@seamapi/types 1.1184.0 → 1.1185.0

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
@@ -14186,9 +14186,56 @@ export type Routes = {
14186
14186
  * @deprecated use offline_access_codes_enabled*/
14187
14187
  supports_offline_access_codes?: boolean | undefined;
14188
14188
  /** Indicates current noise level in decibels, if the device supports noise detection. */
14189
- noise_level_decibels?: number | undefined;
14189
+ noise_level_decibels?: (number | null) | undefined;
14190
14190
  /** Array of noise threshold IDs that are currently triggering. */
14191
14191
  currently_triggering_noise_threshold_ids?: string[] | undefined;
14192
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
14193
+ noise_level_nrs?: (number | null) | undefined;
14194
+ /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
14195
+ co2_ppm?: (number | null) | undefined;
14196
+ /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
14197
+ co_ppm?: (number | null) | undefined;
14198
+ /** Air quality index, if the device measures it. `null` until the first value arrives. */
14199
+ air_quality_index?: (number | null) | undefined;
14200
+ /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
14201
+ mold_risk_level?: (string | null) | undefined;
14202
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
14203
+ is_occupied?: (boolean | null) | undefined;
14204
+ /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
14205
+ occupant_count?: (number | null) | undefined;
14206
+ /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
14207
+ is_smoking_detected?: (boolean | null) | undefined;
14208
+ /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
14209
+ named_sensors?: {
14210
+ /** Stable, hardware-defined name of the sensor, such as a port number. */
14211
+ sensor_name: string;
14212
+ /** Display name of the sensor. Defaults to `sensor_name`. */
14213
+ display_name: string;
14214
+ /** Reported temperature in °C. `null` until the first value arrives. */
14215
+ temperature_celsius?: (number | null) | undefined;
14216
+ /** Reported temperature in °F. `null` until the first value arrives. */
14217
+ temperature_fahrenheit?: (number | null) | undefined;
14218
+ /** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
14219
+ relative_humidity?: (number | null) | undefined;
14220
+ /** Noise level in decibels. `null` until the first value arrives. */
14221
+ noise_level_decibels?: (number | null) | undefined;
14222
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
14223
+ noise_level_nrs?: (number | null) | undefined;
14224
+ /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
14225
+ co2_ppm?: (number | null) | undefined;
14226
+ /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
14227
+ co_ppm?: (number | null) | undefined;
14228
+ /** Air quality index, if the device measures it. `null` until the first value arrives. */
14229
+ air_quality_index?: (number | null) | undefined;
14230
+ /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
14231
+ mold_risk_level?: (string | null) | undefined;
14232
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
14233
+ is_occupied?: (boolean | null) | undefined;
14234
+ /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
14235
+ occupant_count?: (number | null) | undefined;
14236
+ /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
14237
+ is_smoking_detected?: (boolean | null) | undefined;
14238
+ }[] | undefined;
14192
14239
  } & {
14193
14240
  /** ASSA ABLOY Credential Service metadata for the phone. */
14194
14241
  assa_abloy_credential_service_metadata?: ({
@@ -15020,11 +15067,11 @@ export type Routes = {
15020
15067
  } | undefined;
15021
15068
  } & {
15022
15069
  /** Reported temperature in °F. */
15023
- temperature_fahrenheit?: number | undefined;
15070
+ temperature_fahrenheit?: (number | null) | undefined;
15024
15071
  /** Reported temperature in °C. */
15025
- temperature_celsius?: number | undefined;
15072
+ temperature_celsius?: (number | null) | undefined;
15026
15073
  /** Reported relative humidity, as a value between 0 and 1, inclusive. */
15027
- relative_humidity?: number | undefined;
15074
+ relative_humidity?: (number | null) | undefined;
15028
15075
  /** HVAC mode settings that the thermostat supports. */
15029
15076
  available_hvac_mode_settings?: ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined;
15030
15077
  /** Fan mode settings that the thermostat supports. */
@@ -22426,9 +22473,56 @@ export type Routes = {
22426
22473
  * @deprecated use offline_access_codes_enabled*/
22427
22474
  supports_offline_access_codes?: boolean | undefined;
22428
22475
  /** Indicates current noise level in decibels, if the device supports noise detection. */
22429
- noise_level_decibels?: number | undefined;
22476
+ noise_level_decibels?: (number | null) | undefined;
22430
22477
  /** Array of noise threshold IDs that are currently triggering. */
22431
22478
  currently_triggering_noise_threshold_ids?: string[] | undefined;
22479
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
22480
+ noise_level_nrs?: (number | null) | undefined;
22481
+ /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
22482
+ co2_ppm?: (number | null) | undefined;
22483
+ /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
22484
+ co_ppm?: (number | null) | undefined;
22485
+ /** Air quality index, if the device measures it. `null` until the first value arrives. */
22486
+ air_quality_index?: (number | null) | undefined;
22487
+ /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
22488
+ mold_risk_level?: (string | null) | undefined;
22489
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
22490
+ is_occupied?: (boolean | null) | undefined;
22491
+ /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
22492
+ occupant_count?: (number | null) | undefined;
22493
+ /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
22494
+ is_smoking_detected?: (boolean | null) | undefined;
22495
+ /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
22496
+ named_sensors?: {
22497
+ /** Stable, hardware-defined name of the sensor, such as a port number. */
22498
+ sensor_name: string;
22499
+ /** Display name of the sensor. Defaults to `sensor_name`. */
22500
+ display_name: string;
22501
+ /** Reported temperature in °C. `null` until the first value arrives. */
22502
+ temperature_celsius?: (number | null) | undefined;
22503
+ /** Reported temperature in °F. `null` until the first value arrives. */
22504
+ temperature_fahrenheit?: (number | null) | undefined;
22505
+ /** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
22506
+ relative_humidity?: (number | null) | undefined;
22507
+ /** Noise level in decibels. `null` until the first value arrives. */
22508
+ noise_level_decibels?: (number | null) | undefined;
22509
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
22510
+ noise_level_nrs?: (number | null) | undefined;
22511
+ /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
22512
+ co2_ppm?: (number | null) | undefined;
22513
+ /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
22514
+ co_ppm?: (number | null) | undefined;
22515
+ /** Air quality index, if the device measures it. `null` until the first value arrives. */
22516
+ air_quality_index?: (number | null) | undefined;
22517
+ /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
22518
+ mold_risk_level?: (string | null) | undefined;
22519
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
22520
+ is_occupied?: (boolean | null) | undefined;
22521
+ /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
22522
+ occupant_count?: (number | null) | undefined;
22523
+ /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
22524
+ is_smoking_detected?: (boolean | null) | undefined;
22525
+ }[] | undefined;
22432
22526
  } & {
22433
22527
  /** ASSA ABLOY Credential Service metadata for the phone. */
22434
22528
  assa_abloy_credential_service_metadata?: ({
@@ -23260,11 +23354,11 @@ export type Routes = {
23260
23354
  } | undefined;
23261
23355
  } & {
23262
23356
  /** Reported temperature in °F. */
23263
- temperature_fahrenheit?: number | undefined;
23357
+ temperature_fahrenheit?: (number | null) | undefined;
23264
23358
  /** Reported temperature in °C. */
23265
- temperature_celsius?: number | undefined;
23359
+ temperature_celsius?: (number | null) | undefined;
23266
23360
  /** Reported relative humidity, as a value between 0 and 1, inclusive. */
23267
- relative_humidity?: number | undefined;
23361
+ relative_humidity?: (number | null) | undefined;
23268
23362
  /** HVAC mode settings that the thermostat supports. */
23269
23363
  available_hvac_mode_settings?: ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined;
23270
23364
  /** Fan mode settings that the thermostat supports. */
@@ -49918,9 +50012,56 @@ export type Routes = {
49918
50012
  * @deprecated use offline_access_codes_enabled*/
49919
50013
  supports_offline_access_codes?: boolean | undefined;
49920
50014
  /** Indicates current noise level in decibels, if the device supports noise detection. */
49921
- noise_level_decibels?: number | undefined;
50015
+ noise_level_decibels?: (number | null) | undefined;
49922
50016
  /** Array of noise threshold IDs that are currently triggering. */
49923
50017
  currently_triggering_noise_threshold_ids?: string[] | undefined;
50018
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
50019
+ noise_level_nrs?: (number | null) | undefined;
50020
+ /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
50021
+ co2_ppm?: (number | null) | undefined;
50022
+ /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
50023
+ co_ppm?: (number | null) | undefined;
50024
+ /** Air quality index, if the device measures it. `null` until the first value arrives. */
50025
+ air_quality_index?: (number | null) | undefined;
50026
+ /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
50027
+ mold_risk_level?: (string | null) | undefined;
50028
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
50029
+ is_occupied?: (boolean | null) | undefined;
50030
+ /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
50031
+ occupant_count?: (number | null) | undefined;
50032
+ /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
50033
+ is_smoking_detected?: (boolean | null) | undefined;
50034
+ /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
50035
+ named_sensors?: {
50036
+ /** Stable, hardware-defined name of the sensor, such as a port number. */
50037
+ sensor_name: string;
50038
+ /** Display name of the sensor. Defaults to `sensor_name`. */
50039
+ display_name: string;
50040
+ /** Reported temperature in °C. `null` until the first value arrives. */
50041
+ temperature_celsius?: (number | null) | undefined;
50042
+ /** Reported temperature in °F. `null` until the first value arrives. */
50043
+ temperature_fahrenheit?: (number | null) | undefined;
50044
+ /** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
50045
+ relative_humidity?: (number | null) | undefined;
50046
+ /** Noise level in decibels. `null` until the first value arrives. */
50047
+ noise_level_decibels?: (number | null) | undefined;
50048
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
50049
+ noise_level_nrs?: (number | null) | undefined;
50050
+ /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
50051
+ co2_ppm?: (number | null) | undefined;
50052
+ /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
50053
+ co_ppm?: (number | null) | undefined;
50054
+ /** Air quality index, if the device measures it. `null` until the first value arrives. */
50055
+ air_quality_index?: (number | null) | undefined;
50056
+ /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
50057
+ mold_risk_level?: (string | null) | undefined;
50058
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
50059
+ is_occupied?: (boolean | null) | undefined;
50060
+ /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
50061
+ occupant_count?: (number | null) | undefined;
50062
+ /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
50063
+ is_smoking_detected?: (boolean | null) | undefined;
50064
+ }[] | undefined;
49924
50065
  } & {
49925
50066
  /** ASSA ABLOY Credential Service metadata for the phone. */
49926
50067
  assa_abloy_credential_service_metadata?: ({
@@ -50752,11 +50893,11 @@ export type Routes = {
50752
50893
  } | undefined;
50753
50894
  } & {
50754
50895
  /** Reported temperature in °F. */
50755
- temperature_fahrenheit?: number | undefined;
50896
+ temperature_fahrenheit?: (number | null) | undefined;
50756
50897
  /** Reported temperature in °C. */
50757
- temperature_celsius?: number | undefined;
50898
+ temperature_celsius?: (number | null) | undefined;
50758
50899
  /** Reported relative humidity, as a value between 0 and 1, inclusive. */
50759
- relative_humidity?: number | undefined;
50900
+ relative_humidity?: (number | null) | undefined;
50760
50901
  /** HVAC mode settings that the thermostat supports. */
50761
50902
  available_hvac_mode_settings?: ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined;
50762
50903
  /** Fan mode settings that the thermostat supports. */
@@ -51634,9 +51775,56 @@ export type Routes = {
51634
51775
  * @deprecated use offline_access_codes_enabled*/
51635
51776
  supports_offline_access_codes?: boolean | undefined;
51636
51777
  /** Indicates current noise level in decibels, if the device supports noise detection. */
51637
- noise_level_decibels?: number | undefined;
51778
+ noise_level_decibels?: (number | null) | undefined;
51638
51779
  /** Array of noise threshold IDs that are currently triggering. */
51639
51780
  currently_triggering_noise_threshold_ids?: string[] | undefined;
51781
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
51782
+ noise_level_nrs?: (number | null) | undefined;
51783
+ /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
51784
+ co2_ppm?: (number | null) | undefined;
51785
+ /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
51786
+ co_ppm?: (number | null) | undefined;
51787
+ /** Air quality index, if the device measures it. `null` until the first value arrives. */
51788
+ air_quality_index?: (number | null) | undefined;
51789
+ /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
51790
+ mold_risk_level?: (string | null) | undefined;
51791
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
51792
+ is_occupied?: (boolean | null) | undefined;
51793
+ /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
51794
+ occupant_count?: (number | null) | undefined;
51795
+ /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
51796
+ is_smoking_detected?: (boolean | null) | undefined;
51797
+ /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
51798
+ named_sensors?: {
51799
+ /** Stable, hardware-defined name of the sensor, such as a port number. */
51800
+ sensor_name: string;
51801
+ /** Display name of the sensor. Defaults to `sensor_name`. */
51802
+ display_name: string;
51803
+ /** Reported temperature in °C. `null` until the first value arrives. */
51804
+ temperature_celsius?: (number | null) | undefined;
51805
+ /** Reported temperature in °F. `null` until the first value arrives. */
51806
+ temperature_fahrenheit?: (number | null) | undefined;
51807
+ /** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
51808
+ relative_humidity?: (number | null) | undefined;
51809
+ /** Noise level in decibels. `null` until the first value arrives. */
51810
+ noise_level_decibels?: (number | null) | undefined;
51811
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
51812
+ noise_level_nrs?: (number | null) | undefined;
51813
+ /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
51814
+ co2_ppm?: (number | null) | undefined;
51815
+ /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
51816
+ co_ppm?: (number | null) | undefined;
51817
+ /** Air quality index, if the device measures it. `null` until the first value arrives. */
51818
+ air_quality_index?: (number | null) | undefined;
51819
+ /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
51820
+ mold_risk_level?: (string | null) | undefined;
51821
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
51822
+ is_occupied?: (boolean | null) | undefined;
51823
+ /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
51824
+ occupant_count?: (number | null) | undefined;
51825
+ /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
51826
+ is_smoking_detected?: (boolean | null) | undefined;
51827
+ }[] | undefined;
51640
51828
  } & {
51641
51829
  /** ASSA ABLOY Credential Service metadata for the phone. */
51642
51830
  assa_abloy_credential_service_metadata?: ({
@@ -52468,11 +52656,11 @@ export type Routes = {
52468
52656
  } | undefined;
52469
52657
  } & {
52470
52658
  /** Reported temperature in °F. */
52471
- temperature_fahrenheit?: number | undefined;
52659
+ temperature_fahrenheit?: (number | null) | undefined;
52472
52660
  /** Reported temperature in °C. */
52473
- temperature_celsius?: number | undefined;
52661
+ temperature_celsius?: (number | null) | undefined;
52474
52662
  /** Reported relative humidity, as a value between 0 and 1, inclusive. */
52475
- relative_humidity?: number | undefined;
52663
+ relative_humidity?: (number | null) | undefined;
52476
52664
  /** HVAC mode settings that the thermostat supports. */
52477
52665
  available_hvac_mode_settings?: ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined;
52478
52666
  /** Fan mode settings that the thermostat supports. */
@@ -64591,9 +64779,56 @@ export type Routes = {
64591
64779
  * @deprecated use offline_access_codes_enabled*/
64592
64780
  supports_offline_access_codes?: boolean | undefined;
64593
64781
  /** Indicates current noise level in decibels, if the device supports noise detection. */
64594
- noise_level_decibels?: number | undefined;
64782
+ noise_level_decibels?: (number | null) | undefined;
64595
64783
  /** Array of noise threshold IDs that are currently triggering. */
64596
64784
  currently_triggering_noise_threshold_ids?: string[] | undefined;
64785
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
64786
+ noise_level_nrs?: (number | null) | undefined;
64787
+ /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
64788
+ co2_ppm?: (number | null) | undefined;
64789
+ /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
64790
+ co_ppm?: (number | null) | undefined;
64791
+ /** Air quality index, if the device measures it. `null` until the first value arrives. */
64792
+ air_quality_index?: (number | null) | undefined;
64793
+ /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
64794
+ mold_risk_level?: (string | null) | undefined;
64795
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
64796
+ is_occupied?: (boolean | null) | undefined;
64797
+ /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
64798
+ occupant_count?: (number | null) | undefined;
64799
+ /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
64800
+ is_smoking_detected?: (boolean | null) | undefined;
64801
+ /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
64802
+ named_sensors?: {
64803
+ /** Stable, hardware-defined name of the sensor, such as a port number. */
64804
+ sensor_name: string;
64805
+ /** Display name of the sensor. Defaults to `sensor_name`. */
64806
+ display_name: string;
64807
+ /** Reported temperature in °C. `null` until the first value arrives. */
64808
+ temperature_celsius?: (number | null) | undefined;
64809
+ /** Reported temperature in °F. `null` until the first value arrives. */
64810
+ temperature_fahrenheit?: (number | null) | undefined;
64811
+ /** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
64812
+ relative_humidity?: (number | null) | undefined;
64813
+ /** Noise level in decibels. `null` until the first value arrives. */
64814
+ noise_level_decibels?: (number | null) | undefined;
64815
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
64816
+ noise_level_nrs?: (number | null) | undefined;
64817
+ /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
64818
+ co2_ppm?: (number | null) | undefined;
64819
+ /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
64820
+ co_ppm?: (number | null) | undefined;
64821
+ /** Air quality index, if the device measures it. `null` until the first value arrives. */
64822
+ air_quality_index?: (number | null) | undefined;
64823
+ /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
64824
+ mold_risk_level?: (string | null) | undefined;
64825
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
64826
+ is_occupied?: (boolean | null) | undefined;
64827
+ /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
64828
+ occupant_count?: (number | null) | undefined;
64829
+ /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
64830
+ is_smoking_detected?: (boolean | null) | undefined;
64831
+ }[] | undefined;
64597
64832
  } & {
64598
64833
  /** ASSA ABLOY Credential Service metadata for the phone. */
64599
64834
  assa_abloy_credential_service_metadata?: ({
@@ -65425,11 +65660,11 @@ export type Routes = {
65425
65660
  } | undefined;
65426
65661
  } & {
65427
65662
  /** Reported temperature in °F. */
65428
- temperature_fahrenheit?: number | undefined;
65663
+ temperature_fahrenheit?: (number | null) | undefined;
65429
65664
  /** Reported temperature in °C. */
65430
- temperature_celsius?: number | undefined;
65665
+ temperature_celsius?: (number | null) | undefined;
65431
65666
  /** Reported relative humidity, as a value between 0 and 1, inclusive. */
65432
- relative_humidity?: number | undefined;
65667
+ relative_humidity?: (number | null) | undefined;
65433
65668
  /** HVAC mode settings that the thermostat supports. */
65434
65669
  available_hvac_mode_settings?: ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined;
65435
65670
  /** Fan mode settings that the thermostat supports. */
@@ -66257,9 +66492,56 @@ export type Routes = {
66257
66492
  * @deprecated use offline_access_codes_enabled*/
66258
66493
  supports_offline_access_codes?: boolean | undefined;
66259
66494
  /** Indicates current noise level in decibels, if the device supports noise detection. */
66260
- noise_level_decibels?: number | undefined;
66495
+ noise_level_decibels?: (number | null) | undefined;
66261
66496
  /** Array of noise threshold IDs that are currently triggering. */
66262
66497
  currently_triggering_noise_threshold_ids?: string[] | undefined;
66498
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
66499
+ noise_level_nrs?: (number | null) | undefined;
66500
+ /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
66501
+ co2_ppm?: (number | null) | undefined;
66502
+ /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
66503
+ co_ppm?: (number | null) | undefined;
66504
+ /** Air quality index, if the device measures it. `null` until the first value arrives. */
66505
+ air_quality_index?: (number | null) | undefined;
66506
+ /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
66507
+ mold_risk_level?: (string | null) | undefined;
66508
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
66509
+ is_occupied?: (boolean | null) | undefined;
66510
+ /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
66511
+ occupant_count?: (number | null) | undefined;
66512
+ /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
66513
+ is_smoking_detected?: (boolean | null) | undefined;
66514
+ /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
66515
+ named_sensors?: {
66516
+ /** Stable, hardware-defined name of the sensor, such as a port number. */
66517
+ sensor_name: string;
66518
+ /** Display name of the sensor. Defaults to `sensor_name`. */
66519
+ display_name: string;
66520
+ /** Reported temperature in °C. `null` until the first value arrives. */
66521
+ temperature_celsius?: (number | null) | undefined;
66522
+ /** Reported temperature in °F. `null` until the first value arrives. */
66523
+ temperature_fahrenheit?: (number | null) | undefined;
66524
+ /** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
66525
+ relative_humidity?: (number | null) | undefined;
66526
+ /** Noise level in decibels. `null` until the first value arrives. */
66527
+ noise_level_decibels?: (number | null) | undefined;
66528
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
66529
+ noise_level_nrs?: (number | null) | undefined;
66530
+ /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
66531
+ co2_ppm?: (number | null) | undefined;
66532
+ /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
66533
+ co_ppm?: (number | null) | undefined;
66534
+ /** Air quality index, if the device measures it. `null` until the first value arrives. */
66535
+ air_quality_index?: (number | null) | undefined;
66536
+ /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
66537
+ mold_risk_level?: (string | null) | undefined;
66538
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
66539
+ is_occupied?: (boolean | null) | undefined;
66540
+ /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
66541
+ occupant_count?: (number | null) | undefined;
66542
+ /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
66543
+ is_smoking_detected?: (boolean | null) | undefined;
66544
+ }[] | undefined;
66263
66545
  } & {
66264
66546
  /** ASSA ABLOY Credential Service metadata for the phone. */
66265
66547
  assa_abloy_credential_service_metadata?: ({
@@ -67091,11 +67373,11 @@ export type Routes = {
67091
67373
  } | undefined;
67092
67374
  } & {
67093
67375
  /** Reported temperature in °F. */
67094
- temperature_fahrenheit?: number | undefined;
67376
+ temperature_fahrenheit?: (number | null) | undefined;
67095
67377
  /** Reported temperature in °C. */
67096
- temperature_celsius?: number | undefined;
67378
+ temperature_celsius?: (number | null) | undefined;
67097
67379
  /** Reported relative humidity, as a value between 0 and 1, inclusive. */
67098
- relative_humidity?: number | undefined;
67380
+ relative_humidity?: (number | null) | undefined;
67099
67381
  /** HVAC mode settings that the thermostat supports. */
67100
67382
  available_hvac_mode_settings?: ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined;
67101
67383
  /** Fan mode settings that the thermostat supports. */
@@ -67946,9 +68228,56 @@ export type Routes = {
67946
68228
  * @deprecated use offline_access_codes_enabled*/
67947
68229
  supports_offline_access_codes?: boolean | undefined;
67948
68230
  /** Indicates current noise level in decibels, if the device supports noise detection. */
67949
- noise_level_decibels?: number | undefined;
68231
+ noise_level_decibels?: (number | null) | undefined;
67950
68232
  /** Array of noise threshold IDs that are currently triggering. */
67951
68233
  currently_triggering_noise_threshold_ids?: string[] | undefined;
68234
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
68235
+ noise_level_nrs?: (number | null) | undefined;
68236
+ /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
68237
+ co2_ppm?: (number | null) | undefined;
68238
+ /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
68239
+ co_ppm?: (number | null) | undefined;
68240
+ /** Air quality index, if the device measures it. `null` until the first value arrives. */
68241
+ air_quality_index?: (number | null) | undefined;
68242
+ /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
68243
+ mold_risk_level?: (string | null) | undefined;
68244
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
68245
+ is_occupied?: (boolean | null) | undefined;
68246
+ /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
68247
+ occupant_count?: (number | null) | undefined;
68248
+ /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
68249
+ is_smoking_detected?: (boolean | null) | undefined;
68250
+ /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
68251
+ named_sensors?: {
68252
+ /** Stable, hardware-defined name of the sensor, such as a port number. */
68253
+ sensor_name: string;
68254
+ /** Display name of the sensor. Defaults to `sensor_name`. */
68255
+ display_name: string;
68256
+ /** Reported temperature in °C. `null` until the first value arrives. */
68257
+ temperature_celsius?: (number | null) | undefined;
68258
+ /** Reported temperature in °F. `null` until the first value arrives. */
68259
+ temperature_fahrenheit?: (number | null) | undefined;
68260
+ /** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
68261
+ relative_humidity?: (number | null) | undefined;
68262
+ /** Noise level in decibels. `null` until the first value arrives. */
68263
+ noise_level_decibels?: (number | null) | undefined;
68264
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
68265
+ noise_level_nrs?: (number | null) | undefined;
68266
+ /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
68267
+ co2_ppm?: (number | null) | undefined;
68268
+ /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
68269
+ co_ppm?: (number | null) | undefined;
68270
+ /** Air quality index, if the device measures it. `null` until the first value arrives. */
68271
+ air_quality_index?: (number | null) | undefined;
68272
+ /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
68273
+ mold_risk_level?: (string | null) | undefined;
68274
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
68275
+ is_occupied?: (boolean | null) | undefined;
68276
+ /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
68277
+ occupant_count?: (number | null) | undefined;
68278
+ /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
68279
+ is_smoking_detected?: (boolean | null) | undefined;
68280
+ }[] | undefined;
67952
68281
  } & {
67953
68282
  /** ASSA ABLOY Credential Service metadata for the phone. */
67954
68283
  assa_abloy_credential_service_metadata?: ({
@@ -68780,11 +69109,11 @@ export type Routes = {
68780
69109
  } | undefined;
68781
69110
  } & {
68782
69111
  /** Reported temperature in °F. */
68783
- temperature_fahrenheit?: number | undefined;
69112
+ temperature_fahrenheit?: (number | null) | undefined;
68784
69113
  /** Reported temperature in °C. */
68785
- temperature_celsius?: number | undefined;
69114
+ temperature_celsius?: (number | null) | undefined;
68786
69115
  /** Reported relative humidity, as a value between 0 and 1, inclusive. */
68787
- relative_humidity?: number | undefined;
69116
+ relative_humidity?: (number | null) | undefined;
68788
69117
  /** HVAC mode settings that the thermostat supports. */
68789
69118
  available_hvac_mode_settings?: ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined;
68790
69119
  /** Fan mode settings that the thermostat supports. */
@@ -69611,9 +69940,56 @@ export type Routes = {
69611
69940
  * @deprecated use offline_access_codes_enabled*/
69612
69941
  supports_offline_access_codes?: boolean | undefined;
69613
69942
  /** Indicates current noise level in decibels, if the device supports noise detection. */
69614
- noise_level_decibels?: number | undefined;
69943
+ noise_level_decibels?: (number | null) | undefined;
69615
69944
  /** Array of noise threshold IDs that are currently triggering. */
69616
69945
  currently_triggering_noise_threshold_ids?: string[] | undefined;
69946
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
69947
+ noise_level_nrs?: (number | null) | undefined;
69948
+ /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
69949
+ co2_ppm?: (number | null) | undefined;
69950
+ /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
69951
+ co_ppm?: (number | null) | undefined;
69952
+ /** Air quality index, if the device measures it. `null` until the first value arrives. */
69953
+ air_quality_index?: (number | null) | undefined;
69954
+ /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
69955
+ mold_risk_level?: (string | null) | undefined;
69956
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
69957
+ is_occupied?: (boolean | null) | undefined;
69958
+ /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
69959
+ occupant_count?: (number | null) | undefined;
69960
+ /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
69961
+ is_smoking_detected?: (boolean | null) | undefined;
69962
+ /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
69963
+ named_sensors?: {
69964
+ /** Stable, hardware-defined name of the sensor, such as a port number. */
69965
+ sensor_name: string;
69966
+ /** Display name of the sensor. Defaults to `sensor_name`. */
69967
+ display_name: string;
69968
+ /** Reported temperature in °C. `null` until the first value arrives. */
69969
+ temperature_celsius?: (number | null) | undefined;
69970
+ /** Reported temperature in °F. `null` until the first value arrives. */
69971
+ temperature_fahrenheit?: (number | null) | undefined;
69972
+ /** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
69973
+ relative_humidity?: (number | null) | undefined;
69974
+ /** Noise level in decibels. `null` until the first value arrives. */
69975
+ noise_level_decibels?: (number | null) | undefined;
69976
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
69977
+ noise_level_nrs?: (number | null) | undefined;
69978
+ /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
69979
+ co2_ppm?: (number | null) | undefined;
69980
+ /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
69981
+ co_ppm?: (number | null) | undefined;
69982
+ /** Air quality index, if the device measures it. `null` until the first value arrives. */
69983
+ air_quality_index?: (number | null) | undefined;
69984
+ /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
69985
+ mold_risk_level?: (string | null) | undefined;
69986
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
69987
+ is_occupied?: (boolean | null) | undefined;
69988
+ /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
69989
+ occupant_count?: (number | null) | undefined;
69990
+ /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
69991
+ is_smoking_detected?: (boolean | null) | undefined;
69992
+ }[] | undefined;
69617
69993
  } & {
69618
69994
  /** ASSA ABLOY Credential Service metadata for the phone. */
69619
69995
  assa_abloy_credential_service_metadata?: ({
@@ -70445,11 +70821,11 @@ export type Routes = {
70445
70821
  } | undefined;
70446
70822
  } & {
70447
70823
  /** Reported temperature in °F. */
70448
- temperature_fahrenheit?: number | undefined;
70824
+ temperature_fahrenheit?: (number | null) | undefined;
70449
70825
  /** Reported temperature in °C. */
70450
- temperature_celsius?: number | undefined;
70826
+ temperature_celsius?: (number | null) | undefined;
70451
70827
  /** Reported relative humidity, as a value between 0 and 1, inclusive. */
70452
- relative_humidity?: number | undefined;
70828
+ relative_humidity?: (number | null) | undefined;
70453
70829
  /** HVAC mode settings that the thermostat supports. */
70454
70830
  available_hvac_mode_settings?: ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined;
70455
70831
  /** Fan mode settings that the thermostat supports. */
@@ -80151,9 +80527,56 @@ export type Routes = {
80151
80527
  * @deprecated use offline_access_codes_enabled*/
80152
80528
  supports_offline_access_codes?: boolean | undefined;
80153
80529
  /** Indicates current noise level in decibels, if the device supports noise detection. */
80154
- noise_level_decibels?: number | undefined;
80530
+ noise_level_decibels?: (number | null) | undefined;
80155
80531
  /** Array of noise threshold IDs that are currently triggering. */
80156
80532
  currently_triggering_noise_threshold_ids?: string[] | undefined;
80533
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
80534
+ noise_level_nrs?: (number | null) | undefined;
80535
+ /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
80536
+ co2_ppm?: (number | null) | undefined;
80537
+ /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
80538
+ co_ppm?: (number | null) | undefined;
80539
+ /** Air quality index, if the device measures it. `null` until the first value arrives. */
80540
+ air_quality_index?: (number | null) | undefined;
80541
+ /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
80542
+ mold_risk_level?: (string | null) | undefined;
80543
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
80544
+ is_occupied?: (boolean | null) | undefined;
80545
+ /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
80546
+ occupant_count?: (number | null) | undefined;
80547
+ /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
80548
+ is_smoking_detected?: (boolean | null) | undefined;
80549
+ /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
80550
+ named_sensors?: {
80551
+ /** Stable, hardware-defined name of the sensor, such as a port number. */
80552
+ sensor_name: string;
80553
+ /** Display name of the sensor. Defaults to `sensor_name`. */
80554
+ display_name: string;
80555
+ /** Reported temperature in °C. `null` until the first value arrives. */
80556
+ temperature_celsius?: (number | null) | undefined;
80557
+ /** Reported temperature in °F. `null` until the first value arrives. */
80558
+ temperature_fahrenheit?: (number | null) | undefined;
80559
+ /** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
80560
+ relative_humidity?: (number | null) | undefined;
80561
+ /** Noise level in decibels. `null` until the first value arrives. */
80562
+ noise_level_decibels?: (number | null) | undefined;
80563
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
80564
+ noise_level_nrs?: (number | null) | undefined;
80565
+ /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
80566
+ co2_ppm?: (number | null) | undefined;
80567
+ /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
80568
+ co_ppm?: (number | null) | undefined;
80569
+ /** Air quality index, if the device measures it. `null` until the first value arrives. */
80570
+ air_quality_index?: (number | null) | undefined;
80571
+ /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
80572
+ mold_risk_level?: (string | null) | undefined;
80573
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
80574
+ is_occupied?: (boolean | null) | undefined;
80575
+ /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
80576
+ occupant_count?: (number | null) | undefined;
80577
+ /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
80578
+ is_smoking_detected?: (boolean | null) | undefined;
80579
+ }[] | undefined;
80157
80580
  } & {
80158
80581
  /** ASSA ABLOY Credential Service metadata for the phone. */
80159
80582
  assa_abloy_credential_service_metadata?: ({
@@ -80985,11 +81408,11 @@ export type Routes = {
80985
81408
  } | undefined;
80986
81409
  } & {
80987
81410
  /** Reported temperature in °F. */
80988
- temperature_fahrenheit?: number | undefined;
81411
+ temperature_fahrenheit?: (number | null) | undefined;
80989
81412
  /** Reported temperature in °C. */
80990
- temperature_celsius?: number | undefined;
81413
+ temperature_celsius?: (number | null) | undefined;
80991
81414
  /** Reported relative humidity, as a value between 0 and 1, inclusive. */
80992
- relative_humidity?: number | undefined;
81415
+ relative_humidity?: (number | null) | undefined;
80993
81416
  /** HVAC mode settings that the thermostat supports. */
80994
81417
  available_hvac_mode_settings?: ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined;
80995
81418
  /** Fan mode settings that the thermostat supports. */
@@ -81816,9 +82239,56 @@ export type Routes = {
81816
82239
  * @deprecated use offline_access_codes_enabled*/
81817
82240
  supports_offline_access_codes?: boolean | undefined;
81818
82241
  /** Indicates current noise level in decibels, if the device supports noise detection. */
81819
- noise_level_decibels?: number | undefined;
82242
+ noise_level_decibels?: (number | null) | undefined;
81820
82243
  /** Array of noise threshold IDs that are currently triggering. */
81821
82244
  currently_triggering_noise_threshold_ids?: string[] | undefined;
82245
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
82246
+ noise_level_nrs?: (number | null) | undefined;
82247
+ /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
82248
+ co2_ppm?: (number | null) | undefined;
82249
+ /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
82250
+ co_ppm?: (number | null) | undefined;
82251
+ /** Air quality index, if the device measures it. `null` until the first value arrives. */
82252
+ air_quality_index?: (number | null) | undefined;
82253
+ /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
82254
+ mold_risk_level?: (string | null) | undefined;
82255
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
82256
+ is_occupied?: (boolean | null) | undefined;
82257
+ /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
82258
+ occupant_count?: (number | null) | undefined;
82259
+ /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
82260
+ is_smoking_detected?: (boolean | null) | undefined;
82261
+ /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
82262
+ named_sensors?: {
82263
+ /** Stable, hardware-defined name of the sensor, such as a port number. */
82264
+ sensor_name: string;
82265
+ /** Display name of the sensor. Defaults to `sensor_name`. */
82266
+ display_name: string;
82267
+ /** Reported temperature in °C. `null` until the first value arrives. */
82268
+ temperature_celsius?: (number | null) | undefined;
82269
+ /** Reported temperature in °F. `null` until the first value arrives. */
82270
+ temperature_fahrenheit?: (number | null) | undefined;
82271
+ /** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
82272
+ relative_humidity?: (number | null) | undefined;
82273
+ /** Noise level in decibels. `null` until the first value arrives. */
82274
+ noise_level_decibels?: (number | null) | undefined;
82275
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
82276
+ noise_level_nrs?: (number | null) | undefined;
82277
+ /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
82278
+ co2_ppm?: (number | null) | undefined;
82279
+ /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
82280
+ co_ppm?: (number | null) | undefined;
82281
+ /** Air quality index, if the device measures it. `null` until the first value arrives. */
82282
+ air_quality_index?: (number | null) | undefined;
82283
+ /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
82284
+ mold_risk_level?: (string | null) | undefined;
82285
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
82286
+ is_occupied?: (boolean | null) | undefined;
82287
+ /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
82288
+ occupant_count?: (number | null) | undefined;
82289
+ /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
82290
+ is_smoking_detected?: (boolean | null) | undefined;
82291
+ }[] | undefined;
81822
82292
  } & {
81823
82293
  /** ASSA ABLOY Credential Service metadata for the phone. */
81824
82294
  assa_abloy_credential_service_metadata?: ({
@@ -82650,11 +83120,11 @@ export type Routes = {
82650
83120
  } | undefined;
82651
83121
  } & {
82652
83122
  /** Reported temperature in °F. */
82653
- temperature_fahrenheit?: number | undefined;
83123
+ temperature_fahrenheit?: (number | null) | undefined;
82654
83124
  /** Reported temperature in °C. */
82655
- temperature_celsius?: number | undefined;
83125
+ temperature_celsius?: (number | null) | undefined;
82656
83126
  /** Reported relative humidity, as a value between 0 and 1, inclusive. */
82657
- relative_humidity?: number | undefined;
83127
+ relative_humidity?: (number | null) | undefined;
82658
83128
  /** HVAC mode settings that the thermostat supports. */
82659
83129
  available_hvac_mode_settings?: ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined;
82660
83130
  /** Fan mode settings that the thermostat supports. */
@@ -107327,9 +107797,56 @@ export type Routes = {
107327
107797
  * @deprecated use offline_access_codes_enabled*/
107328
107798
  supports_offline_access_codes?: boolean | undefined;
107329
107799
  /** Indicates current noise level in decibels, if the device supports noise detection. */
107330
- noise_level_decibels?: number | undefined;
107800
+ noise_level_decibels?: (number | null) | undefined;
107331
107801
  /** Array of noise threshold IDs that are currently triggering. */
107332
107802
  currently_triggering_noise_threshold_ids?: string[] | undefined;
107803
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
107804
+ noise_level_nrs?: (number | null) | undefined;
107805
+ /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
107806
+ co2_ppm?: (number | null) | undefined;
107807
+ /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
107808
+ co_ppm?: (number | null) | undefined;
107809
+ /** Air quality index, if the device measures it. `null` until the first value arrives. */
107810
+ air_quality_index?: (number | null) | undefined;
107811
+ /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
107812
+ mold_risk_level?: (string | null) | undefined;
107813
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
107814
+ is_occupied?: (boolean | null) | undefined;
107815
+ /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
107816
+ occupant_count?: (number | null) | undefined;
107817
+ /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
107818
+ is_smoking_detected?: (boolean | null) | undefined;
107819
+ /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
107820
+ named_sensors?: {
107821
+ /** Stable, hardware-defined name of the sensor, such as a port number. */
107822
+ sensor_name: string;
107823
+ /** Display name of the sensor. Defaults to `sensor_name`. */
107824
+ display_name: string;
107825
+ /** Reported temperature in °C. `null` until the first value arrives. */
107826
+ temperature_celsius?: (number | null) | undefined;
107827
+ /** Reported temperature in °F. `null` until the first value arrives. */
107828
+ temperature_fahrenheit?: (number | null) | undefined;
107829
+ /** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
107830
+ relative_humidity?: (number | null) | undefined;
107831
+ /** Noise level in decibels. `null` until the first value arrives. */
107832
+ noise_level_decibels?: (number | null) | undefined;
107833
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
107834
+ noise_level_nrs?: (number | null) | undefined;
107835
+ /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
107836
+ co2_ppm?: (number | null) | undefined;
107837
+ /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
107838
+ co_ppm?: (number | null) | undefined;
107839
+ /** Air quality index, if the device measures it. `null` until the first value arrives. */
107840
+ air_quality_index?: (number | null) | undefined;
107841
+ /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
107842
+ mold_risk_level?: (string | null) | undefined;
107843
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
107844
+ is_occupied?: (boolean | null) | undefined;
107845
+ /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
107846
+ occupant_count?: (number | null) | undefined;
107847
+ /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
107848
+ is_smoking_detected?: (boolean | null) | undefined;
107849
+ }[] | undefined;
107333
107850
  } & {
107334
107851
  /** ASSA ABLOY Credential Service metadata for the phone. */
107335
107852
  assa_abloy_credential_service_metadata?: ({
@@ -108161,11 +108678,11 @@ export type Routes = {
108161
108678
  } | undefined;
108162
108679
  } & {
108163
108680
  /** Reported temperature in °F. */
108164
- temperature_fahrenheit?: number | undefined;
108681
+ temperature_fahrenheit?: (number | null) | undefined;
108165
108682
  /** Reported temperature in °C. */
108166
- temperature_celsius?: number | undefined;
108683
+ temperature_celsius?: (number | null) | undefined;
108167
108684
  /** Reported relative humidity, as a value between 0 and 1, inclusive. */
108168
- relative_humidity?: number | undefined;
108685
+ relative_humidity?: (number | null) | undefined;
108169
108686
  /** HVAC mode settings that the thermostat supports. */
108170
108687
  available_hvac_mode_settings?: ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined;
108171
108688
  /** Fan mode settings that the thermostat supports. */
@@ -136558,9 +137075,56 @@ export type Routes = {
136558
137075
  * @deprecated use offline_access_codes_enabled*/
136559
137076
  supports_offline_access_codes?: boolean | undefined;
136560
137077
  /** Indicates current noise level in decibels, if the device supports noise detection. */
136561
- noise_level_decibels?: number | undefined;
137078
+ noise_level_decibels?: (number | null) | undefined;
136562
137079
  /** Array of noise threshold IDs that are currently triggering. */
136563
137080
  currently_triggering_noise_threshold_ids?: string[] | undefined;
137081
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
137082
+ noise_level_nrs?: (number | null) | undefined;
137083
+ /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
137084
+ co2_ppm?: (number | null) | undefined;
137085
+ /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
137086
+ co_ppm?: (number | null) | undefined;
137087
+ /** Air quality index, if the device measures it. `null` until the first value arrives. */
137088
+ air_quality_index?: (number | null) | undefined;
137089
+ /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
137090
+ mold_risk_level?: (string | null) | undefined;
137091
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
137092
+ is_occupied?: (boolean | null) | undefined;
137093
+ /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
137094
+ occupant_count?: (number | null) | undefined;
137095
+ /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
137096
+ is_smoking_detected?: (boolean | null) | undefined;
137097
+ /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
137098
+ named_sensors?: {
137099
+ /** Stable, hardware-defined name of the sensor, such as a port number. */
137100
+ sensor_name: string;
137101
+ /** Display name of the sensor. Defaults to `sensor_name`. */
137102
+ display_name: string;
137103
+ /** Reported temperature in °C. `null` until the first value arrives. */
137104
+ temperature_celsius?: (number | null) | undefined;
137105
+ /** Reported temperature in °F. `null` until the first value arrives. */
137106
+ temperature_fahrenheit?: (number | null) | undefined;
137107
+ /** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
137108
+ relative_humidity?: (number | null) | undefined;
137109
+ /** Noise level in decibels. `null` until the first value arrives. */
137110
+ noise_level_decibels?: (number | null) | undefined;
137111
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
137112
+ noise_level_nrs?: (number | null) | undefined;
137113
+ /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
137114
+ co2_ppm?: (number | null) | undefined;
137115
+ /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
137116
+ co_ppm?: (number | null) | undefined;
137117
+ /** Air quality index, if the device measures it. `null` until the first value arrives. */
137118
+ air_quality_index?: (number | null) | undefined;
137119
+ /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
137120
+ mold_risk_level?: (string | null) | undefined;
137121
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
137122
+ is_occupied?: (boolean | null) | undefined;
137123
+ /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
137124
+ occupant_count?: (number | null) | undefined;
137125
+ /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
137126
+ is_smoking_detected?: (boolean | null) | undefined;
137127
+ }[] | undefined;
136564
137128
  } & {
136565
137129
  /** ASSA ABLOY Credential Service metadata for the phone. */
136566
137130
  assa_abloy_credential_service_metadata?: ({
@@ -137392,11 +137956,11 @@ export type Routes = {
137392
137956
  } | undefined;
137393
137957
  } & {
137394
137958
  /** Reported temperature in °F. */
137395
- temperature_fahrenheit?: number | undefined;
137959
+ temperature_fahrenheit?: (number | null) | undefined;
137396
137960
  /** Reported temperature in °C. */
137397
- temperature_celsius?: number | undefined;
137961
+ temperature_celsius?: (number | null) | undefined;
137398
137962
  /** Reported relative humidity, as a value between 0 and 1, inclusive. */
137399
- relative_humidity?: number | undefined;
137963
+ relative_humidity?: (number | null) | undefined;
137400
137964
  /** HVAC mode settings that the thermostat supports. */
137401
137965
  available_hvac_mode_settings?: ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined;
137402
137966
  /** Fan mode settings that the thermostat supports. */
@@ -142665,9 +143229,56 @@ export type Routes = {
142665
143229
  * @deprecated use offline_access_codes_enabled*/
142666
143230
  supports_offline_access_codes?: boolean | undefined;
142667
143231
  /** Indicates current noise level in decibels, if the device supports noise detection. */
142668
- noise_level_decibels?: number | undefined;
143232
+ noise_level_decibels?: (number | null) | undefined;
142669
143233
  /** Array of noise threshold IDs that are currently triggering. */
142670
143234
  currently_triggering_noise_threshold_ids?: string[] | undefined;
143235
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
143236
+ noise_level_nrs?: (number | null) | undefined;
143237
+ /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
143238
+ co2_ppm?: (number | null) | undefined;
143239
+ /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
143240
+ co_ppm?: (number | null) | undefined;
143241
+ /** Air quality index, if the device measures it. `null` until the first value arrives. */
143242
+ air_quality_index?: (number | null) | undefined;
143243
+ /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
143244
+ mold_risk_level?: (string | null) | undefined;
143245
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
143246
+ is_occupied?: (boolean | null) | undefined;
143247
+ /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
143248
+ occupant_count?: (number | null) | undefined;
143249
+ /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
143250
+ is_smoking_detected?: (boolean | null) | undefined;
143251
+ /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
143252
+ named_sensors?: {
143253
+ /** Stable, hardware-defined name of the sensor, such as a port number. */
143254
+ sensor_name: string;
143255
+ /** Display name of the sensor. Defaults to `sensor_name`. */
143256
+ display_name: string;
143257
+ /** Reported temperature in °C. `null` until the first value arrives. */
143258
+ temperature_celsius?: (number | null) | undefined;
143259
+ /** Reported temperature in °F. `null` until the first value arrives. */
143260
+ temperature_fahrenheit?: (number | null) | undefined;
143261
+ /** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
143262
+ relative_humidity?: (number | null) | undefined;
143263
+ /** Noise level in decibels. `null` until the first value arrives. */
143264
+ noise_level_decibels?: (number | null) | undefined;
143265
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
143266
+ noise_level_nrs?: (number | null) | undefined;
143267
+ /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
143268
+ co2_ppm?: (number | null) | undefined;
143269
+ /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
143270
+ co_ppm?: (number | null) | undefined;
143271
+ /** Air quality index, if the device measures it. `null` until the first value arrives. */
143272
+ air_quality_index?: (number | null) | undefined;
143273
+ /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
143274
+ mold_risk_level?: (string | null) | undefined;
143275
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
143276
+ is_occupied?: (boolean | null) | undefined;
143277
+ /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
143278
+ occupant_count?: (number | null) | undefined;
143279
+ /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
143280
+ is_smoking_detected?: (boolean | null) | undefined;
143281
+ }[] | undefined;
142671
143282
  } & {
142672
143283
  /** ASSA ABLOY Credential Service metadata for the phone. */
142673
143284
  assa_abloy_credential_service_metadata?: ({
@@ -143499,11 +144110,11 @@ export type Routes = {
143499
144110
  } | undefined;
143500
144111
  } & {
143501
144112
  /** Reported temperature in °F. */
143502
- temperature_fahrenheit?: number | undefined;
144113
+ temperature_fahrenheit?: (number | null) | undefined;
143503
144114
  /** Reported temperature in °C. */
143504
- temperature_celsius?: number | undefined;
144115
+ temperature_celsius?: (number | null) | undefined;
143505
144116
  /** Reported relative humidity, as a value between 0 and 1, inclusive. */
143506
- relative_humidity?: number | undefined;
144117
+ relative_humidity?: (number | null) | undefined;
143507
144118
  /** HVAC mode settings that the thermostat supports. */
143508
144119
  available_hvac_mode_settings?: ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined;
143509
144120
  /** Fan mode settings that the thermostat supports. */
@@ -144330,9 +144941,56 @@ export type Routes = {
144330
144941
  * @deprecated use offline_access_codes_enabled*/
144331
144942
  supports_offline_access_codes?: boolean | undefined;
144332
144943
  /** Indicates current noise level in decibels, if the device supports noise detection. */
144333
- noise_level_decibels?: number | undefined;
144944
+ noise_level_decibels?: (number | null) | undefined;
144334
144945
  /** Array of noise threshold IDs that are currently triggering. */
144335
144946
  currently_triggering_noise_threshold_ids?: string[] | undefined;
144947
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
144948
+ noise_level_nrs?: (number | null) | undefined;
144949
+ /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
144950
+ co2_ppm?: (number | null) | undefined;
144951
+ /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
144952
+ co_ppm?: (number | null) | undefined;
144953
+ /** Air quality index, if the device measures it. `null` until the first value arrives. */
144954
+ air_quality_index?: (number | null) | undefined;
144955
+ /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
144956
+ mold_risk_level?: (string | null) | undefined;
144957
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
144958
+ is_occupied?: (boolean | null) | undefined;
144959
+ /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
144960
+ occupant_count?: (number | null) | undefined;
144961
+ /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
144962
+ is_smoking_detected?: (boolean | null) | undefined;
144963
+ /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
144964
+ named_sensors?: {
144965
+ /** Stable, hardware-defined name of the sensor, such as a port number. */
144966
+ sensor_name: string;
144967
+ /** Display name of the sensor. Defaults to `sensor_name`. */
144968
+ display_name: string;
144969
+ /** Reported temperature in °C. `null` until the first value arrives. */
144970
+ temperature_celsius?: (number | null) | undefined;
144971
+ /** Reported temperature in °F. `null` until the first value arrives. */
144972
+ temperature_fahrenheit?: (number | null) | undefined;
144973
+ /** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
144974
+ relative_humidity?: (number | null) | undefined;
144975
+ /** Noise level in decibels. `null` until the first value arrives. */
144976
+ noise_level_decibels?: (number | null) | undefined;
144977
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
144978
+ noise_level_nrs?: (number | null) | undefined;
144979
+ /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
144980
+ co2_ppm?: (number | null) | undefined;
144981
+ /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
144982
+ co_ppm?: (number | null) | undefined;
144983
+ /** Air quality index, if the device measures it. `null` until the first value arrives. */
144984
+ air_quality_index?: (number | null) | undefined;
144985
+ /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
144986
+ mold_risk_level?: (string | null) | undefined;
144987
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
144988
+ is_occupied?: (boolean | null) | undefined;
144989
+ /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
144990
+ occupant_count?: (number | null) | undefined;
144991
+ /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
144992
+ is_smoking_detected?: (boolean | null) | undefined;
144993
+ }[] | undefined;
144336
144994
  } & {
144337
144995
  /** ASSA ABLOY Credential Service metadata for the phone. */
144338
144996
  assa_abloy_credential_service_metadata?: ({
@@ -145164,11 +145822,11 @@ export type Routes = {
145164
145822
  } | undefined;
145165
145823
  } & {
145166
145824
  /** Reported temperature in °F. */
145167
- temperature_fahrenheit?: number | undefined;
145825
+ temperature_fahrenheit?: (number | null) | undefined;
145168
145826
  /** Reported temperature in °C. */
145169
- temperature_celsius?: number | undefined;
145827
+ temperature_celsius?: (number | null) | undefined;
145170
145828
  /** Reported relative humidity, as a value between 0 and 1, inclusive. */
145171
- relative_humidity?: number | undefined;
145829
+ relative_humidity?: (number | null) | undefined;
145172
145830
  /** HVAC mode settings that the thermostat supports. */
145173
145831
  available_hvac_mode_settings?: ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined;
145174
145832
  /** Fan mode settings that the thermostat supports. */
@@ -155940,9 +156598,56 @@ export type Routes = {
155940
156598
  * @deprecated use offline_access_codes_enabled*/
155941
156599
  supports_offline_access_codes?: boolean | undefined;
155942
156600
  /** Indicates current noise level in decibels, if the device supports noise detection. */
155943
- noise_level_decibels?: number | undefined;
156601
+ noise_level_decibels?: (number | null) | undefined;
155944
156602
  /** Array of noise threshold IDs that are currently triggering. */
155945
156603
  currently_triggering_noise_threshold_ids?: string[] | undefined;
156604
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
156605
+ noise_level_nrs?: (number | null) | undefined;
156606
+ /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
156607
+ co2_ppm?: (number | null) | undefined;
156608
+ /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
156609
+ co_ppm?: (number | null) | undefined;
156610
+ /** Air quality index, if the device measures it. `null` until the first value arrives. */
156611
+ air_quality_index?: (number | null) | undefined;
156612
+ /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
156613
+ mold_risk_level?: (string | null) | undefined;
156614
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
156615
+ is_occupied?: (boolean | null) | undefined;
156616
+ /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
156617
+ occupant_count?: (number | null) | undefined;
156618
+ /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
156619
+ is_smoking_detected?: (boolean | null) | undefined;
156620
+ /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
156621
+ named_sensors?: {
156622
+ /** Stable, hardware-defined name of the sensor, such as a port number. */
156623
+ sensor_name: string;
156624
+ /** Display name of the sensor. Defaults to `sensor_name`. */
156625
+ display_name: string;
156626
+ /** Reported temperature in °C. `null` until the first value arrives. */
156627
+ temperature_celsius?: (number | null) | undefined;
156628
+ /** Reported temperature in °F. `null` until the first value arrives. */
156629
+ temperature_fahrenheit?: (number | null) | undefined;
156630
+ /** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
156631
+ relative_humidity?: (number | null) | undefined;
156632
+ /** Noise level in decibels. `null` until the first value arrives. */
156633
+ noise_level_decibels?: (number | null) | undefined;
156634
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
156635
+ noise_level_nrs?: (number | null) | undefined;
156636
+ /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
156637
+ co2_ppm?: (number | null) | undefined;
156638
+ /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
156639
+ co_ppm?: (number | null) | undefined;
156640
+ /** Air quality index, if the device measures it. `null` until the first value arrives. */
156641
+ air_quality_index?: (number | null) | undefined;
156642
+ /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
156643
+ mold_risk_level?: (string | null) | undefined;
156644
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
156645
+ is_occupied?: (boolean | null) | undefined;
156646
+ /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
156647
+ occupant_count?: (number | null) | undefined;
156648
+ /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
156649
+ is_smoking_detected?: (boolean | null) | undefined;
156650
+ }[] | undefined;
155946
156651
  } & {
155947
156652
  /** ASSA ABLOY Credential Service metadata for the phone. */
155948
156653
  assa_abloy_credential_service_metadata?: ({
@@ -156774,11 +157479,11 @@ export type Routes = {
156774
157479
  } | undefined;
156775
157480
  } & {
156776
157481
  /** Reported temperature in °F. */
156777
- temperature_fahrenheit?: number | undefined;
157482
+ temperature_fahrenheit?: (number | null) | undefined;
156778
157483
  /** Reported temperature in °C. */
156779
- temperature_celsius?: number | undefined;
157484
+ temperature_celsius?: (number | null) | undefined;
156780
157485
  /** Reported relative humidity, as a value between 0 and 1, inclusive. */
156781
- relative_humidity?: number | undefined;
157486
+ relative_humidity?: (number | null) | undefined;
156782
157487
  /** HVAC mode settings that the thermostat supports. */
156783
157488
  available_hvac_mode_settings?: ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined;
156784
157489
  /** Fan mode settings that the thermostat supports. */
@@ -157607,9 +158312,56 @@ export type Routes = {
157607
158312
  * @deprecated use offline_access_codes_enabled*/
157608
158313
  supports_offline_access_codes?: boolean | undefined;
157609
158314
  /** Indicates current noise level in decibels, if the device supports noise detection. */
157610
- noise_level_decibels?: number | undefined;
158315
+ noise_level_decibels?: (number | null) | undefined;
157611
158316
  /** Array of noise threshold IDs that are currently triggering. */
157612
158317
  currently_triggering_noise_threshold_ids?: string[] | undefined;
158318
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
158319
+ noise_level_nrs?: (number | null) | undefined;
158320
+ /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
158321
+ co2_ppm?: (number | null) | undefined;
158322
+ /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
158323
+ co_ppm?: (number | null) | undefined;
158324
+ /** Air quality index, if the device measures it. `null` until the first value arrives. */
158325
+ air_quality_index?: (number | null) | undefined;
158326
+ /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
158327
+ mold_risk_level?: (string | null) | undefined;
158328
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
158329
+ is_occupied?: (boolean | null) | undefined;
158330
+ /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
158331
+ occupant_count?: (number | null) | undefined;
158332
+ /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
158333
+ is_smoking_detected?: (boolean | null) | undefined;
158334
+ /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
158335
+ named_sensors?: {
158336
+ /** Stable, hardware-defined name of the sensor, such as a port number. */
158337
+ sensor_name: string;
158338
+ /** Display name of the sensor. Defaults to `sensor_name`. */
158339
+ display_name: string;
158340
+ /** Reported temperature in °C. `null` until the first value arrives. */
158341
+ temperature_celsius?: (number | null) | undefined;
158342
+ /** Reported temperature in °F. `null` until the first value arrives. */
158343
+ temperature_fahrenheit?: (number | null) | undefined;
158344
+ /** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
158345
+ relative_humidity?: (number | null) | undefined;
158346
+ /** Noise level in decibels. `null` until the first value arrives. */
158347
+ noise_level_decibels?: (number | null) | undefined;
158348
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
158349
+ noise_level_nrs?: (number | null) | undefined;
158350
+ /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
158351
+ co2_ppm?: (number | null) | undefined;
158352
+ /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
158353
+ co_ppm?: (number | null) | undefined;
158354
+ /** Air quality index, if the device measures it. `null` until the first value arrives. */
158355
+ air_quality_index?: (number | null) | undefined;
158356
+ /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
158357
+ mold_risk_level?: (string | null) | undefined;
158358
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
158359
+ is_occupied?: (boolean | null) | undefined;
158360
+ /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
158361
+ occupant_count?: (number | null) | undefined;
158362
+ /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
158363
+ is_smoking_detected?: (boolean | null) | undefined;
158364
+ }[] | undefined;
157613
158365
  } & {
157614
158366
  /** ASSA ABLOY Credential Service metadata for the phone. */
157615
158367
  assa_abloy_credential_service_metadata?: ({
@@ -158441,11 +159193,11 @@ export type Routes = {
158441
159193
  } | undefined;
158442
159194
  } & {
158443
159195
  /** Reported temperature in °F. */
158444
- temperature_fahrenheit?: number | undefined;
159196
+ temperature_fahrenheit?: (number | null) | undefined;
158445
159197
  /** Reported temperature in °C. */
158446
- temperature_celsius?: number | undefined;
159198
+ temperature_celsius?: (number | null) | undefined;
158447
159199
  /** Reported relative humidity, as a value between 0 and 1, inclusive. */
158448
- relative_humidity?: number | undefined;
159200
+ relative_humidity?: (number | null) | undefined;
158449
159201
  /** HVAC mode settings that the thermostat supports. */
158450
159202
  available_hvac_mode_settings?: ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined;
158451
159203
  /** Fan mode settings that the thermostat supports. */
@@ -161620,9 +162372,56 @@ export type Routes = {
161620
162372
  * @deprecated use offline_access_codes_enabled*/
161621
162373
  supports_offline_access_codes?: boolean | undefined;
161622
162374
  /** Indicates current noise level in decibels, if the device supports noise detection. */
161623
- noise_level_decibels?: number | undefined;
162375
+ noise_level_decibels?: (number | null) | undefined;
161624
162376
  /** Array of noise threshold IDs that are currently triggering. */
161625
162377
  currently_triggering_noise_threshold_ids?: string[] | undefined;
162378
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
162379
+ noise_level_nrs?: (number | null) | undefined;
162380
+ /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
162381
+ co2_ppm?: (number | null) | undefined;
162382
+ /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
162383
+ co_ppm?: (number | null) | undefined;
162384
+ /** Air quality index, if the device measures it. `null` until the first value arrives. */
162385
+ air_quality_index?: (number | null) | undefined;
162386
+ /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
162387
+ mold_risk_level?: (string | null) | undefined;
162388
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
162389
+ is_occupied?: (boolean | null) | undefined;
162390
+ /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
162391
+ occupant_count?: (number | null) | undefined;
162392
+ /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
162393
+ is_smoking_detected?: (boolean | null) | undefined;
162394
+ /** Additional sensors of the same kind on the device, each with a stable `sensor_name`. Present only when the device has more than one sensor of a kind or no single main sensor. */
162395
+ named_sensors?: {
162396
+ /** Stable, hardware-defined name of the sensor, such as a port number. */
162397
+ sensor_name: string;
162398
+ /** Display name of the sensor. Defaults to `sensor_name`. */
162399
+ display_name: string;
162400
+ /** Reported temperature in °C. `null` until the first value arrives. */
162401
+ temperature_celsius?: (number | null) | undefined;
162402
+ /** Reported temperature in °F. `null` until the first value arrives. */
162403
+ temperature_fahrenheit?: (number | null) | undefined;
162404
+ /** Reported relative humidity, as a value between 0 and 1, inclusive. `null` until the first value arrives. */
162405
+ relative_humidity?: (number | null) | undefined;
162406
+ /** Noise level in decibels. `null` until the first value arrives. */
162407
+ noise_level_decibels?: (number | null) | undefined;
162408
+ /** Noise level as a Noise Risk Score (NRS), if the device reports one. `null` until the first value arrives. */
162409
+ noise_level_nrs?: (number | null) | undefined;
162410
+ /** Carbon dioxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
162411
+ co2_ppm?: (number | null) | undefined;
162412
+ /** Carbon monoxide concentration in parts per million, if the device measures it. `null` until the first value arrives. */
162413
+ co_ppm?: (number | null) | undefined;
162414
+ /** Air quality index, if the device measures it. `null` until the first value arrives. */
162415
+ air_quality_index?: (number | null) | undefined;
162416
+ /** Mold risk level as reported by the device, if the device measures it. `null` until the first value arrives. */
162417
+ mold_risk_level?: (string | null) | undefined;
162418
+ /** Indicates whether the device detects that the space is occupied, if the device measures occupancy. `null` until the first value arrives. */
162419
+ is_occupied?: (boolean | null) | undefined;
162420
+ /** Number of occupants the device detects, if the device counts occupants. `null` until the first value arrives. */
162421
+ occupant_count?: (number | null) | undefined;
162422
+ /** Indicates whether the device detects smoking, if the device measures it. `null` until the first value arrives. */
162423
+ is_smoking_detected?: (boolean | null) | undefined;
162424
+ }[] | undefined;
161626
162425
  } & {
161627
162426
  /** ASSA ABLOY Credential Service metadata for the phone. */
161628
162427
  assa_abloy_credential_service_metadata?: ({
@@ -162454,11 +163253,11 @@ export type Routes = {
162454
163253
  } | undefined;
162455
163254
  } & {
162456
163255
  /** Reported temperature in °F. */
162457
- temperature_fahrenheit?: number | undefined;
163256
+ temperature_fahrenheit?: (number | null) | undefined;
162458
163257
  /** Reported temperature in °C. */
162459
- temperature_celsius?: number | undefined;
163258
+ temperature_celsius?: (number | null) | undefined;
162460
163259
  /** Reported relative humidity, as a value between 0 and 1, inclusive. */
162461
- relative_humidity?: number | undefined;
163260
+ relative_humidity?: (number | null) | undefined;
162462
163261
  /** HVAC mode settings that the thermostat supports. */
162463
163262
  available_hvac_mode_settings?: ('off' | 'heat' | 'cool' | 'heat_cool' | 'eco')[] | undefined;
162464
163263
  /** Fan mode settings that the thermostat supports. */