@gadgetinc/dateilager 0.1.0-rc.1

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (38) hide show
  1. package/README.md +1 -0
  2. package/dist/cjs/binary-client.d.ts +89 -0
  3. package/dist/cjs/binary-client.js +125 -0
  4. package/dist/cjs/binary-client.js.map +1 -0
  5. package/dist/cjs/grpc-client.d.ts +163 -0
  6. package/dist/cjs/grpc-client.js +320 -0
  7. package/dist/cjs/grpc-client.js.map +1 -0
  8. package/dist/cjs/index.d.ts +2 -0
  9. package/dist/cjs/index.js +19 -0
  10. package/dist/cjs/index.js.map +1 -0
  11. package/dist/cjs/internal/telemetry.d.ts +1 -0
  12. package/dist/cjs/internal/telemetry.js +30 -0
  13. package/dist/cjs/internal/telemetry.js.map +1 -0
  14. package/dist/cjs/pb/fs_pb.client.d.ts +113 -0
  15. package/dist/cjs/pb/fs_pb.client.js +101 -0
  16. package/dist/cjs/pb/fs_pb.client.js.map +1 -0
  17. package/dist/cjs/pb/fs_pb.d.ts +494 -0
  18. package/dist/cjs/pb/fs_pb.js +1082 -0
  19. package/dist/cjs/pb/fs_pb.js.map +1 -0
  20. package/dist/esm/binary-client.d.ts +89 -0
  21. package/dist/esm/binary-client.js +118 -0
  22. package/dist/esm/binary-client.js.map +1 -0
  23. package/dist/esm/grpc-client.d.ts +163 -0
  24. package/dist/esm/grpc-client.js +314 -0
  25. package/dist/esm/grpc-client.js.map +1 -0
  26. package/dist/esm/index.d.ts +2 -0
  27. package/dist/esm/index.js +3 -0
  28. package/dist/esm/index.js.map +1 -0
  29. package/dist/esm/internal/telemetry.d.ts +1 -0
  30. package/dist/esm/internal/telemetry.js +26 -0
  31. package/dist/esm/internal/telemetry.js.map +1 -0
  32. package/dist/esm/pb/fs_pb.client.d.ts +113 -0
  33. package/dist/esm/pb/fs_pb.client.js +97 -0
  34. package/dist/esm/pb/fs_pb.client.js.map +1 -0
  35. package/dist/esm/pb/fs_pb.d.ts +494 -0
  36. package/dist/esm/pb/fs_pb.js +1079 -0
  37. package/dist/esm/pb/fs_pb.js.map +1 -0
  38. package/package.json +59 -0
@@ -0,0 +1,1082 @@
1
+ "use strict";
2
+ Object.defineProperty(exports, "__esModule", { value: true });
3
+ exports.Fs = exports.ResetResponse = exports.ResetRequest = exports.SnapshotResponse = exports.SnapshotRequest = exports.InspectResponse = exports.InspectRequest = exports.UpdateResponse = exports.UpdateRequest = exports.GetCompressResponse = exports.GetCompressRequest = exports.GetResponse = exports.GetRequest = exports.ObjectQuery = exports.Objekt = exports.ListProjectsResponse = exports.ListProjectsRequest = exports.Project = exports.DeleteProjectResponse = exports.DeleteProjectRequest = exports.NewProjectResponse = exports.NewProjectRequest = exports.GetCompressResponse_Format = void 0;
4
+ /* eslint-disable */
5
+ // @generated by protobuf-ts 2.6.0 with parameter long_type_bigint,ts_nocheck,eslint_disable,add_pb_suffix
6
+ // @generated from protobuf file "fs.proto" (package "pb", syntax proto3)
7
+ // tslint:disable
8
+ // @ts-nocheck
9
+ const runtime_rpc_1 = require("@protobuf-ts/runtime-rpc");
10
+ const runtime_1 = require("@protobuf-ts/runtime");
11
+ const runtime_2 = require("@protobuf-ts/runtime");
12
+ const runtime_3 = require("@protobuf-ts/runtime");
13
+ const runtime_4 = require("@protobuf-ts/runtime");
14
+ const runtime_5 = require("@protobuf-ts/runtime");
15
+ /**
16
+ * @generated from protobuf enum pb.GetCompressResponse.Format
17
+ */
18
+ var GetCompressResponse_Format;
19
+ (function (GetCompressResponse_Format) {
20
+ /**
21
+ * @generated from protobuf enum value: S2_TAR = 0;
22
+ */
23
+ GetCompressResponse_Format[GetCompressResponse_Format["S2_TAR"] = 0] = "S2_TAR";
24
+ })(GetCompressResponse_Format = exports.GetCompressResponse_Format || (exports.GetCompressResponse_Format = {}));
25
+ // @generated message type with reflection information, may provide speed optimized methods
26
+ class NewProjectRequest$Type extends runtime_5.MessageType {
27
+ constructor() {
28
+ super("pb.NewProjectRequest", [
29
+ { no: 1, name: "id", kind: "scalar", T: 3 /*ScalarType.INT64*/, L: 0 /*LongType.BIGINT*/ },
30
+ { no: 2, name: "template", kind: "scalar", opt: true, T: 3 /*ScalarType.INT64*/, L: 0 /*LongType.BIGINT*/ },
31
+ { no: 3, name: "pack_patterns", kind: "scalar", repeat: 2 /*RepeatType.UNPACKED*/, T: 9 /*ScalarType.STRING*/ }
32
+ ]);
33
+ }
34
+ create(value) {
35
+ const message = { id: 0n, packPatterns: [] };
36
+ globalThis.Object.defineProperty(message, runtime_4.MESSAGE_TYPE, { enumerable: false, value: this });
37
+ if (value !== undefined)
38
+ (0, runtime_3.reflectionMergePartial)(this, message, value);
39
+ return message;
40
+ }
41
+ internalBinaryRead(reader, length, options, target) {
42
+ let message = target ?? this.create(), end = reader.pos + length;
43
+ while (reader.pos < end) {
44
+ let [fieldNo, wireType] = reader.tag();
45
+ switch (fieldNo) {
46
+ case /* int64 id */ 1:
47
+ message.id = reader.int64().toBigInt();
48
+ break;
49
+ case /* optional int64 template */ 2:
50
+ message.template = reader.int64().toBigInt();
51
+ break;
52
+ case /* repeated string pack_patterns */ 3:
53
+ message.packPatterns.push(reader.string());
54
+ break;
55
+ default:
56
+ let u = options.readUnknownField;
57
+ if (u === "throw")
58
+ throw new globalThis.Error(`Unknown field ${fieldNo} (wire type ${wireType}) for ${this.typeName}`);
59
+ let d = reader.skip(wireType);
60
+ if (u !== false)
61
+ (u === true ? runtime_2.UnknownFieldHandler.onRead : u)(this.typeName, message, fieldNo, wireType, d);
62
+ }
63
+ }
64
+ return message;
65
+ }
66
+ internalBinaryWrite(message, writer, options) {
67
+ /* int64 id = 1; */
68
+ if (message.id !== 0n)
69
+ writer.tag(1, runtime_1.WireType.Varint).int64(message.id);
70
+ /* optional int64 template = 2; */
71
+ if (message.template !== undefined)
72
+ writer.tag(2, runtime_1.WireType.Varint).int64(message.template);
73
+ /* repeated string pack_patterns = 3; */
74
+ for (let i = 0; i < message.packPatterns.length; i++)
75
+ writer.tag(3, runtime_1.WireType.LengthDelimited).string(message.packPatterns[i]);
76
+ let u = options.writeUnknownFields;
77
+ if (u !== false)
78
+ (u == true ? runtime_2.UnknownFieldHandler.onWrite : u)(this.typeName, message, writer);
79
+ return writer;
80
+ }
81
+ }
82
+ /**
83
+ * @generated MessageType for protobuf message pb.NewProjectRequest
84
+ */
85
+ exports.NewProjectRequest = new NewProjectRequest$Type();
86
+ // @generated message type with reflection information, may provide speed optimized methods
87
+ class NewProjectResponse$Type extends runtime_5.MessageType {
88
+ constructor() {
89
+ super("pb.NewProjectResponse", []);
90
+ }
91
+ create(value) {
92
+ const message = {};
93
+ globalThis.Object.defineProperty(message, runtime_4.MESSAGE_TYPE, { enumerable: false, value: this });
94
+ if (value !== undefined)
95
+ (0, runtime_3.reflectionMergePartial)(this, message, value);
96
+ return message;
97
+ }
98
+ internalBinaryRead(reader, length, options, target) {
99
+ return target ?? this.create();
100
+ }
101
+ internalBinaryWrite(message, writer, options) {
102
+ let u = options.writeUnknownFields;
103
+ if (u !== false)
104
+ (u == true ? runtime_2.UnknownFieldHandler.onWrite : u)(this.typeName, message, writer);
105
+ return writer;
106
+ }
107
+ }
108
+ /**
109
+ * @generated MessageType for protobuf message pb.NewProjectResponse
110
+ */
111
+ exports.NewProjectResponse = new NewProjectResponse$Type();
112
+ // @generated message type with reflection information, may provide speed optimized methods
113
+ class DeleteProjectRequest$Type extends runtime_5.MessageType {
114
+ constructor() {
115
+ super("pb.DeleteProjectRequest", [
116
+ { no: 1, name: "project", kind: "scalar", T: 3 /*ScalarType.INT64*/, L: 0 /*LongType.BIGINT*/ }
117
+ ]);
118
+ }
119
+ create(value) {
120
+ const message = { project: 0n };
121
+ globalThis.Object.defineProperty(message, runtime_4.MESSAGE_TYPE, { enumerable: false, value: this });
122
+ if (value !== undefined)
123
+ (0, runtime_3.reflectionMergePartial)(this, message, value);
124
+ return message;
125
+ }
126
+ internalBinaryRead(reader, length, options, target) {
127
+ let message = target ?? this.create(), end = reader.pos + length;
128
+ while (reader.pos < end) {
129
+ let [fieldNo, wireType] = reader.tag();
130
+ switch (fieldNo) {
131
+ case /* int64 project */ 1:
132
+ message.project = reader.int64().toBigInt();
133
+ break;
134
+ default:
135
+ let u = options.readUnknownField;
136
+ if (u === "throw")
137
+ throw new globalThis.Error(`Unknown field ${fieldNo} (wire type ${wireType}) for ${this.typeName}`);
138
+ let d = reader.skip(wireType);
139
+ if (u !== false)
140
+ (u === true ? runtime_2.UnknownFieldHandler.onRead : u)(this.typeName, message, fieldNo, wireType, d);
141
+ }
142
+ }
143
+ return message;
144
+ }
145
+ internalBinaryWrite(message, writer, options) {
146
+ /* int64 project = 1; */
147
+ if (message.project !== 0n)
148
+ writer.tag(1, runtime_1.WireType.Varint).int64(message.project);
149
+ let u = options.writeUnknownFields;
150
+ if (u !== false)
151
+ (u == true ? runtime_2.UnknownFieldHandler.onWrite : u)(this.typeName, message, writer);
152
+ return writer;
153
+ }
154
+ }
155
+ /**
156
+ * @generated MessageType for protobuf message pb.DeleteProjectRequest
157
+ */
158
+ exports.DeleteProjectRequest = new DeleteProjectRequest$Type();
159
+ // @generated message type with reflection information, may provide speed optimized methods
160
+ class DeleteProjectResponse$Type extends runtime_5.MessageType {
161
+ constructor() {
162
+ super("pb.DeleteProjectResponse", []);
163
+ }
164
+ create(value) {
165
+ const message = {};
166
+ globalThis.Object.defineProperty(message, runtime_4.MESSAGE_TYPE, { enumerable: false, value: this });
167
+ if (value !== undefined)
168
+ (0, runtime_3.reflectionMergePartial)(this, message, value);
169
+ return message;
170
+ }
171
+ internalBinaryRead(reader, length, options, target) {
172
+ return target ?? this.create();
173
+ }
174
+ internalBinaryWrite(message, writer, options) {
175
+ let u = options.writeUnknownFields;
176
+ if (u !== false)
177
+ (u == true ? runtime_2.UnknownFieldHandler.onWrite : u)(this.typeName, message, writer);
178
+ return writer;
179
+ }
180
+ }
181
+ /**
182
+ * @generated MessageType for protobuf message pb.DeleteProjectResponse
183
+ */
184
+ exports.DeleteProjectResponse = new DeleteProjectResponse$Type();
185
+ // @generated message type with reflection information, may provide speed optimized methods
186
+ class Project$Type extends runtime_5.MessageType {
187
+ constructor() {
188
+ super("pb.Project", [
189
+ { no: 1, name: "id", kind: "scalar", T: 3 /*ScalarType.INT64*/, L: 0 /*LongType.BIGINT*/ },
190
+ { no: 2, name: "version", kind: "scalar", T: 3 /*ScalarType.INT64*/, L: 0 /*LongType.BIGINT*/ }
191
+ ]);
192
+ }
193
+ create(value) {
194
+ const message = { id: 0n, version: 0n };
195
+ globalThis.Object.defineProperty(message, runtime_4.MESSAGE_TYPE, { enumerable: false, value: this });
196
+ if (value !== undefined)
197
+ (0, runtime_3.reflectionMergePartial)(this, message, value);
198
+ return message;
199
+ }
200
+ internalBinaryRead(reader, length, options, target) {
201
+ let message = target ?? this.create(), end = reader.pos + length;
202
+ while (reader.pos < end) {
203
+ let [fieldNo, wireType] = reader.tag();
204
+ switch (fieldNo) {
205
+ case /* int64 id */ 1:
206
+ message.id = reader.int64().toBigInt();
207
+ break;
208
+ case /* int64 version */ 2:
209
+ message.version = reader.int64().toBigInt();
210
+ break;
211
+ default:
212
+ let u = options.readUnknownField;
213
+ if (u === "throw")
214
+ throw new globalThis.Error(`Unknown field ${fieldNo} (wire type ${wireType}) for ${this.typeName}`);
215
+ let d = reader.skip(wireType);
216
+ if (u !== false)
217
+ (u === true ? runtime_2.UnknownFieldHandler.onRead : u)(this.typeName, message, fieldNo, wireType, d);
218
+ }
219
+ }
220
+ return message;
221
+ }
222
+ internalBinaryWrite(message, writer, options) {
223
+ /* int64 id = 1; */
224
+ if (message.id !== 0n)
225
+ writer.tag(1, runtime_1.WireType.Varint).int64(message.id);
226
+ /* int64 version = 2; */
227
+ if (message.version !== 0n)
228
+ writer.tag(2, runtime_1.WireType.Varint).int64(message.version);
229
+ let u = options.writeUnknownFields;
230
+ if (u !== false)
231
+ (u == true ? runtime_2.UnknownFieldHandler.onWrite : u)(this.typeName, message, writer);
232
+ return writer;
233
+ }
234
+ }
235
+ /**
236
+ * @generated MessageType for protobuf message pb.Project
237
+ */
238
+ exports.Project = new Project$Type();
239
+ // @generated message type with reflection information, may provide speed optimized methods
240
+ class ListProjectsRequest$Type extends runtime_5.MessageType {
241
+ constructor() {
242
+ super("pb.ListProjectsRequest", []);
243
+ }
244
+ create(value) {
245
+ const message = {};
246
+ globalThis.Object.defineProperty(message, runtime_4.MESSAGE_TYPE, { enumerable: false, value: this });
247
+ if (value !== undefined)
248
+ (0, runtime_3.reflectionMergePartial)(this, message, value);
249
+ return message;
250
+ }
251
+ internalBinaryRead(reader, length, options, target) {
252
+ return target ?? this.create();
253
+ }
254
+ internalBinaryWrite(message, writer, options) {
255
+ let u = options.writeUnknownFields;
256
+ if (u !== false)
257
+ (u == true ? runtime_2.UnknownFieldHandler.onWrite : u)(this.typeName, message, writer);
258
+ return writer;
259
+ }
260
+ }
261
+ /**
262
+ * @generated MessageType for protobuf message pb.ListProjectsRequest
263
+ */
264
+ exports.ListProjectsRequest = new ListProjectsRequest$Type();
265
+ // @generated message type with reflection information, may provide speed optimized methods
266
+ class ListProjectsResponse$Type extends runtime_5.MessageType {
267
+ constructor() {
268
+ super("pb.ListProjectsResponse", [
269
+ { no: 1, name: "projects", kind: "message", repeat: 1 /*RepeatType.PACKED*/, T: () => exports.Project }
270
+ ]);
271
+ }
272
+ create(value) {
273
+ const message = { projects: [] };
274
+ globalThis.Object.defineProperty(message, runtime_4.MESSAGE_TYPE, { enumerable: false, value: this });
275
+ if (value !== undefined)
276
+ (0, runtime_3.reflectionMergePartial)(this, message, value);
277
+ return message;
278
+ }
279
+ internalBinaryRead(reader, length, options, target) {
280
+ let message = target ?? this.create(), end = reader.pos + length;
281
+ while (reader.pos < end) {
282
+ let [fieldNo, wireType] = reader.tag();
283
+ switch (fieldNo) {
284
+ case /* repeated pb.Project projects */ 1:
285
+ message.projects.push(exports.Project.internalBinaryRead(reader, reader.uint32(), options));
286
+ break;
287
+ default:
288
+ let u = options.readUnknownField;
289
+ if (u === "throw")
290
+ throw new globalThis.Error(`Unknown field ${fieldNo} (wire type ${wireType}) for ${this.typeName}`);
291
+ let d = reader.skip(wireType);
292
+ if (u !== false)
293
+ (u === true ? runtime_2.UnknownFieldHandler.onRead : u)(this.typeName, message, fieldNo, wireType, d);
294
+ }
295
+ }
296
+ return message;
297
+ }
298
+ internalBinaryWrite(message, writer, options) {
299
+ /* repeated pb.Project projects = 1; */
300
+ for (let i = 0; i < message.projects.length; i++)
301
+ exports.Project.internalBinaryWrite(message.projects[i], writer.tag(1, runtime_1.WireType.LengthDelimited).fork(), options).join();
302
+ let u = options.writeUnknownFields;
303
+ if (u !== false)
304
+ (u == true ? runtime_2.UnknownFieldHandler.onWrite : u)(this.typeName, message, writer);
305
+ return writer;
306
+ }
307
+ }
308
+ /**
309
+ * @generated MessageType for protobuf message pb.ListProjectsResponse
310
+ */
311
+ exports.ListProjectsResponse = new ListProjectsResponse$Type();
312
+ // @generated message type with reflection information, may provide speed optimized methods
313
+ class Objekt$Type extends runtime_5.MessageType {
314
+ constructor() {
315
+ super("pb.Objekt", [
316
+ { no: 1, name: "path", kind: "scalar", T: 9 /*ScalarType.STRING*/ },
317
+ { no: 2, name: "mode", kind: "scalar", T: 3 /*ScalarType.INT64*/, L: 0 /*LongType.BIGINT*/ },
318
+ { no: 3, name: "size", kind: "scalar", T: 3 /*ScalarType.INT64*/, L: 0 /*LongType.BIGINT*/ },
319
+ { no: 4, name: "deleted", kind: "scalar", T: 8 /*ScalarType.BOOL*/ },
320
+ { no: 5, name: "content", kind: "scalar", opt: true, T: 12 /*ScalarType.BYTES*/ }
321
+ ]);
322
+ }
323
+ create(value) {
324
+ const message = { path: "", mode: 0n, size: 0n, deleted: false };
325
+ globalThis.Object.defineProperty(message, runtime_4.MESSAGE_TYPE, { enumerable: false, value: this });
326
+ if (value !== undefined)
327
+ (0, runtime_3.reflectionMergePartial)(this, message, value);
328
+ return message;
329
+ }
330
+ internalBinaryRead(reader, length, options, target) {
331
+ let message = target ?? this.create(), end = reader.pos + length;
332
+ while (reader.pos < end) {
333
+ let [fieldNo, wireType] = reader.tag();
334
+ switch (fieldNo) {
335
+ case /* string path */ 1:
336
+ message.path = reader.string();
337
+ break;
338
+ case /* int64 mode */ 2:
339
+ message.mode = reader.int64().toBigInt();
340
+ break;
341
+ case /* int64 size */ 3:
342
+ message.size = reader.int64().toBigInt();
343
+ break;
344
+ case /* bool deleted */ 4:
345
+ message.deleted = reader.bool();
346
+ break;
347
+ case /* optional bytes content */ 5:
348
+ message.content = reader.bytes();
349
+ break;
350
+ default:
351
+ let u = options.readUnknownField;
352
+ if (u === "throw")
353
+ throw new globalThis.Error(`Unknown field ${fieldNo} (wire type ${wireType}) for ${this.typeName}`);
354
+ let d = reader.skip(wireType);
355
+ if (u !== false)
356
+ (u === true ? runtime_2.UnknownFieldHandler.onRead : u)(this.typeName, message, fieldNo, wireType, d);
357
+ }
358
+ }
359
+ return message;
360
+ }
361
+ internalBinaryWrite(message, writer, options) {
362
+ /* string path = 1; */
363
+ if (message.path !== "")
364
+ writer.tag(1, runtime_1.WireType.LengthDelimited).string(message.path);
365
+ /* int64 mode = 2; */
366
+ if (message.mode !== 0n)
367
+ writer.tag(2, runtime_1.WireType.Varint).int64(message.mode);
368
+ /* int64 size = 3; */
369
+ if (message.size !== 0n)
370
+ writer.tag(3, runtime_1.WireType.Varint).int64(message.size);
371
+ /* bool deleted = 4; */
372
+ if (message.deleted !== false)
373
+ writer.tag(4, runtime_1.WireType.Varint).bool(message.deleted);
374
+ /* optional bytes content = 5; */
375
+ if (message.content !== undefined)
376
+ writer.tag(5, runtime_1.WireType.LengthDelimited).bytes(message.content);
377
+ let u = options.writeUnknownFields;
378
+ if (u !== false)
379
+ (u == true ? runtime_2.UnknownFieldHandler.onWrite : u)(this.typeName, message, writer);
380
+ return writer;
381
+ }
382
+ }
383
+ /**
384
+ * @generated MessageType for protobuf message pb.Objekt
385
+ */
386
+ exports.Objekt = new Objekt$Type();
387
+ // @generated message type with reflection information, may provide speed optimized methods
388
+ class ObjectQuery$Type extends runtime_5.MessageType {
389
+ constructor() {
390
+ super("pb.ObjectQuery", [
391
+ { no: 1, name: "path", kind: "scalar", T: 9 /*ScalarType.STRING*/ },
392
+ { no: 2, name: "is_prefix", kind: "scalar", T: 8 /*ScalarType.BOOL*/ },
393
+ { no: 3, name: "with_content", kind: "scalar", T: 8 /*ScalarType.BOOL*/ },
394
+ { no: 4, name: "ignores", kind: "scalar", repeat: 2 /*RepeatType.UNPACKED*/, T: 9 /*ScalarType.STRING*/ }
395
+ ]);
396
+ }
397
+ create(value) {
398
+ const message = { path: "", isPrefix: false, withContent: false, ignores: [] };
399
+ globalThis.Object.defineProperty(message, runtime_4.MESSAGE_TYPE, { enumerable: false, value: this });
400
+ if (value !== undefined)
401
+ (0, runtime_3.reflectionMergePartial)(this, message, value);
402
+ return message;
403
+ }
404
+ internalBinaryRead(reader, length, options, target) {
405
+ let message = target ?? this.create(), end = reader.pos + length;
406
+ while (reader.pos < end) {
407
+ let [fieldNo, wireType] = reader.tag();
408
+ switch (fieldNo) {
409
+ case /* string path */ 1:
410
+ message.path = reader.string();
411
+ break;
412
+ case /* bool is_prefix */ 2:
413
+ message.isPrefix = reader.bool();
414
+ break;
415
+ case /* bool with_content */ 3:
416
+ message.withContent = reader.bool();
417
+ break;
418
+ case /* repeated string ignores */ 4:
419
+ message.ignores.push(reader.string());
420
+ break;
421
+ default:
422
+ let u = options.readUnknownField;
423
+ if (u === "throw")
424
+ throw new globalThis.Error(`Unknown field ${fieldNo} (wire type ${wireType}) for ${this.typeName}`);
425
+ let d = reader.skip(wireType);
426
+ if (u !== false)
427
+ (u === true ? runtime_2.UnknownFieldHandler.onRead : u)(this.typeName, message, fieldNo, wireType, d);
428
+ }
429
+ }
430
+ return message;
431
+ }
432
+ internalBinaryWrite(message, writer, options) {
433
+ /* string path = 1; */
434
+ if (message.path !== "")
435
+ writer.tag(1, runtime_1.WireType.LengthDelimited).string(message.path);
436
+ /* bool is_prefix = 2; */
437
+ if (message.isPrefix !== false)
438
+ writer.tag(2, runtime_1.WireType.Varint).bool(message.isPrefix);
439
+ /* bool with_content = 3; */
440
+ if (message.withContent !== false)
441
+ writer.tag(3, runtime_1.WireType.Varint).bool(message.withContent);
442
+ /* repeated string ignores = 4; */
443
+ for (let i = 0; i < message.ignores.length; i++)
444
+ writer.tag(4, runtime_1.WireType.LengthDelimited).string(message.ignores[i]);
445
+ let u = options.writeUnknownFields;
446
+ if (u !== false)
447
+ (u == true ? runtime_2.UnknownFieldHandler.onWrite : u)(this.typeName, message, writer);
448
+ return writer;
449
+ }
450
+ }
451
+ /**
452
+ * @generated MessageType for protobuf message pb.ObjectQuery
453
+ */
454
+ exports.ObjectQuery = new ObjectQuery$Type();
455
+ // @generated message type with reflection information, may provide speed optimized methods
456
+ class GetRequest$Type extends runtime_5.MessageType {
457
+ constructor() {
458
+ super("pb.GetRequest", [
459
+ { no: 1, name: "project", kind: "scalar", T: 3 /*ScalarType.INT64*/, L: 0 /*LongType.BIGINT*/ },
460
+ { no: 2, name: "from_version", kind: "scalar", opt: true, T: 3 /*ScalarType.INT64*/, L: 0 /*LongType.BIGINT*/ },
461
+ { no: 3, name: "to_version", kind: "scalar", opt: true, T: 3 /*ScalarType.INT64*/, L: 0 /*LongType.BIGINT*/ },
462
+ { no: 4, name: "queries", kind: "message", repeat: 1 /*RepeatType.PACKED*/, T: () => exports.ObjectQuery }
463
+ ]);
464
+ }
465
+ create(value) {
466
+ const message = { project: 0n, queries: [] };
467
+ globalThis.Object.defineProperty(message, runtime_4.MESSAGE_TYPE, { enumerable: false, value: this });
468
+ if (value !== undefined)
469
+ (0, runtime_3.reflectionMergePartial)(this, message, value);
470
+ return message;
471
+ }
472
+ internalBinaryRead(reader, length, options, target) {
473
+ let message = target ?? this.create(), end = reader.pos + length;
474
+ while (reader.pos < end) {
475
+ let [fieldNo, wireType] = reader.tag();
476
+ switch (fieldNo) {
477
+ case /* int64 project */ 1:
478
+ message.project = reader.int64().toBigInt();
479
+ break;
480
+ case /* optional int64 from_version */ 2:
481
+ message.fromVersion = reader.int64().toBigInt();
482
+ break;
483
+ case /* optional int64 to_version */ 3:
484
+ message.toVersion = reader.int64().toBigInt();
485
+ break;
486
+ case /* repeated pb.ObjectQuery queries */ 4:
487
+ message.queries.push(exports.ObjectQuery.internalBinaryRead(reader, reader.uint32(), options));
488
+ break;
489
+ default:
490
+ let u = options.readUnknownField;
491
+ if (u === "throw")
492
+ throw new globalThis.Error(`Unknown field ${fieldNo} (wire type ${wireType}) for ${this.typeName}`);
493
+ let d = reader.skip(wireType);
494
+ if (u !== false)
495
+ (u === true ? runtime_2.UnknownFieldHandler.onRead : u)(this.typeName, message, fieldNo, wireType, d);
496
+ }
497
+ }
498
+ return message;
499
+ }
500
+ internalBinaryWrite(message, writer, options) {
501
+ /* int64 project = 1; */
502
+ if (message.project !== 0n)
503
+ writer.tag(1, runtime_1.WireType.Varint).int64(message.project);
504
+ /* optional int64 from_version = 2; */
505
+ if (message.fromVersion !== undefined)
506
+ writer.tag(2, runtime_1.WireType.Varint).int64(message.fromVersion);
507
+ /* optional int64 to_version = 3; */
508
+ if (message.toVersion !== undefined)
509
+ writer.tag(3, runtime_1.WireType.Varint).int64(message.toVersion);
510
+ /* repeated pb.ObjectQuery queries = 4; */
511
+ for (let i = 0; i < message.queries.length; i++)
512
+ exports.ObjectQuery.internalBinaryWrite(message.queries[i], writer.tag(4, runtime_1.WireType.LengthDelimited).fork(), options).join();
513
+ let u = options.writeUnknownFields;
514
+ if (u !== false)
515
+ (u == true ? runtime_2.UnknownFieldHandler.onWrite : u)(this.typeName, message, writer);
516
+ return writer;
517
+ }
518
+ }
519
+ /**
520
+ * @generated MessageType for protobuf message pb.GetRequest
521
+ */
522
+ exports.GetRequest = new GetRequest$Type();
523
+ // @generated message type with reflection information, may provide speed optimized methods
524
+ class GetResponse$Type extends runtime_5.MessageType {
525
+ constructor() {
526
+ super("pb.GetResponse", [
527
+ { no: 1, name: "version", kind: "scalar", T: 3 /*ScalarType.INT64*/, L: 0 /*LongType.BIGINT*/ },
528
+ { no: 2, name: "object", kind: "message", T: () => exports.Objekt }
529
+ ]);
530
+ }
531
+ create(value) {
532
+ const message = { version: 0n };
533
+ globalThis.Object.defineProperty(message, runtime_4.MESSAGE_TYPE, { enumerable: false, value: this });
534
+ if (value !== undefined)
535
+ (0, runtime_3.reflectionMergePartial)(this, message, value);
536
+ return message;
537
+ }
538
+ internalBinaryRead(reader, length, options, target) {
539
+ let message = target ?? this.create(), end = reader.pos + length;
540
+ while (reader.pos < end) {
541
+ let [fieldNo, wireType] = reader.tag();
542
+ switch (fieldNo) {
543
+ case /* int64 version */ 1:
544
+ message.version = reader.int64().toBigInt();
545
+ break;
546
+ case /* pb.Objekt object */ 2:
547
+ message.object = exports.Objekt.internalBinaryRead(reader, reader.uint32(), options, message.object);
548
+ break;
549
+ default:
550
+ let u = options.readUnknownField;
551
+ if (u === "throw")
552
+ throw new globalThis.Error(`Unknown field ${fieldNo} (wire type ${wireType}) for ${this.typeName}`);
553
+ let d = reader.skip(wireType);
554
+ if (u !== false)
555
+ (u === true ? runtime_2.UnknownFieldHandler.onRead : u)(this.typeName, message, fieldNo, wireType, d);
556
+ }
557
+ }
558
+ return message;
559
+ }
560
+ internalBinaryWrite(message, writer, options) {
561
+ /* int64 version = 1; */
562
+ if (message.version !== 0n)
563
+ writer.tag(1, runtime_1.WireType.Varint).int64(message.version);
564
+ /* pb.Objekt object = 2; */
565
+ if (message.object)
566
+ exports.Objekt.internalBinaryWrite(message.object, writer.tag(2, runtime_1.WireType.LengthDelimited).fork(), options).join();
567
+ let u = options.writeUnknownFields;
568
+ if (u !== false)
569
+ (u == true ? runtime_2.UnknownFieldHandler.onWrite : u)(this.typeName, message, writer);
570
+ return writer;
571
+ }
572
+ }
573
+ /**
574
+ * @generated MessageType for protobuf message pb.GetResponse
575
+ */
576
+ exports.GetResponse = new GetResponse$Type();
577
+ // @generated message type with reflection information, may provide speed optimized methods
578
+ class GetCompressRequest$Type extends runtime_5.MessageType {
579
+ constructor() {
580
+ super("pb.GetCompressRequest", [
581
+ { no: 1, name: "project", kind: "scalar", T: 3 /*ScalarType.INT64*/, L: 0 /*LongType.BIGINT*/ },
582
+ { no: 2, name: "from_version", kind: "scalar", opt: true, T: 3 /*ScalarType.INT64*/, L: 0 /*LongType.BIGINT*/ },
583
+ { no: 3, name: "to_version", kind: "scalar", opt: true, T: 3 /*ScalarType.INT64*/, L: 0 /*LongType.BIGINT*/ },
584
+ { no: 5, name: "queries", kind: "message", repeat: 1 /*RepeatType.PACKED*/, T: () => exports.ObjectQuery }
585
+ ]);
586
+ }
587
+ create(value) {
588
+ const message = { project: 0n, queries: [] };
589
+ globalThis.Object.defineProperty(message, runtime_4.MESSAGE_TYPE, { enumerable: false, value: this });
590
+ if (value !== undefined)
591
+ (0, runtime_3.reflectionMergePartial)(this, message, value);
592
+ return message;
593
+ }
594
+ internalBinaryRead(reader, length, options, target) {
595
+ let message = target ?? this.create(), end = reader.pos + length;
596
+ while (reader.pos < end) {
597
+ let [fieldNo, wireType] = reader.tag();
598
+ switch (fieldNo) {
599
+ case /* int64 project */ 1:
600
+ message.project = reader.int64().toBigInt();
601
+ break;
602
+ case /* optional int64 from_version */ 2:
603
+ message.fromVersion = reader.int64().toBigInt();
604
+ break;
605
+ case /* optional int64 to_version */ 3:
606
+ message.toVersion = reader.int64().toBigInt();
607
+ break;
608
+ case /* repeated pb.ObjectQuery queries */ 5:
609
+ message.queries.push(exports.ObjectQuery.internalBinaryRead(reader, reader.uint32(), options));
610
+ break;
611
+ default:
612
+ let u = options.readUnknownField;
613
+ if (u === "throw")
614
+ throw new globalThis.Error(`Unknown field ${fieldNo} (wire type ${wireType}) for ${this.typeName}`);
615
+ let d = reader.skip(wireType);
616
+ if (u !== false)
617
+ (u === true ? runtime_2.UnknownFieldHandler.onRead : u)(this.typeName, message, fieldNo, wireType, d);
618
+ }
619
+ }
620
+ return message;
621
+ }
622
+ internalBinaryWrite(message, writer, options) {
623
+ /* int64 project = 1; */
624
+ if (message.project !== 0n)
625
+ writer.tag(1, runtime_1.WireType.Varint).int64(message.project);
626
+ /* optional int64 from_version = 2; */
627
+ if (message.fromVersion !== undefined)
628
+ writer.tag(2, runtime_1.WireType.Varint).int64(message.fromVersion);
629
+ /* optional int64 to_version = 3; */
630
+ if (message.toVersion !== undefined)
631
+ writer.tag(3, runtime_1.WireType.Varint).int64(message.toVersion);
632
+ /* repeated pb.ObjectQuery queries = 5; */
633
+ for (let i = 0; i < message.queries.length; i++)
634
+ exports.ObjectQuery.internalBinaryWrite(message.queries[i], writer.tag(5, runtime_1.WireType.LengthDelimited).fork(), options).join();
635
+ let u = options.writeUnknownFields;
636
+ if (u !== false)
637
+ (u == true ? runtime_2.UnknownFieldHandler.onWrite : u)(this.typeName, message, writer);
638
+ return writer;
639
+ }
640
+ }
641
+ /**
642
+ * @generated MessageType for protobuf message pb.GetCompressRequest
643
+ */
644
+ exports.GetCompressRequest = new GetCompressRequest$Type();
645
+ // @generated message type with reflection information, may provide speed optimized methods
646
+ class GetCompressResponse$Type extends runtime_5.MessageType {
647
+ constructor() {
648
+ super("pb.GetCompressResponse", [
649
+ { no: 1, name: "version", kind: "scalar", T: 3 /*ScalarType.INT64*/, L: 0 /*LongType.BIGINT*/ },
650
+ { no: 2, name: "format", kind: "enum", T: () => ["pb.GetCompressResponse.Format", GetCompressResponse_Format] },
651
+ { no: 3, name: "bytes", kind: "scalar", T: 12 /*ScalarType.BYTES*/ }
652
+ ]);
653
+ }
654
+ create(value) {
655
+ const message = { version: 0n, format: 0, bytes: new Uint8Array(0) };
656
+ globalThis.Object.defineProperty(message, runtime_4.MESSAGE_TYPE, { enumerable: false, value: this });
657
+ if (value !== undefined)
658
+ (0, runtime_3.reflectionMergePartial)(this, message, value);
659
+ return message;
660
+ }
661
+ internalBinaryRead(reader, length, options, target) {
662
+ let message = target ?? this.create(), end = reader.pos + length;
663
+ while (reader.pos < end) {
664
+ let [fieldNo, wireType] = reader.tag();
665
+ switch (fieldNo) {
666
+ case /* int64 version */ 1:
667
+ message.version = reader.int64().toBigInt();
668
+ break;
669
+ case /* pb.GetCompressResponse.Format format */ 2:
670
+ message.format = reader.int32();
671
+ break;
672
+ case /* bytes bytes */ 3:
673
+ message.bytes = reader.bytes();
674
+ break;
675
+ default:
676
+ let u = options.readUnknownField;
677
+ if (u === "throw")
678
+ throw new globalThis.Error(`Unknown field ${fieldNo} (wire type ${wireType}) for ${this.typeName}`);
679
+ let d = reader.skip(wireType);
680
+ if (u !== false)
681
+ (u === true ? runtime_2.UnknownFieldHandler.onRead : u)(this.typeName, message, fieldNo, wireType, d);
682
+ }
683
+ }
684
+ return message;
685
+ }
686
+ internalBinaryWrite(message, writer, options) {
687
+ /* int64 version = 1; */
688
+ if (message.version !== 0n)
689
+ writer.tag(1, runtime_1.WireType.Varint).int64(message.version);
690
+ /* pb.GetCompressResponse.Format format = 2; */
691
+ if (message.format !== 0)
692
+ writer.tag(2, runtime_1.WireType.Varint).int32(message.format);
693
+ /* bytes bytes = 3; */
694
+ if (message.bytes.length)
695
+ writer.tag(3, runtime_1.WireType.LengthDelimited).bytes(message.bytes);
696
+ let u = options.writeUnknownFields;
697
+ if (u !== false)
698
+ (u == true ? runtime_2.UnknownFieldHandler.onWrite : u)(this.typeName, message, writer);
699
+ return writer;
700
+ }
701
+ }
702
+ /**
703
+ * @generated MessageType for protobuf message pb.GetCompressResponse
704
+ */
705
+ exports.GetCompressResponse = new GetCompressResponse$Type();
706
+ // @generated message type with reflection information, may provide speed optimized methods
707
+ class UpdateRequest$Type extends runtime_5.MessageType {
708
+ constructor() {
709
+ super("pb.UpdateRequest", [
710
+ { no: 1, name: "project", kind: "scalar", T: 3 /*ScalarType.INT64*/, L: 0 /*LongType.BIGINT*/ },
711
+ { no: 2, name: "object", kind: "message", T: () => exports.Objekt }
712
+ ]);
713
+ }
714
+ create(value) {
715
+ const message = { project: 0n };
716
+ globalThis.Object.defineProperty(message, runtime_4.MESSAGE_TYPE, { enumerable: false, value: this });
717
+ if (value !== undefined)
718
+ (0, runtime_3.reflectionMergePartial)(this, message, value);
719
+ return message;
720
+ }
721
+ internalBinaryRead(reader, length, options, target) {
722
+ let message = target ?? this.create(), end = reader.pos + length;
723
+ while (reader.pos < end) {
724
+ let [fieldNo, wireType] = reader.tag();
725
+ switch (fieldNo) {
726
+ case /* int64 project */ 1:
727
+ message.project = reader.int64().toBigInt();
728
+ break;
729
+ case /* pb.Objekt object */ 2:
730
+ message.object = exports.Objekt.internalBinaryRead(reader, reader.uint32(), options, message.object);
731
+ break;
732
+ default:
733
+ let u = options.readUnknownField;
734
+ if (u === "throw")
735
+ throw new globalThis.Error(`Unknown field ${fieldNo} (wire type ${wireType}) for ${this.typeName}`);
736
+ let d = reader.skip(wireType);
737
+ if (u !== false)
738
+ (u === true ? runtime_2.UnknownFieldHandler.onRead : u)(this.typeName, message, fieldNo, wireType, d);
739
+ }
740
+ }
741
+ return message;
742
+ }
743
+ internalBinaryWrite(message, writer, options) {
744
+ /* int64 project = 1; */
745
+ if (message.project !== 0n)
746
+ writer.tag(1, runtime_1.WireType.Varint).int64(message.project);
747
+ /* pb.Objekt object = 2; */
748
+ if (message.object)
749
+ exports.Objekt.internalBinaryWrite(message.object, writer.tag(2, runtime_1.WireType.LengthDelimited).fork(), options).join();
750
+ let u = options.writeUnknownFields;
751
+ if (u !== false)
752
+ (u == true ? runtime_2.UnknownFieldHandler.onWrite : u)(this.typeName, message, writer);
753
+ return writer;
754
+ }
755
+ }
756
+ /**
757
+ * @generated MessageType for protobuf message pb.UpdateRequest
758
+ */
759
+ exports.UpdateRequest = new UpdateRequest$Type();
760
+ // @generated message type with reflection information, may provide speed optimized methods
761
+ class UpdateResponse$Type extends runtime_5.MessageType {
762
+ constructor() {
763
+ super("pb.UpdateResponse", [
764
+ { no: 1, name: "version", kind: "scalar", T: 3 /*ScalarType.INT64*/, L: 0 /*LongType.BIGINT*/ }
765
+ ]);
766
+ }
767
+ create(value) {
768
+ const message = { version: 0n };
769
+ globalThis.Object.defineProperty(message, runtime_4.MESSAGE_TYPE, { enumerable: false, value: this });
770
+ if (value !== undefined)
771
+ (0, runtime_3.reflectionMergePartial)(this, message, value);
772
+ return message;
773
+ }
774
+ internalBinaryRead(reader, length, options, target) {
775
+ let message = target ?? this.create(), end = reader.pos + length;
776
+ while (reader.pos < end) {
777
+ let [fieldNo, wireType] = reader.tag();
778
+ switch (fieldNo) {
779
+ case /* int64 version */ 1:
780
+ message.version = reader.int64().toBigInt();
781
+ break;
782
+ default:
783
+ let u = options.readUnknownField;
784
+ if (u === "throw")
785
+ throw new globalThis.Error(`Unknown field ${fieldNo} (wire type ${wireType}) for ${this.typeName}`);
786
+ let d = reader.skip(wireType);
787
+ if (u !== false)
788
+ (u === true ? runtime_2.UnknownFieldHandler.onRead : u)(this.typeName, message, fieldNo, wireType, d);
789
+ }
790
+ }
791
+ return message;
792
+ }
793
+ internalBinaryWrite(message, writer, options) {
794
+ /* int64 version = 1; */
795
+ if (message.version !== 0n)
796
+ writer.tag(1, runtime_1.WireType.Varint).int64(message.version);
797
+ let u = options.writeUnknownFields;
798
+ if (u !== false)
799
+ (u == true ? runtime_2.UnknownFieldHandler.onWrite : u)(this.typeName, message, writer);
800
+ return writer;
801
+ }
802
+ }
803
+ /**
804
+ * @generated MessageType for protobuf message pb.UpdateResponse
805
+ */
806
+ exports.UpdateResponse = new UpdateResponse$Type();
807
+ // @generated message type with reflection information, may provide speed optimized methods
808
+ class InspectRequest$Type extends runtime_5.MessageType {
809
+ constructor() {
810
+ super("pb.InspectRequest", [
811
+ { no: 1, name: "project", kind: "scalar", T: 3 /*ScalarType.INT64*/, L: 0 /*LongType.BIGINT*/ }
812
+ ]);
813
+ }
814
+ create(value) {
815
+ const message = { project: 0n };
816
+ globalThis.Object.defineProperty(message, runtime_4.MESSAGE_TYPE, { enumerable: false, value: this });
817
+ if (value !== undefined)
818
+ (0, runtime_3.reflectionMergePartial)(this, message, value);
819
+ return message;
820
+ }
821
+ internalBinaryRead(reader, length, options, target) {
822
+ let message = target ?? this.create(), end = reader.pos + length;
823
+ while (reader.pos < end) {
824
+ let [fieldNo, wireType] = reader.tag();
825
+ switch (fieldNo) {
826
+ case /* int64 project */ 1:
827
+ message.project = reader.int64().toBigInt();
828
+ break;
829
+ default:
830
+ let u = options.readUnknownField;
831
+ if (u === "throw")
832
+ throw new globalThis.Error(`Unknown field ${fieldNo} (wire type ${wireType}) for ${this.typeName}`);
833
+ let d = reader.skip(wireType);
834
+ if (u !== false)
835
+ (u === true ? runtime_2.UnknownFieldHandler.onRead : u)(this.typeName, message, fieldNo, wireType, d);
836
+ }
837
+ }
838
+ return message;
839
+ }
840
+ internalBinaryWrite(message, writer, options) {
841
+ /* int64 project = 1; */
842
+ if (message.project !== 0n)
843
+ writer.tag(1, runtime_1.WireType.Varint).int64(message.project);
844
+ let u = options.writeUnknownFields;
845
+ if (u !== false)
846
+ (u == true ? runtime_2.UnknownFieldHandler.onWrite : u)(this.typeName, message, writer);
847
+ return writer;
848
+ }
849
+ }
850
+ /**
851
+ * @generated MessageType for protobuf message pb.InspectRequest
852
+ */
853
+ exports.InspectRequest = new InspectRequest$Type();
854
+ // @generated message type with reflection information, may provide speed optimized methods
855
+ class InspectResponse$Type extends runtime_5.MessageType {
856
+ constructor() {
857
+ super("pb.InspectResponse", [
858
+ { no: 1, name: "project", kind: "scalar", T: 3 /*ScalarType.INT64*/, L: 0 /*LongType.BIGINT*/ },
859
+ { no: 2, name: "latest_version", kind: "scalar", T: 3 /*ScalarType.INT64*/, L: 0 /*LongType.BIGINT*/ },
860
+ { no: 3, name: "live_objects_count", kind: "scalar", T: 3 /*ScalarType.INT64*/, L: 0 /*LongType.BIGINT*/ },
861
+ { no: 4, name: "total_objects_count", kind: "scalar", T: 3 /*ScalarType.INT64*/, L: 0 /*LongType.BIGINT*/ }
862
+ ]);
863
+ }
864
+ create(value) {
865
+ const message = { project: 0n, latestVersion: 0n, liveObjectsCount: 0n, totalObjectsCount: 0n };
866
+ globalThis.Object.defineProperty(message, runtime_4.MESSAGE_TYPE, { enumerable: false, value: this });
867
+ if (value !== undefined)
868
+ (0, runtime_3.reflectionMergePartial)(this, message, value);
869
+ return message;
870
+ }
871
+ internalBinaryRead(reader, length, options, target) {
872
+ let message = target ?? this.create(), end = reader.pos + length;
873
+ while (reader.pos < end) {
874
+ let [fieldNo, wireType] = reader.tag();
875
+ switch (fieldNo) {
876
+ case /* int64 project */ 1:
877
+ message.project = reader.int64().toBigInt();
878
+ break;
879
+ case /* int64 latest_version */ 2:
880
+ message.latestVersion = reader.int64().toBigInt();
881
+ break;
882
+ case /* int64 live_objects_count */ 3:
883
+ message.liveObjectsCount = reader.int64().toBigInt();
884
+ break;
885
+ case /* int64 total_objects_count */ 4:
886
+ message.totalObjectsCount = reader.int64().toBigInt();
887
+ break;
888
+ default:
889
+ let u = options.readUnknownField;
890
+ if (u === "throw")
891
+ throw new globalThis.Error(`Unknown field ${fieldNo} (wire type ${wireType}) for ${this.typeName}`);
892
+ let d = reader.skip(wireType);
893
+ if (u !== false)
894
+ (u === true ? runtime_2.UnknownFieldHandler.onRead : u)(this.typeName, message, fieldNo, wireType, d);
895
+ }
896
+ }
897
+ return message;
898
+ }
899
+ internalBinaryWrite(message, writer, options) {
900
+ /* int64 project = 1; */
901
+ if (message.project !== 0n)
902
+ writer.tag(1, runtime_1.WireType.Varint).int64(message.project);
903
+ /* int64 latest_version = 2; */
904
+ if (message.latestVersion !== 0n)
905
+ writer.tag(2, runtime_1.WireType.Varint).int64(message.latestVersion);
906
+ /* int64 live_objects_count = 3; */
907
+ if (message.liveObjectsCount !== 0n)
908
+ writer.tag(3, runtime_1.WireType.Varint).int64(message.liveObjectsCount);
909
+ /* int64 total_objects_count = 4; */
910
+ if (message.totalObjectsCount !== 0n)
911
+ writer.tag(4, runtime_1.WireType.Varint).int64(message.totalObjectsCount);
912
+ let u = options.writeUnknownFields;
913
+ if (u !== false)
914
+ (u == true ? runtime_2.UnknownFieldHandler.onWrite : u)(this.typeName, message, writer);
915
+ return writer;
916
+ }
917
+ }
918
+ /**
919
+ * @generated MessageType for protobuf message pb.InspectResponse
920
+ */
921
+ exports.InspectResponse = new InspectResponse$Type();
922
+ // @generated message type with reflection information, may provide speed optimized methods
923
+ class SnapshotRequest$Type extends runtime_5.MessageType {
924
+ constructor() {
925
+ super("pb.SnapshotRequest", []);
926
+ }
927
+ create(value) {
928
+ const message = {};
929
+ globalThis.Object.defineProperty(message, runtime_4.MESSAGE_TYPE, { enumerable: false, value: this });
930
+ if (value !== undefined)
931
+ (0, runtime_3.reflectionMergePartial)(this, message, value);
932
+ return message;
933
+ }
934
+ internalBinaryRead(reader, length, options, target) {
935
+ return target ?? this.create();
936
+ }
937
+ internalBinaryWrite(message, writer, options) {
938
+ let u = options.writeUnknownFields;
939
+ if (u !== false)
940
+ (u == true ? runtime_2.UnknownFieldHandler.onWrite : u)(this.typeName, message, writer);
941
+ return writer;
942
+ }
943
+ }
944
+ /**
945
+ * @generated MessageType for protobuf message pb.SnapshotRequest
946
+ */
947
+ exports.SnapshotRequest = new SnapshotRequest$Type();
948
+ // @generated message type with reflection information, may provide speed optimized methods
949
+ class SnapshotResponse$Type extends runtime_5.MessageType {
950
+ constructor() {
951
+ super("pb.SnapshotResponse", [
952
+ { no: 1, name: "projects", kind: "message", repeat: 1 /*RepeatType.PACKED*/, T: () => exports.Project }
953
+ ]);
954
+ }
955
+ create(value) {
956
+ const message = { projects: [] };
957
+ globalThis.Object.defineProperty(message, runtime_4.MESSAGE_TYPE, { enumerable: false, value: this });
958
+ if (value !== undefined)
959
+ (0, runtime_3.reflectionMergePartial)(this, message, value);
960
+ return message;
961
+ }
962
+ internalBinaryRead(reader, length, options, target) {
963
+ let message = target ?? this.create(), end = reader.pos + length;
964
+ while (reader.pos < end) {
965
+ let [fieldNo, wireType] = reader.tag();
966
+ switch (fieldNo) {
967
+ case /* repeated pb.Project projects */ 1:
968
+ message.projects.push(exports.Project.internalBinaryRead(reader, reader.uint32(), options));
969
+ break;
970
+ default:
971
+ let u = options.readUnknownField;
972
+ if (u === "throw")
973
+ throw new globalThis.Error(`Unknown field ${fieldNo} (wire type ${wireType}) for ${this.typeName}`);
974
+ let d = reader.skip(wireType);
975
+ if (u !== false)
976
+ (u === true ? runtime_2.UnknownFieldHandler.onRead : u)(this.typeName, message, fieldNo, wireType, d);
977
+ }
978
+ }
979
+ return message;
980
+ }
981
+ internalBinaryWrite(message, writer, options) {
982
+ /* repeated pb.Project projects = 1; */
983
+ for (let i = 0; i < message.projects.length; i++)
984
+ exports.Project.internalBinaryWrite(message.projects[i], writer.tag(1, runtime_1.WireType.LengthDelimited).fork(), options).join();
985
+ let u = options.writeUnknownFields;
986
+ if (u !== false)
987
+ (u == true ? runtime_2.UnknownFieldHandler.onWrite : u)(this.typeName, message, writer);
988
+ return writer;
989
+ }
990
+ }
991
+ /**
992
+ * @generated MessageType for protobuf message pb.SnapshotResponse
993
+ */
994
+ exports.SnapshotResponse = new SnapshotResponse$Type();
995
+ // @generated message type with reflection information, may provide speed optimized methods
996
+ class ResetRequest$Type extends runtime_5.MessageType {
997
+ constructor() {
998
+ super("pb.ResetRequest", [
999
+ { no: 1, name: "projects", kind: "message", repeat: 1 /*RepeatType.PACKED*/, T: () => exports.Project }
1000
+ ]);
1001
+ }
1002
+ create(value) {
1003
+ const message = { projects: [] };
1004
+ globalThis.Object.defineProperty(message, runtime_4.MESSAGE_TYPE, { enumerable: false, value: this });
1005
+ if (value !== undefined)
1006
+ (0, runtime_3.reflectionMergePartial)(this, message, value);
1007
+ return message;
1008
+ }
1009
+ internalBinaryRead(reader, length, options, target) {
1010
+ let message = target ?? this.create(), end = reader.pos + length;
1011
+ while (reader.pos < end) {
1012
+ let [fieldNo, wireType] = reader.tag();
1013
+ switch (fieldNo) {
1014
+ case /* repeated pb.Project projects */ 1:
1015
+ message.projects.push(exports.Project.internalBinaryRead(reader, reader.uint32(), options));
1016
+ break;
1017
+ default:
1018
+ let u = options.readUnknownField;
1019
+ if (u === "throw")
1020
+ throw new globalThis.Error(`Unknown field ${fieldNo} (wire type ${wireType}) for ${this.typeName}`);
1021
+ let d = reader.skip(wireType);
1022
+ if (u !== false)
1023
+ (u === true ? runtime_2.UnknownFieldHandler.onRead : u)(this.typeName, message, fieldNo, wireType, d);
1024
+ }
1025
+ }
1026
+ return message;
1027
+ }
1028
+ internalBinaryWrite(message, writer, options) {
1029
+ /* repeated pb.Project projects = 1; */
1030
+ for (let i = 0; i < message.projects.length; i++)
1031
+ exports.Project.internalBinaryWrite(message.projects[i], writer.tag(1, runtime_1.WireType.LengthDelimited).fork(), options).join();
1032
+ let u = options.writeUnknownFields;
1033
+ if (u !== false)
1034
+ (u == true ? runtime_2.UnknownFieldHandler.onWrite : u)(this.typeName, message, writer);
1035
+ return writer;
1036
+ }
1037
+ }
1038
+ /**
1039
+ * @generated MessageType for protobuf message pb.ResetRequest
1040
+ */
1041
+ exports.ResetRequest = new ResetRequest$Type();
1042
+ // @generated message type with reflection information, may provide speed optimized methods
1043
+ class ResetResponse$Type extends runtime_5.MessageType {
1044
+ constructor() {
1045
+ super("pb.ResetResponse", []);
1046
+ }
1047
+ create(value) {
1048
+ const message = {};
1049
+ globalThis.Object.defineProperty(message, runtime_4.MESSAGE_TYPE, { enumerable: false, value: this });
1050
+ if (value !== undefined)
1051
+ (0, runtime_3.reflectionMergePartial)(this, message, value);
1052
+ return message;
1053
+ }
1054
+ internalBinaryRead(reader, length, options, target) {
1055
+ return target ?? this.create();
1056
+ }
1057
+ internalBinaryWrite(message, writer, options) {
1058
+ let u = options.writeUnknownFields;
1059
+ if (u !== false)
1060
+ (u == true ? runtime_2.UnknownFieldHandler.onWrite : u)(this.typeName, message, writer);
1061
+ return writer;
1062
+ }
1063
+ }
1064
+ /**
1065
+ * @generated MessageType for protobuf message pb.ResetResponse
1066
+ */
1067
+ exports.ResetResponse = new ResetResponse$Type();
1068
+ /**
1069
+ * @generated ServiceType for protobuf service pb.Fs
1070
+ */
1071
+ exports.Fs = new runtime_rpc_1.ServiceType("pb.Fs", [
1072
+ { name: "NewProject", options: {}, I: exports.NewProjectRequest, O: exports.NewProjectResponse },
1073
+ { name: "DeleteProject", options: {}, I: exports.DeleteProjectRequest, O: exports.DeleteProjectResponse },
1074
+ { name: "ListProjects", options: {}, I: exports.ListProjectsRequest, O: exports.ListProjectsResponse },
1075
+ { name: "Get", serverStreaming: true, options: {}, I: exports.GetRequest, O: exports.GetResponse },
1076
+ { name: "GetCompress", serverStreaming: true, options: {}, I: exports.GetCompressRequest, O: exports.GetCompressResponse },
1077
+ { name: "Update", clientStreaming: true, options: {}, I: exports.UpdateRequest, O: exports.UpdateResponse },
1078
+ { name: "Inspect", options: {}, I: exports.InspectRequest, O: exports.InspectResponse },
1079
+ { name: "Snapshot", options: {}, I: exports.SnapshotRequest, O: exports.SnapshotResponse },
1080
+ { name: "Reset", options: {}, I: exports.ResetRequest, O: exports.ResetResponse }
1081
+ ]);
1082
+ //# sourceMappingURL=fs_pb.js.map