@mega-yfue/eufy-sdk 0.2.0-beta.22 → 0.2.0-beta.23
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
package/dist/index.js
CHANGED
|
@@ -27155,45 +27155,79 @@ var SolixClient = class _SolixClient {
|
|
|
27155
27155
|
import { EventEmitter as EventEmitter10 } from "node:events";
|
|
27156
27156
|
var SOLIX_METER_FIELD_NAMES = {
|
|
27157
27157
|
168: "meterPowerL1",
|
|
27158
|
+
// Anker Modbus: primary_phase_1_active_power
|
|
27158
27159
|
169: "meterPowerL2",
|
|
27160
|
+
// Anker Modbus: primary_phase_2_active_power
|
|
27159
27161
|
170: "meterPowerL3",
|
|
27162
|
+
// Anker Modbus: primary_phase_3_active_power
|
|
27160
27163
|
171: "meterPowerTotal",
|
|
27164
|
+
// Anker Modbus: primary_total_active_power
|
|
27161
27165
|
172: "meterVoltageL1",
|
|
27166
|
+
// Anker Modbus: primary_phase_1_voltage
|
|
27162
27167
|
173: "meterVoltageL2",
|
|
27168
|
+
// Anker Modbus: primary_phase_2_voltage
|
|
27163
27169
|
174: "meterVoltageL3",
|
|
27170
|
+
// Anker Modbus: primary_phase_3_voltage
|
|
27164
27171
|
175: "meterCurrentL1",
|
|
27172
|
+
// Anker Modbus: primary_phase_1_current
|
|
27165
27173
|
176: "meterCurrentL2",
|
|
27174
|
+
// Anker Modbus: primary_phase_2_current
|
|
27166
27175
|
177: "meterCurrentL3",
|
|
27176
|
+
// Anker Modbus: primary_phase_3_current
|
|
27167
27177
|
179: "meterImportEnergy",
|
|
27178
|
+
// Anker Modbus: primary_total_forward_active_energy
|
|
27168
27179
|
180: "meterExportEnergy"
|
|
27180
|
+
// Anker Modbus: primary_total_reverse_active_energy
|
|
27169
27181
|
};
|
|
27170
27182
|
var SOLIX_METER_PRODUCT_PREFIXES = ["AE1X0"];
|
|
27171
27183
|
var SOLIX_SOLARBANK_PRODUCT_PREFIX = "AE10";
|
|
27172
27184
|
var SOLIX_SOLARBANK_FIELD_NAMES = {
|
|
27173
27185
|
171: "photovoltaicPower",
|
|
27174
|
-
// total PV input across the strings
|
|
27186
|
+
// total PV input across the strings — Anker Modbus: pv_power
|
|
27175
27187
|
172: "batteryPower",
|
|
27188
|
+
// signed net pack power — Anker Modbus: battery_charging_power − battery_discharging_power
|
|
27176
27189
|
188: "chargePower",
|
|
27190
|
+
// Anker Modbus: battery_charging_power
|
|
27177
27191
|
173: "dischargePower",
|
|
27192
|
+
// Anker Modbus: battery_discharging_power
|
|
27178
27193
|
174: "acPlugPower",
|
|
27194
|
+
// AC plug, signed — Anker Modbus: ac_grid_output_power
|
|
27179
27195
|
175: "socketPower",
|
|
27180
|
-
// the unit's own on-board AC socket (an appliance plugged into the Solarbank)
|
|
27196
|
+
// the unit's own on-board AC socket (an appliance plugged into the Solarbank) — no Anker register
|
|
27181
27197
|
196: "gridInputPower",
|
|
27198
|
+
// Anker Modbus: grid_import_power
|
|
27182
27199
|
197: "homeLoadPower",
|
|
27200
|
+
// Anker Modbus: load_power
|
|
27183
27201
|
198: "pv1Power",
|
|
27184
|
-
// the four PV-string inputs (0 when a string is unused / dark)
|
|
27202
|
+
// the four PV-string inputs (0 when a string is unused / dark); Anker exposes only a pv_power total
|
|
27185
27203
|
199: "pv2Power",
|
|
27186
27204
|
200: "pv3Power",
|
|
27187
27205
|
201: "pv4Power"
|
|
27188
27206
|
};
|
|
27189
27207
|
var SOLIX_STATE_FIELD_NAMES = {
|
|
27190
27208
|
169: "mode",
|
|
27191
|
-
// current operating (EMS) mode
|
|
27209
|
+
// current operating (EMS) mode, AE103 numbering: 1 custom, 2 self-consumption, 4 rapid charge, 7 smart, 8 dynamic tariff (NOT the Modbus SOLIX_MODBUS_EMS_MODES numbering)
|
|
27192
27210
|
170: "maxLoad"
|
|
27193
27211
|
// configured max home load (W) — matches get_site_device_param max_load
|
|
27194
27212
|
// NOTE `0xab` is grid-in/out-related power but its exact meaning is not yet pinned, so it stays raw
|
|
27195
27213
|
// `state_ab` (a diagnostic a consumer can watch) rather than being asserted under a guessed name.
|
|
27196
27214
|
};
|
|
27215
|
+
var SOLIX_MODBUS_EMS_MODES = {
|
|
27216
|
+
0: "selfConsumption",
|
|
27217
|
+
// Self-Consumption Mode (Anker: self_consumption, 0x8006 BIT0)
|
|
27218
|
+
1: "timeOfUse",
|
|
27219
|
+
// Time Of Use Mode (Anker: tou_mode, BIT1)
|
|
27220
|
+
3: "thirdPartyControl",
|
|
27221
|
+
// Third-Party Controlled (Anker: third_party_control, BIT5)
|
|
27222
|
+
4: "custom",
|
|
27223
|
+
// Custom Mode (Anker: custom_mode, BIT2)
|
|
27224
|
+
5: "socketOverlay",
|
|
27225
|
+
// Socket Overlay Mode (Anker: socket_overlay_mode, BIT4)
|
|
27226
|
+
6: "smart",
|
|
27227
|
+
// Smart Mode (Anker: smart_mode, BIT3)
|
|
27228
|
+
7: "dynamicTariff"
|
|
27229
|
+
// Dynamic Tariff Mode (Anker: dynamic_pricing, BIT6)
|
|
27230
|
+
};
|
|
27197
27231
|
function solixStateReadings(frame) {
|
|
27198
27232
|
const out = {};
|
|
27199
27233
|
for (const [tag2, value] of frame.fields) {
|
|
@@ -27756,6 +27790,7 @@ export {
|
|
|
27756
27790
|
SMOKE_MEMBERS,
|
|
27757
27791
|
SOLIX_ENERGY_METER_MEMBERS,
|
|
27758
27792
|
SOLIX_LOCAL_KEY_HEX,
|
|
27793
|
+
SOLIX_MODBUS_EMS_MODES,
|
|
27759
27794
|
STATE_EVENT_FIELDS,
|
|
27760
27795
|
STATION_CHANNEL3 as STATION_CHANNEL,
|
|
27761
27796
|
STATION_CHUNK_BYTES,
|