@oimlsmart/primmel-packages 0.18.0 → 0.20.0

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
@@ -0,0 +1,426 @@
1
+ # OIML R 91 — test report skeleton (kernel 1.14.0's test_report_skeleton,
2
+ # TODO.roadmap/40): the R 91-3:2025 test report format — sections and the
3
+ # form inventory (C140 resolves the entries against the forms register).
4
+ # The R 91-4 type evaluation report is a separate document — its template
5
+ # is the evaluation-report family, not this register.
6
+ test_report_skeleton r91-3/test-report {
7
+ title "OIML R 91-3:2025 — Test report format for speed meters"
8
+ description "The complete test report for an OIML R 91 speed meter evaluation, structured per the R 91-3:2025 report format: the metrological field test, the laboratory programme per R 91-2, and the category-specific tests."
9
+ note "R 91-4 additionally defines the TYPE EVALUATION REPORT format — a separate document from the lab test report (R 91-3); its template is the evaluation-report family, not this register."
10
+ section 01 {
11
+ title "Metrological field test (OIML R 91-2, 4)"
12
+ form r91-3/report-1-1 {
13
+ file "01-01-field-test"
14
+ title "1.1 Traffic condition during measurement (metrological field test)"
15
+ conformance_test /conf/field/stationary-field-test
16
+ requirements { /req/metrological/mpe-stationary /req/metrological/measuring-intervals /req/metrological/indicated-speed /req/category-moving/stationary-mode }
17
+ required always
18
+ }
19
+ form r91-3/report-1-2 {
20
+ file "01-02-statistical-analysis"
21
+ title "1.2 Statistical analysis of errors (optional)"
22
+ conformance_test /conf/field/stationary-field-test
23
+ requirements { /req/metrological/mpe-stationary }
24
+ required conditional
25
+ notes "Optional per R 91-2, 4.7 — the statistical analysis is completed when the field-test error distribution warrants it."
26
+ }
27
+ form r91-3/report-1-3 {
28
+ file "01-03-image-evidence"
29
+ title "1.3 Assignment to image evidence"
30
+ conformance_test /conf/field/stationary-field-test
31
+ requirements { /req/metrological/vehicle-identification }
32
+ required always
33
+ }
34
+ }
35
+ section 02 {
36
+ title "Metrological laboratory tests by traffic simulation (OIML R 91-2, 5)"
37
+ form r91-3/report-2-1 {
38
+ file "02-01-dynamic-performance"
39
+ title "2.1 Dynamic performance test"
40
+ conformance_test /conf/field/dynamic-performance
41
+ requirements { /req/metrological/mpe-stationary /req/metrological/relevant-speed-values }
42
+ required always
43
+ }
44
+ form r91-3/report-2-2 {
45
+ file "02-02-speed-linearity"
46
+ title "2.2 Speed linearity test"
47
+ conformance_test /conf/linearities/speed-linearity
48
+ requirements { /req/metrological/linearity-limit }
49
+ required always
50
+ }
51
+ form r91-3/report-2-3 {
52
+ file "02-03-distance-linearity"
53
+ title "2.3 Distance linearity test"
54
+ conformance_test /conf/linearities/distance-linearity
55
+ requirements { /req/metrological/distance-angle-indication }
56
+ required always
57
+ }
58
+ form r91-3/report-2-4 {
59
+ file "02-04-angle-linearity"
60
+ title "2.4 Angle linearity test"
61
+ conformance_test /conf/linearities/angle-linearity
62
+ requirements { /req/metrological/distance-angle-indication }
63
+ required always
64
+ }
65
+ }
66
+ section 03 {
67
+ title "Influence factor and disturbance tests (OIML R 91-2, 6)"
68
+ form r91-3/report-3-1 {
69
+ file "03-01-dry-heat-operating"
70
+ title "3.1 Dry heat (operating)"
71
+ conformance_test /conf/influence/dry-heat-operating
72
+ requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
73
+ required always
74
+ }
75
+ form r91-3/report-3-2 {
76
+ file "03-02-dry-heat-storage"
77
+ title "3.2 Dry heat (storage)"
78
+ conformance_test /conf/disturbances/dry-heat-storage
79
+ requirements { /req/metrological/disturbances }
80
+ required always
81
+ }
82
+ form r91-3/report-3-3 {
83
+ file "03-03-cold-operating"
84
+ title "3.3 Cold (operating)"
85
+ conformance_test /conf/influence/cold-operating
86
+ requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
87
+ required always
88
+ }
89
+ form r91-3/report-3-4 {
90
+ file "03-04-cold-storage"
91
+ title "3.4 Cold (storage)"
92
+ conformance_test /conf/disturbances/cold-storage
93
+ requirements { /req/metrological/disturbances }
94
+ required always
95
+ }
96
+ form r91-3/report-3-5 {
97
+ file "03-05-damp-heat-cyclic"
98
+ title "3.5 Damp heat, cyclic (condensing)"
99
+ conformance_test /conf/influence/damp-heat-cyclic
100
+ requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
101
+ required always
102
+ }
103
+ form r91-3/report-3-6 {
104
+ file "03-06-water"
105
+ title "3.6 Water (optional)"
106
+ conformance_test /conf/disturbances/water
107
+ requirements { /req/metrological/disturbances }
108
+ required conditional
109
+ notes "Optional test (R 91-2, 6.1 Tables 1-2) — applied when relevant for the declared point of use and installation conditions."
110
+ }
111
+ form r91-3/report-3-7 {
112
+ file "03-07-sand-and-dust"
113
+ title "3.7 Sand and dust (optional)"
114
+ conformance_test /conf/disturbances/sand-and-dust
115
+ requirements { /req/metrological/disturbances }
116
+ required conditional
117
+ notes "Optional test (R 91-2, 6.1 Tables 1-2) — applied when relevant for the declared point of use and installation conditions."
118
+ }
119
+ form r91-3/report-3-8 {
120
+ file "03-08-salt-mist"
121
+ title "3.8 Salt mist (optional)"
122
+ conformance_test /conf/disturbances/salt-mist
123
+ requirements { /req/metrological/disturbances }
124
+ required conditional
125
+ notes "Optional test (R 91-2, 6.1 Table 1, row 6) — applied when relevant for the declared point of use and installation conditions."
126
+ }
127
+ form r91-3/report-3-9 {
128
+ file "03-09-vibration-random"
129
+ title "3.9 Vibration (random)"
130
+ conformance_test /conf/influence/vibration-random
131
+ requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
132
+ required always
133
+ }
134
+ form r91-3/report-3-10 {
135
+ file "03-10-mechanical-shock"
136
+ title "3.10 Mechanical shock"
137
+ conformance_test /conf/disturbances/mechanical-shock
138
+ requirements { /req/metrological/disturbances }
139
+ required always
140
+ }
141
+ form r91-3/report-3-11 {
142
+ file "03-11-dc-mains-voltage-variation"
143
+ title "3.11 DC mains voltage variation"
144
+ conformance_test /conf/influence/dc-mains-voltage-variation
145
+ requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
146
+ required always
147
+ }
148
+ form r91-3/report-3-12 {
149
+ file "03-12-ripple-on-dc-mains"
150
+ title "3.12 Ripple on DC mains power"
151
+ conformance_test /conf/disturbances/ripple-on-dc-mains
152
+ requirements { /req/metrological/disturbances }
153
+ required always
154
+ }
155
+ form r91-3/report-3-13 {
156
+ file "03-13-ac-mains-voltage-variation"
157
+ title "3.13 AC mains voltage variation"
158
+ conformance_test /conf/influence/ac-mains-voltage-variation
159
+ requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
160
+ required always
161
+ }
162
+ form r91-3/report-3-14 {
163
+ file "03-14-ac-mains-frequency-variation"
164
+ title "3.14 AC mains frequency variation"
165
+ conformance_test /conf/influence/ac-mains-frequency-variation
166
+ requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
167
+ required always
168
+ }
169
+ form r91-3/report-3-15 {
170
+ file "03-15-dc-mains-voltage-dips"
171
+ title "3.15 DC mains voltage dips, short interruptions and (short term) voltage variations"
172
+ conformance_test /conf/disturbances/dc-mains-voltage-dips
173
+ requirements { /req/metrological/disturbances }
174
+ required always
175
+ }
176
+ form r91-3/report-3-16 {
177
+ file "03-16-ac-mains-voltage-dips"
178
+ title "3.16 AC mains voltage dips, short interruptions and reductions"
179
+ conformance_test /conf/disturbances/ac-mains-voltage-dips
180
+ requirements { /req/metrological/disturbances }
181
+ required always
182
+ }
183
+ form r91-3/report-3-17 {
184
+ file "03-17-ac-mains-frequency-harmonics"
185
+ title "3.17 AC mains frequency harmonics"
186
+ conformance_test /conf/disturbances/ac-mains-frequency-harmonics
187
+ requirements { /req/metrological/disturbances }
188
+ required always
189
+ }
190
+ form r91-3/report-3-18 {
191
+ file "03-18-vlf-lf-disturbances"
192
+ title "3.18 VLF and LF disturbances on AC and DC mains"
193
+ conformance_test /conf/disturbances/vlf-lf-disturbances-ac-mains
194
+ requirements { /req/metrological/disturbances }
195
+ required always
196
+ }
197
+ form r91-3/report-3-19 {
198
+ file "03-19-bursts-ac-dc-mains"
199
+ title "3.19 Bursts (transients) on AC and DC mains"
200
+ conformance_test /conf/disturbances/bursts-ac-dc-mains
201
+ requirements { /req/metrological/disturbances }
202
+ required always
203
+ }
204
+ form r91-3/report-3-20 {
205
+ file "03-20-surges-ac-dc-mains"
206
+ title "3.20 Surges on AC and DC mains power lines"
207
+ conformance_test /conf/disturbances/surges-ac-dc-mains
208
+ requirements { /req/metrological/disturbances }
209
+ required always
210
+ }
211
+ form r91-3/report-3-21 {
212
+ file "03-21-bursts-signal-lines"
213
+ title "3.21 Bursts (transients) on signal, data and control lines"
214
+ conformance_test /conf/disturbances/bursts-signal-lines
215
+ requirements { /req/metrological/disturbances }
216
+ required always
217
+ }
218
+ form r91-3/report-3-22 {
219
+ file "03-22-surges-signal-lines"
220
+ title "3.22 Surges on signal, data and control lines"
221
+ conformance_test /conf/disturbances/surges-signal-lines
222
+ requirements { /req/metrological/disturbances }
223
+ required always
224
+ }
225
+ form r91-3/report-3-23 {
226
+ file "03-23-ac-mains-magnetic-field"
227
+ title "3.23 AC mains power frequency magnetic field"
228
+ conformance_test /conf/disturbances/ac-mains-power-frequency-magnetic-field
229
+ requirements { /req/metrological/disturbances }
230
+ required always
231
+ }
232
+ form r91-3/report-3-24 {
233
+ file "03-24-conducted-rf-common-mode"
234
+ title "3.24 Conducted (common mode) currents generated by RF electromagnetic fields"
235
+ conformance_test /conf/disturbances/conducted-rf-common-mode-currents
236
+ requirements { /req/metrological/disturbances }
237
+ required always
238
+ }
239
+ form r91-3/report-3-25 {
240
+ file "03-25-rf-electromagnetic-fields"
241
+ title "3.25 RF electromagnetic fields"
242
+ conformance_test /conf/disturbances/rf-electromagnetic-fields
243
+ requirements { /req/metrological/disturbances }
244
+ required always
245
+ }
246
+ form r91-3/report-3-26 {
247
+ file "03-26-electrostatic-discharges"
248
+ title "3.26 Electrostatic discharges"
249
+ conformance_test /conf/disturbances/electrostatic-discharges
250
+ requirements { /req/metrological/disturbances }
251
+ required always
252
+ }
253
+ form r91-3/report-3-27 {
254
+ file "03-27-internal-battery-low-voltage"
255
+ title "3.27 Low voltage of internal battery"
256
+ conformance_test /conf/influence/internal-battery-low-voltage
257
+ requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
258
+ required always
259
+ }
260
+ form r91-3/report-3-28 {
261
+ file "03-28-road-vehicle-battery"
262
+ title "3.28 Voltage variations of a road vehicle battery"
263
+ conformance_test /conf/influence/road-vehicle-battery-voltage-variations
264
+ requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
265
+ required always
266
+ }
267
+ form r91-3/report-3-29 {
268
+ file "03-29-transient-supply-lines"
269
+ title "3.29 Electrical transient conduction along supply lines of external 12 V and 24 V batteries"
270
+ conformance_test /conf/disturbances/transient-conduction-supply-lines
271
+ requirements { /req/metrological/disturbances }
272
+ required always
273
+ }
274
+ form r91-3/report-3-30 {
275
+ file "03-30-transient-other-lines"
276
+ title "3.30 Electrical transient conduction via lines other than supply lines for external 12 V and 24 V batteries"
277
+ conformance_test /conf/disturbances/transient-conduction-other-lines
278
+ requirements { /req/metrological/disturbances }
279
+ required always
280
+ }
281
+ form r91-3/report-3-31 {
282
+ file "03-31-battery-cranking"
283
+ title "3.31 Battery voltage variations during cranking"
284
+ conformance_test /conf/disturbances/battery-voltage-cranking
285
+ requirements { /req/metrological/disturbances }
286
+ required always
287
+ }
288
+ form r91-3/report-3-32 {
289
+ file "03-32-load-dump"
290
+ title "3.32 Load dump test"
291
+ conformance_test /conf/disturbances/load-dump
292
+ requirements { /req/metrological/disturbances }
293
+ required always
294
+ }
295
+ form r91-3/report-3-33 {
296
+ file "03-33-acceleration"
297
+ title "3.33 Acceleration test"
298
+ conformance_test /conf/field/acceleration-test
299
+ requirements { /req/metrological/mpe-stationary }
300
+ required always
301
+ }
302
+ form r91-3/report-3-34 {
303
+ file "03-34-further-influence"
304
+ title "3.34 Further influence quantity tests"
305
+ requirements { /req/metrological/linearity-limit }
306
+ required always
307
+ }
308
+ form r91-3/report-3-35 {
309
+ file "03-35-installation-alignment"
310
+ title "3.35 Installation and alignment of sensor and camera"
311
+ conformance_test /conf/linearities/alignment-misalignment
312
+ requirements { /req/category-across-road/alignment-error }
313
+ required always
314
+ }
315
+ }
316
+ section 04 {
317
+ title "Tests specific to certain categories of speed meters (OIML R 91-2, 7)"
318
+ form r91-3/report-4-1 {
319
+ file "04-01-doppler-radar"
320
+ title "4.1 Doppler-radar based speed meters"
321
+ requirements { /req/category-doppler-radar/beam-width /req/category-doppler-radar/frequency-spectrum /req/category-doppler-radar/spectrum-stability /req/category-doppler-radar/side-lobe }
322
+ required always
323
+ }
324
+ form r91-3/report-4-2 {
325
+ file "04-02-range-finding"
326
+ title "4.2 Range-finding based speed meters"
327
+ requirements { /req/category-range-finding/beam-width /req/category-range-finding/max-distance-viewfinder /req/category-range-finding/pulse-stability /req/category-range-finding/wavelength }
328
+ required always
329
+ }
330
+ form r91-3/report-4-3 {
331
+ file "04-03-average-speed"
332
+ title "4.3 Average speed meters"
333
+ requirements { /req/category-average-speed/detection-field-size /req/category-average-speed/time-synchronisation /req/category-average-speed/image-time-evidence }
334
+ required always
335
+ }
336
+ form r91-3/report-4-4 {
337
+ file "04-04-fixed-distance"
338
+ title "4.4 Fixed-distance speed meters"
339
+ requirements { /req/category-fixed-distance/detection-point-distance /req/category-fixed-distance/redundancy }
340
+ required always
341
+ }
342
+ form r91-3/report-4-5 {
343
+ file "04-05-image-based"
344
+ title "4.5 Image based speed meters"
345
+ conformance_test /conf/category-image-based/image-quality
346
+ requirements { /req/category-image-based/image-quality /req/category-image-based/position-marking /req/category-image-based/position-distances }
347
+ required always
348
+ }
349
+ form r91-3/report-4-6 {
350
+ file "04-06-across-road"
351
+ title "4.6 Across-the-road speed meters"
352
+ conformance_test /conf/examinations/across-road-examination
353
+ requirements { /req/category-across-road/reference-marking /req/category-across-road/cosine-verification }
354
+ required always
355
+ }
356
+ }
357
+ section 05 {
358
+ title "Moving speed meters (OIML R 91-2, 7.7)"
359
+ form r91-3/report-5-1 {
360
+ file "05-01-moving-field-test"
361
+ title "5.1 Moving metrological field test"
362
+ conformance_test /conf/field/moving-field-test
363
+ requirements { /req/category-moving/mpe-moving }
364
+ required always
365
+ }
366
+ form r91-3/report-5-2 {
367
+ file "05-02-ego-field-test"
368
+ title "5.2 Metrological field test of the ego speed meter"
369
+ conformance_test /conf/field/ego-field-test
370
+ requirements { /req/category-moving/ego-speed /req/category-moving/ego-adjustment }
371
+ required always
372
+ }
373
+ form r91-3/report-5-3 {
374
+ file "05-03-moving-traffic-simulation"
375
+ title "5.3 Traffic simulation for moving speed meters"
376
+ requirements { /req/category-moving/mpe-moving /req/category-moving/ego-speed }
377
+ required always
378
+ }
379
+ }
380
+ section 06 {
381
+ title "Software (OIML R 91-2, 8.3)"
382
+ form r91-3/report-6-1 {
383
+ file "06-01-software-general"
384
+ title "6.1 General requirements [mandatory]"
385
+ conformance_test /conf/software/software-examination
386
+ requirements { /req/technical/software }
387
+ required always
388
+ }
389
+ form r91-3/report-6-2 {
390
+ file "06-02-software-protection"
391
+ title "6.2 Software protection [mandatory]"
392
+ conformance_test /conf/software/software-examination
393
+ requirements { /req/technical/software }
394
+ required always
395
+ }
396
+ form r91-3/report-6-3 {
397
+ file "06-03-software-hardware-support"
398
+ title "6.3 Support of hardware features [mandatory]"
399
+ conformance_test /conf/software/software-examination
400
+ requirements { /req/technical/software }
401
+ required always
402
+ }
403
+ form r91-3/report-6-4 {
404
+ file "06-04-software-separation"
405
+ title "6.4 Specification and separation of legally relevant parts and specification of interfaces [optional]"
406
+ conformance_test /conf/software/software-examination
407
+ requirements { /req/technical/software }
408
+ required always
409
+ }
410
+ form r91-3/report-6-5 {
411
+ file "06-05-software-maintenance"
412
+ title "6.5 Maintenance and re-configuration [optional]"
413
+ conformance_test /conf/software/software-examination
414
+ requirements { /req/technical/software }
415
+ required always
416
+ }
417
+ }
418
+ section 07 {
419
+ title "General remarks"
420
+ form r91-3/report-general-remarks {
421
+ file "07-general-remarks"
422
+ title "General remarks"
423
+ required always
424
+ }
425
+ }
426
+ }
@@ -0,0 +1,111 @@
1
+ # oiml-twin-cert — TWIN CERTIFICATE TEMPLATE (TODO.v2/01 TCD-3;
2
+ # analysis/twin-certification-design.md Q3 "the certificate's claim").
3
+ #
4
+ # The twin certificate claims a SCOPED, CONDITIONAL relation (Q3): for
5
+ # instrument <model/serial>, the twin served at endpoint <endpoint-id> via
6
+ # operations <op-list> reflects the physical state of registers
7
+ # <aspect-list> within tolerance <δ per register> and freshness
8
+ # <fresh_within per register>, verified by probe schedule <schedule-id> on
9
+ # <date> (report <id>), with served-timestamp provenance declared
10
+ # (timestamp_fields). Validity is CONDITIONAL: continuous surveillance per
11
+ # monitor <monitor-id>; a sustained fail suspends; an unresolved fail
12
+ # withdraws.
13
+ #
14
+ # The characteristic rows are the claim's print projection. Every row
15
+ # resolves BY NAME from the certification decision's claim context
16
+ # (browser/src/services/twin-certificate.service.ts —
17
+ # twinCertificateCharacteristics): the twin's endpoint identity and the
18
+ # certified registers ride the decision evidence, never an entity-graph
19
+ # attribute (the program composes into nothing — there is no rec entity
20
+ # graph to bind, hence no attribute/dimension bindings on the rows).
21
+ # obligation: mandatory rows must carry a value on the issued certificate;
22
+ # the attestation-limitation row prints only when the probe evidence rode
23
+ # the attestation channel (controller decision 3: never silently upgraded).
24
+ #
25
+ # The certificate number format mirrors the Annex B shape with the
26
+ # program's own designators: TW-1 (the governing document,
27
+ # urn:oiml:pub:cs:twin-1:2027) / edition - T5 (the ISO/IEC 17067 scheme
28
+ # type the program self-classifies — type 5, surveillance-constitutive) -
29
+ # the scheme operator code - year.sequence.
30
+ #
31
+ # Row labels are the default-spelling (eng-Latn) content sets inline —
32
+ # the YAML twin re-wraps them as the Prose array the renderer resolves
33
+ # with src/data/prose.ts.
34
+ certificate_template certificate {
35
+ number_format "TW-1/{edition}-T5-{authority}-{year2}.{seq}"
36
+ characteristic instrument_model {
37
+ type string
38
+ label "Instrument model (the underlying certified type)"
39
+ obligation mandatory
40
+ }
41
+ characteristic instrument_serial {
42
+ type string
43
+ label "Instrument serial number (the certified unit — per-UNIT certification, type 5)"
44
+ obligation mandatory
45
+ }
46
+ characteristic twin_endpoint {
47
+ type string
48
+ label "Twin endpoint identifier (bound to the certified unit's serial)"
49
+ obligation mandatory
50
+ }
51
+ characteristic served_operations {
52
+ type string
53
+ label "Served operations certified"
54
+ obligation mandatory
55
+ }
56
+ characteristic fidelity_registers {
57
+ type string
58
+ label "Fidelity registers certified (served aspects)"
59
+ obligation mandatory
60
+ }
61
+ characteristic twin_tolerance_indication {
62
+ type string
63
+ label "Twin tolerance δ_indication (|served − reference| ≤ δ at every probe point)"
64
+ obligation mandatory
65
+ }
66
+ characteristic fresh_within_indication {
67
+ type string
68
+ label "Freshness window — indication register (fresh_within)"
69
+ obligation mandatory
70
+ }
71
+ characteristic fresh_within_op_state {
72
+ type string
73
+ label "Freshness window — state register (fresh_within)"
74
+ obligation mandatory
75
+ }
76
+ characteristic probe_schedule {
77
+ type string
78
+ label "Probe schedule (the certification's executable — range, envelope, transitions)"
79
+ obligation mandatory
80
+ }
81
+ characteristic verified_on {
82
+ type string
83
+ label "Verification date (the probe campaign's completion)"
84
+ obligation mandatory
85
+ }
86
+ characteristic fidelity_report {
87
+ type string
88
+ label "Twin-fidelity test report (the D2 evidence)"
89
+ obligation mandatory
90
+ }
91
+ characteristic surveillance_monitor {
92
+ type string
93
+ label "Surveillance monitor (the type-5 continuous half — validity is CONDITIONAL on it)"
94
+ obligation mandatory
95
+ }
96
+ characteristic type_certificate {
97
+ type string
98
+ label "Type certificate of the underlying instrument (the hard admission prerequisite, cited as provenance)"
99
+ obligation mandatory
100
+ }
101
+ characteristic probe_sources {
102
+ type string
103
+ label "Probe channels used (reference_instrument preferred; sim_ground_truth acceptance-only)"
104
+ obligation mandatory
105
+ }
106
+ characteristic traceability_limitation {
107
+ type string
108
+ label "Declared traceability limitation (observer-attestation evidence proves twin ≡ display, not twin ≡ mass)"
109
+ obligation optional
110
+ }
111
+ }
package/package.json CHANGED
@@ -1,6 +1,6 @@
1
1
  {
2
2
  "name": "@oimlsmart/primmel-packages",
3
- "version": "0.18.0",
3
+ "version": "0.20.0",
4
4
  "description": "The OIML SMART platform's authoritative model content: every Recommendation, the OIML-CS scheme, the CASCO foundations, the shared modules, and the product/program reference packages as Primmel (.prl) packages — the single source of truth the platform's data trees regenerate from. Consumed by the smart monorepo (oimlsmart/smart) at a pinned version (TODO.repos/02).",
5
5
  "type": "module",
6
6
  "repository": {