@measurequick/measurequick-report-generator 1.5.233 → 1.5.235
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
package/package.json
CHANGED
|
@@ -311,6 +311,8 @@ export async function getReport(payload) {
|
|
|
311
311
|
? measurement.value
|
|
312
312
|
: +test.data[measurement.ref];
|
|
313
313
|
if (!val) val = "--";
|
|
314
|
+
else if (measurement.ref == "sensible_heat_ratio" && typeof val == "number")
|
|
315
|
+
val = val.toFixed(2);
|
|
314
316
|
else if (measurement.fixTo && typeof val == "number")
|
|
315
317
|
val = val.toFixed(measurement.fixTo);
|
|
316
318
|
if (typeof val == "number" || !isNaN(val))
|
|
@@ -538,6 +538,8 @@ export async function getReport(payload) {
|
|
|
538
538
|
}
|
|
539
539
|
} else if (!val) {
|
|
540
540
|
val = "--";
|
|
541
|
+
} else if (measurement.ref == "sensible_heat_ratio" && typeof val == "number") {
|
|
542
|
+
val = val.toFixed(2);
|
|
541
543
|
} else if (measurement.fixTo && typeof val == "number") {
|
|
542
544
|
val = val.toFixed(measurement.fixTo);
|
|
543
545
|
}
|
package/util.js
CHANGED
|
@@ -299,7 +299,9 @@ export function getElectricalData(test, suffix, embeddedIcons) {
|
|
|
299
299
|
let src = "_l1";
|
|
300
300
|
let vDisplay, aDisplay, vIcon, aIcon;
|
|
301
301
|
|
|
302
|
-
|
|
302
|
+
// Use the correct capture type for the section (condenser vs AHU)
|
|
303
|
+
let captureType = suffix ? (test[`electrical_capture_type${suffix}`] || test.electrical_capture_type) : test.electrical_capture_type;
|
|
304
|
+
if (captureType !== "Power") {
|
|
303
305
|
if (phase === "Single") {
|
|
304
306
|
if (
|
|
305
307
|
(voltage == "115" || voltage == "120") &&
|
|
@@ -350,12 +352,8 @@ export function getElectricalData(test, suffix, embeddedIcons) {
|
|
|
350
352
|
}
|
|
351
353
|
} else if (
|
|
352
354
|
phase === "Three" &&
|
|
353
|
-
test.data[`voltage_l1${suffix}`] &&
|
|
354
|
-
test.data[`
|
|
355
|
-
test.data[`voltage_l3${suffix}`] &&
|
|
356
|
-
test.data[`amperage_l1${suffix}`] &&
|
|
357
|
-
test.data[`amperage_l2${suffix}`] &&
|
|
358
|
-
test.data[`amperage_l3${suffix}`]
|
|
355
|
+
(+test.data[`voltage_l1${suffix}`]) > 0 && (+test.data[`voltage_l2${suffix}`]) > 0 && (+test.data[`voltage_l3${suffix}`]) > 0 &&
|
|
356
|
+
test.data[`amperage_l1${suffix}`] && test.data[`amperage_l2${suffix}`] && test.data[`amperage_l3${suffix}`]
|
|
359
357
|
) {
|
|
360
358
|
vDisplay =
|
|
361
359
|
(+test.data[`voltage_l1${suffix}`]).toFixed(1) +
|
|
@@ -370,9 +368,9 @@ export function getElectricalData(test, suffix, embeddedIcons) {
|
|
|
370
368
|
" / " +
|
|
371
369
|
(+test.data[`amperage_l3${suffix}`]).toFixed(1);
|
|
372
370
|
}
|
|
373
|
-
} else if (
|
|
374
|
-
vDisplay = (+test.data[`voltage_l1`]).toFixed(1);
|
|
375
|
-
aDisplay = (+test.data[`amperage_l1`]).toFixed(1);
|
|
371
|
+
} else if (captureType === "Power") {
|
|
372
|
+
vDisplay = (+test.data[`voltage_l1${suffix}`]).toFixed(1);
|
|
373
|
+
aDisplay = (+test.data[`amperage_l1${suffix}`]).toFixed(1);
|
|
376
374
|
}
|
|
377
375
|
|
|
378
376
|
// Fallback: If vDisplay/aDisplay not set but data exists, use the data directly
|