@nanobpm/nano-workforce 0.174.1 → 0.175.0

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
package/CHANGELOG.md CHANGED
@@ -1,3 +1,9 @@
1
+ ## [0.175.0](https://github.com/nanobpm/nano-workforce/compare/v0.174.1...v0.175.0) (2026-09-02)
2
+
3
+ ### Features
4
+
5
+ * **agentic:** engine/poller-owned relay transcript completion (retire the presence heuristic) ([#708](https://github.com/nanobpm/nano-workforce/issues/708)) ([74f42f6](https://github.com/nanobpm/nano-workforce/commit/74f42f6fa3f1b07a6608ccf50979693eecb8ead4)), closes [689/#690](https://github.com/689/nano-workforce/issues/690) [#661](https://github.com/nanobpm/nano-workforce/issues/661) [#691](https://github.com/nanobpm/nano-workforce/issues/691) [#691](https://github.com/nanobpm/nano-workforce/issues/691) [#691](https://github.com/nanobpm/nano-workforce/issues/691) [#unlink](https://github.com/nanobpm/nano-workforce/issues/unlink)
6
+
1
7
  ## [0.174.1](https://github.com/nanobpm/nano-workforce/compare/v0.174.0...v0.174.1) (2026-09-02)
2
8
 
3
9
  ### Bug Fixes
@@ -956,6 +956,198 @@ test("#689 mid-job reconnect: with no isInstanceLive wired, a producer disconnec
956
956
  service.teardown();
957
957
  });
958
958
 
959
+ test("#691 engine-owned disconnect: a mid-job reconnect whose engine job is still parked keeps the correlation live", async () => {
960
+ const registry = new ConnectionRegistry();
961
+ const correlation = new CorrelationRegistry();
962
+ const byConnection = new Map([["conn-old", "worker-E"]]);
963
+ // The engine is the completion authority (#691): while the harness holds the lease the job stays
964
+ // parked (resolver returns an element-instance key), so a producer disconnect must NOT complete it.
965
+ let parked = true;
966
+ const resolveElementInstance = (jobKey: string) =>
967
+ Promise.resolve(parked && jobKey === "9001" ? "ei-9001" : undefined);
968
+ // isInstanceLive is deliberately NOT wired (static () => false): the engine job-state — not the
969
+ // presence heuristic — must be what spares the reconnect, proving presence is no longer the authority.
970
+ const { service, hub } = mkCorrelatedService(registry, memoryDb(), correlation, byConnection, {
971
+ resolveElementInstance,
972
+ });
973
+ const p = connect("conn-old", registry);
974
+ hub.handler?.(produce(jobStream("9001"), 1, "booting agent"), p.conn);
975
+ assertEquals(correlation.jobKeysFor("worker-E"), ["9001"], "the job links on first produce");
976
+
977
+ // The producer WS blips: the old connection drops (no new one yet — presence would report the
978
+ // instance NOT live). A frame drives #reconcile → drops the dead producer + kicks the engine reconcile.
979
+ registry.remove("conn-old");
980
+ const other = connect("cons", registry);
981
+ hub.handler?.(grant(0), other.conn);
982
+ await tick(); // let the fire-and-forget engine reconcile settle
983
+ assertEquals(correlation.jobKeysFor("worker-E"), ["9001"], "a still-parked job survives the disconnect");
984
+ assertEquals(service.transcriptOf(jobStream("9001")), undefined, "the still-active stream is NOT archived");
985
+ assertEquals(service.liveFallback(jobStream("9001"))?.ring !== undefined, true, "the transcript is still live");
986
+
987
+ // The worker resumes producing on a NEW connection over the same job → re-attributed, still one job.
988
+ byConnection.set("conn-new", "worker-E");
989
+ const p2 = connect("conn-new", registry);
990
+ hub.handler?.(produce(jobStream("9001"), 1, "resumed output"), p2.conn);
991
+ assertEquals(correlation.jobKeysFor("worker-E"), ["9001"], "the resumed producer stays linked to the same job");
992
+
993
+ // The job genuinely ends: the engine park vanishes. The periodic backstop pass completes + archives it.
994
+ parked = false;
995
+ await service.reconcileEngineCorrelations();
996
+ assertEquals(correlation.jobKeysFor("worker-E"), [], "the ended job is released");
997
+ assertEquals(service.transcriptOf(jobStream("9001"))?.status, "completed", "and its transcript is archived");
998
+ service.teardown();
999
+ });
1000
+
1001
+ test("#691 engine-owned disconnect: a true exit whose engine job is gone completes + archives the stream", async () => {
1002
+ const registry = new ConnectionRegistry();
1003
+ const correlation = new CorrelationRegistry();
1004
+ const byConnection = new Map([["prod", "worker-X"]]);
1005
+ // The engine reports the job GONE at disconnect time (a clean completion whose terminal lifecycle
1006
+ // event was missed, or an unclean exit): the disconnect-driven engine reconcile completes it.
1007
+ const resolveElementInstance = () => Promise.resolve(undefined);
1008
+ const { service, hub } = mkCorrelatedService(registry, memoryDb(), correlation, byConnection, {
1009
+ resolveElementInstance,
1010
+ });
1011
+ const p = connect("prod", registry);
1012
+ hub.handler?.(produce(jobStream("kX"), 1, "x"), p.conn);
1013
+ assertEquals(correlation.jobKeysFor("worker-X"), ["kX"]);
1014
+
1015
+ registry.remove("prod");
1016
+ const other = connect("cons", registry);
1017
+ hub.handler?.(grant(0), other.conn);
1018
+ await tick(); // the fire-and-forget engine reconcile resolves "gone" → completes
1019
+ assertEquals(correlation.jobKeysFor("worker-X"), [], "a truly-ended job is released on disconnect");
1020
+ assertEquals(service.transcriptOf(jobStream("kX"))?.status, "completed", "and its transcript is archived");
1021
+ service.teardown();
1022
+ });
1023
+
1024
+ test("#691 engine-owned disconnect: an UNLINKED job stream (register/produce race) whose engine job is still parked is NOT archived on disconnect", async () => {
1025
+ const registry = new ConnectionRegistry();
1026
+ const correlation = new CorrelationRegistry();
1027
+ // The connection→instance map is deliberately EMPTY at first produce: the producer's presence
1028
+ // instance is not yet resolvable (the documented register/produce race), so #link leaves the job
1029
+ // stream UNLINKED (`state.linked` stays false) even though it IS a job stream and a resolver is
1030
+ // wired. The engine — not `state.linked` — must own the disconnect completion decision, otherwise
1031
+ // a mid-job reconnect that raced the link would wrongly fall through to the presence fallback and
1032
+ // archive a still-parked job.
1033
+ const byConnection = new Map<string, string>();
1034
+ let parked = true;
1035
+ const resolveElementInstance = (jobKey: string) =>
1036
+ Promise.resolve(parked && jobKey === "7742" ? "ei-7742" : undefined);
1037
+ const { service, hub } = mkCorrelatedService(registry, memoryDb(), correlation, byConnection, {
1038
+ resolveElementInstance,
1039
+ });
1040
+ const p = connect("conn-old", registry);
1041
+ hub.handler?.(produce(jobStream("7742"), 1, "booting agent"), p.conn);
1042
+ assertEquals(correlation.count(), 0, "the stream did NOT link — the instance was not resolvable at produce time");
1043
+
1044
+ // The old producer connection blips before a later produce could retry the link. A frame drives
1045
+ // #reconcile → it must defer to the engine (job still parked) rather than archive on presence.
1046
+ registry.remove("conn-old");
1047
+ const other = connect("cons", registry);
1048
+ hub.handler?.(grant(0), other.conn);
1049
+ await tick(); // let the fire-and-forget engine reconcile settle
1050
+ assertEquals(
1051
+ service.transcriptOf(jobStream("7742")),
1052
+ undefined,
1053
+ "an unlinked-but-still-parked job is NOT archived on disconnect",
1054
+ );
1055
+ assertEquals(service.liveFallback(jobStream("7742"))?.ring !== undefined, true, "its transcript is still live");
1056
+
1057
+ // The worker resumes on a NEW connection; the instance now resolves → the late link finally lands.
1058
+ byConnection.set("conn-new", "worker-R");
1059
+ const p2 = connect("conn-new", registry);
1060
+ hub.handler?.(produce(jobStream("7742"), 1, "resumed output"), p2.conn);
1061
+ assertEquals(correlation.jobKeysFor("worker-R"), ["7742"], "the late link succeeds on reconnect once the instance resolves");
1062
+
1063
+ // The job genuinely ends: the engine park vanishes → the backstop pass completes + archives it.
1064
+ parked = false;
1065
+ await service.reconcileEngineCorrelations();
1066
+ assertEquals(correlation.jobKeysFor("worker-R"), [], "the ended job is released");
1067
+ assertEquals(service.transcriptOf(jobStream("7742"))?.status, "completed", "and its transcript is archived");
1068
+ service.teardown();
1069
+ });
1070
+
1071
+ test("#708 periodic backstop covers an UNLINKED job stream: an unlinked-but-parked disconnect that never reconnects is completed once the engine park ends", async () => {
1072
+ const registry = new ConnectionRegistry();
1073
+ const correlation = new CorrelationRegistry();
1074
+ // Same register/produce race as #691: the connection→instance map is empty, so #link leaves the
1075
+ // job stream UNLINKED. The producer then drops while the engine job is still parked, so the
1076
+ // disconnect path keeps the stream live and clears `state.producer` (so #reconcile does not
1077
+ // re-trigger). Critically the worker NEVER reconnects — no later `produce` ever links it. The
1078
+ // periodic backstop is now the ONLY actor that can retire it, so it must include unlinked job
1079
+ // streams in its reconcile snapshot; otherwise the stream leaks live forever once the engine job
1080
+ // becomes terminal.
1081
+ const byConnection = new Map<string, string>();
1082
+ let parked = true;
1083
+ const resolveElementInstance = (jobKey: string) =>
1084
+ Promise.resolve(parked && jobKey === "7708" ? "ei-7708" : undefined);
1085
+ const { service, hub } = mkCorrelatedService(registry, memoryDb(), correlation, byConnection, {
1086
+ resolveElementInstance,
1087
+ });
1088
+ const p = connect("conn-old", registry);
1089
+ hub.handler?.(produce(jobStream("7708"), 1, "booting agent"), p.conn);
1090
+ assertEquals(correlation.count(), 0, "the stream did NOT link — the instance was not resolvable at produce time");
1091
+
1092
+ // Producer blips; the disconnect engine-reconcile keeps the still-parked stream live and clears
1093
+ // the producer so #reconcile will not revisit it on later frames.
1094
+ registry.remove("conn-old");
1095
+ const other = connect("cons", registry);
1096
+ hub.handler?.(grant(0), other.conn);
1097
+ await tick();
1098
+ assertEquals(
1099
+ service.transcriptOf(jobStream("7708")),
1100
+ undefined,
1101
+ "an unlinked-but-still-parked job is NOT archived on disconnect",
1102
+ );
1103
+
1104
+ // The engine job genuinely ends. With NO reconnect to link it, only the periodic backstop can
1105
+ // retire it — and it must, even though the stream is unlinked.
1106
+ parked = false;
1107
+ await service.reconcileEngineCorrelations();
1108
+ assertEquals(
1109
+ service.transcriptOf(jobStream("7708"))?.status,
1110
+ "completed",
1111
+ "the periodic backstop completes an unlinked job stream once the engine park disappears",
1112
+ );
1113
+ assertEquals(service.liveFallback(jobStream("7708")), undefined, "and its live ring is retired");
1114
+ service.teardown();
1115
+ });
1116
+
1117
+ test("#691 engine-owned disconnect: a transient engine read at disconnect never falsely completes; the backstop retries", async () => {
1118
+ const registry = new ConnectionRegistry();
1119
+ const correlation = new CorrelationRegistry();
1120
+ const byConnection = new Map([["prod", "worker-T"]]);
1121
+ // The disconnect-time engine read throws (unavailable). A transient fault must be treated as
1122
+ // "unknown — keep it linked", NEVER as "job gone": the stream stays live until a later pass resolves.
1123
+ let failing = true;
1124
+ let gone = false;
1125
+ const resolveElementInstance = () => {
1126
+ if (failing) return Promise.reject(new Error("engine unavailable"));
1127
+ return Promise.resolve(gone ? undefined : "ei-T");
1128
+ };
1129
+ const { service, hub } = mkCorrelatedService(registry, memoryDb(), correlation, byConnection, {
1130
+ resolveElementInstance,
1131
+ });
1132
+ const p = connect("prod", registry);
1133
+ hub.handler?.(produce(jobStream("kT"), 1, "x"), p.conn);
1134
+
1135
+ registry.remove("prod");
1136
+ const other = connect("cons", registry);
1137
+ hub.handler?.(grant(0), other.conn);
1138
+ await tick(); // the engine read rejects → the stream must stay linked, not complete
1139
+ assertEquals(correlation.jobKeysFor("worker-T"), ["kT"], "a transient engine failure leaves the job linked");
1140
+ assertEquals(service.transcriptOf(jobStream("kT")), undefined, "and its transcript is NOT archived");
1141
+
1142
+ // The engine recovers and now reports the job gone: the periodic backstop pass completes it.
1143
+ failing = false;
1144
+ gone = true;
1145
+ await service.reconcileEngineCorrelations();
1146
+ assertEquals(correlation.jobKeysFor("worker-T"), [], "the backstop pass releases the ended job");
1147
+ assertEquals(service.transcriptOf(jobStream("kT"))?.status, "completed", "and archives its transcript");
1148
+ service.teardown();
1149
+ });
1150
+
959
1151
  test("H6 correlation write-side: non-job streams are never linked; a link retries until the instance resolves", () => {
960
1152
  const registry = new ConnectionRegistry();
961
1153
  const correlation = new CorrelationRegistry();
@@ -254,15 +254,18 @@ export interface RelayTranscriptServiceOptions {
254
254
  readonly instanceForConnection?: (connectionId: string) => string | undefined;
255
255
  /**
256
256
  * Whether a worker instance is still live on any hub connection (#689). Wired to the presence
257
- * registry's {@link PresenceRegistry.isInstanceLive}. The disconnect-driven reconcile uses it to
258
- * spare a still-active job's stream when its worker merely RECONNECTED mid-job (old producer
259
- * connection dropped, a new one re-registered under the same instance): completing then would
260
- * archive a live job's transcript and release its correlation, wedging the cockpit (the reconnected
261
- * worker's produce frames hit a terminal `completed` stream and are ignored) while the harness
262
- * keeps the engine lease. When wired to presence, a true worker-exit still completes: presence
263
- * has dropped the instance, so this returns false. Omitted (`() => false`, the static default) →
264
- * the prior always-complete-on-disconnect behaviour every disconnect completes, reconnect
265
- * included (the seam never consults presence, so its value does not vary).
257
+ * registry's {@link PresenceRegistry.isInstanceLive}. Since #691 the disconnect-driven reconcile
258
+ * defers to the engine job-state (the poller-owned completion authority) whenever an engine view
259
+ * ({@link resolveElementInstance}) is wired, so this presence signal is consulted ONLY as the
260
+ * engine-less fallback: on a host with no engine read-model (or a non-job stream no jobKey, so
261
+ * nothing for the engine to reconcile against; an unlinked *job* stream still has a jobKey and DOES
262
+ * reconcile against the engine since #691) it spares a still-active job's stream when its worker merely
263
+ * RECONNECTED mid-job (old producer connection dropped, a new one re-registered under the same
264
+ * instance) completing then would archive a live job's transcript and release its correlation,
265
+ * wedging the cockpit (the reconnected worker's produce frames hit a terminal `completed` stream and
266
+ * are ignored). A true worker-exit still completes (presence has dropped the instance → false).
267
+ * Omitted (`() => false`, the static default) → the prior always-complete-on-disconnect behaviour in
268
+ * that fallback path.
266
269
  */
267
270
  readonly isInstanceLive?: (instance: string) => boolean;
268
271
  /**
@@ -725,27 +728,56 @@ export class RelayTranscriptService {
725
728
  }
726
729
 
727
730
  /**
728
- * Flush + complete every ephemeral stream whose producer connection is no longer live (the S1
729
- * registry dropped it on close or liveness timeout), and release its job correlation (H6, #149).
730
- * Lazy, like the relay hub's own dead-subscriber prune: it runs on each inbound frame, and shutdown
731
- * covers the quiescent tail via {@link teardown}. The correlation release is store-independent (it
732
- * runs even for an unpersisted relay), so a dropped worker's `jobKeys` always clear.
731
+ * Reconcile every ephemeral stream whose producer connection is no longer live (the S1 registry
732
+ * dropped it on close or liveness timeout). For a job stream with an engine view wired this
733
+ * defers the completion decision to the engine job-state (#691) the poller-owned authority
734
+ * regardless of whether the stream is linked yet (an unlinked job stream can still be mid-reconnect
735
+ * on the register/produce race), so a mid-job reconnect never archives a still-active job; for an
736
+ * engine-less host (or a non-job stream with no engine job to reconcile against) it flushes +
737
+ * completes the ephemeral stream and releases its correlation (H6, #149), with
738
+ * presence liveness (#689/#690) sparing a still-live instance as the only fallback signal. Lazy, like
739
+ * the relay hub's own dead-subscriber prune: it runs on each inbound frame, and shutdown covers the
740
+ * quiescent tail via {@link teardown}. The correlation release is store-independent (it runs even for
741
+ * an unpersisted relay), so a dropped worker's `jobKeys` always clear.
733
742
  */
734
743
  #reconcile(): void {
735
744
  for (const [stream, state] of this.#streams) {
736
745
  if (state.producer !== undefined && !this.#registry.has(state.producer)) {
737
- // Producer connection gone. Normally that means the job it was relaying ended — release the
738
- // correlation and flush+complete its ephemeral transcript. BUT a worker that merely
739
- // RECONNECTED mid-job (#689) also loses its old producer connection while its job keeps
740
- // running (the harness holds the engine lease and extends it). Presence re-registers the SAME
741
- // instance under the new connection, so the instance stays live even though this specific
742
- // producer connection is gone. Completing then would archive a still-active job's transcript
743
- // to `historical` and drop its correlation and because a completed stream is terminal
744
- // (`#observe` ignores later frames), the reconnected worker could NEVER re-correlate: the
745
- // cockpit shows the worker idle with a frozen transcript while the job is genuinely running.
746
- // So spare the stream while its instance is still live; the next `produce` re-attributes the
747
- // live connection (via `#observe`), a NEW job supersedes it (via `#link`), or — once the
748
- // worker truly exits presence drops the instance and a later reconcile completes it.
746
+ // Producer connection gone. Normally that means the job it was relaying ended — but a worker
747
+ // that merely RECONNECTED mid-job (#689) also loses its old producer connection while its job
748
+ // keeps running (the harness holds the engine lease and extends it). Inferring job-end from the
749
+ // relay-connection layer (the old presence heuristic, #690) conflates two independent liveness
750
+ // signals (engine lease vs. WS connection); the authoritative one is the engine job-state the
751
+ // poller already reconciles (#691).
752
+ if (this.#resolveElementInstance !== undefined && jobKeyOfStream(stream) !== undefined) {
753
+ // Engine/poller-owned completion (#691): drop the dead producer so `#reconcile` does not
754
+ // re-trigger on every subsequent frame, then reconcile THIS stream against the engine's view
755
+ // of its job (fire-and-forget the sync frame handler must not await an engine read). A
756
+ // reconnected worker's job is still parked kept live (the reconnect's next `produce`
757
+ // re-attributes the live connection via `#observe`); a genuine exit's job is gone
758
+ // completed + archived. The periodic {@link reconcileEngineCorrelations} pass is the backstop
759
+ // if this read faults transiently. Presence liveness is no longer consulted here — the
760
+ // engine job-state is the sole completion authority whenever an engine view is wired.
761
+ //
762
+ // NB: this deliberately does NOT require `state.linked`. A job stream can still be UNLINKED
763
+ // during the documented register/produce race (the producer's presence instance was not yet
764
+ // resolvable at `produce` time, so `#link` deferred). Gating the engine path on `linked`
765
+ // would fall an unlinked-but-engine-wired job through to the presence fallback below and
766
+ // archive a still-parked job mid-reconnect — the very heuristic #691 removes. The engine is
767
+ // resolvable by jobKey alone (as at link time), so defer to it regardless of `linked`;
768
+ // `#unlink` inside `completeStream` stays a no-op for a stream that never linked.
769
+ state.producer = undefined;
770
+ void this.#reconcileStreamAgainstEngine(stream).catch((err: unknown) => {
771
+ this.#log.warn("agentic relay disconnect engine-reconcile failed", { stream, err: String(err) });
772
+ });
773
+ continue;
774
+ }
775
+ // Engine-less fallback (no engine view wired — e.g. an engine-less host, or a non-job stream
776
+ // with no engine job to reconcile against): presence-liveness spares a still-live
777
+ // instance's stream (#689/#690) and a truly-gone instance completes. Presence remains a
778
+ // completion signal ONLY in this degraded path where there is no engine job-state to consult —
779
+ // never the sole authority on the engine-wired path above. (A job stream with an engine view
780
+ // wired always took the engine path above, linked or not — it never reaches here.)
749
781
  if (state.instance !== undefined && this.#isInstanceLive(state.instance)) continue;
750
782
  // Producer connection gone → the job it was relaying ended: release its correlation.
751
783
  this.#unlink(stream, state);
@@ -756,58 +788,98 @@ export class RelayTranscriptService {
756
788
  }
757
789
 
758
790
  /**
759
- * Defensive engine-reconcile safety net (#661): release any linked jobKey whose engine JOB park is
760
- * no longer live. The precise, fast release is the terminal `lifecycle` event
791
+ * Defensive engine-reconcile safety net (#661): release any job stream linked OR unlinked (#708) —
792
+ * whose engine JOB park is no longer live. The precise, fast release is the terminal `lifecycle` event
761
793
  * ({@link #observeTerminalLifecycle}), but an UNCLEAN worker exit (crash/kill) can skip that event —
762
794
  * and because the worker's relay connection is persistent across jobs, the disconnect release never
763
795
  * fires either, so the finished job would linger as a phantom active job on the worker's supply row.
764
796
  * This periodic pass asks the engine read model (the same {@link ElementInstanceResolver} the link
765
- * path uses at #544) whether each linked job is still parked; a job the engine no longer parks
797
+ * path uses at #544) whether each job is still parked; a job the engine no longer parks
766
798
  * (resolver returns `undefined`) is released and its transcript completed. Bounds staleness regardless
767
799
  * of whether the worker emitted a clean terminal event — and also covers a worker that emitted nothing
768
- * and merely went quiet.
800
+ * and merely went quiet. It covers UNLINKED job streams too (#708): the disconnect path (#691)
801
+ * can leave a job stream unlinked-but-still-parked with no producer, and jobKey alone resolves
802
+ * terminality, so this backstop is the only actor that can retire one whose worker never reconnects.
769
803
  *
770
804
  * Advisory and best-effort: a no-op with no resolver wired, and a resolver THROW / REJECTION for a
771
- * given job is treated as "unknown — keep it linked" (never a false release of a genuinely active
772
- * job). The linked set is snapshotted before any await so a concurrent completion (a terminal
805
+ * given job is treated as "unknown — keep it" (never a false release of a genuinely active
806
+ * job). The job-stream set is snapshotted before any await so a concurrent completion (a terminal
773
807
  * lifecycle event landing mid-pass) cannot corrupt iteration, and each release re-checks the current
774
808
  * stream state so a job already released between snapshot and resolution is not double-completed.
775
809
  */
776
810
  async reconcileEngineCorrelations(): Promise<void> {
777
- const resolve = this.#resolveElementInstance;
778
- if (resolve === undefined) return;
779
- const linked: { stream: string; jobKey: string; processInstanceKey?: string }[] = [];
811
+ if (this.#resolveElementInstance === undefined) return;
812
+ // Snapshot the job-stream ids BEFORE any await so a concurrent completion (a terminal lifecycle
813
+ // event, a supersede, or a disconnect-triggered engine reconcile landing mid-pass) cannot corrupt
814
+ // iteration; the per-stream helper re-reads live state, so a job released between snapshot and
815
+ // resolution is not double-completed.
816
+ const streams: string[] = [];
780
817
  for (const [stream, state] of this.#streams) {
781
- if (!state.linked || state.completed) continue;
782
- const jobKey = jobKeyOfStream(stream);
783
- if (jobKey === undefined) continue;
784
- const processInstanceKey = this.#correlation()?.resolve?.(jobKey)?.processInstanceKey;
785
- linked.push({ stream, jobKey, processInstanceKey });
818
+ if (state.completed) continue;
819
+ if (jobKeyOfStream(stream) === undefined) continue;
820
+ // Include UNLINKED job streams too (#708). The disconnect path (#691) routes an unlinked
821
+ // job stream through the engine reconcile and clears `state.producer`, so if the engine
822
+ // reports "still parked" at disconnect (or the read faults transiently) and the worker never
823
+ // reconnects to `produce` a link, this periodic pass is the ONLY actor left that can retire
824
+ // it. jobKey alone resolves terminality (as at link time), so gating this snapshot on
825
+ // `state.linked` would leak such a stream live forever once its engine job becomes terminal.
826
+ streams.push(stream);
786
827
  }
787
- for (const { stream, jobKey, processInstanceKey } of linked) {
788
- let activeKey: string | undefined;
789
- try {
790
- activeKey = await resolve(jobKey, processInstanceKey);
791
- } catch (err) {
792
- // A transient engine read failure must NOT be read as "job gone" leave the job linked; a
793
- // later pass (or the terminal lifecycle event) releases it. Advisory, never a false release.
794
- this.#log.warn("agentic relay engine-reconcile read failed leaving correlation linked", {
795
- stream,
796
- jobKey,
797
- err: String(err),
798
- });
799
- continue;
800
- }
801
- // A live JOB park (a resolved element-instance key) means the job is genuinely active keep it.
802
- if (activeKey !== undefined) continue;
803
- // The engine no longer parks this job → it ended (possibly via an unclean exit that skipped the
804
- // terminal lifecycle event). Re-check the current state a concurrent completion may already
805
- // have released it then release its correlation and flush its transcript.
806
- const current = this.#streams.get(stream);
807
- if (current === undefined || current.completed || !current.linked) continue;
808
- this.#log.info("agentic relay engine-reconcile released a stale correlation", { stream, jobKey });
809
- this.completeStream(stream);
828
+ for (const stream of streams) await this.#reconcileStreamAgainstEngine(stream);
829
+ }
830
+
831
+ /**
832
+ * Reconcile ONE `job:<jobKey>` stream against the engine's view of its job (the poller-owned
833
+ * completion authority, #691). Asks the engine read model (the {@link ElementInstanceResolver} the
834
+ * #544 link path uses) whether the job is still parked: still parked genuinely active, kept live;
835
+ * gone → ended (a clean completion whose terminal lifecycle event was missed, or an unclean exit) →
836
+ * released + its transcript flushed/archived. This is the single canonical engine-reconcile step,
837
+ * shared by BOTH the periodic safety-net pass ({@link reconcileEngineCorrelations}) and the
838
+ * disconnect-driven `#reconcile` — so a producer disconnect no longer completes a stream by inferring
839
+ * job-end from relay-connection/presence liveness (#689/#690), but by the authoritative engine
840
+ * job-state. A no-op with no resolver wired, and a resolver THROW / REJECTION is treated as
841
+ * "unknown — keep it" so a transient engine read never falsely releases a genuinely active
842
+ * job (a later pass, or the terminal lifecycle event, releases it). Re-reads live state before
843
+ * completing so a job released between the read and the completion is not double-completed.
844
+ *
845
+ * Does NOT require `state.linked`: the disconnect path (#691) also routes an UNLINKED job stream
846
+ * here (a job stream whose link deferred on the register/produce race), so the engine — not the
847
+ * link flag — owns its completion. The engine resolves by jobKey alone (as at link time); an
848
+ * unlinked stream the engine says is gone is still flushed/archived, and `#unlink` inside
849
+ * `completeStream` stays a no-op for it.
850
+ */
851
+ async #reconcileStreamAgainstEngine(stream: string): Promise<void> {
852
+ const resolve = this.#resolveElementInstance;
853
+ if (resolve === undefined) return;
854
+ const before = this.#streams.get(stream);
855
+ if (before === undefined || before.completed) return;
856
+ const jobKey = jobKeyOfStream(stream);
857
+ if (jobKey === undefined) return;
858
+ const processInstanceKey = this.#correlation()?.resolve?.(jobKey)?.processInstanceKey;
859
+ let activeKey: string | undefined;
860
+ try {
861
+ activeKey = await resolve(jobKey, processInstanceKey);
862
+ } catch (err) {
863
+ // A transient engine read failure must NOT be read as "job gone" — keep the stream live; a
864
+ // later pass (or the terminal lifecycle event) releases it. Advisory, never a false release.
865
+ this.#log.warn("agentic relay engine-reconcile read failed — keeping stream live", {
866
+ stream,
867
+ jobKey,
868
+ err: String(err),
869
+ });
870
+ return;
810
871
  }
872
+ // A live JOB park (a resolved element-instance key) means the job is genuinely active — keep it.
873
+ // This is what spares a mid-job RECONNECT: the harness still holds the engine lease, so the job is
874
+ // still parked even though the old producer connection dropped.
875
+ if (activeKey !== undefined) return;
876
+ // The engine no longer parks this job → it ended (possibly via an unclean exit that skipped the
877
+ // terminal lifecycle event). Re-check the current state — a concurrent completion may already
878
+ // have released it — then release its correlation and flush its transcript.
879
+ const current = this.#streams.get(stream);
880
+ if (current === undefined || current.completed) return;
881
+ this.#log.info("agentic relay engine-reconcile released a stale correlation", { stream, jobKey });
882
+ this.completeStream(stream);
811
883
  }
812
884
 
813
885
  /**
@@ -886,10 +958,11 @@ export function createRelayFamily(options: {
886
958
  // are read per call, so this works regardless of family mount order (relay may mount before
887
959
  // presence/correlation). Absent registries → no linking, still advisory-correct.
888
960
  instanceForConnection: (connectionId) => currentPresenceRegistry()?.instanceForConnection(connectionId),
889
- // #689: is the producing worker instance still live on ANY connection? Gates the
890
- // disconnect-driven reconcile so a mid-job RECONNECT (old producer connection dropped, the
891
- // same instance re-registered) does not archive a still-active job's stream and wedge its
892
- // correlation. Read per call for the same mount-order independence as the resolvers above.
961
+ // #689/#691: is the producing worker instance still live on ANY connection? Since #691 the
962
+ // disconnect-driven reconcile decides completion by the engine job-state (below) whenever the
963
+ // element-instance resolver is wired; this presence signal is the engine-LESS fallback that
964
+ // spares a mid-job RECONNECT's still-active stream where no engine view is available. Read per
965
+ // call for the same mount-order independence as the resolvers around it.
893
966
  isInstanceLive: (instance) => currentPresenceRegistry()?.isInstanceLive(instance) ?? false,
894
967
  // #485: resolve a completed job's worker attribution (presence identity/host) from the live
895
968
  // presence registry, read per call for the same mount-order independence. Absent → attribution
package/package.json CHANGED
@@ -1,6 +1,6 @@
1
1
  {
2
2
  "name": "@nanobpm/nano-workforce",
3
- "version": "0.174.1",
3
+ "version": "0.175.0",
4
4
  "description": "Nano Workforce — an Agent Graph Orchestration application for Agentic SDLC: durable BPMN processes that coordinate a graph of AI agents across the software delivery lifecycle.",
5
5
  "type": "module",
6
6
  "main": "main.ts",