@oimlsmart/primmel-packages 0.19.0 → 0.20.0

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
@@ -0,0 +1,236 @@
1
+ # OIML R 129 — test report skeleton (kernel 1.14.0's test_report_skeleton,
2
+ # TODO.roadmap/40): the R 129-4 type evaluation report structure — sections
3
+ # and the form inventory (C140 resolves the entries against the forms
4
+ # register; required/applicability carry the inclusion rules).
5
+ test_report_skeleton r129-3/test-report {
6
+ title "OIML R 129 Type Evaluation Test Report"
7
+ description "The complete test report for an OIML R 129 multi-dimensional measuring instrument type evaluation: administrative information (R 129-3, 0.2–0.6 and R 129-4, 1.4), metrological tests (2.2–2.7), disturbance and climatic tests (2.8–2.12), effect tests (2.13–2.14), examinations and object tests (2.15–2.27), the summary of results (1.1) and the R 129-4 type evaluation checklist."
8
+ section 1 {
9
+ title "Administrative information"
10
+ description "Identification, general information, equipment, configuration, sample selection and adjustments (R 129-3, 0.2–0.6 and R 129-4, 1.4)"
11
+ form r129-3/sec-3.1 {
12
+ file "identification"
13
+ title "Identification"
14
+ required always
15
+ }
16
+ form r129-3/sec-3.2 {
17
+ file "general-info"
18
+ title "General information"
19
+ required always
20
+ }
21
+ form r129-3/sec-3.3 {
22
+ file "equipment-info"
23
+ title "Equipment used"
24
+ required always
25
+ }
26
+ form r129-3/sec-3.4 {
27
+ file "configuration"
28
+ title "Configuration of the instrument"
29
+ required always
30
+ }
31
+ form r129-3/sec-3.5 {
32
+ file "sample-selection"
33
+ title "Sample selection"
34
+ required always
35
+ }
36
+ form r129-3/sec-3.6 {
37
+ file "adjustments-modifications"
38
+ title "Adjustments and modifications"
39
+ required always
40
+ }
41
+ }
42
+ section 2 {
43
+ title "Metrological tests"
44
+ description "Warm-up, repeatability, static temperatures, damp heat and supply-voltage tests (R 129-3, 1.2–1.7)"
45
+ form r129-3/sec-2.2 {
46
+ file "warm-up-time"
47
+ title "Warm-up time test"
48
+ conformance_test /conf/metrological-tests/warm-up-time
49
+ requirements { /req/metrological/mpe /req/technical/warm-up }
50
+ required always
51
+ }
52
+ form r129-3/sec-2.3 {
53
+ file "repeatability"
54
+ title "Repeatability test"
55
+ conformance_test /conf/metrological-tests/repeatability
56
+ requirements { /req/metrological/mpe /req/metrological/calculated-quantities }
57
+ required always
58
+ }
59
+ form r129-3/sec-2.4 {
60
+ file "static-temperatures"
61
+ title "Static temperatures test"
62
+ conformance_test /conf/metrological-tests/static-temperatures
63
+ requirements { /req/metrological/mpe /req/electronic/rated-operating-conditions }
64
+ required always
65
+ }
66
+ form r129-3/sec-2.5.1 {
67
+ file "damp-heat-steady"
68
+ title "Damp heat, steady state test"
69
+ conformance_test /conf/metrological-tests/damp-heat-steady
70
+ requirements { /req/metrological/mpe /req/electronic/rated-operating-conditions }
71
+ required always
72
+ }
73
+ form r129-3/sec-2.6 {
74
+ file "voltage-variation"
75
+ title "AC mains voltage variation test"
76
+ conformance_test /conf/metrological-tests/ac-voltage-variation
77
+ requirements { /req/metrological/mpe /req/electronic/rated-operating-conditions }
78
+ required conditional
79
+ applicability {
80
+ power_supply: [ac-mains]
81
+ }
82
+ }
83
+ form r129-3/sec-2.7 {
84
+ file "low-voltage-battery"
85
+ title "Low voltage of battery test"
86
+ conformance_test /conf/metrological-tests/low-voltage-battery
87
+ requirements { /req/metrological/mpe /req/electronic/rated-operating-conditions }
88
+ required conditional
89
+ applicability {
90
+ power_supply: [battery]
91
+ }
92
+ }
93
+ }
94
+ section 3 {
95
+ title "Disturbance and climatic tests"
96
+ description "Voltage dips, bursts, ESD, surges, RF immunity and cyclic damp heat (R 129-3, 1.8–1.12)"
97
+ form r129-3/sec-2.8 {
98
+ file "voltage-dips"
99
+ title "Voltage dips and short interruptions test"
100
+ conformance_test /conf/disturbance-tests/voltage-dips
101
+ requirements { /req/electronic/disturbance-resistance /req/electronic/no-significant-faults }
102
+ required conditional
103
+ applicability {
104
+ power_supply: [ac-mains]
105
+ }
106
+ }
107
+ form r129-3/sec-2.9 {
108
+ file "bursts"
109
+ title "Electrical fast transient / burst test"
110
+ conformance_test /conf/disturbance-tests/bursts
111
+ requirements { /req/electronic/disturbance-resistance /req/electronic/no-significant-faults }
112
+ required conditional
113
+ applicability {
114
+ power_supply: [ac-mains]
115
+ }
116
+ }
117
+ form r129-3/sec-2.10 {
118
+ file "esd"
119
+ title "Electrostatic discharge test"
120
+ conformance_test /conf/disturbance-tests/esd
121
+ requirements { /req/electronic/disturbance-resistance /req/electronic/no-significant-faults }
122
+ required always
123
+ }
124
+ form r129-3/sec-2.11 {
125
+ file "surge"
126
+ title "Surge immunity test"
127
+ conformance_test /conf/disturbance-tests/surges
128
+ requirements { /req/electronic/disturbance-resistance /req/electronic/no-significant-faults }
129
+ required conditional
130
+ applicability {
131
+ power_supply: [ac-mains]
132
+ }
133
+ }
134
+ form r129-3/sec-2.12.1 {
135
+ file "rf-immunity-radiated"
136
+ title "Radiated RF electromagnetic field immunity test"
137
+ conformance_test /conf/disturbance-tests/rf-immunity-radiated
138
+ requirements { /req/electronic/disturbance-resistance /req/electronic/no-significant-faults }
139
+ required always
140
+ }
141
+ form r129-3/sec-2.12.2 {
142
+ file "rf-immunity-conducted"
143
+ title "Conducted RF disturbance immunity test"
144
+ conformance_test /conf/disturbance-tests/rf-immunity-conducted
145
+ requirements { /req/electronic/disturbance-resistance /req/electronic/no-significant-faults }
146
+ required always
147
+ }
148
+ form r129-3/sec-2.5.2 {
149
+ file "damp-heat-cyclic"
150
+ title "Damp heat, cyclic test"
151
+ conformance_test /conf/disturbance-tests/damp-heat-cyclic
152
+ requirements { /req/metrological/mpe /req/electronic/rated-operating-conditions }
153
+ required always
154
+ }
155
+ }
156
+ section 4 {
157
+ title "Effect tests"
158
+ description "Ambient light and acoustic effects (R 129-3, 1.13–1.14)"
159
+ form r129-3/sec-2.13 {
160
+ file "ambient-light"
161
+ title "Ambient light test"
162
+ conformance_test /conf/effect-tests/ambient-light
163
+ requirements { /req/electronic/light-acoustic-effects }
164
+ required conditional
165
+ applicability {
166
+ measurement_principle: [optical]
167
+ }
168
+ }
169
+ form r129-3/sec-2.14 {
170
+ file "acoustics"
171
+ title "Acoustics test"
172
+ conformance_test /conf/effect-tests/acoustics
173
+ requirements { /req/electronic/light-acoustic-effects }
174
+ required conditional
175
+ applicability {
176
+ measurement_principle: [acoustic]
177
+ }
178
+ }
179
+ }
180
+ section 5 {
181
+ title "Examinations and object tests"
182
+ description "Construction examination and object characteristic tests (R 129-3, 1.15–1.27)"
183
+ form r129-3/sec-2.27 {
184
+ file "construction-examination"
185
+ title "Construction examination"
186
+ conformance_test /conf/examinations/construction-examination
187
+ requirements { /req/technical/suitability-construction /req/technical/suitability-use /req/technical/suitability-verification }
188
+ required always
189
+ }
190
+ form r129-3/sec-2.15 {
191
+ file "object-shape"
192
+ title "Object shape test"
193
+ conformance_test /conf/examinations/object-characteristics
194
+ requirements { /req/object-limitations/object-shape }
195
+ required always
196
+ }
197
+ form r129-3/sec-2.16 {
198
+ file "surface-characteristics"
199
+ title "Surface characteristics tests"
200
+ conformance_test /conf/examinations/object-characteristics
201
+ requirements { /req/object-limitations/surface-colour-uniform /req/object-limitations/surface-colour-non-uniform /req/object-limitations/surface-reflectivity /req/object-limitations/transparency /req/object-limitations/surface-roughness /req/object-limitations/surface-protrusions }
202
+ required always
203
+ }
204
+ form r129-3/sec-2.25 {
205
+ file "orientation-position"
206
+ title "Orientation and position test"
207
+ conformance_test /conf/examinations/object-characteristics
208
+ requirements { /req/object-limitations/orientation-position }
209
+ required always
210
+ }
211
+ form r129-3/sec-2.26 {
212
+ file "speed-movement"
213
+ title "Speed of movement test"
214
+ conformance_test /conf/examinations/object-characteristics
215
+ requirements { /req/object-limitations/speed-movement }
216
+ required conditional
217
+ applicability {
218
+ instrument_category: [automatic]
219
+ }
220
+ }
221
+ }
222
+ section 6 {
223
+ title "Summary and checklist"
224
+ description "Summary of results (R 129-3, 1.1) and the type evaluation checklist (R 129-4, 2)"
225
+ form r129-3/sec-2.1 {
226
+ file "summary-results"
227
+ title "Summary of results"
228
+ required always
229
+ }
230
+ form r129-4/sec-11 {
231
+ file "checklist"
232
+ title "Type evaluation checklist"
233
+ required always
234
+ }
235
+ }
236
+ }
@@ -0,0 +1,254 @@
1
+ # OIML R 144 — test report skeleton (kernel 1.14.0's test_report_skeleton,
2
+ # TODO.roadmap/40): the R 144 type evaluation report structure — sections
3
+ # and the form inventory (C140 resolves the entries against the forms
4
+ # register; required/applicability carry the inclusion rules).
5
+ test_report_skeleton r144-3/test-report {
6
+ title "OIML R 144 Type Evaluation Test Report"
7
+ description "The complete test report for an OIML R 144 gas analytical system type evaluation, structured according to R 144-3: administrative information (3.1–3.6), visual and technical examination (3.7), conclusion of the tests (3.8), general conclusion (3.9) and responsible persons (3.10)."
8
+ section 3.1 {
9
+ title "Administrative"
10
+ description "Laboratory, location, manufacturer, applicant and type identification (R 144-3, 3.1–3.6)"
11
+ form r144-3/sec-3.1 {
12
+ file "03-01-laboratory-info"
13
+ title "Testing Laboratory"
14
+ required always
15
+ }
16
+ form r144-3/sec-3.2 {
17
+ file "03-02-test-location"
18
+ title "Test Location"
19
+ required always
20
+ }
21
+ form r144-3/sec-3.3 {
22
+ file "03-03-manufacturer-info"
23
+ title "Manufacturer"
24
+ required always
25
+ }
26
+ form r144-3/sec-3.4 {
27
+ file "03-04-applicant-info"
28
+ title "Applicant"
29
+ required always
30
+ }
31
+ form r144-3/sec-3.5 {
32
+ file "03-05-type-identification"
33
+ title "Identification of the Type Tested"
34
+ required always
35
+ }
36
+ form r144-3/sec-3.6 {
37
+ file "03-06-type-composition"
38
+ title "Composition of the Type Tested"
39
+ required always
40
+ }
41
+ }
42
+ section 3.2 {
43
+ title "Examinations"
44
+ description "Documentation review (R 144-1, 7.1.1) and visual/technical examination (R 144-3, 3.7)"
45
+ form r144-3/test-documentation-examination {
46
+ file "documentation-examination"
47
+ title "Documentation Examination"
48
+ conformance_test /conf/examinations/documentation
49
+ requirements { /req/technical/type-evaluation-documentation /req/technical/operating-manual }
50
+ required always
51
+ }
52
+ form r144-3/sec-3.7 {
53
+ file "03-07-visual-examination"
54
+ title "Visual and Technical Examination"
55
+ conformance_test /conf/examinations/visual-examination
56
+ required always
57
+ }
58
+ }
59
+ section 3.3 {
60
+ title "Performance Tests"
61
+ description "Metrological performance, influence quantity and disturbance tests (R 144-2, 1.2–1.22) feeding the R 144-3, 3.8 conclusion table"
62
+ form r144-3/test-error-determination {
63
+ file "error-determination"
64
+ title "Error Determination (Intrinsic Error)"
65
+ conformance_test /conf/performance-tests/error-determination
66
+ requirements { /req/metrological/mpe-intrinsic /req/metrological/measuring-range }
67
+ required always
68
+ }
69
+ form r144-3/test-repeatability {
70
+ file "repeatability-test"
71
+ title "Repeatability Test"
72
+ conformance_test /conf/performance-tests/repeatability-test
73
+ requirements { /req/metrological/repeatability }
74
+ required always
75
+ }
76
+ form r144-3/test-drift {
77
+ file "drift-test"
78
+ title "Stability with Time (Drift Test)"
79
+ conformance_test /conf/performance-tests/drift-test
80
+ requirements { /req/metrological/drift }
81
+ required conditional
82
+ applicability {
83
+ adjustment_means: [semi-automatic, automatic]
84
+ }
85
+ }
86
+ form r144-3/test-cross-sensitivity {
87
+ file "cross-sensitivity-test"
88
+ title "Cross Sensitivity Test"
89
+ conformance_test /conf/performance-tests/cross-sensitivity-test
90
+ requirements { /req/metrological/cross-sensitivity }
91
+ required always
92
+ }
93
+ form r144-3/test-dry-heat {
94
+ file "dry-heat-test"
95
+ title "Dry Heat Test"
96
+ conformance_test /conf/performance-tests/dry-heat
97
+ requirements { /req/metrological/rated-conditions /req/metrological/mpe-operating }
98
+ required always
99
+ }
100
+ form r144-3/test-cold {
101
+ file "cold-test"
102
+ title "Cold Test"
103
+ conformance_test /conf/performance-tests/cold
104
+ requirements { /req/metrological/rated-conditions /req/metrological/mpe-operating }
105
+ required always
106
+ }
107
+ form r144-3/test-damp-heat {
108
+ file "damp-heat-test"
109
+ title "Damp Heat Test (Steady State)"
110
+ conformance_test /conf/performance-tests/damp-heat
111
+ requirements { /req/metrological/rated-conditions /req/metrological/mpe-operating }
112
+ required always
113
+ }
114
+ form r144-3/test-ambient-pressure {
115
+ file "ambient-pressure-test"
116
+ title "Ambient Pressure Test"
117
+ conformance_test /conf/performance-tests/ambient-pressure
118
+ requirements { /req/metrological/rated-conditions /req/metrological/mpe-operating }
119
+ required always
120
+ }
121
+ form r144-3/test-power-supply {
122
+ file "power-supply-test"
123
+ title "Power Supply Variation Test"
124
+ conformance_test /conf/performance-tests/power-supply
125
+ requirements { /req/metrological/rated-conditions /req/metrological/mpe-operating }
126
+ required always
127
+ }
128
+ form r144-3/test-vibration {
129
+ file "vibration-test"
130
+ title "Mechanical Vibration Test"
131
+ conformance_test /conf/performance-tests/vibration-test
132
+ requirements { /req/metrological/vibration }
133
+ required always
134
+ }
135
+ form r144-3/test-shock {
136
+ file "shock-test"
137
+ title "Mechanical Shock Test"
138
+ conformance_test /conf/performance-tests/shock-test
139
+ requirements { /req/metrological/disturbances }
140
+ required always
141
+ }
142
+ form r144-3/test-power-reduction {
143
+ file "power-reduction-test"
144
+ title "Short Time Power Reduction Test"
145
+ conformance_test /conf/performance-tests/power-reduction
146
+ requirements { /req/metrological/disturbances }
147
+ required always
148
+ }
149
+ form r144-3/test-bursts-mains {
150
+ file "bursts-mains-test"
151
+ title "Electrical Burst Test (AC/DC Mains)"
152
+ conformance_test /conf/performance-tests/burst-mains
153
+ requirements { /req/metrological/disturbances }
154
+ required always
155
+ }
156
+ form r144-3/test-bursts-signal {
157
+ file "bursts-signal-test"
158
+ title "Electrical Burst Test (Signal, Data and Control Lines)"
159
+ conformance_test /conf/performance-tests/burst-signal
160
+ requirements { /req/metrological/disturbances }
161
+ required conditional
162
+ applicability {
163
+ capabilities: [data-interface]
164
+ }
165
+ }
166
+ form r144-3/test-surge {
167
+ file "surge-test"
168
+ title "Surge Test (Signal, Data and Control Lines)"
169
+ conformance_test /conf/performance-tests/surge
170
+ requirements { /req/metrological/disturbances }
171
+ required conditional
172
+ applicability {
173
+ capabilities: [data-interface]
174
+ }
175
+ }
176
+ form r144-3/test-esd {
177
+ file "esd-test"
178
+ title "Electrostatic Discharge Test"
179
+ conformance_test /conf/performance-tests/esd
180
+ requirements { /req/metrological/disturbances }
181
+ required always
182
+ }
183
+ form r144-3/test-rf-emf {
184
+ file "rf-emf-test"
185
+ title "Radiated RF Electromagnetic Field Test"
186
+ conformance_test /conf/performance-tests/rf-emf
187
+ requirements { /req/metrological/disturbances }
188
+ required always
189
+ }
190
+ form r144-3/test-low-battery {
191
+ file "low-battery-test"
192
+ title "Low Battery Voltage Test"
193
+ conformance_test /conf/performance-tests/low-battery
194
+ requirements { /req/metrological/rated-conditions }
195
+ required conditional
196
+ applicability {
197
+ power_supply: [battery, ac-and-battery]
198
+ }
199
+ }
200
+ form r144-3/test-warm-up-time {
201
+ file "warm-up-time-test"
202
+ title "Warm-up Time Test"
203
+ conformance_test /conf/performance-tests/warm-up-test
204
+ requirements { /req/metrological/warm-up-time }
205
+ required always
206
+ }
207
+ form r144-3/test-response-time {
208
+ file "response-time-test"
209
+ title "Response Time Test"
210
+ conformance_test /conf/performance-tests/response-time-test
211
+ requirements { /req/metrological/response-time }
212
+ required always
213
+ }
214
+ form r144-3/test-flow-spillover {
215
+ file "flow-spillover-test"
216
+ title "Spillover of Gas Flow Rates Test"
217
+ conformance_test /conf/performance-tests/flow-spillover
218
+ requirements { /req/technical/gas-flow-monitoring /req/technical/gas-flow-meter }
219
+ required conditional
220
+ applicability {
221
+ sampling_approach: [extractive]
222
+ }
223
+ }
224
+ form r144-3/test-leakproofness {
225
+ file "leakproofness-test"
226
+ title "Leakproofness Test"
227
+ conformance_test /conf/performance-tests/leakproofness
228
+ requirements { /req/technical/air-tightness }
229
+ required conditional
230
+ applicability {
231
+ sampling_approach: [extractive]
232
+ }
233
+ }
234
+ }
235
+ section 3.4 {
236
+ title "Conclusions"
237
+ description "Conclusion of the tests (3.8), general conclusion (3.9), responsible persons (3.10)"
238
+ form r144-3/sec-3.8 {
239
+ file "03-08-test-conclusions"
240
+ title "Conclusion of the Tests"
241
+ required always
242
+ }
243
+ form r144-3/sec-3.9 {
244
+ file "03-09-general-conclusion"
245
+ title "General Conclusion"
246
+ required always
247
+ }
248
+ form r144-3/sec-3.10 {
249
+ file "03-10-responsible-persons"
250
+ title "Person(s) Responsible for the Testing"
251
+ required always
252
+ }
253
+ }
254
+ }
@@ -0,0 +1,399 @@
1
+ # OIML R 60 — test report skeleton (kernel 1.14.0's test_report_skeleton,
2
+ # TODO.roadmap/40): the R 60-3 type evaluation report structure — sections
3
+ # and the form inventory (C140 resolves the entries against the forms
4
+ # register; required/applicability carry the inclusion rules).
5
+ test_report_skeleton r60-3/test-report {
6
+ title "OIML R 60 Type Evaluation Report"
7
+ description "The complete evaluation report for an OIML R 60 load cell type evaluation, structured according to R 60-3. Contains administrative information, examination results, and performance test data."
8
+ section 4 {
9
+ title "Evaluation Report"
10
+ description "Administrative and descriptive information about the type evaluation"
11
+ form r60-3/sec-4.1 {
12
+ file "04-01-authority-info"
13
+ title "Issuing Authority"
14
+ required always
15
+ }
16
+ form r60-3/sec-4.2 {
17
+ file "04-02-synopsis"
18
+ title "Synopsis of Results"
19
+ required always
20
+ }
21
+ form r60-3/sec-4.3.1 {
22
+ file "04-03-01-examinations"
23
+ title "Summary of Examination Results"
24
+ required always
25
+ }
26
+ form r60-3/sec-4.3.2-a {
27
+ file "04-03-02-a-performance-general"
28
+ title "Summary of Performance Test Results (General)"
29
+ required always
30
+ }
31
+ form r60-3/sec-4.3.2-b {
32
+ file "04-03-02-b-performance-digital"
33
+ title "Summary of Performance Test Results (Digital)"
34
+ required conditional
35
+ applicability {
36
+ technology: [digital, digital-with-processing]
37
+ }
38
+ }
39
+ form r60-3/sec-4.4.1 {
40
+ file "04-04-01-manufacturer"
41
+ title "Manufacturer of the Specimen"
42
+ required always
43
+ }
44
+ form r60-3/sec-4.4.2 {
45
+ file "04-04-02-applicant"
46
+ title "Applicant Information"
47
+ required always
48
+ }
49
+ form r60-3/sec-4.4.3 {
50
+ file "04-04-03-testing-laboratories"
51
+ title "Testing Laboratories"
52
+ required always
53
+ }
54
+ form r60-3/sec-4.5 {
55
+ file "04-05-load-cell-type-info"
56
+ title "Load Cell Type Information"
57
+ required always
58
+ }
59
+ form r60-3/sec-4.6 {
60
+ file "04-06-accessories"
61
+ title "Accessories"
62
+ required always
63
+ }
64
+ form r60-3/sec-4.7 {
65
+ file "04-07-sample-selection"
66
+ title "Selection of Samples and Adjustments (§4.7–4.8)"
67
+ required always
68
+ }
69
+ form r60-3/sec-4.9.1 {
70
+ file "04-09-01-general-info"
71
+ title "Additional Information — General"
72
+ required always
73
+ }
74
+ form r60-3/sec-4.9.2 {
75
+ file "04-09-02-performance-info"
76
+ title "Additional Information — Performance Tests"
77
+ required always
78
+ }
79
+ form r60-3/sec-4.9.3 {
80
+ file "04-09-03-digital-info"
81
+ title "Additional Information — Digital Load Cells"
82
+ required conditional
83
+ applicability {
84
+ technology: [digital, digital-with-processing]
85
+ }
86
+ }
87
+ form r60-3/sec-4.9.4 {
88
+ file "04-09-04-photographs"
89
+ title "Photographs of Examinations and Tests"
90
+ required always
91
+ }
92
+ form r60-3/sec-4.9.5 {
93
+ file "04-09-05-documentation"
94
+ title "Documentation Supplied with the Test Pattern"
95
+ required always
96
+ }
97
+ form r60-3/sec-4.9.6 {
98
+ file "04-09-06-inscriptions"
99
+ title "Inscriptions and Presentations"
100
+ required always
101
+ }
102
+ form r60-3/sec-4.9.7 {
103
+ file "04-09-07-model-range"
104
+ title "Various Designs within the Model Range"
105
+ required always
106
+ }
107
+ form r60-3/sec-4.9.12 {
108
+ file "04-09-12-previous-tests"
109
+ title "Results of Previous Tests Taken into Account"
110
+ required always
111
+ }
112
+ form r60-3/sec-4.10.1 {
113
+ file "04-10-01-force-generating-system"
114
+ title "Test Equipment — Force Generating System"
115
+ required always
116
+ }
117
+ form r60-3/sec-4.10.2 {
118
+ file "04-10-02-weights"
119
+ title "Test Equipment — Weights"
120
+ required always
121
+ }
122
+ form r60-3/sec-4.10.3 {
123
+ file "04-10-03-temperature-chamber"
124
+ title "Test Equipment — Temperature Chamber"
125
+ required always
126
+ }
127
+ form r60-3/sec-4.10.4 {
128
+ file "04-10-04-climate-chamber"
129
+ title "Test Equipment — Climate Chamber"
130
+ required conditional
131
+ applicability {
132
+ humidity_class: [CH, SH]
133
+ }
134
+ }
135
+ form r60-3/sec-4.10.5 {
136
+ file "04-10-05-indicator"
137
+ title "Test Equipment — Indicator"
138
+ required always
139
+ }
140
+ form r60-3/sec-4.10.6 {
141
+ file "04-10-06-terminal"
142
+ title "Test Equipment — Terminal"
143
+ required conditional
144
+ applicability {
145
+ technology: [analogue-active, digital, digital-with-processing]
146
+ }
147
+ }
148
+ form r60-3/sec-4.10.7 {
149
+ file "04-10-07-barometric-pressure-meter"
150
+ title "Test Equipment — Barometric Pressure Meter"
151
+ required always
152
+ }
153
+ form r60-3/sec-4.10.8 {
154
+ file "04-10-08-thermometer"
155
+ title "Test Equipment — Thermometer"
156
+ required always
157
+ }
158
+ form r60-3/sec-4.10.9 {
159
+ file "04-10-09-moisture-analyser"
160
+ title "Test Equipment — Moisture Analyser"
161
+ required conditional
162
+ applicability {
163
+ humidity_class: [CH, SH]
164
+ }
165
+ }
166
+ form r60-3/sec-4.10.10 {
167
+ file "04-10-10-additional-test-equipment"
168
+ title "Test Equipment — Additional Equipment"
169
+ required always
170
+ }
171
+ form r60-3/sec-4.10.11 {
172
+ file "04-10-11-remarks"
173
+ title "Test Equipment — Remarks"
174
+ required always
175
+ }
176
+ form r60-3/form-1 {
177
+ file "test-usage-matrix"
178
+ title "Test Equipment Usage Matrix"
179
+ required always
180
+ }
181
+ }
182
+ section 5 {
183
+ title "Examinations"
184
+ description "Visual and documentation examinations per R 60-2 sections 2.5–2.6"
185
+ form r60-3/sec-5.1 {
186
+ file "marking-examination"
187
+ title "Marking Examination"
188
+ conformance_test /conf/examinations/inscriptions
189
+ requirements { /req/technical/mandatory-markings /req/technical/class-designation /req/technical/load-type-designation /req/technical/temperature-designation /req/technical/humidity-designation /req/technical/nlc-designation }
190
+ required always
191
+ }
192
+ form r60-3/sec-5.2 {
193
+ file "suitability-examination"
194
+ title "Suitability for Testing"
195
+ conformance_test /conf/examinations/suitability
196
+ requirements { /req/technical/mandatory-additional-info }
197
+ required always
198
+ }
199
+ form r60-3/sec-5.3 {
200
+ file "software-examination"
201
+ title "Software Examination"
202
+ conformance_test /conf/examinations/software
203
+ requirements { /req/technical/software }
204
+ required conditional
205
+ applicability {
206
+ technology: [analogue-active, digital]
207
+ }
208
+ }
209
+ form r60-3/sec-5.4 {
210
+ file "documentation-examination"
211
+ title "Documentation Examination"
212
+ conformance_test /conf/examinations/documentation
213
+ requirements { /req/technical/mandatory-additional-info }
214
+ required always
215
+ }
216
+ }
217
+ section 6 {
218
+ title "Performance Tests"
219
+ description "Metrological and environmental performance tests per R 60-2 sections 2.10.1–2.10.7"
220
+ form r60-3/sec-6.1 {
221
+ file "performance-test-summary"
222
+ title "Results of Performance Tests"
223
+ required always
224
+ }
225
+ form r60-3/sec-6.2 {
226
+ file "initial-tests"
227
+ title "Initial Tests and General Notes"
228
+ required always
229
+ }
230
+ subsection "Base Metrological Tests" {
231
+ description "Required for all load cells"
232
+ form r60-3/table-6.3-6.4 {
233
+ file "load-test"
234
+ title "Load Test Data (parameterized: 3 runs for C/D, 5 runs for A/B)"
235
+ conformance_test /conf/metrological-tests/measurement-error-repeatability-mdlo
236
+ requirements { /req/metrological/mpe /req/metrological/repeatability }
237
+ required conditional
238
+ applicability {
239
+ accuracy_class: [A, B, C, D]
240
+ }
241
+ }
242
+ form r60-3/table-6.5 {
243
+ file "load-cell-errors"
244
+ title "Load Cell Errors (E_L)"
245
+ conformance_test /conf/metrological-tests/measurement-error-repeatability-mdlo
246
+ requirements { /req/metrological/mpe }
247
+ required always
248
+ }
249
+ form r60-3/table-6.6 {
250
+ file "repeatability"
251
+ title "Repeatability Errors (E_R)"
252
+ conformance_test /conf/metrological-tests/measurement-error-repeatability-mdlo
253
+ requirements { /req/metrological/repeatability }
254
+ required always
255
+ }
256
+ form r60-3/table-6.7 {
257
+ file "temperature-mdlo"
258
+ title "Temperature Effect on MDLO (C_M)"
259
+ conformance_test /conf/metrological-tests/measurement-error-repeatability-mdlo
260
+ requirements { /req/metrological/temperature-effect-mdlo }
261
+ required always
262
+ }
263
+ form r60-3/table-6.8 {
264
+ file "creep-dr"
265
+ title "Creep (C_C) and DR (C_DR)"
266
+ conformance_test /conf/metrological-tests/creep
267
+ requirements { /req/metrological/creep /req/metrological/creep-20-30 /req/metrological/dr }
268
+ required always
269
+ }
270
+ form r60-3/table-6.9 {
271
+ file "barometric-pressure"
272
+ title "Barometric Pressure Effects (C_P)"
273
+ conformance_test /conf/metrological-tests/barometric-pressure
274
+ requirements { /req/metrological/barometric-pressure }
275
+ required conditional
276
+ notes "May not be necessary depending on the design of the load cell (R 60-3, 2.1.6 footnote) — required unless the manufacturer demonstrates the cell is pressure-insensitive"
277
+ }
278
+ }
279
+ subsection "Humidity Tests" {
280
+ description "Conditional on humidity class designation"
281
+ form r60-3/table-6.10.1 {
282
+ file "humidity-ch"
283
+ title "Humidity Effects CH (Cyclic)"
284
+ conformance_test /conf/metrological-tests/humidity-ch
285
+ requirements { /req/metrological/humidity-ch /req/metrological/mpe }
286
+ required conditional
287
+ applicability {
288
+ humidity_class: [CH]
289
+ }
290
+ }
291
+ form r60-3/table-6.10.2 {
292
+ file "humidity-sh"
293
+ title "Humidity Effects SH (Steady-State)"
294
+ conformance_test /conf/metrological-tests/humidity-sh
295
+ requirements { /req/metrological/humidity-sh }
296
+ required conditional
297
+ applicability {
298
+ humidity_class: [SH]
299
+ }
300
+ }
301
+ }
302
+ subsection "Electronic Load Cell Tests" {
303
+ description "Required for analogue-active and digital load cells only"
304
+ applicability {
305
+ technology: [analogue-active, digital]
306
+ }
307
+ form r60-3/form-6.11 {
308
+ file "warm-up-time"
309
+ title "Warm-Up Time"
310
+ conformance_test /conf/electronic-tests/warm-up-time
311
+ requirements { /req/electronic/warm-up-time }
312
+ required conditional
313
+ applicability {
314
+ technology: [analogue-active, digital]
315
+ }
316
+ }
317
+ form r60-3/form-6.12 {
318
+ file "power-voltage"
319
+ title "Power Voltage Variations"
320
+ conformance_test /conf/electronic-tests/power-voltage
321
+ requirements { /req/electronic/power-voltage-ac /req/electronic/power-voltage-dc /req/electronic/power-voltage-variations }
322
+ required conditional
323
+ applicability {
324
+ technology: [analogue-active, digital]
325
+ }
326
+ }
327
+ form r60-3/form-6.13 {
328
+ file "short-time-power"
329
+ title "Short-Time Power Reductions"
330
+ conformance_test /conf/electronic-tests/short-time-power
331
+ requirements { /req/electronic/disturbances /req/electronic/no-significant-faults }
332
+ required conditional
333
+ applicability {
334
+ technology: [analogue-active, digital]
335
+ }
336
+ }
337
+ form r60-3/form-6.14 {
338
+ file "bursts"
339
+ title "Bursts (EFT)"
340
+ conformance_test /conf/electronic-tests/bursts
341
+ requirements { /req/electronic/disturbances /req/electronic/no-significant-faults }
342
+ required conditional
343
+ applicability {
344
+ technology: [analogue-active, digital]
345
+ }
346
+ }
347
+ form r60-3/form-6.15 {
348
+ file "surge"
349
+ title "Surge"
350
+ conformance_test /conf/electronic-tests/surge
351
+ requirements { /req/electronic/disturbances /req/electronic/no-significant-faults }
352
+ required conditional
353
+ applicability {
354
+ technology: [analogue-active, digital]
355
+ }
356
+ }
357
+ form r60-3/form-6.16 {
358
+ file "esd"
359
+ title "Electrostatic Discharge"
360
+ conformance_test /conf/electronic-tests/esd
361
+ requirements { /req/electronic/disturbances /req/electronic/no-significant-faults }
362
+ required conditional
363
+ applicability {
364
+ technology: [analogue-active, digital]
365
+ }
366
+ }
367
+ form r60-3/form-6.17 {
368
+ file "emc-susceptibility"
369
+ title "Electromagnetic Susceptibility"
370
+ conformance_test /conf/electronic-tests/emc-susceptibility
371
+ requirements { /req/electronic/disturbances /req/electronic/no-significant-faults }
372
+ required conditional
373
+ applicability {
374
+ technology: [analogue-active, digital]
375
+ }
376
+ }
377
+ form r60-3/form-6.18 {
378
+ file "conducted-emc"
379
+ title "Conducted Electromagnetic Fields"
380
+ conformance_test /conf/electronic-tests/conducted-emc
381
+ requirements { /req/electronic/disturbances /req/electronic/no-significant-faults }
382
+ required conditional
383
+ applicability {
384
+ technology: [analogue-active, digital]
385
+ }
386
+ }
387
+ form r60-3/form-6.19 {
388
+ file "span-stability"
389
+ title "Span Stability"
390
+ conformance_test /conf/electronic-tests/span-stability
391
+ requirements { /req/electronic/span-stability }
392
+ required conditional
393
+ applicability {
394
+ accuracy_class: [B, C, D]
395
+ }
396
+ }
397
+ }
398
+ }
399
+ }
@@ -0,0 +1,426 @@
1
+ # OIML R 91 — test report skeleton (kernel 1.14.0's test_report_skeleton,
2
+ # TODO.roadmap/40): the R 91-3:2025 test report format — sections and the
3
+ # form inventory (C140 resolves the entries against the forms register).
4
+ # The R 91-4 type evaluation report is a separate document — its template
5
+ # is the evaluation-report family, not this register.
6
+ test_report_skeleton r91-3/test-report {
7
+ title "OIML R 91-3:2025 — Test report format for speed meters"
8
+ description "The complete test report for an OIML R 91 speed meter evaluation, structured per the R 91-3:2025 report format: the metrological field test, the laboratory programme per R 91-2, and the category-specific tests."
9
+ note "R 91-4 additionally defines the TYPE EVALUATION REPORT format — a separate document from the lab test report (R 91-3); its template is the evaluation-report family, not this register."
10
+ section 01 {
11
+ title "Metrological field test (OIML R 91-2, 4)"
12
+ form r91-3/report-1-1 {
13
+ file "01-01-field-test"
14
+ title "1.1 Traffic condition during measurement (metrological field test)"
15
+ conformance_test /conf/field/stationary-field-test
16
+ requirements { /req/metrological/mpe-stationary /req/metrological/measuring-intervals /req/metrological/indicated-speed /req/category-moving/stationary-mode }
17
+ required always
18
+ }
19
+ form r91-3/report-1-2 {
20
+ file "01-02-statistical-analysis"
21
+ title "1.2 Statistical analysis of errors (optional)"
22
+ conformance_test /conf/field/stationary-field-test
23
+ requirements { /req/metrological/mpe-stationary }
24
+ required conditional
25
+ notes "Optional per R 91-2, 4.7 — the statistical analysis is completed when the field-test error distribution warrants it."
26
+ }
27
+ form r91-3/report-1-3 {
28
+ file "01-03-image-evidence"
29
+ title "1.3 Assignment to image evidence"
30
+ conformance_test /conf/field/stationary-field-test
31
+ requirements { /req/metrological/vehicle-identification }
32
+ required always
33
+ }
34
+ }
35
+ section 02 {
36
+ title "Metrological laboratory tests by traffic simulation (OIML R 91-2, 5)"
37
+ form r91-3/report-2-1 {
38
+ file "02-01-dynamic-performance"
39
+ title "2.1 Dynamic performance test"
40
+ conformance_test /conf/field/dynamic-performance
41
+ requirements { /req/metrological/mpe-stationary /req/metrological/relevant-speed-values }
42
+ required always
43
+ }
44
+ form r91-3/report-2-2 {
45
+ file "02-02-speed-linearity"
46
+ title "2.2 Speed linearity test"
47
+ conformance_test /conf/linearities/speed-linearity
48
+ requirements { /req/metrological/linearity-limit }
49
+ required always
50
+ }
51
+ form r91-3/report-2-3 {
52
+ file "02-03-distance-linearity"
53
+ title "2.3 Distance linearity test"
54
+ conformance_test /conf/linearities/distance-linearity
55
+ requirements { /req/metrological/distance-angle-indication }
56
+ required always
57
+ }
58
+ form r91-3/report-2-4 {
59
+ file "02-04-angle-linearity"
60
+ title "2.4 Angle linearity test"
61
+ conformance_test /conf/linearities/angle-linearity
62
+ requirements { /req/metrological/distance-angle-indication }
63
+ required always
64
+ }
65
+ }
66
+ section 03 {
67
+ title "Influence factor and disturbance tests (OIML R 91-2, 6)"
68
+ form r91-3/report-3-1 {
69
+ file "03-01-dry-heat-operating"
70
+ title "3.1 Dry heat (operating)"
71
+ conformance_test /conf/influence/dry-heat-operating
72
+ requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
73
+ required always
74
+ }
75
+ form r91-3/report-3-2 {
76
+ file "03-02-dry-heat-storage"
77
+ title "3.2 Dry heat (storage)"
78
+ conformance_test /conf/disturbances/dry-heat-storage
79
+ requirements { /req/metrological/disturbances }
80
+ required always
81
+ }
82
+ form r91-3/report-3-3 {
83
+ file "03-03-cold-operating"
84
+ title "3.3 Cold (operating)"
85
+ conformance_test /conf/influence/cold-operating
86
+ requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
87
+ required always
88
+ }
89
+ form r91-3/report-3-4 {
90
+ file "03-04-cold-storage"
91
+ title "3.4 Cold (storage)"
92
+ conformance_test /conf/disturbances/cold-storage
93
+ requirements { /req/metrological/disturbances }
94
+ required always
95
+ }
96
+ form r91-3/report-3-5 {
97
+ file "03-05-damp-heat-cyclic"
98
+ title "3.5 Damp heat, cyclic (condensing)"
99
+ conformance_test /conf/influence/damp-heat-cyclic
100
+ requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
101
+ required always
102
+ }
103
+ form r91-3/report-3-6 {
104
+ file "03-06-water"
105
+ title "3.6 Water (optional)"
106
+ conformance_test /conf/disturbances/water
107
+ requirements { /req/metrological/disturbances }
108
+ required conditional
109
+ notes "Optional test (R 91-2, 6.1 Tables 1-2) — applied when relevant for the declared point of use and installation conditions."
110
+ }
111
+ form r91-3/report-3-7 {
112
+ file "03-07-sand-and-dust"
113
+ title "3.7 Sand and dust (optional)"
114
+ conformance_test /conf/disturbances/sand-and-dust
115
+ requirements { /req/metrological/disturbances }
116
+ required conditional
117
+ notes "Optional test (R 91-2, 6.1 Tables 1-2) — applied when relevant for the declared point of use and installation conditions."
118
+ }
119
+ form r91-3/report-3-8 {
120
+ file "03-08-salt-mist"
121
+ title "3.8 Salt mist (optional)"
122
+ conformance_test /conf/disturbances/salt-mist
123
+ requirements { /req/metrological/disturbances }
124
+ required conditional
125
+ notes "Optional test (R 91-2, 6.1 Table 1, row 6) — applied when relevant for the declared point of use and installation conditions."
126
+ }
127
+ form r91-3/report-3-9 {
128
+ file "03-09-vibration-random"
129
+ title "3.9 Vibration (random)"
130
+ conformance_test /conf/influence/vibration-random
131
+ requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
132
+ required always
133
+ }
134
+ form r91-3/report-3-10 {
135
+ file "03-10-mechanical-shock"
136
+ title "3.10 Mechanical shock"
137
+ conformance_test /conf/disturbances/mechanical-shock
138
+ requirements { /req/metrological/disturbances }
139
+ required always
140
+ }
141
+ form r91-3/report-3-11 {
142
+ file "03-11-dc-mains-voltage-variation"
143
+ title "3.11 DC mains voltage variation"
144
+ conformance_test /conf/influence/dc-mains-voltage-variation
145
+ requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
146
+ required always
147
+ }
148
+ form r91-3/report-3-12 {
149
+ file "03-12-ripple-on-dc-mains"
150
+ title "3.12 Ripple on DC mains power"
151
+ conformance_test /conf/disturbances/ripple-on-dc-mains
152
+ requirements { /req/metrological/disturbances }
153
+ required always
154
+ }
155
+ form r91-3/report-3-13 {
156
+ file "03-13-ac-mains-voltage-variation"
157
+ title "3.13 AC mains voltage variation"
158
+ conformance_test /conf/influence/ac-mains-voltage-variation
159
+ requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
160
+ required always
161
+ }
162
+ form r91-3/report-3-14 {
163
+ file "03-14-ac-mains-frequency-variation"
164
+ title "3.14 AC mains frequency variation"
165
+ conformance_test /conf/influence/ac-mains-frequency-variation
166
+ requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
167
+ required always
168
+ }
169
+ form r91-3/report-3-15 {
170
+ file "03-15-dc-mains-voltage-dips"
171
+ title "3.15 DC mains voltage dips, short interruptions and (short term) voltage variations"
172
+ conformance_test /conf/disturbances/dc-mains-voltage-dips
173
+ requirements { /req/metrological/disturbances }
174
+ required always
175
+ }
176
+ form r91-3/report-3-16 {
177
+ file "03-16-ac-mains-voltage-dips"
178
+ title "3.16 AC mains voltage dips, short interruptions and reductions"
179
+ conformance_test /conf/disturbances/ac-mains-voltage-dips
180
+ requirements { /req/metrological/disturbances }
181
+ required always
182
+ }
183
+ form r91-3/report-3-17 {
184
+ file "03-17-ac-mains-frequency-harmonics"
185
+ title "3.17 AC mains frequency harmonics"
186
+ conformance_test /conf/disturbances/ac-mains-frequency-harmonics
187
+ requirements { /req/metrological/disturbances }
188
+ required always
189
+ }
190
+ form r91-3/report-3-18 {
191
+ file "03-18-vlf-lf-disturbances"
192
+ title "3.18 VLF and LF disturbances on AC and DC mains"
193
+ conformance_test /conf/disturbances/vlf-lf-disturbances-ac-mains
194
+ requirements { /req/metrological/disturbances }
195
+ required always
196
+ }
197
+ form r91-3/report-3-19 {
198
+ file "03-19-bursts-ac-dc-mains"
199
+ title "3.19 Bursts (transients) on AC and DC mains"
200
+ conformance_test /conf/disturbances/bursts-ac-dc-mains
201
+ requirements { /req/metrological/disturbances }
202
+ required always
203
+ }
204
+ form r91-3/report-3-20 {
205
+ file "03-20-surges-ac-dc-mains"
206
+ title "3.20 Surges on AC and DC mains power lines"
207
+ conformance_test /conf/disturbances/surges-ac-dc-mains
208
+ requirements { /req/metrological/disturbances }
209
+ required always
210
+ }
211
+ form r91-3/report-3-21 {
212
+ file "03-21-bursts-signal-lines"
213
+ title "3.21 Bursts (transients) on signal, data and control lines"
214
+ conformance_test /conf/disturbances/bursts-signal-lines
215
+ requirements { /req/metrological/disturbances }
216
+ required always
217
+ }
218
+ form r91-3/report-3-22 {
219
+ file "03-22-surges-signal-lines"
220
+ title "3.22 Surges on signal, data and control lines"
221
+ conformance_test /conf/disturbances/surges-signal-lines
222
+ requirements { /req/metrological/disturbances }
223
+ required always
224
+ }
225
+ form r91-3/report-3-23 {
226
+ file "03-23-ac-mains-magnetic-field"
227
+ title "3.23 AC mains power frequency magnetic field"
228
+ conformance_test /conf/disturbances/ac-mains-power-frequency-magnetic-field
229
+ requirements { /req/metrological/disturbances }
230
+ required always
231
+ }
232
+ form r91-3/report-3-24 {
233
+ file "03-24-conducted-rf-common-mode"
234
+ title "3.24 Conducted (common mode) currents generated by RF electromagnetic fields"
235
+ conformance_test /conf/disturbances/conducted-rf-common-mode-currents
236
+ requirements { /req/metrological/disturbances }
237
+ required always
238
+ }
239
+ form r91-3/report-3-25 {
240
+ file "03-25-rf-electromagnetic-fields"
241
+ title "3.25 RF electromagnetic fields"
242
+ conformance_test /conf/disturbances/rf-electromagnetic-fields
243
+ requirements { /req/metrological/disturbances }
244
+ required always
245
+ }
246
+ form r91-3/report-3-26 {
247
+ file "03-26-electrostatic-discharges"
248
+ title "3.26 Electrostatic discharges"
249
+ conformance_test /conf/disturbances/electrostatic-discharges
250
+ requirements { /req/metrological/disturbances }
251
+ required always
252
+ }
253
+ form r91-3/report-3-27 {
254
+ file "03-27-internal-battery-low-voltage"
255
+ title "3.27 Low voltage of internal battery"
256
+ conformance_test /conf/influence/internal-battery-low-voltage
257
+ requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
258
+ required always
259
+ }
260
+ form r91-3/report-3-28 {
261
+ file "03-28-road-vehicle-battery"
262
+ title "3.28 Voltage variations of a road vehicle battery"
263
+ conformance_test /conf/influence/road-vehicle-battery-voltage-variations
264
+ requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
265
+ required always
266
+ }
267
+ form r91-3/report-3-29 {
268
+ file "03-29-transient-supply-lines"
269
+ title "3.29 Electrical transient conduction along supply lines of external 12 V and 24 V batteries"
270
+ conformance_test /conf/disturbances/transient-conduction-supply-lines
271
+ requirements { /req/metrological/disturbances }
272
+ required always
273
+ }
274
+ form r91-3/report-3-30 {
275
+ file "03-30-transient-other-lines"
276
+ title "3.30 Electrical transient conduction via lines other than supply lines for external 12 V and 24 V batteries"
277
+ conformance_test /conf/disturbances/transient-conduction-other-lines
278
+ requirements { /req/metrological/disturbances }
279
+ required always
280
+ }
281
+ form r91-3/report-3-31 {
282
+ file "03-31-battery-cranking"
283
+ title "3.31 Battery voltage variations during cranking"
284
+ conformance_test /conf/disturbances/battery-voltage-cranking
285
+ requirements { /req/metrological/disturbances }
286
+ required always
287
+ }
288
+ form r91-3/report-3-32 {
289
+ file "03-32-load-dump"
290
+ title "3.32 Load dump test"
291
+ conformance_test /conf/disturbances/load-dump
292
+ requirements { /req/metrological/disturbances }
293
+ required always
294
+ }
295
+ form r91-3/report-3-33 {
296
+ file "03-33-acceleration"
297
+ title "3.33 Acceleration test"
298
+ conformance_test /conf/field/acceleration-test
299
+ requirements { /req/metrological/mpe-stationary }
300
+ required always
301
+ }
302
+ form r91-3/report-3-34 {
303
+ file "03-34-further-influence"
304
+ title "3.34 Further influence quantity tests"
305
+ requirements { /req/metrological/linearity-limit }
306
+ required always
307
+ }
308
+ form r91-3/report-3-35 {
309
+ file "03-35-installation-alignment"
310
+ title "3.35 Installation and alignment of sensor and camera"
311
+ conformance_test /conf/linearities/alignment-misalignment
312
+ requirements { /req/category-across-road/alignment-error }
313
+ required always
314
+ }
315
+ }
316
+ section 04 {
317
+ title "Tests specific to certain categories of speed meters (OIML R 91-2, 7)"
318
+ form r91-3/report-4-1 {
319
+ file "04-01-doppler-radar"
320
+ title "4.1 Doppler-radar based speed meters"
321
+ requirements { /req/category-doppler-radar/beam-width /req/category-doppler-radar/frequency-spectrum /req/category-doppler-radar/spectrum-stability /req/category-doppler-radar/side-lobe }
322
+ required always
323
+ }
324
+ form r91-3/report-4-2 {
325
+ file "04-02-range-finding"
326
+ title "4.2 Range-finding based speed meters"
327
+ requirements { /req/category-range-finding/beam-width /req/category-range-finding/max-distance-viewfinder /req/category-range-finding/pulse-stability /req/category-range-finding/wavelength }
328
+ required always
329
+ }
330
+ form r91-3/report-4-3 {
331
+ file "04-03-average-speed"
332
+ title "4.3 Average speed meters"
333
+ requirements { /req/category-average-speed/detection-field-size /req/category-average-speed/time-synchronisation /req/category-average-speed/image-time-evidence }
334
+ required always
335
+ }
336
+ form r91-3/report-4-4 {
337
+ file "04-04-fixed-distance"
338
+ title "4.4 Fixed-distance speed meters"
339
+ requirements { /req/category-fixed-distance/detection-point-distance /req/category-fixed-distance/redundancy }
340
+ required always
341
+ }
342
+ form r91-3/report-4-5 {
343
+ file "04-05-image-based"
344
+ title "4.5 Image based speed meters"
345
+ conformance_test /conf/category-image-based/image-quality
346
+ requirements { /req/category-image-based/image-quality /req/category-image-based/position-marking /req/category-image-based/position-distances }
347
+ required always
348
+ }
349
+ form r91-3/report-4-6 {
350
+ file "04-06-across-road"
351
+ title "4.6 Across-the-road speed meters"
352
+ conformance_test /conf/examinations/across-road-examination
353
+ requirements { /req/category-across-road/reference-marking /req/category-across-road/cosine-verification }
354
+ required always
355
+ }
356
+ }
357
+ section 05 {
358
+ title "Moving speed meters (OIML R 91-2, 7.7)"
359
+ form r91-3/report-5-1 {
360
+ file "05-01-moving-field-test"
361
+ title "5.1 Moving metrological field test"
362
+ conformance_test /conf/field/moving-field-test
363
+ requirements { /req/category-moving/mpe-moving }
364
+ required always
365
+ }
366
+ form r91-3/report-5-2 {
367
+ file "05-02-ego-field-test"
368
+ title "5.2 Metrological field test of the ego speed meter"
369
+ conformance_test /conf/field/ego-field-test
370
+ requirements { /req/category-moving/ego-speed /req/category-moving/ego-adjustment }
371
+ required always
372
+ }
373
+ form r91-3/report-5-3 {
374
+ file "05-03-moving-traffic-simulation"
375
+ title "5.3 Traffic simulation for moving speed meters"
376
+ requirements { /req/category-moving/mpe-moving /req/category-moving/ego-speed }
377
+ required always
378
+ }
379
+ }
380
+ section 06 {
381
+ title "Software (OIML R 91-2, 8.3)"
382
+ form r91-3/report-6-1 {
383
+ file "06-01-software-general"
384
+ title "6.1 General requirements [mandatory]"
385
+ conformance_test /conf/software/software-examination
386
+ requirements { /req/technical/software }
387
+ required always
388
+ }
389
+ form r91-3/report-6-2 {
390
+ file "06-02-software-protection"
391
+ title "6.2 Software protection [mandatory]"
392
+ conformance_test /conf/software/software-examination
393
+ requirements { /req/technical/software }
394
+ required always
395
+ }
396
+ form r91-3/report-6-3 {
397
+ file "06-03-software-hardware-support"
398
+ title "6.3 Support of hardware features [mandatory]"
399
+ conformance_test /conf/software/software-examination
400
+ requirements { /req/technical/software }
401
+ required always
402
+ }
403
+ form r91-3/report-6-4 {
404
+ file "06-04-software-separation"
405
+ title "6.4 Specification and separation of legally relevant parts and specification of interfaces [optional]"
406
+ conformance_test /conf/software/software-examination
407
+ requirements { /req/technical/software }
408
+ required always
409
+ }
410
+ form r91-3/report-6-5 {
411
+ file "06-05-software-maintenance"
412
+ title "6.5 Maintenance and re-configuration [optional]"
413
+ conformance_test /conf/software/software-examination
414
+ requirements { /req/technical/software }
415
+ required always
416
+ }
417
+ }
418
+ section 07 {
419
+ title "General remarks"
420
+ form r91-3/report-general-remarks {
421
+ file "07-general-remarks"
422
+ title "General remarks"
423
+ required always
424
+ }
425
+ }
426
+ }
package/package.json CHANGED
@@ -1,6 +1,6 @@
1
1
  {
2
2
  "name": "@oimlsmart/primmel-packages",
3
- "version": "0.19.0",
3
+ "version": "0.20.0",
4
4
  "description": "The OIML SMART platform's authoritative model content: every Recommendation, the OIML-CS scheme, the CASCO foundations, the shared modules, and the product/program reference packages as Primmel (.prl) packages — the single source of truth the platform's data trees regenerate from. Consumed by the smart monorepo (oimlsmart/smart) at a pinned version (TODO.repos/02).",
5
5
  "type": "module",
6
6
  "repository": {