@floless/app 0.169.0 → 0.171.0
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/dist/floless-server.cjs +65531 -43728
- package/dist/schemas/drawing-check.profile.v1.schema.json +12 -2
- package/dist/schemas/steel.model.v2.schema.json +196 -4
- package/dist/skills/floless-app-bridge/SKILL.md +3 -3
- package/dist/skills/floless-app-knowledge/SKILL.md +46 -15
- package/dist/skills/floless-app-new-workflow/SKILL.md +8 -1
- package/dist/skills/floless-app-onboarding/SKILL.md +5 -4
- package/dist/skills/floless-app-onboarding/references/floless-surfaces.md +0 -3
- package/dist/skills/floless-app-queue/SKILL.md +2 -3
- package/dist/skills/floless-app-report-issue/SKILL.md +2 -2
- package/dist/skills/floless-app-routines/SKILL.md +2 -2
- package/dist/skills/floless-app-routines/references/routines-api.md +20 -8
- package/dist/skills/floless-app-steel-model/SKILL.md +42 -39
- package/dist/skills/floless-app-steel-model/references/custom-connections.md +47 -0
- package/dist/skills/floless-app-steel-model/references/custom-sections.md +32 -0
- package/dist/skills/floless-app-steel-takeoff/SKILL.md +31 -1
- package/dist/skills/floless-app-ui/SKILL.md +71 -126
- package/dist/skills/floless-app-workflows/SKILL.md +22 -3
- package/dist/skills/floless-app-workflows/references/agent-steps.md +40 -6
- package/dist/skills/floless-app-workflows/references/exec-contract.md +27 -0
- package/dist/skills/floless-app-workflows/references/script-runner.md +105 -0
- package/dist/web/add-ons.js +407 -0
- package/dist/web/agent-steps.js +89 -18
- package/dist/web/agents.js +32 -22
- package/dist/web/analytics.js +1 -1
- package/dist/web/app.css +331 -190
- package/dist/web/app.js +33 -13
- package/dist/web/aware.js +926 -218
- package/dist/web/chat.css +6 -1
- package/dist/web/chat.js +316 -112
- package/dist/web/checkpoint-standard.js +5 -3
- package/dist/web/commands-drawing-check.js +1 -0
- package/dist/web/commands-filter.js +23 -0
- package/dist/web/commands-shell.js +479 -78
- package/dist/web/commands-steel.js +69 -2
- package/dist/web/commands-tekla-parser.js +23 -0
- package/dist/web/connections.js +14 -3
- package/dist/web/drawing-check-editor.js +352 -88
- package/dist/web/failure-copy.js +33 -2
- package/dist/web/filter-ai-proposal.js +11 -8
- package/dist/web/flo-3d.js +1 -1
- package/dist/web/guide.js +36 -29
- package/dist/web/index.html +98 -57
- package/dist/web/instructor.js +101 -17
- package/dist/web/kb-categories.js +64 -7
- package/dist/web/left-pane.js +4 -1
- package/dist/web/local-discovery.js +8 -7
- package/dist/web/missed-routines.js +239 -0
- package/dist/web/model-change-findings.js +430 -0
- package/dist/web/model-change-review.js +414 -0
- package/dist/web/model-editor-steel-adapter.js +2 -2
- package/dist/web/model-measure.js +6 -0
- package/dist/web/model-spatial-panel.js +19 -4
- package/dist/web/model-spatial-tools.js +3 -3
- package/dist/web/model-viewport-revit-adapter.js +3 -3
- package/dist/web/origin-rule.js +155 -0
- package/dist/web/project-access.js +1 -1
- package/dist/web/project-history.js +7 -1
- package/dist/web/project-modules.js +2 -2
- package/dist/web/project-rfis.js +6 -1
- package/dist/web/project-workflows.js +2 -2
- package/dist/web/revit-editor.css +85 -0
- package/dist/web/revit-editor.js +58 -9
- package/dist/web/run-history.js +12 -1
- package/dist/web/sha256-sync.js +62 -0
- package/dist/web/steel-3d-core.js +46 -9
- package/dist/web/steel-3d-flo.js +153 -7
- package/dist/web/steel-3d-view.js +33 -5
- package/dist/web/steel-ai-marks.js +3 -1
- package/dist/web/steel-custom-connection.js +161 -0
- package/dist/web/steel-custom-sections.js +1796 -0
- package/dist/web/steel-editor.html +732 -161
- package/dist/web/steel-environments.js +297 -0
- package/dist/web/steel-filter-usage.js +299 -0
- package/dist/web/steel-filter.html +104 -6
- package/dist/web/steel-model-v2-client-validation.js +11 -1
- package/dist/web/steel-model-v2-commands.js +116 -13
- package/dist/web/steel-model-v2-projection.js +1 -1
- package/dist/web/steel-read-confidence.js +1 -56
- package/dist/web/step-rename.js +3 -2
- package/dist/web/tekla-editor.html +1 -0
- package/dist/web/terminal-requests.js +1 -1
- package/dist/web/tool-updates.js +7 -6
- package/dist/web/workspaces.js +1968 -138
- package/launch.mjs +87 -9
- package/package.json +4 -1
- package/dist/web/panels.js +0 -831
|
@@ -2,7 +2,7 @@
|
|
|
2
2
|
name: floless-app-routines
|
|
3
3
|
description: This skill should be used when the user wants to set up a floless.app workflow (.flo app) to run automatically — "routines" — either on a timer (schedule) or on a live event (trigger). Triggers on requests like "schedule my BOM workflow every weekday at 7am", "run this workflow every 2 hours", "run my BOM whenever the Tekla model changes", "watch the model and run X on each change", "set up a trigger routine", "list my routines", "disable the morning routine", "delete that routine". Covers the floless.app routines REST API (create / list / edit / enable-disable / delete / run-now), the schedule presets, the event-trigger kind, the confirm-first rule, and the runnable gate.
|
|
4
4
|
metadata:
|
|
5
|
-
version: 0.1.
|
|
5
|
+
version: 0.1.12
|
|
6
6
|
---
|
|
7
7
|
|
|
8
8
|
# Setting up floless.app routines (automatic .flo runs)
|
|
@@ -162,7 +162,7 @@ curl -s -X DELETE http://127.0.0.1:4317/api/routines/<id>
|
|
|
162
162
|
current `activePublication.runtimeAppId`; the routine follows every later publish on its own — never
|
|
163
163
|
delete and recreate a routine after publishing.
|
|
164
164
|
- **Run-now is schedule-only.** `routines.run` (`POST /api/routines/:id/run`) on a trigger returns **400**
|
|
165
|
-
("
|
|
165
|
+
("This routine runs by itself whenever its event happens, so it has no Run now. Turn it on or off instead."). Don't offer run-now for a
|
|
166
166
|
trigger; the control is the enable/disable toggle (start/stop the live watcher).
|
|
167
167
|
- **Run-now while that routine is already queued or running is a 409, not a second run.** The
|
|
168
168
|
envelope comes back `ok: false` — nothing was started. Tell the user it is already running (or
|
|
@@ -121,26 +121,38 @@ Supporting reads (same server):
|
|
|
121
121
|
|
|
122
122
|
- `400` — validation: missing name, unknown/invalid workflow id, malformed schedule
|
|
123
123
|
(bad `HH:MM`, empty weekly `days`, `everyHours` not a divisor of 24); a `kind:"trigger"` create
|
|
124
|
-
on a workflow that is **not trigger-eligible** (`{ "error": "workflow
|
|
125
|
-
or `POST /:id/run` on a **trigger** (`{ "error": "
|
|
124
|
+
on a workflow that is **not trigger-eligible** (`{ "error": "That workflow does not start by watching for changes …" }`);
|
|
125
|
+
or `POST /:id/run` on a **trigger** (`{ "error": "This routine runs by itself whenever its event happens, so it has no Run now. …" }`).
|
|
126
|
+
A refusal that carries `"refusal": "routine"` has an `error` FloLess wrote for the person: relay it as it
|
|
127
|
+
is. (The already-running 409 below has no marker; read it by its `running` flag.)
|
|
126
128
|
- `402` — no valid subscription (the app must be signed in).
|
|
127
129
|
- `404` — no routine with that id.
|
|
128
|
-
- `409` — **different refusals; tell them apart by the `running` flag
|
|
129
|
-
- On `POST /api/routines` (create): `{ "error": "
|
|
130
|
+
- `409` — **different refusals; tell them apart by the route and the `running` flag, never by the status alone.**
|
|
131
|
+
- On `POST /api/routines` (create): `{ "error": "You already have 15 routines, the most FloLess keeps. …", "refusal": "routine" }` —
|
|
130
132
|
the cap (both kinds share it). Relay it and offer to delete an existing routine.
|
|
131
133
|
- On `POST /:id/run`: `{ "running": true, "error": "this routine is already running or waiting its
|
|
132
134
|
turn" }` — that routine is already queued or mid-run and **nothing was started**. Say it is
|
|
133
135
|
already running or waiting; do NOT relay a cap message and do NOT offer to delete anything.
|
|
134
136
|
Retrying is pointless until that fire completes.
|
|
135
|
-
- On `POST /api/routines` (create), rarely: `{ "error": "
|
|
136
|
-
|
|
137
|
+
- On `POST /api/routines` (create), rarely: `{ "error": "That copy of the workflow is not the one currently in
|
|
138
|
+
use; a newer one has replaced it. …", "refusal": "routine" }` — a FloLess-owned workflow was published again while the routine was being created.
|
|
137
139
|
Retry the same request; the server resolves the current publication.
|
|
138
140
|
|
|
139
141
|
## Notes on behavior (so expectations are right)
|
|
140
142
|
|
|
141
143
|
- **Local time, DST-safe.** Schedules are wall-clock local; 07:00 stays 07:00 across a DST change.
|
|
142
|
-
- **Missed fires skip forward.** If
|
|
143
|
-
future occurrence (no catch-up burst on boot).
|
|
144
|
+
- **Missed fires skip forward, and FloLess asks once.** If FloLess was closed at fire time, the next
|
|
145
|
+
fire is the next future occurrence: nothing runs on its own (no catch-up burst on boot). The
|
|
146
|
+
routine's history gets one `skipped` row with a `missed` count, and the routine gets ONE open
|
|
147
|
+
question, `missedOffer` (`{ id, first, last, count, atLeast?, starting? }`), however many times it
|
|
148
|
+
was missed. The person answers it on a card in FloLess: Run now (`POST /:id/run` with
|
|
149
|
+
`{ "missedOfferId": "<id>" }`, which runs it once) or Skip (`POST /:id/missed-offer/skip` with
|
|
150
|
+
`{ "expectedOfferId": "<id>" }`, which records "Skipped by you"). Either answer for a question that
|
|
151
|
+
was already answered, closed or replaced is `409 { code: "no-missed-offer" }`, and nothing runs. The
|
|
152
|
+
routine's next scheduled fire, switching it off, giving it new times or pausing its agent closes the
|
|
153
|
+
question without a row. Never answer it for the person: a run can change a model or use their AI
|
|
154
|
+
subscription, so it is their choice. Ask them, then use the chat's `routines.run` (always a card) or
|
|
155
|
+
`routines.skip-missed` (a change like any other edit: a card unless the chat may make changes).
|
|
144
156
|
- **Serialized, and one run per routine.** Scheduled runs share the single active-run lock with
|
|
145
157
|
manual ▶ Run, so a fire that coincides with a run of a DIFFERENT workflow waits its turn (the host
|
|
146
158
|
bridge does one exec at a time). A fire for a routine that is already queued or mid-run is
|
|
@@ -2,7 +2,7 @@
|
|
|
2
2
|
name: floless-app-steel-model
|
|
3
3
|
description: The front-door guide for turning a structural steel drawing set into an editable native steel.model/v2 model in floless.app. It orchestrates project setup, set knowledge, AWARE detailer agents, Drawing Filter review, registered plan views, model reading, connection detailing, clash checks, and exports. Use for asks such as "model this steel job from the drawings", "take off this whole set", "start a steel model project", or "/floless-app-steel-model". It is re-runnable and preserves the Filter → Save → read → review → History process end to end.
|
|
4
4
|
metadata:
|
|
5
|
-
version: 0.
|
|
5
|
+
version: 0.31.0
|
|
6
6
|
---
|
|
7
7
|
|
|
8
8
|
# Steel Model — guide a steel drawing set into an editable model
|
|
@@ -16,15 +16,14 @@ classify the sheets → read each framing plan into an editable **steel.model/v2
|
|
|
16
16
|
point the user at the on-canvas tools (filter, 3D, IFC/Tekla export, BOM, the connection library,
|
|
17
17
|
clickable callouts).
|
|
18
18
|
|
|
19
|
-
It is the **orchestration layer ABOVE** the readers and the editor. The
|
|
20
|
-
done by **`floless-app-steel-takeoff`** (the Steel Takeoff reader) — this guide
|
|
21
|
-
|
|
19
|
+
It is the **orchestration layer ABOVE** the readers and the editor. The drawing reading is
|
|
20
|
+
done by **`floless-app-steel-takeoff`** (the Steel Takeoff reader) — this guide makes that read
|
|
21
|
+
reliable, then hands off. The host AI is the brain (the FloLess thin-UI
|
|
22
22
|
contract): reading happens at COMPOSE time with the terminal AI's own vision; there is no model in
|
|
23
23
|
the run path and no API key.
|
|
24
24
|
|
|
25
25
|
**Re-runnable + interactive.** Each stage ends with an explicit **confirm gate** — show the user
|
|
26
|
-
what was found and get an OK before
|
|
27
|
-
re-invoke ("we already set up the folder, provision the agents").
|
|
26
|
+
what was found and get an OK before the next stage. Resume at any stage on re-invoke.
|
|
28
27
|
|
|
29
28
|
> Companion skills (all ship with floless.app — invoke them, don't duplicate them):
|
|
30
29
|
> - **`reading-structural-drawings`** — the reading *discipline* (massing + coordinate frame FIRST,
|
|
@@ -32,7 +31,8 @@ re-invoke ("we already set up the folder, provision the agents").
|
|
|
32
31
|
> (stages 2 and 5) — it stops the classic failures (two buildings read as one, a sloped roof read
|
|
33
32
|
> as flat, grids conflated across sheets).
|
|
34
33
|
> - **`floless-app-steel-takeoff`** — reads one framing plan into the contract (the heavy vision
|
|
35
|
-
> pipeline, the filter pre-stage, the AISC/EN/BS lookup, the contract write + editor hand-off).
|
|
34
|
+
> pipeline, the filter pre-stage, the AISC/EN/BS lookup, the contract write + editor hand-off). A
|
|
35
|
+
> section no catalogue lists is a [custom section](references/custom-sections.md), never forced to the nearest catalogue size.
|
|
36
36
|
> - **`steel-drawing-abbreviations`** — the default US/AISC abbreviations + shape-designation legend.
|
|
37
37
|
> The fallback for note/profile codes (TYP, TOS, UON, `(E)`/`(N)`, HSS, WT) when the set omits its
|
|
38
38
|
> own abbreviations sheet (stage 2).
|
|
@@ -134,10 +134,11 @@ In a Quick read:
|
|
|
134
134
|
- **Stage 6:** a brace `memberType` the drawings do not state is decided, not asked (default `brace`),
|
|
135
135
|
and recorded as an `audit-gap` decision naming the member. A missing schedule sheet is decided too:
|
|
136
136
|
build from what the set shows and record what is missing.
|
|
137
|
-
- **Stage 7:** a detail no available connection type models is
|
|
138
|
-
`{ channel: "unmodelled-detail", sheetId, detailRef }
|
|
139
|
-
|
|
140
|
-
|
|
137
|
+
- **Stage 7:** a detail no available connection type models is built as a custom connection (c) and
|
|
138
|
+
recorded as `{ channel: "unmodelled-detail", sheetId, detailRef }`, exactly as
|
|
139
|
+
[custom connections](references/custom-connections.md) says; without a clean fit it is (a) "left
|
|
140
|
+
unbuilt but recorded". **Never pass `acceptFailedFit` in a Quick read.** (b) a named approximation only
|
|
141
|
+
when the drawings make the approximation obvious, and the decision says so. A connection assumption you would have proposed to the person is
|
|
141
142
|
`{ channel: "connection", jointId, covers }`: never written into the connection assumptions, which are
|
|
142
143
|
the person's.
|
|
143
144
|
- **What stays the person's:** the Drawing Filter Save, unless the read's instruction lets you choose it:
|
|
@@ -224,10 +225,13 @@ The reader leans on a **region-specific steel detailer** agent (AISC vs EN vs BS
|
|
|
224
225
|
if the user will bake later, the host bridges.
|
|
225
226
|
|
|
226
227
|
1. **Check what's installed:** `aware agent list --json`.
|
|
227
|
-
2. **Steel detailer —
|
|
228
|
-
|
|
229
|
-
`
|
|
230
|
-
(
|
|
228
|
+
2. **Steel detailer — install the one that matches the project's standard.** The project already states it
|
|
229
|
+
(`US`, `UK` or `EU`, chosen when the project was created and fixed for its life; read it from the project, do not
|
|
230
|
+
ask the user again): `US` -> `steel-detailer-us` (AISC / imperial), `UK` -> `steel-detailer-uk` (BS EN), `EU` ->
|
|
231
|
+
`steel-detailer-eu` (EN, metric). FloLess's own list of standards names the agent for each (the `detailerAgent` of
|
|
232
|
+
the project's environment), so use that rather than a region you inferred. Ask only when the project states no
|
|
233
|
+
standard. Install with `aware agent install <id>`. **Verify it's live** with a known-section lookup before relying
|
|
234
|
+
on it (a section that should resolve — a W-shape for US, a `UKB` for UK, an `HEA140` for EU — returns a weight).
|
|
231
235
|
3. **Bake targets (optional, only if they'll export later):** offer `tekla`, `rhino`, `revit`,
|
|
232
236
|
`sketchup` — install the ones they want. (3D and IFC export need no host; Tekla bake needs Tekla
|
|
233
237
|
open with a model.)
|
|
@@ -411,10 +415,17 @@ member is supported and which is supporting. Ask, per detail:
|
|
|
411
415
|
- **What does the detail dimension that the type cannot hold?** A work-point drop, a plate that follows the
|
|
412
416
|
supporting member's depth, a fabrication note. Anything unexpressible must be recorded, not dropped.
|
|
413
417
|
|
|
414
|
-
**If no available type matches, do not force one
|
|
418
|
+
**If no available type matches, do not force one.** A connection forced into the wrong type looks
|
|
415
419
|
plausible in the model, passes every dimensional check, and is worse than an absent one because nobody
|
|
416
420
|
knows to question it. An unmodelled detail does not hold back the model either: the members are modelled
|
|
417
|
-
and published either way
|
|
421
|
+
and published either way.
|
|
422
|
+
|
|
423
|
+
**(c) Build it as a custom connection. This is the default.** Compose a `steel.connection/v1` definition
|
|
424
|
+
from the standard parts, anchored to the members' faces. Every drawn number is pinned; fill only
|
|
425
|
+
rule-governed minimums, never a value that sets its shape or size. Check it with
|
|
426
|
+
`steel.check-connection-definition`, then apply only a clean fit. Keeping a failed fit is the person's
|
|
427
|
+
choice alone, and sign-off is theirs. Follow [custom connections](references/custom-connections.md) step by
|
|
428
|
+
step. **When (c) cannot be built, ask.** The ask:
|
|
418
429
|
|
|
419
430
|
- **names the detail as a detailer would**, such as "the brace gusset in 7/S5.2", never a marker id alone;
|
|
420
431
|
- **says where it is**: the sheet, the grid reference, the callout tag, and the members it joins;
|
|
@@ -422,7 +433,8 @@ and published either way, and the detail becomes a question the user can answer
|
|
|
422
433
|
welded to the beam's web between its flanges, and the brace-gusset type only welds at a beam's flange
|
|
423
434
|
tips");
|
|
424
435
|
- **offers the choices, with a default:**
|
|
425
|
-
- **(a) Leave that connection unbuilt but recorded
|
|
436
|
+
- **(a) Leave that connection unbuilt but recorded.** This is the fallback when (c) is missing a shape or
|
|
437
|
+
size value or its fit is not met, and the default of this question. Record the detail as read,
|
|
426
438
|
with the members it joins, and build nothing from it. If the user cannot answer the question, file
|
|
427
439
|
it as an RFI where `floless-app-rfi` allows it; otherwise keep it open in the chat. In a drawing
|
|
428
440
|
read, the carrier is the detail marker's `candidateDispositions` row of `unresolved`, and its
|
|
@@ -452,10 +464,9 @@ and published either way, and the detail becomes a question the user can answer
|
|
|
452
464
|
*fit* are two different questions, and passing the first tells you nothing about the second. Ask both,
|
|
453
465
|
on every detail you build — not once at the end.
|
|
454
466
|
|
|
455
|
-
The failure this exists to stop: a gusset
|
|
456
|
-
|
|
457
|
-
|
|
458
|
-
from a grip that counted only the plate. Every number checked out. Nothing touched.
|
|
467
|
+
The failure this exists to stop: a gusset matched every drawn dimension exactly while the plate ran
|
|
468
|
+
**through** the angle leg, the nut floated inside the member, and the bolt was sized from a grip that
|
|
469
|
+
counted only the plate.
|
|
459
470
|
|
|
460
471
|
**After building a connection, verify each of these — numerically, in world coordinates:**
|
|
461
472
|
|
|
@@ -487,13 +498,11 @@ plate bears on and prove the plate is on it:
|
|
|
487
498
|
|
|
488
499
|
**Do BOTH — measure it AND look at it. They catch different failures.**
|
|
489
500
|
|
|
490
|
-
- **Measure** what the eye cannot see: a few millimetres of overlap is invisible
|
|
491
|
-
|
|
492
|
-
- **Look** at what the numbers do not flag: **zoom in on the built connection every time**. A
|
|
493
|
-
|
|
494
|
-
|
|
495
|
-
the instant you see it. Gross proportion and placement errors are found by eye in one second and can
|
|
496
|
-
survive every numeric check you write.
|
|
501
|
+
- **Measure** what the eye cannot see: a few millimetres of overlap is invisible, so contact, grip and
|
|
502
|
+
bearing are computed, never judged from a picture.
|
|
503
|
+
- **Look** at what the numbers do not flag: **zoom in on the built connection every time**. A 15" plate on
|
|
504
|
+
a 4" angle reads as "plate depth 15.0", correct against its drawing, and is obviously wrong the instant
|
|
505
|
+
you see it.
|
|
497
506
|
|
|
498
507
|
Passing one is not passing the other. A connection is right when the numbers *and* the picture agree.
|
|
499
508
|
|
|
@@ -510,13 +519,9 @@ it lands on. Member ends are usually placed at WORK POINTS, which sit on the sup
|
|
|
510
519
|
inside it — so a member must be trimmed back to the support's actual face plus its erection gap, and that
|
|
511
520
|
distance grows with the skew of the crossing. Verify the trim, not just the joint.
|
|
512
521
|
|
|
513
|
-
**Count what you built against what you specified.** Every check above scores a connection that *exists
|
|
514
|
-
|
|
515
|
-
|
|
516
|
-
default — the first because there is no geometry to fault, the second because a fused part measures as one
|
|
517
|
-
correct-looking body. Both models open, render and export without complaint.
|
|
518
|
-
|
|
519
|
-
So reconcile the inventory each time you build, and treat two of the four outcomes as failures:
|
|
522
|
+
**Count what you built against what you specified.** Every check above scores a connection that *exists*,
|
|
523
|
+
so none sees a connection specified and never built, or two connections collapsed into one part. Reconcile
|
|
524
|
+
the inventory each time you build, and treat two of the four outcomes as failures:
|
|
520
525
|
|
|
521
526
|
- **FAIL — specified, never built.** Every row in `joints[]` — the PLACED connections, not the
|
|
522
527
|
`connections[]` library they cite — owns at least one part in the model. A row that produced nothing is
|
|
@@ -535,9 +540,7 @@ disagree about where a connection ends, both are wrong — and the disagreement
|
|
|
535
540
|
failure on a model that is actually fine, which is the fastest way to get the gate switched off.
|
|
536
541
|
|
|
537
542
|
**Say what this gate does not prove, every time you report it: it proves you built what you specified,
|
|
538
|
-
never that you specified enough.**
|
|
539
|
-
other one scores the dimensions of a connection that is already there. An inventory missing half the
|
|
540
|
-
details on the sheet passes all of them, and passes this one too.
|
|
543
|
+
never that you specified enough.** An inventory missing half the details on the sheet passes it.
|
|
541
544
|
|
|
542
545
|
**Where this class of bug hides: nominal-vs-real section data.** A designation carries its thickness
|
|
543
546
|
(an angle's leg, a tube's wall) and that token is easy to drop on the way to geometry — leaving a guessed
|
|
@@ -0,0 +1,47 @@
|
|
|
1
|
+
# Custom connections (a detail no connection type models)
|
|
2
|
+
|
|
3
|
+
Stage 7 option (c), the default when no available connection type models a detail. A custom connection is
|
|
4
|
+
a `steel.connection/v1` definition: plates, bolt groups, welds, cuts and trims, each anchored to a named
|
|
5
|
+
face of a member the connection is bound to, never placed in world coordinates. The engine expands it the
|
|
6
|
+
same way every time, and FloLess labels the result "AI-assisted connection". Work in this order:
|
|
7
|
+
|
|
8
|
+
1. **Compose the definition from the topology** you read in stage 7: which member's end the connection
|
|
9
|
+
sits at (the role with `end: true`), which faces bear, which plies each bolt group clamps (head side
|
|
10
|
+
first), which edges are welded. Every number the drawing states is a pinned param. Record where it came
|
|
11
|
+
from in `provenance` (`assisted: "ai"`, `source`, `evidence.sheetId`/`detailRef`).
|
|
12
|
+
2. **Fill only what a detailing rule governs**: the minimum weld leg for the thinner ply, the minimum edge
|
|
13
|
+
distance, the standard hole size and the bolt length from grip. Write them as the rule
|
|
14
|
+
(`minWeldLeg(...)`, `minEdge(...)`, `holeDia(...)`, `boltLength(...)`) or record the value in
|
|
15
|
+
`provenance.assumptions` with its `basis: "rule-minimum"` and its clause. **Never guess a value that
|
|
16
|
+
sets the connection's shape or size**: the plate outline, a thickness, the bolt count, the bolt
|
|
17
|
+
positions, or which faces bear. If the drawing lacks one, stop and fall back to the question (a),
|
|
18
|
+
naming the missing value, as a detailer would raise an RFI for an undimensioned plate.
|
|
19
|
+
3. **Run `steel.check-connection-definition`** with the definition and the member each role is bound to.
|
|
20
|
+
It builds the connection without saving anything and returns the parts, the rule values with their
|
|
21
|
+
clauses, every fit check and the expansion `identity`.
|
|
22
|
+
4. **Apply only a clean fit** with `steel.apply-connection-definition` (a card the person confirms). It
|
|
23
|
+
builds nothing while any fit check is not met.
|
|
24
|
+
5. **Otherwise fall back to (a)**, and name the failing check the way the check names it ("Parts clear of
|
|
25
|
+
each other and of the members: the gusset runs 4.8 mm into the angle leg"). Offer the person the choice
|
|
26
|
+
to keep it built anyway. **That choice is theirs alone.** Pass `acceptFailedFit` (each failing check
|
|
27
|
+
with the `identity` the check gave) only after they asked for it on that card. The connection is then
|
|
28
|
+
labelled "fit not met" everywhere it shows. Never mark a custom connection checked or reviewed.
|
|
29
|
+
Sign-off is the person's.
|
|
30
|
+
|
|
31
|
+
The signals of a forced fit in stage 7 apply to custom connections too, and stage 8 still applies in full.
|
|
32
|
+
The check measures the generic facts (bearing, head and nut bearing, grip, bolt length, edge distance, weld
|
|
33
|
+
line, clash), but you still read them and look at the result.
|
|
34
|
+
|
|
35
|
+
**The label.** The person can turn the "AI-assisted connection" label off for one connection or the whole
|
|
36
|
+
model (`steel.set-ai-assisted-label`). That hides only the visible label: FloLess's record and the export's
|
|
37
|
+
`meta.provenance` keep the fact. Never turn it off for them unasked.
|
|
38
|
+
|
|
39
|
+
## In a Quick read
|
|
40
|
+
|
|
41
|
+
Build it the same way and record `{ channel: "unmodelled-detail", sheetId, detailRef }` with `chosen`
|
|
42
|
+
"built as a custom connection" and `value: { jointId, defId, version, identity, fit: [] }` from the check
|
|
43
|
+
and the apply. Each rule-minimum value you filled is also a `{ channel: "connection", jointId, covers }`
|
|
44
|
+
decision naming its clause. When a shape or size value is missing, or the fit check fails, nothing is
|
|
45
|
+
built: record the decision with option (a) "left unbuilt but recorded", leave `jointId` out of `value` and
|
|
46
|
+
list the failing check ids in `fit`. **Never pass `acceptFailedFit` in a Quick read**: keeping a failed fit
|
|
47
|
+
built is only the person's choice, in Make precise.
|
|
@@ -0,0 +1,32 @@
|
|
|
1
|
+
# Custom sections (a section no catalogue lists)
|
|
2
|
+
|
|
3
|
+
When a drawing calls for a section that no catalogue row describes — a welded plate girder, a built-up
|
|
4
|
+
I of stated plates, a tapered plate — make it a **custom section** instead of forcing the nearest
|
|
5
|
+
catalogue size (a near size is dimensionally wrong, and every weight and export built on it is too).
|
|
6
|
+
|
|
7
|
+
- **Evaluate first, then place.** `steel.evaluate-custom-section` takes a definition
|
|
8
|
+
(`{kind: "floless.section-profile", kindVersion: 1, id: "<add-on-id>/<name>@1", payload}`) and the
|
|
9
|
+
parameter values in mm, and answers the evaluated outline, area, mass per metre with its density basis,
|
|
10
|
+
and whether an IFC file can carry the shape. It writes nothing; show the person the section and the
|
|
11
|
+
numbers. Then `steel.place-custom-section` puts it on the members in ONE save (give the model tag from
|
|
12
|
+
`steel.read-model`). The payload lists `parameters` (name, label, `unit: "mm"`, optional min/max),
|
|
13
|
+
an `outline` of corner formulas (numbers, parameter names, `+ - * /`, brackets, `min`, `max`), an
|
|
14
|
+
optional `designation` template such as `"WI{d}x{bf}"`, and, for an I, `export.canonical`
|
|
15
|
+
`{shape: "i", d, bf, tw, tf}` so IFC carries it as a real I-section.
|
|
16
|
+
- **Ids never change meaning.** A definition id is bound to its content. A different definition under an
|
|
17
|
+
id the model already uses is refused with the next free id to use (`…@2`): use that; never reuse the id.
|
|
18
|
+
- **The section is the member's, not its name.** Two sections may share a designation; FloLess keys
|
|
19
|
+
every bill, group and merge on the section itself and labels the two apart. Typing a catalogue profile
|
|
20
|
+
over a custom member takes it off the custom section.
|
|
21
|
+
- **Mass is area × density**, from the member's material: structural steel 7850 kg/m³, stainless 8000,
|
|
22
|
+
aluminium 2700. An unrecognised material is weighed as steel and said to be an assumption.
|
|
23
|
+
- **A section FloLess cannot check is never swapped.** One made by a newer FloLess (an unknown kind or
|
|
24
|
+
version), or whose stored shape no longer matches its recipe, is drawn as a labelled placeholder and
|
|
25
|
+
left out of quantities and exports. Say so, and offer the two ways forward: fix the definition, or the
|
|
26
|
+
person proceeds on the stored shape as an assumption (`steel.custom-section-assumption`, which they
|
|
27
|
+
choose — the export and bill then name it as an assumption).
|
|
28
|
+
- **IFC.** A custom I goes out as a real I-section with its own dimensions. A shape IFC has no section
|
|
29
|
+
for asks first: leave those members out, or send each as its bounding box, named in the file as an
|
|
30
|
+
assumption. Ask the person; pass their choice and the question's key back to `steel.export-ifc`.
|
|
31
|
+
- **Connections on a custom section are not modelled yet.** A connection naming one is reported as not
|
|
32
|
+
built; say so rather than claiming it fits, and check clash and placement by hand as stages 7-8 require.
|
|
@@ -7,7 +7,7 @@ description: >-
|
|
|
7
7
|
two-phase Drawing Filter process: first prepare and save the deterministic Filter, then read only the
|
|
8
8
|
selected evidence into model-global members, registered plan views, observations, and revision history.
|
|
9
9
|
metadata:
|
|
10
|
-
version: 0.
|
|
10
|
+
version: 0.100.0
|
|
11
11
|
---
|
|
12
12
|
|
|
13
13
|
## Shared height study: server-owned reader claims
|
|
@@ -733,6 +733,15 @@ In a Quick read:
|
|
|
733
733
|
| ask the bubble-token question | `{ channel: "audit-gap", gapKind: "bubble-token", fields: { sheet } }` with the reading the sheet supports |
|
|
734
734
|
| talk through the audit questions, offer or file an RFI | **settle every question you can first**: look again (the sheets it names, sections, schedules, notes, the page pictures), decide the answer the drawings support, repair the model to match, and record `{ channel: "audit-gap", gapKind: <row kind>, fields: { rfiId: <row id> } }` with `answers: { generation: <questionsGeneration>, rfiId: <row id> }` and the question in your own words (at most 600 characters); then audit again. A height is the exception: settle it with the height decision above, never by writing `z`; on a member already in the published model it is proposed in the review as the AI's change, so count it as settled by the AI and proposed for review, not as open. An RFI is the last step, never a way to hand work back: only a question you genuinely cannot settle after trying is filed, and those must be as few as possible. File it in the submit's `rfiSelection.gaps`, see "Submit a Quick read" below |
|
|
735
735
|
|
|
736
|
+
- **The model origin** follows the bottom-left rule: the crossing of the first X and first Y straight
|
|
737
|
+
grid lines (lowest in world order) that both reach, when every plan view is upright; otherwise choose
|
|
738
|
+
with a reason. Another crossing is allowed; say why. The audit and the model label it against the
|
|
739
|
+
default, and never block it. **When the person chose in the New project dialog to pick it themself**
|
|
740
|
+
(the instruction says so), the origin is theirs: record no origin decision, ask the origin row alone on
|
|
741
|
+
the setup card (any other row answers `quick-read-decides`), propose the bottom-left, and keep doing the
|
|
742
|
+
work that does not rest on it. Author what they confirm. A row whose status is `handed-to-ai` is theirs
|
|
743
|
+
handed back: decide it by the rule and record it. While it is open, write `"grid": {}` in the shell, and
|
|
744
|
+
end the run as `needs-you` if nothing else is left.
|
|
736
745
|
- **Submit a Quick read.** Every audit response carries `questionsGeneration`: name it in every decision
|
|
737
746
|
and every RFI, and the server binds each to the facts that audit listed. Every submit, first read and
|
|
738
747
|
re-read alike, carries `rfiSelection: { requestId, gaps: [ ... ] }` with one singleton per question you
|
|
@@ -1011,6 +1020,9 @@ rows to the same setup flow only after that study; do not ask them early merely
|
|
|
1011
1020
|
grid axes (the ids you write, the labels the person sees). A point on a skewed or partial line
|
|
1012
1021
|
(`K.1/1.1`) goes under `offGrid`, naming the straight choice it is the same point as and why. The
|
|
1013
1022
|
card states that equivalent before the person can confirm, and what lands is the straight point.
|
|
1023
|
+
Set `proposed` to the bottom-left crossing: the first X and first Y straight grid lines (lowest in
|
|
1024
|
+
world order) that both reach, when every plan view is upright. With a rotated view or no straight
|
|
1025
|
+
grid there is no default; propose with a reason, or not at all.
|
|
1014
1026
|
- **level**, per plan VIEW: `{ kind: "level", viewId, page, title, readings?: [...], noSingleLevel?:
|
|
1015
1027
|
{ why } }`. `readings` are exactly the plan-elevation-proposal readings (step 9 below). A sheet
|
|
1016
1028
|
with two plan views (an enlarged stair foundation plan and its second-floor plan) gets TWO rows. A
|
|
@@ -1187,6 +1199,9 @@ because nothing automatic can tell a genuine dimension chain apart from a coinci
|
|
|
1187
1199
|
of a neighbouring row of dimensions. **A metric sheet never reaches `author`, however strong the
|
|
1188
1200
|
recorded analysis.**
|
|
1189
1201
|
|
|
1202
|
+
On a **metric** `printed-unverified` row no grid family could be built, so no dimension checked the printed
|
|
1203
|
+
`1:N`; it assumes a 100 % plot. Say "from the printed ratio alone, unchecked", never measured or fitted.
|
|
1204
|
+
|
|
1190
1205
|
On a `metric-unverified` row, quote `outcome.standard`, `outcome.unit` (whether the sheet's bare
|
|
1191
1206
|
numbers were read as millimetres or centimetres - real sets use either, and the difference is a factor
|
|
1192
1207
|
of ten), and `outcome.plottedAtPct` (how far the drawn content sits from that ratio: a real metric
|
|
@@ -1375,6 +1390,21 @@ Two rules follow, and both matter:
|
|
|
1375
1390
|
wrong, and invisible to any check that only compares sizes. If you cannot tell whether the section
|
|
1376
1391
|
is turned, that is an RFI, not a default.
|
|
1377
1392
|
|
|
1393
|
+
**A European (`EU`) project: write the designation as drawn; FloLess resolves it.** `HEA140`, `IPE400`, `UPE100`
|
|
1394
|
+
match the catalogue as written. `RHS200*100*5`, `SHS80*3` and `L100*8` resolve to `KK200/100/5`, `KK80/3` and `L100/8`
|
|
1395
|
+
(`x`, `×` and `*` are the same). A hollow section with TWO numbers is SQUARE: `RHS100*4` is 100 by 100 by 4.
|
|
1396
|
+
- **`RHS`/`SHS` is an assumption FloLess labels** ("assumed cold-formed EN 10219 - the drawing does not say") on the
|
|
1397
|
+
member and the bill. Never hide the label and never pick `KW` to be safe.
|
|
1398
|
+
- **When the drawing states the route** (a note says hot-finished, EN 10210), write the exact name (`KW200/100/5`) as
|
|
1399
|
+
`profile` and the evidence in the member's `profileBasis`, in plain English, naming the sheet or note. If the note's
|
|
1400
|
+
reach is unclear, keep the drawn spelling and ask. When you change a member's `profile`, restate or remove its `profileBasis`.
|
|
1401
|
+
- The catalogue also holds the sizes the Dutch export lacks, from the Tekla default environment: EN 10219/10210 walls
|
|
1402
|
+
such as 2.5, 7.1 and 8.8 mm, small `CHS`, `HD` columns and `USP` channels. Their own names (`CFRHS120X80X7.1`,
|
|
1403
|
+
`CFCHS48.3X2.5`, `HD400*237`) are catalogue names, so write them as drawn too; `RHS`/`SHS` still lands on the
|
|
1404
|
+
cold-formed row and is still labelled.
|
|
1405
|
+
- A size the catalogue deliberately lacks (`RHS160*100*4`) stays unresolved and raises an RFI; never use the nearest size.
|
|
1406
|
+
- Default grade is `S355` (open) and `S355J2H` (hollow), a labelled default; the drawing's material list governs. Scale `1:50` is `mm_per_px = 50 x 25.4/72`.
|
|
1407
|
+
|
|
1378
1408
|
**A mark may legitimately serve several runs, and the geometry cannot tell you how many.** One mark
|
|
1379
1409
|
labelling a repeated bay, or qualified by a `TYP.` note, is correct; the same mark claimed by three
|
|
1380
1410
|
runs may equally be one member drawn twice. `TYP.` is a separate text element from the mark it
|