@hydranium/protocol 1.0.0-next.260 → 1.0.0-next.262
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
|
@@ -108,8 +108,8 @@ export interface MessageRelay extends Disposable {
|
|
|
108
108
|
* buffers; the hand-off then swaps listeners and replays within one turn of the
|
|
109
109
|
* event loop, which is what makes it impossible for a message to be both
|
|
110
110
|
* buffered and forwarded, or to arrive between the two. Replay is FIFO because
|
|
111
|
-
* order is load-bearing —
|
|
112
|
-
* `openModelDocument` would
|
|
111
|
+
* order is load-bearing — an `updateModelDocument` that overtook its own
|
|
112
|
+
* `openModelDocument` would be refused with `DocumentNotOpenError`.
|
|
113
113
|
* `@hydranium/client-theia`'s `AbstractSocketForwardingConnectionHandler` carries the
|
|
114
114
|
* same fix for the Theia channel transport.
|
|
115
115
|
*/
|
|
@@ -55,8 +55,8 @@ exports.RELAY_REPLAY_FAILED = (0, primitives_1.defineMessage)('hydranium/protoco
|
|
|
55
55
|
* buffers; the hand-off then swaps listeners and replays within one turn of the
|
|
56
56
|
* event loop, which is what makes it impossible for a message to be both
|
|
57
57
|
* buffered and forwarded, or to arrive between the two. Replay is FIFO because
|
|
58
|
-
* order is load-bearing —
|
|
59
|
-
* `openModelDocument` would
|
|
58
|
+
* order is load-bearing — an `updateModelDocument` that overtook its own
|
|
59
|
+
* `openModelDocument` would be refused with `DocumentNotOpenError`.
|
|
60
60
|
* `@hydranium/client-theia`'s `AbstractSocketForwardingConnectionHandler` carries the
|
|
61
61
|
* same fix for the Theia channel transport.
|
|
62
62
|
*/
|
package/package.json
CHANGED
|
@@ -130,8 +130,8 @@ export interface MessageRelay extends Disposable {
|
|
|
130
130
|
* buffers; the hand-off then swaps listeners and replays within one turn of the
|
|
131
131
|
* event loop, which is what makes it impossible for a message to be both
|
|
132
132
|
* buffered and forwarded, or to arrive between the two. Replay is FIFO because
|
|
133
|
-
* order is load-bearing —
|
|
134
|
-
* `openModelDocument` would
|
|
133
|
+
* order is load-bearing — an `updateModelDocument` that overtook its own
|
|
134
|
+
* `openModelDocument` would be refused with `DocumentNotOpenError`.
|
|
135
135
|
* `@hydranium/client-theia`'s `AbstractSocketForwardingConnectionHandler` carries the
|
|
136
136
|
* same fix for the Theia channel transport.
|
|
137
137
|
*/
|