@rstreamlabs/webtty 1.11.2 → 1.12.2

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
package/README.md CHANGED
@@ -1,6 +1,6 @@
1
1
  # `@rstreamlabs/webtty`
2
2
 
3
- Browser-side client for the rstream WebTTY protocol.
3
+ WebTTY is rstream's remote terminal and command-execution protocol. A server runs on the remote machine and an operator connects through the CLI or a browser. This package implements the browser client so an application can exchange terminal input/output and track process completion.
4
4
 
5
5
  Use this package when you need to connect a web application to a WebTTY server
6
6
  over WebSocket or WebTransport. It handles the protobuf session handshake,
@@ -52,18 +52,6 @@ webtty.connect();
52
52
 
53
53
  ## Interactive Sessions
54
54
 
55
- Connection failures are delivered once through `onError`, including normal
56
- WebTransport closure before the stream opens. Disconnecting also releases a
57
- stream that becomes available after the opening was cancelled. A normal close
58
- after opening still drains buffered output before reporting the session result.
59
-
60
- Error messages redact values from the configured endpoint's query parameters,
61
- userinfo and fragment, including their common URL-encoded forms. Avoid logging
62
- the endpoint separately. An identifiable browser `SecurityError` points to
63
- browser policy and `connect-src`; an empty browser error reports that diagnostic
64
- details are unavailable. Such an error does not establish that CSP is the cause.
65
- Invalid endpoint configuration still throws synchronously without echoing the URL.
66
-
67
55
  For an interactive terminal, write encoded input to stdin and forward terminal
68
56
  resize events.
69
57
 
@@ -82,8 +70,23 @@ webtty.writeStdin(encoder.encode("whoami\n"));
82
70
  webtty.resize(40, 120);
83
71
  ```
84
72
 
85
- Call `closeStdin()` to send EOF, or `disconnect()` to terminate the client
86
- session.
73
+ Call `closeStdin()` to send EOF, or `disconnect()` to release the reader.
74
+ For an Engine-managed detached execution, releasing the reader leaves the
75
+ command running within its original execution budget.
76
+
77
+ ## Connection failures and diagnostics
78
+
79
+ Connection failures are delivered once through `onError`, including normal
80
+ WebTransport closure before the stream opens. Disconnecting also releases a
81
+ stream that becomes available after the opening was cancelled. A normal close
82
+ after opening still drains buffered output before reporting the session result.
83
+
84
+ Error messages redact values from the configured endpoint's query parameters,
85
+ userinfo and fragment, including their common URL-encoded forms. Avoid logging
86
+ the endpoint separately. An identifiable browser `SecurityError` points to
87
+ browser policy and `connect-src`; an empty browser error reports that diagnostic
88
+ details are unavailable. Such an error does not establish that CSP is the cause.
89
+ Invalid endpoint configuration still throws synchronously without echoing the URL.
87
90
 
88
91
  ## Execute Commands
89
92
 
@@ -112,8 +115,34 @@ console.log(result.stdout);
112
115
 
113
116
  Use `openWebTTYCommand` when you need live control over a running command. It
114
117
  returns a command object with replayable stdout/stderr, ordered log iteration,
115
- stdin writes, EOF handling, `wait()`, and `kill()`/`terminate()` session
116
- cleanup.
118
+ stdin writes, EOF handling, `wait()`, and explicit `kill()`/`terminate()`.
119
+
120
+ `terminate({ signal?, timeoutMs? })` sends a protocol termination request and
121
+ waits for the native process result, including final stdout/stderr. `kill()` is
122
+ an alias with the same semantics. The default confirmation wait is 65 seconds.
123
+ `wait()` and `exitCode` retain the native result, including a natural exit that
124
+ races with termination. Repeated requests do not restart termination.
125
+
126
+ Missing native support rejects the operation without disconnecting. An aborted
127
+ or timed-out confirmation wait leaves the remote result unknown and the reader
128
+ connected; `wait()` can still observe a later native result. Use `disconnect()`
129
+ when the application is finished with that reader. No local failure invents an
130
+ exit code. Managed clients must also check the Engine's `explicit_termination`
131
+ capability; an older relay can ignore a request even if a new native server
132
+ advertises support, in which case confirmation times out.
133
+
134
+ Low-level `WebTTY.canTerminate()` exposes native support after `onConnect`.
135
+ `WebTTY.requestTermination()` queues the request; only `onComplete` confirms its
136
+ outcome. Managed control permissions still apply independently of support.
137
+
138
+ Command output capture is bounded to 8 MiB by default (`maxOutputBytes` can set
139
+ another positive byte limit), and at most 32,768 nonempty chunks. Exceeding either
140
+ limit raises `WebTTYCommandOutputLimitError` on output readers and requests
141
+ termination. Further output is discarded while the bounded confirmation wait
142
+ continues; `wait()` still reports a native result if one arrives. If termination
143
+ cannot be confirmed, the command reader is disconnected with an unknown result.
144
+ Use the low-level `WebTTY` output callbacks for continuous streaming without
145
+ retaining a replayable command output buffer.
117
146
 
118
147
  ```ts
119
148
  import { openWebTTYCommand } from "@rstreamlabs/webtty";
@@ -142,20 +171,62 @@ fresh short-lived token. When the WebTTY server is discovered through
142
171
  `@rstreamlabs/tunnels`, pass the advertised `exec_path` value as `execPath`
143
172
  instead of assuming `/`.
144
173
 
174
+ ### Bounded detached execution
175
+
176
+ Fetch WebTTY capabilities from the same Engine that provides the authenticated
177
+ terminal URL, then pass them as `managed.capabilities`. The object returned by
178
+ `@rstreamlabs/tunnels`' WebTTY capabilities API is directly compatible.
179
+
180
+ ```ts
181
+ const command = openWebTTYCommand(
182
+ {
183
+ url: authenticatedTerminalUrl,
184
+ managed: { capabilities, executionSeconds: 300 },
185
+ },
186
+ { cmdArgs: ["sh", "-c", "run-job"], interactive: false, allocateTty: false },
187
+ );
188
+ await command.ready();
189
+ const executionId = command.managedSessionId;
190
+ // Save executionId before releasing the reader.
191
+ command.disconnect();
192
+ ```
193
+
194
+ The SDK checks the advertised transport and maximum duration before connecting.
195
+ `ready()` waits for the relay's confirmation; `managedSessionId` then identifies
196
+ the same execution for later session API calls. `ready({ signal })` cancels only
197
+ that wait. A missing or zero budget preserves the ordinary connection-bound
198
+ lifetime. Detaching does not establish an exit result, and losing the opening
199
+ response does not make retrying the command safe.
200
+
201
+ Use the saved ID to inspect the session or obtain an authorized participant and
202
+ Attach grant. No new Open is needed to recover a running command. The original
203
+ deadline remains unchanged. This does not add restart survival or an output
204
+ cursor; historical output still depends on recording and retention permissions.
205
+
206
+ For any managed connection, including Attach, `managed.capabilities` also gates
207
+ explicit termination: both Engine and native server support are required. An
208
+ Attach without this capability snapshot cannot send Terminate. Current control
209
+ authority is still checked by the Engine for every request.
210
+
211
+ Omitting `executionSeconds` or setting it to zero keeps the ordinary connection
212
+ lifetime, including when the Engine reports `managed_protocol: false`. Supplying
213
+ that capability snapshot still prevents unsupported termination requests.
214
+
145
215
  ### Managed session attach
146
216
 
147
217
  Engine-managed sessions are joined with a WebTTY `Attach` message. The attach
148
218
  grant is obtained from the control-plane API, then sent as the first protobuf
149
219
  message on the terminal stream. Terminal input and output stay on the WebTTY
150
- data path. The current engine live participant stream accepts WebSocket-backed
151
- sessions only; WebTransport attach encoding is available in the protocol/SDK,
152
- but engines that do not expose a WebTransport participant stream reject those
153
- sessions before issuing an attach grant.
220
+ data path. The Engine participant stream uses WebSocket, including when the
221
+ original execution used WebTransport. Check the session's `live.attachable`
222
+ state before requesting an Attach grant and use its advertised participant
223
+ transport.
154
224
 
155
225
  ```ts
156
226
  import { WebTTY } from "@rstreamlabs/webtty";
157
227
 
158
228
  const session = new WebTTY({
229
+ managed: { capabilities },
159
230
  attach: {
160
231
  attachGrant,
161
232
  capabilities: ["read_stream", "request_control"],
@@ -223,7 +294,7 @@ const files = await fs.list("/");
223
294
  const compose = await fs.readText("/compose.yaml");
224
295
  const stream = await fs.readStream("/large.log");
225
296
 
226
- await fs.writeFile("/notes/codex.txt", "checked by Codex\n");
297
+ await fs.writeFile("/notes/status.txt", "Ready\n");
227
298
  ```
228
299
 
229
300
  When the WebTTY server is discovered through `@rstreamlabs/tunnels`, pass the
@@ -296,12 +367,10 @@ const result = await runWebTTYCommand(
296
367
  This uses HTTP/1.1 WebSocket with normal TLS verification, a 10-second handshake
297
368
  deadline, a 1-second close deadline and the configured `maxMessageSize` limit.
298
369
  It works independently of the global WebSocket implementation and does not
299
- modify other clients or browser bundles. The same option applies to `WebTTY`,
300
- `openWebTTYCommand` and `WebTTYRemoteExecutor`. WebTransport still requires a
301
- runtime that provides it; selecting it never falls back silently to WebSocket.
302
- Node 26.7's experimental HTTP/2 WebSocket handshake rejects a conforming
303
- [RFC 8441 endpoint](https://www.rfc-editor.org/rfc/rfc8441.html#section-5);
304
- the Node factory avoids that runtime-specific failure.
370
+ modify other clients or browser bundles. The same option is accepted by
371
+ `WebTTY`, `runWebTTYCommand`, `openWebTTYCommand` and `WebTTYRemoteExecutor`.
372
+ Choose WebTransport explicitly when the runtime and endpoint support it;
373
+ transport selection preserves the requested protocol.
305
374
 
306
375
  Use WebTransport when the endpoint is published over HTTP/3 WebTransport:
307
376
 
@@ -488,6 +557,9 @@ Browser WebTTY sessions should use short-lived tokens scoped to the specific
488
557
  tunnel and path. Do not embed personal access tokens or application credentials
489
558
  in frontend code.
490
559
 
560
+ The [Node transport dependency baseline](docs/000-dependencies.md) explains the
561
+ qualified `ws` version and bounded automatic Pong behavior.
562
+
491
563
  ## Development
492
564
 
493
565
  ```sh