@gridsuite/commons-ui 0.63.2 → 0.63.3

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
@@ -23,6 +23,10 @@ const EXPERT_FILTER_EQUIPMENTS = {
23
23
  id: "TWO_WINDINGS_TRANSFORMER",
24
24
  label: "TwoWindingsTransformers"
25
25
  },
26
+ THREE_WINDINGS_TRANSFORMER: {
27
+ id: "THREE_WINDINGS_TRANSFORMER",
28
+ label: "ThreeWindingsTransformers"
29
+ },
26
30
  GENERATOR: {
27
31
  id: "GENERATOR",
28
32
  label: "Generators"
@@ -46,6 +50,10 @@ const EXPERT_FILTER_EQUIPMENTS = {
46
50
  HVDC_LINE: {
47
51
  id: "HVDC_LINE",
48
52
  label: "Hvdc"
53
+ },
54
+ DANGLING_LINE: {
55
+ id: "DANGLING_LINE",
56
+ label: "DanglingLines"
49
57
  }
50
58
  };
51
59
  const ENERGY_SOURCE_OPTIONS = [
@@ -254,6 +262,24 @@ const FIELDS_OPTIONS = {
254
262
  dataType: DataType.NUMBER,
255
263
  inputType: "number"
256
264
  },
265
+ RATED_S1: {
266
+ name: FieldType.RATED_S1,
267
+ label: "ratedS1",
268
+ dataType: DataType.NUMBER,
269
+ inputType: "number"
270
+ },
271
+ RATED_S2: {
272
+ name: FieldType.RATED_S2,
273
+ label: "ratedS2",
274
+ dataType: DataType.NUMBER,
275
+ inputType: "number"
276
+ },
277
+ RATED_S3: {
278
+ name: FieldType.RATED_S3,
279
+ label: "ratedS3",
280
+ dataType: DataType.NUMBER,
281
+ inputType: "number"
282
+ },
257
283
  MARGINAL_COST: {
258
284
  name: FieldType.MARGINAL_COST,
259
285
  label: "marginalCost",
@@ -377,6 +403,13 @@ const FIELDS_OPTIONS = {
377
403
  defaultValue: false,
378
404
  valueEditorType: "switch"
379
405
  },
406
+ CONNECTED_3: {
407
+ name: FieldType.CONNECTED_3,
408
+ label: "terminal3Connected",
409
+ dataType: DataType.BOOLEAN,
410
+ defaultValue: false,
411
+ valueEditorType: "switch"
412
+ },
380
413
  VOLTAGE_LEVEL_ID_1: {
381
414
  name: FieldType.VOLTAGE_LEVEL_ID_1,
382
415
  label: "voltageLevelId1",
@@ -387,6 +420,11 @@ const FIELDS_OPTIONS = {
387
420
  label: "voltageLevelId2",
388
421
  dataType: DataType.STRING
389
422
  },
423
+ VOLTAGE_LEVEL_ID_3: {
424
+ name: FieldType.VOLTAGE_LEVEL_ID_3,
425
+ label: "voltageLevelId3",
426
+ dataType: DataType.STRING
427
+ },
390
428
  NOMINAL_VOLTAGE_1: {
391
429
  name: FieldType.NOMINAL_VOLTAGE_1,
392
430
  label: "nominalVoltage1KV",
@@ -399,6 +437,18 @@ const FIELDS_OPTIONS = {
399
437
  dataType: DataType.NUMBER,
400
438
  inputType: "number"
401
439
  },
440
+ NOMINAL_VOLTAGE_3: {
441
+ name: FieldType.NOMINAL_VOLTAGE_3,
442
+ label: "nominalVoltage3KV",
443
+ dataType: DataType.NUMBER,
444
+ inputType: "number"
445
+ },
446
+ RATED_VOLTAGE_0: {
447
+ name: FieldType.RATED_VOLTAGE_0,
448
+ label: "ratedVoltage0KV",
449
+ dataType: DataType.NUMBER,
450
+ inputType: "number"
451
+ },
402
452
  RATED_VOLTAGE_1: {
403
453
  name: FieldType.RATED_VOLTAGE_1,
404
454
  label: "ratedVoltage1KV",
@@ -411,6 +461,12 @@ const FIELDS_OPTIONS = {
411
461
  dataType: DataType.NUMBER,
412
462
  inputType: "number"
413
463
  },
464
+ RATED_VOLTAGE_3: {
465
+ name: FieldType.RATED_VOLTAGE_3,
466
+ label: "ratedVoltage3KV",
467
+ dataType: DataType.NUMBER,
468
+ inputType: "number"
469
+ },
414
470
  COUNTRY_1: {
415
471
  name: FieldType.COUNTRY_1,
416
472
  label: "country1",
@@ -431,12 +487,48 @@ const FIELDS_OPTIONS = {
431
487
  dataType: DataType.NUMBER,
432
488
  inputType: "number"
433
489
  },
490
+ SERIE_RESISTANCE_1: {
491
+ name: FieldType.SERIE_RESISTANCE_1,
492
+ label: "seriesResistance1",
493
+ dataType: DataType.NUMBER,
494
+ inputType: "number"
495
+ },
496
+ SERIE_RESISTANCE_2: {
497
+ name: FieldType.SERIE_RESISTANCE_2,
498
+ label: "seriesResistance2",
499
+ dataType: DataType.NUMBER,
500
+ inputType: "number"
501
+ },
502
+ SERIE_RESISTANCE_3: {
503
+ name: FieldType.SERIE_RESISTANCE_3,
504
+ label: "seriesResistance3",
505
+ dataType: DataType.NUMBER,
506
+ inputType: "number"
507
+ },
434
508
  SERIE_REACTANCE: {
435
509
  name: FieldType.SERIE_REACTANCE,
436
510
  label: "seriesReactance",
437
511
  dataType: DataType.NUMBER,
438
512
  inputType: "number"
439
513
  },
514
+ SERIE_REACTANCE_1: {
515
+ name: FieldType.SERIE_REACTANCE_1,
516
+ label: "seriesReactance1",
517
+ dataType: DataType.NUMBER,
518
+ inputType: "number"
519
+ },
520
+ SERIE_REACTANCE_2: {
521
+ name: FieldType.SERIE_REACTANCE_2,
522
+ label: "seriesReactance2",
523
+ dataType: DataType.NUMBER,
524
+ inputType: "number"
525
+ },
526
+ SERIE_REACTANCE_3: {
527
+ name: FieldType.SERIE_REACTANCE_3,
528
+ label: "seriesReactance3",
529
+ dataType: DataType.NUMBER,
530
+ inputType: "number"
531
+ },
440
532
  SHUNT_CONDUCTANCE_1: {
441
533
  name: FieldType.SHUNT_CONDUCTANCE_1,
442
534
  label: "shuntConductance1",
@@ -467,12 +559,48 @@ const FIELDS_OPTIONS = {
467
559
  dataType: DataType.NUMBER,
468
560
  inputType: "number"
469
561
  },
562
+ MAGNETIZING_CONDUCTANCE_1: {
563
+ name: FieldType.MAGNETIZING_CONDUCTANCE_1,
564
+ label: "magnetizingConductance1",
565
+ dataType: DataType.NUMBER,
566
+ inputType: "number"
567
+ },
568
+ MAGNETIZING_CONDUCTANCE_2: {
569
+ name: FieldType.MAGNETIZING_CONDUCTANCE_2,
570
+ label: "magnetizingConductance2",
571
+ dataType: DataType.NUMBER,
572
+ inputType: "number"
573
+ },
574
+ MAGNETIZING_CONDUCTANCE_3: {
575
+ name: FieldType.MAGNETIZING_CONDUCTANCE_3,
576
+ label: "magnetizingConductance3",
577
+ dataType: DataType.NUMBER,
578
+ inputType: "number"
579
+ },
470
580
  MAGNETIZING_SUSCEPTANCE: {
471
581
  name: FieldType.MAGNETIZING_SUSCEPTANCE,
472
582
  label: "magnetizingSusceptance",
473
583
  dataType: DataType.NUMBER,
474
584
  inputType: "number"
475
585
  },
586
+ MAGNETIZING_SUSCEPTANCE_1: {
587
+ name: FieldType.MAGNETIZING_SUSCEPTANCE_1,
588
+ label: "magnetizingSusceptance1",
589
+ dataType: DataType.NUMBER,
590
+ inputType: "number"
591
+ },
592
+ MAGNETIZING_SUSCEPTANCE_2: {
593
+ name: FieldType.MAGNETIZING_SUSCEPTANCE_2,
594
+ label: "magnetizingSusceptance2",
595
+ dataType: DataType.NUMBER,
596
+ inputType: "number"
597
+ },
598
+ MAGNETIZING_SUSCEPTANCE_3: {
599
+ name: FieldType.MAGNETIZING_SUSCEPTANCE_3,
600
+ label: "magnetizingSusceptance3",
601
+ dataType: DataType.NUMBER,
602
+ inputType: "number"
603
+ },
476
604
  LOAD_TYPE: {
477
605
  name: FieldType.LOAD_TYPE,
478
606
  label: "loadType",
@@ -488,6 +616,27 @@ const FIELDS_OPTIONS = {
488
616
  defaultValue: false,
489
617
  valueEditorType: "switch"
490
618
  },
619
+ HAS_RATIO_TAP_CHANGER_1: {
620
+ name: FieldType.HAS_RATIO_TAP_CHANGER_1,
621
+ label: "hasRatioTapChanger1",
622
+ dataType: DataType.BOOLEAN,
623
+ defaultValue: false,
624
+ valueEditorType: "switch"
625
+ },
626
+ HAS_RATIO_TAP_CHANGER_2: {
627
+ name: FieldType.HAS_RATIO_TAP_CHANGER_2,
628
+ label: "hasRatioTapChanger2",
629
+ dataType: DataType.BOOLEAN,
630
+ defaultValue: false,
631
+ valueEditorType: "switch"
632
+ },
633
+ HAS_RATIO_TAP_CHANGER_3: {
634
+ name: FieldType.HAS_RATIO_TAP_CHANGER_3,
635
+ label: "hasRatioTapChanger3",
636
+ dataType: DataType.BOOLEAN,
637
+ defaultValue: false,
638
+ valueEditorType: "switch"
639
+ },
491
640
  LOAD_TAP_CHANGING_CAPABILITIES: {
492
641
  name: FieldType.LOAD_TAP_CHANGING_CAPABILITIES,
493
642
  label: "loadTapChangingCapabilities",
@@ -495,6 +644,27 @@ const FIELDS_OPTIONS = {
495
644
  defaultValue: false,
496
645
  valueEditorType: "switch"
497
646
  },
647
+ LOAD_TAP_CHANGING_CAPABILITIES_1: {
648
+ name: FieldType.LOAD_TAP_CHANGING_CAPABILITIES_1,
649
+ label: "loadTapChangingCapabilities1",
650
+ dataType: DataType.BOOLEAN,
651
+ defaultValue: false,
652
+ valueEditorType: "switch"
653
+ },
654
+ LOAD_TAP_CHANGING_CAPABILITIES_2: {
655
+ name: FieldType.LOAD_TAP_CHANGING_CAPABILITIES_2,
656
+ label: "loadTapChangingCapabilities2",
657
+ dataType: DataType.BOOLEAN,
658
+ defaultValue: false,
659
+ valueEditorType: "switch"
660
+ },
661
+ LOAD_TAP_CHANGING_CAPABILITIES_3: {
662
+ name: FieldType.LOAD_TAP_CHANGING_CAPABILITIES_3,
663
+ label: "loadTapChangingCapabilities3",
664
+ dataType: DataType.BOOLEAN,
665
+ defaultValue: false,
666
+ valueEditorType: "switch"
667
+ },
498
668
  RATIO_REGULATION_MODE: {
499
669
  name: FieldType.RATIO_REGULATION_MODE,
500
670
  label: "ratioRegulationMode",
@@ -503,12 +673,54 @@ const FIELDS_OPTIONS = {
503
673
  valueEditorType: "select",
504
674
  defaultValue: "VOLTAGE_REGULATION"
505
675
  },
676
+ RATIO_REGULATION_MODE_1: {
677
+ name: FieldType.RATIO_REGULATION_MODE_1,
678
+ label: "ratioRegulationMode1",
679
+ dataType: DataType.ENUM,
680
+ values: RATIO_REGULATION_MODE_OPTIONS,
681
+ valueEditorType: "select",
682
+ defaultValue: "VOLTAGE_REGULATION"
683
+ },
684
+ RATIO_REGULATION_MODE_2: {
685
+ name: FieldType.RATIO_REGULATION_MODE_2,
686
+ label: "ratioRegulationMode2",
687
+ dataType: DataType.ENUM,
688
+ values: RATIO_REGULATION_MODE_OPTIONS,
689
+ valueEditorType: "select",
690
+ defaultValue: "VOLTAGE_REGULATION"
691
+ },
692
+ RATIO_REGULATION_MODE_3: {
693
+ name: FieldType.RATIO_REGULATION_MODE_3,
694
+ label: "ratioRegulationMode3",
695
+ dataType: DataType.ENUM,
696
+ values: RATIO_REGULATION_MODE_OPTIONS,
697
+ valueEditorType: "select",
698
+ defaultValue: "VOLTAGE_REGULATION"
699
+ },
506
700
  RATIO_TARGET_V: {
507
701
  name: FieldType.RATIO_TARGET_V,
508
702
  label: "ratioTargetV",
509
703
  dataType: DataType.NUMBER,
510
704
  inputType: "number"
511
705
  },
706
+ RATIO_TARGET_V1: {
707
+ name: FieldType.RATIO_TARGET_V1,
708
+ label: "ratioTargetV1",
709
+ dataType: DataType.NUMBER,
710
+ inputType: "number"
711
+ },
712
+ RATIO_TARGET_V2: {
713
+ name: FieldType.RATIO_TARGET_V2,
714
+ label: "ratioTargetV2",
715
+ dataType: DataType.NUMBER,
716
+ inputType: "number"
717
+ },
718
+ RATIO_TARGET_V3: {
719
+ name: FieldType.RATIO_TARGET_V3,
720
+ label: "ratioTargetV3",
721
+ dataType: DataType.NUMBER,
722
+ inputType: "number"
723
+ },
512
724
  HAS_PHASE_TAP_CHANGER: {
513
725
  name: FieldType.HAS_PHASE_TAP_CHANGER,
514
726
  label: "hasPhaseTapChanger",
@@ -516,6 +728,27 @@ const FIELDS_OPTIONS = {
516
728
  defaultValue: false,
517
729
  valueEditorType: "switch"
518
730
  },
731
+ HAS_PHASE_TAP_CHANGER_1: {
732
+ name: FieldType.HAS_PHASE_TAP_CHANGER_1,
733
+ label: "hasPhaseTapChanger1",
734
+ dataType: DataType.BOOLEAN,
735
+ defaultValue: false,
736
+ valueEditorType: "switch"
737
+ },
738
+ HAS_PHASE_TAP_CHANGER_2: {
739
+ name: FieldType.HAS_PHASE_TAP_CHANGER_2,
740
+ label: "hasPhaseTapChanger2",
741
+ dataType: DataType.BOOLEAN,
742
+ defaultValue: false,
743
+ valueEditorType: "switch"
744
+ },
745
+ HAS_PHASE_TAP_CHANGER_3: {
746
+ name: FieldType.HAS_PHASE_TAP_CHANGER_3,
747
+ label: "hasPhaseTapChanger3",
748
+ dataType: DataType.BOOLEAN,
749
+ defaultValue: false,
750
+ valueEditorType: "switch"
751
+ },
519
752
  PHASE_REGULATION_MODE: {
520
753
  name: FieldType.PHASE_REGULATION_MODE,
521
754
  label: "phaseRegulationMode",
@@ -524,12 +757,54 @@ const FIELDS_OPTIONS = {
524
757
  valueEditorType: "select",
525
758
  defaultValue: "CURRENT_LIMITER"
526
759
  },
760
+ PHASE_REGULATION_MODE_1: {
761
+ name: FieldType.PHASE_REGULATION_MODE_1,
762
+ label: "phaseRegulationMode1",
763
+ dataType: DataType.ENUM,
764
+ values: PHASE_REGULATION_MODE_OPTIONS,
765
+ valueEditorType: "select",
766
+ defaultValue: "CURRENT_LIMITER"
767
+ },
768
+ PHASE_REGULATION_MODE_2: {
769
+ name: FieldType.PHASE_REGULATION_MODE_2,
770
+ label: "phaseRegulationMode2",
771
+ dataType: DataType.ENUM,
772
+ values: PHASE_REGULATION_MODE_OPTIONS,
773
+ valueEditorType: "select",
774
+ defaultValue: "CURRENT_LIMITER"
775
+ },
776
+ PHASE_REGULATION_MODE_3: {
777
+ name: FieldType.PHASE_REGULATION_MODE_3,
778
+ label: "phaseRegulationMode3",
779
+ dataType: DataType.ENUM,
780
+ values: PHASE_REGULATION_MODE_OPTIONS,
781
+ valueEditorType: "select",
782
+ defaultValue: "CURRENT_LIMITER"
783
+ },
527
784
  PHASE_REGULATION_VALUE: {
528
785
  name: FieldType.PHASE_REGULATION_VALUE,
529
786
  label: "phaseRegulationValue",
530
787
  dataType: DataType.NUMBER,
531
788
  inputType: "number"
532
789
  },
790
+ PHASE_REGULATION_VALUE_1: {
791
+ name: FieldType.PHASE_REGULATION_VALUE_1,
792
+ label: "phaseRegulationValue1",
793
+ dataType: DataType.NUMBER,
794
+ inputType: "number"
795
+ },
796
+ PHASE_REGULATION_VALUE_2: {
797
+ name: FieldType.PHASE_REGULATION_VALUE_2,
798
+ label: "phaseRegulationValue2",
799
+ dataType: DataType.NUMBER,
800
+ inputType: "number"
801
+ },
802
+ PHASE_REGULATION_VALUE_3: {
803
+ name: FieldType.PHASE_REGULATION_VALUE_3,
804
+ label: "phaseRegulationValue3",
805
+ dataType: DataType.NUMBER,
806
+ inputType: "number"
807
+ },
533
808
  PROPERTY: {
534
809
  name: FieldType.PROPERTY,
535
810
  label: "property",
@@ -558,6 +833,13 @@ const FIELDS_OPTIONS = {
558
833
  valueEditorType: "select",
559
834
  defaultValue: ""
560
835
  },
836
+ SUBSTATION_PROPERTY_3: {
837
+ name: FieldType.SUBSTATION_PROPERTY_3,
838
+ label: "substationProperty3",
839
+ dataType: DataType.PROPERTY,
840
+ valueEditorType: "select",
841
+ defaultValue: ""
842
+ },
561
843
  VOLTAGE_LEVEL_PROPERTY: {
562
844
  name: FieldType.VOLTAGE_LEVEL_PROPERTY,
563
845
  label: "voltageLevelProperty",
@@ -579,6 +861,13 @@ const FIELDS_OPTIONS = {
579
861
  valueEditorType: "select",
580
862
  defaultValue: ""
581
863
  },
864
+ VOLTAGE_LEVEL_PROPERTY_3: {
865
+ name: FieldType.VOLTAGE_LEVEL_PROPERTY_3,
866
+ label: "voltageLevelProperty3",
867
+ dataType: DataType.PROPERTY,
868
+ valueEditorType: "select",
869
+ defaultValue: ""
870
+ },
582
871
  SVAR_REGULATION_MODE: {
583
872
  name: FieldType.SVAR_REGULATION_MODE,
584
873
  label: "regulationMode",
@@ -669,6 +958,25 @@ const FIELDS_OPTIONS = {
669
958
  dataType: DataType.NUMBER,
670
959
  inputType: "number"
671
960
  },
961
+ SHUNT_SUSCEPTANCE: {
962
+ name: FieldType.SHUNT_SUSCEPTANCE,
963
+ label: "shuntSusceptance",
964
+ dataType: DataType.NUMBER,
965
+ inputType: "number"
966
+ },
967
+ SHUNT_CONDUCTANCE: {
968
+ name: FieldType.SHUNT_CONDUCTANCE,
969
+ label: "shuntConductance",
970
+ dataType: DataType.NUMBER,
971
+ inputType: "number"
972
+ },
973
+ PAIRED: {
974
+ name: FieldType.PAIRED,
975
+ label: "paired",
976
+ dataType: DataType.BOOLEAN,
977
+ defaultValue: false,
978
+ valueEditorType: "switch"
979
+ },
672
980
  CONVERTER_STATION_ID_1: {
673
981
  name: FieldType.CONVERTER_STATION_ID_1,
674
982
  label: "converterStationId1",
@@ -776,6 +1084,67 @@ const fields = {
776
1084
  FIELDS_OPTIONS.VOLTAGE_LEVEL_PROPERTY_1,
777
1085
  FIELDS_OPTIONS.VOLTAGE_LEVEL_PROPERTY_2
778
1086
  ],
1087
+ THREE_WINDINGS_TRANSFORMER: [
1088
+ FIELDS_OPTIONS.ID,
1089
+ FIELDS_OPTIONS.NAME,
1090
+ FIELDS_OPTIONS.COUNTRY,
1091
+ FIELDS_OPTIONS.VOLTAGE_LEVEL_ID_1,
1092
+ FIELDS_OPTIONS.VOLTAGE_LEVEL_ID_2,
1093
+ FIELDS_OPTIONS.VOLTAGE_LEVEL_ID_3,
1094
+ FIELDS_OPTIONS.NOMINAL_VOLTAGE_1,
1095
+ FIELDS_OPTIONS.NOMINAL_VOLTAGE_2,
1096
+ FIELDS_OPTIONS.NOMINAL_VOLTAGE_3,
1097
+ FIELDS_OPTIONS.CONNECTED_1,
1098
+ FIELDS_OPTIONS.CONNECTED_2,
1099
+ FIELDS_OPTIONS.CONNECTED_3,
1100
+ FIELDS_OPTIONS.RATED_VOLTAGE_0,
1101
+ FIELDS_OPTIONS.RATED_VOLTAGE_1,
1102
+ FIELDS_OPTIONS.RATED_VOLTAGE_2,
1103
+ FIELDS_OPTIONS.RATED_VOLTAGE_3,
1104
+ FIELDS_OPTIONS.RATED_S1,
1105
+ FIELDS_OPTIONS.RATED_S2,
1106
+ FIELDS_OPTIONS.RATED_S3,
1107
+ FIELDS_OPTIONS.SERIE_RESISTANCE_1,
1108
+ FIELDS_OPTIONS.SERIE_RESISTANCE_2,
1109
+ FIELDS_OPTIONS.SERIE_RESISTANCE_3,
1110
+ FIELDS_OPTIONS.SERIE_REACTANCE_1,
1111
+ FIELDS_OPTIONS.SERIE_REACTANCE_2,
1112
+ FIELDS_OPTIONS.SERIE_REACTANCE_3,
1113
+ FIELDS_OPTIONS.MAGNETIZING_CONDUCTANCE_1,
1114
+ FIELDS_OPTIONS.MAGNETIZING_CONDUCTANCE_2,
1115
+ FIELDS_OPTIONS.MAGNETIZING_CONDUCTANCE_3,
1116
+ FIELDS_OPTIONS.MAGNETIZING_SUSCEPTANCE_1,
1117
+ FIELDS_OPTIONS.MAGNETIZING_SUSCEPTANCE_2,
1118
+ FIELDS_OPTIONS.MAGNETIZING_SUSCEPTANCE_3,
1119
+ FIELDS_OPTIONS.HAS_RATIO_TAP_CHANGER_1,
1120
+ FIELDS_OPTIONS.HAS_RATIO_TAP_CHANGER_2,
1121
+ FIELDS_OPTIONS.HAS_RATIO_TAP_CHANGER_3,
1122
+ FIELDS_OPTIONS.LOAD_TAP_CHANGING_CAPABILITIES_1,
1123
+ FIELDS_OPTIONS.LOAD_TAP_CHANGING_CAPABILITIES_2,
1124
+ FIELDS_OPTIONS.LOAD_TAP_CHANGING_CAPABILITIES_3,
1125
+ FIELDS_OPTIONS.RATIO_TARGET_V1,
1126
+ FIELDS_OPTIONS.RATIO_TARGET_V2,
1127
+ FIELDS_OPTIONS.RATIO_TARGET_V3,
1128
+ FIELDS_OPTIONS.RATIO_REGULATION_MODE_1,
1129
+ FIELDS_OPTIONS.RATIO_REGULATION_MODE_2,
1130
+ FIELDS_OPTIONS.RATIO_REGULATION_MODE_3,
1131
+ FIELDS_OPTIONS.HAS_PHASE_TAP_CHANGER_1,
1132
+ FIELDS_OPTIONS.HAS_PHASE_TAP_CHANGER_2,
1133
+ FIELDS_OPTIONS.HAS_PHASE_TAP_CHANGER_3,
1134
+ FIELDS_OPTIONS.PHASE_REGULATION_VALUE_1,
1135
+ FIELDS_OPTIONS.PHASE_REGULATION_VALUE_2,
1136
+ FIELDS_OPTIONS.PHASE_REGULATION_VALUE_3,
1137
+ FIELDS_OPTIONS.PHASE_REGULATION_MODE_1,
1138
+ FIELDS_OPTIONS.PHASE_REGULATION_MODE_2,
1139
+ FIELDS_OPTIONS.PHASE_REGULATION_MODE_3,
1140
+ FIELDS_OPTIONS.PROPERTY,
1141
+ FIELDS_OPTIONS.SUBSTATION_PROPERTY_1,
1142
+ FIELDS_OPTIONS.SUBSTATION_PROPERTY_2,
1143
+ FIELDS_OPTIONS.SUBSTATION_PROPERTY_3,
1144
+ FIELDS_OPTIONS.VOLTAGE_LEVEL_PROPERTY_1,
1145
+ FIELDS_OPTIONS.VOLTAGE_LEVEL_PROPERTY_2,
1146
+ FIELDS_OPTIONS.VOLTAGE_LEVEL_PROPERTY_3
1147
+ ],
779
1148
  GENERATOR: [
780
1149
  FIELDS_OPTIONS.ID,
781
1150
  FIELDS_OPTIONS.NAME,
@@ -799,31 +1168,31 @@ const fields = {
799
1168
  FIELDS_OPTIONS.SUBSTATION_PROPERTY,
800
1169
  FIELDS_OPTIONS.VOLTAGE_LEVEL_PROPERTY
801
1170
  ],
802
- LOAD: [
1171
+ BATTERY: [
803
1172
  FIELDS_OPTIONS.ID,
804
1173
  FIELDS_OPTIONS.NAME,
805
- FIELDS_OPTIONS.LOAD_TYPE,
806
1174
  FIELDS_OPTIONS.COUNTRY,
807
1175
  FIELDS_OPTIONS.VOLTAGE_LEVEL_ID,
808
1176
  FIELDS_OPTIONS.NOMINAL_VOLTAGE,
809
1177
  FIELDS_OPTIONS.CONNECTED,
810
- FIELDS_OPTIONS.P0,
811
- FIELDS_OPTIONS.Q0,
1178
+ FIELDS_OPTIONS.MIN_P,
1179
+ FIELDS_OPTIONS.MAX_P,
1180
+ FIELDS_OPTIONS.TARGET_P,
1181
+ FIELDS_OPTIONS.TARGET_Q,
812
1182
  FIELDS_OPTIONS.PROPERTY,
813
1183
  FIELDS_OPTIONS.SUBSTATION_PROPERTY,
814
1184
  FIELDS_OPTIONS.VOLTAGE_LEVEL_PROPERTY
815
1185
  ],
816
- BATTERY: [
1186
+ LOAD: [
817
1187
  FIELDS_OPTIONS.ID,
818
1188
  FIELDS_OPTIONS.NAME,
1189
+ FIELDS_OPTIONS.LOAD_TYPE,
819
1190
  FIELDS_OPTIONS.COUNTRY,
820
1191
  FIELDS_OPTIONS.VOLTAGE_LEVEL_ID,
821
1192
  FIELDS_OPTIONS.NOMINAL_VOLTAGE,
822
1193
  FIELDS_OPTIONS.CONNECTED,
823
- FIELDS_OPTIONS.MIN_P,
824
- FIELDS_OPTIONS.MAX_P,
825
- FIELDS_OPTIONS.TARGET_P,
826
- FIELDS_OPTIONS.TARGET_Q,
1194
+ FIELDS_OPTIONS.P0,
1195
+ FIELDS_OPTIONS.Q0,
827
1196
  FIELDS_OPTIONS.PROPERTY,
828
1197
  FIELDS_OPTIONS.SUBSTATION_PROPERTY,
829
1198
  FIELDS_OPTIONS.VOLTAGE_LEVEL_PROPERTY
@@ -913,6 +1282,24 @@ const fields = {
913
1282
  FIELDS_OPTIONS.SUBSTATION_PROPERTY_2,
914
1283
  FIELDS_OPTIONS.VOLTAGE_LEVEL_PROPERTY_1,
915
1284
  FIELDS_OPTIONS.VOLTAGE_LEVEL_PROPERTY_2
1285
+ ],
1286
+ DANGLING_LINE: [
1287
+ FIELDS_OPTIONS.ID,
1288
+ FIELDS_OPTIONS.NAME,
1289
+ FIELDS_OPTIONS.COUNTRY,
1290
+ FIELDS_OPTIONS.VOLTAGE_LEVEL_ID,
1291
+ FIELDS_OPTIONS.NOMINAL_VOLTAGE,
1292
+ FIELDS_OPTIONS.CONNECTED,
1293
+ FIELDS_OPTIONS.P0,
1294
+ FIELDS_OPTIONS.Q0,
1295
+ FIELDS_OPTIONS.SERIE_RESISTANCE,
1296
+ FIELDS_OPTIONS.SERIE_REACTANCE,
1297
+ FIELDS_OPTIONS.SHUNT_SUSCEPTANCE,
1298
+ FIELDS_OPTIONS.SHUNT_CONDUCTANCE,
1299
+ FIELDS_OPTIONS.PAIRED,
1300
+ FIELDS_OPTIONS.PROPERTY,
1301
+ FIELDS_OPTIONS.SUBSTATION_PROPERTY,
1302
+ FIELDS_OPTIONS.VOLTAGE_LEVEL_PROPERTY
916
1303
  ]
917
1304
  };
918
1305
  export {
@@ -50,7 +50,7 @@ const getOperators = (fieldName, intl) => {
50
50
  OPERATOR_OPTIONS.EXISTS,
51
51
  OPERATOR_OPTIONS.NOT_EXISTS
52
52
  ];
53
- if (field.name === FieldType.ID || field.name === FieldType.VOLTAGE_LEVEL_ID || field.name === FieldType.VOLTAGE_LEVEL_ID_1 || field.name === FieldType.VOLTAGE_LEVEL_ID_2) {
53
+ if (field.name === FieldType.ID || field.name === FieldType.VOLTAGE_LEVEL_ID || field.name === FieldType.VOLTAGE_LEVEL_ID_1 || field.name === FieldType.VOLTAGE_LEVEL_ID_2 || field.name === FieldType.VOLTAGE_LEVEL_ID_3) {
54
54
  stringOperators.push(OPERATOR_OPTIONS.IS_PART_OF);
55
55
  stringOperators.push(OPERATOR_OPTIONS.IS_NOT_PART_OF);
56
56
  }
@@ -37,6 +37,9 @@ export declare enum FieldType {
37
37
  VOLTAGE_REGULATOR_ON = "VOLTAGE_REGULATOR_ON",
38
38
  PLANNED_ACTIVE_POWER_SET_POINT = "PLANNED_ACTIVE_POWER_SET_POINT",
39
39
  RATED_S = "RATED_S",
40
+ RATED_S1 = "RATED_S1",
41
+ RATED_S2 = "RATED_S2",
42
+ RATED_S3 = "RATED_S3",
40
43
  MARGINAL_COST = "MARGINAL_COST",
41
44
  PLANNED_OUTAGE_RATE = "PLANNED_OUTAGE_RATE",
42
45
  FORCED_OUTAGE_RATE = "FORCED_OUTAGE_RATE",
@@ -58,37 +61,79 @@ export declare enum FieldType {
58
61
  SWITCHED_ON_SUSCEPTANCE = "SWITCHED_ON_SUSCEPTANCE",
59
62
  CONNECTED_1 = "CONNECTED_1",
60
63
  CONNECTED_2 = "CONNECTED_2",
64
+ CONNECTED_3 = "CONNECTED_3",
61
65
  VOLTAGE_LEVEL_ID_1 = "VOLTAGE_LEVEL_ID_1",
62
66
  VOLTAGE_LEVEL_ID_2 = "VOLTAGE_LEVEL_ID_2",
67
+ VOLTAGE_LEVEL_ID_3 = "VOLTAGE_LEVEL_ID_3",
63
68
  NOMINAL_VOLTAGE_1 = "NOMINAL_VOLTAGE_1",
64
69
  NOMINAL_VOLTAGE_2 = "NOMINAL_VOLTAGE_2",
70
+ NOMINAL_VOLTAGE_3 = "NOMINAL_VOLTAGE_3",
65
71
  COUNTRY_1 = "COUNTRY_1",
66
72
  COUNTRY_2 = "COUNTRY_2",
67
73
  SERIE_RESISTANCE = "SERIE_RESISTANCE",
74
+ SERIE_RESISTANCE_1 = "SERIE_RESISTANCE_1",
75
+ SERIE_RESISTANCE_2 = "SERIE_RESISTANCE_2",
76
+ SERIE_RESISTANCE_3 = "SERIE_RESISTANCE_3",
68
77
  SERIE_REACTANCE = "SERIE_REACTANCE",
78
+ SERIE_REACTANCE_1 = "SERIE_REACTANCE_1",
79
+ SERIE_REACTANCE_2 = "SERIE_REACTANCE_2",
80
+ SERIE_REACTANCE_3 = "SERIE_REACTANCE_3",
81
+ SHUNT_CONDUCTANCE = "SHUNT_CONDUCTANCE",
69
82
  SHUNT_CONDUCTANCE_1 = "SHUNT_CONDUCTANCE_1",
70
83
  SHUNT_CONDUCTANCE_2 = "SHUNT_CONDUCTANCE_2",
84
+ SHUNT_SUSCEPTANCE = "SHUNT_SUSCEPTANCE",
71
85
  SHUNT_SUSCEPTANCE_1 = "SHUNT_SUSCEPTANCE_1",
72
86
  SHUNT_SUSCEPTANCE_2 = "SHUNT_SUSCEPTANCE_2",
73
87
  MAGNETIZING_CONDUCTANCE = "MAGNETIZING_CONDUCTANCE",
88
+ MAGNETIZING_CONDUCTANCE_1 = "MAGNETIZING_CONDUCTANCE_1",
89
+ MAGNETIZING_CONDUCTANCE_2 = "MAGNETIZING_CONDUCTANCE_2",
90
+ MAGNETIZING_CONDUCTANCE_3 = "MAGNETIZING_CONDUCTANCE_3",
74
91
  MAGNETIZING_SUSCEPTANCE = "MAGNETIZING_SUSCEPTANCE",
92
+ MAGNETIZING_SUSCEPTANCE_1 = "MAGNETIZING_SUSCEPTANCE_1",
93
+ MAGNETIZING_SUSCEPTANCE_2 = "MAGNETIZING_SUSCEPTANCE_2",
94
+ MAGNETIZING_SUSCEPTANCE_3 = "MAGNETIZING_SUSCEPTANCE_3",
75
95
  LOAD_TYPE = "LOAD_TYPE",
96
+ RATED_VOLTAGE_0 = "RATED_VOLTAGE_0",
76
97
  RATED_VOLTAGE_1 = "RATED_VOLTAGE_1",
77
98
  RATED_VOLTAGE_2 = "RATED_VOLTAGE_2",
99
+ RATED_VOLTAGE_3 = "RATED_VOLTAGE_3",
78
100
  HAS_RATIO_TAP_CHANGER = "HAS_RATIO_TAP_CHANGER",
101
+ HAS_RATIO_TAP_CHANGER_1 = "HAS_RATIO_TAP_CHANGER_1",
102
+ HAS_RATIO_TAP_CHANGER_2 = "HAS_RATIO_TAP_CHANGER_2",
103
+ HAS_RATIO_TAP_CHANGER_3 = "HAS_RATIO_TAP_CHANGER_3",
79
104
  LOAD_TAP_CHANGING_CAPABILITIES = "LOAD_TAP_CHANGING_CAPABILITIES",
105
+ LOAD_TAP_CHANGING_CAPABILITIES_1 = "LOAD_TAP_CHANGING_CAPABILITIES_1",
106
+ LOAD_TAP_CHANGING_CAPABILITIES_2 = "LOAD_TAP_CHANGING_CAPABILITIES_2",
107
+ LOAD_TAP_CHANGING_CAPABILITIES_3 = "LOAD_TAP_CHANGING_CAPABILITIES_3",
80
108
  RATIO_REGULATION_MODE = "RATIO_REGULATION_MODE",
109
+ RATIO_REGULATION_MODE_1 = "RATIO_REGULATION_MODE_1",
110
+ RATIO_REGULATION_MODE_2 = "RATIO_REGULATION_MODE_2",
111
+ RATIO_REGULATION_MODE_3 = "RATIO_REGULATION_MODE_3",
81
112
  RATIO_TARGET_V = "RATIO_TARGET_V",
113
+ RATIO_TARGET_V1 = "RATIO_TARGET_V1",
114
+ RATIO_TARGET_V2 = "RATIO_TARGET_V2",
115
+ RATIO_TARGET_V3 = "RATIO_TARGET_V3",
82
116
  HAS_PHASE_TAP_CHANGER = "HAS_PHASE_TAP_CHANGER",
117
+ HAS_PHASE_TAP_CHANGER_1 = "HAS_PHASE_TAP_CHANGER_1",
118
+ HAS_PHASE_TAP_CHANGER_2 = "HAS_PHASE_TAP_CHANGER_2",
119
+ HAS_PHASE_TAP_CHANGER_3 = "HAS_PHASE_TAP_CHANGER_3",
83
120
  PHASE_REGULATION_MODE = "PHASE_REGULATION_MODE",
121
+ PHASE_REGULATION_MODE_1 = "PHASE_REGULATION_MODE_1",
122
+ PHASE_REGULATION_MODE_2 = "PHASE_REGULATION_MODE_2",
123
+ PHASE_REGULATION_MODE_3 = "PHASE_REGULATION_MODE_3",
84
124
  PHASE_REGULATION_VALUE = "PHASE_REGULATION_VALUE",
125
+ PHASE_REGULATION_VALUE_1 = "PHASE_REGULATION_VALUE_1",
126
+ PHASE_REGULATION_VALUE_2 = "PHASE_REGULATION_VALUE_2",
127
+ PHASE_REGULATION_VALUE_3 = "PHASE_REGULATION_VALUE_3",
85
128
  PROPERTY = "FREE_PROPERTIES",
86
129
  SUBSTATION_PROPERTY = "SUBSTATION_PROPERTIES",
87
130
  SUBSTATION_PROPERTY_1 = "SUBSTATION_PROPERTIES_1",
88
131
  SUBSTATION_PROPERTY_2 = "SUBSTATION_PROPERTIES_2",
132
+ SUBSTATION_PROPERTY_3 = "SUBSTATION_PROPERTIES_3",
89
133
  VOLTAGE_LEVEL_PROPERTY = "VOLTAGE_LEVEL_PROPERTIES",
90
134
  VOLTAGE_LEVEL_PROPERTY_1 = "VOLTAGE_LEVEL_PROPERTIES_1",
91
135
  VOLTAGE_LEVEL_PROPERTY_2 = "VOLTAGE_LEVEL_PROPERTIES_2",
136
+ VOLTAGE_LEVEL_PROPERTY_3 = "VOLTAGE_LEVEL_PROPERTIES_3",
92
137
  SVAR_REGULATION_MODE = "SVAR_REGULATION_MODE",
93
138
  VOLTAGE_SET_POINT = "VOLTAGE_SET_POINT",
94
139
  ACTIVE_POWER_SET_POINT = "ACTIVE_POWER_SET_POINT",
@@ -103,6 +148,7 @@ export declare enum FieldType {
103
148
  LOW_VOLTAGE_THRESHOLD = "LOW_VOLTAGE_THRESHOLD",
104
149
  HIGH_VOLTAGE_THRESHOLD = "HIGH_VOLTAGE_THRESHOLD",
105
150
  SUSCEPTANCE_FIX = "SUSCEPTANCE_FIX",
151
+ PAIRED = "PAIRED",
106
152
  CONVERTERS_MODE = "CONVERTERS_MODE",
107
153
  CONVERTER_STATION_ID_1 = "CONVERTER_STATION_ID_1",
108
154
  CONVERTER_STATION_ID_2 = "CONVERTER_STATION_ID_2",