@golemio/energetics 1.13.1-dev.2809036872 → 1.14.0-rc.2809913491
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
|
@@ -67,48 +67,43 @@ FROM generate_series(timestamptz '2026-03-01 00:00:00+00', timestamptz '2026-03-
|
|
|
67
67
|
-- =================================================================================================
|
|
68
68
|
-- Gas, metered (PPAS InternetAVE)
|
|
69
69
|
-- =================================================================================================
|
|
70
|
+
-- Value is core(first day of next month) - core(first day of current month), core being the
|
|
71
|
+
-- cumulative meter state in m3. The corediff rows below carry no weight in that computation any
|
|
72
|
+
-- more; they exist only to seed gas_registration, which picks the (device_serial_number, place_id)
|
|
73
|
+
-- an EIC's 'core' readings must be joined through.
|
|
70
74
|
|
|
71
|
-
-- 27ZG100Z0000CH01
|
|
72
|
-
-- core2 is present and non-zero but must NOT win.
|
|
75
|
+
-- 27ZG100Z0000CH01: single registration, one meter.
|
|
73
76
|
INSERT INTO enapo_measurements (id, id_type, value, "timestamp", var, source, place_id, device_serial_number) VALUES
|
|
74
|
-
('27ZG100Z0000CH01', 'eic', 50.0, '2026-07-01 01:00:00+02', 'corediff', 'ppas_ave_api', '9900001', 'GAS-CH-1')
|
|
75
|
-
('27ZG100Z0000CH01', 'eic', 50.0, '2026-07-02 01:00:00+02', 'corediff', 'ppas_ave_api', '9900001', 'GAS-CH-1'),
|
|
76
|
-
('27ZG100Z0000CH01', 'eic', 50.0, '2026-07-03 01:00:00+02', 'corediff', 'ppas_ave_api', '9900001', 'GAS-CH-1'),
|
|
77
|
-
('27ZG100Z0000CH01', 'eic', 55.0, '2026-07-01 01:00:00+02', 'core2', 'ppas_ave_api', '9900001', 'GAS-CH-1'),
|
|
78
|
-
('27ZG100Z0000CH01', 'eic', 55.0, '2026-07-02 01:00:00+02', 'core2', 'ppas_ave_api', '9900001', 'GAS-CH-1'),
|
|
79
|
-
('27ZG100Z0000CH01', 'eic', 55.0, '2026-07-03 01:00:00+02', 'core2', 'ppas_ave_api', '9900001', 'GAS-CH-1'),
|
|
80
|
-
-- the cumulative meter state: present, and deliberately unused (max - min across an EIC's
|
|
81
|
-
-- registrations is the distance between unrelated counters, so it is not a fallback)
|
|
82
|
-
('27ZG100Z0000CH01', 'eic', 900000.0, '2026-07-01 01:00:00+02', 'core', 'ppas_ave_api', '9900001', 'GAS-CH-1'),
|
|
83
|
-
('27ZG100Z0000CH01', 'eic', 900150.0, '2026-07-03 01:00:00+02', 'core', 'ppas_ave_api', '9900001', 'GAS-CH-1');
|
|
84
|
-
|
|
85
|
-
-- 2026-06: corediff has data, core2 is present but ALL ZERO. 0 is not NULL, so a bare COALESCE
|
|
86
|
-
-- would return a flat-zero Nm3 series here - exactly what production does for some EICs. The
|
|
87
|
-
-- expected result is 120 m3 from corediff.
|
|
88
|
-
INSERT INTO enapo_measurements (id, id_type, value, "timestamp", var, source, place_id, device_serial_number) VALUES
|
|
89
|
-
('27ZG100Z0000CH01', 'eic', 60.0, '2026-06-01 01:00:00+02', 'corediff', 'ppas_ave_api', '9900001', 'GAS-CH-1'),
|
|
90
|
-
('27ZG100Z0000CH01', 'eic', 60.0, '2026-06-02 01:00:00+02', 'corediff', 'ppas_ave_api', '9900001', 'GAS-CH-1'),
|
|
91
|
-
('27ZG100Z0000CH01', 'eic', 0.0, '2026-06-01 01:00:00+02', 'core2', 'ppas_ave_api', '9900001', 'GAS-CH-1'),
|
|
92
|
-
('27ZG100Z0000CH01', 'eic', 0.0, '2026-06-02 01:00:00+02', 'core2', 'ppas_ave_api', '9900001', 'GAS-CH-1');
|
|
77
|
+
('27ZG100Z0000CH01', 'eic', 50.0, '2026-07-01 01:00:00+02', 'corediff', 'ppas_ave_api', '9900001', 'GAS-CH-1');
|
|
93
78
|
|
|
94
|
-
--
|
|
95
|
-
--
|
|
79
|
+
-- Core readings on the first day of each month. 2026-05-01 is deliberately missing, so both April
|
|
80
|
+
-- (missing its "next month" boundary) and May (missing its "current month" boundary) come back
|
|
81
|
+
-- null - a diff needs both sides.
|
|
96
82
|
INSERT INTO enapo_measurements (id, id_type, value, "timestamp", var, source, place_id, device_serial_number) VALUES
|
|
97
|
-
('27ZG100Z0000CH01', 'eic',
|
|
98
|
-
('27ZG100Z0000CH01', 'eic',
|
|
83
|
+
('27ZG100Z0000CH01', 'eic', 900000.0, '2026-04-01 01:00:00+02', 'core', 'ppas_ave_api', '9900001', 'GAS-CH-1'),
|
|
84
|
+
('27ZG100Z0000CH01', 'eic', 900060.0, '2026-06-01 01:00:00+02', 'core', 'ppas_ave_api', '9900001', 'GAS-CH-1'),
|
|
85
|
+
('27ZG100Z0000CH01', 'eic', 900180.0, '2026-07-01 01:00:00+02', 'core', 'ppas_ave_api', '9900001', 'GAS-CH-1'),
|
|
86
|
+
('27ZG100Z0000CH01', 'eic', 900330.0, '2026-08-01 01:00:00+02', 'core', 'ppas_ave_api', '9900001', 'GAS-CH-1');
|
|
87
|
+
-- June = 900180 - 900060 = 120; July = 900330 - 900180 = 150.
|
|
99
88
|
|
|
100
89
|
-- 27ZG100Z0000CH02, 2026-07: TWO place_ids, ONE meter serial - two live registrations of the same
|
|
101
|
-
-- physical meter
|
|
102
|
-
--
|
|
90
|
+
-- physical meter. gas_registration picks one per serial (the most recently reporting one, here
|
|
91
|
+
-- 9900012), so only that place_id's core readings feed the diff: 100 m3, NOT 200.
|
|
103
92
|
INSERT INTO enapo_measurements (id, id_type, value, "timestamp", var, source, place_id, device_serial_number) VALUES
|
|
104
93
|
('27ZG100Z0000CH02', 'eic', 100.0, '2026-07-01 01:00:00+02', 'corediff', 'ppas_ave_api', '9900011', 'GAS-CH-DUP'),
|
|
105
|
-
('27ZG100Z0000CH02', 'eic', 100.0, '2026-07-01 01:00:00+02', 'corediff', 'ppas_ave_api', '9900012', 'GAS-CH-DUP')
|
|
94
|
+
('27ZG100Z0000CH02', 'eic', 100.0, '2026-07-01 01:00:00+02', 'corediff', 'ppas_ave_api', '9900012', 'GAS-CH-DUP'),
|
|
95
|
+
('27ZG100Z0000CH02', 'eic', 500000.0, '2026-07-01 01:00:00+02', 'core', 'ppas_ave_api', '9900012', 'GAS-CH-DUP'),
|
|
96
|
+
('27ZG100Z0000CH02', 'eic', 500100.0, '2026-08-01 01:00:00+02', 'core', 'ppas_ave_api', '9900012', 'GAS-CH-DUP');
|
|
106
97
|
|
|
107
98
|
-- 27ZG100Z0000CH03, 2026-07: TWO place_ids, TWO serials - genuinely two meters on one delivery
|
|
108
|
-
-- point.
|
|
99
|
+
-- point. Each registration gets its own diff and they add up: 100 + 100 = 200 m3.
|
|
109
100
|
INSERT INTO enapo_measurements (id, id_type, value, "timestamp", var, source, place_id, device_serial_number) VALUES
|
|
110
101
|
('27ZG100Z0000CH03', 'eic', 100.0, '2026-07-01 01:00:00+02', 'corediff', 'ppas_ave_api', '9900021', 'GAS-CH-A'),
|
|
111
|
-
('27ZG100Z0000CH03', 'eic', 100.0, '2026-07-01 01:00:00+02', 'corediff', 'ppas_ave_api', '9900022', 'GAS-CH-B')
|
|
102
|
+
('27ZG100Z0000CH03', 'eic', 100.0, '2026-07-01 01:00:00+02', 'corediff', 'ppas_ave_api', '9900022', 'GAS-CH-B'),
|
|
103
|
+
('27ZG100Z0000CH03', 'eic', 700000.0, '2026-07-01 01:00:00+02', 'core', 'ppas_ave_api', '9900021', 'GAS-CH-A'),
|
|
104
|
+
('27ZG100Z0000CH03', 'eic', 700100.0, '2026-08-01 01:00:00+02', 'core', 'ppas_ave_api', '9900021', 'GAS-CH-A'),
|
|
105
|
+
('27ZG100Z0000CH03', 'eic', 800000.0, '2026-07-01 01:00:00+02', 'core', 'ppas_ave_api', '9900022', 'GAS-CH-B'),
|
|
106
|
+
('27ZG100Z0000CH03', 'eic', 800100.0, '2026-08-01 01:00:00+02', 'core', 'ppas_ave_api', '9900022', 'GAS-CH-B');
|
|
112
107
|
|
|
113
108
|
|
|
114
109
|
-- =================================================================================================
|
|
@@ -73,19 +73,17 @@ gas_registration AS (
|
|
|
73
73
|
GROUP BY em.id, em.device_serial_number, em.place_id
|
|
74
74
|
ORDER BY em.id, em.device_serial_number, max(em."timestamp") DESC, em.place_id DESC
|
|
75
75
|
),
|
|
76
|
-
|
|
77
|
-
|
|
78
|
-
|
|
79
|
-
|
|
80
|
-
|
|
81
|
-
|
|
82
|
-
|
|
83
|
-
|
|
84
|
-
|
|
85
|
-
|
|
86
|
-
|
|
87
|
-
FILTER (WHERE em.var = 'core2')
|
|
88
|
-
) AS days_covered
|
|
76
|
+
gas_core_month AS (
|
|
77
|
+
-- Cumulative 'core' reading (m3) at the first measured hour of each first-of-month day, kept
|
|
78
|
+
-- per (id, device_serial_number, place_id) - an id can carry several registrations (see
|
|
79
|
+
-- gas_registration) whose diffs must be summed separately, not collapsed into one reading.
|
|
80
|
+
SELECT DISTINCT ON (em.id, em.device_serial_number, em.place_id,
|
|
81
|
+
date_trunc('month', em."timestamp" AT TIME ZONE 'Europe/Prague'))
|
|
82
|
+
em.id,
|
|
83
|
+
em.device_serial_number,
|
|
84
|
+
em.place_id,
|
|
85
|
+
date_trunc('month', em."timestamp" AT TIME ZONE 'Europe/Prague')::date AS month_start,
|
|
86
|
+
em.value
|
|
89
87
|
FROM enapo_measurements em
|
|
90
88
|
CROSS JOIN bounds b
|
|
91
89
|
INNER JOIN gas_registration gr
|
|
@@ -93,10 +91,29 @@ gas_metered AS (
|
|
|
93
91
|
AND gr.device_serial_number = em.device_serial_number
|
|
94
92
|
AND gr.place_id = em.place_id
|
|
95
93
|
WHERE em.source = 'ppas_ave_api'
|
|
96
|
-
AND em.var
|
|
94
|
+
AND em.var = 'core'
|
|
95
|
+
AND (em."timestamp" AT TIME ZONE 'Europe/Prague')::date
|
|
96
|
+
= date_trunc('month', em."timestamp" AT TIME ZONE 'Europe/Prague')::date
|
|
97
97
|
AND em."timestamp" >= b.month_from_tstz
|
|
98
|
-
AND em."timestamp" < b.month_to_tstz
|
|
99
|
-
|
|
98
|
+
AND em."timestamp" < (b.month_to_tstz + interval '1 month')
|
|
99
|
+
ORDER BY em.id, em.device_serial_number, em.place_id,
|
|
100
|
+
date_trunc('month', em."timestamp" AT TIME ZONE 'Europe/Prague'), em."timestamp"
|
|
101
|
+
),
|
|
102
|
+
gas_metered AS (
|
|
103
|
+
SELECT
|
|
104
|
+
cur.id AS place_id,
|
|
105
|
+
cur.month_start AS period_start,
|
|
106
|
+
-- A negative diff means the meter was exchanged/reset between the two boundary readings -
|
|
107
|
+
-- null rather than a nonsense negative volume.
|
|
108
|
+
(CASE WHEN sum(nxt.value - cur.value) < 0 THEN NULL ELSE sum(nxt.value - cur.value) END) AS m3_sum,
|
|
109
|
+
((cur.month_start + interval '1 month')::date - cur.month_start) AS days_covered
|
|
110
|
+
FROM gas_core_month cur
|
|
111
|
+
INNER JOIN gas_core_month nxt
|
|
112
|
+
ON nxt.id = cur.id
|
|
113
|
+
AND nxt.device_serial_number = cur.device_serial_number
|
|
114
|
+
AND nxt.place_id = cur.place_id
|
|
115
|
+
AND nxt.month_start = (cur.month_start + interval '1 month')::date
|
|
116
|
+
GROUP BY cur.id, cur.month_start
|
|
100
117
|
),
|
|
101
118
|
|
|
102
119
|
distribution_device AS (
|
|
@@ -253,15 +270,6 @@ invoice_year AS (
|
|
|
253
270
|
GROUP BY source, place_id, date_trunc('year', period_start)::date
|
|
254
271
|
),
|
|
255
272
|
|
|
256
|
-
gas_combustion_heat AS (
|
|
257
|
-
SELECT DISTINCT ON (d.eic)
|
|
258
|
-
d.eic,
|
|
259
|
-
NULLIF(d.combustion_heat, 0)::numeric AS heat_kwh_per_m3
|
|
260
|
-
FROM distribution_device d
|
|
261
|
-
WHERE NULLIF(d.combustion_heat, 0) IS NOT NULL
|
|
262
|
-
ORDER BY d.eic, d.date_to DESC
|
|
263
|
-
),
|
|
264
|
-
|
|
265
273
|
porsenna_period AS (
|
|
266
274
|
SELECT *
|
|
267
275
|
FROM (
|
|
@@ -314,16 +322,15 @@ monthly AS (
|
|
|
314
322
|
'ppas_ave_api',
|
|
315
323
|
'monthly',
|
|
316
324
|
g.period_start,
|
|
317
|
-
|
|
318
|
-
|
|
319
|
-
|
|
320
|
-
|
|
325
|
+
g.m3_sum,
|
|
326
|
+
'm3',
|
|
327
|
+
NULL::numeric,
|
|
328
|
+
'core',
|
|
321
329
|
g.days_covered,
|
|
322
330
|
false,
|
|
323
331
|
'{}'::text[]
|
|
324
332
|
FROM point p
|
|
325
333
|
INNER JOIN gas_metered g ON g.place_id = p.place_id
|
|
326
|
-
LEFT JOIN gas_combustion_heat ch ON ch.eic = p.place_id
|
|
327
334
|
WHERE p.commodity = 'gas'
|
|
328
335
|
|
|
329
336
|
UNION ALL
|
|
@@ -438,7 +445,9 @@ FROM (
|
|
|
438
445
|
SELECT * FROM yearly
|
|
439
446
|
) all_periods
|
|
440
447
|
WHERE value IS NOT NULL
|
|
441
|
-
GROUP BY gid, place_id, commodity, source, unit, period_type, period_start
|
|
448
|
+
GROUP BY gid, place_id, commodity, source, unit, period_type, period_start
|
|
449
|
+
with no data;
|
|
450
|
+
|
|
442
451
|
|
|
443
452
|
COMMENT ON MATERIALIZED VIEW mv_enapo_om_consumption IS
|
|
444
453
|
'Monthly and yearly consumption per consumption point per source, for the last 48 months, behind the DeD building detail endpoint. One row per (gid, place_id, commodity, source, unit, period_type, period_start). Refreshed by EnapoConsumptionHistoryRefreshTask (integration engine).';
|
|
@@ -446,9 +455,9 @@ COMMENT ON MATERIALIZED VIEW mv_enapo_om_consumption IS
|
|
|
446
455
|
COMMENT ON COLUMN mv_enapo_om_consumption.place_id IS
|
|
447
456
|
'EAN / EIC / OM code, as in enapo_gid_mapping.place_id - NOT enapo_measurements.place_id, which holds a PPAS-internal place id. Measurements are joined through enapo_measurements.id.';
|
|
448
457
|
COMMENT ON COLUMN mv_enapo_om_consumption.value IS
|
|
449
|
-
'Consumption for the period in `unit`. Electricity is kWh (the upstream T1_Wh_total naming is wrong); metered gas is m3
|
|
458
|
+
'Consumption for the period in `unit`. Electricity is kWh (the upstream T1_Wh_total naming is wrong); metered gas is m3, the difference between the cumulative `core` reading on the first day of the next month and the first day of the current month; invoiced gas follows the invoice unit; Porsenna carries its own unit.';
|
|
450
459
|
COMMENT ON COLUMN mv_enapo_om_consumption.value_kwh IS
|
|
451
|
-
'Derived comparable energy: for gas, normometers_nm3 * combustion_heat (verified exact). NULL when the conversion inputs are missing - `value` + `unit` stay authoritative.';
|
|
460
|
+
'Derived comparable energy: for gas, normometers_nm3 * combustion_heat (verified exact). NULL when the conversion inputs are missing - `value` + `unit` stay authoritative. Always NULL for metered gas (no normometers_nm3 input).';
|
|
452
461
|
COMMENT ON COLUMN mv_enapo_om_consumption.internal_source_var IS
|
|
453
462
|
'Which enapo_measurements.var produced the row; NULL for invoice and Porsenna rows. Provenance for debugging, not part of the public response.';
|
|
454
463
|
COMMENT ON COLUMN mv_enapo_om_consumption.invoice_ids IS
|
|
@@ -740,9 +740,9 @@ Sloupec `value` míchá **kumulativní stavy měřidla** a **rozdíly za interva
|
|
|
740
740
|
|
|
741
741
|
| `source` | komodita | `var` | granularita | význam | jednotka | agregace |
|
|
742
742
|
| -------------- | ----------- | ---------------------------------- | ----------- | -------------------------------------------------- | -------- | --------------------------------------------------- |
|
|
743
|
-
| `ppas_ave_api` | plyn | `corediff` | hodinová | **rozdíl** (`OperatingDifference`) | m³ | `sum
|
|
744
|
-
| `ppas_ave_api` | plyn | `core2` | hodinová | **rozdíl**, přepočtený (`ConvertDifference`) | Nm³ | `sum`,
|
|
745
|
-
| `ppas_ave_api` | plyn | `core` | hodinová | **kumulativní** stav měřidla (`OperatingAmount`) | m³ | **
|
|
743
|
+
| `ppas_ave_api` | plyn | `corediff` | hodinová | **rozdíl** (`OperatingDifference`) | m³ | `sum`, jen registrace (viz níže) |
|
|
744
|
+
| `ppas_ave_api` | plyn | `core2` | hodinová | **rozdíl**, přepočtený (`ConvertDifference`) | Nm³ | `sum`, jen registrace (viz níže) |
|
|
745
|
+
| `ppas_ave_api` | plyn | `core` | hodinová | **kumulativní** stav měřidla (`OperatingAmount`) | m³ | rozdíl 1. dne měsíce a 1. dne dalšího ← **primární v `mv_enapo_om_consumption.gas_metered`** |
|
|
746
746
|
| `predi_input` | elektřina | `EActi_VT_NT_DaySum` | denní | **odvozený součet** VT+NT | **kWh** | `sum` ← **primární** |
|
|
747
747
|
| `predi_input` | elektřina | `EActi_VT_DaySum` / `_NT_DaySum` | denní | denní energie; NT je dnes všude nulové | **kWh** | `sum` (jen fallback) |
|
|
748
748
|
| `predi_input` | elektřina | `EFwActi_VT` / `_NT` | 15 min | průměrný **výkon**, tedy 4× energie | kW | **nepoužívat** (`sum / 4` by byly kWh) |
|
|
@@ -757,7 +757,7 @@ Další ověřené vlastnosti dat, na které agregace spoléhá:
|
|
|
757
757
|
|
|
758
758
|
- `id_type` **není spolehlivý** — v produkci je aspoň jedno elektroměrové EAN uložené s `id_type = 'eic'`, takže join na měření jde výhradně přes `enapo_measurements.id` a `id_type` se nefiltruje
|
|
759
759
|
- `enapo_gid_mapping.place_id` je **kód EAN/EIC**, zatímco `enapo_measurements.place_id` je interní PPAS place id — join `place_id = place_id` vrací nula řádků a vypadá jako „nejsou data“
|
|
760
|
-
- jedno EIC může mít několik `place_id`. Pokud jejich počet přesahuje počet různých `device_serial_number`, jde o dvě živé registrace jednoho fyzického měřidla a sečtení by spotřebu zdvojilo — agregace proto pracuje na granularitě `(id, device_serial_number)`.
|
|
760
|
+
- jedno EIC může mít několik `place_id`. Pokud jejich počet přesahuje počet různých `device_serial_number`, jde o dvě živé registrace jednoho fyzického měřidla a sečtení by spotřebu zdvojilo — agregace proto pracuje na granularitě `(id, device_serial_number)`. `mv_enapo_om_consumption.gas_metered` proto nejdřív vybere aktivní registraci (CTE `gas_registration`, podle poslední aktivity v `corediff`/`core2`) a teprve pro tu spočítá `core(1. den dalšího měsíce) - core(1. den měsíce)`; napříč celým EIC (bez vazby na registraci) by `core` rozdíl byl rozpětím mezi dvěma nesouvisejícími počítadly.
|
|
761
761
|
|
|
762
762
|
#### _PPAS Distribution API_
|
|
763
763
|
|