@operato/twin-kernel 0.7.73 → 0.7.74

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
@@ -47,8 +47,19 @@ export interface CurtailableState {
47
47
  curtailable: boolean;
48
48
  minKW?: number;
49
49
  }
50
+ /**
51
+ * 전기 계측 — 전압(V)·전류(A). 전기를 만들거나 쓰는 어떤 설비에서나 같은 모양이다.
52
+ *
53
+ * 발전·저장·개폐 어느 능력에나 붙을 수 있어 따로 둔다. 상별 값은 배열이다(단상이면 원소 하나).
54
+ */
55
+ export interface ElectricalMeasurementState {
56
+ dcVoltage?: number;
57
+ dcCurrent?: number;
58
+ acVoltage?: number[];
59
+ acCurrent?: number[];
60
+ }
50
61
  /** 발전 — 만든다. 역송(`exportKW`)은 소비의 음수가 아니라 별개 사실이다. */
51
- export interface GeneratingState {
62
+ export interface GeneratingState extends ElectricalMeasurementState {
52
63
  generatedKW?: number;
53
64
  exportKW?: number;
54
65
  generatedKWh?: number;
@@ -86,7 +86,7 @@ export const CAPABILITIES = {
86
86
  * 계량 능력(`metered`)이 `kW` 와 `kWh` 를 함께 선언한 것과 같은 짝이다. 적산은 발전 설비의 보편적
87
87
  * 사실이고(태양광·열병합·디젤), 그것이 없으면 성능비·발전시간 같은 성과를 아무도 셀 수 없다.
88
88
  */
89
- stateFields: ['generatedKW', 'exportKW', 'generatedKWh', 'generatedKWhResetAt', 'generatedKWhSince', 'generatedKWhBasis', 'generatedKWhAccumulation', 'generatedKWhLastPeriod', 'generatedKWhLastPeriodEnd', 'generatedKWhLastPeriodObservedFrom', 'generatedKWhLastPeriodObservedTo'], models: ['GeneratingState'], results: ['generated']
89
+ stateFields: ['generatedKW', 'exportKW', 'generatedKWh', 'generatedKWhResetAt', 'generatedKWhSince', 'generatedKWhBasis', 'generatedKWhAccumulation', 'generatedKWhLastPeriod', 'generatedKWhLastPeriodEnd', 'generatedKWhLastPeriodObservedFrom', 'generatedKWhLastPeriodObservedTo', 'dcVoltage', 'dcCurrent', 'acVoltage', 'acCurrent'], models: ['GeneratingState'], results: ['generated']
90
90
  },
91
91
  /*
92
92
  * ── 왜 `storing` 이 아니라 `energyStoring` 인가 (2026-08-15) ────────────────
@@ -1444,6 +1444,14 @@ export interface EquipmentState extends EffectivePeriod {
1444
1444
  */
1445
1445
  generatedKWhLastPeriodObservedFrom?: ISOTime;
1446
1446
  generatedKWhLastPeriodObservedTo?: ISOTime;
1447
+ /**
1448
+ * 전기 계측 — 전압(V)·전류(A). 출력이 0 일 때 **왜 0 인지**를 이 값들이 말한다
1449
+ * (§`EnergyEquipmentData.dcVoltage`).
1450
+ */
1451
+ dcVoltage?: number;
1452
+ dcCurrent?: number;
1453
+ acVoltage?: number[];
1454
+ acCurrent?: number[];
1447
1455
  /** storing — 충전율(%)·충전·방전(kW). 충전과 방전을 나눈다(손실·수명 판단이 그 둘을 구별한다). */
1448
1456
  soc?: number;
1449
1457
  chargeKW?: number;
@@ -2520,6 +2528,30 @@ export interface EnergyEquipmentData {
2520
2528
  curtailable?: boolean;
2521
2529
  minKW?: number;
2522
2530
  position?: 'open' | 'closed' | 'intermediate' | 'bad';
2531
+ /**
2532
+ * **전기 계측** — 전압(V)·전류(A). 전기를 만들거나 쓰는 어떤 설비에서나 같은 모양이다
2533
+ * (IEC 61850 의 계측 항목).
2534
+ *
2535
+ * ── 왜 kW 만으로 부족한가 (2026-08-29) ─────────────────────────────────────
2536
+ * 출력이 0 일 때 **왜 0 인지**를 kW 는 말하지 못한다. 전압과 전류가 있으면 값이 답한다.
2537
+ *
2538
+ * 전압 있음 · 전류 0 회로가 끊겼다 (실측: 직류 621.9V · 0A)
2539
+ * 전압 0 · 전류 0 원천이 없다 (밤·차단)
2540
+ * 전압 낮음 · 전류 높음 부하가 무겁거나 계통이 약하다
2541
+ *
2542
+ * ── 직류와 교류를 가른다 ────────────────────────────────────────────────────
2543
+ * 변환기(인버터·정류기)를 낀 설비는 양쪽이 다른 값이고, 어느 쪽이 죽었는지가 곧 어디가 고장인지다.
2544
+ * 한 이름에 담으면 그 구별이 사라진다.
2545
+ *
2546
+ * ── 상별로 받는다 ──────────────────────────────────────────────────────────
2547
+ * 상 불평형은 그 자체로 사실이고, 합치면 되돌릴 수 없다. 단상이면 원소 하나짜리 배열이다.
2548
+ *
2549
+ * **역률은 이 자리에 없다.** 뜻을 확인하지 못한 값을 받으면 화면이 그것을 역률이라고 말한다.
2550
+ */
2551
+ dcVoltage?: number;
2552
+ dcCurrent?: number;
2553
+ acVoltage?: number[];
2554
+ acCurrent?: number[];
2523
2555
  }
2524
2556
  /**
2525
2557
  * 발전 적산으로 담기는 값 — **발전 설비 하나가 지금까지 만든 양.**
@@ -603,6 +603,11 @@ export class EmsKernel extends FlowEngine {
603
603
  put('curtailable');
604
604
  put('minKW');
605
605
  put('position');
606
+ /* 전기 계측 — 「출력이 0인데 왜 0인가」에 값으로 답하는 축(§`EnergyEquipmentData.dcVoltage`). */
607
+ put('dcVoltage');
608
+ put('dcCurrent');
609
+ put('acVoltage');
610
+ put('acCurrent');
606
611
  /* **값과 함께 시각을 남긴다** — 없으면 화면이 멈춘 값을 지금 값으로 그린다(계량 지점과 같은 규율). */
607
612
  if (d?.at)
608
613
  eq.measuredAt = d.at;
@@ -49,6 +49,11 @@ export interface EnergyEquipmentRecord {
49
49
  curtailable?: boolean;
50
50
  minKW?: number;
51
51
  position?: string;
52
+ /** 전기 계측 — 전압(V)·전류(A). 상별 값은 배열로(단상이면 원소 하나). */
53
+ dcVoltage?: number;
54
+ dcCurrent?: number;
55
+ acVoltage?: number[];
56
+ acCurrent?: number[];
52
57
  }
53
58
  /** 이 레코드가 설비 에너지 상태인가 — 라우팅 판정을 한 곳에 둔다. */
54
59
  export declare function isEnergyEquipmentRecord(record: unknown): boolean;
@@ -180,6 +180,49 @@ export function ingestEnergyEquipmentRecords(records, opts) {
180
180
  else
181
181
  curtailable = r.curtailable;
182
182
  }
183
+ /*
184
+ * ── 전기 계측 (2026-08-29) ─────────────────────────────────────────────────
185
+ *
186
+ * 음수는 받지 않는다. 전압·전류의 크기는 음수가 되지 않고, 방향은 다른 축이 말한다
187
+ * (`chargeKW`·`dischargeKW`·`exportKW`). 음수를 받아 두면 화면이 「-380V」를 그린다.
188
+ *
189
+ * 상별 값은 **배열 그대로** 받는다. 합치거나 평균 내지 않는다 — 상 불평형은 그 자체로 사실이고,
190
+ * 한 수로 접으면 되돌릴 수 없다.
191
+ */
192
+ const dcVoltage = num(r?.dcVoltage, 'dcVoltage', 0);
193
+ const dcCurrent = num(r?.dcCurrent, 'dcCurrent', 0);
194
+ const phases = (raw, name) => {
195
+ if (raw === undefined || raw === null)
196
+ return undefined;
197
+ if (!Array.isArray(raw)) {
198
+ errors.push(`${name} 가 배열이 아니다 — 상별 값이라 배열로 받는다(단상이면 원소 하나): ${JSON.stringify(raw)}`);
199
+ return undefined;
200
+ }
201
+ if (!raw.length) {
202
+ errors.push(`${name} 가 빈 배열이다 — 잰 상이 없으면 그 칸을 보내지 않는다`);
203
+ return undefined;
204
+ }
205
+ const out = [];
206
+ for (const [i, v] of raw.entries()) {
207
+ const n = Number(v);
208
+ if (!Number.isFinite(n)) {
209
+ errors.push(`${name}[${i}] 를 수로 읽을 수 없다: ${JSON.stringify(v)}`);
210
+ return undefined;
211
+ }
212
+ if (n < 0) {
213
+ errors.push(`${name}[${i}] 가 음수다(${n}) — 크기는 음수가 되지 않는다(방향은 다른 축이 말한다)`);
214
+ return undefined;
215
+ }
216
+ out.push(n);
217
+ }
218
+ return out;
219
+ };
220
+ const acVoltage = phases(r?.acVoltage, 'acVoltage');
221
+ const acCurrent = phases(r?.acCurrent, 'acCurrent');
222
+ /* 상 수가 다르면 짝이 맞지 않는다 — 어느 상의 전류인지 알 수 없는 값을 받지 않는다. */
223
+ if (acVoltage && acCurrent && acVoltage.length !== acCurrent.length) {
224
+ errors.push(`acVoltage(${acVoltage.length}상)와 acCurrent(${acCurrent.length}상)의 상 수가 다르다`);
225
+ }
183
226
  let position;
184
227
  if (r?.position !== undefined && r?.position !== null && r?.position !== '') {
185
228
  const p = String(r.position);
@@ -188,7 +231,7 @@ export function ingestEnergyEquipmentRecords(records, opts) {
188
231
  else
189
232
  position = p;
190
233
  }
191
- const values = { generatedKW, exportKW, soc, chargeKW, dischargeKW, curtailable, minKW, position };
234
+ const values = { generatedKW, exportKW, soc, chargeKW, dischargeKW, curtailable, minKW, position, dcVoltage, dcCurrent, acVoltage, acCurrent };
192
235
  if (!errors.length && Object.values(values).every(v => v === undefined)) {
193
236
  errors.push('바꿀 상태가 하나도 없다 — 값 없는 보고는 사실로 적을 것이 없다');
194
237
  }
@@ -207,7 +250,11 @@ export function ingestEnergyEquipmentRecords(records, opts) {
207
250
  ...(dischargeKW !== undefined ? { dischargeKW } : {}),
208
251
  ...(curtailable !== undefined ? { curtailable } : {}),
209
252
  ...(minKW !== undefined ? { minKW } : {}),
210
- ...(position !== undefined ? { position } : {})
253
+ ...(position !== undefined ? { position } : {}),
254
+ ...(dcVoltage !== undefined ? { dcVoltage } : {}),
255
+ ...(dcCurrent !== undefined ? { dcCurrent } : {}),
256
+ ...(acVoltage !== undefined ? { acVoltage } : {}),
257
+ ...(acCurrent !== undefined ? { acCurrent } : {})
211
258
  };
212
259
  accepted.push({
213
260
  eventId: `${opts.tenantId}-energy-eq-${++seq}`,
@@ -2757,7 +2757,7 @@ var CAPABILITIES = {
2757
2757
  * 계량 능력(`metered`)이 `kW` 와 `kWh` 를 함께 선언한 것과 같은 짝이다. 적산은 발전 설비의 보편적
2758
2758
  * 사실이고(태양광·열병합·디젤), 그것이 없으면 성능비·발전시간 같은 성과를 아무도 셀 수 없다.
2759
2759
  */
2760
- stateFields: ["generatedKW", "exportKW", "generatedKWh", "generatedKWhResetAt", "generatedKWhSince", "generatedKWhBasis", "generatedKWhAccumulation", "generatedKWhLastPeriod", "generatedKWhLastPeriodEnd", "generatedKWhLastPeriodObservedFrom", "generatedKWhLastPeriodObservedTo"],
2760
+ stateFields: ["generatedKW", "exportKW", "generatedKWh", "generatedKWhResetAt", "generatedKWhSince", "generatedKWhBasis", "generatedKWhAccumulation", "generatedKWhLastPeriod", "generatedKWhLastPeriodEnd", "generatedKWhLastPeriodObservedFrom", "generatedKWhLastPeriodObservedTo", "dcVoltage", "dcCurrent", "acVoltage", "acCurrent"],
2761
2761
  models: ["GeneratingState"],
2762
2762
  results: ["generated"]
2763
2763
  },
@@ -8178,6 +8178,10 @@ var EmsKernel = class extends FlowEngine {
8178
8178
  put("curtailable");
8179
8179
  put("minKW");
8180
8180
  put("position");
8181
+ put("dcVoltage");
8182
+ put("dcCurrent");
8183
+ put("acVoltage");
8184
+ put("acCurrent");
8181
8185
  if (d?.at) eq.measuredAt = d.at;
8182
8186
  const heardAt = Date.parse(String(d?.at ?? envelope.eventTime ?? ""));
8183
8187
  if (Number.isFinite(heardAt)) this.noteObserved(heardAt);
@@ -9630,13 +9634,45 @@ function ingestEnergyEquipmentRecords(records, opts) {
9630
9634
  if (typeof r.curtailable !== "boolean") errors.push(`curtailable \uAC00 \uCC38/\uAC70\uC9D3\uC774 \uC544\uB2C8\uB2E4: ${JSON.stringify(r.curtailable)}`);
9631
9635
  else curtailable = r.curtailable;
9632
9636
  }
9637
+ const dcVoltage = num(r?.dcVoltage, "dcVoltage", 0);
9638
+ const dcCurrent = num(r?.dcCurrent, "dcCurrent", 0);
9639
+ const phases = (raw, name) => {
9640
+ if (raw === void 0 || raw === null) return void 0;
9641
+ if (!Array.isArray(raw)) {
9642
+ errors.push(`${name} \uAC00 \uBC30\uC5F4\uC774 \uC544\uB2C8\uB2E4 \u2014 \uC0C1\uBCC4 \uAC12\uC774\uB77C \uBC30\uC5F4\uB85C \uBC1B\uB294\uB2E4(\uB2E8\uC0C1\uC774\uBA74 \uC6D0\uC18C \uD558\uB098): ${JSON.stringify(raw)}`);
9643
+ return void 0;
9644
+ }
9645
+ if (!raw.length) {
9646
+ errors.push(`${name} \uAC00 \uBE48 \uBC30\uC5F4\uC774\uB2E4 \u2014 \uC7B0 \uC0C1\uC774 \uC5C6\uC73C\uBA74 \uADF8 \uCE78\uC744 \uBCF4\uB0B4\uC9C0 \uC54A\uB294\uB2E4`);
9647
+ return void 0;
9648
+ }
9649
+ const out = [];
9650
+ for (const [i, v] of raw.entries()) {
9651
+ const n = Number(v);
9652
+ if (!Number.isFinite(n)) {
9653
+ errors.push(`${name}[${i}] \uB97C \uC218\uB85C \uC77D\uC744 \uC218 \uC5C6\uB2E4: ${JSON.stringify(v)}`);
9654
+ return void 0;
9655
+ }
9656
+ if (n < 0) {
9657
+ errors.push(`${name}[${i}] \uAC00 \uC74C\uC218\uB2E4(${n}) \u2014 \uD06C\uAE30\uB294 \uC74C\uC218\uAC00 \uB418\uC9C0 \uC54A\uB294\uB2E4(\uBC29\uD5A5\uC740 \uB2E4\uB978 \uCD95\uC774 \uB9D0\uD55C\uB2E4)`);
9658
+ return void 0;
9659
+ }
9660
+ out.push(n);
9661
+ }
9662
+ return out;
9663
+ };
9664
+ const acVoltage = phases(r?.acVoltage, "acVoltage");
9665
+ const acCurrent = phases(r?.acCurrent, "acCurrent");
9666
+ if (acVoltage && acCurrent && acVoltage.length !== acCurrent.length) {
9667
+ errors.push(`acVoltage(${acVoltage.length}\uC0C1)\uC640 acCurrent(${acCurrent.length}\uC0C1)\uC758 \uC0C1 \uC218\uAC00 \uB2E4\uB974\uB2E4`);
9668
+ }
9633
9669
  let position;
9634
9670
  if (r?.position !== void 0 && r?.position !== null && r?.position !== "") {
9635
9671
  const p = String(r.position);
9636
9672
  if (!POSITIONS.has(p)) errors.push(`position \uC774 \uD45C\uC900 \uAC12\uC774 \uC544\uB2C8\uB2E4(open\xB7closed\xB7intermediate\xB7bad): ${JSON.stringify(r.position)}`);
9637
9673
  else position = p;
9638
9674
  }
9639
- const values = { generatedKW, exportKW, soc, chargeKW, dischargeKW, curtailable, minKW, position };
9675
+ const values = { generatedKW, exportKW, soc, chargeKW, dischargeKW, curtailable, minKW, position, dcVoltage, dcCurrent, acVoltage, acCurrent };
9640
9676
  if (!errors.length && Object.values(values).every((v) => v === void 0)) {
9641
9677
  errors.push("\uBC14\uAFC0 \uC0C1\uD0DC\uAC00 \uD558\uB098\uB3C4 \uC5C6\uB2E4 \u2014 \uAC12 \uC5C6\uB294 \uBCF4\uACE0\uB294 \uC0AC\uC2E4\uB85C \uC801\uC744 \uAC83\uC774 \uC5C6\uB2E4");
9642
9678
  }
@@ -9655,7 +9691,11 @@ function ingestEnergyEquipmentRecords(records, opts) {
9655
9691
  ...dischargeKW !== void 0 ? { dischargeKW } : {},
9656
9692
  ...curtailable !== void 0 ? { curtailable } : {},
9657
9693
  ...minKW !== void 0 ? { minKW } : {},
9658
- ...position !== void 0 ? { position } : {}
9694
+ ...position !== void 0 ? { position } : {},
9695
+ ...dcVoltage !== void 0 ? { dcVoltage } : {},
9696
+ ...dcCurrent !== void 0 ? { dcCurrent } : {},
9697
+ ...acVoltage !== void 0 ? { acVoltage } : {},
9698
+ ...acCurrent !== void 0 ? { acCurrent } : {}
9659
9699
  };
9660
9700
  accepted.push({
9661
9701
  eventId: `${opts.tenantId}-energy-eq-${++seq}`,
package/package.json CHANGED
@@ -1,6 +1,6 @@
1
1
  {
2
2
  "name": "@operato/twin-kernel",
3
- "version": "0.7.73",
3
+ "version": "0.7.74",
4
4
  "type": "module",
5
5
  "description": "Twin Domain Kernel — framework-agnostic, zero-dep (domain + sim + 3-channel contract). WMS/YMS/MES, EPCIS 2.0 · ISA-95.",
6
6
  "publishConfig": {