@measurequick/measurequick-report-generator 1.5.233 → 1.5.235

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
package/package.json CHANGED
@@ -1,6 +1,6 @@
1
1
  {
2
2
  "name": "@measurequick/measurequick-report-generator",
3
- "version": "1.5.233",
3
+ "version": "1.5.235",
4
4
  "description": "Generates PDF documents for various measureQuick applications.",
5
5
  "main": "index.js",
6
6
  "scripts": {
@@ -311,6 +311,8 @@ export async function getReport(payload) {
311
311
  ? measurement.value
312
312
  : +test.data[measurement.ref];
313
313
  if (!val) val = "--";
314
+ else if (measurement.ref == "sensible_heat_ratio" && typeof val == "number")
315
+ val = val.toFixed(2);
314
316
  else if (measurement.fixTo && typeof val == "number")
315
317
  val = val.toFixed(measurement.fixTo);
316
318
  if (typeof val == "number" || !isNaN(val))
@@ -538,6 +538,8 @@ export async function getReport(payload) {
538
538
  }
539
539
  } else if (!val) {
540
540
  val = "--";
541
+ } else if (measurement.ref == "sensible_heat_ratio" && typeof val == "number") {
542
+ val = val.toFixed(2);
541
543
  } else if (measurement.fixTo && typeof val == "number") {
542
544
  val = val.toFixed(measurement.fixTo);
543
545
  }
package/util.js CHANGED
@@ -299,7 +299,9 @@ export function getElectricalData(test, suffix, embeddedIcons) {
299
299
  let src = "_l1";
300
300
  let vDisplay, aDisplay, vIcon, aIcon;
301
301
 
302
- if (test.electrical_capture_type !== "Power") {
302
+ // Use the correct capture type for the section (condenser vs AHU)
303
+ let captureType = suffix ? (test[`electrical_capture_type${suffix}`] || test.electrical_capture_type) : test.electrical_capture_type;
304
+ if (captureType !== "Power") {
303
305
  if (phase === "Single") {
304
306
  if (
305
307
  (voltage == "115" || voltage == "120") &&
@@ -350,12 +352,8 @@ export function getElectricalData(test, suffix, embeddedIcons) {
350
352
  }
351
353
  } else if (
352
354
  phase === "Three" &&
353
- test.data[`voltage_l1${suffix}`] &&
354
- test.data[`voltage_l2${suffix}`] &&
355
- test.data[`voltage_l3${suffix}`] &&
356
- test.data[`amperage_l1${suffix}`] &&
357
- test.data[`amperage_l2${suffix}`] &&
358
- test.data[`amperage_l3${suffix}`]
355
+ (+test.data[`voltage_l1${suffix}`]) > 0 && (+test.data[`voltage_l2${suffix}`]) > 0 && (+test.data[`voltage_l3${suffix}`]) > 0 &&
356
+ test.data[`amperage_l1${suffix}`] && test.data[`amperage_l2${suffix}`] && test.data[`amperage_l3${suffix}`]
359
357
  ) {
360
358
  vDisplay =
361
359
  (+test.data[`voltage_l1${suffix}`]).toFixed(1) +
@@ -370,9 +368,9 @@ export function getElectricalData(test, suffix, embeddedIcons) {
370
368
  " / " +
371
369
  (+test.data[`amperage_l3${suffix}`]).toFixed(1);
372
370
  }
373
- } else if (test.electrical_capture_type === "Power") {
374
- vDisplay = (+test.data[`voltage_l1`]).toFixed(1);
375
- aDisplay = (+test.data[`amperage_l1`]).toFixed(1);
371
+ } else if (captureType === "Power") {
372
+ vDisplay = (+test.data[`voltage_l1${suffix}`]).toFixed(1);
373
+ aDisplay = (+test.data[`amperage_l1${suffix}`]).toFixed(1);
376
374
  }
377
375
 
378
376
  // Fallback: If vDisplay/aDisplay not set but data exists, use the data directly