@ncd-io/node-red-enterprise-sensors 1.6.4 → 2.0.0

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
package/wireless.html CHANGED
@@ -581,9 +581,9 @@
581
581
 
582
582
  push_notification_108_active:{value: ""},
583
583
  push_notification_108: {value: 0},
584
- push_notification_33_active:{value: ""},
585
- push_notification_33:{value: 0},
586
- clear_counter_33:{value:0},
584
+ // push_notification_33_active:{value: ""},
585
+ // push_notification_33:{value: 0},
586
+ // clear_counter_33:{value:0},
587
587
  input_two_33:{value:1},
588
588
  input_two_33_active:{value:""},
589
589
 
@@ -773,7 +773,7 @@
773
773
  adxl_fsr_103_active: {value: ""},
774
774
  adxl_fsr_103: {value: 0},
775
775
  sampling_duration_103_active: {value: ""},
776
- sampling_duration_103: {value: 20, validate: NCD_validators.number_range(1, 20)},
776
+ sampling_duration_103: {value: 20, validate: NCD_validators.number_range(1, 255)},
777
777
  debounce_time_123: {value:10, validate: NCD_validators.number_range(10, 65000)},
778
778
  debounce_time_123_active: {value:""},
779
779
  debounce_time_v10_108: {value:10, validate: NCD_validators.number_range(10, 65000)},
@@ -798,8 +798,8 @@
798
798
 
799
799
  push_notification_123_active: {value: ""},
800
800
  push_notification_123: {value:0},
801
- clear_timers_123_active: {value: ""},
802
- clear_timers_123: {value:7},
801
+ // clear_timers_123_active: {value: ""},
802
+ // clear_timers_123: {value:7},
803
803
  input_one_123_active: {value: ""},
804
804
  input_one_123: {value:1},
805
805
  input_two_123_active: {value: ""},
@@ -970,7 +970,33 @@
970
970
  factory_reset_sensor_99_active: {value:""},
971
971
 
972
972
  calibration_factor_217_active: {value:""},
973
- calibration_factor_217: {value: 135, validate: NCD_validators.number_range(0, 500000)}
973
+ calibration_factor_217: {value: 135, validate: NCD_validators.number_range(0, 500000)},
974
+
975
+ clear_timers_35:{value:0},
976
+ push_notification_35_active:{value:""},
977
+ push_notification_35:{value: 0},
978
+ interrupt_timeout_35_active:{value:""},
979
+ interrupt_timeout_35:{value: 0, validate: NCD_validators.number_range(0, 65535)},
980
+ counter_threshold_35_gen2_active:{value:""},
981
+ counter_threshold_35_gen2:{value: 0, validate: NCD_validators.number_range(0, 65535)},
982
+
983
+ push_notification_125_active:{value:""},
984
+ push_notification_125:{value: 0},
985
+ probe_one_126_active:{value:""},
986
+ probe_one_126:{value: 0},
987
+ probe_two_126_active:{value:""},
988
+ probe_two_126:{value: 0},
989
+ probe_three_126_active:{value:""},
990
+ probe_three_126:{value: 0},
991
+ threshold_probe_one_126_active:{value:""},
992
+ threshold_probe_one_126:{value: 3, validate: NCD_validators.number_range(0, 65535)},
993
+ threshold_probe_two_126_active:{value:""},
994
+ threshold_probe_two_126:{value: 3, validate: NCD_validators.number_range(0, 65535)},
995
+ threshold_probe_three_126_active:{value:""},
996
+ threshold_probe_three_126:{value: 3, validate: NCD_validators.number_range(0, 65535)},
997
+
998
+ send_raw_on_motion_only_103_active:{value:""},
999
+ send_raw_on_motion_only_103:{value: 0}
974
1000
  },
975
1001
  inputs: 0,
976
1002
  outputs: 1,
@@ -1037,7 +1063,7 @@
1037
1063
  "60": "60 - Air Velocity, Pressure, & Temperature Sensor",
1038
1064
  "61": "61 - pH Temperature Sensor",
1039
1065
  "62": "62 - ORP Temperature Sensor",
1040
- "63": "63 - pH and ORPTemperature Sensor",
1066
+ "63": "63 - pH and ORP Temperature Sensor",
1041
1067
  "64": "64 - EC Salinity TDS and Temperature Sensor",
1042
1068
  "65": "65 - DO and Temperature Sensor",
1043
1069
  "66": "66 - DO EC Salinity TDS and Temperature Sensor",
@@ -1062,6 +1088,7 @@
1062
1088
  "90": "90 - DC Current Sensor",
1063
1089
  "91": "91 - Wireless Air Velocity Sensor HVAC",
1064
1090
  "92": "92 - Sound Sensor",
1091
+ "93": "93 - Oil Temperature and Moisture Sensor",
1065
1092
  "95": "95 - 16-Bit 1-Channel 0-24VDC Receiver",
1066
1093
  "96": "96 - 16-Bit 1-Channel 0-48VDC Receiver",
1067
1094
  "97": "97 - One channel Dynamic Ultrasound vibration Sensor",
@@ -1087,6 +1114,9 @@
1087
1114
  "122": "122 - Wireless 4-20mA Current Splitter",
1088
1115
  "123": "123 - 3 Channel Production Counter",
1089
1116
  "124": "124 - Wireless EH Flow Sensor",
1117
+ "125": "125 - 2 Channel OEE AC Current Production Monitor Sensor",
1118
+ "126": "126 - 3 Channel OEE AC Current Production Monitor Sensor",
1119
+ "128": "128 - Wireless Water Detect Sensor",
1090
1120
  "180": "180 - C1D2 One Channel Vibration Plus",
1091
1121
  "181": "181 - C1D2 Two Channel Vibration Plus",
1092
1122
  "200": "200 - 4-20mA Pass Through",
@@ -1116,6 +1146,7 @@
1116
1146
  "542": "542 - Custom LWGY Flow Sensor",
1117
1147
  "543": "543 - Custom Seismic Vibration Sensor",
1118
1148
  "545": "545 - Fox Thermal Flow Sensor",
1149
+ "554": "554 - Custom 400-50,000 PPM CO2 Sensor",
1119
1150
  "1010": "1010 - RS232 Wireless Converter 1010",
1120
1151
  "1011": "1011 - RS485 Wireless Converter 1011",
1121
1152
  "10000": "10000 - 4-Channel Relay",
@@ -1356,7 +1387,7 @@
1356
1387
  <option value="60">60 - Air Velocity and Precision Pressure & Temperature Sensor</option>
1357
1388
  <option value="61">61 - pH Temperature Sensor</option>
1358
1389
  <option value="62">62 - ORP Temperature Sensor</option>
1359
- <option value="63">63 - pH and ORPTemperature Sensor</option>
1390
+ <option value="63">63 - pH and ORP Temperature Sensor</option>
1360
1391
  <option value="64">64 - EC Salinity TDS and Temperature Sensor</option>
1361
1392
  <option value="65">65 - DO and Temperature Sensor</option>
1362
1393
  <option value="66">66 - DO EC Salinity TDS and Temperature Sensor</option>
@@ -1383,6 +1414,7 @@
1383
1414
  <option value="90">90 - DC Current Sensor</option>
1384
1415
  <option value="91">91 - Wireless Air Velocity Sensor HVAC</option>
1385
1416
  <option value="92">92 - Sound Sensor</option>
1417
+ <option value="93">93 - Oil Temperature and Moisture Sensor</option>
1386
1418
  <option value="95">95 - 16-Bit 1-Channel 0-24VDC Receiver</option>
1387
1419
  <option value="96">96 - 16-Bit 1-Channel 0-48VDC Receiver</option>
1388
1420
  <option value="97">97 - One channel Dynamic Ultrasound vibration Sensor</option>
@@ -1408,6 +1440,9 @@
1408
1440
  <option value="122">122 - Wireless 4-20mA Current Splitter</option>
1409
1441
  <option value="123">123 - 3 Channel Production Counter</option>
1410
1442
  <option value="124">124 - Wireless EH Flow Sensor</option>
1443
+ <option value="125">125 - 2 Channel OEE AC Current Production Monitor Sensor</option>
1444
+ <option value="126">126 - 3 Channel OEE AC Current Production Monitor Sensor</option>
1445
+ <option value="128">128 - Wireless Water Detect Sensor</option>
1411
1446
  <option value="180">180 - C1D2 One Channel Vibration Plus</option>
1412
1447
  <option value="181">181 - C1D2 Two Channel Vibration Plus</option>
1413
1448
  <option value="200">200 - 4-20mA Pass Through</option>
@@ -1437,6 +1472,7 @@
1437
1472
  <option value="542">542 - Custom LWGY Flow Sensor</option>
1438
1473
  <option value="543">543 - Custom Seismic Vibration Sensor</option>
1439
1474
  <option value="545">545 - Fox Thermal Flow Sensor</option>
1475
+ <option value="554">554 - Custom 400-50,000 PPM CO2 Sensor</option>
1440
1476
  <option value="1010">1010 - RS232 Wireless Converter 1010</option>
1441
1477
  <option value="1011">1011 - RS485 Wireless Converter 1011</option>
1442
1478
  <option value="10000">10000 - 4-Channel Relay</option>
@@ -1452,7 +1488,7 @@
1452
1488
  <label for="node-input-auto_config"><i class="icon-tag"></i> Auto Config</label>
1453
1489
  <input class="section-control" type="checkbox" id="node-input-auto_config" value="1">
1454
1490
  </div>
1455
- <div class="form-row ncd-dependent" data-sensor-4 data-sensor-12 data-sensor-21 data-sensor-29 data-sensor-23 data-sensor-26 data-sensor-32 data-sensor-33 data-sensor-39 data-sensor-44 data-sensor-45 data-sensor-48 data-sensor-52 data-sensor-53 data-sensor-54 data-sensor-55 data-sensor-56 data-sensor-58 data-sensor-74 data-sensor-76 data-sensor-78 data-sensor-79 data-sensor-80 data-sensor-81 data-sensor-82 data-sensor-84 data-sensor-87 data-sensor-88 data-sensor-89 data-sensor-90 data-sensor-91 data-sensor-97 data-sensor-98 data-sensor-99 data-sensor-101 data-sensor-102 data-sensor-103 data-sensor-105 data-sensor-106 data-sensor-107 data-sensor-108 data-sensor-109 data-sensor-110 data-sensor-111 data-sensor-112 data-sensor-114 data-sensor-117 data-sensor-118 data-sensor-119 data-sensor-120 data-sensor-121 data-sensor-122 data-sensor-123 data-sensor-124 data-sensor-180 data-sensor-181 data-sensor-202 data-sensor-211 data-sensor-217 data-sensor-270 data-sensor-519 data-sensor-520 data-sensor-521 data-sensor-531 data-sensor-535 data-sensor-536 data-sensor-537 data-sensor-538 data-sensor-539 data-sensor-540 data-sensor-541 data-sensor-542 data-sensor-543 data-sensor-545 data-sensor-1010 data-sensor-1011>
1491
+ <div class="form-row ncd-dependent" data-sensor-4 data-sensor-12 data-sensor-21 data-sensor-29 data-sensor-23 data-sensor-26 data-sensor-30 data-sensor-32 data-sensor-33 data-sensor-35 data-sensor-39 data-sensor-44 data-sensor-45 data-sensor-48 data-sensor-52 data-sensor-53 data-sensor-54 data-sensor-55 data-sensor-56 data-sensor-58 data-sensor-74 data-sensor-76 data-sensor-78 data-sensor-79 data-sensor-80 data-sensor-81 data-sensor-82 data-sensor-84 data-sensor-87 data-sensor-88 data-sensor-89 data-sensor-90 data-sensor-91 data-sensor-93 data-sensor-97 data-sensor-98 data-sensor-99 data-sensor-101 data-sensor-102 data-sensor-103 data-sensor-105 data-sensor-106 data-sensor-107 data-sensor-108 data-sensor-109 data-sensor-110 data-sensor-111 data-sensor-112 data-sensor-114 data-sensor-117 data-sensor-118 data-sensor-119 data-sensor-120 data-sensor-121 data-sensor-122 data-sensor-123 data-sensor-124 data-sensor-125 data-sensor-126 data-sensor-128 data-sensor-180 data-sensor-181 data-sensor-202 data-sensor-211 data-sensor-217 data-sensor-270 data-sensor-519 data-sensor-520 data-sensor-521 data-sensor-531 data-sensor-535 data-sensor-536 data-sensor-537 data-sensor-538 data-sensor-539 data-sensor-540 data-sensor-541 data-sensor-542 data-sensor-543 data-sensor-545 data-sensor-554 data-sensor-1010 data-sensor-1011>
1456
1492
  <hr>
1457
1493
  <label for="node-input-on_the_fly_enable"><i class="icon-tag"></i> OTF Config*</label>
1458
1494
  <input type="checkbox" id="node-input-on_the_fly_enable" value="1">
@@ -1644,6 +1680,12 @@
1644
1680
  <div class="ncd-dependent" data-sensor-3 data-sensor-10 data-sensor-13 data-sensor-19 data-sensor-28>
1645
1681
  <div class="form-row ncd-active-check">
1646
1682
  <strong>Percentage Change Detection - Channel 1</strong>
1683
+ <p class="caption">Enable Checkbox:<br>
1684
+ Selected: The Percentage Change Detection function will be activated following the next sensor configuration.<br>
1685
+ Deselected: The Percentage Change Detection function will be deactivated following the next sensor configuration.<br><br>
1686
+ Percentage Change Threshold: This value defines the percentage difference required to trigger a transmission. The sensor will send an immediate message when the difference between two consecutive readings meets or exceeds this set percentage.<br><br>
1687
+ Percentage Change Interval: This setting defines the frequency at which the sensor samples data to evaluate the percentage change. The sensor compares the current sample against the previous one at every interval to determine if the threshold has been met.
1688
+ </p>
1647
1689
  <div>
1648
1690
  <label for="node-input-change_detection_t3_active">Active:</label>
1649
1691
  <input type="checkbox" id="node-input-change_detection_t3_active" class="ncd-config-toggle" data-target-class="change_detection_t3" value="1">
@@ -1665,6 +1707,12 @@
1665
1707
  <div class="ncd-dependent" data-sensor-28 data-sensor-19>
1666
1708
  <div class="form-row ncd-active-check">
1667
1709
  <strong>Percentage Change Detection - Channel 2</strong>
1710
+ <p class="caption">Enable Checkbox:<br>
1711
+ Selected: The Percentage Change Detection function will be activated following the next sensor configuration.<br>
1712
+ Deselected: The Percentage Change Detection function will be deactivated following the next sensor configuration.<br><br>
1713
+ Percentage Change Threshold: This value defines the percentage difference required to trigger a transmission. The sensor will send an immediate message when the difference between two consecutive readings meets or exceeds this set percentage.<br><br>
1714
+ Percentage Change Interval: This setting defines the frequency at which the sensor samples data to evaluate the percentage change. The sensor compares the current sample against the previous one at every interval to determine if the threshold has been met.
1715
+ </p>
1668
1716
  <div>
1669
1717
  <label for="node-input-change_detection_ch2_active">Active:</label>
1670
1718
  <input type="checkbox" id="node-input-change_detection_ch2_active" class="ncd-config-toggle" data-target-class="change_detection_ch2" value="1">
@@ -1686,6 +1734,12 @@
1686
1734
  <div class="ncd-dependent" data-sensor-28>
1687
1735
  <div class="form-row ncd-active-check">
1688
1736
  <strong>Percentage Change Detection - Channel 3</strong>
1737
+ <p class="caption">Enable Checkbox:<br>
1738
+ Selected: The Percentage Change Detection function will be activated following the next sensor configuration.<br>
1739
+ Deselected: The Percentage Change Detection function will be deactivated following the next sensor configuration.<br><br>
1740
+ Percentage Change Threshold: This value defines the percentage difference required to trigger a transmission. The sensor will send an immediate message when the difference between two consecutive readings meets or exceeds this set percentage.<br><br>
1741
+ Percentage Change Interval: This setting defines the frequency at which the sensor samples data to evaluate the percentage change. The sensor compares the current sample against the previous one at every interval to determine if the threshold has been met.
1742
+ </p>
1689
1743
  <div>
1690
1744
  <label for="node-input-change_detection_ch3_active">Active:</label>
1691
1745
  <input type="checkbox" id="node-input-change_detection_ch3_active" class="ncd-config-toggle" data-target-class="change_detection_ch3" value="1">
@@ -2601,7 +2655,7 @@
2601
2655
  </div>
2602
2656
  </div>
2603
2657
 
2604
- <div class="ncd-dependent" data-sensor-78 data-sensor-79 data-sensor-91>
2658
+ <div class="ncd-dependent" data-sensor-78 data-sensor-79 data-sensor-91 data-sensor-93>
2605
2659
  <div class="form-row ncd-active-check">
2606
2660
  <strong>Sensor Boot Time</strong>
2607
2661
  <p class="caption">
@@ -2823,12 +2877,12 @@
2823
2877
  </div>
2824
2878
  </div>
2825
2879
  </div>
2826
- <div class="ncd-dependent" data-sensor-33>
2880
+ <!-- <div class="ncd-dependent" data-sensor-33>
2827
2881
  <div class="form-row ncd-active-check">
2828
2882
  <label for="node-input-clear_counter_33"><i class="icon-tag"></i>Clear Counter Value</label>
2829
2883
  <input type="checkbox" id="node-input-clear_counter_33" value="1">
2830
2884
  </div>
2831
- </div>
2885
+ </div> -->
2832
2886
  <div class="ncd-dependent" data-sensor-108>
2833
2887
  <div class="form-row ncd-active-check">
2834
2888
  <strong>Clear Counters</strong>
@@ -2905,21 +2959,68 @@
2905
2959
  </div>
2906
2960
  </div>
2907
2961
  </div>
2908
- <div class="ncd-dependent" data-sensor-123>
2962
+ <div class="ncd-dependent" data-sensor-35 data-sensor-36>
2963
+ <hr>
2964
+ <div class="form-row ncd-active-check">
2965
+ <strong>Counter Threshold (Gen1)</strong>
2966
+ <p class="caption">
2967
+ The sensor will transmit data when any connected counter reaches a multiple of this threshold value.<br><br>
2968
+ **Applies to sensor with firmware version 9 and below (Gen1).
2969
+ <br>
2970
+ <br>
2971
+ Note: The range for this value is from 0 to 65534 and must be multiple of 100.
2972
+ </p>
2973
+ <div>
2974
+ <label for="node-input-counter_threshold_35_active">Active:</label>
2975
+ <input type="checkbox" id="node-input-counter_threshold_35_active" class="ncd-config-toggle" data-target-id="node-input-counter_threshold_35" value="1">
2976
+ </div>
2977
+ <div>
2978
+ <label for="node-input-counter_threshold_35"><i class="icon-tag"></i>Value:</label>
2979
+ <input type="text" id="node-input-counter_threshold_35" placeholder="50" value="50">
2980
+ </div>
2981
+ <p class="caption">
2982
+ Default value: Disabled (0).
2983
+ </p>
2984
+ </div>
2985
+ </div>
2986
+ <div class="ncd-dependent" data-sensor-2 data-sensor-35 data-sensor-36>
2987
+ <div class="form-row ncd-active-check">
2988
+ <strong>Set Input Debounce Time (Gen1)</strong>
2989
+ <p class="caption">
2990
+ Sets the debounce time in milliseconds on inputs. State changes to the input during this debounce time will be ignored. Generally recommended for mechanically triggered state changes such as button or relay/contactor outputs.<br><br>
2991
+ **Applies to sensor with firmware version 9 and below (Gen1).
2992
+ </p>
2993
+ <div>
2994
+ <label for="node-input-debounce_time_2_active">Active:</label>
2995
+ <input type="checkbox" id="node-input-debounce_time_2_active" class="ncd-config-toggle" data-target-id="node-input-debounce_time_2" value="1">
2996
+ </div>
2997
+ <div>
2998
+ <label for="node-input-debounce_time_2"><i class="icon-tag"></i>Value:</label>
2999
+ <input type="text" id="node-input-debounce_time_2" placeholder="10" value="10">
3000
+ </div>
3001
+ </div>
3002
+ <hr>
3003
+ <div class="form-row ncd-active-check">
3004
+ <strong>**The following settings are compatible only with sensors running firmware version 10 or higher (Gen 2).</strong>
3005
+ </div>
3006
+ </div>
3007
+ <div class="ncd-dependent" data-sensor-123 data-sensor-125 data-sensor-126>
2909
3008
  <div class="form-row ncd-active-check">
2910
3009
  <strong>Clear Counters</strong>
2911
3010
  <p class="caption">
2912
- Resets the Digital Inputs 1, 2, and 3 counters and their corresponding uptime values to zero.
3011
+ Resets all the Inputs Counters and their corresponding Uptime values to zero in the next sensor configuration.
2913
3012
  </p>
2914
3013
  <div>
2915
3014
  <label for="node-input-clear_timers_123_active">Active:</label>
2916
3015
  <input type="checkbox" id="node-input-clear_timers_123_active" class="ncd-config-toggle" data-target-id="node-input-clear_timers_123" value="1">
2917
3016
  </div>
2918
3017
  <div>
2919
- <label for="node-input-clear_timers_123"><i class="icon-tag"></i>Value:</label>
3018
+ <label for="node-input-clear_timers_123"><i class="icon-tag"></i>Active:</label>
3019
+ <input type="checkbox" id="node-input-clear_timers_123" value="1">
3020
+ <!-- <label for="node-input-clear_timers_123"><i class="icon-tag"></i>Value:</label>
2920
3021
  <select id="node-input-clear_timers_123">
2921
3022
  <option value="7" selected>Enable</option>
2922
- </select>
3023
+ </select> -->
2923
3024
  </div>
2924
3025
  </div>
2925
3026
  </div>
@@ -2960,7 +3061,7 @@
2960
3061
  </div>
2961
3062
  <div class="ncd-dependent" data-sensor-33>
2962
3063
  <div class="form-row ncd-active-check">
2963
- <strong>Set Contact Closure Detection</strong>
3064
+ <strong>Set Input Detection</strong>
2964
3065
  <div>
2965
3066
  <label for="node-input-input_two_33_active">Active:</label>
2966
3067
  <input type="checkbox" id="node-input-input_two_33_active" class="ncd-config-toggle" data-target-id="node-input-input_two_33" value="1">
@@ -2973,7 +3074,7 @@
2973
3074
  </select>
2974
3075
  </div>
2975
3076
  </div>
2976
- <div class="form-row ncd-active-check">
3077
+ <!-- <div class="form-row ncd-active-check">
2977
3078
  <strong>Enable Push Notification</strong>
2978
3079
  <div>
2979
3080
  <label for="node-input-push_notification_33_active">Active:</label>
@@ -2986,7 +3087,7 @@
2986
3087
  <option value="2">Enable</option>
2987
3088
  </select>
2988
3089
  </div>
2989
- </div>
3090
+ </div> -->
2990
3091
  </div>
2991
3092
  <div class="ncd-dependent" data-sensor-108>
2992
3093
  <div class="form-row ncd-active-check">
@@ -3047,11 +3148,11 @@
3047
3148
  </div>
3048
3149
  </div>
3049
3150
  </div>
3050
- <div class="ncd-dependent" data-sensor-123>
3151
+ <div class="ncd-dependent" data-sensor-33 data-sensor-35 data-sensor-123 data-sensor-125 data-sensor-126>
3051
3152
  <div class="form-row ncd-active-check">
3052
3153
  <strong>Set Input Debounce Time</strong>
3053
3154
  <p class="caption">
3054
- Configures the debounce time in milliseconds for all digital inputs. State changes occurring within this debounce period will be ignored.<br>
3155
+ Configures the debounce time in milliseconds for all inputs. State changes occurring within this debounce period will be ignored.<br>
3055
3156
  Note: This setting is recommended for mechanically triggered inputs like buttons or relay/contactor outputs.<br><br>
3056
3157
  Range: 10 - 65000msec.
3057
3158
  </p>
@@ -3063,11 +3164,16 @@
3063
3164
  <label for="node-input-debounce_time_123"><i class="icon-tag"></i>Value:</label>
3064
3165
  <input type="text" id="node-input-debounce_time_123" placeholder="10" value="10">
3065
3166
  </div>
3167
+ <p class="caption">
3168
+ Default value: 10 milliseconds.
3169
+ </p>
3066
3170
  </div>
3171
+ </div>
3172
+ <div class="ncd-dependent" data-sensor-35 data-sensor-123 data-sensor-125 data-sensor-126>
3067
3173
  <div class="form-row ncd-active-check">
3068
- <strong>Set Digital Input 1 Detection</strong>
3174
+ <strong>Set Input 1 Detection</strong>
3069
3175
  <p>
3070
- Configures how the counter increments and how uptime is calculated for Digital Input 1:<br><br>
3176
+ Configures how the counter increments and how uptime is calculated for Input 1:<br><br>
3071
3177
  Rising Edge: The counter increments, and uptime is calculated, when the input transitions from LOW to HIGH (active HIGH).<br>
3072
3178
  Falling Edge: The counter increments, and uptime is calculated, when the input transitions from HIGH to LOW (active LOW).
3073
3179
  </p>
@@ -3082,11 +3188,16 @@
3082
3188
  <option value="1" selected>Rising Edge Trigger</option>
3083
3189
  </select>
3084
3190
  </div>
3191
+ <p class="caption">
3192
+ Default value: Falling Edge.
3193
+ </p>
3085
3194
  </div>
3195
+ </div>
3196
+ <div class="ncd-dependent" data-sensor-123 data-sensor-125 data-sensor-126>
3086
3197
  <div class="form-row ncd-active-check">
3087
- <strong>Set Digital Input 2 Detection</strong>
3198
+ <strong>Set Input 2 Detection</strong>
3088
3199
  <p>
3089
- Configures how the counter increments and how uptime is calculated for Digital Input 2:<br><br>
3200
+ Configures how the counter increments and how uptime is calculated for Input 2:<br><br>
3090
3201
  Rising Edge: The counter increments, and uptime is calculated, when the input transitions from LOW to HIGH (active HIGH).<br>
3091
3202
  Falling Edge: The counter increments, and uptime is calculated, when the input transitions from HIGH to LOW (active LOW).
3092
3203
  </p>
@@ -3101,11 +3212,16 @@
3101
3212
  <option value="1" selected>Rising Edge Trigger</option>
3102
3213
  </select>
3103
3214
  </div>
3215
+ <p class="caption">
3216
+ Default value: Falling Edge.
3217
+ </p>
3104
3218
  </div>
3219
+ </div>
3220
+ <div class="ncd-dependent" data-sensor-123 data-sensor-126>
3105
3221
  <div class="form-row ncd-active-check">
3106
- <strong>Set Digital Input 3 Detection</strong>
3222
+ <strong>Set Input 3 Detection</strong>
3107
3223
  <p>
3108
- Configures how the counter increments and how uptime is calculated for Digital Input 3:<br><br>
3224
+ Configures how the counter increments and how uptime is calculated for Input 3:<br><br>
3109
3225
  Rising Edge: The counter increments, and uptime is calculated, when the input transitions from LOW to HIGH (active HIGH).<br>
3110
3226
  Falling Edge: The counter increments, and uptime is calculated, when the input transitions from HIGH to LOW (active LOW).
3111
3227
  </p>
@@ -3120,9 +3236,12 @@
3120
3236
  <option value="1" selected>Rising Edge Trigger</option>
3121
3237
  </select>
3122
3238
  </div>
3239
+ <p class="caption">
3240
+ Default value: Falling Edge.
3241
+ </p>
3123
3242
  </div>
3124
3243
  </div>
3125
- <div class="ncd-dependent" data-sensor-33 data-sensor-108 data-sensor-119 data-sensor-123>
3244
+ <div class="ncd-dependent" data-sensor-33 data-sensor-35 data-sensor-108 data-sensor-119 data-sensor-123 data-sensor-125 data-sensor-126>
3126
3245
  <div class="form-row ncd-active-check">
3127
3246
  <strong>Counter Threshold</strong>
3128
3247
  <p class="caption">
@@ -3140,6 +3259,9 @@
3140
3259
  <label for="node-input-counter_threshold_108"><i class="icon-tag"></i>Value:</label>
3141
3260
  <input type="text" id="node-input-counter_threshold_108" placeholder="1000" value="1000">
3142
3261
  </div>
3262
+ <p class="caption">
3263
+ Default value: Disabled (0).
3264
+ </p>
3143
3265
  </div>
3144
3266
  </div>
3145
3267
  <div class="ncd-dependent" data-sensor-108>
@@ -3197,15 +3319,15 @@
3197
3319
  </div>
3198
3320
  </div>
3199
3321
  </div>
3200
- <div class="ncd-dependent" data-sensor-123>
3322
+ <div class="ncd-dependent" data-sensor-123 data-sensor-126>
3201
3323
  <div class="form-row ncd-active-check">
3202
3324
  <strong>Enable Push Notification</strong>
3203
3325
  <p>
3204
3326
  Enables the sensor to immediately transmit data upon detecting a signal change on the specified input(s).<br>
3205
3327
  **Report type will be 'Interrupt'.<br><br>
3206
- IO1 - Digital input 1<br>
3207
- IO2 - Digital input 2<br>
3208
- IO3 - Digital input 3<br>
3328
+ IO1 - Input 1<br>
3329
+ IO2 - Input 2<br>
3330
+ IO3 - Input 3<br>
3209
3331
  </p>
3210
3332
  <div>
3211
3333
  <label for="node-input-push_notification_123_active">Active:</label>
@@ -3227,6 +3349,32 @@
3227
3349
  </div>
3228
3350
  </div>
3229
3351
  </div>
3352
+ <div class="ncd-dependent" data-sensor-125>
3353
+ <div class="form-row ncd-active-check">
3354
+ <strong>Enable Push Notification</strong>
3355
+ <p>
3356
+ Enables the sensor to immediately transmit data upon detecting a signal change on the specified input(s).<br>
3357
+ **Report type will be 'Interrupt'.<br><br>
3358
+ IO1 - Input 1<br>
3359
+ IO2 - Input 2<br>
3360
+ </p>
3361
+ <div>
3362
+ <label for="node-input-push_notification_125_active">Active:</label>
3363
+ <input type="checkbox" id="node-input-push_notification_125_active" class="ncd-config-toggle" data-target-id="node-input-push_notification_125" value="1">
3364
+ </div>
3365
+ <div>
3366
+ <label for="node-input-push_notification_125"><i class="icon-tag"></i>Value:</label>
3367
+ <select id="node-input-push_notification_125">
3368
+ <option value="0" selected>Disable All</option>
3369
+ <!-- <option value="7">Enable All</option> -->
3370
+ <!-- <option value="31">Enable All</option> -->
3371
+ <option value="1">Enable on IO1</option>
3372
+ <option value="2">Enable on IO2</option>
3373
+ <option value="3">Enable All</option>
3374
+ </select>
3375
+ </div>
3376
+ </div>
3377
+ </div>
3230
3378
  <div class="ncd-dependent" data-sensor-119>
3231
3379
  <div class="form-row ncd-active-check">
3232
3380
  <strong>Enable Push Notification</strong>
@@ -3249,7 +3397,7 @@
3249
3397
  </div>
3250
3398
  </div>
3251
3399
  </div>
3252
- <div class="ncd-dependent" data-sensor-108 data-sensor-123 data-sensor-119>
3400
+ <div class="ncd-dependent" data-sensor-33 data-sensor-35 data-sensor-108 data-sensor-123 data-sensor-125 data-sensor-126 data-sensor-119>
3253
3401
  <div class="form-row ncd-active-check">
3254
3402
  <strong>Data Transmission Interval</strong>
3255
3403
  <p class="caption">
@@ -3283,8 +3431,7 @@
3283
3431
  <strong> Set Reset Mode</strong>
3284
3432
  <p class="caption">
3285
3433
  This setting specifies which automatic reset option the sensor will utilize.<br>
3286
- Note: Works in conjunction with the "Reset Timeout" and "Set Shift Time" commands.<br><br>
3287
- Default value: Disabled
3434
+ Note: Works in conjunction with the "Reset Timeout" and "Set Shift Time" commands.
3288
3435
  </p>
3289
3436
  <div>
3290
3437
  <label for="node-input-reset_mode_to_disabled_108_active">Active:</label>
@@ -3298,6 +3445,9 @@
3298
3445
  <option value="2">Based on the Timeout Provided</option>
3299
3446
  </select>
3300
3447
  </div>
3448
+ <p class="caption">
3449
+ Default value: Disabled.
3450
+ </p>
3301
3451
  </div>
3302
3452
  <div class="form-row ncd-active-check">
3303
3453
  <strong>Reset Timeout</strong>
@@ -3424,6 +3574,8 @@
3424
3574
  <input type="checkbox" id="node-input-rtc_108" value="1">
3425
3575
  </div>
3426
3576
  </div>
3577
+ </div>
3578
+ <div class="ncd-dependent" data-sensor-35 data-sensor-108 data-sensor-123 data-sensor-119>
3427
3579
  <div class="form-row ncd-active-check">
3428
3580
  <strong>Set FLY Interval</strong>
3429
3581
  <p class="caption">
@@ -3446,13 +3598,16 @@
3446
3598
  <option value="1440">24 Hours</option>
3447
3599
  </select>
3448
3600
  </div>
3601
+ <p class="caption">
3602
+ Default value: 1 Hour.
3603
+ </p>
3449
3604
  </div>
3450
3605
  </div>
3451
3606
  <div class="ncd-dependent" data-sensor-108 data-sensor-119>
3452
3607
  <div class="form-row ncd-active-check">
3453
3608
  <strong>Set Accelerometer Sample Rate</strong>
3454
3609
  <p class="caption">
3455
- This setting defines the number of measurements the sensor takes per second, measured in Hertz (Hz).
3610
+ This setting defines the number of measurements the sensor takes per second, measured in Hertz (Hz).<br><br>
3456
3611
  **Only applies to sensor with firmware version 8 and above.
3457
3612
  </p>
3458
3613
  <div>
@@ -3536,27 +3691,6 @@
3536
3691
  </p>
3537
3692
  </div>
3538
3693
  </div>
3539
- <div class="ncd-dependent" data-sensor-35 data-sensor-36>
3540
- <hr>
3541
- <div class="form-row ncd-active-check">
3542
- <strong>Counter Threshold</strong>
3543
- <p class="caption">
3544
- The sensor will transmit data when any connected counter reaches a multiple of this threshold value.<br>
3545
- **Report type will be 'Threshold'.
3546
- <br>
3547
- <br>
3548
- Note: The range for this value is from 0 to 65534 and must be multiple of 100.
3549
- </p>
3550
- <div>
3551
- <label for="node-input-counter_threshold_35_active">Active:</label>
3552
- <input type="checkbox" id="node-input-counter_threshold_35_active" class="ncd-config-toggle" data-target-id="node-input-counter_threshold_35" value="1">
3553
- </div>
3554
- <div>
3555
- <label for="node-input-counter_threshold_35"><i class="icon-tag"></i>Value:</label>
3556
- <input type="text" id="node-input-counter_threshold_35" placeholder="50" value="50">
3557
- </div>
3558
- </div>
3559
- </div>
3560
3694
  <div class="ncd-dependent" data-sensor-110 data-sensor-111 data-sensor-112 data-sensor-114 data-sensor-543>
3561
3695
  <div class="form-row ncd-active-check">
3562
3696
  <strong>Set Filtering</strong>
@@ -4499,23 +4633,7 @@
4499
4633
  <div id="config_response"></div>
4500
4634
  </div>
4501
4635
  </div>
4502
- <div class="ncd-dependent" data-sensor-2 data-sensor-35 data-sensor-36>
4503
- <div class="form-row ncd-active-check">
4504
- <strong>Set Input Debounce Time</strong>
4505
- <p class="caption">
4506
- Sets the debounce time in milliseconds on inputs. State changes to the input during this debounce time will be ignored. Generally recommended for mechanically triggered state changes such as button or relay/contactor outputs.
4507
- </p>
4508
- <div>
4509
- <label for="node-input-debounce_time_2_active">Active:</label>
4510
- <input type="checkbox" id="node-input-debounce_time_2_active" class="ncd-config-toggle" data-target-id="node-input-debounce_time_2" value="1">
4511
- </div>
4512
- <div>
4513
- <label for="node-input-debounce_time_2"><i class="icon-tag"></i>Value:</label>
4514
- <input type="text" id="node-input-debounce_time_2" placeholder="10" value="10">
4515
- </div>
4516
- </div>
4517
- </div>
4518
- <div class="ncd-dependent" data-sensor-87 data-sensor-120 data-sensor-539 data-sensor-1010 data-sensor-1011>
4636
+ <!-- <div class="ncd-dependent" data-sensor-87 data-sensor-120 data-sensor-539 data-sensor-1010 data-sensor-1011>
4519
4637
  <div class="form-row ncd-active-check">
4520
4638
  <strong>Set Stay On Mode</strong>
4521
4639
  <div>
@@ -4530,7 +4648,7 @@
4530
4648
  </select>
4531
4649
  </div>
4532
4650
  </div>
4533
- </div>
4651
+ </div> -->
4534
4652
  <div class="ncd-dependent" data-sensor-539 data-sensor-1010 data-sensor-1011>
4535
4653
  <div class="form-row ncd-active-check">
4536
4654
  <strong>Set Baud Rate</strong>
@@ -5585,7 +5703,7 @@
5585
5703
  <div class="ncd-dependent" data-sensor-103>
5586
5704
  <div class="form-row ncd-active-check">
5587
5705
  <strong>Set Sampling Duration</strong>
5588
- <p>Set the sampling duration in miliseconds<br>
5706
+ <p>Set the sampling duration in milliseconds<br>
5589
5707
  Example: a value of 1 = 50msec, 2 = 100msec, 100 = 5000msec</p>
5590
5708
  <div>
5591
5709
  <label for="node-input-sampling_duration_103_active">Active:</label>
@@ -5596,7 +5714,7 @@
5596
5714
  <input type="text" id="node-input-sampling_duration_103">
5597
5715
  </div>
5598
5716
  <p class="caption">
5599
- Default value: 20 miliseconds.
5717
+ Default value: 20 milliseconds.
5600
5718
  </p>
5601
5719
  </div>
5602
5720
  <div class="form-row ncd-active-check">
@@ -5618,6 +5736,8 @@
5618
5736
  </div>
5619
5737
  <div class="form-row ncd-active-check">
5620
5738
  <strong>Set Accelerometer ODR</strong>
5739
+ <p class="caption">
5740
+ </p>
5621
5741
  <div>
5622
5742
  <label for="node-input-acc_output_data_rate_103_active"><i class="icon-tag"></i>Active:</label>
5623
5743
  <input type="checkbox" id="node-input-acc_output_data_rate_103_active" class="ncd-config-toggle" data-target-id="node-input-acc_output_data_rate_103" value="1">
@@ -5627,9 +5747,9 @@
5627
5747
  <select id="node-input-acc_output_data_rate_103">
5628
5748
  <option value="0">8000Hz</option>
5629
5749
  <option value="1">4000Hz</option>
5630
- <option value="2">2000Hz</option>
5631
- <option value="3">1000Hz</option>
5632
- <option value="4">100Hz</option>
5750
+ <option value="2">1000Hz</option>
5751
+ <option value="3">100Hz</option>
5752
+ <option value="4">250Hz</option>
5633
5753
  </select>
5634
5754
  </div>
5635
5755
  <p class="caption">
@@ -5754,6 +5874,23 @@
5754
5874
  <i>Note: Setting this to a higher value will drain the battery.</i>
5755
5875
  </p>
5756
5876
  </div>
5877
+ <div class="form-row ncd-active-check">
5878
+ <strong>Set Raw On Motion Only</strong>
5879
+ <div>
5880
+ <label for="node-input-send_raw_on_motion_only_103_active"><i class="icon-tag"></i>Active:</label>
5881
+ <input type="checkbox" id="node-input-send_raw_on_motion_only_103_active" class="ncd-config-toggle" data-target-id="node-input-send_raw_on_motion_only_103" value="1">
5882
+ </div>
5883
+ <div>
5884
+ <label for="node-input-send_raw_on_motion_only_103"><i class="icon-tag"></i>Value:</label>
5885
+ <select id="node-input-send_raw_on_motion_only_103">
5886
+ <option value="1">Enabled</option>
5887
+ <option value="0">disabled</option>
5888
+ </select>
5889
+ </div>
5890
+ <p class="caption">
5891
+ Default value: Disabled.
5892
+ </p>
5893
+ </div>
5757
5894
  </div>
5758
5895
  <div class="ncd-dependent" data-sensor-270>
5759
5896
  <!-- <div class="form-row ncd-active-check">
@@ -6900,6 +7037,211 @@
6900
7037
  </div>
6901
7038
  </div>
6902
7039
  </div>
7040
+ <div class="ncd-dependent" data-sensor-33 data-sensor-35>
7041
+ <div class="form-row ncd-active-check">
7042
+ <strong>Clear Counter</strong>
7043
+ <p class="caption">
7044
+ Resets the Input counter and the corresponding uptime value to zero in the next sensor configuration.
7045
+ </p>
7046
+ <div>
7047
+ <label for="node-input-clear_timers_35">Active:</label>
7048
+ <input type="checkbox" id="node-input-clear_timers_35" value="1">
7049
+ </div>
7050
+ <p class="caption">
7051
+ Default value: Disabled.
7052
+ </p>
7053
+ </div>
7054
+ </div>
7055
+ <div class="ncd-dependent" data-sensor-33 data-sensor-35>
7056
+ <div class="form-row ncd-active-check">
7057
+ <strong>Enable Push Notification</strong>
7058
+ <p>
7059
+ Enables the sensor to immediately transmit data upon detecting a signal change on the input.
7060
+ **Report type will be 'Interrupt'.<br><br>
7061
+ </p>
7062
+ <div>
7063
+ <label for="node-input-push_notification_35_active">Active:</label>
7064
+ <input type="checkbox" id="node-input-push_notification_35_active" class="ncd-config-toggle" data-target-id="node-input-push_notification_35" value="1">
7065
+ </div>
7066
+ <div>
7067
+ <label for="node-input-push_notification_35"><i class="icon-tag"></i>Value:</label>
7068
+ <select id="node-input-push_notification_35">
7069
+ <option value="0" selected>Disabled</option>
7070
+ <option value="1">Enabled</option>
7071
+ </select>
7072
+ </div>
7073
+ <p class="caption">
7074
+ Default value: Disabled.
7075
+ </p>
7076
+ </div>
7077
+ </div>
7078
+ <div class="ncd-dependent" data-sensor-33 data-sensor-35 data-sensor-125 data-sensor-126>
7079
+ <div class="form-row ncd-active-check">
7080
+ <strong>Set Interrupt Timeout</strong>
7081
+ <p class="caption">
7082
+ Set the sensor to detect an initial IO (input/output) change and not transmit subsequent IO changes for a specified duration; set the duration value to control how long changes are ignored in milliseconds, set it to 0 to disable ignoring.<br><br>
7083
+ Valid range: 0 - 65000 milliseconds.
7084
+ </p>
7085
+ <div>
7086
+ <label for="node-input-interrupt_timeout_35_active">Active:</label>
7087
+ <input type="checkbox" id="node-input-interrupt_timeout_35_active" class="ncd-config-toggle" data-target-id="node-input-interrupt_timeout_35" value="1">
7088
+ </div>
7089
+ <div>
7090
+ <label for="node-input-interrupt_timeout_35"><i class="icon-tag"></i>Value:</label>
7091
+ <input type="text" id="node-input-interrupt_timeout_35" placeholder="0" value="0">
7092
+ </div>
7093
+ <p class="caption">
7094
+ Default value: 0 milliseconds (Disabled)
7095
+ </p>
7096
+ </div>
7097
+ </div>
7098
+ <!-- <div class="ncd-dependent" data-sensor-33 data-sensor-35>
7099
+ <div class="form-row ncd-active-check">
7100
+ <strong>Counter Threshold</strong>
7101
+ <p class="caption">
7102
+ The sensor will transmit data when any counter reaches a multiple of this threshold value.<br>
7103
+ **Report type will be 'Threshold'.<br><br>
7104
+ Note: The range for this value is from 0 to 65534 and must be multiple of 100.
7105
+ </p>
7106
+ <div>
7107
+ <label for="node-input-counter_threshold_35_gen2_active">Active:</label>
7108
+ <input type="checkbox" id="node-input-counter_threshold_35_gen2_active" class="ncd-config-toggle" data-target-id="node-input-counter_threshold_35_gen2" value="1">
7109
+ </div>
7110
+ <div>
7111
+ <label for="node-input-counter_threshold_35_gen2"><i class="icon-tag"></i>Value:</label>
7112
+ <input type="text" id="node-input-counter_threshold_35_gen2" placeholder="1000" value="1000">
7113
+ </div>
7114
+ <p class="caption">
7115
+ Default value: Disabled (0).
7116
+ </p>
7117
+ </div>
7118
+ </div> -->
7119
+ <div class="ncd-dependent" data-sensor-33 data-sensor-125 data-sensor-126>
7120
+ <div class="form-row ncd-active-check">
7121
+ <strong>Set Sensor One CT</strong>
7122
+ <p>
7123
+ Select the AC Current probe type for Input 1.
7124
+ </p>
7125
+ <div>
7126
+ <label for="node-input-probe_one_126_active">Active:</label>
7127
+ <input type="checkbox" id="node-input-probe_one_126_active" class="ncd-config-toggle" data-target-id="node-input-probe_one_126" value="1">
7128
+ </div>
7129
+ <div>
7130
+ <label for="node-input-probe_one_126"><i class="icon-tag"></i>Value:</label>
7131
+ <select id="node-input-probe_one_126">
7132
+ <option value="0" selected>100A</option>
7133
+ <option value="1">200A</option>
7134
+ <option value="2">600A</option>
7135
+ <option value="3">1000A</option>
7136
+ </select>
7137
+ </div>
7138
+ <p class="caption">
7139
+ Default value: 100A.
7140
+ </p>
7141
+ </div>
7142
+ <div class="form-row ncd-active-check">
7143
+ <strong>Set AC Current Threshold One</strong>
7144
+ <p class="caption">
7145
+ The sensor increments the cycle counter and calculates uptime once the measured AC Current exceeds this threshold.<br>
7146
+ Note: This range depends on the selected AC Current probe type.
7147
+ </p>
7148
+ <div>
7149
+ <label for="node-input-threshold_probe_one_126_active">Active:</label>
7150
+ <input type="checkbox" id="node-input-threshold_probe_one_126_active" class="ncd-config-toggle" data-target-id="node-input-threshold_probe_one_126" value="1">
7151
+ </div>
7152
+ <div>
7153
+ <label for="node-input-threshold_probe_one_126"><i class="icon-tag"></i>Value:</label>
7154
+ <input type="text" id="node-input-threshold_probe_one_126" placeholder="1" value="1">
7155
+ </div>
7156
+ <p class="caption">
7157
+ Default value: 3A.
7158
+ </p>
7159
+ </div>
7160
+ </div>
7161
+ <div class="ncd-dependent" data-sensor-125 data-sensor-126>
7162
+ <div class="form-row ncd-active-check">
7163
+ <strong>Set Sensor Two CT</strong>
7164
+ <p>
7165
+ Select the AC Current probe type for Input 2.
7166
+ </p>
7167
+ <div>
7168
+ <label for="node-input-probe_two_126_active">Active:</label>
7169
+ <input type="checkbox" id="node-input-probe_two_126_active" class="ncd-config-toggle" data-target-id="node-input-probe_two_126" value="1">
7170
+ </div>
7171
+ <div>
7172
+ <label for="node-input-probe_two_126"><i class="icon-tag"></i>Value:</label>
7173
+ <select id="node-input-probe_two_126">
7174
+ <option value="0" selected>100A</option>
7175
+ <option value="1">200A</option>
7176
+ <option value="2">600A</option>
7177
+ <option value="3">1000A</option>
7178
+ </select>
7179
+ </div>
7180
+ <p class="caption">
7181
+ Default value: 100A.
7182
+ </p>
7183
+ </div>
7184
+ <div class="form-row ncd-active-check">
7185
+ <strong>Set AC Current Threshold Two</strong>
7186
+ <p class="caption">
7187
+ The sensor increments the cycle counter and calculates uptime once the measured AC Current exceeds this threshold.<br>
7188
+ Note: This range depends on the selected AC Current probe type.
7189
+ </p>
7190
+ <div>
7191
+ <label for="node-input-threshold_probe_two_126_active">Active:</label>
7192
+ <input type="checkbox" id="node-input-threshold_probe_two_126_active" class="ncd-config-toggle" data-target-id="node-input-threshold_probe_two_126" value="1">
7193
+ </div>
7194
+ <div>
7195
+ <label for="node-input-threshold_probe_two_126"><i class="icon-tag"></i>Value:</label>
7196
+ <input type="text" id="node-input-threshold_probe_two_126" placeholder="1" value="1">
7197
+ </div>
7198
+ <p class="caption">
7199
+ Default value: 3A.
7200
+ </p>
7201
+ </div>
7202
+ </div>
7203
+ <div class="ncd-dependent" data-sensor-126>
7204
+ <div class="form-row ncd-active-check">
7205
+ <strong>Set Sensor Three CT</strong>
7206
+ <p>
7207
+ Select the AC Current probe type for Input 3.
7208
+ </p>
7209
+ <div>
7210
+ <label for="node-input-probe_three_126_active">Active:</label>
7211
+ <input type="checkbox" id="node-input-probe_three_126_active" class="ncd-config-toggle" data-target-id="node-input-probe_three_126" value="1">
7212
+ </div>
7213
+ <div>
7214
+ <label for="node-input-probe_three_126"><i class="icon-tag"></i>Value:</label>
7215
+ <select id="node-input-probe_three_126">
7216
+ <option value="0" selected>100A</option>
7217
+ <option value="1">200A</option>
7218
+ <option value="2">600A</option>
7219
+ <option value="3">1000A</option>
7220
+ </select>
7221
+ </div>
7222
+ <p class="caption">
7223
+ Default value: 100A.
7224
+ </p>
7225
+ </div>
7226
+ <div class="form-row ncd-active-check">
7227
+ <strong>Set AC Current Threshold Three</strong>
7228
+ <p class="caption">
7229
+ The sensor increments the cycle counter and calculates uptime once the measured AC Current exceeds this threshold.<br>
7230
+ Note: This range depends on the selected AC Current probe type.
7231
+ </p>
7232
+ <div>
7233
+ <label for="node-input-threshold_probe_three_126_active">Active:</label>
7234
+ <input type="checkbox" id="node-input-threshold_probe_three_126_active" class="ncd-config-toggle" data-target-id="node-input-threshold_probe_three_126" value="1">
7235
+ </div>
7236
+ <div>
7237
+ <label for="node-input-threshold_probe_three_126"><i class="icon-tag"></i>Value:</label>
7238
+ <input type="text" id="node-input-threshold_probe_three_126" placeholder="1" value="1">
7239
+ </div>
7240
+ <p class="caption">
7241
+ Default value: 3A.
7242
+ </p>
7243
+ </div>
7244
+ </div>
6903
7245
  </div>
6904
7246
  </div>
6905
7247
  </script>
@@ -6974,7 +7316,8 @@
6974
7316
  port: {value: ""},
6975
7317
  baudRate: {value: 115200, validate:RED.validators.number()},
6976
7318
  pan_id: {value: '7FFF', validate: NCD_validators.number_range(0, 0x7FFF, 16)},
6977
- rssi: {value: ""}
7319
+ rssi: {value: ""},
7320
+ enable_fly_compatibility: {value: ""}
6978
7321
  },
6979
7322
  label: function(){
6980
7323
  if(this.name) return this.name;
@@ -7115,4 +7458,10 @@
7115
7458
  <label for="node-config-input-rssi"><i class="icon-tag"></i> Add RSSI to incoming packets</label>
7116
7459
  <input type="checkbox" id="node-config-input-rssi" value="1">
7117
7460
  </div>
7461
+ <div class="form-row">
7462
+ <label for="node-config-input-enable_fly_compatibility"><i class="icon-tag"></i> Enable Fly Compatibility</label>
7463
+ <input type="checkbox" id="node-config-input-enable_fly_compatibility" value="1">
7464
+ <p>When active, this settings allows sensors that send the Sync messages to also send the older FLY messages.</p>
7465
+ <p>It is only recommended to enable this setting if you have existing flows that rely on the older FLY message format such as for dynamic configuration. It is recommended to utilize the new API Configuration Node instead.</p>
7466
+ </div>
7118
7467
  </script>