@oimlsmart/primmel-packages 0.19.0 → 0.20.0
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
|
@@ -0,0 +1,236 @@
|
|
|
1
|
+
# OIML R 129 — test report skeleton (kernel 1.14.0's test_report_skeleton,
|
|
2
|
+
# TODO.roadmap/40): the R 129-4 type evaluation report structure — sections
|
|
3
|
+
# and the form inventory (C140 resolves the entries against the forms
|
|
4
|
+
# register; required/applicability carry the inclusion rules).
|
|
5
|
+
test_report_skeleton r129-3/test-report {
|
|
6
|
+
title "OIML R 129 Type Evaluation Test Report"
|
|
7
|
+
description "The complete test report for an OIML R 129 multi-dimensional measuring instrument type evaluation: administrative information (R 129-3, 0.2–0.6 and R 129-4, 1.4), metrological tests (2.2–2.7), disturbance and climatic tests (2.8–2.12), effect tests (2.13–2.14), examinations and object tests (2.15–2.27), the summary of results (1.1) and the R 129-4 type evaluation checklist."
|
|
8
|
+
section 1 {
|
|
9
|
+
title "Administrative information"
|
|
10
|
+
description "Identification, general information, equipment, configuration, sample selection and adjustments (R 129-3, 0.2–0.6 and R 129-4, 1.4)"
|
|
11
|
+
form r129-3/sec-3.1 {
|
|
12
|
+
file "identification"
|
|
13
|
+
title "Identification"
|
|
14
|
+
required always
|
|
15
|
+
}
|
|
16
|
+
form r129-3/sec-3.2 {
|
|
17
|
+
file "general-info"
|
|
18
|
+
title "General information"
|
|
19
|
+
required always
|
|
20
|
+
}
|
|
21
|
+
form r129-3/sec-3.3 {
|
|
22
|
+
file "equipment-info"
|
|
23
|
+
title "Equipment used"
|
|
24
|
+
required always
|
|
25
|
+
}
|
|
26
|
+
form r129-3/sec-3.4 {
|
|
27
|
+
file "configuration"
|
|
28
|
+
title "Configuration of the instrument"
|
|
29
|
+
required always
|
|
30
|
+
}
|
|
31
|
+
form r129-3/sec-3.5 {
|
|
32
|
+
file "sample-selection"
|
|
33
|
+
title "Sample selection"
|
|
34
|
+
required always
|
|
35
|
+
}
|
|
36
|
+
form r129-3/sec-3.6 {
|
|
37
|
+
file "adjustments-modifications"
|
|
38
|
+
title "Adjustments and modifications"
|
|
39
|
+
required always
|
|
40
|
+
}
|
|
41
|
+
}
|
|
42
|
+
section 2 {
|
|
43
|
+
title "Metrological tests"
|
|
44
|
+
description "Warm-up, repeatability, static temperatures, damp heat and supply-voltage tests (R 129-3, 1.2–1.7)"
|
|
45
|
+
form r129-3/sec-2.2 {
|
|
46
|
+
file "warm-up-time"
|
|
47
|
+
title "Warm-up time test"
|
|
48
|
+
conformance_test /conf/metrological-tests/warm-up-time
|
|
49
|
+
requirements { /req/metrological/mpe /req/technical/warm-up }
|
|
50
|
+
required always
|
|
51
|
+
}
|
|
52
|
+
form r129-3/sec-2.3 {
|
|
53
|
+
file "repeatability"
|
|
54
|
+
title "Repeatability test"
|
|
55
|
+
conformance_test /conf/metrological-tests/repeatability
|
|
56
|
+
requirements { /req/metrological/mpe /req/metrological/calculated-quantities }
|
|
57
|
+
required always
|
|
58
|
+
}
|
|
59
|
+
form r129-3/sec-2.4 {
|
|
60
|
+
file "static-temperatures"
|
|
61
|
+
title "Static temperatures test"
|
|
62
|
+
conformance_test /conf/metrological-tests/static-temperatures
|
|
63
|
+
requirements { /req/metrological/mpe /req/electronic/rated-operating-conditions }
|
|
64
|
+
required always
|
|
65
|
+
}
|
|
66
|
+
form r129-3/sec-2.5.1 {
|
|
67
|
+
file "damp-heat-steady"
|
|
68
|
+
title "Damp heat, steady state test"
|
|
69
|
+
conformance_test /conf/metrological-tests/damp-heat-steady
|
|
70
|
+
requirements { /req/metrological/mpe /req/electronic/rated-operating-conditions }
|
|
71
|
+
required always
|
|
72
|
+
}
|
|
73
|
+
form r129-3/sec-2.6 {
|
|
74
|
+
file "voltage-variation"
|
|
75
|
+
title "AC mains voltage variation test"
|
|
76
|
+
conformance_test /conf/metrological-tests/ac-voltage-variation
|
|
77
|
+
requirements { /req/metrological/mpe /req/electronic/rated-operating-conditions }
|
|
78
|
+
required conditional
|
|
79
|
+
applicability {
|
|
80
|
+
power_supply: [ac-mains]
|
|
81
|
+
}
|
|
82
|
+
}
|
|
83
|
+
form r129-3/sec-2.7 {
|
|
84
|
+
file "low-voltage-battery"
|
|
85
|
+
title "Low voltage of battery test"
|
|
86
|
+
conformance_test /conf/metrological-tests/low-voltage-battery
|
|
87
|
+
requirements { /req/metrological/mpe /req/electronic/rated-operating-conditions }
|
|
88
|
+
required conditional
|
|
89
|
+
applicability {
|
|
90
|
+
power_supply: [battery]
|
|
91
|
+
}
|
|
92
|
+
}
|
|
93
|
+
}
|
|
94
|
+
section 3 {
|
|
95
|
+
title "Disturbance and climatic tests"
|
|
96
|
+
description "Voltage dips, bursts, ESD, surges, RF immunity and cyclic damp heat (R 129-3, 1.8–1.12)"
|
|
97
|
+
form r129-3/sec-2.8 {
|
|
98
|
+
file "voltage-dips"
|
|
99
|
+
title "Voltage dips and short interruptions test"
|
|
100
|
+
conformance_test /conf/disturbance-tests/voltage-dips
|
|
101
|
+
requirements { /req/electronic/disturbance-resistance /req/electronic/no-significant-faults }
|
|
102
|
+
required conditional
|
|
103
|
+
applicability {
|
|
104
|
+
power_supply: [ac-mains]
|
|
105
|
+
}
|
|
106
|
+
}
|
|
107
|
+
form r129-3/sec-2.9 {
|
|
108
|
+
file "bursts"
|
|
109
|
+
title "Electrical fast transient / burst test"
|
|
110
|
+
conformance_test /conf/disturbance-tests/bursts
|
|
111
|
+
requirements { /req/electronic/disturbance-resistance /req/electronic/no-significant-faults }
|
|
112
|
+
required conditional
|
|
113
|
+
applicability {
|
|
114
|
+
power_supply: [ac-mains]
|
|
115
|
+
}
|
|
116
|
+
}
|
|
117
|
+
form r129-3/sec-2.10 {
|
|
118
|
+
file "esd"
|
|
119
|
+
title "Electrostatic discharge test"
|
|
120
|
+
conformance_test /conf/disturbance-tests/esd
|
|
121
|
+
requirements { /req/electronic/disturbance-resistance /req/electronic/no-significant-faults }
|
|
122
|
+
required always
|
|
123
|
+
}
|
|
124
|
+
form r129-3/sec-2.11 {
|
|
125
|
+
file "surge"
|
|
126
|
+
title "Surge immunity test"
|
|
127
|
+
conformance_test /conf/disturbance-tests/surges
|
|
128
|
+
requirements { /req/electronic/disturbance-resistance /req/electronic/no-significant-faults }
|
|
129
|
+
required conditional
|
|
130
|
+
applicability {
|
|
131
|
+
power_supply: [ac-mains]
|
|
132
|
+
}
|
|
133
|
+
}
|
|
134
|
+
form r129-3/sec-2.12.1 {
|
|
135
|
+
file "rf-immunity-radiated"
|
|
136
|
+
title "Radiated RF electromagnetic field immunity test"
|
|
137
|
+
conformance_test /conf/disturbance-tests/rf-immunity-radiated
|
|
138
|
+
requirements { /req/electronic/disturbance-resistance /req/electronic/no-significant-faults }
|
|
139
|
+
required always
|
|
140
|
+
}
|
|
141
|
+
form r129-3/sec-2.12.2 {
|
|
142
|
+
file "rf-immunity-conducted"
|
|
143
|
+
title "Conducted RF disturbance immunity test"
|
|
144
|
+
conformance_test /conf/disturbance-tests/rf-immunity-conducted
|
|
145
|
+
requirements { /req/electronic/disturbance-resistance /req/electronic/no-significant-faults }
|
|
146
|
+
required always
|
|
147
|
+
}
|
|
148
|
+
form r129-3/sec-2.5.2 {
|
|
149
|
+
file "damp-heat-cyclic"
|
|
150
|
+
title "Damp heat, cyclic test"
|
|
151
|
+
conformance_test /conf/disturbance-tests/damp-heat-cyclic
|
|
152
|
+
requirements { /req/metrological/mpe /req/electronic/rated-operating-conditions }
|
|
153
|
+
required always
|
|
154
|
+
}
|
|
155
|
+
}
|
|
156
|
+
section 4 {
|
|
157
|
+
title "Effect tests"
|
|
158
|
+
description "Ambient light and acoustic effects (R 129-3, 1.13–1.14)"
|
|
159
|
+
form r129-3/sec-2.13 {
|
|
160
|
+
file "ambient-light"
|
|
161
|
+
title "Ambient light test"
|
|
162
|
+
conformance_test /conf/effect-tests/ambient-light
|
|
163
|
+
requirements { /req/electronic/light-acoustic-effects }
|
|
164
|
+
required conditional
|
|
165
|
+
applicability {
|
|
166
|
+
measurement_principle: [optical]
|
|
167
|
+
}
|
|
168
|
+
}
|
|
169
|
+
form r129-3/sec-2.14 {
|
|
170
|
+
file "acoustics"
|
|
171
|
+
title "Acoustics test"
|
|
172
|
+
conformance_test /conf/effect-tests/acoustics
|
|
173
|
+
requirements { /req/electronic/light-acoustic-effects }
|
|
174
|
+
required conditional
|
|
175
|
+
applicability {
|
|
176
|
+
measurement_principle: [acoustic]
|
|
177
|
+
}
|
|
178
|
+
}
|
|
179
|
+
}
|
|
180
|
+
section 5 {
|
|
181
|
+
title "Examinations and object tests"
|
|
182
|
+
description "Construction examination and object characteristic tests (R 129-3, 1.15–1.27)"
|
|
183
|
+
form r129-3/sec-2.27 {
|
|
184
|
+
file "construction-examination"
|
|
185
|
+
title "Construction examination"
|
|
186
|
+
conformance_test /conf/examinations/construction-examination
|
|
187
|
+
requirements { /req/technical/suitability-construction /req/technical/suitability-use /req/technical/suitability-verification }
|
|
188
|
+
required always
|
|
189
|
+
}
|
|
190
|
+
form r129-3/sec-2.15 {
|
|
191
|
+
file "object-shape"
|
|
192
|
+
title "Object shape test"
|
|
193
|
+
conformance_test /conf/examinations/object-characteristics
|
|
194
|
+
requirements { /req/object-limitations/object-shape }
|
|
195
|
+
required always
|
|
196
|
+
}
|
|
197
|
+
form r129-3/sec-2.16 {
|
|
198
|
+
file "surface-characteristics"
|
|
199
|
+
title "Surface characteristics tests"
|
|
200
|
+
conformance_test /conf/examinations/object-characteristics
|
|
201
|
+
requirements { /req/object-limitations/surface-colour-uniform /req/object-limitations/surface-colour-non-uniform /req/object-limitations/surface-reflectivity /req/object-limitations/transparency /req/object-limitations/surface-roughness /req/object-limitations/surface-protrusions }
|
|
202
|
+
required always
|
|
203
|
+
}
|
|
204
|
+
form r129-3/sec-2.25 {
|
|
205
|
+
file "orientation-position"
|
|
206
|
+
title "Orientation and position test"
|
|
207
|
+
conformance_test /conf/examinations/object-characteristics
|
|
208
|
+
requirements { /req/object-limitations/orientation-position }
|
|
209
|
+
required always
|
|
210
|
+
}
|
|
211
|
+
form r129-3/sec-2.26 {
|
|
212
|
+
file "speed-movement"
|
|
213
|
+
title "Speed of movement test"
|
|
214
|
+
conformance_test /conf/examinations/object-characteristics
|
|
215
|
+
requirements { /req/object-limitations/speed-movement }
|
|
216
|
+
required conditional
|
|
217
|
+
applicability {
|
|
218
|
+
instrument_category: [automatic]
|
|
219
|
+
}
|
|
220
|
+
}
|
|
221
|
+
}
|
|
222
|
+
section 6 {
|
|
223
|
+
title "Summary and checklist"
|
|
224
|
+
description "Summary of results (R 129-3, 1.1) and the type evaluation checklist (R 129-4, 2)"
|
|
225
|
+
form r129-3/sec-2.1 {
|
|
226
|
+
file "summary-results"
|
|
227
|
+
title "Summary of results"
|
|
228
|
+
required always
|
|
229
|
+
}
|
|
230
|
+
form r129-4/sec-11 {
|
|
231
|
+
file "checklist"
|
|
232
|
+
title "Type evaluation checklist"
|
|
233
|
+
required always
|
|
234
|
+
}
|
|
235
|
+
}
|
|
236
|
+
}
|
|
@@ -0,0 +1,254 @@
|
|
|
1
|
+
# OIML R 144 — test report skeleton (kernel 1.14.0's test_report_skeleton,
|
|
2
|
+
# TODO.roadmap/40): the R 144 type evaluation report structure — sections
|
|
3
|
+
# and the form inventory (C140 resolves the entries against the forms
|
|
4
|
+
# register; required/applicability carry the inclusion rules).
|
|
5
|
+
test_report_skeleton r144-3/test-report {
|
|
6
|
+
title "OIML R 144 Type Evaluation Test Report"
|
|
7
|
+
description "The complete test report for an OIML R 144 gas analytical system type evaluation, structured according to R 144-3: administrative information (3.1–3.6), visual and technical examination (3.7), conclusion of the tests (3.8), general conclusion (3.9) and responsible persons (3.10)."
|
|
8
|
+
section 3.1 {
|
|
9
|
+
title "Administrative"
|
|
10
|
+
description "Laboratory, location, manufacturer, applicant and type identification (R 144-3, 3.1–3.6)"
|
|
11
|
+
form r144-3/sec-3.1 {
|
|
12
|
+
file "03-01-laboratory-info"
|
|
13
|
+
title "Testing Laboratory"
|
|
14
|
+
required always
|
|
15
|
+
}
|
|
16
|
+
form r144-3/sec-3.2 {
|
|
17
|
+
file "03-02-test-location"
|
|
18
|
+
title "Test Location"
|
|
19
|
+
required always
|
|
20
|
+
}
|
|
21
|
+
form r144-3/sec-3.3 {
|
|
22
|
+
file "03-03-manufacturer-info"
|
|
23
|
+
title "Manufacturer"
|
|
24
|
+
required always
|
|
25
|
+
}
|
|
26
|
+
form r144-3/sec-3.4 {
|
|
27
|
+
file "03-04-applicant-info"
|
|
28
|
+
title "Applicant"
|
|
29
|
+
required always
|
|
30
|
+
}
|
|
31
|
+
form r144-3/sec-3.5 {
|
|
32
|
+
file "03-05-type-identification"
|
|
33
|
+
title "Identification of the Type Tested"
|
|
34
|
+
required always
|
|
35
|
+
}
|
|
36
|
+
form r144-3/sec-3.6 {
|
|
37
|
+
file "03-06-type-composition"
|
|
38
|
+
title "Composition of the Type Tested"
|
|
39
|
+
required always
|
|
40
|
+
}
|
|
41
|
+
}
|
|
42
|
+
section 3.2 {
|
|
43
|
+
title "Examinations"
|
|
44
|
+
description "Documentation review (R 144-1, 7.1.1) and visual/technical examination (R 144-3, 3.7)"
|
|
45
|
+
form r144-3/test-documentation-examination {
|
|
46
|
+
file "documentation-examination"
|
|
47
|
+
title "Documentation Examination"
|
|
48
|
+
conformance_test /conf/examinations/documentation
|
|
49
|
+
requirements { /req/technical/type-evaluation-documentation /req/technical/operating-manual }
|
|
50
|
+
required always
|
|
51
|
+
}
|
|
52
|
+
form r144-3/sec-3.7 {
|
|
53
|
+
file "03-07-visual-examination"
|
|
54
|
+
title "Visual and Technical Examination"
|
|
55
|
+
conformance_test /conf/examinations/visual-examination
|
|
56
|
+
required always
|
|
57
|
+
}
|
|
58
|
+
}
|
|
59
|
+
section 3.3 {
|
|
60
|
+
title "Performance Tests"
|
|
61
|
+
description "Metrological performance, influence quantity and disturbance tests (R 144-2, 1.2–1.22) feeding the R 144-3, 3.8 conclusion table"
|
|
62
|
+
form r144-3/test-error-determination {
|
|
63
|
+
file "error-determination"
|
|
64
|
+
title "Error Determination (Intrinsic Error)"
|
|
65
|
+
conformance_test /conf/performance-tests/error-determination
|
|
66
|
+
requirements { /req/metrological/mpe-intrinsic /req/metrological/measuring-range }
|
|
67
|
+
required always
|
|
68
|
+
}
|
|
69
|
+
form r144-3/test-repeatability {
|
|
70
|
+
file "repeatability-test"
|
|
71
|
+
title "Repeatability Test"
|
|
72
|
+
conformance_test /conf/performance-tests/repeatability-test
|
|
73
|
+
requirements { /req/metrological/repeatability }
|
|
74
|
+
required always
|
|
75
|
+
}
|
|
76
|
+
form r144-3/test-drift {
|
|
77
|
+
file "drift-test"
|
|
78
|
+
title "Stability with Time (Drift Test)"
|
|
79
|
+
conformance_test /conf/performance-tests/drift-test
|
|
80
|
+
requirements { /req/metrological/drift }
|
|
81
|
+
required conditional
|
|
82
|
+
applicability {
|
|
83
|
+
adjustment_means: [semi-automatic, automatic]
|
|
84
|
+
}
|
|
85
|
+
}
|
|
86
|
+
form r144-3/test-cross-sensitivity {
|
|
87
|
+
file "cross-sensitivity-test"
|
|
88
|
+
title "Cross Sensitivity Test"
|
|
89
|
+
conformance_test /conf/performance-tests/cross-sensitivity-test
|
|
90
|
+
requirements { /req/metrological/cross-sensitivity }
|
|
91
|
+
required always
|
|
92
|
+
}
|
|
93
|
+
form r144-3/test-dry-heat {
|
|
94
|
+
file "dry-heat-test"
|
|
95
|
+
title "Dry Heat Test"
|
|
96
|
+
conformance_test /conf/performance-tests/dry-heat
|
|
97
|
+
requirements { /req/metrological/rated-conditions /req/metrological/mpe-operating }
|
|
98
|
+
required always
|
|
99
|
+
}
|
|
100
|
+
form r144-3/test-cold {
|
|
101
|
+
file "cold-test"
|
|
102
|
+
title "Cold Test"
|
|
103
|
+
conformance_test /conf/performance-tests/cold
|
|
104
|
+
requirements { /req/metrological/rated-conditions /req/metrological/mpe-operating }
|
|
105
|
+
required always
|
|
106
|
+
}
|
|
107
|
+
form r144-3/test-damp-heat {
|
|
108
|
+
file "damp-heat-test"
|
|
109
|
+
title "Damp Heat Test (Steady State)"
|
|
110
|
+
conformance_test /conf/performance-tests/damp-heat
|
|
111
|
+
requirements { /req/metrological/rated-conditions /req/metrological/mpe-operating }
|
|
112
|
+
required always
|
|
113
|
+
}
|
|
114
|
+
form r144-3/test-ambient-pressure {
|
|
115
|
+
file "ambient-pressure-test"
|
|
116
|
+
title "Ambient Pressure Test"
|
|
117
|
+
conformance_test /conf/performance-tests/ambient-pressure
|
|
118
|
+
requirements { /req/metrological/rated-conditions /req/metrological/mpe-operating }
|
|
119
|
+
required always
|
|
120
|
+
}
|
|
121
|
+
form r144-3/test-power-supply {
|
|
122
|
+
file "power-supply-test"
|
|
123
|
+
title "Power Supply Variation Test"
|
|
124
|
+
conformance_test /conf/performance-tests/power-supply
|
|
125
|
+
requirements { /req/metrological/rated-conditions /req/metrological/mpe-operating }
|
|
126
|
+
required always
|
|
127
|
+
}
|
|
128
|
+
form r144-3/test-vibration {
|
|
129
|
+
file "vibration-test"
|
|
130
|
+
title "Mechanical Vibration Test"
|
|
131
|
+
conformance_test /conf/performance-tests/vibration-test
|
|
132
|
+
requirements { /req/metrological/vibration }
|
|
133
|
+
required always
|
|
134
|
+
}
|
|
135
|
+
form r144-3/test-shock {
|
|
136
|
+
file "shock-test"
|
|
137
|
+
title "Mechanical Shock Test"
|
|
138
|
+
conformance_test /conf/performance-tests/shock-test
|
|
139
|
+
requirements { /req/metrological/disturbances }
|
|
140
|
+
required always
|
|
141
|
+
}
|
|
142
|
+
form r144-3/test-power-reduction {
|
|
143
|
+
file "power-reduction-test"
|
|
144
|
+
title "Short Time Power Reduction Test"
|
|
145
|
+
conformance_test /conf/performance-tests/power-reduction
|
|
146
|
+
requirements { /req/metrological/disturbances }
|
|
147
|
+
required always
|
|
148
|
+
}
|
|
149
|
+
form r144-3/test-bursts-mains {
|
|
150
|
+
file "bursts-mains-test"
|
|
151
|
+
title "Electrical Burst Test (AC/DC Mains)"
|
|
152
|
+
conformance_test /conf/performance-tests/burst-mains
|
|
153
|
+
requirements { /req/metrological/disturbances }
|
|
154
|
+
required always
|
|
155
|
+
}
|
|
156
|
+
form r144-3/test-bursts-signal {
|
|
157
|
+
file "bursts-signal-test"
|
|
158
|
+
title "Electrical Burst Test (Signal, Data and Control Lines)"
|
|
159
|
+
conformance_test /conf/performance-tests/burst-signal
|
|
160
|
+
requirements { /req/metrological/disturbances }
|
|
161
|
+
required conditional
|
|
162
|
+
applicability {
|
|
163
|
+
capabilities: [data-interface]
|
|
164
|
+
}
|
|
165
|
+
}
|
|
166
|
+
form r144-3/test-surge {
|
|
167
|
+
file "surge-test"
|
|
168
|
+
title "Surge Test (Signal, Data and Control Lines)"
|
|
169
|
+
conformance_test /conf/performance-tests/surge
|
|
170
|
+
requirements { /req/metrological/disturbances }
|
|
171
|
+
required conditional
|
|
172
|
+
applicability {
|
|
173
|
+
capabilities: [data-interface]
|
|
174
|
+
}
|
|
175
|
+
}
|
|
176
|
+
form r144-3/test-esd {
|
|
177
|
+
file "esd-test"
|
|
178
|
+
title "Electrostatic Discharge Test"
|
|
179
|
+
conformance_test /conf/performance-tests/esd
|
|
180
|
+
requirements { /req/metrological/disturbances }
|
|
181
|
+
required always
|
|
182
|
+
}
|
|
183
|
+
form r144-3/test-rf-emf {
|
|
184
|
+
file "rf-emf-test"
|
|
185
|
+
title "Radiated RF Electromagnetic Field Test"
|
|
186
|
+
conformance_test /conf/performance-tests/rf-emf
|
|
187
|
+
requirements { /req/metrological/disturbances }
|
|
188
|
+
required always
|
|
189
|
+
}
|
|
190
|
+
form r144-3/test-low-battery {
|
|
191
|
+
file "low-battery-test"
|
|
192
|
+
title "Low Battery Voltage Test"
|
|
193
|
+
conformance_test /conf/performance-tests/low-battery
|
|
194
|
+
requirements { /req/metrological/rated-conditions }
|
|
195
|
+
required conditional
|
|
196
|
+
applicability {
|
|
197
|
+
power_supply: [battery, ac-and-battery]
|
|
198
|
+
}
|
|
199
|
+
}
|
|
200
|
+
form r144-3/test-warm-up-time {
|
|
201
|
+
file "warm-up-time-test"
|
|
202
|
+
title "Warm-up Time Test"
|
|
203
|
+
conformance_test /conf/performance-tests/warm-up-test
|
|
204
|
+
requirements { /req/metrological/warm-up-time }
|
|
205
|
+
required always
|
|
206
|
+
}
|
|
207
|
+
form r144-3/test-response-time {
|
|
208
|
+
file "response-time-test"
|
|
209
|
+
title "Response Time Test"
|
|
210
|
+
conformance_test /conf/performance-tests/response-time-test
|
|
211
|
+
requirements { /req/metrological/response-time }
|
|
212
|
+
required always
|
|
213
|
+
}
|
|
214
|
+
form r144-3/test-flow-spillover {
|
|
215
|
+
file "flow-spillover-test"
|
|
216
|
+
title "Spillover of Gas Flow Rates Test"
|
|
217
|
+
conformance_test /conf/performance-tests/flow-spillover
|
|
218
|
+
requirements { /req/technical/gas-flow-monitoring /req/technical/gas-flow-meter }
|
|
219
|
+
required conditional
|
|
220
|
+
applicability {
|
|
221
|
+
sampling_approach: [extractive]
|
|
222
|
+
}
|
|
223
|
+
}
|
|
224
|
+
form r144-3/test-leakproofness {
|
|
225
|
+
file "leakproofness-test"
|
|
226
|
+
title "Leakproofness Test"
|
|
227
|
+
conformance_test /conf/performance-tests/leakproofness
|
|
228
|
+
requirements { /req/technical/air-tightness }
|
|
229
|
+
required conditional
|
|
230
|
+
applicability {
|
|
231
|
+
sampling_approach: [extractive]
|
|
232
|
+
}
|
|
233
|
+
}
|
|
234
|
+
}
|
|
235
|
+
section 3.4 {
|
|
236
|
+
title "Conclusions"
|
|
237
|
+
description "Conclusion of the tests (3.8), general conclusion (3.9), responsible persons (3.10)"
|
|
238
|
+
form r144-3/sec-3.8 {
|
|
239
|
+
file "03-08-test-conclusions"
|
|
240
|
+
title "Conclusion of the Tests"
|
|
241
|
+
required always
|
|
242
|
+
}
|
|
243
|
+
form r144-3/sec-3.9 {
|
|
244
|
+
file "03-09-general-conclusion"
|
|
245
|
+
title "General Conclusion"
|
|
246
|
+
required always
|
|
247
|
+
}
|
|
248
|
+
form r144-3/sec-3.10 {
|
|
249
|
+
file "03-10-responsible-persons"
|
|
250
|
+
title "Person(s) Responsible for the Testing"
|
|
251
|
+
required always
|
|
252
|
+
}
|
|
253
|
+
}
|
|
254
|
+
}
|
|
@@ -0,0 +1,399 @@
|
|
|
1
|
+
# OIML R 60 — test report skeleton (kernel 1.14.0's test_report_skeleton,
|
|
2
|
+
# TODO.roadmap/40): the R 60-3 type evaluation report structure — sections
|
|
3
|
+
# and the form inventory (C140 resolves the entries against the forms
|
|
4
|
+
# register; required/applicability carry the inclusion rules).
|
|
5
|
+
test_report_skeleton r60-3/test-report {
|
|
6
|
+
title "OIML R 60 Type Evaluation Report"
|
|
7
|
+
description "The complete evaluation report for an OIML R 60 load cell type evaluation, structured according to R 60-3. Contains administrative information, examination results, and performance test data."
|
|
8
|
+
section 4 {
|
|
9
|
+
title "Evaluation Report"
|
|
10
|
+
description "Administrative and descriptive information about the type evaluation"
|
|
11
|
+
form r60-3/sec-4.1 {
|
|
12
|
+
file "04-01-authority-info"
|
|
13
|
+
title "Issuing Authority"
|
|
14
|
+
required always
|
|
15
|
+
}
|
|
16
|
+
form r60-3/sec-4.2 {
|
|
17
|
+
file "04-02-synopsis"
|
|
18
|
+
title "Synopsis of Results"
|
|
19
|
+
required always
|
|
20
|
+
}
|
|
21
|
+
form r60-3/sec-4.3.1 {
|
|
22
|
+
file "04-03-01-examinations"
|
|
23
|
+
title "Summary of Examination Results"
|
|
24
|
+
required always
|
|
25
|
+
}
|
|
26
|
+
form r60-3/sec-4.3.2-a {
|
|
27
|
+
file "04-03-02-a-performance-general"
|
|
28
|
+
title "Summary of Performance Test Results (General)"
|
|
29
|
+
required always
|
|
30
|
+
}
|
|
31
|
+
form r60-3/sec-4.3.2-b {
|
|
32
|
+
file "04-03-02-b-performance-digital"
|
|
33
|
+
title "Summary of Performance Test Results (Digital)"
|
|
34
|
+
required conditional
|
|
35
|
+
applicability {
|
|
36
|
+
technology: [digital, digital-with-processing]
|
|
37
|
+
}
|
|
38
|
+
}
|
|
39
|
+
form r60-3/sec-4.4.1 {
|
|
40
|
+
file "04-04-01-manufacturer"
|
|
41
|
+
title "Manufacturer of the Specimen"
|
|
42
|
+
required always
|
|
43
|
+
}
|
|
44
|
+
form r60-3/sec-4.4.2 {
|
|
45
|
+
file "04-04-02-applicant"
|
|
46
|
+
title "Applicant Information"
|
|
47
|
+
required always
|
|
48
|
+
}
|
|
49
|
+
form r60-3/sec-4.4.3 {
|
|
50
|
+
file "04-04-03-testing-laboratories"
|
|
51
|
+
title "Testing Laboratories"
|
|
52
|
+
required always
|
|
53
|
+
}
|
|
54
|
+
form r60-3/sec-4.5 {
|
|
55
|
+
file "04-05-load-cell-type-info"
|
|
56
|
+
title "Load Cell Type Information"
|
|
57
|
+
required always
|
|
58
|
+
}
|
|
59
|
+
form r60-3/sec-4.6 {
|
|
60
|
+
file "04-06-accessories"
|
|
61
|
+
title "Accessories"
|
|
62
|
+
required always
|
|
63
|
+
}
|
|
64
|
+
form r60-3/sec-4.7 {
|
|
65
|
+
file "04-07-sample-selection"
|
|
66
|
+
title "Selection of Samples and Adjustments (§4.7–4.8)"
|
|
67
|
+
required always
|
|
68
|
+
}
|
|
69
|
+
form r60-3/sec-4.9.1 {
|
|
70
|
+
file "04-09-01-general-info"
|
|
71
|
+
title "Additional Information — General"
|
|
72
|
+
required always
|
|
73
|
+
}
|
|
74
|
+
form r60-3/sec-4.9.2 {
|
|
75
|
+
file "04-09-02-performance-info"
|
|
76
|
+
title "Additional Information — Performance Tests"
|
|
77
|
+
required always
|
|
78
|
+
}
|
|
79
|
+
form r60-3/sec-4.9.3 {
|
|
80
|
+
file "04-09-03-digital-info"
|
|
81
|
+
title "Additional Information — Digital Load Cells"
|
|
82
|
+
required conditional
|
|
83
|
+
applicability {
|
|
84
|
+
technology: [digital, digital-with-processing]
|
|
85
|
+
}
|
|
86
|
+
}
|
|
87
|
+
form r60-3/sec-4.9.4 {
|
|
88
|
+
file "04-09-04-photographs"
|
|
89
|
+
title "Photographs of Examinations and Tests"
|
|
90
|
+
required always
|
|
91
|
+
}
|
|
92
|
+
form r60-3/sec-4.9.5 {
|
|
93
|
+
file "04-09-05-documentation"
|
|
94
|
+
title "Documentation Supplied with the Test Pattern"
|
|
95
|
+
required always
|
|
96
|
+
}
|
|
97
|
+
form r60-3/sec-4.9.6 {
|
|
98
|
+
file "04-09-06-inscriptions"
|
|
99
|
+
title "Inscriptions and Presentations"
|
|
100
|
+
required always
|
|
101
|
+
}
|
|
102
|
+
form r60-3/sec-4.9.7 {
|
|
103
|
+
file "04-09-07-model-range"
|
|
104
|
+
title "Various Designs within the Model Range"
|
|
105
|
+
required always
|
|
106
|
+
}
|
|
107
|
+
form r60-3/sec-4.9.12 {
|
|
108
|
+
file "04-09-12-previous-tests"
|
|
109
|
+
title "Results of Previous Tests Taken into Account"
|
|
110
|
+
required always
|
|
111
|
+
}
|
|
112
|
+
form r60-3/sec-4.10.1 {
|
|
113
|
+
file "04-10-01-force-generating-system"
|
|
114
|
+
title "Test Equipment — Force Generating System"
|
|
115
|
+
required always
|
|
116
|
+
}
|
|
117
|
+
form r60-3/sec-4.10.2 {
|
|
118
|
+
file "04-10-02-weights"
|
|
119
|
+
title "Test Equipment — Weights"
|
|
120
|
+
required always
|
|
121
|
+
}
|
|
122
|
+
form r60-3/sec-4.10.3 {
|
|
123
|
+
file "04-10-03-temperature-chamber"
|
|
124
|
+
title "Test Equipment — Temperature Chamber"
|
|
125
|
+
required always
|
|
126
|
+
}
|
|
127
|
+
form r60-3/sec-4.10.4 {
|
|
128
|
+
file "04-10-04-climate-chamber"
|
|
129
|
+
title "Test Equipment — Climate Chamber"
|
|
130
|
+
required conditional
|
|
131
|
+
applicability {
|
|
132
|
+
humidity_class: [CH, SH]
|
|
133
|
+
}
|
|
134
|
+
}
|
|
135
|
+
form r60-3/sec-4.10.5 {
|
|
136
|
+
file "04-10-05-indicator"
|
|
137
|
+
title "Test Equipment — Indicator"
|
|
138
|
+
required always
|
|
139
|
+
}
|
|
140
|
+
form r60-3/sec-4.10.6 {
|
|
141
|
+
file "04-10-06-terminal"
|
|
142
|
+
title "Test Equipment — Terminal"
|
|
143
|
+
required conditional
|
|
144
|
+
applicability {
|
|
145
|
+
technology: [analogue-active, digital, digital-with-processing]
|
|
146
|
+
}
|
|
147
|
+
}
|
|
148
|
+
form r60-3/sec-4.10.7 {
|
|
149
|
+
file "04-10-07-barometric-pressure-meter"
|
|
150
|
+
title "Test Equipment — Barometric Pressure Meter"
|
|
151
|
+
required always
|
|
152
|
+
}
|
|
153
|
+
form r60-3/sec-4.10.8 {
|
|
154
|
+
file "04-10-08-thermometer"
|
|
155
|
+
title "Test Equipment — Thermometer"
|
|
156
|
+
required always
|
|
157
|
+
}
|
|
158
|
+
form r60-3/sec-4.10.9 {
|
|
159
|
+
file "04-10-09-moisture-analyser"
|
|
160
|
+
title "Test Equipment — Moisture Analyser"
|
|
161
|
+
required conditional
|
|
162
|
+
applicability {
|
|
163
|
+
humidity_class: [CH, SH]
|
|
164
|
+
}
|
|
165
|
+
}
|
|
166
|
+
form r60-3/sec-4.10.10 {
|
|
167
|
+
file "04-10-10-additional-test-equipment"
|
|
168
|
+
title "Test Equipment — Additional Equipment"
|
|
169
|
+
required always
|
|
170
|
+
}
|
|
171
|
+
form r60-3/sec-4.10.11 {
|
|
172
|
+
file "04-10-11-remarks"
|
|
173
|
+
title "Test Equipment — Remarks"
|
|
174
|
+
required always
|
|
175
|
+
}
|
|
176
|
+
form r60-3/form-1 {
|
|
177
|
+
file "test-usage-matrix"
|
|
178
|
+
title "Test Equipment Usage Matrix"
|
|
179
|
+
required always
|
|
180
|
+
}
|
|
181
|
+
}
|
|
182
|
+
section 5 {
|
|
183
|
+
title "Examinations"
|
|
184
|
+
description "Visual and documentation examinations per R 60-2 sections 2.5–2.6"
|
|
185
|
+
form r60-3/sec-5.1 {
|
|
186
|
+
file "marking-examination"
|
|
187
|
+
title "Marking Examination"
|
|
188
|
+
conformance_test /conf/examinations/inscriptions
|
|
189
|
+
requirements { /req/technical/mandatory-markings /req/technical/class-designation /req/technical/load-type-designation /req/technical/temperature-designation /req/technical/humidity-designation /req/technical/nlc-designation }
|
|
190
|
+
required always
|
|
191
|
+
}
|
|
192
|
+
form r60-3/sec-5.2 {
|
|
193
|
+
file "suitability-examination"
|
|
194
|
+
title "Suitability for Testing"
|
|
195
|
+
conformance_test /conf/examinations/suitability
|
|
196
|
+
requirements { /req/technical/mandatory-additional-info }
|
|
197
|
+
required always
|
|
198
|
+
}
|
|
199
|
+
form r60-3/sec-5.3 {
|
|
200
|
+
file "software-examination"
|
|
201
|
+
title "Software Examination"
|
|
202
|
+
conformance_test /conf/examinations/software
|
|
203
|
+
requirements { /req/technical/software }
|
|
204
|
+
required conditional
|
|
205
|
+
applicability {
|
|
206
|
+
technology: [analogue-active, digital]
|
|
207
|
+
}
|
|
208
|
+
}
|
|
209
|
+
form r60-3/sec-5.4 {
|
|
210
|
+
file "documentation-examination"
|
|
211
|
+
title "Documentation Examination"
|
|
212
|
+
conformance_test /conf/examinations/documentation
|
|
213
|
+
requirements { /req/technical/mandatory-additional-info }
|
|
214
|
+
required always
|
|
215
|
+
}
|
|
216
|
+
}
|
|
217
|
+
section 6 {
|
|
218
|
+
title "Performance Tests"
|
|
219
|
+
description "Metrological and environmental performance tests per R 60-2 sections 2.10.1–2.10.7"
|
|
220
|
+
form r60-3/sec-6.1 {
|
|
221
|
+
file "performance-test-summary"
|
|
222
|
+
title "Results of Performance Tests"
|
|
223
|
+
required always
|
|
224
|
+
}
|
|
225
|
+
form r60-3/sec-6.2 {
|
|
226
|
+
file "initial-tests"
|
|
227
|
+
title "Initial Tests and General Notes"
|
|
228
|
+
required always
|
|
229
|
+
}
|
|
230
|
+
subsection "Base Metrological Tests" {
|
|
231
|
+
description "Required for all load cells"
|
|
232
|
+
form r60-3/table-6.3-6.4 {
|
|
233
|
+
file "load-test"
|
|
234
|
+
title "Load Test Data (parameterized: 3 runs for C/D, 5 runs for A/B)"
|
|
235
|
+
conformance_test /conf/metrological-tests/measurement-error-repeatability-mdlo
|
|
236
|
+
requirements { /req/metrological/mpe /req/metrological/repeatability }
|
|
237
|
+
required conditional
|
|
238
|
+
applicability {
|
|
239
|
+
accuracy_class: [A, B, C, D]
|
|
240
|
+
}
|
|
241
|
+
}
|
|
242
|
+
form r60-3/table-6.5 {
|
|
243
|
+
file "load-cell-errors"
|
|
244
|
+
title "Load Cell Errors (E_L)"
|
|
245
|
+
conformance_test /conf/metrological-tests/measurement-error-repeatability-mdlo
|
|
246
|
+
requirements { /req/metrological/mpe }
|
|
247
|
+
required always
|
|
248
|
+
}
|
|
249
|
+
form r60-3/table-6.6 {
|
|
250
|
+
file "repeatability"
|
|
251
|
+
title "Repeatability Errors (E_R)"
|
|
252
|
+
conformance_test /conf/metrological-tests/measurement-error-repeatability-mdlo
|
|
253
|
+
requirements { /req/metrological/repeatability }
|
|
254
|
+
required always
|
|
255
|
+
}
|
|
256
|
+
form r60-3/table-6.7 {
|
|
257
|
+
file "temperature-mdlo"
|
|
258
|
+
title "Temperature Effect on MDLO (C_M)"
|
|
259
|
+
conformance_test /conf/metrological-tests/measurement-error-repeatability-mdlo
|
|
260
|
+
requirements { /req/metrological/temperature-effect-mdlo }
|
|
261
|
+
required always
|
|
262
|
+
}
|
|
263
|
+
form r60-3/table-6.8 {
|
|
264
|
+
file "creep-dr"
|
|
265
|
+
title "Creep (C_C) and DR (C_DR)"
|
|
266
|
+
conformance_test /conf/metrological-tests/creep
|
|
267
|
+
requirements { /req/metrological/creep /req/metrological/creep-20-30 /req/metrological/dr }
|
|
268
|
+
required always
|
|
269
|
+
}
|
|
270
|
+
form r60-3/table-6.9 {
|
|
271
|
+
file "barometric-pressure"
|
|
272
|
+
title "Barometric Pressure Effects (C_P)"
|
|
273
|
+
conformance_test /conf/metrological-tests/barometric-pressure
|
|
274
|
+
requirements { /req/metrological/barometric-pressure }
|
|
275
|
+
required conditional
|
|
276
|
+
notes "May not be necessary depending on the design of the load cell (R 60-3, 2.1.6 footnote) — required unless the manufacturer demonstrates the cell is pressure-insensitive"
|
|
277
|
+
}
|
|
278
|
+
}
|
|
279
|
+
subsection "Humidity Tests" {
|
|
280
|
+
description "Conditional on humidity class designation"
|
|
281
|
+
form r60-3/table-6.10.1 {
|
|
282
|
+
file "humidity-ch"
|
|
283
|
+
title "Humidity Effects CH (Cyclic)"
|
|
284
|
+
conformance_test /conf/metrological-tests/humidity-ch
|
|
285
|
+
requirements { /req/metrological/humidity-ch /req/metrological/mpe }
|
|
286
|
+
required conditional
|
|
287
|
+
applicability {
|
|
288
|
+
humidity_class: [CH]
|
|
289
|
+
}
|
|
290
|
+
}
|
|
291
|
+
form r60-3/table-6.10.2 {
|
|
292
|
+
file "humidity-sh"
|
|
293
|
+
title "Humidity Effects SH (Steady-State)"
|
|
294
|
+
conformance_test /conf/metrological-tests/humidity-sh
|
|
295
|
+
requirements { /req/metrological/humidity-sh }
|
|
296
|
+
required conditional
|
|
297
|
+
applicability {
|
|
298
|
+
humidity_class: [SH]
|
|
299
|
+
}
|
|
300
|
+
}
|
|
301
|
+
}
|
|
302
|
+
subsection "Electronic Load Cell Tests" {
|
|
303
|
+
description "Required for analogue-active and digital load cells only"
|
|
304
|
+
applicability {
|
|
305
|
+
technology: [analogue-active, digital]
|
|
306
|
+
}
|
|
307
|
+
form r60-3/form-6.11 {
|
|
308
|
+
file "warm-up-time"
|
|
309
|
+
title "Warm-Up Time"
|
|
310
|
+
conformance_test /conf/electronic-tests/warm-up-time
|
|
311
|
+
requirements { /req/electronic/warm-up-time }
|
|
312
|
+
required conditional
|
|
313
|
+
applicability {
|
|
314
|
+
technology: [analogue-active, digital]
|
|
315
|
+
}
|
|
316
|
+
}
|
|
317
|
+
form r60-3/form-6.12 {
|
|
318
|
+
file "power-voltage"
|
|
319
|
+
title "Power Voltage Variations"
|
|
320
|
+
conformance_test /conf/electronic-tests/power-voltage
|
|
321
|
+
requirements { /req/electronic/power-voltage-ac /req/electronic/power-voltage-dc /req/electronic/power-voltage-variations }
|
|
322
|
+
required conditional
|
|
323
|
+
applicability {
|
|
324
|
+
technology: [analogue-active, digital]
|
|
325
|
+
}
|
|
326
|
+
}
|
|
327
|
+
form r60-3/form-6.13 {
|
|
328
|
+
file "short-time-power"
|
|
329
|
+
title "Short-Time Power Reductions"
|
|
330
|
+
conformance_test /conf/electronic-tests/short-time-power
|
|
331
|
+
requirements { /req/electronic/disturbances /req/electronic/no-significant-faults }
|
|
332
|
+
required conditional
|
|
333
|
+
applicability {
|
|
334
|
+
technology: [analogue-active, digital]
|
|
335
|
+
}
|
|
336
|
+
}
|
|
337
|
+
form r60-3/form-6.14 {
|
|
338
|
+
file "bursts"
|
|
339
|
+
title "Bursts (EFT)"
|
|
340
|
+
conformance_test /conf/electronic-tests/bursts
|
|
341
|
+
requirements { /req/electronic/disturbances /req/electronic/no-significant-faults }
|
|
342
|
+
required conditional
|
|
343
|
+
applicability {
|
|
344
|
+
technology: [analogue-active, digital]
|
|
345
|
+
}
|
|
346
|
+
}
|
|
347
|
+
form r60-3/form-6.15 {
|
|
348
|
+
file "surge"
|
|
349
|
+
title "Surge"
|
|
350
|
+
conformance_test /conf/electronic-tests/surge
|
|
351
|
+
requirements { /req/electronic/disturbances /req/electronic/no-significant-faults }
|
|
352
|
+
required conditional
|
|
353
|
+
applicability {
|
|
354
|
+
technology: [analogue-active, digital]
|
|
355
|
+
}
|
|
356
|
+
}
|
|
357
|
+
form r60-3/form-6.16 {
|
|
358
|
+
file "esd"
|
|
359
|
+
title "Electrostatic Discharge"
|
|
360
|
+
conformance_test /conf/electronic-tests/esd
|
|
361
|
+
requirements { /req/electronic/disturbances /req/electronic/no-significant-faults }
|
|
362
|
+
required conditional
|
|
363
|
+
applicability {
|
|
364
|
+
technology: [analogue-active, digital]
|
|
365
|
+
}
|
|
366
|
+
}
|
|
367
|
+
form r60-3/form-6.17 {
|
|
368
|
+
file "emc-susceptibility"
|
|
369
|
+
title "Electromagnetic Susceptibility"
|
|
370
|
+
conformance_test /conf/electronic-tests/emc-susceptibility
|
|
371
|
+
requirements { /req/electronic/disturbances /req/electronic/no-significant-faults }
|
|
372
|
+
required conditional
|
|
373
|
+
applicability {
|
|
374
|
+
technology: [analogue-active, digital]
|
|
375
|
+
}
|
|
376
|
+
}
|
|
377
|
+
form r60-3/form-6.18 {
|
|
378
|
+
file "conducted-emc"
|
|
379
|
+
title "Conducted Electromagnetic Fields"
|
|
380
|
+
conformance_test /conf/electronic-tests/conducted-emc
|
|
381
|
+
requirements { /req/electronic/disturbances /req/electronic/no-significant-faults }
|
|
382
|
+
required conditional
|
|
383
|
+
applicability {
|
|
384
|
+
technology: [analogue-active, digital]
|
|
385
|
+
}
|
|
386
|
+
}
|
|
387
|
+
form r60-3/form-6.19 {
|
|
388
|
+
file "span-stability"
|
|
389
|
+
title "Span Stability"
|
|
390
|
+
conformance_test /conf/electronic-tests/span-stability
|
|
391
|
+
requirements { /req/electronic/span-stability }
|
|
392
|
+
required conditional
|
|
393
|
+
applicability {
|
|
394
|
+
accuracy_class: [B, C, D]
|
|
395
|
+
}
|
|
396
|
+
}
|
|
397
|
+
}
|
|
398
|
+
}
|
|
399
|
+
}
|
|
@@ -0,0 +1,426 @@
|
|
|
1
|
+
# OIML R 91 — test report skeleton (kernel 1.14.0's test_report_skeleton,
|
|
2
|
+
# TODO.roadmap/40): the R 91-3:2025 test report format — sections and the
|
|
3
|
+
# form inventory (C140 resolves the entries against the forms register).
|
|
4
|
+
# The R 91-4 type evaluation report is a separate document — its template
|
|
5
|
+
# is the evaluation-report family, not this register.
|
|
6
|
+
test_report_skeleton r91-3/test-report {
|
|
7
|
+
title "OIML R 91-3:2025 — Test report format for speed meters"
|
|
8
|
+
description "The complete test report for an OIML R 91 speed meter evaluation, structured per the R 91-3:2025 report format: the metrological field test, the laboratory programme per R 91-2, and the category-specific tests."
|
|
9
|
+
note "R 91-4 additionally defines the TYPE EVALUATION REPORT format — a separate document from the lab test report (R 91-3); its template is the evaluation-report family, not this register."
|
|
10
|
+
section 01 {
|
|
11
|
+
title "Metrological field test (OIML R 91-2, 4)"
|
|
12
|
+
form r91-3/report-1-1 {
|
|
13
|
+
file "01-01-field-test"
|
|
14
|
+
title "1.1 Traffic condition during measurement (metrological field test)"
|
|
15
|
+
conformance_test /conf/field/stationary-field-test
|
|
16
|
+
requirements { /req/metrological/mpe-stationary /req/metrological/measuring-intervals /req/metrological/indicated-speed /req/category-moving/stationary-mode }
|
|
17
|
+
required always
|
|
18
|
+
}
|
|
19
|
+
form r91-3/report-1-2 {
|
|
20
|
+
file "01-02-statistical-analysis"
|
|
21
|
+
title "1.2 Statistical analysis of errors (optional)"
|
|
22
|
+
conformance_test /conf/field/stationary-field-test
|
|
23
|
+
requirements { /req/metrological/mpe-stationary }
|
|
24
|
+
required conditional
|
|
25
|
+
notes "Optional per R 91-2, 4.7 — the statistical analysis is completed when the field-test error distribution warrants it."
|
|
26
|
+
}
|
|
27
|
+
form r91-3/report-1-3 {
|
|
28
|
+
file "01-03-image-evidence"
|
|
29
|
+
title "1.3 Assignment to image evidence"
|
|
30
|
+
conformance_test /conf/field/stationary-field-test
|
|
31
|
+
requirements { /req/metrological/vehicle-identification }
|
|
32
|
+
required always
|
|
33
|
+
}
|
|
34
|
+
}
|
|
35
|
+
section 02 {
|
|
36
|
+
title "Metrological laboratory tests by traffic simulation (OIML R 91-2, 5)"
|
|
37
|
+
form r91-3/report-2-1 {
|
|
38
|
+
file "02-01-dynamic-performance"
|
|
39
|
+
title "2.1 Dynamic performance test"
|
|
40
|
+
conformance_test /conf/field/dynamic-performance
|
|
41
|
+
requirements { /req/metrological/mpe-stationary /req/metrological/relevant-speed-values }
|
|
42
|
+
required always
|
|
43
|
+
}
|
|
44
|
+
form r91-3/report-2-2 {
|
|
45
|
+
file "02-02-speed-linearity"
|
|
46
|
+
title "2.2 Speed linearity test"
|
|
47
|
+
conformance_test /conf/linearities/speed-linearity
|
|
48
|
+
requirements { /req/metrological/linearity-limit }
|
|
49
|
+
required always
|
|
50
|
+
}
|
|
51
|
+
form r91-3/report-2-3 {
|
|
52
|
+
file "02-03-distance-linearity"
|
|
53
|
+
title "2.3 Distance linearity test"
|
|
54
|
+
conformance_test /conf/linearities/distance-linearity
|
|
55
|
+
requirements { /req/metrological/distance-angle-indication }
|
|
56
|
+
required always
|
|
57
|
+
}
|
|
58
|
+
form r91-3/report-2-4 {
|
|
59
|
+
file "02-04-angle-linearity"
|
|
60
|
+
title "2.4 Angle linearity test"
|
|
61
|
+
conformance_test /conf/linearities/angle-linearity
|
|
62
|
+
requirements { /req/metrological/distance-angle-indication }
|
|
63
|
+
required always
|
|
64
|
+
}
|
|
65
|
+
}
|
|
66
|
+
section 03 {
|
|
67
|
+
title "Influence factor and disturbance tests (OIML R 91-2, 6)"
|
|
68
|
+
form r91-3/report-3-1 {
|
|
69
|
+
file "03-01-dry-heat-operating"
|
|
70
|
+
title "3.1 Dry heat (operating)"
|
|
71
|
+
conformance_test /conf/influence/dry-heat-operating
|
|
72
|
+
requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
|
|
73
|
+
required always
|
|
74
|
+
}
|
|
75
|
+
form r91-3/report-3-2 {
|
|
76
|
+
file "03-02-dry-heat-storage"
|
|
77
|
+
title "3.2 Dry heat (storage)"
|
|
78
|
+
conformance_test /conf/disturbances/dry-heat-storage
|
|
79
|
+
requirements { /req/metrological/disturbances }
|
|
80
|
+
required always
|
|
81
|
+
}
|
|
82
|
+
form r91-3/report-3-3 {
|
|
83
|
+
file "03-03-cold-operating"
|
|
84
|
+
title "3.3 Cold (operating)"
|
|
85
|
+
conformance_test /conf/influence/cold-operating
|
|
86
|
+
requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
|
|
87
|
+
required always
|
|
88
|
+
}
|
|
89
|
+
form r91-3/report-3-4 {
|
|
90
|
+
file "03-04-cold-storage"
|
|
91
|
+
title "3.4 Cold (storage)"
|
|
92
|
+
conformance_test /conf/disturbances/cold-storage
|
|
93
|
+
requirements { /req/metrological/disturbances }
|
|
94
|
+
required always
|
|
95
|
+
}
|
|
96
|
+
form r91-3/report-3-5 {
|
|
97
|
+
file "03-05-damp-heat-cyclic"
|
|
98
|
+
title "3.5 Damp heat, cyclic (condensing)"
|
|
99
|
+
conformance_test /conf/influence/damp-heat-cyclic
|
|
100
|
+
requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
|
|
101
|
+
required always
|
|
102
|
+
}
|
|
103
|
+
form r91-3/report-3-6 {
|
|
104
|
+
file "03-06-water"
|
|
105
|
+
title "3.6 Water (optional)"
|
|
106
|
+
conformance_test /conf/disturbances/water
|
|
107
|
+
requirements { /req/metrological/disturbances }
|
|
108
|
+
required conditional
|
|
109
|
+
notes "Optional test (R 91-2, 6.1 Tables 1-2) — applied when relevant for the declared point of use and installation conditions."
|
|
110
|
+
}
|
|
111
|
+
form r91-3/report-3-7 {
|
|
112
|
+
file "03-07-sand-and-dust"
|
|
113
|
+
title "3.7 Sand and dust (optional)"
|
|
114
|
+
conformance_test /conf/disturbances/sand-and-dust
|
|
115
|
+
requirements { /req/metrological/disturbances }
|
|
116
|
+
required conditional
|
|
117
|
+
notes "Optional test (R 91-2, 6.1 Tables 1-2) — applied when relevant for the declared point of use and installation conditions."
|
|
118
|
+
}
|
|
119
|
+
form r91-3/report-3-8 {
|
|
120
|
+
file "03-08-salt-mist"
|
|
121
|
+
title "3.8 Salt mist (optional)"
|
|
122
|
+
conformance_test /conf/disturbances/salt-mist
|
|
123
|
+
requirements { /req/metrological/disturbances }
|
|
124
|
+
required conditional
|
|
125
|
+
notes "Optional test (R 91-2, 6.1 Table 1, row 6) — applied when relevant for the declared point of use and installation conditions."
|
|
126
|
+
}
|
|
127
|
+
form r91-3/report-3-9 {
|
|
128
|
+
file "03-09-vibration-random"
|
|
129
|
+
title "3.9 Vibration (random)"
|
|
130
|
+
conformance_test /conf/influence/vibration-random
|
|
131
|
+
requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
|
|
132
|
+
required always
|
|
133
|
+
}
|
|
134
|
+
form r91-3/report-3-10 {
|
|
135
|
+
file "03-10-mechanical-shock"
|
|
136
|
+
title "3.10 Mechanical shock"
|
|
137
|
+
conformance_test /conf/disturbances/mechanical-shock
|
|
138
|
+
requirements { /req/metrological/disturbances }
|
|
139
|
+
required always
|
|
140
|
+
}
|
|
141
|
+
form r91-3/report-3-11 {
|
|
142
|
+
file "03-11-dc-mains-voltage-variation"
|
|
143
|
+
title "3.11 DC mains voltage variation"
|
|
144
|
+
conformance_test /conf/influence/dc-mains-voltage-variation
|
|
145
|
+
requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
|
|
146
|
+
required always
|
|
147
|
+
}
|
|
148
|
+
form r91-3/report-3-12 {
|
|
149
|
+
file "03-12-ripple-on-dc-mains"
|
|
150
|
+
title "3.12 Ripple on DC mains power"
|
|
151
|
+
conformance_test /conf/disturbances/ripple-on-dc-mains
|
|
152
|
+
requirements { /req/metrological/disturbances }
|
|
153
|
+
required always
|
|
154
|
+
}
|
|
155
|
+
form r91-3/report-3-13 {
|
|
156
|
+
file "03-13-ac-mains-voltage-variation"
|
|
157
|
+
title "3.13 AC mains voltage variation"
|
|
158
|
+
conformance_test /conf/influence/ac-mains-voltage-variation
|
|
159
|
+
requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
|
|
160
|
+
required always
|
|
161
|
+
}
|
|
162
|
+
form r91-3/report-3-14 {
|
|
163
|
+
file "03-14-ac-mains-frequency-variation"
|
|
164
|
+
title "3.14 AC mains frequency variation"
|
|
165
|
+
conformance_test /conf/influence/ac-mains-frequency-variation
|
|
166
|
+
requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
|
|
167
|
+
required always
|
|
168
|
+
}
|
|
169
|
+
form r91-3/report-3-15 {
|
|
170
|
+
file "03-15-dc-mains-voltage-dips"
|
|
171
|
+
title "3.15 DC mains voltage dips, short interruptions and (short term) voltage variations"
|
|
172
|
+
conformance_test /conf/disturbances/dc-mains-voltage-dips
|
|
173
|
+
requirements { /req/metrological/disturbances }
|
|
174
|
+
required always
|
|
175
|
+
}
|
|
176
|
+
form r91-3/report-3-16 {
|
|
177
|
+
file "03-16-ac-mains-voltage-dips"
|
|
178
|
+
title "3.16 AC mains voltage dips, short interruptions and reductions"
|
|
179
|
+
conformance_test /conf/disturbances/ac-mains-voltage-dips
|
|
180
|
+
requirements { /req/metrological/disturbances }
|
|
181
|
+
required always
|
|
182
|
+
}
|
|
183
|
+
form r91-3/report-3-17 {
|
|
184
|
+
file "03-17-ac-mains-frequency-harmonics"
|
|
185
|
+
title "3.17 AC mains frequency harmonics"
|
|
186
|
+
conformance_test /conf/disturbances/ac-mains-frequency-harmonics
|
|
187
|
+
requirements { /req/metrological/disturbances }
|
|
188
|
+
required always
|
|
189
|
+
}
|
|
190
|
+
form r91-3/report-3-18 {
|
|
191
|
+
file "03-18-vlf-lf-disturbances"
|
|
192
|
+
title "3.18 VLF and LF disturbances on AC and DC mains"
|
|
193
|
+
conformance_test /conf/disturbances/vlf-lf-disturbances-ac-mains
|
|
194
|
+
requirements { /req/metrological/disturbances }
|
|
195
|
+
required always
|
|
196
|
+
}
|
|
197
|
+
form r91-3/report-3-19 {
|
|
198
|
+
file "03-19-bursts-ac-dc-mains"
|
|
199
|
+
title "3.19 Bursts (transients) on AC and DC mains"
|
|
200
|
+
conformance_test /conf/disturbances/bursts-ac-dc-mains
|
|
201
|
+
requirements { /req/metrological/disturbances }
|
|
202
|
+
required always
|
|
203
|
+
}
|
|
204
|
+
form r91-3/report-3-20 {
|
|
205
|
+
file "03-20-surges-ac-dc-mains"
|
|
206
|
+
title "3.20 Surges on AC and DC mains power lines"
|
|
207
|
+
conformance_test /conf/disturbances/surges-ac-dc-mains
|
|
208
|
+
requirements { /req/metrological/disturbances }
|
|
209
|
+
required always
|
|
210
|
+
}
|
|
211
|
+
form r91-3/report-3-21 {
|
|
212
|
+
file "03-21-bursts-signal-lines"
|
|
213
|
+
title "3.21 Bursts (transients) on signal, data and control lines"
|
|
214
|
+
conformance_test /conf/disturbances/bursts-signal-lines
|
|
215
|
+
requirements { /req/metrological/disturbances }
|
|
216
|
+
required always
|
|
217
|
+
}
|
|
218
|
+
form r91-3/report-3-22 {
|
|
219
|
+
file "03-22-surges-signal-lines"
|
|
220
|
+
title "3.22 Surges on signal, data and control lines"
|
|
221
|
+
conformance_test /conf/disturbances/surges-signal-lines
|
|
222
|
+
requirements { /req/metrological/disturbances }
|
|
223
|
+
required always
|
|
224
|
+
}
|
|
225
|
+
form r91-3/report-3-23 {
|
|
226
|
+
file "03-23-ac-mains-magnetic-field"
|
|
227
|
+
title "3.23 AC mains power frequency magnetic field"
|
|
228
|
+
conformance_test /conf/disturbances/ac-mains-power-frequency-magnetic-field
|
|
229
|
+
requirements { /req/metrological/disturbances }
|
|
230
|
+
required always
|
|
231
|
+
}
|
|
232
|
+
form r91-3/report-3-24 {
|
|
233
|
+
file "03-24-conducted-rf-common-mode"
|
|
234
|
+
title "3.24 Conducted (common mode) currents generated by RF electromagnetic fields"
|
|
235
|
+
conformance_test /conf/disturbances/conducted-rf-common-mode-currents
|
|
236
|
+
requirements { /req/metrological/disturbances }
|
|
237
|
+
required always
|
|
238
|
+
}
|
|
239
|
+
form r91-3/report-3-25 {
|
|
240
|
+
file "03-25-rf-electromagnetic-fields"
|
|
241
|
+
title "3.25 RF electromagnetic fields"
|
|
242
|
+
conformance_test /conf/disturbances/rf-electromagnetic-fields
|
|
243
|
+
requirements { /req/metrological/disturbances }
|
|
244
|
+
required always
|
|
245
|
+
}
|
|
246
|
+
form r91-3/report-3-26 {
|
|
247
|
+
file "03-26-electrostatic-discharges"
|
|
248
|
+
title "3.26 Electrostatic discharges"
|
|
249
|
+
conformance_test /conf/disturbances/electrostatic-discharges
|
|
250
|
+
requirements { /req/metrological/disturbances }
|
|
251
|
+
required always
|
|
252
|
+
}
|
|
253
|
+
form r91-3/report-3-27 {
|
|
254
|
+
file "03-27-internal-battery-low-voltage"
|
|
255
|
+
title "3.27 Low voltage of internal battery"
|
|
256
|
+
conformance_test /conf/influence/internal-battery-low-voltage
|
|
257
|
+
requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
|
|
258
|
+
required always
|
|
259
|
+
}
|
|
260
|
+
form r91-3/report-3-28 {
|
|
261
|
+
file "03-28-road-vehicle-battery"
|
|
262
|
+
title "3.28 Voltage variations of a road vehicle battery"
|
|
263
|
+
conformance_test /conf/influence/road-vehicle-battery-voltage-variations
|
|
264
|
+
requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
|
|
265
|
+
required always
|
|
266
|
+
}
|
|
267
|
+
form r91-3/report-3-29 {
|
|
268
|
+
file "03-29-transient-supply-lines"
|
|
269
|
+
title "3.29 Electrical transient conduction along supply lines of external 12 V and 24 V batteries"
|
|
270
|
+
conformance_test /conf/disturbances/transient-conduction-supply-lines
|
|
271
|
+
requirements { /req/metrological/disturbances }
|
|
272
|
+
required always
|
|
273
|
+
}
|
|
274
|
+
form r91-3/report-3-30 {
|
|
275
|
+
file "03-30-transient-other-lines"
|
|
276
|
+
title "3.30 Electrical transient conduction via lines other than supply lines for external 12 V and 24 V batteries"
|
|
277
|
+
conformance_test /conf/disturbances/transient-conduction-other-lines
|
|
278
|
+
requirements { /req/metrological/disturbances }
|
|
279
|
+
required always
|
|
280
|
+
}
|
|
281
|
+
form r91-3/report-3-31 {
|
|
282
|
+
file "03-31-battery-cranking"
|
|
283
|
+
title "3.31 Battery voltage variations during cranking"
|
|
284
|
+
conformance_test /conf/disturbances/battery-voltage-cranking
|
|
285
|
+
requirements { /req/metrological/disturbances }
|
|
286
|
+
required always
|
|
287
|
+
}
|
|
288
|
+
form r91-3/report-3-32 {
|
|
289
|
+
file "03-32-load-dump"
|
|
290
|
+
title "3.32 Load dump test"
|
|
291
|
+
conformance_test /conf/disturbances/load-dump
|
|
292
|
+
requirements { /req/metrological/disturbances }
|
|
293
|
+
required always
|
|
294
|
+
}
|
|
295
|
+
form r91-3/report-3-33 {
|
|
296
|
+
file "03-33-acceleration"
|
|
297
|
+
title "3.33 Acceleration test"
|
|
298
|
+
conformance_test /conf/field/acceleration-test
|
|
299
|
+
requirements { /req/metrological/mpe-stationary }
|
|
300
|
+
required always
|
|
301
|
+
}
|
|
302
|
+
form r91-3/report-3-34 {
|
|
303
|
+
file "03-34-further-influence"
|
|
304
|
+
title "3.34 Further influence quantity tests"
|
|
305
|
+
requirements { /req/metrological/linearity-limit }
|
|
306
|
+
required always
|
|
307
|
+
}
|
|
308
|
+
form r91-3/report-3-35 {
|
|
309
|
+
file "03-35-installation-alignment"
|
|
310
|
+
title "3.35 Installation and alignment of sensor and camera"
|
|
311
|
+
conformance_test /conf/linearities/alignment-misalignment
|
|
312
|
+
requirements { /req/category-across-road/alignment-error }
|
|
313
|
+
required always
|
|
314
|
+
}
|
|
315
|
+
}
|
|
316
|
+
section 04 {
|
|
317
|
+
title "Tests specific to certain categories of speed meters (OIML R 91-2, 7)"
|
|
318
|
+
form r91-3/report-4-1 {
|
|
319
|
+
file "04-01-doppler-radar"
|
|
320
|
+
title "4.1 Doppler-radar based speed meters"
|
|
321
|
+
requirements { /req/category-doppler-radar/beam-width /req/category-doppler-radar/frequency-spectrum /req/category-doppler-radar/spectrum-stability /req/category-doppler-radar/side-lobe }
|
|
322
|
+
required always
|
|
323
|
+
}
|
|
324
|
+
form r91-3/report-4-2 {
|
|
325
|
+
file "04-02-range-finding"
|
|
326
|
+
title "4.2 Range-finding based speed meters"
|
|
327
|
+
requirements { /req/category-range-finding/beam-width /req/category-range-finding/max-distance-viewfinder /req/category-range-finding/pulse-stability /req/category-range-finding/wavelength }
|
|
328
|
+
required always
|
|
329
|
+
}
|
|
330
|
+
form r91-3/report-4-3 {
|
|
331
|
+
file "04-03-average-speed"
|
|
332
|
+
title "4.3 Average speed meters"
|
|
333
|
+
requirements { /req/category-average-speed/detection-field-size /req/category-average-speed/time-synchronisation /req/category-average-speed/image-time-evidence }
|
|
334
|
+
required always
|
|
335
|
+
}
|
|
336
|
+
form r91-3/report-4-4 {
|
|
337
|
+
file "04-04-fixed-distance"
|
|
338
|
+
title "4.4 Fixed-distance speed meters"
|
|
339
|
+
requirements { /req/category-fixed-distance/detection-point-distance /req/category-fixed-distance/redundancy }
|
|
340
|
+
required always
|
|
341
|
+
}
|
|
342
|
+
form r91-3/report-4-5 {
|
|
343
|
+
file "04-05-image-based"
|
|
344
|
+
title "4.5 Image based speed meters"
|
|
345
|
+
conformance_test /conf/category-image-based/image-quality
|
|
346
|
+
requirements { /req/category-image-based/image-quality /req/category-image-based/position-marking /req/category-image-based/position-distances }
|
|
347
|
+
required always
|
|
348
|
+
}
|
|
349
|
+
form r91-3/report-4-6 {
|
|
350
|
+
file "04-06-across-road"
|
|
351
|
+
title "4.6 Across-the-road speed meters"
|
|
352
|
+
conformance_test /conf/examinations/across-road-examination
|
|
353
|
+
requirements { /req/category-across-road/reference-marking /req/category-across-road/cosine-verification }
|
|
354
|
+
required always
|
|
355
|
+
}
|
|
356
|
+
}
|
|
357
|
+
section 05 {
|
|
358
|
+
title "Moving speed meters (OIML R 91-2, 7.7)"
|
|
359
|
+
form r91-3/report-5-1 {
|
|
360
|
+
file "05-01-moving-field-test"
|
|
361
|
+
title "5.1 Moving metrological field test"
|
|
362
|
+
conformance_test /conf/field/moving-field-test
|
|
363
|
+
requirements { /req/category-moving/mpe-moving }
|
|
364
|
+
required always
|
|
365
|
+
}
|
|
366
|
+
form r91-3/report-5-2 {
|
|
367
|
+
file "05-02-ego-field-test"
|
|
368
|
+
title "5.2 Metrological field test of the ego speed meter"
|
|
369
|
+
conformance_test /conf/field/ego-field-test
|
|
370
|
+
requirements { /req/category-moving/ego-speed /req/category-moving/ego-adjustment }
|
|
371
|
+
required always
|
|
372
|
+
}
|
|
373
|
+
form r91-3/report-5-3 {
|
|
374
|
+
file "05-03-moving-traffic-simulation"
|
|
375
|
+
title "5.3 Traffic simulation for moving speed meters"
|
|
376
|
+
requirements { /req/category-moving/mpe-moving /req/category-moving/ego-speed }
|
|
377
|
+
required always
|
|
378
|
+
}
|
|
379
|
+
}
|
|
380
|
+
section 06 {
|
|
381
|
+
title "Software (OIML R 91-2, 8.3)"
|
|
382
|
+
form r91-3/report-6-1 {
|
|
383
|
+
file "06-01-software-general"
|
|
384
|
+
title "6.1 General requirements [mandatory]"
|
|
385
|
+
conformance_test /conf/software/software-examination
|
|
386
|
+
requirements { /req/technical/software }
|
|
387
|
+
required always
|
|
388
|
+
}
|
|
389
|
+
form r91-3/report-6-2 {
|
|
390
|
+
file "06-02-software-protection"
|
|
391
|
+
title "6.2 Software protection [mandatory]"
|
|
392
|
+
conformance_test /conf/software/software-examination
|
|
393
|
+
requirements { /req/technical/software }
|
|
394
|
+
required always
|
|
395
|
+
}
|
|
396
|
+
form r91-3/report-6-3 {
|
|
397
|
+
file "06-03-software-hardware-support"
|
|
398
|
+
title "6.3 Support of hardware features [mandatory]"
|
|
399
|
+
conformance_test /conf/software/software-examination
|
|
400
|
+
requirements { /req/technical/software }
|
|
401
|
+
required always
|
|
402
|
+
}
|
|
403
|
+
form r91-3/report-6-4 {
|
|
404
|
+
file "06-04-software-separation"
|
|
405
|
+
title "6.4 Specification and separation of legally relevant parts and specification of interfaces [optional]"
|
|
406
|
+
conformance_test /conf/software/software-examination
|
|
407
|
+
requirements { /req/technical/software }
|
|
408
|
+
required always
|
|
409
|
+
}
|
|
410
|
+
form r91-3/report-6-5 {
|
|
411
|
+
file "06-05-software-maintenance"
|
|
412
|
+
title "6.5 Maintenance and re-configuration [optional]"
|
|
413
|
+
conformance_test /conf/software/software-examination
|
|
414
|
+
requirements { /req/technical/software }
|
|
415
|
+
required always
|
|
416
|
+
}
|
|
417
|
+
}
|
|
418
|
+
section 07 {
|
|
419
|
+
title "General remarks"
|
|
420
|
+
form r91-3/report-general-remarks {
|
|
421
|
+
file "07-general-remarks"
|
|
422
|
+
title "General remarks"
|
|
423
|
+
required always
|
|
424
|
+
}
|
|
425
|
+
}
|
|
426
|
+
}
|
package/package.json
CHANGED
|
@@ -1,6 +1,6 @@
|
|
|
1
1
|
{
|
|
2
2
|
"name": "@oimlsmart/primmel-packages",
|
|
3
|
-
"version": "0.
|
|
3
|
+
"version": "0.20.0",
|
|
4
4
|
"description": "The OIML SMART platform's authoritative model content: every Recommendation, the OIML-CS scheme, the CASCO foundations, the shared modules, and the product/program reference packages as Primmel (.prl) packages — the single source of truth the platform's data trees regenerate from. Consumed by the smart monorepo (oimlsmart/smart) at a pinned version (TODO.repos/02).",
|
|
5
5
|
"type": "module",
|
|
6
6
|
"repository": {
|