@miradorlabs/web-grpc 2.45.0 → 2.48.0
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/google/protobuf/duration.ts +209 -0
- package/package.json +1 -1
- package/proto/gateway/common/v1/attribute_value_pb.js +7 -13
- package/proto/gateway/common/v1/status_pb.js +3 -9
- package/proto/gateway/common/v1/types_pb.js +3 -9
- package/proto/gateway/web/v1/account_gateway_pb.js +178 -184
- package/proto/gateway/web/v1/ai_gateway.ts +3384 -137
- package/proto/gateway/web/v1/ai_gateway_grpc_pb.js +154 -2
- package/proto/gateway/web/v1/ai_gateway_pb.js +10161 -4112
- package/proto/gateway/web/v1/attribute_value_pb.js +7 -13
- package/proto/gateway/web/v1/chain_gateway_pb.js +102 -108
- package/proto/gateway/web/v1/common_pb.js +1 -7
- package/proto/gateway/web/v1/derived_metric_gateway_pb.js +63 -64
- package/proto/gateway/web/v1/integration_gateway_pb.js +65 -66
- package/proto/gateway/web/v1/log_gateway_pb.js +46 -42
- package/proto/gateway/web/v1/market_gateway_pb.js +11 -17
- package/proto/gateway/web/v1/metric_gateway_pb.js +107 -103
- package/proto/gateway/web/v1/oauth_gateway_pb.js +52 -58
- package/proto/gateway/web/v1/plan_gateway_pb.js +26 -32
- package/proto/gateway/web/v1/rule_gateway_pb.js +131 -137
- package/proto/gateway/web/v1/slo_gateway_pb.js +122 -123
- package/proto/gateway/web/v1/trace_gateway_pb.js +142 -114
- package/proto/gateway/web/v1/trace_measure_gateway_pb.js +20 -24
|
@@ -13,13 +13,7 @@
|
|
|
13
13
|
|
|
14
14
|
var jspb = require('google-protobuf');
|
|
15
15
|
var goog = jspb;
|
|
16
|
-
var global =
|
|
17
|
-
(typeof globalThis !== 'undefined' && globalThis) ||
|
|
18
|
-
(typeof window !== 'undefined' && window) ||
|
|
19
|
-
(typeof global !== 'undefined' && global) ||
|
|
20
|
-
(typeof self !== 'undefined' && self) ||
|
|
21
|
-
(function () { return this; }).call(null) ||
|
|
22
|
-
Function('return this')();
|
|
16
|
+
var global = globalThis;
|
|
23
17
|
|
|
24
18
|
goog.exportSymbol('proto.gateway.web.v1.EnabledStatus', null, global);
|
|
25
19
|
/**
|
|
@@ -13,13 +13,7 @@
|
|
|
13
13
|
|
|
14
14
|
var jspb = require('google-protobuf');
|
|
15
15
|
var goog = jspb;
|
|
16
|
-
var global =
|
|
17
|
-
(typeof globalThis !== 'undefined' && globalThis) ||
|
|
18
|
-
(typeof window !== 'undefined' && window) ||
|
|
19
|
-
(typeof global !== 'undefined' && global) ||
|
|
20
|
-
(typeof self !== 'undefined' && self) ||
|
|
21
|
-
(function () { return this; }).call(null) ||
|
|
22
|
-
Function('return this')();
|
|
16
|
+
var global = globalThis;
|
|
23
17
|
|
|
24
18
|
var google_protobuf_timestamp_pb = require('google-protobuf/google/protobuf/timestamp_pb.js');
|
|
25
19
|
goog.object.extend(proto, google_protobuf_timestamp_pb);
|
|
@@ -503,7 +497,7 @@ source: jspb.Message.getFieldWithDefault(msg, 13, 0)
|
|
|
503
497
|
|
|
504
498
|
/**
|
|
505
499
|
* Deserializes binary data (in protobuf wire format).
|
|
506
|
-
* @param {jspb.ByteSource} bytes The bytes to deserialize.
|
|
500
|
+
* @param {jspb.binary.bytesource.ByteSource} bytes The bytes to deserialize.
|
|
507
501
|
* @return {!proto.gateway.web.v1.DerivedMetric}
|
|
508
502
|
*/
|
|
509
503
|
proto.gateway.web.v1.DerivedMetric.deserializeBinary = function(bytes) {
|
|
@@ -528,27 +522,27 @@ proto.gateway.web.v1.DerivedMetric.deserializeBinaryFromReader = function(msg, r
|
|
|
528
522
|
var field = reader.getFieldNumber();
|
|
529
523
|
switch (field) {
|
|
530
524
|
case 1:
|
|
531
|
-
var value = /** @type {string} */ (reader.
|
|
525
|
+
var value = /** @type {string} */ (reader.readStringRequireUtf8());
|
|
532
526
|
msg.setId(value);
|
|
533
527
|
break;
|
|
534
528
|
case 2:
|
|
535
|
-
var value = /** @type {string} */ (reader.
|
|
529
|
+
var value = /** @type {string} */ (reader.readStringRequireUtf8());
|
|
536
530
|
msg.setOrganizationId(value);
|
|
537
531
|
break;
|
|
538
532
|
case 3:
|
|
539
|
-
var value = /** @type {string} */ (reader.
|
|
533
|
+
var value = /** @type {string} */ (reader.readStringRequireUtf8());
|
|
540
534
|
msg.setProjectId(value);
|
|
541
535
|
break;
|
|
542
536
|
case 4:
|
|
543
|
-
var value = /** @type {string} */ (reader.
|
|
537
|
+
var value = /** @type {string} */ (reader.readStringRequireUtf8());
|
|
544
538
|
msg.setSlug(value);
|
|
545
539
|
break;
|
|
546
540
|
case 5:
|
|
547
|
-
var value = /** @type {string} */ (reader.
|
|
541
|
+
var value = /** @type {string} */ (reader.readStringRequireUtf8());
|
|
548
542
|
msg.setDisplayName(value);
|
|
549
543
|
break;
|
|
550
544
|
case 6:
|
|
551
|
-
var value = /** @type {string} */ (reader.
|
|
545
|
+
var value = /** @type {string} */ (reader.readStringRequireUtf8());
|
|
552
546
|
msg.setDescription(value);
|
|
553
547
|
break;
|
|
554
548
|
case 7:
|
|
@@ -556,11 +550,11 @@ proto.gateway.web.v1.DerivedMetric.deserializeBinaryFromReader = function(msg, r
|
|
|
556
550
|
msg.setEnabled(value);
|
|
557
551
|
break;
|
|
558
552
|
case 8:
|
|
559
|
-
var value = /** @type {string} */ (reader.
|
|
553
|
+
var value = /** @type {string} */ (reader.readStringRequireUtf8());
|
|
560
554
|
msg.setMetricName(value);
|
|
561
555
|
break;
|
|
562
556
|
case 9:
|
|
563
|
-
var value = /** @type {string} */ (reader.
|
|
557
|
+
var value = /** @type {string} */ (reader.readStringRequireUtf8());
|
|
564
558
|
msg.setUnit(value);
|
|
565
559
|
break;
|
|
566
560
|
case 10:
|
|
@@ -1053,7 +1047,7 @@ dimensionsList: (f = jspb.Message.getRepeatedField(msg, 4)) == null ? undefined
|
|
|
1053
1047
|
|
|
1054
1048
|
/**
|
|
1055
1049
|
* Deserializes binary data (in protobuf wire format).
|
|
1056
|
-
* @param {jspb.ByteSource} bytes The bytes to deserialize.
|
|
1050
|
+
* @param {jspb.binary.bytesource.ByteSource} bytes The bytes to deserialize.
|
|
1057
1051
|
* @return {!proto.gateway.web.v1.DerivedMetricProgram}
|
|
1058
1052
|
*/
|
|
1059
1053
|
proto.gateway.web.v1.DerivedMetricProgram.deserializeBinary = function(bytes) {
|
|
@@ -1078,15 +1072,15 @@ proto.gateway.web.v1.DerivedMetricProgram.deserializeBinaryFromReader = function
|
|
|
1078
1072
|
var field = reader.getFieldNumber();
|
|
1079
1073
|
switch (field) {
|
|
1080
1074
|
case 1:
|
|
1081
|
-
var value = /** @type {string} */ (reader.
|
|
1075
|
+
var value = /** @type {string} */ (reader.readStringRequireUtf8());
|
|
1082
1076
|
msg.setPopulationExpression(value);
|
|
1083
1077
|
break;
|
|
1084
1078
|
case 2:
|
|
1085
|
-
var value = /** @type {string} */ (reader.
|
|
1079
|
+
var value = /** @type {string} */ (reader.readStringRequireUtf8());
|
|
1086
1080
|
msg.setValueExpression(value);
|
|
1087
1081
|
break;
|
|
1088
1082
|
case 4:
|
|
1089
|
-
var value = /** @type {string} */ (reader.
|
|
1083
|
+
var value = /** @type {string} */ (reader.readStringRequireUtf8());
|
|
1090
1084
|
msg.addDimensions(value);
|
|
1091
1085
|
break;
|
|
1092
1086
|
default:
|
|
@@ -1268,7 +1262,7 @@ source: jspb.Message.getFieldWithDefault(msg, 9, 0)
|
|
|
1268
1262
|
|
|
1269
1263
|
/**
|
|
1270
1264
|
* Deserializes binary data (in protobuf wire format).
|
|
1271
|
-
* @param {jspb.ByteSource} bytes The bytes to deserialize.
|
|
1265
|
+
* @param {jspb.binary.bytesource.ByteSource} bytes The bytes to deserialize.
|
|
1272
1266
|
* @return {!proto.gateway.web.v1.CreateDerivedMetricRequest}
|
|
1273
1267
|
*/
|
|
1274
1268
|
proto.gateway.web.v1.CreateDerivedMetricRequest.deserializeBinary = function(bytes) {
|
|
@@ -1293,23 +1287,23 @@ proto.gateway.web.v1.CreateDerivedMetricRequest.deserializeBinaryFromReader = fu
|
|
|
1293
1287
|
var field = reader.getFieldNumber();
|
|
1294
1288
|
switch (field) {
|
|
1295
1289
|
case 1:
|
|
1296
|
-
var value = /** @type {string} */ (reader.
|
|
1290
|
+
var value = /** @type {string} */ (reader.readStringRequireUtf8());
|
|
1297
1291
|
msg.setOrganizationId(value);
|
|
1298
1292
|
break;
|
|
1299
1293
|
case 2:
|
|
1300
|
-
var value = /** @type {string} */ (reader.
|
|
1294
|
+
var value = /** @type {string} */ (reader.readStringRequireUtf8());
|
|
1301
1295
|
msg.setProjectId(value);
|
|
1302
1296
|
break;
|
|
1303
1297
|
case 3:
|
|
1304
|
-
var value = /** @type {string} */ (reader.
|
|
1298
|
+
var value = /** @type {string} */ (reader.readStringRequireUtf8());
|
|
1305
1299
|
msg.setSlug(value);
|
|
1306
1300
|
break;
|
|
1307
1301
|
case 4:
|
|
1308
|
-
var value = /** @type {string} */ (reader.
|
|
1302
|
+
var value = /** @type {string} */ (reader.readStringRequireUtf8());
|
|
1309
1303
|
msg.setDisplayName(value);
|
|
1310
1304
|
break;
|
|
1311
1305
|
case 5:
|
|
1312
|
-
var value = /** @type {string} */ (reader.
|
|
1306
|
+
var value = /** @type {string} */ (reader.readStringRequireUtf8());
|
|
1313
1307
|
msg.setDescription(value);
|
|
1314
1308
|
break;
|
|
1315
1309
|
case 6:
|
|
@@ -1317,7 +1311,7 @@ proto.gateway.web.v1.CreateDerivedMetricRequest.deserializeBinaryFromReader = fu
|
|
|
1317
1311
|
msg.setEnabled(value);
|
|
1318
1312
|
break;
|
|
1319
1313
|
case 7:
|
|
1320
|
-
var value = /** @type {string} */ (reader.
|
|
1314
|
+
var value = /** @type {string} */ (reader.readStringRequireUtf8());
|
|
1321
1315
|
msg.setUnit(value);
|
|
1322
1316
|
break;
|
|
1323
1317
|
case 8:
|
|
@@ -1652,7 +1646,7 @@ derivedMetric: (f = msg.getDerivedMetric()) && proto.gateway.web.v1.DerivedMetri
|
|
|
1652
1646
|
|
|
1653
1647
|
/**
|
|
1654
1648
|
* Deserializes binary data (in protobuf wire format).
|
|
1655
|
-
* @param {jspb.ByteSource} bytes The bytes to deserialize.
|
|
1649
|
+
* @param {jspb.binary.bytesource.ByteSource} bytes The bytes to deserialize.
|
|
1656
1650
|
* @return {!proto.gateway.web.v1.CreateDerivedMetricResponse}
|
|
1657
1651
|
*/
|
|
1658
1652
|
proto.gateway.web.v1.CreateDerivedMetricResponse.deserializeBinary = function(bytes) {
|
|
@@ -1855,7 +1849,7 @@ derivedMetricId: jspb.Message.getFieldWithDefault(msg, 3, "")
|
|
|
1855
1849
|
|
|
1856
1850
|
/**
|
|
1857
1851
|
* Deserializes binary data (in protobuf wire format).
|
|
1858
|
-
* @param {jspb.ByteSource} bytes The bytes to deserialize.
|
|
1852
|
+
* @param {jspb.binary.bytesource.ByteSource} bytes The bytes to deserialize.
|
|
1859
1853
|
* @return {!proto.gateway.web.v1.GetDerivedMetricRequest}
|
|
1860
1854
|
*/
|
|
1861
1855
|
proto.gateway.web.v1.GetDerivedMetricRequest.deserializeBinary = function(bytes) {
|
|
@@ -1880,15 +1874,15 @@ proto.gateway.web.v1.GetDerivedMetricRequest.deserializeBinaryFromReader = funct
|
|
|
1880
1874
|
var field = reader.getFieldNumber();
|
|
1881
1875
|
switch (field) {
|
|
1882
1876
|
case 1:
|
|
1883
|
-
var value = /** @type {string} */ (reader.
|
|
1877
|
+
var value = /** @type {string} */ (reader.readStringRequireUtf8());
|
|
1884
1878
|
msg.setOrganizationId(value);
|
|
1885
1879
|
break;
|
|
1886
1880
|
case 2:
|
|
1887
|
-
var value = /** @type {string} */ (reader.
|
|
1881
|
+
var value = /** @type {string} */ (reader.readStringRequireUtf8());
|
|
1888
1882
|
msg.setProjectId(value);
|
|
1889
1883
|
break;
|
|
1890
1884
|
case 3:
|
|
1891
|
-
var value = /** @type {string} */ (reader.
|
|
1885
|
+
var value = /** @type {string} */ (reader.readStringRequireUtf8());
|
|
1892
1886
|
msg.setDerivedMetricId(value);
|
|
1893
1887
|
break;
|
|
1894
1888
|
default:
|
|
@@ -2044,7 +2038,7 @@ derivedMetric: (f = msg.getDerivedMetric()) && proto.gateway.web.v1.DerivedMetri
|
|
|
2044
2038
|
|
|
2045
2039
|
/**
|
|
2046
2040
|
* Deserializes binary data (in protobuf wire format).
|
|
2047
|
-
* @param {jspb.ByteSource} bytes The bytes to deserialize.
|
|
2041
|
+
* @param {jspb.binary.bytesource.ByteSource} bytes The bytes to deserialize.
|
|
2048
2042
|
* @return {!proto.gateway.web.v1.GetDerivedMetricResponse}
|
|
2049
2043
|
*/
|
|
2050
2044
|
proto.gateway.web.v1.GetDerivedMetricResponse.deserializeBinary = function(bytes) {
|
|
@@ -2246,7 +2240,7 @@ projectId: jspb.Message.getFieldWithDefault(msg, 2, "")
|
|
|
2246
2240
|
|
|
2247
2241
|
/**
|
|
2248
2242
|
* Deserializes binary data (in protobuf wire format).
|
|
2249
|
-
* @param {jspb.ByteSource} bytes The bytes to deserialize.
|
|
2243
|
+
* @param {jspb.binary.bytesource.ByteSource} bytes The bytes to deserialize.
|
|
2250
2244
|
* @return {!proto.gateway.web.v1.ListDerivedMetricsRequest}
|
|
2251
2245
|
*/
|
|
2252
2246
|
proto.gateway.web.v1.ListDerivedMetricsRequest.deserializeBinary = function(bytes) {
|
|
@@ -2271,11 +2265,11 @@ proto.gateway.web.v1.ListDerivedMetricsRequest.deserializeBinaryFromReader = fun
|
|
|
2271
2265
|
var field = reader.getFieldNumber();
|
|
2272
2266
|
switch (field) {
|
|
2273
2267
|
case 1:
|
|
2274
|
-
var value = /** @type {string} */ (reader.
|
|
2268
|
+
var value = /** @type {string} */ (reader.readStringRequireUtf8());
|
|
2275
2269
|
msg.setOrganizationId(value);
|
|
2276
2270
|
break;
|
|
2277
2271
|
case 2:
|
|
2278
|
-
var value = /** @type {string} */ (reader.
|
|
2272
|
+
var value = /** @type {string} */ (reader.readStringRequireUtf8());
|
|
2279
2273
|
msg.setProjectId(value);
|
|
2280
2274
|
break;
|
|
2281
2275
|
default:
|
|
@@ -2414,7 +2408,7 @@ derivedMetricsList: jspb.Message.toObjectList(msg.getDerivedMetricsList(),
|
|
|
2414
2408
|
|
|
2415
2409
|
/**
|
|
2416
2410
|
* Deserializes binary data (in protobuf wire format).
|
|
2417
|
-
* @param {jspb.ByteSource} bytes The bytes to deserialize.
|
|
2411
|
+
* @param {jspb.binary.bytesource.ByteSource} bytes The bytes to deserialize.
|
|
2418
2412
|
* @return {!proto.gateway.web.v1.ListDerivedMetricsResponse}
|
|
2419
2413
|
*/
|
|
2420
2414
|
proto.gateway.web.v1.ListDerivedMetricsResponse.deserializeBinary = function(bytes) {
|
|
@@ -2619,7 +2613,7 @@ updates: (f = msg.getUpdates()) && proto.gateway.web.v1.UpdateDerivedMetricReque
|
|
|
2619
2613
|
|
|
2620
2614
|
/**
|
|
2621
2615
|
* Deserializes binary data (in protobuf wire format).
|
|
2622
|
-
* @param {jspb.ByteSource} bytes The bytes to deserialize.
|
|
2616
|
+
* @param {jspb.binary.bytesource.ByteSource} bytes The bytes to deserialize.
|
|
2623
2617
|
* @return {!proto.gateway.web.v1.UpdateDerivedMetricRequest}
|
|
2624
2618
|
*/
|
|
2625
2619
|
proto.gateway.web.v1.UpdateDerivedMetricRequest.deserializeBinary = function(bytes) {
|
|
@@ -2644,15 +2638,15 @@ proto.gateway.web.v1.UpdateDerivedMetricRequest.deserializeBinaryFromReader = fu
|
|
|
2644
2638
|
var field = reader.getFieldNumber();
|
|
2645
2639
|
switch (field) {
|
|
2646
2640
|
case 1:
|
|
2647
|
-
var value = /** @type {string} */ (reader.
|
|
2641
|
+
var value = /** @type {string} */ (reader.readStringRequireUtf8());
|
|
2648
2642
|
msg.setOrganizationId(value);
|
|
2649
2643
|
break;
|
|
2650
2644
|
case 2:
|
|
2651
|
-
var value = /** @type {string} */ (reader.
|
|
2645
|
+
var value = /** @type {string} */ (reader.readStringRequireUtf8());
|
|
2652
2646
|
msg.setProjectId(value);
|
|
2653
2647
|
break;
|
|
2654
2648
|
case 3:
|
|
2655
|
-
var value = /** @type {string} */ (reader.
|
|
2649
|
+
var value = /** @type {string} */ (reader.readStringRequireUtf8());
|
|
2656
2650
|
msg.setDerivedMetricId(value);
|
|
2657
2651
|
break;
|
|
2658
2652
|
case 4:
|
|
@@ -2770,7 +2764,7 @@ valueExpression: (f = jspb.Message.getField(msg, 5)) == null ? undefined : f
|
|
|
2770
2764
|
|
|
2771
2765
|
/**
|
|
2772
2766
|
* Deserializes binary data (in protobuf wire format).
|
|
2773
|
-
* @param {jspb.ByteSource} bytes The bytes to deserialize.
|
|
2767
|
+
* @param {jspb.binary.bytesource.ByteSource} bytes The bytes to deserialize.
|
|
2774
2768
|
* @return {!proto.gateway.web.v1.UpdateDerivedMetricRequest.DerivedMetricUpdates}
|
|
2775
2769
|
*/
|
|
2776
2770
|
proto.gateway.web.v1.UpdateDerivedMetricRequest.DerivedMetricUpdates.deserializeBinary = function(bytes) {
|
|
@@ -2795,11 +2789,11 @@ proto.gateway.web.v1.UpdateDerivedMetricRequest.DerivedMetricUpdates.deserialize
|
|
|
2795
2789
|
var field = reader.getFieldNumber();
|
|
2796
2790
|
switch (field) {
|
|
2797
2791
|
case 1:
|
|
2798
|
-
var value = /** @type {string} */ (reader.
|
|
2792
|
+
var value = /** @type {string} */ (reader.readStringRequireUtf8());
|
|
2799
2793
|
msg.setDisplayName(value);
|
|
2800
2794
|
break;
|
|
2801
2795
|
case 2:
|
|
2802
|
-
var value = /** @type {string} */ (reader.
|
|
2796
|
+
var value = /** @type {string} */ (reader.readStringRequireUtf8());
|
|
2803
2797
|
msg.setDescription(value);
|
|
2804
2798
|
break;
|
|
2805
2799
|
case 3:
|
|
@@ -2807,11 +2801,11 @@ proto.gateway.web.v1.UpdateDerivedMetricRequest.DerivedMetricUpdates.deserialize
|
|
|
2807
2801
|
msg.setEnabled(value);
|
|
2808
2802
|
break;
|
|
2809
2803
|
case 4:
|
|
2810
|
-
var value = /** @type {string} */ (reader.
|
|
2804
|
+
var value = /** @type {string} */ (reader.readStringRequireUtf8());
|
|
2811
2805
|
msg.setPopulationExpression(value);
|
|
2812
2806
|
break;
|
|
2813
2807
|
case 5:
|
|
2814
|
-
var value = /** @type {string} */ (reader.
|
|
2808
|
+
var value = /** @type {string} */ (reader.readStringRequireUtf8());
|
|
2815
2809
|
msg.setValueExpression(value);
|
|
2816
2810
|
break;
|
|
2817
2811
|
default:
|
|
@@ -3198,7 +3192,7 @@ derivedMetric: (f = msg.getDerivedMetric()) && proto.gateway.web.v1.DerivedMetri
|
|
|
3198
3192
|
|
|
3199
3193
|
/**
|
|
3200
3194
|
* Deserializes binary data (in protobuf wire format).
|
|
3201
|
-
* @param {jspb.ByteSource} bytes The bytes to deserialize.
|
|
3195
|
+
* @param {jspb.binary.bytesource.ByteSource} bytes The bytes to deserialize.
|
|
3202
3196
|
* @return {!proto.gateway.web.v1.UpdateDerivedMetricResponse}
|
|
3203
3197
|
*/
|
|
3204
3198
|
proto.gateway.web.v1.UpdateDerivedMetricResponse.deserializeBinary = function(bytes) {
|
|
@@ -3401,7 +3395,7 @@ derivedMetricId: jspb.Message.getFieldWithDefault(msg, 3, "")
|
|
|
3401
3395
|
|
|
3402
3396
|
/**
|
|
3403
3397
|
* Deserializes binary data (in protobuf wire format).
|
|
3404
|
-
* @param {jspb.ByteSource} bytes The bytes to deserialize.
|
|
3398
|
+
* @param {jspb.binary.bytesource.ByteSource} bytes The bytes to deserialize.
|
|
3405
3399
|
* @return {!proto.gateway.web.v1.DeleteDerivedMetricRequest}
|
|
3406
3400
|
*/
|
|
3407
3401
|
proto.gateway.web.v1.DeleteDerivedMetricRequest.deserializeBinary = function(bytes) {
|
|
@@ -3426,15 +3420,15 @@ proto.gateway.web.v1.DeleteDerivedMetricRequest.deserializeBinaryFromReader = fu
|
|
|
3426
3420
|
var field = reader.getFieldNumber();
|
|
3427
3421
|
switch (field) {
|
|
3428
3422
|
case 1:
|
|
3429
|
-
var value = /** @type {string} */ (reader.
|
|
3423
|
+
var value = /** @type {string} */ (reader.readStringRequireUtf8());
|
|
3430
3424
|
msg.setOrganizationId(value);
|
|
3431
3425
|
break;
|
|
3432
3426
|
case 2:
|
|
3433
|
-
var value = /** @type {string} */ (reader.
|
|
3427
|
+
var value = /** @type {string} */ (reader.readStringRequireUtf8());
|
|
3434
3428
|
msg.setProjectId(value);
|
|
3435
3429
|
break;
|
|
3436
3430
|
case 3:
|
|
3437
|
-
var value = /** @type {string} */ (reader.
|
|
3431
|
+
var value = /** @type {string} */ (reader.readStringRequireUtf8());
|
|
3438
3432
|
msg.setDerivedMetricId(value);
|
|
3439
3433
|
break;
|
|
3440
3434
|
default:
|
|
@@ -3589,7 +3583,7 @@ status: (f = msg.getStatus()) && proto_gateway_common_v1_status_pb.ResponseStatu
|
|
|
3589
3583
|
|
|
3590
3584
|
/**
|
|
3591
3585
|
* Deserializes binary data (in protobuf wire format).
|
|
3592
|
-
* @param {jspb.ByteSource} bytes The bytes to deserialize.
|
|
3586
|
+
* @param {jspb.binary.bytesource.ByteSource} bytes The bytes to deserialize.
|
|
3593
3587
|
* @return {!proto.gateway.web.v1.DeleteDerivedMetricResponse}
|
|
3594
3588
|
*/
|
|
3595
3589
|
proto.gateway.web.v1.DeleteDerivedMetricResponse.deserializeBinary = function(bytes) {
|
|
@@ -3743,7 +3737,7 @@ traceLimit: jspb.Message.getFieldWithDefault(msg, 4, 0)
|
|
|
3743
3737
|
|
|
3744
3738
|
/**
|
|
3745
3739
|
* Deserializes binary data (in protobuf wire format).
|
|
3746
|
-
* @param {jspb.ByteSource} bytes The bytes to deserialize.
|
|
3740
|
+
* @param {jspb.binary.bytesource.ByteSource} bytes The bytes to deserialize.
|
|
3747
3741
|
* @return {!proto.gateway.web.v1.DryRunDerivedMetricRequest}
|
|
3748
3742
|
*/
|
|
3749
3743
|
proto.gateway.web.v1.DryRunDerivedMetricRequest.deserializeBinary = function(bytes) {
|
|
@@ -3768,11 +3762,11 @@ proto.gateway.web.v1.DryRunDerivedMetricRequest.deserializeBinaryFromReader = fu
|
|
|
3768
3762
|
var field = reader.getFieldNumber();
|
|
3769
3763
|
switch (field) {
|
|
3770
3764
|
case 1:
|
|
3771
|
-
var value = /** @type {string} */ (reader.
|
|
3765
|
+
var value = /** @type {string} */ (reader.readStringRequireUtf8());
|
|
3772
3766
|
msg.setOrganizationId(value);
|
|
3773
3767
|
break;
|
|
3774
3768
|
case 2:
|
|
3775
|
-
var value = /** @type {string} */ (reader.
|
|
3769
|
+
var value = /** @type {string} */ (reader.readStringRequireUtf8());
|
|
3776
3770
|
msg.setProjectId(value);
|
|
3777
3771
|
break;
|
|
3778
3772
|
case 3:
|
|
@@ -3993,7 +3987,7 @@ tracesSelected: jspb.Message.getFieldWithDefault(msg, 4, 0)
|
|
|
3993
3987
|
|
|
3994
3988
|
/**
|
|
3995
3989
|
* Deserializes binary data (in protobuf wire format).
|
|
3996
|
-
* @param {jspb.ByteSource} bytes The bytes to deserialize.
|
|
3990
|
+
* @param {jspb.binary.bytesource.ByteSource} bytes The bytes to deserialize.
|
|
3997
3991
|
* @return {!proto.gateway.web.v1.DryRunDerivedMetricResponse}
|
|
3998
3992
|
*/
|
|
3999
3993
|
proto.gateway.web.v1.DryRunDerivedMetricResponse.deserializeBinary = function(bytes) {
|
|
@@ -4303,7 +4297,7 @@ notEmitted: (f = msg.getNotEmitted()) && proto.gateway.web.v1.DryRunNonEmission.
|
|
|
4303
4297
|
|
|
4304
4298
|
/**
|
|
4305
4299
|
* Deserializes binary data (in protobuf wire format).
|
|
4306
|
-
* @param {jspb.ByteSource} bytes The bytes to deserialize.
|
|
4300
|
+
* @param {jspb.binary.bytesource.ByteSource} bytes The bytes to deserialize.
|
|
4307
4301
|
* @return {!proto.gateway.web.v1.DryRunTraceResult}
|
|
4308
4302
|
*/
|
|
4309
4303
|
proto.gateway.web.v1.DryRunTraceResult.deserializeBinary = function(bytes) {
|
|
@@ -4328,7 +4322,7 @@ proto.gateway.web.v1.DryRunTraceResult.deserializeBinaryFromReader = function(ms
|
|
|
4328
4322
|
var field = reader.getFieldNumber();
|
|
4329
4323
|
switch (field) {
|
|
4330
4324
|
case 1:
|
|
4331
|
-
var value = /** @type {string} */ (reader.
|
|
4325
|
+
var value = /** @type {string} */ (reader.readStringRequireUtf8());
|
|
4332
4326
|
msg.setTraceId(value);
|
|
4333
4327
|
break;
|
|
4334
4328
|
case 2:
|
|
@@ -4534,7 +4528,7 @@ resolvedDimensionsMap: (f = msg.getResolvedDimensionsMap()) ? f.toObject(include
|
|
|
4534
4528
|
|
|
4535
4529
|
/**
|
|
4536
4530
|
* Deserializes binary data (in protobuf wire format).
|
|
4537
|
-
* @param {jspb.ByteSource} bytes The bytes to deserialize.
|
|
4531
|
+
* @param {jspb.binary.bytesource.ByteSource} bytes The bytes to deserialize.
|
|
4538
4532
|
* @return {!proto.gateway.web.v1.DryRunEmission}
|
|
4539
4533
|
*/
|
|
4540
4534
|
proto.gateway.web.v1.DryRunEmission.deserializeBinary = function(bytes) {
|
|
@@ -4565,7 +4559,7 @@ proto.gateway.web.v1.DryRunEmission.deserializeBinaryFromReader = function(msg,
|
|
|
4565
4559
|
case 3:
|
|
4566
4560
|
var value = msg.getResolvedDimensionsMap();
|
|
4567
4561
|
reader.readMessage(value, function(message, reader) {
|
|
4568
|
-
jspb.Map.deserializeBinary(message, reader, jspb.BinaryReader.prototype.
|
|
4562
|
+
jspb.Map.deserializeBinary(message, reader, jspb.BinaryReader.prototype.readStringRequireUtf8, jspb.BinaryReader.prototype.readStringRequireUtf8, null, "", "");
|
|
4569
4563
|
});
|
|
4570
4564
|
break;
|
|
4571
4565
|
default:
|
|
@@ -4606,7 +4600,12 @@ proto.gateway.web.v1.DryRunEmission.serializeBinaryToWriter = function(message,
|
|
|
4606
4600
|
}
|
|
4607
4601
|
f = message.getResolvedDimensionsMap(true);
|
|
4608
4602
|
if (f && f.getLength() > 0) {
|
|
4609
|
-
|
|
4603
|
+
jspb.internal.public_for_gencode.serializeMapToBinary(
|
|
4604
|
+
message.getResolvedDimensionsMap(true),
|
|
4605
|
+
3,
|
|
4606
|
+
writer,
|
|
4607
|
+
jspb.BinaryWriter.prototype.writeString,
|
|
4608
|
+
jspb.BinaryWriter.prototype.writeString);
|
|
4610
4609
|
}
|
|
4611
4610
|
};
|
|
4612
4611
|
|
|
@@ -4698,7 +4697,7 @@ detail: jspb.Message.getFieldWithDefault(msg, 2, "")
|
|
|
4698
4697
|
|
|
4699
4698
|
/**
|
|
4700
4699
|
* Deserializes binary data (in protobuf wire format).
|
|
4701
|
-
* @param {jspb.ByteSource} bytes The bytes to deserialize.
|
|
4700
|
+
* @param {jspb.binary.bytesource.ByteSource} bytes The bytes to deserialize.
|
|
4702
4701
|
* @return {!proto.gateway.web.v1.DryRunNonEmission}
|
|
4703
4702
|
*/
|
|
4704
4703
|
proto.gateway.web.v1.DryRunNonEmission.deserializeBinary = function(bytes) {
|
|
@@ -4727,7 +4726,7 @@ proto.gateway.web.v1.DryRunNonEmission.deserializeBinaryFromReader = function(ms
|
|
|
4727
4726
|
msg.setOutcome(value);
|
|
4728
4727
|
break;
|
|
4729
4728
|
case 2:
|
|
4730
|
-
var value = /** @type {string} */ (reader.
|
|
4729
|
+
var value = /** @type {string} */ (reader.readStringRequireUtf8());
|
|
4731
4730
|
msg.setDetail(value);
|
|
4732
4731
|
break;
|
|
4733
4732
|
default:
|
|
@@ -4858,7 +4857,7 @@ count: jspb.Message.getFieldWithDefault(msg, 2, 0)
|
|
|
4858
4857
|
|
|
4859
4858
|
/**
|
|
4860
4859
|
* Deserializes binary data (in protobuf wire format).
|
|
4861
|
-
* @param {jspb.ByteSource} bytes The bytes to deserialize.
|
|
4860
|
+
* @param {jspb.binary.bytesource.ByteSource} bytes The bytes to deserialize.
|
|
4862
4861
|
* @return {!proto.gateway.web.v1.DerivedMetricOutcomeCount}
|
|
4863
4862
|
*/
|
|
4864
4863
|
proto.gateway.web.v1.DerivedMetricOutcomeCount.deserializeBinary = function(bytes) {
|