
|
+
temperature_celsius?: number | undefined
|
|
100805
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
100806
|
+
temperature_fahrenheit?: number | undefined
|
|
100807
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
100808
|
+
relative_humidity?: number | undefined
|
|
100809
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
100810
|
+
noise_level_decibels?: number | undefined
|
|
100811
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
100812
|
+
noise_level_nrs?: number | undefined
|
|
100813
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
100814
|
+
co2_ppm?: number | undefined
|
|
100815
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
100816
|
+
co_ppm?: number | undefined
|
|
100817
|
+
/** Air quality index, if the device measures it. */
|
|
100818
|
+
air_quality_index?: number | undefined
|
|
100819
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
100820
|
+
mold_risk_level?: string | undefined
|
|
100821
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
100822
|
+
is_occupied?: boolean | undefined
|
|
100823
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
100824
|
+
occupant_count?: number | undefined
|
|
100825
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
100826
|
+
is_smoking_detected?: boolean | undefined
|
|
100827
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
100828
|
+
named_sensors?:
|
|
100829
|
+
| {
|
|
100830
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
100831
|
+
sensor_name: string
|
|
100832
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
100833
|
+
display_name: string
|
|
100834
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
100835
|
+
temperature_celsius?: number | undefined
|
|
100836
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
100837
|
+
temperature_fahrenheit?: number | undefined
|
|
100838
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
100839
|
+
relative_humidity?: number | undefined
|
|
100840
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
100841
|
+
noise_level_decibels?: number | undefined
|
|
100842
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
100843
|
+
noise_level_nrs?: number | undefined
|
|
100844
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
100845
|
+
co2_ppm?: number | undefined
|
|
100846
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
100847
|
+
co_ppm?: number | undefined
|
|
100848
|
+
/** Air quality index, if the device measures it. */
|
|
100849
|
+
air_quality_index?: number | undefined
|
|
100850
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
100851
|
+
mold_risk_level?: string | undefined
|
|
100852
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
100853
|
+
is_occupied?: boolean | undefined
|
|
100854
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
100855
|
+
occupant_count?: number | undefined
|
|
100856
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
100857
|
+
is_smoking_detected?: boolean | undefined
|
|
100858
|
+
}[]
|
|
100859
|
+
| undefined
|
|
100578
100860
|
/** Indicates whether the device supports remote unlocking. */
|
|
100579
100861
|
can_remotely_unlock?: boolean | undefined
|
|
100580
100862
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -128303,6 +128585,7 @@ export type Routes = {
|
|
|
128303
128585
|
| 'unifi_protect_camera'
|
|
128304
128586
|
)
|
|
128305
128587
|
| 'sonos_speaker'
|
|
128588
|
+
| 'alertify_sensor'
|
|
128306
128589
|
/** IDs of the spaces the device is in. */
|
|
128307
128590
|
space_ids: string[]
|
|
128308
128591
|
/** Optional nickname to describe the device, settable through Seam. */
|
|
@@ -128411,58 +128694,9 @@ export type Routes = {
|
|
|
128411
128694
|
* @deprecated use offline_access_codes_enabled*/
|
|
128412
128695
|
supports_offline_access_codes?: boolean | undefined
|
|
128413
128696
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
128414
|
-
noise_level_decibels?:
|
|
128697
|
+
noise_level_decibels?: number | undefined
|
|
128415
128698
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
128416
128699
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
128417
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
128418
|
-
noise_level_nrs?: (number | null) | undefined
|
|
128419
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
128420
|
-
co2_ppm?: (number | null) | undefined
|
|
128421
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
128422
|
-
co_ppm?: (number | null) | undefined
|
|
128423
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
128424
|
-
air_quality_index?: (number | null) | undefined
|
|
128425
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
128426
|
-
mold_risk_level?: (string | null) | undefined
|
|
128427
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
128428
|
-
is_occupied?: (boolean | null) | undefined
|
|
128429
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
128430
|
-
occupant_count?: (number | null) | undefined
|
|
128431
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
128432
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
128433
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
128434
|
-
named_sensors?:
|
|
128435
|
-
| {
|
|
128436
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
128437
|
-
sensor_name: string
|
|
128438
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
128439
|
-
display_name: string
|
|
128440
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
128441
|
-
temperature_celsius?: (number | null) | undefined
|
|
128442
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
128443
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
128444
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
128445
|
-
relative_humidity?: (number | null) | undefined
|
|
128446
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
128447
|
-
noise_level_decibels?: (number | null) | undefined
|
|
128448
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
128449
|
-
noise_level_nrs?: (number | null) | undefined
|
|
128450
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
128451
|
-
co2_ppm?: (number | null) | undefined
|
|
128452
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
128453
|
-
co_ppm?: (number | null) | undefined
|
|
128454
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
128455
|
-
air_quality_index?: (number | null) | undefined
|
|
128456
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
128457
|
-
mold_risk_level?: (string | null) | undefined
|
|
128458
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
128459
|
-
is_occupied?: (boolean | null) | undefined
|
|
128460
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
128461
|
-
occupant_count?: (number | null) | undefined
|
|
128462
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
128463
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
128464
|
-
}[]
|
|
128465
|
-
| undefined
|
|
128466
128700
|
} & {
|
|
128467
128701
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
128468
128702
|
assa_abloy_credential_service_metadata?:
|
|
@@ -129229,6 +129463,25 @@ export type Routes = {
|
|
|
129229
129463
|
| undefined
|
|
129230
129464
|
)
|
|
129231
129465
|
| undefined
|
|
129466
|
+
/** Metadata for an Alertify sensor. */
|
|
129467
|
+
alertify_metadata?:
|
|
129468
|
+
| (
|
|
129469
|
+
| {
|
|
129470
|
+
/** Device ID reported by Alertify. */
|
|
129471
|
+
device_id?: (string | undefined) | undefined
|
|
129472
|
+
/** Device name, as set in the Alertify dashboard. */
|
|
129473
|
+
device_name?: (string | undefined) | undefined
|
|
129474
|
+
/** ID of the Alertify unit where the device is installed. */
|
|
129475
|
+
unit_id?: (string | undefined) | undefined
|
|
129476
|
+
/** Name of the Alertify unit where the device is installed. */
|
|
129477
|
+
unit_name?: (string | undefined) | undefined
|
|
129478
|
+
/** ID of the Alertify building that contains the unit. */
|
|
129479
|
+
building_id?:
|
|
129480
|
+
((string | null) | undefined) | undefined
|
|
129481
|
+
}
|
|
129482
|
+
| undefined
|
|
129483
|
+
)
|
|
129484
|
+
| undefined
|
|
129232
129485
|
/** Metadata for a UniFi Protect camera. */
|
|
129233
129486
|
unifi_protect_metadata?:
|
|
129234
129487
|
| (
|
|
@@ -129536,11 +129789,11 @@ export type Routes = {
|
|
|
129536
129789
|
| undefined
|
|
129537
129790
|
} & {
|
|
129538
129791
|
/** Reported temperature in °F. */
|
|
129539
|
-
temperature_fahrenheit?:
|
|
129792
|
+
temperature_fahrenheit?: number | undefined
|
|
129540
129793
|
/** Reported temperature in °C. */
|
|
129541
|
-
temperature_celsius?:
|
|
129794
|
+
temperature_celsius?: number | undefined
|
|
129542
129795
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
129543
|
-
relative_humidity?:
|
|
129796
|
+
relative_humidity?: number | undefined
|
|
129544
129797
|
/** HVAC mode settings that the thermostat supports. */
|
|
129545
129798
|
available_hvac_mode_settings?:
|
|
129546
129799
|
| ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[]
|
|
@@ -130375,6 +130628,63 @@ export type Routes = {
|
|
|
130375
130628
|
image_url?: string | undefined
|
|
130376
130629
|
}
|
|
130377
130630
|
| undefined
|
|
130631
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
130632
|
+
temperature_celsius?: number | undefined
|
|
130633
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
130634
|
+
temperature_fahrenheit?: number | undefined
|
|
130635
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
130636
|
+
relative_humidity?: number | undefined
|
|
130637
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
130638
|
+
noise_level_decibels?: number | undefined
|
|
130639
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
130640
|
+
noise_level_nrs?: number | undefined
|
|
130641
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
130642
|
+
co2_ppm?: number | undefined
|
|
130643
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
130644
|
+
co_ppm?: number | undefined
|
|
130645
|
+
/** Air quality index, if the device measures it. */
|
|
130646
|
+
air_quality_index?: number | undefined
|
|
130647
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
130648
|
+
mold_risk_level?: string | undefined
|
|
130649
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
130650
|
+
is_occupied?: boolean | undefined
|
|
130651
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
130652
|
+
occupant_count?: number | undefined
|
|
130653
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
130654
|
+
is_smoking_detected?: boolean | undefined
|
|
130655
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
130656
|
+
named_sensors?:
|
|
130657
|
+
| {
|
|
130658
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
130659
|
+
sensor_name: string
|
|
130660
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
130661
|
+
display_name: string
|
|
130662
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
130663
|
+
temperature_celsius?: number | undefined
|
|
130664
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
130665
|
+
temperature_fahrenheit?: number | undefined
|
|
130666
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
130667
|
+
relative_humidity?: number | undefined
|
|
130668
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
130669
|
+
noise_level_decibels?: number | undefined
|
|
130670
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
130671
|
+
noise_level_nrs?: number | undefined
|
|
130672
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
130673
|
+
co2_ppm?: number | undefined
|
|
130674
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
130675
|
+
co_ppm?: number | undefined
|
|
130676
|
+
/** Air quality index, if the device measures it. */
|
|
130677
|
+
air_quality_index?: number | undefined
|
|
130678
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
130679
|
+
mold_risk_level?: string | undefined
|
|
130680
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
130681
|
+
is_occupied?: boolean | undefined
|
|
130682
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
130683
|
+
occupant_count?: number | undefined
|
|
130684
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
130685
|
+
is_smoking_detected?: boolean | undefined
|
|
130686
|
+
}[]
|
|
130687
|
+
| undefined
|
|
130378
130688
|
/** Indicates whether the device supports remote unlocking. */
|
|
130379
130689
|
can_remotely_unlock?: boolean | undefined
|
|
130380
130690
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -162399,6 +162709,7 @@ export type Routes = {
|
|
|
162399
162709
|
| 'unifi_protect_camera'
|
|
162400
162710
|
)
|
|
162401
162711
|
| 'sonos_speaker'
|
|
162712
|
+
| 'alertify_sensor'
|
|
162402
162713
|
/** IDs of the spaces the device is in. */
|
|
162403
162714
|
space_ids: string[]
|
|
162404
162715
|
/** Optional nickname to describe the device, settable through Seam. */
|
|
@@ -162507,58 +162818,9 @@ export type Routes = {
|
|
|
162507
162818
|
* @deprecated use offline_access_codes_enabled*/
|
|
162508
162819
|
supports_offline_access_codes?: boolean | undefined
|
|
162509
162820
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
162510
|
-
noise_level_decibels?:
|
|
162821
|
+
noise_level_decibels?: number | undefined
|
|
162511
162822
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
162512
162823
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
162513
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
162514
|
-
noise_level_nrs?: (number | null) | undefined
|
|
162515
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
162516
|
-
co2_ppm?: (number | null) | undefined
|
|
162517
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
162518
|
-
co_ppm?: (number | null) | undefined
|
|
162519
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
162520
|
-
air_quality_index?: (number | null) | undefined
|
|
162521
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
162522
|
-
mold_risk_level?: (string | null) | undefined
|
|
162523
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
162524
|
-
is_occupied?: (boolean | null) | undefined
|
|
162525
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
162526
|
-
occupant_count?: (number | null) | undefined
|
|
162527
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
162528
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
162529
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
162530
|
-
named_sensors?:
|
|
162531
|
-
| {
|
|
162532
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
162533
|
-
sensor_name: string
|
|
162534
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
162535
|
-
display_name: string
|
|
162536
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
162537
|
-
temperature_celsius?: (number | null) | undefined
|
|
162538
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
162539
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
162540
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
162541
|
-
relative_humidity?: (number | null) | undefined
|
|
162542
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
162543
|
-
noise_level_decibels?: (number | null) | undefined
|
|
162544
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
162545
|
-
noise_level_nrs?: (number | null) | undefined
|
|
162546
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
162547
|
-
co2_ppm?: (number | null) | undefined
|
|
162548
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
162549
|
-
co_ppm?: (number | null) | undefined
|
|
162550
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
162551
|
-
air_quality_index?: (number | null) | undefined
|
|
162552
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
162553
|
-
mold_risk_level?: (string | null) | undefined
|
|
162554
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
162555
|
-
is_occupied?: (boolean | null) | undefined
|
|
162556
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
162557
|
-
occupant_count?: (number | null) | undefined
|
|
162558
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
162559
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
162560
|
-
}[]
|
|
162561
|
-
| undefined
|
|
162562
162824
|
} & {
|
|
162563
162825
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
162564
162826
|
assa_abloy_credential_service_metadata?:
|
|
@@ -163300,6 +163562,24 @@ export type Routes = {
|
|
|
163300
163562
|
| undefined
|
|
163301
163563
|
)
|
|
163302
163564
|
| undefined
|
|
163565
|
+
/** Metadata for an Alertify sensor. */
|
|
163566
|
+
alertify_metadata?:
|
|
163567
|
+
| (
|
|
163568
|
+
| {
|
|
163569
|
+
/** Device ID reported by Alertify. */
|
|
163570
|
+
device_id?: (string | undefined) | undefined
|
|
163571
|
+
/** Device name, as set in the Alertify dashboard. */
|
|
163572
|
+
device_name?: (string | undefined) | undefined
|
|
163573
|
+
/** ID of the Alertify unit where the device is installed. */
|
|
163574
|
+
unit_id?: (string | undefined) | undefined
|
|
163575
|
+
/** Name of the Alertify unit where the device is installed. */
|
|
163576
|
+
unit_name?: (string | undefined) | undefined
|
|
163577
|
+
/** ID of the Alertify building that contains the unit. */
|
|
163578
|
+
building_id?: ((string | null) | undefined) | undefined
|
|
163579
|
+
}
|
|
163580
|
+
| undefined
|
|
163581
|
+
)
|
|
163582
|
+
| undefined
|
|
163303
163583
|
/** Metadata for a UniFi Protect camera. */
|
|
163304
163584
|
unifi_protect_metadata?:
|
|
163305
163585
|
| (
|
|
@@ -163598,11 +163878,11 @@ export type Routes = {
|
|
|
163598
163878
|
| undefined
|
|
163599
163879
|
} & {
|
|
163600
163880
|
/** Reported temperature in °F. */
|
|
163601
|
-
temperature_fahrenheit?:
|
|
163881
|
+
temperature_fahrenheit?: number | undefined
|
|
163602
163882
|
/** Reported temperature in °C. */
|
|
163603
|
-
temperature_celsius?:
|
|
163883
|
+
temperature_celsius?: number | undefined
|
|
163604
163884
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
163605
|
-
relative_humidity?:
|
|
163885
|
+
relative_humidity?: number | undefined
|
|
163606
163886
|
/** HVAC mode settings that the thermostat supports. */
|
|
163607
163887
|
available_hvac_mode_settings?:
|
|
163608
163888
|
('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined
|
|
@@ -164415,6 +164695,63 @@ export type Routes = {
|
|
|
164415
164695
|
image_url?: string | undefined
|
|
164416
164696
|
}
|
|
164417
164697
|
| undefined
|
|
164698
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
164699
|
+
temperature_celsius?: number | undefined
|
|
164700
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
164701
|
+
temperature_fahrenheit?: number | undefined
|
|
164702
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
164703
|
+
relative_humidity?: number | undefined
|
|
164704
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
164705
|
+
noise_level_decibels?: number | undefined
|
|
164706
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
164707
|
+
noise_level_nrs?: number | undefined
|
|
164708
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
164709
|
+
co2_ppm?: number | undefined
|
|
164710
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
164711
|
+
co_ppm?: number | undefined
|
|
164712
|
+
/** Air quality index, if the device measures it. */
|
|
164713
|
+
air_quality_index?: number | undefined
|
|
164714
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
164715
|
+
mold_risk_level?: string | undefined
|
|
164716
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
164717
|
+
is_occupied?: boolean | undefined
|
|
164718
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
164719
|
+
occupant_count?: number | undefined
|
|
164720
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
164721
|
+
is_smoking_detected?: boolean | undefined
|
|
164722
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
164723
|
+
named_sensors?:
|
|
164724
|
+
| {
|
|
164725
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
164726
|
+
sensor_name: string
|
|
164727
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
164728
|
+
display_name: string
|
|
164729
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
164730
|
+
temperature_celsius?: number | undefined
|
|
164731
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
164732
|
+
temperature_fahrenheit?: number | undefined
|
|
164733
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
164734
|
+
relative_humidity?: number | undefined
|
|
164735
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
164736
|
+
noise_level_decibels?: number | undefined
|
|
164737
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
164738
|
+
noise_level_nrs?: number | undefined
|
|
164739
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
164740
|
+
co2_ppm?: number | undefined
|
|
164741
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
164742
|
+
co_ppm?: number | undefined
|
|
164743
|
+
/** Air quality index, if the device measures it. */
|
|
164744
|
+
air_quality_index?: number | undefined
|
|
164745
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
164746
|
+
mold_risk_level?: string | undefined
|
|
164747
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
164748
|
+
is_occupied?: boolean | undefined
|
|
164749
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
164750
|
+
occupant_count?: number | undefined
|
|
164751
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
164752
|
+
is_smoking_detected?: boolean | undefined
|
|
164753
|
+
}[]
|
|
164754
|
+
| undefined
|
|
164418
164755
|
/** Indicates whether the device supports remote unlocking. */
|
|
164419
164756
|
can_remotely_unlock?: boolean | undefined
|
|
164420
164757
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -169695,6 +170032,7 @@ export type Routes = {
|
|
|
169695
170032
|
| 'unifi_protect_camera'
|
|
169696
170033
|
)
|
|
169697
170034
|
| 'sonos_speaker'
|
|
170035
|
+
| 'alertify_sensor'
|
|
169698
170036
|
/** IDs of the spaces the device is in. */
|
|
169699
170037
|
space_ids: string[]
|
|
169700
170038
|
/** Optional nickname to describe the device, settable through Seam. */
|
|
@@ -169803,58 +170141,9 @@ export type Routes = {
|
|
|
169803
170141
|
* @deprecated use offline_access_codes_enabled*/
|
|
169804
170142
|
supports_offline_access_codes?: boolean | undefined
|
|
169805
170143
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
169806
|
-
noise_level_decibels?:
|
|
170144
|
+
noise_level_decibels?: number | undefined
|
|
169807
170145
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
169808
170146
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
169809
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
169810
|
-
noise_level_nrs?: (number | null) | undefined
|
|
169811
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
169812
|
-
co2_ppm?: (number | null) | undefined
|
|
169813
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
169814
|
-
co_ppm?: (number | null) | undefined
|
|
169815
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
169816
|
-
air_quality_index?: (number | null) | undefined
|
|
169817
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
169818
|
-
mold_risk_level?: (string | null) | undefined
|
|
169819
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
169820
|
-
is_occupied?: (boolean | null) | undefined
|
|
169821
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
169822
|
-
occupant_count?: (number | null) | undefined
|
|
169823
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
169824
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
169825
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
169826
|
-
named_sensors?:
|
|
169827
|
-
| {
|
|
169828
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
169829
|
-
sensor_name: string
|
|
169830
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
169831
|
-
display_name: string
|
|
169832
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
169833
|
-
temperature_celsius?: (number | null) | undefined
|
|
169834
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
169835
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
169836
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
169837
|
-
relative_humidity?: (number | null) | undefined
|
|
169838
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
169839
|
-
noise_level_decibels?: (number | null) | undefined
|
|
169840
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
169841
|
-
noise_level_nrs?: (number | null) | undefined
|
|
169842
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
169843
|
-
co2_ppm?: (number | null) | undefined
|
|
169844
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
169845
|
-
co_ppm?: (number | null) | undefined
|
|
169846
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
169847
|
-
air_quality_index?: (number | null) | undefined
|
|
169848
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
169849
|
-
mold_risk_level?: (string | null) | undefined
|
|
169850
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
169851
|
-
is_occupied?: (boolean | null) | undefined
|
|
169852
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
169853
|
-
occupant_count?: (number | null) | undefined
|
|
169854
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
169855
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
169856
|
-
}[]
|
|
169857
|
-
| undefined
|
|
169858
170147
|
} & {
|
|
169859
170148
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
169860
170149
|
assa_abloy_credential_service_metadata?:
|
|
@@ -170596,6 +170885,24 @@ export type Routes = {
|
|
|
170596
170885
|
| undefined
|
|
170597
170886
|
)
|
|
170598
170887
|
| undefined
|
|
170888
|
+
/** Metadata for an Alertify sensor. */
|
|
170889
|
+
alertify_metadata?:
|
|
170890
|
+
| (
|
|
170891
|
+
| {
|
|
170892
|
+
/** Device ID reported by Alertify. */
|
|
170893
|
+
device_id?: (string | undefined) | undefined
|
|
170894
|
+
/** Device name, as set in the Alertify dashboard. */
|
|
170895
|
+
device_name?: (string | undefined) | undefined
|
|
170896
|
+
/** ID of the Alertify unit where the device is installed. */
|
|
170897
|
+
unit_id?: (string | undefined) | undefined
|
|
170898
|
+
/** Name of the Alertify unit where the device is installed. */
|
|
170899
|
+
unit_name?: (string | undefined) | undefined
|
|
170900
|
+
/** ID of the Alertify building that contains the unit. */
|
|
170901
|
+
building_id?: ((string | null) | undefined) | undefined
|
|
170902
|
+
}
|
|
170903
|
+
| undefined
|
|
170904
|
+
)
|
|
170905
|
+
| undefined
|
|
170599
170906
|
/** Metadata for a UniFi Protect camera. */
|
|
170600
170907
|
unifi_protect_metadata?:
|
|
170601
170908
|
| (
|
|
@@ -170894,11 +171201,11 @@ export type Routes = {
|
|
|
170894
171201
|
| undefined
|
|
170895
171202
|
} & {
|
|
170896
171203
|
/** Reported temperature in °F. */
|
|
170897
|
-
temperature_fahrenheit?:
|
|
171204
|
+
temperature_fahrenheit?: number | undefined
|
|
170898
171205
|
/** Reported temperature in °C. */
|
|
170899
|
-
temperature_celsius?:
|
|
171206
|
+
temperature_celsius?: number | undefined
|
|
170900
171207
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
170901
|
-
relative_humidity?:
|
|
171208
|
+
relative_humidity?: number | undefined
|
|
170902
171209
|
/** HVAC mode settings that the thermostat supports. */
|
|
170903
171210
|
available_hvac_mode_settings?:
|
|
170904
171211
|
('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined
|
|
@@ -171711,6 +172018,63 @@ export type Routes = {
|
|
|
171711
172018
|
image_url?: string | undefined
|
|
171712
172019
|
}
|
|
171713
172020
|
| undefined
|
|
172021
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
172022
|
+
temperature_celsius?: number | undefined
|
|
172023
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
172024
|
+
temperature_fahrenheit?: number | undefined
|
|
172025
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
172026
|
+
relative_humidity?: number | undefined
|
|
172027
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
172028
|
+
noise_level_decibels?: number | undefined
|
|
172029
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
172030
|
+
noise_level_nrs?: number | undefined
|
|
172031
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
172032
|
+
co2_ppm?: number | undefined
|
|
172033
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
172034
|
+
co_ppm?: number | undefined
|
|
172035
|
+
/** Air quality index, if the device measures it. */
|
|
172036
|
+
air_quality_index?: number | undefined
|
|
172037
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
172038
|
+
mold_risk_level?: string | undefined
|
|
172039
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
172040
|
+
is_occupied?: boolean | undefined
|
|
172041
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
172042
|
+
occupant_count?: number | undefined
|
|
172043
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
172044
|
+
is_smoking_detected?: boolean | undefined
|
|
172045
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
172046
|
+
named_sensors?:
|
|
172047
|
+
| {
|
|
172048
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
172049
|
+
sensor_name: string
|
|
172050
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
172051
|
+
display_name: string
|
|
172052
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
172053
|
+
temperature_celsius?: number | undefined
|
|
172054
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
172055
|
+
temperature_fahrenheit?: number | undefined
|
|
172056
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
172057
|
+
relative_humidity?: number | undefined
|
|
172058
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
172059
|
+
noise_level_decibels?: number | undefined
|
|
172060
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
172061
|
+
noise_level_nrs?: number | undefined
|
|
172062
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
172063
|
+
co2_ppm?: number | undefined
|
|
172064
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
172065
|
+
co_ppm?: number | undefined
|
|
172066
|
+
/** Air quality index, if the device measures it. */
|
|
172067
|
+
air_quality_index?: number | undefined
|
|
172068
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
172069
|
+
mold_risk_level?: string | undefined
|
|
172070
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
172071
|
+
is_occupied?: boolean | undefined
|
|
172072
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
172073
|
+
occupant_count?: number | undefined
|
|
172074
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
172075
|
+
is_smoking_detected?: boolean | undefined
|
|
172076
|
+
}[]
|
|
172077
|
+
| undefined
|
|
171714
172078
|
/** Indicates whether the device supports remote unlocking. */
|
|
171715
172079
|
can_remotely_unlock?: boolean | undefined
|
|
171716
172080
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -171834,6 +172198,7 @@ export type Routes = {
|
|
|
171834
172198
|
| 'unifi_protect_camera'
|
|
171835
172199
|
)
|
|
171836
172200
|
| 'sonos_speaker'
|
|
172201
|
+
| 'alertify_sensor'
|
|
171837
172202
|
/** IDs of the spaces the device is in. */
|
|
171838
172203
|
space_ids: string[]
|
|
171839
172204
|
/** Optional nickname to describe the device, settable through Seam. */
|
|
@@ -171942,58 +172307,9 @@ export type Routes = {
|
|
|
171942
172307
|
* @deprecated use offline_access_codes_enabled*/
|
|
171943
172308
|
supports_offline_access_codes?: boolean | undefined
|
|
171944
172309
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
171945
|
-
noise_level_decibels?:
|
|
172310
|
+
noise_level_decibels?: number | undefined
|
|
171946
172311
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
171947
172312
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
171948
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
171949
|
-
noise_level_nrs?: (number | null) | undefined
|
|
171950
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
171951
|
-
co2_ppm?: (number | null) | undefined
|
|
171952
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
171953
|
-
co_ppm?: (number | null) | undefined
|
|
171954
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
171955
|
-
air_quality_index?: (number | null) | undefined
|
|
171956
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
171957
|
-
mold_risk_level?: (string | null) | undefined
|
|
171958
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
171959
|
-
is_occupied?: (boolean | null) | undefined
|
|
171960
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
171961
|
-
occupant_count?: (number | null) | undefined
|
|
171962
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
171963
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
171964
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
171965
|
-
named_sensors?:
|
|
171966
|
-
| {
|
|
171967
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
171968
|
-
sensor_name: string
|
|
171969
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
171970
|
-
display_name: string
|
|
171971
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
171972
|
-
temperature_celsius?: (number | null) | undefined
|
|
171973
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
171974
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
171975
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
171976
|
-
relative_humidity?: (number | null) | undefined
|
|
171977
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
171978
|
-
noise_level_decibels?: (number | null) | undefined
|
|
171979
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
171980
|
-
noise_level_nrs?: (number | null) | undefined
|
|
171981
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
171982
|
-
co2_ppm?: (number | null) | undefined
|
|
171983
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
171984
|
-
co_ppm?: (number | null) | undefined
|
|
171985
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
171986
|
-
air_quality_index?: (number | null) | undefined
|
|
171987
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
171988
|
-
mold_risk_level?: (string | null) | undefined
|
|
171989
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
171990
|
-
is_occupied?: (boolean | null) | undefined
|
|
171991
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
171992
|
-
occupant_count?: (number | null) | undefined
|
|
171993
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
171994
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
171995
|
-
}[]
|
|
171996
|
-
| undefined
|
|
171997
172313
|
} & {
|
|
171998
172314
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
171999
172315
|
assa_abloy_credential_service_metadata?:
|
|
@@ -172735,6 +173051,24 @@ export type Routes = {
|
|
|
172735
173051
|
| undefined
|
|
172736
173052
|
)
|
|
172737
173053
|
| undefined
|
|
173054
|
+
/** Metadata for an Alertify sensor. */
|
|
173055
|
+
alertify_metadata?:
|
|
173056
|
+
| (
|
|
173057
|
+
| {
|
|
173058
|
+
/** Device ID reported by Alertify. */
|
|
173059
|
+
device_id?: (string | undefined) | undefined
|
|
173060
|
+
/** Device name, as set in the Alertify dashboard. */
|
|
173061
|
+
device_name?: (string | undefined) | undefined
|
|
173062
|
+
/** ID of the Alertify unit where the device is installed. */
|
|
173063
|
+
unit_id?: (string | undefined) | undefined
|
|
173064
|
+
/** Name of the Alertify unit where the device is installed. */
|
|
173065
|
+
unit_name?: (string | undefined) | undefined
|
|
173066
|
+
/** ID of the Alertify building that contains the unit. */
|
|
173067
|
+
building_id?: ((string | null) | undefined) | undefined
|
|
173068
|
+
}
|
|
173069
|
+
| undefined
|
|
173070
|
+
)
|
|
173071
|
+
| undefined
|
|
172738
173072
|
/** Metadata for a UniFi Protect camera. */
|
|
172739
173073
|
unifi_protect_metadata?:
|
|
172740
173074
|
| (
|
|
@@ -173033,11 +173367,11 @@ export type Routes = {
|
|
|
173033
173367
|
| undefined
|
|
173034
173368
|
} & {
|
|
173035
173369
|
/** Reported temperature in °F. */
|
|
173036
|
-
temperature_fahrenheit?:
|
|
173370
|
+
temperature_fahrenheit?: number | undefined
|
|
173037
173371
|
/** Reported temperature in °C. */
|
|
173038
|
-
temperature_celsius?:
|
|
173372
|
+
temperature_celsius?: number | undefined
|
|
173039
173373
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
173040
|
-
relative_humidity?:
|
|
173374
|
+
relative_humidity?: number | undefined
|
|
173041
173375
|
/** HVAC mode settings that the thermostat supports. */
|
|
173042
173376
|
available_hvac_mode_settings?:
|
|
173043
173377
|
('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined
|
|
@@ -173850,6 +174184,63 @@ export type Routes = {
|
|
|
173850
174184
|
image_url?: string | undefined
|
|
173851
174185
|
}
|
|
173852
174186
|
| undefined
|
|
174187
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
174188
|
+
temperature_celsius?: number | undefined
|
|
174189
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
174190
|
+
temperature_fahrenheit?: number | undefined
|
|
174191
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
174192
|
+
relative_humidity?: number | undefined
|
|
174193
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
174194
|
+
noise_level_decibels?: number | undefined
|
|
174195
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
174196
|
+
noise_level_nrs?: number | undefined
|
|
174197
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
174198
|
+
co2_ppm?: number | undefined
|
|
174199
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
174200
|
+
co_ppm?: number | undefined
|
|
174201
|
+
/** Air quality index, if the device measures it. */
|
|
174202
|
+
air_quality_index?: number | undefined
|
|
174203
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
174204
|
+
mold_risk_level?: string | undefined
|
|
174205
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
174206
|
+
is_occupied?: boolean | undefined
|
|
174207
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
174208
|
+
occupant_count?: number | undefined
|
|
174209
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
174210
|
+
is_smoking_detected?: boolean | undefined
|
|
174211
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
174212
|
+
named_sensors?:
|
|
174213
|
+
| {
|
|
174214
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
174215
|
+
sensor_name: string
|
|
174216
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
174217
|
+
display_name: string
|
|
174218
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
174219
|
+
temperature_celsius?: number | undefined
|
|
174220
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
174221
|
+
temperature_fahrenheit?: number | undefined
|
|
174222
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
174223
|
+
relative_humidity?: number | undefined
|
|
174224
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
174225
|
+
noise_level_decibels?: number | undefined
|
|
174226
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
174227
|
+
noise_level_nrs?: number | undefined
|
|
174228
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
174229
|
+
co2_ppm?: number | undefined
|
|
174230
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
174231
|
+
co_ppm?: number | undefined
|
|
174232
|
+
/** Air quality index, if the device measures it. */
|
|
174233
|
+
air_quality_index?: number | undefined
|
|
174234
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
174235
|
+
mold_risk_level?: string | undefined
|
|
174236
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
174237
|
+
is_occupied?: boolean | undefined
|
|
174238
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
174239
|
+
occupant_count?: number | undefined
|
|
174240
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
174241
|
+
is_smoking_detected?: boolean | undefined
|
|
174242
|
+
}[]
|
|
174243
|
+
| undefined
|
|
173853
174244
|
/** Indicates whether the device supports remote unlocking. */
|
|
173854
174245
|
can_remotely_unlock?: boolean | undefined
|
|
173855
174246
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -185340,6 +185731,7 @@ export type Routes = {
|
|
|
185340
185731
|
| 'unifi_protect_camera'
|
|
185341
185732
|
)
|
|
185342
185733
|
| 'sonos_speaker'
|
|
185734
|
+
| 'alertify_sensor'
|
|
185343
185735
|
/** IDs of the spaces the device is in. */
|
|
185344
185736
|
space_ids: string[]
|
|
185345
185737
|
/** Optional nickname to describe the device, settable through Seam. */
|
|
@@ -185448,58 +185840,9 @@ export type Routes = {
|
|
|
185448
185840
|
* @deprecated use offline_access_codes_enabled*/
|
|
185449
185841
|
supports_offline_access_codes?: boolean | undefined
|
|
185450
185842
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
185451
|
-
noise_level_decibels?:
|
|
185843
|
+
noise_level_decibels?: number | undefined
|
|
185452
185844
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
185453
185845
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
185454
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
185455
|
-
noise_level_nrs?: (number | null) | undefined
|
|
185456
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
185457
|
-
co2_ppm?: (number | null) | undefined
|
|
185458
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
185459
|
-
co_ppm?: (number | null) | undefined
|
|
185460
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
185461
|
-
air_quality_index?: (number | null) | undefined
|
|
185462
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
185463
|
-
mold_risk_level?: (string | null) | undefined
|
|
185464
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
185465
|
-
is_occupied?: (boolean | null) | undefined
|
|
185466
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
185467
|
-
occupant_count?: (number | null) | undefined
|
|
185468
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
185469
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
185470
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
185471
|
-
named_sensors?:
|
|
185472
|
-
| {
|
|
185473
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
185474
|
-
sensor_name: string
|
|
185475
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
185476
|
-
display_name: string
|
|
185477
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
185478
|
-
temperature_celsius?: (number | null) | undefined
|
|
185479
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
185480
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
185481
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
185482
|
-
relative_humidity?: (number | null) | undefined
|
|
185483
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
185484
|
-
noise_level_decibels?: (number | null) | undefined
|
|
185485
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
185486
|
-
noise_level_nrs?: (number | null) | undefined
|
|
185487
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
185488
|
-
co2_ppm?: (number | null) | undefined
|
|
185489
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
185490
|
-
co_ppm?: (number | null) | undefined
|
|
185491
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
185492
|
-
air_quality_index?: (number | null) | undefined
|
|
185493
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
185494
|
-
mold_risk_level?: (string | null) | undefined
|
|
185495
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
185496
|
-
is_occupied?: (boolean | null) | undefined
|
|
185497
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
185498
|
-
occupant_count?: (number | null) | undefined
|
|
185499
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
185500
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
185501
|
-
}[]
|
|
185502
|
-
| undefined
|
|
185503
185846
|
} & {
|
|
185504
185847
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
185505
185848
|
assa_abloy_credential_service_metadata?:
|
|
@@ -186241,6 +186584,24 @@ export type Routes = {
|
|
|
186241
186584
|
| undefined
|
|
186242
186585
|
)
|
|
186243
186586
|
| undefined
|
|
186587
|
+
/** Metadata for an Alertify sensor. */
|
|
186588
|
+
alertify_metadata?:
|
|
186589
|
+
| (
|
|
186590
|
+
| {
|
|
186591
|
+
/** Device ID reported by Alertify. */
|
|
186592
|
+
device_id?: (string | undefined) | undefined
|
|
186593
|
+
/** Device name, as set in the Alertify dashboard. */
|
|
186594
|
+
device_name?: (string | undefined) | undefined
|
|
186595
|
+
/** ID of the Alertify unit where the device is installed. */
|
|
186596
|
+
unit_id?: (string | undefined) | undefined
|
|
186597
|
+
/** Name of the Alertify unit where the device is installed. */
|
|
186598
|
+
unit_name?: (string | undefined) | undefined
|
|
186599
|
+
/** ID of the Alertify building that contains the unit. */
|
|
186600
|
+
building_id?: ((string | null) | undefined) | undefined
|
|
186601
|
+
}
|
|
186602
|
+
| undefined
|
|
186603
|
+
)
|
|
186604
|
+
| undefined
|
|
186244
186605
|
/** Metadata for a UniFi Protect camera. */
|
|
186245
186606
|
unifi_protect_metadata?:
|
|
186246
186607
|
| (
|
|
@@ -186539,11 +186900,11 @@ export type Routes = {
|
|
|
186539
186900
|
| undefined
|
|
186540
186901
|
} & {
|
|
186541
186902
|
/** Reported temperature in °F. */
|
|
186542
|
-
temperature_fahrenheit?:
|
|
186903
|
+
temperature_fahrenheit?: number | undefined
|
|
186543
186904
|
/** Reported temperature in °C. */
|
|
186544
|
-
temperature_celsius?:
|
|
186905
|
+
temperature_celsius?: number | undefined
|
|
186545
186906
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
186546
|
-
relative_humidity?:
|
|
186907
|
+
relative_humidity?: number | undefined
|
|
186547
186908
|
/** HVAC mode settings that the thermostat supports. */
|
|
186548
186909
|
available_hvac_mode_settings?:
|
|
186549
186910
|
('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined
|
|
@@ -187356,6 +187717,63 @@ export type Routes = {
|
|
|
187356
187717
|
image_url?: string | undefined
|
|
187357
187718
|
}
|
|
187358
187719
|
| undefined
|
|
187720
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
187721
|
+
temperature_celsius?: number | undefined
|
|
187722
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
187723
|
+
temperature_fahrenheit?: number | undefined
|
|
187724
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
187725
|
+
relative_humidity?: number | undefined
|
|
187726
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
187727
|
+
noise_level_decibels?: number | undefined
|
|
187728
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
187729
|
+
noise_level_nrs?: number | undefined
|
|
187730
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
187731
|
+
co2_ppm?: number | undefined
|
|
187732
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
187733
|
+
co_ppm?: number | undefined
|
|
187734
|
+
/** Air quality index, if the device measures it. */
|
|
187735
|
+
air_quality_index?: number | undefined
|
|
187736
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
187737
|
+
mold_risk_level?: string | undefined
|
|
187738
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
187739
|
+
is_occupied?: boolean | undefined
|
|
187740
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
187741
|
+
occupant_count?: number | undefined
|
|
187742
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
187743
|
+
is_smoking_detected?: boolean | undefined
|
|
187744
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
187745
|
+
named_sensors?:
|
|
187746
|
+
| {
|
|
187747
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
187748
|
+
sensor_name: string
|
|
187749
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
187750
|
+
display_name: string
|
|
187751
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
187752
|
+
temperature_celsius?: number | undefined
|
|
187753
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
187754
|
+
temperature_fahrenheit?: number | undefined
|
|
187755
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
187756
|
+
relative_humidity?: number | undefined
|
|
187757
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
187758
|
+
noise_level_decibels?: number | undefined
|
|
187759
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
187760
|
+
noise_level_nrs?: number | undefined
|
|
187761
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
187762
|
+
co2_ppm?: number | undefined
|
|
187763
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
187764
|
+
co_ppm?: number | undefined
|
|
187765
|
+
/** Air quality index, if the device measures it. */
|
|
187766
|
+
air_quality_index?: number | undefined
|
|
187767
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
187768
|
+
mold_risk_level?: string | undefined
|
|
187769
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
187770
|
+
is_occupied?: boolean | undefined
|
|
187771
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
187772
|
+
occupant_count?: number | undefined
|
|
187773
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
187774
|
+
is_smoking_detected?: boolean | undefined
|
|
187775
|
+
}[]
|
|
187776
|
+
| undefined
|
|
187359
187777
|
/** Indicates whether the device supports remote unlocking. */
|
|
187360
187778
|
can_remotely_unlock?: boolean | undefined
|
|
187361
187779
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -187481,6 +187899,7 @@ export type Routes = {
|
|
|
187481
187899
|
| 'unifi_protect_camera'
|
|
187482
187900
|
)
|
|
187483
187901
|
| 'sonos_speaker'
|
|
187902
|
+
| 'alertify_sensor'
|
|
187484
187903
|
/** IDs of the spaces the device is in. */
|
|
187485
187904
|
space_ids: string[]
|
|
187486
187905
|
/** Optional nickname to describe the device, settable through Seam. */
|
|
@@ -187589,58 +188008,9 @@ export type Routes = {
|
|
|
187589
188008
|
* @deprecated use offline_access_codes_enabled*/
|
|
187590
188009
|
supports_offline_access_codes?: boolean | undefined
|
|
187591
188010
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
187592
|
-
noise_level_decibels?:
|
|
188011
|
+
noise_level_decibels?: number | undefined
|
|
187593
188012
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
187594
188013
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
187595
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
187596
|
-
noise_level_nrs?: (number | null) | undefined
|
|
187597
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
187598
|
-
co2_ppm?: (number | null) | undefined
|
|
187599
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
187600
|
-
co_ppm?: (number | null) | undefined
|
|
187601
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
187602
|
-
air_quality_index?: (number | null) | undefined
|
|
187603
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
187604
|
-
mold_risk_level?: (string | null) | undefined
|
|
187605
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
187606
|
-
is_occupied?: (boolean | null) | undefined
|
|
187607
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
187608
|
-
occupant_count?: (number | null) | undefined
|
|
187609
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
187610
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
187611
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
187612
|
-
named_sensors?:
|
|
187613
|
-
| {
|
|
187614
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
187615
|
-
sensor_name: string
|
|
187616
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
187617
|
-
display_name: string
|
|
187618
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
187619
|
-
temperature_celsius?: (number | null) | undefined
|
|
187620
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
187621
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
187622
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
187623
|
-
relative_humidity?: (number | null) | undefined
|
|
187624
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
187625
|
-
noise_level_decibels?: (number | null) | undefined
|
|
187626
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
187627
|
-
noise_level_nrs?: (number | null) | undefined
|
|
187628
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
187629
|
-
co2_ppm?: (number | null) | undefined
|
|
187630
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
187631
|
-
co_ppm?: (number | null) | undefined
|
|
187632
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
187633
|
-
air_quality_index?: (number | null) | undefined
|
|
187634
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
187635
|
-
mold_risk_level?: (string | null) | undefined
|
|
187636
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
187637
|
-
is_occupied?: (boolean | null) | undefined
|
|
187638
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
187639
|
-
occupant_count?: (number | null) | undefined
|
|
187640
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
187641
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
187642
|
-
}[]
|
|
187643
|
-
| undefined
|
|
187644
188014
|
} & {
|
|
187645
188015
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
187646
188016
|
assa_abloy_credential_service_metadata?:
|
|
@@ -188382,6 +188752,24 @@ export type Routes = {
|
|
|
188382
188752
|
| undefined
|
|
188383
188753
|
)
|
|
188384
188754
|
| undefined
|
|
188755
|
+
/** Metadata for an Alertify sensor. */
|
|
188756
|
+
alertify_metadata?:
|
|
188757
|
+
| (
|
|
188758
|
+
| {
|
|
188759
|
+
/** Device ID reported by Alertify. */
|
|
188760
|
+
device_id?: (string | undefined) | undefined
|
|
188761
|
+
/** Device name, as set in the Alertify dashboard. */
|
|
188762
|
+
device_name?: (string | undefined) | undefined
|
|
188763
|
+
/** ID of the Alertify unit where the device is installed. */
|
|
188764
|
+
unit_id?: (string | undefined) | undefined
|
|
188765
|
+
/** Name of the Alertify unit where the device is installed. */
|
|
188766
|
+
unit_name?: (string | undefined) | undefined
|
|
188767
|
+
/** ID of the Alertify building that contains the unit. */
|
|
188768
|
+
building_id?: ((string | null) | undefined) | undefined
|
|
188769
|
+
}
|
|
188770
|
+
| undefined
|
|
188771
|
+
)
|
|
188772
|
+
| undefined
|
|
188385
188773
|
/** Metadata for a UniFi Protect camera. */
|
|
188386
188774
|
unifi_protect_metadata?:
|
|
188387
188775
|
| (
|
|
@@ -188680,11 +189068,11 @@ export type Routes = {
|
|
|
188680
189068
|
| undefined
|
|
188681
189069
|
} & {
|
|
188682
189070
|
/** Reported temperature in °F. */
|
|
188683
|
-
temperature_fahrenheit?:
|
|
189071
|
+
temperature_fahrenheit?: number | undefined
|
|
188684
189072
|
/** Reported temperature in °C. */
|
|
188685
|
-
temperature_celsius?:
|
|
189073
|
+
temperature_celsius?: number | undefined
|
|
188686
189074
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
188687
|
-
relative_humidity?:
|
|
189075
|
+
relative_humidity?: number | undefined
|
|
188688
189076
|
/** HVAC mode settings that the thermostat supports. */
|
|
188689
189077
|
available_hvac_mode_settings?:
|
|
188690
189078
|
('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined
|
|
@@ -189497,6 +189885,63 @@ export type Routes = {
|
|
|
189497
189885
|
image_url?: string | undefined
|
|
189498
189886
|
}
|
|
189499
189887
|
| undefined
|
|
189888
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
189889
|
+
temperature_celsius?: number | undefined
|
|
189890
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
189891
|
+
temperature_fahrenheit?: number | undefined
|
|
189892
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
189893
|
+
relative_humidity?: number | undefined
|
|
189894
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
189895
|
+
noise_level_decibels?: number | undefined
|
|
189896
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
189897
|
+
noise_level_nrs?: number | undefined
|
|
189898
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
189899
|
+
co2_ppm?: number | undefined
|
|
189900
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
189901
|
+
co_ppm?: number | undefined
|
|
189902
|
+
/** Air quality index, if the device measures it. */
|
|
189903
|
+
air_quality_index?: number | undefined
|
|
189904
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
189905
|
+
mold_risk_level?: string | undefined
|
|
189906
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
189907
|
+
is_occupied?: boolean | undefined
|
|
189908
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
189909
|
+
occupant_count?: number | undefined
|
|
189910
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
189911
|
+
is_smoking_detected?: boolean | undefined
|
|
189912
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
189913
|
+
named_sensors?:
|
|
189914
|
+
| {
|
|
189915
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
189916
|
+
sensor_name: string
|
|
189917
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
189918
|
+
display_name: string
|
|
189919
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
189920
|
+
temperature_celsius?: number | undefined
|
|
189921
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
189922
|
+
temperature_fahrenheit?: number | undefined
|
|
189923
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
189924
|
+
relative_humidity?: number | undefined
|
|
189925
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
189926
|
+
noise_level_decibels?: number | undefined
|
|
189927
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
189928
|
+
noise_level_nrs?: number | undefined
|
|
189929
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
189930
|
+
co2_ppm?: number | undefined
|
|
189931
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
189932
|
+
co_ppm?: number | undefined
|
|
189933
|
+
/** Air quality index, if the device measures it. */
|
|
189934
|
+
air_quality_index?: number | undefined
|
|
189935
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
189936
|
+
mold_risk_level?: string | undefined
|
|
189937
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
189938
|
+
is_occupied?: boolean | undefined
|
|
189939
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
189940
|
+
occupant_count?: number | undefined
|
|
189941
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
189942
|
+
is_smoking_detected?: boolean | undefined
|
|
189943
|
+
}[]
|
|
189944
|
+
| undefined
|
|
189500
189945
|
/** Indicates whether the device supports remote unlocking. */
|
|
189501
189946
|
can_remotely_unlock?: boolean | undefined
|
|
189502
189947
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -192337,6 +192782,7 @@ export type Routes = {
|
|
|
192337
192782
|
| 'unifi_protect_camera'
|
|
192338
192783
|
)
|
|
192339
192784
|
| 'sonos_speaker'
|
|
192785
|
+
| 'alertify_sensor'
|
|
192340
192786
|
/** IDs of the spaces the device is in. */
|
|
192341
192787
|
space_ids: string[]
|
|
192342
192788
|
/** Optional nickname to describe the device, settable through Seam. */
|
|
@@ -192445,58 +192891,9 @@ export type Routes = {
|
|
|
192445
192891
|
* @deprecated use offline_access_codes_enabled*/
|
|
192446
192892
|
supports_offline_access_codes?: boolean | undefined
|
|
192447
192893
|
/** Indicates current noise level in decibels, if the device supports noise detection. */
|
|
192448
|
-
noise_level_decibels?:
|
|
192894
|
+
noise_level_decibels?: number | undefined
|
|
192449
192895
|
/** Array of noise threshold IDs that are currently triggering. */
|
|
192450
192896
|
currently_triggering_noise_threshold_ids?: string[] | undefined
|
|
192451
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
192452
|
-
noise_level_nrs?: (number | null) | undefined
|
|
192453
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
192454
|
-
co2_ppm?: (number | null) | undefined
|
|
192455
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
192456
|
-
co_ppm?: (number | null) | undefined
|
|
192457
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
192458
|
-
air_quality_index?: (number | null) | undefined
|
|
192459
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
192460
|
-
mold_risk_level?: (string | null) | undefined
|
|
192461
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
192462
|
-
is_occupied?: (boolean | null) | undefined
|
|
192463
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
192464
|
-
occupant_count?: (number | null) | undefined
|
|
192465
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
192466
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
192467
|
-
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
192468
|
-
named_sensors?:
|
|
192469
|
-
| {
|
|
192470
|
-
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
192471
|
-
sensor_name: string
|
|
192472
|
-
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
192473
|
-
display_name: string
|
|
192474
|
-
/** Reported temperature in °C. `null` until the first value arrives. */
|
|
192475
|
-
temperature_celsius?: (number | null) | undefined
|
|
192476
|
-
/** Reported temperature in °F. `null` until the first value arrives. */
|
|
192477
|
-
temperature_fahrenheit?: (number | null) | undefined
|
|
192478
|
-
/** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
|
|
192479
|
-
relative_humidity?: (number | null) | undefined
|
|
192480
|
-
/** Noise level in decibels. `null` until the first value arrives. */
|
|
192481
|
-
noise_level_decibels?: (number | null) | undefined
|
|
192482
|
-
/** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
|
|
192483
|
-
noise_level_nrs?: (number | null) | undefined
|
|
192484
|
-
/** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
192485
|
-
co2_ppm?: (number | null) | undefined
|
|
192486
|
-
/** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
|
|
192487
|
-
co_ppm?: (number | null) | undefined
|
|
192488
|
-
/** Air quality index, if the device measures it. `null` until the first value arrives. */
|
|
192489
|
-
air_quality_index?: (number | null) | undefined
|
|
192490
|
-
/** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
|
|
192491
|
-
mold_risk_level?: (string | null) | undefined
|
|
192492
|
-
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
|
|
192493
|
-
is_occupied?: (boolean | null) | undefined
|
|
192494
|
-
/** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
|
|
192495
|
-
occupant_count?: (number | null) | undefined
|
|
192496
|
-
/** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
|
|
192497
|
-
is_smoking_detected?: (boolean | null) | undefined
|
|
192498
|
-
}[]
|
|
192499
|
-
| undefined
|
|
192500
192897
|
} & {
|
|
192501
192898
|
/** ASSA ABLOY Credential Service metadata for the phone. */
|
|
192502
192899
|
assa_abloy_credential_service_metadata?:
|
|
@@ -193263,6 +193660,25 @@ export type Routes = {
|
|
|
193263
193660
|
| undefined
|
|
193264
193661
|
)
|
|
193265
193662
|
| undefined
|
|
193663
|
+
/** Metadata for an Alertify sensor. */
|
|
193664
|
+
alertify_metadata?:
|
|
193665
|
+
| (
|
|
193666
|
+
| {
|
|
193667
|
+
/** Device ID reported by Alertify. */
|
|
193668
|
+
device_id?: (string | undefined) | undefined
|
|
193669
|
+
/** Device name, as set in the Alertify dashboard. */
|
|
193670
|
+
device_name?: (string | undefined) | undefined
|
|
193671
|
+
/** ID of the Alertify unit where the device is installed. */
|
|
193672
|
+
unit_id?: (string | undefined) | undefined
|
|
193673
|
+
/** Name of the Alertify unit where the device is installed. */
|
|
193674
|
+
unit_name?: (string | undefined) | undefined
|
|
193675
|
+
/** ID of the Alertify building that contains the unit. */
|
|
193676
|
+
building_id?:
|
|
193677
|
+
((string | null) | undefined) | undefined
|
|
193678
|
+
}
|
|
193679
|
+
| undefined
|
|
193680
|
+
)
|
|
193681
|
+
| undefined
|
|
193266
193682
|
/** Metadata for a UniFi Protect camera. */
|
|
193267
193683
|
unifi_protect_metadata?:
|
|
193268
193684
|
| (
|
|
@@ -193570,11 +193986,11 @@ export type Routes = {
|
|
|
193570
193986
|
| undefined
|
|
193571
193987
|
} & {
|
|
193572
193988
|
/** Reported temperature in °F. */
|
|
193573
|
-
temperature_fahrenheit?:
|
|
193989
|
+
temperature_fahrenheit?: number | undefined
|
|
193574
193990
|
/** Reported temperature in °C. */
|
|
193575
|
-
temperature_celsius?:
|
|
193991
|
+
temperature_celsius?: number | undefined
|
|
193576
193992
|
/** Reported relative humidity, as a value between 0 and 1, inclusive. */
|
|
193577
|
-
relative_humidity?:
|
|
193993
|
+
relative_humidity?: number | undefined
|
|
193578
193994
|
/** HVAC mode settings that the thermostat supports. */
|
|
193579
193995
|
available_hvac_mode_settings?:
|
|
193580
193996
|
| ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[]
|
|
@@ -194409,6 +194825,63 @@ export type Routes = {
|
|
|
194409
194825
|
image_url?: string | undefined
|
|
194410
194826
|
}
|
|
194411
194827
|
| undefined
|
|
194828
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
194829
|
+
temperature_celsius?: number | undefined
|
|
194830
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
194831
|
+
temperature_fahrenheit?: number | undefined
|
|
194832
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
194833
|
+
relative_humidity?: number | undefined
|
|
194834
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
194835
|
+
noise_level_decibels?: number | undefined
|
|
194836
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
194837
|
+
noise_level_nrs?: number | undefined
|
|
194838
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
194839
|
+
co2_ppm?: number | undefined
|
|
194840
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
194841
|
+
co_ppm?: number | undefined
|
|
194842
|
+
/** Air quality index, if the device measures it. */
|
|
194843
|
+
air_quality_index?: number | undefined
|
|
194844
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
194845
|
+
mold_risk_level?: string | undefined
|
|
194846
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
194847
|
+
is_occupied?: boolean | undefined
|
|
194848
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
194849
|
+
occupant_count?: number | undefined
|
|
194850
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
194851
|
+
is_smoking_detected?: boolean | undefined
|
|
194852
|
+
/** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
|
|
194853
|
+
named_sensors?:
|
|
194854
|
+
| {
|
|
194855
|
+
/** Stable, hardware-defined name of the sensor, such as a port number. */
|
|
194856
|
+
sensor_name: string
|
|
194857
|
+
/** Display name of the sensor. Defaults to `sensor_name`. */
|
|
194858
|
+
display_name: string
|
|
194859
|
+
/** Temperature in °C, if the device measures temperature. */
|
|
194860
|
+
temperature_celsius?: number | undefined
|
|
194861
|
+
/** Temperature in °F, if the device measures temperature. */
|
|
194862
|
+
temperature_fahrenheit?: number | undefined
|
|
194863
|
+
/** Relative humidity, as a value between 0 and 1, inclusive, if the device measures humidity. */
|
|
194864
|
+
relative_humidity?: number | undefined
|
|
194865
|
+
/** Noise level in decibels, if the device measures noise. */
|
|
194866
|
+
noise_level_decibels?: number | undefined
|
|
194867
|
+
/** Noise level as a Noise Risk Score (NRS), if the device reports one. */
|
|
194868
|
+
noise_level_nrs?: number | undefined
|
|
194869
|
+
/** Carbon dioxide concentration in parts per million, if the device measures it. */
|
|
194870
|
+
co2_ppm?: number | undefined
|
|
194871
|
+
/** Carbon monoxide concentration in parts per million, if the device measures it. */
|
|
194872
|
+
co_ppm?: number | undefined
|
|
194873
|
+
/** Air quality index, if the device measures it. */
|
|
194874
|
+
air_quality_index?: number | undefined
|
|
194875
|
+
/** Mold risk level as reported by the device, if the device measures it. */
|
|
194876
|
+
mold_risk_level?: string | undefined
|
|
194877
|
+
/** Indicates whether the device detects that the space is occupied, if the device measures occupancy. */
|
|
194878
|
+
is_occupied?: boolean | undefined
|
|
194879
|
+
/** Number of occupants the device detects, if the device counts occupants. */
|
|
194880
|
+
occupant_count?: number | undefined
|
|
194881
|
+
/** Indicates whether the device detects smoking, if the device measures it. */
|
|
194882
|
+
is_smoking_detected?: boolean | undefined
|
|
194883
|
+
}[]
|
|
194884
|
+
| undefined
|
|
194412
194885
|
/** Indicates whether the device supports remote unlocking. */
|
|
194413
194886
|
can_remotely_unlock?: boolean | undefined
|
|
194414
194887
|
/** Indicates whether the device supports remote locking. */
|
|
@@ -198656,6 +199129,7 @@ export type Routes = {
|
|
|
198656
199129
|
| 'unifi_protect_camera'
|
|
198657
199130
|
)
|
|
198658
199131
|
| 'sonos_speaker'
|
|
199132
|
+
| 'alertify_sensor'
|
|
198659
199133
|
/** Unique identifier for the account associated with the device. */
|
|
198660
199134
|
connected_account_id: string
|
|
198661
199135
|
/** Location information for the device. */
|