This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/oiml-r129/evaluation/certificate-template.prl +16 -0
- package/oiml-r129/execution/test-report-skeleton.prl +236 -0
- package/oiml-r144/evaluation/certificate-template.prl +22 -0
- package/oiml-r144/execution/test-report-skeleton.prl +254 -0
- package/oiml-r60/.primmel-allowlist.prl +6 -0
- package/oiml-r60/evaluation/certificate-template.prl +40 -0
- package/oiml-r60/execution/test-report-skeleton.prl +399 -0
- package/oiml-r91/evaluation/certificate-template.prl +17 -0
- package/oiml-r91/execution/test-report-skeleton.prl +426 -0
- package/oiml-twin-cert/evaluation/certificate-template.prl +111 -0
- package/package.json +1 -1
|
@@ -0,0 +1,426 @@
|
|
|
1
|
+
# OIML R 91 — test report skeleton (kernel 1.14.0's test_report_skeleton,
|
|
2
|
+
# TODO.roadmap/40): the R 91-3:2025 test report format — sections and the
|
|
3
|
+
# form inventory (C140 resolves the entries against the forms register).
|
|
4
|
+
# The R 91-4 type evaluation report is a separate document — its template
|
|
5
|
+
# is the evaluation-report family, not this register.
|
|
6
|
+
test_report_skeleton r91-3/test-report {
|
|
7
|
+
title "OIML R 91-3:2025 — Test report format for speed meters"
|
|
8
|
+
description "The complete test report for an OIML R 91 speed meter evaluation, structured per the R 91-3:2025 report format: the metrological field test, the laboratory programme per R 91-2, and the category-specific tests."
|
|
9
|
+
note "R 91-4 additionally defines the TYPE EVALUATION REPORT format — a separate document from the lab test report (R 91-3); its template is the evaluation-report family, not this register."
|
|
10
|
+
section 01 {
|
|
11
|
+
title "Metrological field test (OIML R 91-2, 4)"
|
|
12
|
+
form r91-3/report-1-1 {
|
|
13
|
+
file "01-01-field-test"
|
|
14
|
+
title "1.1 Traffic condition during measurement (metrological field test)"
|
|
15
|
+
conformance_test /conf/field/stationary-field-test
|
|
16
|
+
requirements { /req/metrological/mpe-stationary /req/metrological/measuring-intervals /req/metrological/indicated-speed /req/category-moving/stationary-mode }
|
|
17
|
+
required always
|
|
18
|
+
}
|
|
19
|
+
form r91-3/report-1-2 {
|
|
20
|
+
file "01-02-statistical-analysis"
|
|
21
|
+
title "1.2 Statistical analysis of errors (optional)"
|
|
22
|
+
conformance_test /conf/field/stationary-field-test
|
|
23
|
+
requirements { /req/metrological/mpe-stationary }
|
|
24
|
+
required conditional
|
|
25
|
+
notes "Optional per R 91-2, 4.7 — the statistical analysis is completed when the field-test error distribution warrants it."
|
|
26
|
+
}
|
|
27
|
+
form r91-3/report-1-3 {
|
|
28
|
+
file "01-03-image-evidence"
|
|
29
|
+
title "1.3 Assignment to image evidence"
|
|
30
|
+
conformance_test /conf/field/stationary-field-test
|
|
31
|
+
requirements { /req/metrological/vehicle-identification }
|
|
32
|
+
required always
|
|
33
|
+
}
|
|
34
|
+
}
|
|
35
|
+
section 02 {
|
|
36
|
+
title "Metrological laboratory tests by traffic simulation (OIML R 91-2, 5)"
|
|
37
|
+
form r91-3/report-2-1 {
|
|
38
|
+
file "02-01-dynamic-performance"
|
|
39
|
+
title "2.1 Dynamic performance test"
|
|
40
|
+
conformance_test /conf/field/dynamic-performance
|
|
41
|
+
requirements { /req/metrological/mpe-stationary /req/metrological/relevant-speed-values }
|
|
42
|
+
required always
|
|
43
|
+
}
|
|
44
|
+
form r91-3/report-2-2 {
|
|
45
|
+
file "02-02-speed-linearity"
|
|
46
|
+
title "2.2 Speed linearity test"
|
|
47
|
+
conformance_test /conf/linearities/speed-linearity
|
|
48
|
+
requirements { /req/metrological/linearity-limit }
|
|
49
|
+
required always
|
|
50
|
+
}
|
|
51
|
+
form r91-3/report-2-3 {
|
|
52
|
+
file "02-03-distance-linearity"
|
|
53
|
+
title "2.3 Distance linearity test"
|
|
54
|
+
conformance_test /conf/linearities/distance-linearity
|
|
55
|
+
requirements { /req/metrological/distance-angle-indication }
|
|
56
|
+
required always
|
|
57
|
+
}
|
|
58
|
+
form r91-3/report-2-4 {
|
|
59
|
+
file "02-04-angle-linearity"
|
|
60
|
+
title "2.4 Angle linearity test"
|
|
61
|
+
conformance_test /conf/linearities/angle-linearity
|
|
62
|
+
requirements { /req/metrological/distance-angle-indication }
|
|
63
|
+
required always
|
|
64
|
+
}
|
|
65
|
+
}
|
|
66
|
+
section 03 {
|
|
67
|
+
title "Influence factor and disturbance tests (OIML R 91-2, 6)"
|
|
68
|
+
form r91-3/report-3-1 {
|
|
69
|
+
file "03-01-dry-heat-operating"
|
|
70
|
+
title "3.1 Dry heat (operating)"
|
|
71
|
+
conformance_test /conf/influence/dry-heat-operating
|
|
72
|
+
requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
|
|
73
|
+
required always
|
|
74
|
+
}
|
|
75
|
+
form r91-3/report-3-2 {
|
|
76
|
+
file "03-02-dry-heat-storage"
|
|
77
|
+
title "3.2 Dry heat (storage)"
|
|
78
|
+
conformance_test /conf/disturbances/dry-heat-storage
|
|
79
|
+
requirements { /req/metrological/disturbances }
|
|
80
|
+
required always
|
|
81
|
+
}
|
|
82
|
+
form r91-3/report-3-3 {
|
|
83
|
+
file "03-03-cold-operating"
|
|
84
|
+
title "3.3 Cold (operating)"
|
|
85
|
+
conformance_test /conf/influence/cold-operating
|
|
86
|
+
requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
|
|
87
|
+
required always
|
|
88
|
+
}
|
|
89
|
+
form r91-3/report-3-4 {
|
|
90
|
+
file "03-04-cold-storage"
|
|
91
|
+
title "3.4 Cold (storage)"
|
|
92
|
+
conformance_test /conf/disturbances/cold-storage
|
|
93
|
+
requirements { /req/metrological/disturbances }
|
|
94
|
+
required always
|
|
95
|
+
}
|
|
96
|
+
form r91-3/report-3-5 {
|
|
97
|
+
file "03-05-damp-heat-cyclic"
|
|
98
|
+
title "3.5 Damp heat, cyclic (condensing)"
|
|
99
|
+
conformance_test /conf/influence/damp-heat-cyclic
|
|
100
|
+
requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
|
|
101
|
+
required always
|
|
102
|
+
}
|
|
103
|
+
form r91-3/report-3-6 {
|
|
104
|
+
file "03-06-water"
|
|
105
|
+
title "3.6 Water (optional)"
|
|
106
|
+
conformance_test /conf/disturbances/water
|
|
107
|
+
requirements { /req/metrological/disturbances }
|
|
108
|
+
required conditional
|
|
109
|
+
notes "Optional test (R 91-2, 6.1 Tables 1-2) — applied when relevant for the declared point of use and installation conditions."
|
|
110
|
+
}
|
|
111
|
+
form r91-3/report-3-7 {
|
|
112
|
+
file "03-07-sand-and-dust"
|
|
113
|
+
title "3.7 Sand and dust (optional)"
|
|
114
|
+
conformance_test /conf/disturbances/sand-and-dust
|
|
115
|
+
requirements { /req/metrological/disturbances }
|
|
116
|
+
required conditional
|
|
117
|
+
notes "Optional test (R 91-2, 6.1 Tables 1-2) — applied when relevant for the declared point of use and installation conditions."
|
|
118
|
+
}
|
|
119
|
+
form r91-3/report-3-8 {
|
|
120
|
+
file "03-08-salt-mist"
|
|
121
|
+
title "3.8 Salt mist (optional)"
|
|
122
|
+
conformance_test /conf/disturbances/salt-mist
|
|
123
|
+
requirements { /req/metrological/disturbances }
|
|
124
|
+
required conditional
|
|
125
|
+
notes "Optional test (R 91-2, 6.1 Table 1, row 6) — applied when relevant for the declared point of use and installation conditions."
|
|
126
|
+
}
|
|
127
|
+
form r91-3/report-3-9 {
|
|
128
|
+
file "03-09-vibration-random"
|
|
129
|
+
title "3.9 Vibration (random)"
|
|
130
|
+
conformance_test /conf/influence/vibration-random
|
|
131
|
+
requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
|
|
132
|
+
required always
|
|
133
|
+
}
|
|
134
|
+
form r91-3/report-3-10 {
|
|
135
|
+
file "03-10-mechanical-shock"
|
|
136
|
+
title "3.10 Mechanical shock"
|
|
137
|
+
conformance_test /conf/disturbances/mechanical-shock
|
|
138
|
+
requirements { /req/metrological/disturbances }
|
|
139
|
+
required always
|
|
140
|
+
}
|
|
141
|
+
form r91-3/report-3-11 {
|
|
142
|
+
file "03-11-dc-mains-voltage-variation"
|
|
143
|
+
title "3.11 DC mains voltage variation"
|
|
144
|
+
conformance_test /conf/influence/dc-mains-voltage-variation
|
|
145
|
+
requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
|
|
146
|
+
required always
|
|
147
|
+
}
|
|
148
|
+
form r91-3/report-3-12 {
|
|
149
|
+
file "03-12-ripple-on-dc-mains"
|
|
150
|
+
title "3.12 Ripple on DC mains power"
|
|
151
|
+
conformance_test /conf/disturbances/ripple-on-dc-mains
|
|
152
|
+
requirements { /req/metrological/disturbances }
|
|
153
|
+
required always
|
|
154
|
+
}
|
|
155
|
+
form r91-3/report-3-13 {
|
|
156
|
+
file "03-13-ac-mains-voltage-variation"
|
|
157
|
+
title "3.13 AC mains voltage variation"
|
|
158
|
+
conformance_test /conf/influence/ac-mains-voltage-variation
|
|
159
|
+
requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
|
|
160
|
+
required always
|
|
161
|
+
}
|
|
162
|
+
form r91-3/report-3-14 {
|
|
163
|
+
file "03-14-ac-mains-frequency-variation"
|
|
164
|
+
title "3.14 AC mains frequency variation"
|
|
165
|
+
conformance_test /conf/influence/ac-mains-frequency-variation
|
|
166
|
+
requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
|
|
167
|
+
required always
|
|
168
|
+
}
|
|
169
|
+
form r91-3/report-3-15 {
|
|
170
|
+
file "03-15-dc-mains-voltage-dips"
|
|
171
|
+
title "3.15 DC mains voltage dips, short interruptions and (short term) voltage variations"
|
|
172
|
+
conformance_test /conf/disturbances/dc-mains-voltage-dips
|
|
173
|
+
requirements { /req/metrological/disturbances }
|
|
174
|
+
required always
|
|
175
|
+
}
|
|
176
|
+
form r91-3/report-3-16 {
|
|
177
|
+
file "03-16-ac-mains-voltage-dips"
|
|
178
|
+
title "3.16 AC mains voltage dips, short interruptions and reductions"
|
|
179
|
+
conformance_test /conf/disturbances/ac-mains-voltage-dips
|
|
180
|
+
requirements { /req/metrological/disturbances }
|
|
181
|
+
required always
|
|
182
|
+
}
|
|
183
|
+
form r91-3/report-3-17 {
|
|
184
|
+
file "03-17-ac-mains-frequency-harmonics"
|
|
185
|
+
title "3.17 AC mains frequency harmonics"
|
|
186
|
+
conformance_test /conf/disturbances/ac-mains-frequency-harmonics
|
|
187
|
+
requirements { /req/metrological/disturbances }
|
|
188
|
+
required always
|
|
189
|
+
}
|
|
190
|
+
form r91-3/report-3-18 {
|
|
191
|
+
file "03-18-vlf-lf-disturbances"
|
|
192
|
+
title "3.18 VLF and LF disturbances on AC and DC mains"
|
|
193
|
+
conformance_test /conf/disturbances/vlf-lf-disturbances-ac-mains
|
|
194
|
+
requirements { /req/metrological/disturbances }
|
|
195
|
+
required always
|
|
196
|
+
}
|
|
197
|
+
form r91-3/report-3-19 {
|
|
198
|
+
file "03-19-bursts-ac-dc-mains"
|
|
199
|
+
title "3.19 Bursts (transients) on AC and DC mains"
|
|
200
|
+
conformance_test /conf/disturbances/bursts-ac-dc-mains
|
|
201
|
+
requirements { /req/metrological/disturbances }
|
|
202
|
+
required always
|
|
203
|
+
}
|
|
204
|
+
form r91-3/report-3-20 {
|
|
205
|
+
file "03-20-surges-ac-dc-mains"
|
|
206
|
+
title "3.20 Surges on AC and DC mains power lines"
|
|
207
|
+
conformance_test /conf/disturbances/surges-ac-dc-mains
|
|
208
|
+
requirements { /req/metrological/disturbances }
|
|
209
|
+
required always
|
|
210
|
+
}
|
|
211
|
+
form r91-3/report-3-21 {
|
|
212
|
+
file "03-21-bursts-signal-lines"
|
|
213
|
+
title "3.21 Bursts (transients) on signal, data and control lines"
|
|
214
|
+
conformance_test /conf/disturbances/bursts-signal-lines
|
|
215
|
+
requirements { /req/metrological/disturbances }
|
|
216
|
+
required always
|
|
217
|
+
}
|
|
218
|
+
form r91-3/report-3-22 {
|
|
219
|
+
file "03-22-surges-signal-lines"
|
|
220
|
+
title "3.22 Surges on signal, data and control lines"
|
|
221
|
+
conformance_test /conf/disturbances/surges-signal-lines
|
|
222
|
+
requirements { /req/metrological/disturbances }
|
|
223
|
+
required always
|
|
224
|
+
}
|
|
225
|
+
form r91-3/report-3-23 {
|
|
226
|
+
file "03-23-ac-mains-magnetic-field"
|
|
227
|
+
title "3.23 AC mains power frequency magnetic field"
|
|
228
|
+
conformance_test /conf/disturbances/ac-mains-power-frequency-magnetic-field
|
|
229
|
+
requirements { /req/metrological/disturbances }
|
|
230
|
+
required always
|
|
231
|
+
}
|
|
232
|
+
form r91-3/report-3-24 {
|
|
233
|
+
file "03-24-conducted-rf-common-mode"
|
|
234
|
+
title "3.24 Conducted (common mode) currents generated by RF electromagnetic fields"
|
|
235
|
+
conformance_test /conf/disturbances/conducted-rf-common-mode-currents
|
|
236
|
+
requirements { /req/metrological/disturbances }
|
|
237
|
+
required always
|
|
238
|
+
}
|
|
239
|
+
form r91-3/report-3-25 {
|
|
240
|
+
file "03-25-rf-electromagnetic-fields"
|
|
241
|
+
title "3.25 RF electromagnetic fields"
|
|
242
|
+
conformance_test /conf/disturbances/rf-electromagnetic-fields
|
|
243
|
+
requirements { /req/metrological/disturbances }
|
|
244
|
+
required always
|
|
245
|
+
}
|
|
246
|
+
form r91-3/report-3-26 {
|
|
247
|
+
file "03-26-electrostatic-discharges"
|
|
248
|
+
title "3.26 Electrostatic discharges"
|
|
249
|
+
conformance_test /conf/disturbances/electrostatic-discharges
|
|
250
|
+
requirements { /req/metrological/disturbances }
|
|
251
|
+
required always
|
|
252
|
+
}
|
|
253
|
+
form r91-3/report-3-27 {
|
|
254
|
+
file "03-27-internal-battery-low-voltage"
|
|
255
|
+
title "3.27 Low voltage of internal battery"
|
|
256
|
+
conformance_test /conf/influence/internal-battery-low-voltage
|
|
257
|
+
requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
|
|
258
|
+
required always
|
|
259
|
+
}
|
|
260
|
+
form r91-3/report-3-28 {
|
|
261
|
+
file "03-28-road-vehicle-battery"
|
|
262
|
+
title "3.28 Voltage variations of a road vehicle battery"
|
|
263
|
+
conformance_test /conf/influence/road-vehicle-battery-voltage-variations
|
|
264
|
+
requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
|
|
265
|
+
required always
|
|
266
|
+
}
|
|
267
|
+
form r91-3/report-3-29 {
|
|
268
|
+
file "03-29-transient-supply-lines"
|
|
269
|
+
title "3.29 Electrical transient conduction along supply lines of external 12 V and 24 V batteries"
|
|
270
|
+
conformance_test /conf/disturbances/transient-conduction-supply-lines
|
|
271
|
+
requirements { /req/metrological/disturbances }
|
|
272
|
+
required always
|
|
273
|
+
}
|
|
274
|
+
form r91-3/report-3-30 {
|
|
275
|
+
file "03-30-transient-other-lines"
|
|
276
|
+
title "3.30 Electrical transient conduction via lines other than supply lines for external 12 V and 24 V batteries"
|
|
277
|
+
conformance_test /conf/disturbances/transient-conduction-other-lines
|
|
278
|
+
requirements { /req/metrological/disturbances }
|
|
279
|
+
required always
|
|
280
|
+
}
|
|
281
|
+
form r91-3/report-3-31 {
|
|
282
|
+
file "03-31-battery-cranking"
|
|
283
|
+
title "3.31 Battery voltage variations during cranking"
|
|
284
|
+
conformance_test /conf/disturbances/battery-voltage-cranking
|
|
285
|
+
requirements { /req/metrological/disturbances }
|
|
286
|
+
required always
|
|
287
|
+
}
|
|
288
|
+
form r91-3/report-3-32 {
|
|
289
|
+
file "03-32-load-dump"
|
|
290
|
+
title "3.32 Load dump test"
|
|
291
|
+
conformance_test /conf/disturbances/load-dump
|
|
292
|
+
requirements { /req/metrological/disturbances }
|
|
293
|
+
required always
|
|
294
|
+
}
|
|
295
|
+
form r91-3/report-3-33 {
|
|
296
|
+
file "03-33-acceleration"
|
|
297
|
+
title "3.33 Acceleration test"
|
|
298
|
+
conformance_test /conf/field/acceleration-test
|
|
299
|
+
requirements { /req/metrological/mpe-stationary }
|
|
300
|
+
required always
|
|
301
|
+
}
|
|
302
|
+
form r91-3/report-3-34 {
|
|
303
|
+
file "03-34-further-influence"
|
|
304
|
+
title "3.34 Further influence quantity tests"
|
|
305
|
+
requirements { /req/metrological/linearity-limit }
|
|
306
|
+
required always
|
|
307
|
+
}
|
|
308
|
+
form r91-3/report-3-35 {
|
|
309
|
+
file "03-35-installation-alignment"
|
|
310
|
+
title "3.35 Installation and alignment of sensor and camera"
|
|
311
|
+
conformance_test /conf/linearities/alignment-misalignment
|
|
312
|
+
requirements { /req/category-across-road/alignment-error }
|
|
313
|
+
required always
|
|
314
|
+
}
|
|
315
|
+
}
|
|
316
|
+
section 04 {
|
|
317
|
+
title "Tests specific to certain categories of speed meters (OIML R 91-2, 7)"
|
|
318
|
+
form r91-3/report-4-1 {
|
|
319
|
+
file "04-01-doppler-radar"
|
|
320
|
+
title "4.1 Doppler-radar based speed meters"
|
|
321
|
+
requirements { /req/category-doppler-radar/beam-width /req/category-doppler-radar/frequency-spectrum /req/category-doppler-radar/spectrum-stability /req/category-doppler-radar/side-lobe }
|
|
322
|
+
required always
|
|
323
|
+
}
|
|
324
|
+
form r91-3/report-4-2 {
|
|
325
|
+
file "04-02-range-finding"
|
|
326
|
+
title "4.2 Range-finding based speed meters"
|
|
327
|
+
requirements { /req/category-range-finding/beam-width /req/category-range-finding/max-distance-viewfinder /req/category-range-finding/pulse-stability /req/category-range-finding/wavelength }
|
|
328
|
+
required always
|
|
329
|
+
}
|
|
330
|
+
form r91-3/report-4-3 {
|
|
331
|
+
file "04-03-average-speed"
|
|
332
|
+
title "4.3 Average speed meters"
|
|
333
|
+
requirements { /req/category-average-speed/detection-field-size /req/category-average-speed/time-synchronisation /req/category-average-speed/image-time-evidence }
|
|
334
|
+
required always
|
|
335
|
+
}
|
|
336
|
+
form r91-3/report-4-4 {
|
|
337
|
+
file "04-04-fixed-distance"
|
|
338
|
+
title "4.4 Fixed-distance speed meters"
|
|
339
|
+
requirements { /req/category-fixed-distance/detection-point-distance /req/category-fixed-distance/redundancy }
|
|
340
|
+
required always
|
|
341
|
+
}
|
|
342
|
+
form r91-3/report-4-5 {
|
|
343
|
+
file "04-05-image-based"
|
|
344
|
+
title "4.5 Image based speed meters"
|
|
345
|
+
conformance_test /conf/category-image-based/image-quality
|
|
346
|
+
requirements { /req/category-image-based/image-quality /req/category-image-based/position-marking /req/category-image-based/position-distances }
|
|
347
|
+
required always
|
|
348
|
+
}
|
|
349
|
+
form r91-3/report-4-6 {
|
|
350
|
+
file "04-06-across-road"
|
|
351
|
+
title "4.6 Across-the-road speed meters"
|
|
352
|
+
conformance_test /conf/examinations/across-road-examination
|
|
353
|
+
requirements { /req/category-across-road/reference-marking /req/category-across-road/cosine-verification }
|
|
354
|
+
required always
|
|
355
|
+
}
|
|
356
|
+
}
|
|
357
|
+
section 05 {
|
|
358
|
+
title "Moving speed meters (OIML R 91-2, 7.7)"
|
|
359
|
+
form r91-3/report-5-1 {
|
|
360
|
+
file "05-01-moving-field-test"
|
|
361
|
+
title "5.1 Moving metrological field test"
|
|
362
|
+
conformance_test /conf/field/moving-field-test
|
|
363
|
+
requirements { /req/category-moving/mpe-moving }
|
|
364
|
+
required always
|
|
365
|
+
}
|
|
366
|
+
form r91-3/report-5-2 {
|
|
367
|
+
file "05-02-ego-field-test"
|
|
368
|
+
title "5.2 Metrological field test of the ego speed meter"
|
|
369
|
+
conformance_test /conf/field/ego-field-test
|
|
370
|
+
requirements { /req/category-moving/ego-speed /req/category-moving/ego-adjustment }
|
|
371
|
+
required always
|
|
372
|
+
}
|
|
373
|
+
form r91-3/report-5-3 {
|
|
374
|
+
file "05-03-moving-traffic-simulation"
|
|
375
|
+
title "5.3 Traffic simulation for moving speed meters"
|
|
376
|
+
requirements { /req/category-moving/mpe-moving /req/category-moving/ego-speed }
|
|
377
|
+
required always
|
|
378
|
+
}
|
|
379
|
+
}
|
|
380
|
+
section 06 {
|
|
381
|
+
title "Software (OIML R 91-2, 8.3)"
|
|
382
|
+
form r91-3/report-6-1 {
|
|
383
|
+
file "06-01-software-general"
|
|
384
|
+
title "6.1 General requirements [mandatory]"
|
|
385
|
+
conformance_test /conf/software/software-examination
|
|
386
|
+
requirements { /req/technical/software }
|
|
387
|
+
required always
|
|
388
|
+
}
|
|
389
|
+
form r91-3/report-6-2 {
|
|
390
|
+
file "06-02-software-protection"
|
|
391
|
+
title "6.2 Software protection [mandatory]"
|
|
392
|
+
conformance_test /conf/software/software-examination
|
|
393
|
+
requirements { /req/technical/software }
|
|
394
|
+
required always
|
|
395
|
+
}
|
|
396
|
+
form r91-3/report-6-3 {
|
|
397
|
+
file "06-03-software-hardware-support"
|
|
398
|
+
title "6.3 Support of hardware features [mandatory]"
|
|
399
|
+
conformance_test /conf/software/software-examination
|
|
400
|
+
requirements { /req/technical/software }
|
|
401
|
+
required always
|
|
402
|
+
}
|
|
403
|
+
form r91-3/report-6-4 {
|
|
404
|
+
file "06-04-software-separation"
|
|
405
|
+
title "6.4 Specification and separation of legally relevant parts and specification of interfaces [optional]"
|
|
406
|
+
conformance_test /conf/software/software-examination
|
|
407
|
+
requirements { /req/technical/software }
|
|
408
|
+
required always
|
|
409
|
+
}
|
|
410
|
+
form r91-3/report-6-5 {
|
|
411
|
+
file "06-05-software-maintenance"
|
|
412
|
+
title "6.5 Maintenance and re-configuration [optional]"
|
|
413
|
+
conformance_test /conf/software/software-examination
|
|
414
|
+
requirements { /req/technical/software }
|
|
415
|
+
required always
|
|
416
|
+
}
|
|
417
|
+
}
|
|
418
|
+
section 07 {
|
|
419
|
+
title "General remarks"
|
|
420
|
+
form r91-3/report-general-remarks {
|
|
421
|
+
file "07-general-remarks"
|
|
422
|
+
title "General remarks"
|
|
423
|
+
required always
|
|
424
|
+
}
|
|
425
|
+
}
|
|
426
|
+
}
|
|
@@ -0,0 +1,111 @@
|
|
|
1
|
+
# oiml-twin-cert — TWIN CERTIFICATE TEMPLATE (TODO.v2/01 TCD-3;
|
|
2
|
+
# analysis/twin-certification-design.md Q3 "the certificate's claim").
|
|
3
|
+
#
|
|
4
|
+
# The twin certificate claims a SCOPED, CONDITIONAL relation (Q3): for
|
|
5
|
+
# instrument <model/serial>, the twin served at endpoint <endpoint-id> via
|
|
6
|
+
# operations <op-list> reflects the physical state of registers
|
|
7
|
+
# <aspect-list> within tolerance <δ per register> and freshness
|
|
8
|
+
# <fresh_within per register>, verified by probe schedule <schedule-id> on
|
|
9
|
+
# <date> (report <id>), with served-timestamp provenance declared
|
|
10
|
+
# (timestamp_fields). Validity is CONDITIONAL: continuous surveillance per
|
|
11
|
+
# monitor <monitor-id>; a sustained fail suspends; an unresolved fail
|
|
12
|
+
# withdraws.
|
|
13
|
+
#
|
|
14
|
+
# The characteristic rows are the claim's print projection. Every row
|
|
15
|
+
# resolves BY NAME from the certification decision's claim context
|
|
16
|
+
# (browser/src/services/twin-certificate.service.ts —
|
|
17
|
+
# twinCertificateCharacteristics): the twin's endpoint identity and the
|
|
18
|
+
# certified registers ride the decision evidence, never an entity-graph
|
|
19
|
+
# attribute (the program composes into nothing — there is no rec entity
|
|
20
|
+
# graph to bind, hence no attribute/dimension bindings on the rows).
|
|
21
|
+
# obligation: mandatory rows must carry a value on the issued certificate;
|
|
22
|
+
# the attestation-limitation row prints only when the probe evidence rode
|
|
23
|
+
# the attestation channel (controller decision 3: never silently upgraded).
|
|
24
|
+
#
|
|
25
|
+
# The certificate number format mirrors the Annex B shape with the
|
|
26
|
+
# program's own designators: TW-1 (the governing document,
|
|
27
|
+
# urn:oiml:pub:cs:twin-1:2027) / edition - T5 (the ISO/IEC 17067 scheme
|
|
28
|
+
# type the program self-classifies — type 5, surveillance-constitutive) -
|
|
29
|
+
# the scheme operator code - year.sequence.
|
|
30
|
+
#
|
|
31
|
+
# Row labels are the default-spelling (eng-Latn) content sets inline —
|
|
32
|
+
# the YAML twin re-wraps them as the Prose array the renderer resolves
|
|
33
|
+
# with src/data/prose.ts.
|
|
34
|
+
certificate_template certificate {
|
|
35
|
+
number_format "TW-1/{edition}-T5-{authority}-{year2}.{seq}"
|
|
36
|
+
characteristic instrument_model {
|
|
37
|
+
type string
|
|
38
|
+
label "Instrument model (the underlying certified type)"
|
|
39
|
+
obligation mandatory
|
|
40
|
+
}
|
|
41
|
+
characteristic instrument_serial {
|
|
42
|
+
type string
|
|
43
|
+
label "Instrument serial number (the certified unit — per-UNIT certification, type 5)"
|
|
44
|
+
obligation mandatory
|
|
45
|
+
}
|
|
46
|
+
characteristic twin_endpoint {
|
|
47
|
+
type string
|
|
48
|
+
label "Twin endpoint identifier (bound to the certified unit's serial)"
|
|
49
|
+
obligation mandatory
|
|
50
|
+
}
|
|
51
|
+
characteristic served_operations {
|
|
52
|
+
type string
|
|
53
|
+
label "Served operations certified"
|
|
54
|
+
obligation mandatory
|
|
55
|
+
}
|
|
56
|
+
characteristic fidelity_registers {
|
|
57
|
+
type string
|
|
58
|
+
label "Fidelity registers certified (served aspects)"
|
|
59
|
+
obligation mandatory
|
|
60
|
+
}
|
|
61
|
+
characteristic twin_tolerance_indication {
|
|
62
|
+
type string
|
|
63
|
+
label "Twin tolerance δ_indication (|served − reference| ≤ δ at every probe point)"
|
|
64
|
+
obligation mandatory
|
|
65
|
+
}
|
|
66
|
+
characteristic fresh_within_indication {
|
|
67
|
+
type string
|
|
68
|
+
label "Freshness window — indication register (fresh_within)"
|
|
69
|
+
obligation mandatory
|
|
70
|
+
}
|
|
71
|
+
characteristic fresh_within_op_state {
|
|
72
|
+
type string
|
|
73
|
+
label "Freshness window — state register (fresh_within)"
|
|
74
|
+
obligation mandatory
|
|
75
|
+
}
|
|
76
|
+
characteristic probe_schedule {
|
|
77
|
+
type string
|
|
78
|
+
label "Probe schedule (the certification's executable — range, envelope, transitions)"
|
|
79
|
+
obligation mandatory
|
|
80
|
+
}
|
|
81
|
+
characteristic verified_on {
|
|
82
|
+
type string
|
|
83
|
+
label "Verification date (the probe campaign's completion)"
|
|
84
|
+
obligation mandatory
|
|
85
|
+
}
|
|
86
|
+
characteristic fidelity_report {
|
|
87
|
+
type string
|
|
88
|
+
label "Twin-fidelity test report (the D2 evidence)"
|
|
89
|
+
obligation mandatory
|
|
90
|
+
}
|
|
91
|
+
characteristic surveillance_monitor {
|
|
92
|
+
type string
|
|
93
|
+
label "Surveillance monitor (the type-5 continuous half — validity is CONDITIONAL on it)"
|
|
94
|
+
obligation mandatory
|
|
95
|
+
}
|
|
96
|
+
characteristic type_certificate {
|
|
97
|
+
type string
|
|
98
|
+
label "Type certificate of the underlying instrument (the hard admission prerequisite, cited as provenance)"
|
|
99
|
+
obligation mandatory
|
|
100
|
+
}
|
|
101
|
+
characteristic probe_sources {
|
|
102
|
+
type string
|
|
103
|
+
label "Probe channels used (reference_instrument preferred; sim_ground_truth acceptance-only)"
|
|
104
|
+
obligation mandatory
|
|
105
|
+
}
|
|
106
|
+
characteristic traceability_limitation {
|
|
107
|
+
type string
|
|
108
|
+
label "Declared traceability limitation (observer-attestation evidence proves twin ≡ display, not twin ≡ mass)"
|
|
109
|
+
obligation optional
|
|
110
|
+
}
|
|
111
|
+
}
|
package/package.json
CHANGED
|
@@ -1,6 +1,6 @@
|
|
|
1
1
|
{
|
|
2
2
|
"name": "@oimlsmart/primmel-packages",
|
|
3
|
-
"version": "0.
|
|
3
|
+
"version": "0.20.0",
|
|
4
4
|
"description": "The OIML SMART platform's authoritative model content: every Recommendation, the OIML-CS scheme, the CASCO foundations, the shared modules, and the product/program reference packages as Primmel (.prl) packages — the single source of truth the platform's data trees regenerate from. Consumed by the smart monorepo (oimlsmart/smart) at a pinned version (TODO.repos/02).",
|
|
5
5
|
"type": "module",
|
|
6
6
|
"repository": {
|