@portll/cobolwork 0.3.0 → 0.4.0

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
package/lib/words.mjs CHANGED
@@ -10,23 +10,383 @@
10
10
  // licensed on the project's own terms rather than on another project's. See LICENSING.md.
11
11
  //
12
12
  // Attested by, retrieved 2026-09-24:
13
- // ACUCOBOL-GT Appendices v9.0.1, Appendix B "ACUCOBOL-GT Reserved Words" and Appendix F "Intrinsic Functions"; ACUCOBOL-GT Reference Manual v8.1.3; Appendices, ACUCOBOL-GT v8.1.3; RM/COBOL Language Reference Manual, Second Edition (Version 12, Liant Software), Appendix A "Reserved Words"; RM/COBOL Language Reference Manual Version 8.0 - ACUCOBOL-GT Appendices v9.0.1, Appendix B.2 Reserved Word List (primary source for ACUCOBOL words); ACUCOBOL-GT Appendices v9.0.1, Appendix B.1 Conventions (the dialect-marker legend); ACUCOBOL-GT Appendices v9.0.1, Appendix F.2.1 Function Definitions (intrinsic function table); ACUCOBOL-GT Appendices v9.0.1 WebWorks page manifest; its section titles "F.n <NAME> Function" independently name every intrinsic function; ACUCOBOL-GT User's Guide v9.0.1 section 2.2.9 Reserved Word Options (-R2/-R8/-Ra/-Ri/-Rr/-Rs/-Rv: the compiler switches that correspond to the appendix markers); Appendices, ACUCOBOL-GT v8.1.3 (Micro Focus) - Appendix B Reserved Words and Appendix F Intrinsic Functions; second, independent extraction of the same two lists; Reference Manual, ACUCOBOL-GT v8.1.3 (Micro Focus) - special registers, SPECIAL-NAMES system-names, ACCEPT FROM DATE YYYYMMDD syntax; RM/COBOL Language Reference Manual, Second Edition (Version 12, Liant Software, copyright 1985-2008, as served by supportline.microfocus.com) - Appendix A Reserved Words, Table 37 Context-Sensitive Words, Tables 38-42 Nonreserved System-Names, and Chapter 1 Special Registers; RM/COBOL Language Reference Manual Version 8.0 (Liant Software) - Appendix A Reserved Words; cross-check of the v12 list
14
- // CICS Transaction Server for z/OS Version 5 Release 3, Application Programming Reference (SC34-7402-00), Appendix H 'BMS-related constants' - Appendix H, BMS-related constants: Table 24 (DFHBMSCA) and Table 1 (DFHAID)
15
- // Fujitsu BS2000 COBOL2000 V1.6 COBOL Compiler Reference Manual; Fujitsu BS2000 COBOL85 V2.3A Reference Manual (U3979-J-Z125-6-7600); FUJITSU Software NetCOBOL V11.0 Language Reference (B1WD-3304-02ENZ0(00), October 2014); Bull DPS7000/XTA NOVASCALE 7000 GCOS 7 COBOL85 Reference Manual (47 A2 05UL 04, November 1997) - COBOL2000 V1.6 Reference Manual, "COBOL words": reserved words, compiler-directive words, context-sensitive words, special registers (English); COBOL2000 V1.6 Sprachbeschreibung, "COBOL-Woerter" (German edition; fetched only to confirm the reserved words are the English COBOL words); COBOL2000 V1.6 Reference Manual, "Overview of intrinsic functions" (English); COBOL2000 V1.6 COBOL Compiler Reference Manual, full PDF (English): corroborates the HTML parse; implementor-name Table 8; ASSIGN device names; BS2000 COBOL85 V2.3A Reference Manual, U3979-J-Z125-6-7600 (English): reserved words table, special registers Table 2-5, implementor-names Table 3-1; FUJITSU Software NetCOBOL V11.0 Language Reference, B1WD-3304-02ENZ0(00), October 2014 (English): Appendix A List of Reserved Words, intrinsic functions, special registers, SPECIAL-NAMES function-names; Bull DPS7000/XTA NOVASCALE 7000 GCOS 7 COBOL85 Reference Manual, 47 A2 05UL 04, November 1997 (English): Appendix A COBOL Reserved Words, special registers
16
- // User Interface Programming, ACUCOBOL-GT Version 8.1.3 (Micro Focus, E-01-UI-100501-ACUCOBOL-GT-8.1.3); Reference Manual, ACUCOBOL-GT Version 8.1.3 (Micro Focus); Appendices, ACUCOBOL-GT Version 8.1.3 (Micro Focus); ACUCOBOL-GT User's Guide Version 9.0.1 section 2.2.9 and Appendices Version 9.0.1 Appendix B.2; RM/COBOL Language Reference Manual, Second Edition (Version 12, Liant Software), Appendix A Table 37; RM/COBOL Language Reference Manual Version 8.0 (Liant Software), Appendix A Table A-1 - User Interface Programming, ACUCOBOL-GT 8.1.3 (form E-01-UI-100501-ACUCOBOL-GT-8.1.3). Primary source for this pass: 3.2 Control Types, Handles, and IDs; 4.4 Styles and Special Properties; Chapter 5 Control Types Reference, whose per-control 5.n.1 Common Properties / STYLES and 5.n.2 Special Properties lists define every style and special property; 5.2 Global Styles; Chapter 6 Events Reference; and the manual index, which repeats each property as '<WORD>, <CONTROL-TYPE> style|special property <page>'; Reference Manual, ACUCOBOL-GT 8.1.3. Used for 5.8 Screen Section general format (5-92..5-94), 6.4.9 Common Screen Options (EVENT-LIST / AX-EVENT-LIST / EXCLUDE-EVENT-LIST at 6-34, MAX-HEIGHT / MAX-WIDTH / MIN-HEIGHT / MIN-WIDTH at 6-43), 6.6 DISPLAY Formats 11 and 12 (window phrases MIN-SIZE, MAX-SIZE, MIN-LINES, MAX-LINES, NO-CLOSE at 6-186..6-196), and the ACCEPT ... FROM STANDARD OBJECT 'Object-Name / Resource' table at 6-92..6-93; Appendices, ACUCOBOL-GT 8.1.3. Appendix B Reserved Words (the list these words are missing from, and the source of the alphabet-heading letters), Appendix H Configuration Variables and Appendix I Library Routines (where STDIN, TIMESTAMP, WINAPI, XOR, STDOUT, STDERR turn out to live); ACUCOBOL-GT User's Guide 9.0.1, 2.2.9 Reserved Word Options. The -Rw entry is the vendor's own statement that control names and property names are NOT reserved words: 'This option also allows you to suppress some non-reserved words, such as control names (e.g., "entry-field", "label") or property names (e.g., "max-text", "bitmap-number").'; ACUCOBOL-GT Appendices 9.0.1, Appendix B.2 Reserved Word List. Re-parsed here only as a negative control: 629 tokens harvested, and not one of the 86 words attested below appears in it; RM/COBOL Language Reference Manual, Second Edition (Version 12, Liant Software, copyright 1985-2008, as served by supportline.microfocus.com), Appendix A, Table 37 'Context-Sensitive Words' - the table that attests BACKGROUND, CASE-INSENSITIVE, END-COPY, END-REPLACE, FOREGROUND, TRIMMED, WHILE; RM/COBOL Language Reference Manual Version 8.0 (Liant Software). Appendix A, Table A-1 'Context-Sensitive Words', which carries BACKGROUND, CASE-INSENSITIVE, FOREGROUND and TRIMMED but not END-COPY, END-REPLACE or WHILE
17
- // Adjudication of the 21 residue words against the first pass's 230-file corpus plus newly searched vendor documentation. Documents relied on: ACUCOBOL-GT 8.1.3 User Interface Programming, 8.1.3 Reference Manual, 8.1.3 Appendices and 9.0.1 Appendices Appendix B.2 Reserved Word List; Heirloom Computing Elastic COBOL Language Reference Manual Appendix (August 2012); Micro Focus Visual COBOL 9.0 Reserved Words Table and Context-sensitive Words Table; IBM Enterprise COBOL for z/OS 6.4 'Reserved words'; IBM COBOL for VSE/ESA Language Reference SC26-8073-02 Table 48; Veryant isCOBOL Evolve 2021R2 Appendix D 'Intrinsic Functions' and isCOBOL Evolve 2023 R1 Overview; RM/COBOL Language Reference Manual, Second Edition (Version 12, Liant Software); Unisys COBOL ANSI-85 Programming Reference Manual Vol.1 (86001518-307); ISO/IEC 1989:20xx CD 1.2 (2009-08-23); COBOL Consortium (Japan) summary of ISO/IEC 1989:2023 - ACUCOBOL-GT 8.1.3 User Interface Programming, ch.5 FRAME 'special properties': the LOW-COLOR property definition entry at 5-70 and the index entry 'LOW-COLOR, FRAME special property 5-70'; Heirloom Computing, Elastic COBOL Language Reference Manual Appendix (rev. August 2012): FRAME 'Properties Table' p.69 with columns Name/MODIFY/INQUIRE/Descriptions, the BAR 'Properties Table', and the copybook constants list (FP-*, BRS-*); Micro Focus Visual COBOL 9.0, Context-sensitive Words Table: the full GUI property-word set including every BITMAP-prefixed word, TRANSPARENT-COLOR, DOT-DASH and NO-TAB; Micro Focus Visual COBOL 9.0, Reserved Words Table: METACLASS, UNEQUAL, and the BINARY-CHAR/-SHORT/-LONG/-DOUBLE usage set; IBM Enterprise COBOL for z/OS 6.4, appendix 'Reserved words': EGCS, and the BINARY-CHAR/-SHORT/-LONG/-DOUBLE usage set; IBM COBOL for VSE/ESA Language Reference, SC26-8073-02, Table 48 'Reserved Words' p.454: the sequence AREA, AREA-VALUE, AREAS; ACUCOBOL-GT 9.0.1 Appendices, Appendix B.2 Reserved Word List: 624 distinct words, containing no GUI property names at all; ACUCOBOL-GT 8.1.3 Reference Manual, Procedure Division relation-condition general format '{ IS UNEQUAL TO obj-item }' at 6-222; Veryant isCOBOL Evolve 2021R2, Appendix D 'Intrinsic Functions': the complete table of all 66 intrinsic functions isCOBOL provides; Veryant isCOBOL Evolve 2023 R1 Overview: the only literal 'Content-Length' in the entire corpus, an HTTP response header inside a logged SOAP trace; RM/COBOL Language Reference Manual, Second Edition (Version 12, Liant Software, copyright 1985-2008, as served by supportline.microfocus.com): ACCEPT/FULL prose using the phrase 'field terminator'; ACUCOBOL-GT 8.1.3 Appendices: the line-drawing figure enumeration whose item 10 reads 'missing right line'; Unisys COBOL ANSI-85 Programming Reference Manual Vol.1 (86001518-307): VREADTIMER prose 'the ACCEPT statement with the TIMER option for the microsecond timer'; COBOL Consortium (Japan), overview of the new features of the 2023 edition of the COBOL international standard; the only new word-like items it names are SHIFT-L, SHIFT-LC, SHIFT-R, SHIFT-RC; ISO/IEC 1989:20xx CD 1.2 dated 2009-08-23, full 910-page text (zip member STD.BK.pdf), searched for every candidate intrinsic-function name in this scope
18
- // Bull DPS7000/XTA GCOS 7 COBOL 85 Reference Manual (47 A2 05UL Rev04, November 1997); FUJITSU Software NetCOBOL V11.0 Language Reference (B1WD-3304-02ENZ0(00), October 2014); Fujitsu BS2000 COBOL85 V2.3A Reference Manual (U3979-J-Z125-6-7600) and BS2000 COBOL2000 V1.6 COBOL Compiler Reference Manual; IBM Enterprise COBOL for z/OS V6.4 Language Reference (SC27-8713-03) with its IBM Docs 'SPECIAL-NAMES paragraph' and 'Reserved words' topics; HP COBOL II/XL Reference Manual (HP 3000 / MPE iX, doc id B3150090013); Heirloom Computing Elastic COBOL Language Reference Manual; Unisys COBOL ANSI-85 Programming Reference Manual Volume 1 (8600 1518-307, February 2003); HP COBOL Manual for TNS and TNS/R Programs (522555-006); ACUCOBOL-GT Reference Manual and Appendices v8.1.3; Micro Focus Visual COBOL 6.0 COBOL Language Reference, 'Switch-Names'; COBOL Consortium of Japan, '2023 nen-ban COBOL kokusai kikaku no shin-kinou no gaiyou'; INCITS, 'Available Now - 2023 Edition of ISO/IEC 1989, COBOL' - Bull DPS7000/XTA GCOS 7 COBOL 85 Reference Manual, 47 A2 05UL Rev04 (Nov 1997): Appendix A 'COBOL Reserved Words' (pp. A-1..A-16 = PDF pp. 611-626), chapter 3 'System-Names', Appendix C 'The ANSI Flagger'; FUJITSU Software NetCOBOL V11.0 Language Reference, B1WD-3304-02ENZ0(00) (Oct 2014): 6.2 'Procedure Division Header' Format (p.238), 6.4.6 CALL statement Formats 1 and 2 (pp.277-279), Appendix A 'List of Reserved Words' (pp.684-704), SPECIAL-NAMES function-name-2 SWITCH-n rule (p.92); Fujitsu BS2000 COBOL85 V2.3A Reference Manual, U3979-J-Z125-6-7600: glossary entry 'Implementor-name' (p.21), Table 3-1 'Implementor-names and their meanings' (p.126), reserved-words list row 'USW-1...USW-31' (p.58); Fujitsu BS2000 COBOL2000 V1.6 COBOL Compiler Reference Manual: glossary entry 'Implementor-name', Table 8 'Implementor-names and their meanings' (6.2.3.1, pp.199-200); IBM Enterprise COBOL for z/OS V6.4 Language Reference, SC27-8713-03: OCCURS clause 'Format 2: variable-length tables' and the UNBOUNDED syntax-element description (p.203); ALLOCATE statement Format and 'LOC phrase' (pp.313-315); XML GENERATE statement Format, 'XML-DECLARATION phrase' and 'NAMESPACE and NAMESPACE-PREFIX phrases' (p.483ff); XML PARSE statement Format and 'VALIDATING phrase'; IBM Enterprise COBOL for z/OS 6.4, 'SPECIAL-NAMES paragraph': the environment-name-2 entry that states the UPSI range; IBM Enterprise COBOL for z/OS 6.4, appendix 'Reserved words' (one table; columns Word / Reserved / Standard only / Potential reserved words; 515 word rows) - the negative check for the IBM candidates; COBOL Consortium of Japan (COBOL ), '2023 COBOL ' by Wataru Takagi (Hitachi), 2024-10-08, updated 2025-05-16: item (3) names the four boolean shift operators added by ISO/IEC 1989:2023; INCITS, 'Available Now - 2023 Edition of ISO/IEC 1989, COBOL': reproduces the ISO/IEC 1989:2023 foreword 'main changes' list, which includes '- Boolean shifting operators' (corroborates the feature; does not name the words); Reference Manual, ACUCOBOL-GT v8.1.3: SPECIAL-NAMES paragraph, Syntax Rule 1 - the ACUCOBOL switch-name range (pp.4-6/4-7); Appendices, ACUCOBOL-GT v8.1.3: Appendix D 'List of Errors', messages 'Invalid switch number', 'Missing switch number' and 'Unknown switch' - each restates the SWITCH-1..SWITCH-26 range; Heirloom Computing, Elastic COBOL Language Reference Manual: SWITCH clause general rule 4, 'Certain aliases exist for the switches for compatibility with more platforms', and its Name/Synonyms table (PDF pp.144-145), which names UPSI-0 through UPSI-9; Unisys COBOL ANSI-85 Programming Reference Manual Volume 1, 8600 1518-307 (Feb 2003): SPECIAL-NAMES switch-name clause - the Unisys SW1..SW8 range; HP COBOL Manual for TNS and TNS/R Programs, 522555-006: 'System-Name Clause With a STATUS Phrase' - the HP NonStop SWITCH-1..SWITCH-15 range; HP COBOL II/XL Reference Manual (HP 3000, MPE/iX 5.0 documentation, doc id B3150090013; 3kranger.com HTTrack mirror of docs.hp.com), 'SPECIAL-NAMES Paragraph': Table 6-1 'HP COBOL II Feature, Switch, and Device Names' with the Switch Name row 'SW0 through SW15', and the 'Software Switches' subsection; HP COBOL II/XL Reference Manual, Appendix F 'COBOL Reserved Word List', Table F-1 - negative check: the SWn switch-names are not in it; Micro Focus Visual COBOL 6.0 COBOL Language Reference, 'Switch-Names' (Environment Division) - the Micro Focus switch numbering
19
- // ISO/IEC 1989, Information technology - Programming languages, their environments and system software interfaces - Programming language COBOL. Re-derived from the three full draft texts reachable without a paywall: (1) ISO/IEC FCD 1989:2001 (E), Final Committee Draft, working document ISO/IEC/JTC 1/SC 22/WG 4 N 0147, 2001-01-15, 891 pp, circulated by the SC 22 secretariat as SC 22 N 3204 - the draft of the edition published as ISO/IEC 1989:2002; (2) ISO/IEC 1989:20xx CD 1.2 (E), Committee Draft International Standard, 2009-08-23, 910 pp, distributed as std.zip by INCITS PL22.4 (formerly J4); and (3) ISO/IEC 1989:20xx FCD 1.0 (E), Final Committee Draft International Standard, 2010-07-13, 901 pp, circulated as SC 22 N 4561 'Text for FCD ballot or comment' - the latest full text on the track to ISO/IEC 1989:2014, fetched by this pass. Clause numbering of the published editions was confirmed against the official Contents-only previews of ISO/IEC FDIS 1989:2013, ISO/IEC 1989:2014 and ISO/IEC 1989:2023. - ISO/IEC FCD 1989:2001 (E) (WG4 N 0147), 891 pp: 8.9 Reserved words p.140, 8.10 Context-sensitive words p.143, 8.12 Compiler-directive reserved words p.146, 8.2 Locales p.59 and 8.2.1 Locale field names p.60, 14.7.11.2.5 Exception-names and exception conditions with Table 13 pp.401-405; ISO/IEC 1989:20xx CD 1.2 (E), 2009-08-23, 910 pp: 8.9 Reserved words p.154, 8.10 Context-sensitive words p.157, 8.12 Compiler-directive words p.161, 7.3.20 TURN directive p.58, 8.2 Locales p.65 and 8.2.1 Locale field names p.66, 14.6.12.1.5 Exception-names and exception conditions with Table 14 pp.422-427, 14.6.12.2 Incompatible data p.427; NEW THIS PASS. SC 22 N 4561, 'Text for FCD ballot or comment', dated 2010-08-06, carrying the full ISO/IEC 1989:20xx FCD 1.0 (E) of 2010-07-13, 901 pp - the latest full draft text of the 2014 edition that is publicly reachable: 8.9 Reserved words p.156, 8.10 Context-sensitive words p.159, 8.12 Compiler-directive words p.163, 14.6.12.1.5 Exception-names and exception conditions with Table 14 p.426; ISO/IEC 1989:2014 official preview, cover plus Contents to p.xv: 8.9 Reserved words p.167, 8.10 Context-sensitive words p.170, 8.12 Compiler-directive words p.174, 11.9.7 FLOAT-BINARY clause and 11.9.8 FLOAT-DECIMAL clause p.220. No word lists; ISO/IEC FDIS 1989:2013 (E) official preview, voting 2013-09-18 to 2013-11-18, served under the 2014 catalogue entry 51416; URL re-verified by sha256 this pass. Contents only, carrying 11.9.7 FLOAT-BINARY clause and 11.9.8 FLOAT-DECIMAL clause. No word lists; ISO/IEC 1989:2023 official preview, cover plus Contents to p.xv: 8.5.2.9 Message-tag category p.164, 8.9 Reserved words p.205, 8.10 Context-sensitive words p.209, 11.9.8 FLOAT-BINARY clause and 11.9.9 FLOAT-DECIMAL clause p.275. No word lists; INCITS PL22.4 (J4) 08-0116 (S-16), 'Candidate features for a future revision'. Cited only for the negative finding on EXCLUSIVE-OR; Archived INCITS PL22.4 (J4) document index, 2016 snapshot. Cited only for the negative findings on FLOAT-DECIMAL-7 and ENGRAVED. The first pass did not record the exact Wayback timestamp and web.archive.org answered 'Temporarily Offline' during this pass, so the URL is given in the date-prefix form; RM/COBOL Language Reference Manual, Second Edition (Version 12, Liant Software, copyright 1985-2008, as served by supportline.microfocus.com). Cited only for the negative finding on CURRENCY-SYMBOL, which occurs there solely inside the RUN-ATTR configuration keyword EDIT-CURRENCY-SYMBOL
20
- // Micro Focus Visual COBOL 9.0 COBOL Language Reference, appendix "Context-sensitive Words Table" (topic id HRLHLHARES04), with the same manual's "Reserved Words Table" (HRLHLHARES01U005) and "Special registers" (HRLHLHCLANU020); Micro Focus Net Express 3.1 Language Reference (Appendix D "Reserved Words", lrares.htm, and Chapter 2 "COBOL Language", lrclan.htm); and Micro Focus Server Express 6.0 Language Reference, "reuze" doc set (lhclan.htm). Micro Focus publishes these HTML topic sets without form numbers; the topic ids above are the documents' own DC.Identifier values. - Appendix: Context-sensitive Words Table (DC.Identifier HRLHLHARES04) - the table that attests all 181 words; Appendix: Reserved Words Table, with the dialect-code legend - checked as negative evidence: none of the 13 hunted registers, and none of the 181, is a row of it; Special registers, Table 1 (Visual COBOL 9.0) - read in full; ADDRESS OF, CURRENT-DATE, DEBUG-ITEM, JSON-CODE, JSON-STATUS, LENGTH OF, LINAGE-COUNTER, RETURN-CODE, SHIFT-IN, SHIFT-OUT, SORT-*, TALLY, TIME-OF-DAY, WHEN-COMPILED, XML-* only; Net Express 3.1 Language Reference, Appendix D: Reserved Words - the file cited for 7 words; the string is an unrendered HTML comment at the head of D.3 and is NOT used as attestation; Net Express 3.1 Language Reference, Chapter 2 COBOL Language - 2.2.4.6 Special Registers (12-row table) and 2.2.4.7 Predefined Object Identifiers; fetched by this pass as negative evidence for the 13; Server Express 6.0 ('reuze') Language Reference, COBOL Language chapter - Table 2: Special Registers (22 rows); fetched live by this pass as negative evidence for the 13
21
- // GnuCOBOL Programmer’s Guide, for GnuCOBOL 3.2 (15 January 2023 build), Gary L. Cutler and Vincent B. Coen - 8.1.11 CONCAT and CONCATENATE, 8.1.58 MODULE-CALLER-ID, 8.1.61 MODULE-ID, 8.1.63 MODULE-SOURCE (Intrinsic Functions); 7.7 Special Registers (NUMBER-OF-CALL-PARAMETERS); 7.8.1.5 ACCEPT FROM DATE/TIME (MICROSECOND-TIME); 7.7 Special Registers and Appendix C1 Internal registers (COB-CRT-STATUS); 8.1.59, 8.1.60, 8.1.62, 8.1.64 and Appendix C2 Intrinsic Functions (MODULE-DATE, MODULE-FORMATTED-DATE, MODULE-PATH, MODULE-TIME); 8.1.88, 8.1.89 and Appendix C2 (SUBSTITUTE, SUBSTITUTE-CASE); 5.1.3 SPECIAL-NAMES rule 14 and Appendix C4 System names: device (STDIN, STDOUT, STDERR); Appendix C1 Common reserved words (B-SHIFT-L, B-SHIFT-R, B-SHIFT-LC, B-SHIFT-RC, NOTHING, NONNUMERIC, NESTED, FLOAT-INFINITY, PHYSICAL, ACTIVATING, TOP-LEVEL, CURRENT, STACK, ANUM, HEX, NAT, FLOAT-NOT-A-NUMBER, PASCAL, STDCALL); An earlier build of the same guide, which attests five of the seven; CONCAT and MICROSECOND-TIME postdate it
22
- // IBM Enterprise COBOL for z/OS, V6.4 Language Reference (SC27-8713-03, seventh edition, 28 April 2026 update) - Special registers; Intrinsic functions; Function definitions (Table of functions); SPECIAL-NAMES paragraph (Meanings of environment names); WRITE for sequential files (channel environment-names); DEBUG-ITEM special register; Enterprise COBOL for z/OS 6.4 Language Reference, complete PDF (SC27-8713-03); Text rendering of the PDF, used for cross-checking only
23
- // IBM Enterprise COBOL for z/OS, Version 6.4, Language Reference -- appendix "Reserved words" (form number SC27-8713-03, not attested in the fetched bytes) - Reserved words
24
- // IBM COBOL for AIX 5.1 Language Reference (SC27-5403-00) and its IBM Docs "Reserved words" appendix; IBM COBOL for Linux on x86 1.1/1.2 Language reference (SC28-3117-01) and its "Reserved words" appendix; IBM COBOL for VSE/ESA Language Reference Release 1 (SC26-8073-02) Appendix D; Enterprise COBOL for z/OS Compiler and Runtime Migration Guide V3R4 (GC27-1409-04) Appendix B and Enterprise COBOL for z/OS 6.4 Migration Guide (GC27-8715-03) Appendix B, whose reserved-word comparison tables attest IBM COBOL, VS COBOL II and OS/VS COBOL; IBM VS COBOL for OS/VS Release 2.4 (GC26-3857-3) - IBM COBOL for AIX 5.1 - Appendix "Reserved words" (Table 1), raw HTML table, 512 word rows; IBM COBOL for Linux on x86 1.1 - Appendix "Reserved words" (Table 1), 515 word rows; IBM COBOL for Linux on x86 1.2 - Appendix "Reserved words" (Table 1), 515 word rows; COBOL for AIX Language Reference V5.1, SC27-5403-00 - "Special registers" (p.16-48), "Function-names"/Table 58 table of functions and Chapter 22 function sections, Table 6 "Meanings of environment names" (p.114), Appendix F "Reserved words" (Table 66); IBM COBOL for Linux on x86 1.2 Language reference, SC28-3117-01 - "Special registers", Part 7 intrinsic-function chapters, Table 5 "Meanings of environment names" (p.98), "Reserved words" appendix; Enterprise COBOL for z/OS Compiler and Runtime Migration Guide V3R4, GC27-1409-04 - Appendix B "COBOL reserved word comparison", Table 46 (PDF pages 266-283 = book pages 245-262): one row per word, columns Enterprise COBOL / IBM COBOL / VS COBOL II / OS/VS COBOL; Enterprise COBOL for z/OS 6.4 Migration Guide, GC27-8715-03 - Appendix B "COBOL reserved word comparison", Table 55 (PDF pages 328-350), same four columns; used as the second edition of the same table and to adjudicate two disagreements with GC27-1409-04; IBM COBOL for VSE/ESA Language Reference Release 1, SC26-8073-02 - Appendix D "Reserved Words", Table 48 (7 pages, two column-groups per page: COBOL/VSE | Standard Only | RFD); also "Special Registers" (p.8ff) and Table 4 "Meanings of Environment Names"; IBM VS COBOL for OS/VS Release 2.4, GC26-3857-3 (the OS/VS COBOL language manual; scanned IBM publication with an OCR text layer, mirrored by bitsavers) - "Reserved words" (book p.15, the six types incl. special registers), APPLY CORE-INDEX format (book p.369), special register LABEL-RETURN (book p.375), FIPS-flagging lists of special registers (book p.343/348), Appendix F "OS/VS COBOL Reserved Word List". Used for adjudication and for two words only, never as a bulk source, because OCR corrupts digits (SKIP1 -> "SKIPI", C01 -> "COl", UPSI-0 -> "UPSI-O")
25
- // IBM interface-block field definitions: CICS TS 6.x 'EIB fields including EIBRESP and EIBRESP2' and Data Areas 'EIB - EXEC interface block' (DFHEIBLK); IMS 15.4 Application Programming 'Specifying the DL/I interface block (DIB)'; Db2 13 for z/OS SQL Reference 'The included SQLCA', 'Description of SQLCA fields', 'The included SQLDA' and 'SQLDA field descriptions' - CICS TS 6.x: EIB fields including EIBRESP and EIBRESP2 (29 EIB fields, COBOL PICTURE per field); CICS TS Data Areas: EIB - EXEC interface block (DFHEIBLK layout, offsets, reserved fields); CICS TS 5.3: EIB fields (cross-check of the same 29 names and pictures); CICS TX 10.1: EXEC interface block (EIB) fields (adds EIBLABEL, COBOL-only); TXSeries for Multiplatforms 11.1: EXEC interface block (EIB) fields (second attestation of EIBLABEL); IBM APAR PI88564 (CICS standalone translator for COBOL): DFHEIGDI, EIBCPOSN, EIBCALEN generated COMP/COMP-5; CICS TS 5.6: COBOL translation output (copybooks DFHEIBLK and DFHEIBLC); IMS 15.4 Application Programming: Specifying the DL/I interface block (DIB) - COBOL variable names and PICTUREs; IMS 13 Application Programming: Specifying the DIB (older edition - shows the fillers absent from the COBOL list); Db2 13 for z/OS SQL Reference: The included SQLCA (COBOL declaration generated by INCLUDE SQLCA); Db2 13 for z/OS SQL Reference: Description of SQLCA fields (per-field data types; SQLCADE note); Db2 13 for z/OS SQL Reference: The included SQLDA (COBOL declaration generated by INCLUDE SQLDA); Db2 13 for z/OS SQL Reference: SQLDA field descriptions
26
- // Intrinsic functions of COBOL across editions and vendors, re-derived from: IBM Enterprise COBOL for z/OS 6.4 Language Reference (SC27-8713) and 6.2/6.3/6.4 What's New; Micro Focus COBOL Language Reference (Visual COBOL 3.0 PU12 and reuze 60d); ACUCOBOL-GT 10.0.1 Reference Manual Appendix F; FUJITSU Software NetCOBOL V11.0 User's Guide B1WD-3306-01ENZ0 Appendix D; Veryant isCOBOL Evolve 2021R2 Appendix D; NIST SP 500-203 (ANSI X3.23A-1989 intrinsic function addendum); INCITS announcement of ISO/IEC 1989:2023 with the third edition's change list; ISO/IEC 1989:2014 and :2023 free previews - Enterprise COBOL for z/OS 6.4 Language Reference, Part 7 'Intrinsic functions' (one child topic per function, each named and defined); '2002/2014 COBOL Standard features implemented in Enterprise COBOL V3 or later' - rows 'New intrinsic functions' and 'Support for industry standard date and time formats'; 'IBM extensions and COBOL standards' - list of functions that are extensions to the 85 COBOL Standard; Enterprise COBOL 6.2 What's New - 'added as part of the 2014 COBOL Standard' list and 'added as IBM extensions' list; Enterprise COBOL 6.3 What's New - 'Support for 2002 COBOL Standard' vs 'Support for 2014 COBOL Standard' date/time function lists; Enterprise COBOL 6.4 What's New - new CONTENT-OF intrinsic function, user-defined functions and function prototypes; Micro Focus Visual COBOL 3.0 PU12, COBOL Language Reference, 'Definitions of Functions' table (live microfocus.com now serves a JS marketing shell; retrieved from the Internet Archive copy of the vendor page); Micro Focus COBOL Language Reference, 'Intrinsic Functions' chapter intro; Micro Focus COBOL Language Reference, 'Definitions of Functions' table; ACUCOBOL-GT 10.0.1 Reference Manual, Appendix F 'Intrinsic Functions' > 'Function Definitions' table (live page now a JS marketing shell; Internet Archive copy of the vendor page); FUJITSU Software NetCOBOL V11.0 User's Guide (B1WD-3306-01ENZ0), Appendix D 'Intrinsic Function List', Table D.1 (software.fujitsu.com now answers curl with a JS security checkpoint; Internet Archive copy of the vendor PDF); Fujitsu NetCOBOL FAQ #3880, which spells the UCS2-OF function name in text (used only to attest that spelling); Veryant isCOBOL Evolve 2021R2, Appendices > 'Intrinsic Functions' - 'The table below shows all available intrinsic functions'; NIST SP 500-203, Conformance test specifications for COBOL intrinsic function module - the 42 functions of ANSI X3.23A-1989 (the Intrinsic Function Addendum carried into the later editions); INCITS (the US national body for COBOL) announcement of ISO/IEC 1989:2023, reproducing the third edition's 'The main changes are as follows' list - the COUNT-family evidence; ISO/IEC 1989:2023 free preview (cover, copyright page and Contents pages iii-xv): confirms the 2023 structure, including new subclause '9.1.18 Commit and Rollback'; truncated before clause 15 'Intrinsic functions'; ISO/IEC 1989:2014 free preview (Contents pages iii-xv): clause 15 'Intrinsic functions' begins at page 627 and the Contents stops at 15.3, so the per-function subclauses are not in the preview; RM/COBOL Language Reference Manual, Second Edition (Version 12, Liant Software, copyright 1985-2008, as served by supportline.microfocus.com) - negative check: no intrinsic function chapter, no occurrence of 'intrinsic', so this dialect contributed no words
27
- // ISO/IEC 1989, Information technology - Programming languages, their environments and system software interfaces - Programming language COBOL. Re-derived from the two public draft texts of the standard that are reachable without a paywall: (1) ISO/IEC FCD 1989:2001 (E), Final Committee Draft, working document ISO/IEC JTC 1/SC 22/WG 4 N 0147, dated 2001-01-15, circulated by the SC 22 secretariat as SC 22 N 3204 - this is the draft of the edition published as ISO/IEC 1989:2002; and (2) ISO/IEC 1989:20xx CD 1.2 (E), Committee Draft International Standard, dated 2009-08-23, distributed as file std.zip by the INCITS PL22.4 (formerly J4) COBOL Task Group - this is a draft on the track to ISO/IEC 1989:2014. The official ISO previews of ISO/IEC 1989:2014 and ISO/IEC 1989:2023 (front matter only) were used to confirm clause numbering but contain no word lists. - ISO/IEC FCD 1989:2001 (WG4 N 0147): 8.9 Reserved words, 8.10 Context-sensitive words, 8.11 Intrinsic function names, 8.12 Compiler-directive reserved words, Table 13 Exception-names; SC22 document register entry identifying N3204 as "FCD Ballot on FCD 1989 ... Cobol" (provenance); Archived INCITS PL22.4 (formerly J4) COBOL Task Group distribution of the working draft standard; contains the single member STD.BK.pdf; ISO/IEC 1989:20xx CD 1.2, dated 2009-08-23 (ISO/IEC 1989:2014 track): 8.9 Reserved words, 8.10 Context-sensitive words, 8.11 Intrinsic function names, 8.12 Compiler-directive words, Table 14 Exception-names; ISO/IEC 1989:2023 official preview (cover plus Contents through page xv only): confirms that the 2023 edition still carries 8.9 Reserved words (p.205) and 8.11 Intrinsic function names (p.213); contains no word lists; ISO/IEC 1989:2014 official preview (cover plus Contents through page xv only): 8.9 Reserved words (p.167), 8.11 Intrinsic function names (p.173), 15 Intrinsic functions (p.627); contains no word lists; IBM COBOL for Linux on x86 1.2 Language Reference, "Reserved words": corroboration only. Its third column "Potential reserved words" is stated to include "words reserved in the 2002 COBOL Standard"
28
- // Micro Focus Visual COBOL 9.0 COBOL Language Reference - Reserved Words Table, Context-sensitive Words Table, COBOL Words, Special registers, Definitions of Functions, The Special-Names Paragraph; with Micro Focus Net Express 3.1 Language Reference, Appendix D: Reserved Words - Reserved Words Table (and the dialect-code legend); Context-sensitive Words Table; Reserved Words (appendix front matter); COBOL Words (category definitions); Special registers; Definitions of Functions (intrinsic functions); Intrinsic Functions (chapter front matter); The Special-Names Paragraph (implementor-names = system-names); Net Express 3.1 Language Reference, Appendix D: Reserved Words
29
- // Reserved-word appendices of six independent COBOL implementations: Veryant isCOBOL Evolve 2025 R1 Appendices, Appendix A 'isCOBOL Reserved Words'; Heirloom Computing Elastic COBOL Language Reference Manual Appendix, revision August 2012, Appendix A 'COBOL Reserved Words' and Appendix B 'Elastic COBOL Reserved Words'; Stratus VOS COBOL Language R010-03, Appendix A 'COBOL Reserved Words'; HP COBOL Manual for TNS and TNS/R Programs, part number 522555-006, Section 21 'Reserved Words'; Unisys COBOL ANSI-85 Programming Reference Manual Volume 1, Basic Implementation, form 8600 1518-307 (February 2003), Appendix B 'Reserved Words'; VSI COBOL Reference Manual, VSI COBOL Version 3.1-7 for OpenVMS, Appendix A 'VSI COBOL for OpenVMS Reserved Words' - Stratus VOS COBOL Language (R010-03), Appendix A 'COBOL Reserved Words' - word source; Stratus VOS COBOL Language (R010-03), 'COBOL Words' - consulted to test whether the COMP-n digits are enumerated anywhere (they are not); Veryant isCOBOL Evolve 2025 R1, Appendices, Appendix A 'isCOBOL Reserved Words' - word source; Veryant isCOBOL 2025 R1 Language Reference contents - corroborates hyphen spelling (WORKING-STORAGE, SPECIAL-NAMES, FILE-CONTROL, I-O-CONTROL); Veryant isCOBOL 2025 R1 Language Reference, PERFORM - corroborates hyphen spelling (END-PERFORM); Heirloom Computing, Elastic COBOL Language Reference Manual Appendix (rev. August 2012), Appendix A 'COBOL Reserved Words' and Appendix B 'Elastic COBOL Reserved Words' - word source; Heirloom Computing, Elastic COBOL Language Reference Manual - consulted for a separate intrinsic-function name list; its chapter 15 defines function semantics but publishes no extractable name table; HP COBOL Manual for TNS and TNS/R Programs (HP part number 522555-006), Section 21 'Reserved Words', sub-lists 'All Reserved Words' and 'HP Reserved Words' - word source; Unisys COBOL ANSI-85 Programming Reference Manual Volume 1, Basic Implementation (form 8600 1518-307, Feb 2003), Appendix B 'Reserved Words' - word source; VSI COBOL Reference Manual, VSI COBOL Version 3.1-7 for OpenVMS, Appendix A 'VSI COBOL for OpenVMS Reserved Words' - word source; COBOL-IT Compiler Suite Getting Started v4.1 - PROVENANCE EVIDENCE ONLY, no words taken from it: establishes the OpenCOBOL lineage on which COBOL-IT was excluded; Broadcom TechDocs 'CA Realia II Workbench' bookshelf - GAP EVIDENCE: names the COBOL Reference Guide 3.3 (b009451e.pdf) and 3.2 (b009341e.pdf) whose PDFs sit behind Broadcom OAuth
13
+ // ACUCOBOL-GT Appendices v9.0.1, Appendix B "ACUCOBOL-GT Reserved Words" and Appendix F
14
+ // "Intrinsic Functions"; ACUCOBOL-GT Reference Manual v8.1.3; Appendices, ACUCOBOL-GT v8.1.3;
15
+ // RM/COBOL Language Reference Manual, Second Edition (Version 12, Liant Software), Appendix A
16
+ // "Reserved Words"; RM/COBOL Language Reference Manual Version 8.0 - ACUCOBOL-GT Appendices
17
+ // v9.0.1, Appendix B.2 Reserved Word List (primary source for ACUCOBOL words); ACUCOBOL-GT
18
+ // Appendices v9.0.1, Appendix B.1 Conventions (the dialect-marker legend); ACUCOBOL-GT
19
+ // Appendices v9.0.1, Appendix F.2.1 Function Definitions (intrinsic function table); ACUCOBOL-GT
20
+ // Appendices v9.0.1 WebWorks page manifest; its section titles "F.n <NAME> Function"
21
+ // independently name every intrinsic function; ACUCOBOL-GT User's Guide v9.0.1 section 2.2.9
22
+ // Reserved Word Options (-R2/-R8/-Ra/-Ri/-Rr/-Rs/-Rv: the compiler switches that correspond to
23
+ // the appendix markers); Appendices, ACUCOBOL-GT v8.1.3 (Micro Focus) - Appendix B Reserved
24
+ // Words and Appendix F Intrinsic Functions; second, independent extraction of the same two
25
+ // lists; Reference Manual, ACUCOBOL-GT v8.1.3 (Micro Focus) - special registers, SPECIAL-NAMES
26
+ // system-names, ACCEPT FROM DATE YYYYMMDD syntax; RM/COBOL Language Reference Manual, Second
27
+ // Edition (Version 12, Liant Software, copyright 1985-2008, as served by
28
+ // supportline.microfocus.com) - Appendix A Reserved Words, Table 37 Context-Sensitive Words,
29
+ // Tables 38-42 Nonreserved System-Names, and Chapter 1 Special Registers; RM/COBOL Language
30
+ // Reference Manual Version 8.0 (Liant Software) - Appendix A Reserved Words; cross-check of the
31
+ // v12 list
32
+ // CICS Transaction Server for z/OS Version 5 Release 3, Application Programming Reference
33
+ // (SC34-7402-00), Appendix H 'BMS-related constants' - Appendix H, BMS-related constants: Table
34
+ // 24 (DFHBMSCA) and Table 1 (DFHAID)
35
+ // Fujitsu BS2000 COBOL2000 V1.6 COBOL Compiler Reference Manual; Fujitsu BS2000 COBOL85 V2.3A
36
+ // Reference Manual (U3979-J-Z125-6-7600); FUJITSU Software NetCOBOL V11.0 Language Reference
37
+ // (B1WD-3304-02ENZ0(00), October 2014); Bull DPS7000/XTA NOVASCALE 7000 GCOS 7 COBOL85 Reference
38
+ // Manual (47 A2 05UL 04, November 1997) - COBOL2000 V1.6 Reference Manual, "COBOL words":
39
+ // reserved words, compiler-directive words, context-sensitive words, special registers
40
+ // (English); COBOL2000 V1.6 Sprachbeschreibung, "COBOL-Woerter" (German edition; fetched only to
41
+ // confirm the reserved words are the English COBOL words); COBOL2000 V1.6 Reference Manual,
42
+ // "Overview of intrinsic functions" (English); COBOL2000 V1.6 COBOL Compiler Reference Manual,
43
+ // full PDF (English): corroborates the HTML parse; implementor-name Table 8; ASSIGN device
44
+ // names; BS2000 COBOL85 V2.3A Reference Manual, U3979-J-Z125-6-7600 (English): reserved words
45
+ // table, special registers Table 2-5, implementor-names Table 3-1; FUJITSU Software NetCOBOL
46
+ // V11.0 Language Reference, B1WD-3304-02ENZ0(00), October 2014 (English): Appendix A List of
47
+ // Reserved Words, intrinsic functions, special registers, SPECIAL-NAMES function-names; Bull
48
+ // DPS7000/XTA NOVASCALE 7000 GCOS 7 COBOL85 Reference Manual, 47 A2 05UL 04, November 1997
49
+ // (English): Appendix A COBOL Reserved Words, special registers
50
+ // User Interface Programming, ACUCOBOL-GT Version 8.1.3 (Micro Focus,
51
+ // E-01-UI-100501-ACUCOBOL-GT-8.1.3); Reference Manual, ACUCOBOL-GT Version 8.1.3 (Micro Focus);
52
+ // Appendices, ACUCOBOL-GT Version 8.1.3 (Micro Focus); ACUCOBOL-GT User's Guide Version 9.0.1
53
+ // section 2.2.9 and Appendices Version 9.0.1 Appendix B.2; RM/COBOL Language Reference Manual,
54
+ // Second Edition (Version 12, Liant Software), Appendix A Table 37; RM/COBOL Language Reference
55
+ // Manual Version 8.0 (Liant Software), Appendix A Table A-1 - User Interface Programming,
56
+ // ACUCOBOL-GT 8.1.3 (form E-01-UI-100501-ACUCOBOL-GT-8.1.3). Primary source for this pass: 3.2
57
+ // Control Types, Handles, and IDs; 4.4 Styles and Special Properties; Chapter 5 Control Types
58
+ // Reference, whose per-control 5.n.1 Common Properties / STYLES and 5.n.2 Special Properties
59
+ // lists define every style and special property; 5.2 Global Styles; Chapter 6 Events Reference;
60
+ // and the manual index, which repeats each property as '<WORD>, <CONTROL-TYPE> style|special
61
+ // property <page>'; Reference Manual, ACUCOBOL-GT 8.1.3. Used for 5.8 Screen Section general
62
+ // format (5-92..5-94), 6.4.9 Common Screen Options (EVENT-LIST / AX-EVENT-LIST /
63
+ // EXCLUDE-EVENT-LIST at 6-34, MAX-HEIGHT / MAX-WIDTH / MIN-HEIGHT / MIN-WIDTH at 6-43), 6.6
64
+ // DISPLAY Formats 11 and 12 (window phrases MIN-SIZE, MAX-SIZE, MIN-LINES, MAX-LINES, NO-CLOSE
65
+ // at 6-186..6-196), and the ACCEPT ... FROM STANDARD OBJECT 'Object-Name / Resource' table at
66
+ // 6-92..6-93; Appendices, ACUCOBOL-GT 8.1.3. Appendix B Reserved Words (the list these words are
67
+ // missing from, and the source of the alphabet-heading letters), Appendix H Configuration
68
+ // Variables and Appendix I Library Routines (where STDIN, TIMESTAMP, WINAPI, XOR, STDOUT, STDERR
69
+ // turn out to live); ACUCOBOL-GT User's Guide 9.0.1, 2.2.9 Reserved Word Options. The -Rw entry
70
+ // is the vendor's own statement that control names and property names are NOT reserved words:
71
+ // 'This option also allows you to suppress some non-reserved words, such as control names (e.g.,
72
+ // "entry-field", "label") or property names (e.g., "max-text", "bitmap-number").'; ACUCOBOL-GT
73
+ // Appendices 9.0.1, Appendix B.2 Reserved Word List. Re-parsed here only as a negative control:
74
+ // 629 tokens harvested, and not one of the 86 words attested below appears in it; RM/COBOL
75
+ // Language Reference Manual, Second Edition (Version 12, Liant Software, copyright 1985-2008, as
76
+ // served by supportline.microfocus.com), Appendix A, Table 37 'Context-Sensitive Words' - the
77
+ // table that attests BACKGROUND, CASE-INSENSITIVE, END-COPY, END-REPLACE, FOREGROUND, TRIMMED,
78
+ // WHILE; RM/COBOL Language Reference Manual Version 8.0 (Liant Software). Appendix A, Table A-1
79
+ // 'Context-Sensitive Words', which carries BACKGROUND, CASE-INSENSITIVE, FOREGROUND and TRIMMED
80
+ // but not END-COPY, END-REPLACE or WHILE
81
+ // Adjudication of the 21 residue words against the first pass's 230-file corpus plus newly
82
+ // searched vendor documentation. Documents relied on: ACUCOBOL-GT 8.1.3 User Interface
83
+ // Programming, 8.1.3 Reference Manual, 8.1.3 Appendices and 9.0.1 Appendices Appendix B.2
84
+ // Reserved Word List; Heirloom Computing Elastic COBOL Language Reference Manual Appendix
85
+ // (August 2012); Micro Focus Visual COBOL 9.0 Reserved Words Table and Context-sensitive Words
86
+ // Table; IBM Enterprise COBOL for z/OS 6.4 'Reserved words'; IBM COBOL for VSE/ESA Language
87
+ // Reference SC26-8073-02 Table 48; Veryant isCOBOL Evolve 2021R2 Appendix D 'Intrinsic
88
+ // Functions' and isCOBOL Evolve 2023 R1 Overview; RM/COBOL Language Reference Manual, Second
89
+ // Edition (Version 12, Liant Software); Unisys COBOL ANSI-85 Programming Reference Manual Vol.1
90
+ // (86001518-307); ISO/IEC 1989:20xx CD 1.2 (2009-08-23); COBOL Consortium (Japan) summary of
91
+ // ISO/IEC 1989:2023 - ACUCOBOL-GT 8.1.3 User Interface Programming, ch.5 FRAME 'special
92
+ // properties': the LOW-COLOR property definition entry at 5-70 and the index entry 'LOW-COLOR,
93
+ // FRAME special property 5-70'; Heirloom Computing, Elastic COBOL Language Reference Manual
94
+ // Appendix (rev. August 2012): FRAME 'Properties Table' p.69 with columns
95
+ // Name/MODIFY/INQUIRE/Descriptions, the BAR 'Properties Table', and the copybook constants list
96
+ // (FP-*, BRS-*); Micro Focus Visual COBOL 9.0, Context-sensitive Words Table: the full GUI
97
+ // property-word set including every BITMAP-prefixed word, TRANSPARENT-COLOR, DOT-DASH and
98
+ // NO-TAB; Micro Focus Visual COBOL 9.0, Reserved Words Table: METACLASS, UNEQUAL, and the
99
+ // BINARY-CHAR/-SHORT/-LONG/-DOUBLE usage set; IBM Enterprise COBOL for z/OS 6.4, appendix
100
+ // 'Reserved words': EGCS, and the BINARY-CHAR/-SHORT/-LONG/-DOUBLE usage set; IBM COBOL for
101
+ // VSE/ESA Language Reference, SC26-8073-02, Table 48 'Reserved Words' p.454: the sequence AREA,
102
+ // AREA-VALUE, AREAS; ACUCOBOL-GT 9.0.1 Appendices, Appendix B.2 Reserved Word List: 624 distinct
103
+ // words, containing no GUI property names at all; ACUCOBOL-GT 8.1.3 Reference Manual, Procedure
104
+ // Division relation-condition general format '{ IS UNEQUAL TO obj-item }' at 6-222; Veryant
105
+ // isCOBOL Evolve 2021R2, Appendix D 'Intrinsic Functions': the complete table of all 66
106
+ // intrinsic functions isCOBOL provides; Veryant isCOBOL Evolve 2023 R1 Overview: the only
107
+ // literal 'Content-Length' in the entire corpus, an HTTP response header inside a logged SOAP
108
+ // trace; RM/COBOL Language Reference Manual, Second Edition (Version 12, Liant Software,
109
+ // copyright 1985-2008, as served by supportline.microfocus.com): ACCEPT/FULL prose using the
110
+ // phrase 'field terminator'; ACUCOBOL-GT 8.1.3 Appendices: the line-drawing figure enumeration
111
+ // whose item 10 reads 'missing right line'; Unisys COBOL ANSI-85 Programming Reference Manual
112
+ // Vol.1 (86001518-307): VREADTIMER prose 'the ACCEPT statement with the TIMER option for the
113
+ // microsecond timer'; COBOL Consortium (Japan), overview of the new features of the 2023 edition
114
+ // of the COBOL international standard; the only new word-like items it names are SHIFT-L,
115
+ // SHIFT-LC, SHIFT-R, SHIFT-RC; ISO/IEC 1989:20xx CD 1.2 dated 2009-08-23, full 910-page text
116
+ // (zip member STD.BK.pdf), searched for every candidate intrinsic-function name in this scope
117
+ // Bull DPS7000/XTA GCOS 7 COBOL 85 Reference Manual (47 A2 05UL Rev04, November 1997); FUJITSU
118
+ // Software NetCOBOL V11.0 Language Reference (B1WD-3304-02ENZ0(00), October 2014); Fujitsu
119
+ // BS2000 COBOL85 V2.3A Reference Manual (U3979-J-Z125-6-7600) and BS2000 COBOL2000 V1.6 COBOL
120
+ // Compiler Reference Manual; IBM Enterprise COBOL for z/OS V6.4 Language Reference
121
+ // (SC27-8713-03) with its IBM Docs 'SPECIAL-NAMES paragraph' and 'Reserved words' topics; HP
122
+ // COBOL II/XL Reference Manual (HP 3000 / MPE iX, doc id B3150090013); Heirloom Computing
123
+ // Elastic COBOL Language Reference Manual; Unisys COBOL ANSI-85 Programming Reference Manual
124
+ // Volume 1 (8600 1518-307, February 2003); HP COBOL Manual for TNS and TNS/R Programs
125
+ // (522555-006); ACUCOBOL-GT Reference Manual and Appendices v8.1.3; Micro Focus Visual COBOL 6.0
126
+ // COBOL Language Reference, 'Switch-Names'; COBOL Consortium of Japan, '2023 nen-ban COBOL
127
+ // kokusai kikaku no shin-kinou no gaiyou'; INCITS, 'Available Now - 2023 Edition of ISO/IEC
128
+ // 1989, COBOL' - Bull DPS7000/XTA GCOS 7 COBOL 85 Reference Manual, 47 A2 05UL Rev04 (Nov 1997):
129
+ // Appendix A 'COBOL Reserved Words' (pp. A-1..A-16 = PDF pp. 611-626), chapter 3 'System-Names',
130
+ // Appendix C 'The ANSI Flagger'; FUJITSU Software NetCOBOL V11.0 Language Reference,
131
+ // B1WD-3304-02ENZ0(00) (Oct 2014): 6.2 'Procedure Division Header' Format (p.238), 6.4.6 CALL
132
+ // statement Formats 1 and 2 (pp.277-279), Appendix A 'List of Reserved Words' (pp.684-704),
133
+ // SPECIAL-NAMES function-name-2 SWITCH-n rule (p.92); Fujitsu BS2000 COBOL85 V2.3A Reference
134
+ // Manual, U3979-J-Z125-6-7600: glossary entry 'Implementor-name' (p.21), Table 3-1
135
+ // 'Implementor-names and their meanings' (p.126), reserved-words list row 'USW-1...USW-31'
136
+ // (p.58); Fujitsu BS2000 COBOL2000 V1.6 COBOL Compiler Reference Manual: glossary entry
137
+ // 'Implementor-name', Table 8 'Implementor-names and their meanings' (6.2.3.1, pp.199-200); IBM
138
+ // Enterprise COBOL for z/OS V6.4 Language Reference, SC27-8713-03: OCCURS clause 'Format 2:
139
+ // variable-length tables' and the UNBOUNDED syntax-element description (p.203); ALLOCATE
140
+ // statement Format and 'LOC phrase' (pp.313-315); XML GENERATE statement Format,
141
+ // 'XML-DECLARATION phrase' and 'NAMESPACE and NAMESPACE-PREFIX phrases' (p.483ff); XML PARSE
142
+ // statement Format and 'VALIDATING phrase'; IBM Enterprise COBOL for z/OS 6.4, 'SPECIAL-NAMES
143
+ // paragraph': the environment-name-2 entry that states the UPSI range; IBM Enterprise COBOL for
144
+ // z/OS 6.4, appendix 'Reserved words' (one table; columns Word / Reserved / Standard only /
145
+ // Potential reserved words; 515 word rows) - the negative check for the IBM candidates; COBOL
146
+ // Consortium of Japan (COBOL ), '2023 COBOL ' by Wataru Takagi (Hitachi), 2024-10-08, updated
147
+ // 2025-05-16: item (3) names the four boolean shift operators added by ISO/IEC 1989:2023;
148
+ // INCITS, 'Available Now - 2023 Edition of ISO/IEC 1989, COBOL': reproduces the ISO/IEC
149
+ // 1989:2023 foreword 'main changes' list, which includes '- Boolean shifting operators'
150
+ // (corroborates the feature; does not name the words); Reference Manual, ACUCOBOL-GT v8.1.3:
151
+ // SPECIAL-NAMES paragraph, Syntax Rule 1 - the ACUCOBOL switch-name range (pp.4-6/4-7);
152
+ // Appendices, ACUCOBOL-GT v8.1.3: Appendix D 'List of Errors', messages 'Invalid switch number',
153
+ // 'Missing switch number' and 'Unknown switch' - each restates the SWITCH-1..SWITCH-26 range;
154
+ // Heirloom Computing, Elastic COBOL Language Reference Manual: SWITCH clause general rule 4,
155
+ // 'Certain aliases exist for the switches for compatibility with more platforms', and its
156
+ // Name/Synonyms table (PDF pp.144-145), which names UPSI-0 through UPSI-9; Unisys COBOL ANSI-85
157
+ // Programming Reference Manual Volume 1, 8600 1518-307 (Feb 2003): SPECIAL-NAMES switch-name
158
+ // clause - the Unisys SW1..SW8 range; HP COBOL Manual for TNS and TNS/R Programs, 522555-006:
159
+ // 'System-Name Clause With a STATUS Phrase' - the HP NonStop SWITCH-1..SWITCH-15 range; HP COBOL
160
+ // II/XL Reference Manual (HP 3000, MPE/iX 5.0 documentation, doc id B3150090013; 3kranger.com
161
+ // HTTrack mirror of docs.hp.com), 'SPECIAL-NAMES Paragraph': Table 6-1 'HP COBOL II Feature,
162
+ // Switch, and Device Names' with the Switch Name row 'SW0 through SW15', and the 'Software
163
+ // Switches' subsection; HP COBOL II/XL Reference Manual, Appendix F 'COBOL Reserved Word List',
164
+ // Table F-1 - negative check: the SWn switch-names are not in it; Micro Focus Visual COBOL 6.0
165
+ // COBOL Language Reference, 'Switch-Names' (Environment Division) - the Micro Focus switch
166
+ // numbering
167
+ // ISO/IEC 1989, Information technology - Programming languages, their environments and system
168
+ // software interfaces - Programming language COBOL. Re-derived from the three full draft texts
169
+ // reachable without a paywall: (1) ISO/IEC FCD 1989:2001 (E), Final Committee Draft, working
170
+ // document ISO/IEC/JTC 1/SC 22/WG 4 N 0147, 2001-01-15, 891 pp, circulated by the SC 22
171
+ // secretariat as SC 22 N 3204 - the draft of the edition published as ISO/IEC 1989:2002; (2)
172
+ // ISO/IEC 1989:20xx CD 1.2 (E), Committee Draft International Standard, 2009-08-23, 910 pp,
173
+ // distributed as std.zip by INCITS PL22.4 (formerly J4); and (3) ISO/IEC 1989:20xx FCD 1.0 (E),
174
+ // Final Committee Draft International Standard, 2010-07-13, 901 pp, circulated as SC 22 N 4561
175
+ // 'Text for FCD ballot or comment' - the latest full text on the track to ISO/IEC 1989:2014,
176
+ // fetched by this pass. Clause numbering of the published editions was confirmed against the
177
+ // official Contents-only previews of ISO/IEC FDIS 1989:2013, ISO/IEC 1989:2014 and ISO/IEC
178
+ // 1989:2023. - ISO/IEC FCD 1989:2001 (E) (WG4 N 0147), 891 pp: 8.9 Reserved words p.140, 8.10
179
+ // Context-sensitive words p.143, 8.12 Compiler-directive reserved words p.146, 8.2 Locales p.59
180
+ // and 8.2.1 Locale field names p.60, 14.7.11.2.5 Exception-names and exception conditions with
181
+ // Table 13 pp.401-405; ISO/IEC 1989:20xx CD 1.2 (E), 2009-08-23, 910 pp: 8.9 Reserved words
182
+ // p.154, 8.10 Context-sensitive words p.157, 8.12 Compiler-directive words p.161, 7.3.20 TURN
183
+ // directive p.58, 8.2 Locales p.65 and 8.2.1 Locale field names p.66, 14.6.12.1.5
184
+ // Exception-names and exception conditions with Table 14 pp.422-427, 14.6.12.2 Incompatible data
185
+ // p.427; NEW THIS PASS. SC 22 N 4561, 'Text for FCD ballot or comment', dated 2010-08-06,
186
+ // carrying the full ISO/IEC 1989:20xx FCD 1.0 (E) of 2010-07-13, 901 pp - the latest full draft
187
+ // text of the 2014 edition that is publicly reachable: 8.9 Reserved words p.156, 8.10
188
+ // Context-sensitive words p.159, 8.12 Compiler-directive words p.163, 14.6.12.1.5
189
+ // Exception-names and exception conditions with Table 14 p.426; ISO/IEC 1989:2014 official
190
+ // preview, cover plus Contents to p.xv: 8.9 Reserved words p.167, 8.10 Context-sensitive words
191
+ // p.170, 8.12 Compiler-directive words p.174, 11.9.7 FLOAT-BINARY clause and 11.9.8
192
+ // FLOAT-DECIMAL clause p.220. No word lists; ISO/IEC FDIS 1989:2013 (E) official preview, voting
193
+ // 2013-09-18 to 2013-11-18, served under the 2014 catalogue entry 51416; URL re-verified by
194
+ // sha256 this pass. Contents only, carrying 11.9.7 FLOAT-BINARY clause and 11.9.8 FLOAT-DECIMAL
195
+ // clause. No word lists; ISO/IEC 1989:2023 official preview, cover plus Contents to p.xv:
196
+ // 8.5.2.9 Message-tag category p.164, 8.9 Reserved words p.205, 8.10 Context-sensitive words
197
+ // p.209, 11.9.8 FLOAT-BINARY clause and 11.9.9 FLOAT-DECIMAL clause p.275. No word lists; INCITS
198
+ // PL22.4 (J4) 08-0116 (S-16), 'Candidate features for a future revision'. Cited only for the
199
+ // negative finding on EXCLUSIVE-OR; Archived INCITS PL22.4 (J4) document index, 2016 snapshot.
200
+ // Cited only for the negative findings on FLOAT-DECIMAL-7 and ENGRAVED. The first pass did not
201
+ // record the exact Wayback timestamp and web.archive.org answered 'Temporarily Offline' during
202
+ // this pass, so the URL is given in the date-prefix form; RM/COBOL Language Reference Manual,
203
+ // Second Edition (Version 12, Liant Software, copyright 1985-2008, as served by
204
+ // supportline.microfocus.com). Cited only for the negative finding on CURRENCY-SYMBOL, which
205
+ // occurs there solely inside the RUN-ATTR configuration keyword EDIT-CURRENCY-SYMBOL
206
+ // Micro Focus Visual COBOL 9.0 COBOL Language Reference, appendix "Context-sensitive Words
207
+ // Table" (topic id HRLHLHARES04), with the same manual's "Reserved Words Table"
208
+ // (HRLHLHARES01U005) and "Special registers" (HRLHLHCLANU020); Micro Focus Net Express 3.1
209
+ // Language Reference (Appendix D "Reserved Words", lrares.htm, and Chapter 2 "COBOL Language",
210
+ // lrclan.htm); and Micro Focus Server Express 6.0 Language Reference, "reuze" doc set
211
+ // (lhclan.htm). Micro Focus publishes these HTML topic sets without form numbers; the topic ids
212
+ // above are the documents' own DC.Identifier values. - Appendix: Context-sensitive Words Table
213
+ // (DC.Identifier HRLHLHARES04) - the table that attests all 181 words; Appendix: Reserved Words
214
+ // Table, with the dialect-code legend - checked as negative evidence: none of the 13 hunted
215
+ // registers, and none of the 181, is a row of it; Special registers, Table 1 (Visual COBOL 9.0)
216
+ // - read in full; ADDRESS OF, CURRENT-DATE, DEBUG-ITEM, JSON-CODE, JSON-STATUS, LENGTH OF,
217
+ // LINAGE-COUNTER, RETURN-CODE, SHIFT-IN, SHIFT-OUT, SORT-*, TALLY, TIME-OF-DAY, WHEN-COMPILED,
218
+ // XML-* only; Net Express 3.1 Language Reference, Appendix D: Reserved Words - the file cited
219
+ // for 7 words; the string is an unrendered HTML comment at the head of D.3 and is NOT used as
220
+ // attestation; Net Express 3.1 Language Reference, Chapter 2 COBOL Language - 2.2.4.6 Special
221
+ // Registers (12-row table) and 2.2.4.7 Predefined Object Identifiers; fetched by this pass as
222
+ // negative evidence for the 13; Server Express 6.0 ('reuze') Language Reference, COBOL Language
223
+ // chapter - Table 2: Special Registers (22 rows); fetched live by this pass as negative evidence
224
+ // for the 13
225
+ // GnuCOBOL Programmer’s Guide, for GnuCOBOL 3.2 (15 January 2023 build), Gary L. Cutler and
226
+ // Vincent B. Coen - 8.1.11 CONCAT and CONCATENATE, 8.1.58 MODULE-CALLER-ID, 8.1.61 MODULE-ID,
227
+ // 8.1.63 MODULE-SOURCE (Intrinsic Functions); 7.7 Special Registers (NUMBER-OF-CALL-PARAMETERS);
228
+ // 7.8.1.5 ACCEPT FROM DATE/TIME (MICROSECOND-TIME); 7.7 Special Registers and Appendix C1
229
+ // Internal registers (COB-CRT-STATUS); 8.1.59, 8.1.60, 8.1.62, 8.1.64 and Appendix C2 Intrinsic
230
+ // Functions (MODULE-DATE, MODULE-FORMATTED-DATE, MODULE-PATH, MODULE-TIME); 8.1.88, 8.1.89 and
231
+ // Appendix C2 (SUBSTITUTE, SUBSTITUTE-CASE); 5.1.3 SPECIAL-NAMES rule 14 and Appendix C4 System
232
+ // names: device (STDIN, STDOUT, STDERR); Appendix C1 Common reserved words (B-SHIFT-L,
233
+ // B-SHIFT-R, B-SHIFT-LC, B-SHIFT-RC, NOTHING, NONNUMERIC, NESTED, FLOAT-INFINITY, PHYSICAL,
234
+ // ACTIVATING, TOP-LEVEL, CURRENT, STACK, ANUM, HEX, NAT, FLOAT-NOT-A-NUMBER, PASCAL, STDCALL);
235
+ // An earlier build of the same guide, which attests five of the seven; CONCAT and
236
+ // MICROSECOND-TIME postdate it
237
+ // IBM Enterprise COBOL for z/OS, V6.4 Language Reference (SC27-8713-03, seventh edition, 28
238
+ // April 2026 update) - Special registers; Intrinsic functions; Function definitions (Table of
239
+ // functions); SPECIAL-NAMES paragraph (Meanings of environment names); WRITE for sequential
240
+ // files (channel environment-names); DEBUG-ITEM special register; Enterprise COBOL for z/OS 6.4
241
+ // Language Reference, complete PDF (SC27-8713-03); Text rendering of the PDF, used for
242
+ // cross-checking only
243
+ // IBM Enterprise COBOL for z/OS, Version 6.4, Language Reference -- appendix "Reserved words"
244
+ // (form number SC27-8713-03, not attested in the fetched bytes) - Reserved words
245
+ // IBM COBOL for AIX 5.1 Language Reference (SC27-5403-00) and its IBM Docs "Reserved words"
246
+ // appendix; IBM COBOL for Linux on x86 1.1/1.2 Language reference (SC28-3117-01) and its
247
+ // "Reserved words" appendix; IBM COBOL for VSE/ESA Language Reference Release 1 (SC26-8073-02)
248
+ // Appendix D; Enterprise COBOL for z/OS Compiler and Runtime Migration Guide V3R4 (GC27-1409-04)
249
+ // Appendix B and Enterprise COBOL for z/OS 6.4 Migration Guide (GC27-8715-03) Appendix B, whose
250
+ // reserved-word comparison tables attest IBM COBOL, VS COBOL II and OS/VS COBOL; IBM VS COBOL
251
+ // for OS/VS Release 2.4 (GC26-3857-3) - IBM COBOL for AIX 5.1 - Appendix "Reserved words" (Table
252
+ // 1), raw HTML table, 512 word rows; IBM COBOL for Linux on x86 1.1 - Appendix "Reserved words"
253
+ // (Table 1), 515 word rows; IBM COBOL for Linux on x86 1.2 - Appendix "Reserved words" (Table
254
+ // 1), 515 word rows; COBOL for AIX Language Reference V5.1, SC27-5403-00 - "Special registers"
255
+ // (p.16-48), "Function-names"/Table 58 table of functions and Chapter 22 function sections,
256
+ // Table 6 "Meanings of environment names" (p.114), Appendix F "Reserved words" (Table 66); IBM
257
+ // COBOL for Linux on x86 1.2 Language reference, SC28-3117-01 - "Special registers", Part 7
258
+ // intrinsic-function chapters, Table 5 "Meanings of environment names" (p.98), "Reserved words"
259
+ // appendix; Enterprise COBOL for z/OS Compiler and Runtime Migration Guide V3R4, GC27-1409-04 -
260
+ // Appendix B "COBOL reserved word comparison", Table 46 (PDF pages 266-283 = book pages
261
+ // 245-262): one row per word, columns Enterprise COBOL / IBM COBOL / VS COBOL II / OS/VS COBOL;
262
+ // Enterprise COBOL for z/OS 6.4 Migration Guide, GC27-8715-03 - Appendix B "COBOL reserved word
263
+ // comparison", Table 55 (PDF pages 328-350), same four columns; used as the second edition of
264
+ // the same table and to adjudicate two disagreements with GC27-1409-04; IBM COBOL for VSE/ESA
265
+ // Language Reference Release 1, SC26-8073-02 - Appendix D "Reserved Words", Table 48 (7 pages,
266
+ // two column-groups per page: COBOL/VSE | Standard Only | RFD); also "Special Registers" (p.8ff)
267
+ // and Table 4 "Meanings of Environment Names"; IBM VS COBOL for OS/VS Release 2.4, GC26-3857-3
268
+ // (the OS/VS COBOL language manual; scanned IBM publication with an OCR text layer, mirrored by
269
+ // bitsavers) - "Reserved words" (book p.15, the six types incl. special registers), APPLY
270
+ // CORE-INDEX format (book p.369), special register LABEL-RETURN (book p.375), FIPS-flagging
271
+ // lists of special registers (book p.343/348), Appendix F "OS/VS COBOL Reserved Word List". Used
272
+ // for adjudication and for two words only, never as a bulk source, because OCR corrupts digits
273
+ // (SKIP1 -> "SKIPI", C01 -> "COl", UPSI-0 -> "UPSI-O")
274
+ // IBM interface-block field definitions: CICS TS 6.x 'EIB fields including EIBRESP and EIBRESP2'
275
+ // and Data Areas 'EIB - EXEC interface block' (DFHEIBLK); IMS 15.4 Application Programming
276
+ // 'Specifying the DL/I interface block (DIB)'; Db2 13 for z/OS SQL Reference 'The included
277
+ // SQLCA', 'Description of SQLCA fields', 'The included SQLDA' and 'SQLDA field descriptions' -
278
+ // CICS TS 6.x: EIB fields including EIBRESP and EIBRESP2 (29 EIB fields, COBOL PICTURE per
279
+ // field); CICS TS Data Areas: EIB - EXEC interface block (DFHEIBLK layout, offsets, reserved
280
+ // fields); CICS TS 5.3: EIB fields (cross-check of the same 29 names and pictures); CICS TX
281
+ // 10.1: EXEC interface block (EIB) fields (adds EIBLABEL, COBOL-only); TXSeries for
282
+ // Multiplatforms 11.1: EXEC interface block (EIB) fields (second attestation of EIBLABEL); IBM
283
+ // APAR PI88564 (CICS standalone translator for COBOL): DFHEIGDI, EIBCPOSN, EIBCALEN generated
284
+ // COMP/COMP-5; CICS TS 5.6: COBOL translation output (copybooks DFHEIBLK and DFHEIBLC); IMS 15.4
285
+ // Application Programming: Specifying the DL/I interface block (DIB) - COBOL variable names and
286
+ // PICTUREs; IMS 13 Application Programming: Specifying the DIB (older edition - shows the
287
+ // fillers absent from the COBOL list); Db2 13 for z/OS SQL Reference: The included SQLCA (COBOL
288
+ // declaration generated by INCLUDE SQLCA); Db2 13 for z/OS SQL Reference: Description of SQLCA
289
+ // fields (per-field data types; SQLCADE note); Db2 13 for z/OS SQL Reference: The included SQLDA
290
+ // (COBOL declaration generated by INCLUDE SQLDA); Db2 13 for z/OS SQL Reference: SQLDA field
291
+ // descriptions
292
+ // Intrinsic functions of COBOL across editions and vendors, re-derived from: IBM Enterprise
293
+ // COBOL for z/OS 6.4 Language Reference (SC27-8713) and 6.2/6.3/6.4 What's New; Micro Focus
294
+ // COBOL Language Reference (Visual COBOL 3.0 PU12 and reuze 60d); ACUCOBOL-GT 10.0.1 Reference
295
+ // Manual Appendix F; FUJITSU Software NetCOBOL V11.0 User's Guide B1WD-3306-01ENZ0 Appendix D;
296
+ // Veryant isCOBOL Evolve 2021R2 Appendix D; NIST SP 500-203 (ANSI X3.23A-1989 intrinsic function
297
+ // addendum); INCITS announcement of ISO/IEC 1989:2023 with the third edition's change list;
298
+ // ISO/IEC 1989:2014 and :2023 free previews - Enterprise COBOL for z/OS 6.4 Language Reference,
299
+ // Part 7 'Intrinsic functions' (one child topic per function, each named and defined);
300
+ // '2002/2014 COBOL Standard features implemented in Enterprise COBOL V3 or later' - rows 'New
301
+ // intrinsic functions' and 'Support for industry standard date and time formats'; 'IBM
302
+ // extensions and COBOL standards' - list of functions that are extensions to the 85 COBOL
303
+ // Standard; Enterprise COBOL 6.2 What's New - 'added as part of the 2014 COBOL Standard' list
304
+ // and 'added as IBM extensions' list; Enterprise COBOL 6.3 What's New - 'Support for 2002 COBOL
305
+ // Standard' vs 'Support for 2014 COBOL Standard' date/time function lists; Enterprise COBOL 6.4
306
+ // What's New - new CONTENT-OF intrinsic function, user-defined functions and function
307
+ // prototypes; Micro Focus Visual COBOL 3.0 PU12, COBOL Language Reference, 'Definitions of
308
+ // Functions' table (live microfocus.com now serves a JS marketing shell; retrieved from the
309
+ // Internet Archive copy of the vendor page); Micro Focus COBOL Language Reference, 'Intrinsic
310
+ // Functions' chapter intro; Micro Focus COBOL Language Reference, 'Definitions of Functions'
311
+ // table; ACUCOBOL-GT 10.0.1 Reference Manual, Appendix F 'Intrinsic Functions' > 'Function
312
+ // Definitions' table (live page now a JS marketing shell; Internet Archive copy of the vendor
313
+ // page); FUJITSU Software NetCOBOL V11.0 User's Guide (B1WD-3306-01ENZ0), Appendix D 'Intrinsic
314
+ // Function List', Table D.1 (software.fujitsu.com now answers curl with a JS security
315
+ // checkpoint; Internet Archive copy of the vendor PDF); Fujitsu NetCOBOL FAQ #3880, which spells
316
+ // the UCS2-OF function name in text (used only to attest that spelling); Veryant isCOBOL Evolve
317
+ // 2021R2, Appendices > 'Intrinsic Functions' - 'The table below shows all available intrinsic
318
+ // functions'; NIST SP 500-203, Conformance test specifications for COBOL intrinsic function
319
+ // module - the 42 functions of ANSI X3.23A-1989 (the Intrinsic Function Addendum carried into
320
+ // the later editions); INCITS (the US national body for COBOL) announcement of ISO/IEC
321
+ // 1989:2023, reproducing the third edition's 'The main changes are as follows' list - the
322
+ // COUNT-family evidence; ISO/IEC 1989:2023 free preview (cover, copyright page and Contents
323
+ // pages iii-xv): confirms the 2023 structure, including new subclause '9.1.18 Commit and
324
+ // Rollback'; truncated before clause 15 'Intrinsic functions'; ISO/IEC 1989:2014 free preview
325
+ // (Contents pages iii-xv): clause 15 'Intrinsic functions' begins at page 627 and the Contents
326
+ // stops at 15.3, so the per-function subclauses are not in the preview; RM/COBOL Language
327
+ // Reference Manual, Second Edition (Version 12, Liant Software, copyright 1985-2008, as served
328
+ // by supportline.microfocus.com) - negative check: no intrinsic function chapter, no occurrence
329
+ // of 'intrinsic', so this dialect contributed no words
330
+ // ISO/IEC 1989, Information technology - Programming languages, their environments and system
331
+ // software interfaces - Programming language COBOL. Re-derived from the two public draft texts
332
+ // of the standard that are reachable without a paywall: (1) ISO/IEC FCD 1989:2001 (E), Final
333
+ // Committee Draft, working document ISO/IEC JTC 1/SC 22/WG 4 N 0147, dated 2001-01-15,
334
+ // circulated by the SC 22 secretariat as SC 22 N 3204 - this is the draft of the edition
335
+ // published as ISO/IEC 1989:2002; and (2) ISO/IEC 1989:20xx CD 1.2 (E), Committee Draft
336
+ // International Standard, dated 2009-08-23, distributed as file std.zip by the INCITS PL22.4
337
+ // (formerly J4) COBOL Task Group - this is a draft on the track to ISO/IEC 1989:2014. The
338
+ // official ISO previews of ISO/IEC 1989:2014 and ISO/IEC 1989:2023 (front matter only) were used
339
+ // to confirm clause numbering but contain no word lists. - ISO/IEC FCD 1989:2001 (WG4 N 0147):
340
+ // 8.9 Reserved words, 8.10 Context-sensitive words, 8.11 Intrinsic function names, 8.12
341
+ // Compiler-directive reserved words, Table 13 Exception-names; SC22 document register entry
342
+ // identifying N3204 as "FCD Ballot on FCD 1989 ... Cobol" (provenance); Archived INCITS PL22.4
343
+ // (formerly J4) COBOL Task Group distribution of the working draft standard; contains the single
344
+ // member STD.BK.pdf; ISO/IEC 1989:20xx CD 1.2, dated 2009-08-23 (ISO/IEC 1989:2014 track): 8.9
345
+ // Reserved words, 8.10 Context-sensitive words, 8.11 Intrinsic function names, 8.12
346
+ // Compiler-directive words, Table 14 Exception-names; ISO/IEC 1989:2023 official preview (cover
347
+ // plus Contents through page xv only): confirms that the 2023 edition still carries 8.9 Reserved
348
+ // words (p.205) and 8.11 Intrinsic function names (p.213); contains no word lists; ISO/IEC
349
+ // 1989:2014 official preview (cover plus Contents through page xv only): 8.9 Reserved words
350
+ // (p.167), 8.11 Intrinsic function names (p.173), 15 Intrinsic functions (p.627); contains no
351
+ // word lists; IBM COBOL for Linux on x86 1.2 Language Reference, "Reserved words": corroboration
352
+ // only. Its third column "Potential reserved words" is stated to include "words reserved in the
353
+ // 2002 COBOL Standard"
354
+ // Micro Focus Visual COBOL 9.0 COBOL Language Reference - Reserved Words Table,
355
+ // Context-sensitive Words Table, COBOL Words, Special registers, Definitions of Functions, The
356
+ // Special-Names Paragraph; with Micro Focus Net Express 3.1 Language Reference, Appendix D:
357
+ // Reserved Words - Reserved Words Table (and the dialect-code legend); Context-sensitive Words
358
+ // Table; Reserved Words (appendix front matter); COBOL Words (category definitions); Special
359
+ // registers; Definitions of Functions (intrinsic functions); Intrinsic Functions (chapter front
360
+ // matter); The Special-Names Paragraph (implementor-names = system-names); Net Express 3.1
361
+ // Language Reference, Appendix D: Reserved Words
362
+ // Reserved-word appendices of six independent COBOL implementations: Veryant isCOBOL Evolve 2025
363
+ // R1 Appendices, Appendix A 'isCOBOL Reserved Words'; Heirloom Computing Elastic COBOL Language
364
+ // Reference Manual Appendix, revision August 2012, Appendix A 'COBOL Reserved Words' and
365
+ // Appendix B 'Elastic COBOL Reserved Words'; Stratus VOS COBOL Language R010-03, Appendix A
366
+ // 'COBOL Reserved Words'; HP COBOL Manual for TNS and TNS/R Programs, part number 522555-006,
367
+ // Section 21 'Reserved Words'; Unisys COBOL ANSI-85 Programming Reference Manual Volume 1, Basic
368
+ // Implementation, form 8600 1518-307 (February 2003), Appendix B 'Reserved Words'; VSI COBOL
369
+ // Reference Manual, VSI COBOL Version 3.1-7 for OpenVMS, Appendix A 'VSI COBOL for OpenVMS
370
+ // Reserved Words' - Stratus VOS COBOL Language (R010-03), Appendix A 'COBOL Reserved Words' -
371
+ // word source; Stratus VOS COBOL Language (R010-03), 'COBOL Words' - consulted to test whether
372
+ // the COMP-n digits are enumerated anywhere (they are not); Veryant isCOBOL Evolve 2025 R1,
373
+ // Appendices, Appendix A 'isCOBOL Reserved Words' - word source; Veryant isCOBOL 2025 R1
374
+ // Language Reference contents - corroborates hyphen spelling (WORKING-STORAGE, SPECIAL-NAMES,
375
+ // FILE-CONTROL, I-O-CONTROL); Veryant isCOBOL 2025 R1 Language Reference, PERFORM - corroborates
376
+ // hyphen spelling (END-PERFORM); Heirloom Computing, Elastic COBOL Language Reference Manual
377
+ // Appendix (rev. August 2012), Appendix A 'COBOL Reserved Words' and Appendix B 'Elastic COBOL
378
+ // Reserved Words' - word source; Heirloom Computing, Elastic COBOL Language Reference Manual -
379
+ // consulted for a separate intrinsic-function name list; its chapter 15 defines function
380
+ // semantics but publishes no extractable name table; HP COBOL Manual for TNS and TNS/R Programs
381
+ // (HP part number 522555-006), Section 21 'Reserved Words', sub-lists 'All Reserved Words' and
382
+ // 'HP Reserved Words' - word source; Unisys COBOL ANSI-85 Programming Reference Manual Volume 1,
383
+ // Basic Implementation (form 8600 1518-307, Feb 2003), Appendix B 'Reserved Words' - word
384
+ // source; VSI COBOL Reference Manual, VSI COBOL Version 3.1-7 for OpenVMS, Appendix A 'VSI COBOL
385
+ // for OpenVMS Reserved Words' - word source; COBOL-IT Compiler Suite Getting Started v4.1 -
386
+ // PROVENANCE EVIDENCE ONLY, no words taken from it: establishes the OpenCOBOL lineage on which
387
+ // COBOL-IT was excluded; Broadcom TechDocs 'CA Realia II Workbench' bookshelf - GAP EVIDENCE:
388
+ // names the COBOL Reference Guide 3.3 (b009451e.pdf) and 3.2 (b009341e.pdf) whose PDFs sit
389
+ // behind Broadcom OAuth
30
390
 
31
391
  export const RESERVED_WORDS = new Set(`3-D ABORT-TRANSACTION ABSENT ABSTRACT ACCEPT ACCESS ACQUIRE ACTION ACTIVE-CLASS ACTIVE-X ACTUAL ADD
32
392
  ADDRESS ADDRESS-ARRAY ADDRESS-OFFSET ADJUSTABLE-COLUMNS ADVANCE ADVANCING AFP-5A AFTER ALIAS ALIGNED
package/package.json CHANGED
@@ -1,6 +1,6 @@
1
1
  {
2
2
  "name": "@portll/cobolwork",
3
- "version": "0.3.0",
3
+ "version": "0.4.0",
4
4
  "description": "COBOL, JCL and CICS security analysis with zero runtime dependencies: reference-format parser, cross-program data flow, mainframe credential rules. Plugs into commitwork.",
5
5
  "license": "AGPL-3.0-or-later",
6
6
  "author": "Portll <john@portll.net>",
@@ -1522,6 +1522,54 @@
1522
1522
  "idsOnly": true
1523
1523
  }
1524
1524
  },
1525
+ {
1526
+ "kind": "compliance",
1527
+ "ruleId": "input-causes-abend",
1528
+ "framework": "cobit-2019",
1529
+ "clause": "DSS06.02",
1530
+ "rationale": "The rule reports: An input the program accepts ends its run with an abend. That is information processed without the control that keeps it valid, authorised and accurate, which is what this practice asks of business process controls.",
1531
+ "source": {
1532
+ "doc": "cobit2019",
1533
+ "retrieved": "2026-09-20",
1534
+ "idsOnly": true
1535
+ }
1536
+ },
1537
+ {
1538
+ "kind": "compliance",
1539
+ "ruleId": "input-causes-abend-s0c4",
1540
+ "framework": "cobit-2019",
1541
+ "clause": "DSS06.02",
1542
+ "rationale": "The rule reports: An input the program accepts ends its run with a protection exception (S0C4). That is information processed without the control that keeps it valid, authorised and accurate, which is what this practice asks of business process controls.",
1543
+ "source": {
1544
+ "doc": "cobit2019",
1545
+ "retrieved": "2026-09-20",
1546
+ "idsOnly": true
1547
+ }
1548
+ },
1549
+ {
1550
+ "kind": "compliance",
1551
+ "ruleId": "input-causes-abend-s0c7",
1552
+ "framework": "cobit-2019",
1553
+ "clause": "DSS06.02",
1554
+ "rationale": "The rule reports: An input the program accepts ends its run with a data exception (S0C7). That is information processed without the control that keeps it valid, authorised and accurate, which is what this practice asks of business process controls.",
1555
+ "source": {
1556
+ "doc": "cobit2019",
1557
+ "retrieved": "2026-09-20",
1558
+ "idsOnly": true
1559
+ }
1560
+ },
1561
+ {
1562
+ "kind": "compliance",
1563
+ "ruleId": "input-causes-abend-subscript-range",
1564
+ "framework": "cobit-2019",
1565
+ "clause": "DSS06.02",
1566
+ "rationale": "The rule reports: An input the program accepts drives a subscript or reference modification out of range, and the run abends. That is information processed without the control that keeps it valid, authorised and accurate, which is what this practice asks of business process controls.",
1567
+ "source": {
1568
+ "doc": "cobit2019",
1569
+ "retrieved": "2026-09-20",
1570
+ "idsOnly": true
1571
+ }
1572
+ },
1525
1573
  {
1526
1574
  "kind": "compliance",
1527
1575
  "ruleId": "intermediate-result-loses-high-order-digits",