@mark1russell7/guidebook-preparedness 0.7.14 → 0.7.16

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
package/package.json CHANGED
@@ -1,7 +1,7 @@
1
1
  {
2
2
  "$schema": "https://json.schemastore.org/package",
3
3
  "name": "@mark1russell7/guidebook-preparedness",
4
- "version": "0.7.14",
4
+ "version": "0.7.16",
5
5
  "description": "The preparedness content of the guidebook: cited sources, the steps and marked gaps of 12 cases and 6 cuts, 40 topics in 12 areas, and the catalog of offline bundles.",
6
6
  "keywords": [
7
7
  "guidebook",
@@ -42,6 +42,8 @@ export const SOURCES: readonly Source[] = [
42
42
  { ...federal("usace-blue-roof", "U.S. Army Corps of Engineers", "Blue Roof Information", "https://www.usace.army.mil/Missions/Emergency-Operations/Blue-Roof-Information/"), checked: "2026-11-23" },
43
43
  { ...federal("nws-nwr-same", "National Weather Service", "NWR SAME", "https://www.weather.gov/nwr/nwrsame"), checked: "2026-11-23" },
44
44
  { ...federal("fcc-amateur", "Federal Communications Commission", "Amateur Radio Service", "https://www.fcc.gov/wireless/bureau-divisions/mobility-division/amateur-radio-service"), checked: "2026-11-23" },
45
+ { ...federal("niosh-lead", "NIOSH", "NIOSH Pocket Guide to Chemical Hazards: Lead", "https://www.cdc.gov/niosh/npg/npgd0368.html"), checked: "2026-11-23" },
46
+ { ...federal("niosh-naoh", "NIOSH", "NIOSH Pocket Guide to Chemical Hazards: Sodium hydroxide", "https://www.cdc.gov/niosh/npg/npgd0565.html"), checked: "2026-11-23" },
45
47
  { id: "mlp-bleeding", title: "Bleeding (MedlinePlus Medical Encyclopedia)", url: "https://medlineplus.gov/ency/article/000045.htm", license: "all-rights-reserved", checked: "2026-11-23", by: "A.D.A.M., Inc., for the U.S. National Library of Medicine" },
46
48
  { id: "mlp-dehydration", title: "Dehydration (MedlinePlus Medical Encyclopedia)", url: "https://medlineplus.gov/ency/article/000982.htm", license: "all-rights-reserved", checked: "2026-11-23", by: "A.D.A.M., Inc., for the U.S. National Library of Medicine" },
47
49
  federal("fda-drugs", "FDA", "Safe Drug Use After a Natural Disaster", "https://www.fda.gov/drugs/emergency-preparedness-drugs/safe-drug-use-after-natural-disaster"),
@@ -78,6 +80,29 @@ export const SOURCES: readonly Source[] = [
78
80
  { ...federal("hrsa-poison-help", "HRSA", "Calling Poison Help", "https://poisonhelp.hrsa.gov/faqs/calling-poison-help/index.html"), checked: "2026-11-21" },
79
81
  { ...federal("usfa-apartment", "U.S. Fire Administration", "Apartment fire safety", "https://www.usfa.fema.gov/downloads/fief/apartment_fire_safety.pdf"), checked: "2026-11-22" },
80
82
  { ...federal("cdc-co-psa", "CDC", "Avoiding Carbon Monoxide Poisoning", "https://www.cdc.gov/natural-disasters/psa-toolkit/avoiding-carbon-monoxide-poisoning.html"), checked: "2026-11-21" },
83
+ // The sources of the tab stay, read on 2026-11-22 and 2026-11-23. The code books, the pages of companies, states and cities give no open license.
84
+ // Thus their units are a summary or a fact. The booklet of FEMA has the American Red Cross as a second author, so it has no public domain mark here.
85
+ { id: "nyc-elevator", title: "Elevator Safety", url: "https://www.nyc.gov/site/buildings/safety/elevator-safety.page", license: "all-rights-reserved", checked: "2026-11-22", by: "NYC Department of Buildings" },
86
+ { id: "rwpc-water-heater", title: "How to access water from your water heater during an emergency", url: "https://www.regionalh2o.org/sites/default/files/images/Water_Heater_Hanger_English.pdf", license: "all-rights-reserved", checked: "2026-11-22", by: "Regional Water Providers Consortium" },
87
+ { id: "fema-477", title: "Food and Water in an Emergency (FEMA 477, 2004)", url: "https://www.fema.gov/pdf/library/f&web.pdf", license: "all-rights-reserved", checked: "2026-11-22", by: "FEMA and the American Red Cross" },
88
+ { id: "ncdhhs-toilet", title: "Toilet Use During an Emergency", url: "https://www.ncdhhs.gov/toilet-use-during-emergency/open", license: "all-rights-reserved", checked: "2026-11-22", by: "North Carolina Department of Health and Human Services" },
89
+ { ...federal("cdc-sanitation-emergency", "CDC (archived page)", "Potential Sanitation Solutions During an Emergency Response", "https://archive.cdc.gov/www_cdc_gov/healthywater/global/sanitation/sanitation-emergency-response.html"), checked: "2026-11-22" },
90
+ { id: "icc-ibc-door-operations", title: "2021 International Building Code, sections 1010.2 and 1010.2.4 (the code pages that Allegion posts)", url: "https://idighardware.com/wp-content/uploads/2021/09/2021-IBC-Key-Operated-Locks.pdf", license: "all-rights-reserved", checked: "2026-11-22", by: "International Code Council" },
91
+ { id: "icc-ibc-electric-locks", title: "2021 International Building Code, sections 1010.2.11 and 1010.2.12 (the code pages that Allegion posts)", url: "https://idighardware.com/wp-content/uploads/2022/04/2021-IBC-Electromagnetic-Locks.pdf", license: "all-rights-reserved", checked: "2026-11-22", by: "International Code Council" },
92
+ { id: "allegion-fail-safe", title: "Decoded: Fail Safe vs. Fail Secure, When and Where?", url: "https://www.allegion.ca/content/dam/allegion-us-2/web-documents-2/Article/Allegion_Fail_Safe_Fail_Secure_Article_112140.pdf", license: "all-rights-reserved", checked: "2026-11-22", by: "Allegion" },
93
+ { id: "schlage-deadbolts", title: "Deadbolts", url: "https://www.schlage.com/en/home/products/deadbolt/all-deadbolts.html", license: "all-rights-reserved", checked: "2026-11-22", by: "Schlage" },
94
+ { id: "kcso-door-locks", title: "Doors and locks", url: "https://kingcounty.gov/en/dept/sheriff/courts-jails-legal-system/crime-prevention-safety/home-security/door-locks", license: "all-rights-reserved", checked: "2026-11-22", by: "King County Sheriff's Office" },
95
+ { id: "icc-irc-r310", title: "2015 International Residential Code, section R310 (the text that Bilco posts)", url: "https://www.bilco.com/Content/BILCO/DownloadCenter/Documents/IRC-2015.pdf", license: "all-rights-reserved", checked: "2026-11-22", by: "International Code Council" },
96
+ { id: "iwfa-safety-film", title: "Specifying Safety and Security Window Film for Delayed Entry", url: "https://iwfa.com/wp-content/uploads/2024/09/IWFA-Safety-One-Page.pdf", license: "all-rights-reserved", checked: "2026-11-22", by: "International Window Film Association" },
97
+ { id: "fl-diy-shutters", title: "Do-It-Yourself Shutters (Homeowner's Hurricane Retrofit Guide)", url: "https://apps.floridadisaster.org/hrg/content/openings/diy_shutters.asp", license: "all-rights-reserved", checked: "2026-11-22", by: "Florida Division of Emergency Management" },
98
+ { id: "cbc-708", title: "California Building Code 2025, section 708, Fire Partitions", url: "https://gocodebook.com/library/us/ca/ca-building-code/chapter-7-fire-and-smoke-protection-features/section-708-fire-partitions", license: "all-rights-reserved", checked: "2026-11-22", by: "California Building Standards Commission, from the International Building Code" },
99
+ { id: "cbc-716", title: "California Building Code 2025, section 716, Opening Protectives", url: "https://gocodebook.com/library/us/ca/ca-building-code/chapter-7-fire-and-smoke-protection-features/section-716-opening-protectives", license: "all-rights-reserved", checked: "2026-11-22", by: "California Building Standards Commission, from the International Building Code" },
100
+ { ...federal("epa-asbestos-family", "U.S. Environmental Protection Agency", "Protect Your Family from Exposures to Asbestos", "https://www.epa.gov/asbestos/protect-your-family-exposures-asbestos"), checked: "2026-11-22" },
101
+ { ...federal("osha-asbestos", "OSHA, U.S. Department of Labor, in the eCFR", "29 CFR 1926.1101, Asbestos", "https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-Z/section-1926.1101"), checked: "2026-11-22" },
102
+ { ...federal("epa-lead-rrp", "U.S. Environmental Protection Agency", "Lead Renovation, Repair and Painting Program", "https://www.epa.gov/lead/lead-renovation-repair-and-painting-program"), checked: "2026-11-22" },
103
+ { ...federal("niosh-ffr", "CDC NIOSH", "Filtering Facepiece Respirators", "https://www.cdc.gov/niosh/ppe/respirators/ffr.html"), checked: "2026-11-22" },
104
+ { ...federal("usfa-smoke-alarms", "U.S. Fire Administration", "Smoke Alarms", "https://www.usfa.fema.gov/prevention/home-fires/prepare-for-fire/smoke-alarms/"), checked: "2026-11-22" },
105
+ { id: "twdb-roof-runoff", title: "Rainwater Volumes from Roof Runoff", url: "https://www.twdb.texas.gov/innovativewater/rainwater/roofrunoff.asp", license: "all-rights-reserved", checked: "2026-11-22", by: "Texas Water Development Board" },
81
106
  // The 72 hours guidance of SPEK, the Finnish National Rescue Association, with the Finnish government. The pages give no license.
82
107
  // Thus each step is a summary with a citation, not a quote.
83
108
  { id: "fi-72h-shelter", title: "Sheltering indoors", url: "https://72tuntia.fi/en/sheltering-indoors/", license: "all-rights-reserved", checked: "2026-11-22", by: "SPEK, 72 hours" },
@@ -183,5 +183,280 @@ const FIRST_72H: readonly CitedUnit[] = [
183
183
  },
184
184
  ];
185
185
 
186
+ /** The units of the tab stay: the failures of the building, water and waste in the home, doors, windows, walls and locks. */
187
+ const STAY: readonly CitedUnit[] = [
188
+ {
189
+ id: "tab.stay.building.elevator-stuck",
190
+ use: "summary",
191
+ text: "In a stopped elevator, ring the alarm and wait for help. Do not pry the doors open. Do not climb out without the help of the building management or emergency responders.",
192
+ source: "nyc-elevator",
193
+ },
194
+ {
195
+ id: "tab.stay.building.fire-stairs",
196
+ use: "summary",
197
+ text: "In a fire, do not use an elevator to go out. Always use the stairs.",
198
+ source: "usfa-apartment",
199
+ },
200
+ {
201
+ id: "tab.stay.building.heater-volume",
202
+ use: "fact",
203
+ text: "The tank of a water heater can give 30 to 80 gallons of water. A tankless heater gives none. Treat or filter this water before you drink it.",
204
+ source: "rwpc-water-heater",
205
+ },
206
+ {
207
+ id: "tab.stay.building.heater-power",
208
+ use: "summary",
209
+ text: "Before you take water from a water heater, close the main water valve of the home. Then turn off the power of the heater. For an electric heater, turn off its breaker. For a gas heater, turn the knob to pilot, not to off.",
210
+ source: "rwpc-water-heater",
211
+ },
212
+ {
213
+ id: "tab.stay.building.heater-air",
214
+ use: "summary",
215
+ text: "Next, close the water supply valve on the top of the heater. Then open a hot tap or the relief valve to let air in.",
216
+ source: "rwpc-water-heater",
217
+ },
218
+ {
219
+ id: "tab.stay.building.heater-drain",
220
+ use: "summary",
221
+ text: "Put a clean container under the drain valve at the bottom of the heater, and open the valve. The water can be very hot.",
222
+ source: "rwpc-water-heater",
223
+ },
224
+ {
225
+ id: "tab.stay.building.heater-refill",
226
+ use: "summary",
227
+ text: "Fill the tank of the water heater again before you turn the gas or the electricity back on.",
228
+ source: "fema-477",
229
+ },
230
+ {
231
+ id: "tab.stay.home-water.toilet-kit",
232
+ use: "summary",
233
+ text: "A bucket of 5 gallons can be a toilet. Add a toilet seat, and line it with a plastic bag inside a kitchen garbage bag. Put cat litter, peat moss or a disinfectant in the bag to absorb liquid and limit the odor.",
234
+ source: "ncdhhs-toilet",
235
+ },
236
+ {
237
+ id: "tab.stay.home-water.toilet-bags",
238
+ use: "summary",
239
+ text: "Keep the used toilet bags in a garbage can, away from children and animals.",
240
+ source: "ncdhhs-toilet",
241
+ },
242
+ {
243
+ id: "tab.stay.home-water.toilet-packet",
244
+ use: "summary",
245
+ text: "A packet latrine is a single-use bag that decays in the soil. Bury the used bags, or take them to a correct place for waste.",
246
+ source: "cdc-sanitation-emergency",
247
+ },
248
+ {
249
+ id: "tab.stay.door.egress",
250
+ use: "summary",
251
+ text: "An exit door must open from the inside with no key, no tool and no special knowledge or effort. A deadbolt or a chain on a home door must also open from the inside with no key or tool.",
252
+ source: "icc-ibc-door-operations",
253
+ locator: "Sections 1010.2 and 1010.2.4",
254
+ },
255
+ {
256
+ id: "tab.stay.door.fire-label",
257
+ use: "fact",
258
+ text: "A fire door assembly has a label on the door or on its frame.",
259
+ source: "cbc-716",
260
+ locator: "Section 716.2.9",
261
+ },
262
+ {
263
+ id: "tab.stay.door.fire-close",
264
+ use: "summary",
265
+ text: "A fire door must latch, and it must close by itself or automatically.",
266
+ source: "cbc-716",
267
+ locator: "Section 716.2.6",
268
+ },
269
+ {
270
+ id: "tab.stay.door.deadbolt",
271
+ use: "summary",
272
+ text: "Put a deadbolt of Grade 1 or Grade 2 on each outer door. A deadbolt usually locks with a key outside and a thumb turn inside.",
273
+ source: "kcso-door-locks",
274
+ },
275
+ {
276
+ id: "tab.stay.door.grade-1",
277
+ use: "fact",
278
+ text: "A deadbolt of Grade 1 must withstand 250,000 cycles and 10 strikes on the door with a hammer.",
279
+ source: "schlage-deadbolts",
280
+ },
281
+ {
282
+ id: "tab.stay.door.bolt-throw",
283
+ use: "fact",
284
+ text: "The bolt of a deadbolt goes out at least 1 inch.",
285
+ source: "kcso-door-locks",
286
+ },
287
+ {
288
+ id: "tab.stay.door.strike",
289
+ use: "summary",
290
+ text: "Use a strike plate for heavy use, with 4 screws. The screws are at least 3 inches long and go into the wood door frame.",
291
+ source: "kcso-door-locks",
292
+ },
293
+ {
294
+ id: "tab.stay.door.hinges",
295
+ use: "summary",
296
+ text: "Put the hinges on the inside, or use hinge pins that cannot come out.",
297
+ source: "kcso-door-locks",
298
+ },
299
+ {
300
+ id: "tab.stay.door.viewer",
301
+ use: "fact",
302
+ text: "A wide-angle door viewer is safer than a door chain to identify a visitor.",
303
+ source: "kcso-door-locks",
304
+ },
305
+ {
306
+ id: "tab.stay.door.fire-viewer",
307
+ use: "fact",
308
+ text: "In a fire door of a corridor, the hole for a door viewer is 1 inch or less.",
309
+ source: "cbc-716",
310
+ locator: "Section 716.2.2.1, Exception 1",
311
+ },
312
+ {
313
+ id: "tab.stay.windows.plywood",
314
+ use: "summary",
315
+ text: "Most building codes permit plywood of 1/2 inch for window covers. Mark each cover with the name of its window.",
316
+ source: "fl-diy-shutters",
317
+ },
318
+ {
319
+ id: "tab.stay.windows.anchors",
320
+ use: "summary",
321
+ text: "Attach each cover with fasteners that go 2 inches into the wood frame. Spring clips, barrel bolts and wedges are not a tested attachment. They can fail.",
322
+ source: "fl-diy-shutters",
323
+ },
324
+ {
325
+ id: "tab.stay.windows.escape-covers",
326
+ use: "summary",
327
+ text: "The escape opening of a sleeping room opens from the inside with no key, tool or special knowledge. Bars, grilles or covers on it must release from the inside with no key, no tool and no extra force.",
328
+ source: "icc-irc-r310",
329
+ locator: "Sections R310.1.1 and R310.4",
330
+ },
331
+ {
332
+ id: "tab.stay.windows.film",
333
+ use: "summary",
334
+ text: "Safety and security film holds broken glass in place and delays an entry, mostly with an attachment system. It does not stop bullets.",
335
+ source: "iwfa-safety-film",
336
+ },
337
+ {
338
+ id: "tab.stay.walls.fire-partition",
339
+ use: "fact",
340
+ text: "The walls between dwelling units are fire partitions. Their rating is at least 1 hour. In some types of buildings with sprinklers, it can be 1/2 hour.",
341
+ source: "cbc-708",
342
+ locator: "Sections 708.1 and 708.3",
343
+ },
344
+ {
345
+ id: "tab.stay.walls.lead-paint",
346
+ use: "fact",
347
+ text: "Approximately three-quarters of the US homes from before 1978 still have some lead-based paint.",
348
+ source: "epa-lead-rrp",
349
+ },
350
+ {
351
+ id: "tab.stay.walls.asbestos-presume",
352
+ use: "summary",
353
+ text: "The OSHA asbestos rule is for workers. In buildings from 1980 or before, it treats pipe and boiler insulation as asbestos. It also treats sprayed or troweled coats, and asphalt and vinyl floors, as asbestos.",
354
+ source: "osha-asbestos",
355
+ locator: "Paragraphs (b) and (k)(1)",
356
+ },
357
+ {
358
+ id: "tab.stay.walls.asbestos-look",
359
+ use: "summary",
360
+ text: "You cannot see asbestos in a material, unless the material has a label. Leave material with asbestos alone when it is not damaged.",
361
+ source: "epa-asbestos-family",
362
+ },
363
+ {
364
+ id: "tab.stay.walls.asbestos-dust",
365
+ use: "summary",
366
+ text: "Do not saw, sand, scrape or drill holes in material with asbestos. Do not dust, sweep or vacuum debris that can hold asbestos.",
367
+ source: "epa-asbestos-family",
368
+ },
369
+ {
370
+ id: "tab.stay.walls.asbestos-pro",
371
+ use: "summary",
372
+ text: "The removal of asbestos is complex. Only a trained and accredited asbestos professional does it.",
373
+ source: "epa-asbestos-family",
374
+ },
375
+ {
376
+ id: "tab.stay.walls.asbestos-wet",
377
+ use: "summary",
378
+ text: "In Class II removal work, the OSHA rule asks to remove the material whole, with no cutting. Wet it with water and a wetting agent before and during the removal.",
379
+ source: "osha-asbestos",
380
+ locator: "Paragraph (g)(8)(v)",
381
+ },
382
+ {
383
+ id: "tab.stay.walls.asbestos-mask",
384
+ use: "summary",
385
+ text: "For asbestos work, the OSHA rule asks for respirators with HEPA filters. It does not permit filtering facepiece respirators, disposable respirators or dust masks.",
386
+ source: "osha-asbestos",
387
+ locator: "Paragraph (h)(3), and Appendix H, part III",
388
+ },
389
+ {
390
+ id: "tab.stay.walls.p100",
391
+ use: "fact",
392
+ text: "A P100 filter stops at least 99.97 % of the particles in the air. A filtering facepiece respirator needs a fit test.",
393
+ source: "niosh-ffr",
394
+ },
395
+ {
396
+ id: "tab.stay.walls.asbestos-papr",
397
+ use: "summary",
398
+ text: "The removal of pipe insulation or sprayed coats is Class I work. For it, the OSHA rule asks for a powered air-purifying respirator or a supplied-air respirator.",
399
+ source: "osha-asbestos",
400
+ locator: "Paragraphs (b) and (h)(3)(iv)",
401
+ },
402
+ {
403
+ id: "tab.stay.e-locks.magnetic-fail-safe",
404
+ use: "fact",
405
+ text: "An electromagnetic lock is only available fail safe. When the power stops, it unlocks.",
406
+ source: "allegion-fail-safe",
407
+ },
408
+ {
409
+ id: "tab.stay.e-locks.power-loss",
410
+ use: "fact",
411
+ text: "On an exit door with an electric lock, a loss of power unlocks the door.",
412
+ source: "icc-ibc-electric-locks",
413
+ locator: "Sections 1010.2.11 and 1010.2.12",
414
+ },
415
+ {
416
+ id: "tab.stay.e-locks.strike-secure",
417
+ use: "summary",
418
+ text: "An electric strike on a fire door must be fail secure. With no power, a fail-secure strike keeps the door locked from the outside.",
419
+ source: "allegion-fail-safe",
420
+ },
421
+ {
422
+ id: "tab.stay.e-locks.strike-exit",
423
+ use: "summary",
424
+ text: "With a fail-safe or a fail-secure electric strike, you can go out. Turn the lever, or push the touchpad of the exit device.",
425
+ source: "allegion-fail-safe",
426
+ },
427
+ {
428
+ id: "tab.stay.e-locks.push-to-exit",
429
+ use: "fact",
430
+ text: "A door with a sensor release also has a manual unlock device within 5 feet. Its sign reads PUSH TO EXIT.",
431
+ source: "icc-ibc-electric-locks",
432
+ locator: "Section 1010.2.12",
433
+ },
434
+ {
435
+ id: "tab.stay.e-locks.hardware-release",
436
+ use: "fact",
437
+ text: "With a door hardware release, the handle or the bar cuts the power and unlocks the door at once.",
438
+ source: "icc-ibc-electric-locks",
439
+ locator: "Section 1010.2.11",
440
+ },
441
+ {
442
+ id: "tab.stay.list.smoke-alarms",
443
+ use: "summary",
444
+ text: "Put smoke alarms inside and outside each bedroom and sleeping area, and on each level of the home.",
445
+ source: "usfa-smoke-alarms",
446
+ },
447
+ {
448
+ id: "tab.stay.list.extinguisher-abc",
449
+ use: "fact",
450
+ text: "A multipurpose extinguisher with the label A-B-C can be used on most types of home fires.",
451
+ source: "usfa-extinguishers",
452
+ },
453
+ {
454
+ id: "tab.stay.base.rain-yield",
455
+ use: "fact",
456
+ text: "At approximately 80 percent collection, 1 inch of rain on 2,000 square feet gives approximately 1,000 gallons. That is approximately 50 gallons from 100 square feet.",
457
+ source: "twdb-roof-runoff",
458
+ },
459
+ ];
460
+
186
461
  /** The cited units of the tabs of the binder. The units of the other tabs come in later changes. */
187
- export const TAB_UNITS: readonly CitedUnit[] = [...GO, ...FIRST_72H];
462
+ export const TAB_UNITS: readonly CitedUnit[] = [...GO, ...FIRST_72H, ...STAY];