@enyo-energy/sunspec-sdk 1.6.0 → 1.8.0
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/dist/cjs/sunspec-battery-feature-calibrator.cjs +5 -3
- package/dist/cjs/sunspec-battery-feature-calibrator.d.cts +4 -1
- package/dist/cjs/sunspec-battery-grid-charge.cjs +32 -0
- package/dist/cjs/sunspec-battery-grid-charge.d.cts +9 -0
- package/dist/cjs/sunspec-battery-schedule-handler.cjs +6 -6
- package/dist/cjs/sunspec-battery-schedule-handler.d.cts +4 -1
- package/dist/cjs/sunspec-devices.cjs +38 -11
- package/dist/cjs/sunspec-devices.d.cts +15 -2
- package/dist/cjs/sunspec-interfaces.cjs +25 -1
- package/dist/cjs/sunspec-interfaces.d.cts +28 -0
- package/dist/cjs/sunspec-modbus-client.cjs +104 -22
- package/dist/cjs/sunspec-modbus-client.d.cts +18 -4
- package/dist/cjs/version.cjs +1 -1
- package/dist/cjs/version.d.cts +1 -1
- package/dist/sunspec-battery-feature-calibrator.d.ts +4 -1
- package/dist/sunspec-battery-feature-calibrator.js +6 -4
- package/dist/sunspec-battery-grid-charge.d.ts +9 -0
- package/dist/sunspec-battery-grid-charge.js +28 -0
- package/dist/sunspec-battery-schedule-handler.d.ts +4 -1
- package/dist/sunspec-battery-schedule-handler.js +7 -7
- package/dist/sunspec-devices.d.ts +15 -2
- package/dist/sunspec-devices.js +39 -12
- package/dist/sunspec-interfaces.d.ts +28 -0
- package/dist/sunspec-interfaces.js +24 -0
- package/dist/sunspec-modbus-client.d.ts +18 -4
- package/dist/sunspec-modbus-client.js +105 -23
- package/dist/version.d.ts +1 -1
- package/dist/version.js +1 -1
- package/package.json +2 -2
|
@@ -254,12 +254,21 @@ class SunspecModbusClient {
|
|
|
254
254
|
// announces itself twice — once by the transport, once by this client's own close/reopen —
|
|
255
255
|
// and an app must not be told to re-authenticate twice for one loss.
|
|
256
256
|
unitSessionReportedLost = new Set();
|
|
257
|
-
// Model 124 InOutWRte_RvrtTms written
|
|
258
|
-
// setBatteryRateRevertTimeoutSeconds().
|
|
257
|
+
// Model 124 InOutWRte_RvrtTms written when a battery connects and re-asserted by limit writes.
|
|
258
|
+
// See setBatteryRateRevertTimeoutSeconds().
|
|
259
259
|
batteryRateRevertTimeoutSeconds = sunspec_interfaces_js_1.DEFAULT_BATTERY_RATE_REVERT_TIMEOUT_SECONDS;
|
|
260
260
|
// Units whose InOutWRte_RvrtTms write has already failed and been warned about. Later
|
|
261
261
|
// failures on the same unit stay silent so a device without the register warns once.
|
|
262
262
|
batteryRateRevertWarnedUnits = new Set();
|
|
263
|
+
// When InOutWRte_RvrtTms was last written, per unit — failed attempts included, so a device
|
|
264
|
+
// that rejects the register is retried once per interval rather than on every limit write.
|
|
265
|
+
// A limit write re-asserts it once this is older than BATTERY_RATE_REVERT_REASSERT_MS, or
|
|
266
|
+
// straight away after a readback showed a new foreign value (the entry is then dropped).
|
|
267
|
+
batteryRateRevertAssertedAt = new Map();
|
|
268
|
+
// Last RvrtTms readback that disagreed with the configured value, per unit. A device stuck on
|
|
269
|
+
// that value warns and triggers an immediate re-assert once; after that it waits for the
|
|
270
|
+
// interval, so a device that clamps or ignores the write is not rewritten on every limit.
|
|
271
|
+
batteryRateRevertMismatchWarned = new Map();
|
|
263
272
|
constructor(
|
|
264
273
|
// The host application. Only used to obtain the default Modbus backend via
|
|
265
274
|
// `energyApp.useModbus()`. May be omitted (`undefined`) when a `modbusFactory` is supplied.
|
|
@@ -604,6 +613,9 @@ class SunspecModbusClient {
|
|
|
604
613
|
*/
|
|
605
614
|
async _openUnitOnce(host, port, unitId, connectTimeoutMs = this.resilience.connectTimeoutMs, useFallbackHosts = true) {
|
|
606
615
|
let candidate = null;
|
|
616
|
+
// Set once this attempt has failed; a connect that settles after that is nobody's socket.
|
|
617
|
+
let abandoned = false;
|
|
618
|
+
let connected = null;
|
|
607
619
|
const hosts = useFallbackHosts ? this.buildConnectHosts(host) : host;
|
|
608
620
|
const hostCount = Array.isArray(hosts) ? hosts.length : 1;
|
|
609
621
|
// Each host in the list gets its own `timeout`; bound the whole walk at count × budget so we
|
|
@@ -613,20 +625,40 @@ class SunspecModbusClient {
|
|
|
613
625
|
// Enforce the connect budget ourselves in addition to forwarding it as the transport's
|
|
614
626
|
// `timeout`: the transport applies it to the TCP handshake, but a sleeping/half-open peer
|
|
615
627
|
// can still leave the returned promise pending — bound it independently.
|
|
616
|
-
|
|
617
|
-
|
|
618
|
-
|
|
619
|
-
|
|
620
|
-
|
|
621
|
-
|
|
622
|
-
|
|
623
|
-
|
|
624
|
-
|
|
625
|
-
|
|
626
|
-
|
|
627
|
-
|
|
628
|
-
|
|
629
|
-
|
|
628
|
+
//
|
|
629
|
+
// Losing that race must not leak the socket: the transport does not bound a TLS
|
|
630
|
+
// handshake, so it can still complete after we gave up. Nobody would own that
|
|
631
|
+
// instance, and with a dedicated (non-pooled) connection it stays a live session on
|
|
632
|
+
// the device — a KOSTAL KSEM caps its Modbus/TLS clients and locks us out once enough
|
|
633
|
+
// timed-out attempts have piled up. Close whatever settles after the attempt failed.
|
|
634
|
+
candidate = await this.withTimeout('connect', unitId, overallBudgetMs, () => {
|
|
635
|
+
const connecting = this.useModbus().connect({
|
|
636
|
+
host: hosts,
|
|
637
|
+
port,
|
|
638
|
+
unitId,
|
|
639
|
+
timeout: connectTimeoutMs,
|
|
640
|
+
useTls: this.connectionParams?.useTls,
|
|
641
|
+
cert: this.connectionParams?.cert,
|
|
642
|
+
key: this.connectionParams?.key,
|
|
643
|
+
ca: this.connectionParams?.ca,
|
|
644
|
+
rejectUnauthorized: this.connectionParams?.rejectUnauthorized,
|
|
645
|
+
noParallelRequests: this.transport.noParallelRequests,
|
|
646
|
+
waitBetweenMessagesMs: this.transport.waitBetweenMessagesMs,
|
|
647
|
+
pooledConnection: this.transport.pooledConnection
|
|
648
|
+
});
|
|
649
|
+
connecting.then(instance => {
|
|
650
|
+
if (!instance)
|
|
651
|
+
return;
|
|
652
|
+
if (!abandoned) {
|
|
653
|
+
connected = instance;
|
|
654
|
+
return;
|
|
655
|
+
}
|
|
656
|
+
console.warn(`SunspecModbusClient: connect to ${host}:${port} unit ${unitId} completed after its ` +
|
|
657
|
+
`${overallBudgetMs}ms budget — closing the orphaned socket`);
|
|
658
|
+
void this.disconnectInstanceBounded(instance, unitId);
|
|
659
|
+
}, () => { });
|
|
660
|
+
return connecting;
|
|
661
|
+
});
|
|
630
662
|
if (!candidate) {
|
|
631
663
|
throw new Error(`useModbus().connect returned null for ${host}:${port} unit ${unitId}`);
|
|
632
664
|
}
|
|
@@ -653,8 +685,12 @@ class SunspecModbusClient {
|
|
|
653
685
|
this.recordOpen();
|
|
654
686
|
}
|
|
655
687
|
catch (err) {
|
|
656
|
-
|
|
657
|
-
|
|
688
|
+
abandoned = true;
|
|
689
|
+
// `connected` covers a connect that settled after the budget fired but before we got
|
|
690
|
+
// here; one that settles even later is closed by the handler on the connect promise.
|
|
691
|
+
const orphan = candidate ?? connected;
|
|
692
|
+
if (orphan) {
|
|
693
|
+
await this.disconnectInstanceBounded(orphan, unitId);
|
|
658
694
|
}
|
|
659
695
|
this.modbusInstances.delete(unitId);
|
|
660
696
|
this.faultTolerantReaders.delete(unitId);
|
|
@@ -2467,6 +2503,7 @@ class SunspecModbusClient {
|
|
|
2467
2503
|
// the object across many lines; stringify keeps the whole snapshot
|
|
2468
2504
|
// on one log entry so it stays grep-able and round-trippable.
|
|
2469
2505
|
console.debug(`[Battery] unit=${unitId} model=124 data=${JSON.stringify(data)}`);
|
|
2506
|
+
this.checkBatteryRateRevertReadback(unitId, data.inOutWRteRvrtTms);
|
|
2470
2507
|
return data;
|
|
2471
2508
|
}
|
|
2472
2509
|
else if (model.id === 802) {
|
|
@@ -2523,8 +2560,9 @@ class SunspecModbusClient {
|
|
|
2523
2560
|
}
|
|
2524
2561
|
}
|
|
2525
2562
|
/**
|
|
2526
|
-
* Set the Model 124 `InOutWRte_RvrtTms` (seconds) written
|
|
2527
|
-
*
|
|
2563
|
+
* Set the Model 124 `InOutWRte_RvrtTms` (seconds) written when the battery connects,
|
|
2564
|
+
* after every reconnect, and again by a limit write at most every
|
|
2565
|
+
* {@link BATTERY_RATE_REVERT_REASSERT_MS} — e.g. 30 or 60. When no fresh rate write arrives within this window
|
|
2528
2566
|
* the device drops the limit and manages itself again, so a hub that goes
|
|
2529
2567
|
* offline cannot leave the battery blocked. The schedule handler refreshes an
|
|
2530
2568
|
* active limit every third of this value.
|
|
@@ -2543,6 +2581,8 @@ class SunspecModbusClient {
|
|
|
2543
2581
|
`${sunspec_interfaces_js_1.MIN_BATTERY_RATE_REVERT_TIMEOUT_SECONDS} and ${sunspec_interfaces_js_1.MAX_BATTERY_RATE_REVERT_TIMEOUT_SECONDS}`);
|
|
2544
2582
|
}
|
|
2545
2583
|
this.batteryRateRevertTimeoutSeconds = seconds;
|
|
2584
|
+
// A new value is due on the next limit write, not a minute later.
|
|
2585
|
+
this.batteryRateRevertAssertedAt.clear();
|
|
2546
2586
|
}
|
|
2547
2587
|
/** Current Model 124 `InOutWRte_RvrtTms` in seconds. */
|
|
2548
2588
|
getBatteryRateRevertTimeoutSeconds() {
|
|
@@ -2609,6 +2649,13 @@ class SunspecModbusClient {
|
|
|
2609
2649
|
// Storage control mode (Register 5) — written LAST so all
|
|
2610
2650
|
// governing parameters are already in place when the device
|
|
2611
2651
|
// transitions into the new mode.
|
|
2652
|
+
// A limit only holds as long as InOutWRte_RvrtTms allows. Re-assert our value before
|
|
2653
|
+
// the mode write so the new limit gets the full window — a device left on a foreign
|
|
2654
|
+
// value (1 s on a GEN24 in the field) drops every limit a second after each write.
|
|
2655
|
+
if (controls.storCtlMod !== undefined && controls.storCtlMod !== 0
|
|
2656
|
+
&& this.isBatteryRateRevertDue(unitId)) {
|
|
2657
|
+
await this.writeBatteryRateRevertTimeout(unitId);
|
|
2658
|
+
}
|
|
2612
2659
|
if (controls.storCtlMod !== undefined) {
|
|
2613
2660
|
// storCtlMod = 0 is rejected with Modbus Exception code 3 (Illegal Data Value)
|
|
2614
2661
|
// by some devices (e.g. Fronius GEN24). 0 means "no external control" per the
|
|
@@ -2632,8 +2679,10 @@ class SunspecModbusClient {
|
|
|
2632
2679
|
}
|
|
2633
2680
|
/**
|
|
2634
2681
|
* Write the configured InOutWRte_RvrtTms (Model 124 offset 15) to the device.
|
|
2635
|
-
* Called
|
|
2636
|
-
*
|
|
2682
|
+
* Called by `SunspecBattery.connect()`, once per recovered connection, and by
|
|
2683
|
+
* {@link writeBatteryControls} before a limit when the last write is older than
|
|
2684
|
+
* {@link BATTERY_RATE_REVERT_REASSERT_MS} or a readback disagreed. The device should keep
|
|
2685
|
+
* the value, but one GEN24 in the field sat on 1 s anyway.
|
|
2637
2686
|
*
|
|
2638
2687
|
* Never throws: a device that rejects the register still takes limits, it just
|
|
2639
2688
|
* won't revert them on its own (the pre-existing behaviour). The first failure
|
|
@@ -2650,6 +2699,9 @@ class SunspecModbusClient {
|
|
|
2650
2699
|
return false;
|
|
2651
2700
|
}
|
|
2652
2701
|
const seconds = this.batteryRateRevertTimeoutSeconds;
|
|
2702
|
+
// Stamp the attempt, not the success: a device that rejects the register must not be
|
|
2703
|
+
// retried (and logged as a failed write) on every limit write.
|
|
2704
|
+
this.batteryRateRevertAssertedAt.set(unitId, Date.now());
|
|
2653
2705
|
try {
|
|
2654
2706
|
await this.writeRegisterValue(unitId, model.address + 15, seconds, 'uint16');
|
|
2655
2707
|
console.log(`Unit ${unitId}: set battery rate revert timeout (InOutWRte_RvrtTms) to ${seconds}s`);
|
|
@@ -2664,6 +2716,36 @@ class SunspecModbusClient {
|
|
|
2664
2716
|
return false;
|
|
2665
2717
|
}
|
|
2666
2718
|
}
|
|
2719
|
+
/** Whether a limit write should re-assert InOutWRte_RvrtTms first. */
|
|
2720
|
+
isBatteryRateRevertDue(unitId) {
|
|
2721
|
+
const assertedAt = this.batteryRateRevertAssertedAt.get(unitId);
|
|
2722
|
+
return assertedAt === undefined || Date.now() - assertedAt >= sunspec_interfaces_js_1.BATTERY_RATE_REVERT_REASSERT_MS;
|
|
2723
|
+
}
|
|
2724
|
+
/**
|
|
2725
|
+
* Compare a Model 124 readback of InOutWRte_RvrtTms with the configured value. A mismatch
|
|
2726
|
+
* means our write never landed or something reset it. A new foreign value is logged once and
|
|
2727
|
+
* makes the next limit write re-assert immediately; if the same value is still there after
|
|
2728
|
+
* that, the device clamps or ignores the write and re-asserts fall back to the interval.
|
|
2729
|
+
*/
|
|
2730
|
+
checkBatteryRateRevertReadback(unitId, readback) {
|
|
2731
|
+
if (readback === undefined)
|
|
2732
|
+
return;
|
|
2733
|
+
// Nothing written since connect or since setBatteryRateRevertTimeoutSeconds(): the device
|
|
2734
|
+
// still holding the old value is expected, and the next limit write asserts anyway.
|
|
2735
|
+
if (!this.batteryRateRevertAssertedAt.has(unitId))
|
|
2736
|
+
return;
|
|
2737
|
+
const expected = this.batteryRateRevertTimeoutSeconds;
|
|
2738
|
+
if (readback === expected) {
|
|
2739
|
+
this.batteryRateRevertMismatchWarned.delete(unitId);
|
|
2740
|
+
return;
|
|
2741
|
+
}
|
|
2742
|
+
if (this.batteryRateRevertMismatchWarned.get(unitId) !== readback) {
|
|
2743
|
+
this.batteryRateRevertMismatchWarned.set(unitId, readback);
|
|
2744
|
+
this.batteryRateRevertAssertedAt.delete(unitId);
|
|
2745
|
+
console.warn(`Unit ${unitId}: InOutWRte_RvrtTms reads ${readback}s, expected ${expected}s — ` +
|
|
2746
|
+
`re-asserting with the next battery limit write`);
|
|
2747
|
+
}
|
|
2748
|
+
}
|
|
2667
2749
|
/**
|
|
2668
2750
|
* Set battery storage mode (simplified interface)
|
|
2669
2751
|
*/
|
|
@@ -141,6 +141,8 @@ export declare class SunspecModbusClient {
|
|
|
141
141
|
private unitSessionReportedLost;
|
|
142
142
|
private batteryRateRevertTimeoutSeconds;
|
|
143
143
|
private batteryRateRevertWarnedUnits;
|
|
144
|
+
private batteryRateRevertAssertedAt;
|
|
145
|
+
private batteryRateRevertMismatchWarned;
|
|
144
146
|
constructor(energyApp: EnergyApp | undefined, transport?: IModbusTransportConfig, resilience?: IModbusResilienceConfig, modbusFactory?: EnergyAppModbus | undefined);
|
|
145
147
|
/**
|
|
146
148
|
* The Modbus backend used to open per-unit connections: the caller-supplied {@link modbusFactory}
|
|
@@ -677,8 +679,9 @@ export declare class SunspecModbusClient {
|
|
|
677
679
|
*/
|
|
678
680
|
readBatteryData(unitId: number): Promise<SunspecBatteryData | null>;
|
|
679
681
|
/**
|
|
680
|
-
* Set the Model 124 `InOutWRte_RvrtTms` (seconds) written
|
|
681
|
-
*
|
|
682
|
+
* Set the Model 124 `InOutWRte_RvrtTms` (seconds) written when the battery connects,
|
|
683
|
+
* after every reconnect, and again by a limit write at most every
|
|
684
|
+
* {@link BATTERY_RATE_REVERT_REASSERT_MS} — e.g. 30 or 60. When no fresh rate write arrives within this window
|
|
682
685
|
* the device drops the limit and manages itself again, so a hub that goes
|
|
683
686
|
* offline cannot leave the battery blocked. The schedule handler refreshes an
|
|
684
687
|
* active limit every third of this value.
|
|
@@ -698,8 +701,10 @@ export declare class SunspecModbusClient {
|
|
|
698
701
|
writeBatteryControls(unitId: number, controls: Partial<SunspecBatteryControls>): Promise<boolean>;
|
|
699
702
|
/**
|
|
700
703
|
* Write the configured InOutWRte_RvrtTms (Model 124 offset 15) to the device.
|
|
701
|
-
* Called
|
|
702
|
-
*
|
|
704
|
+
* Called by `SunspecBattery.connect()`, once per recovered connection, and by
|
|
705
|
+
* {@link writeBatteryControls} before a limit when the last write is older than
|
|
706
|
+
* {@link BATTERY_RATE_REVERT_REASSERT_MS} or a readback disagreed. The device should keep
|
|
707
|
+
* the value, but one GEN24 in the field sat on 1 s anyway.
|
|
703
708
|
*
|
|
704
709
|
* Never throws: a device that rejects the register still takes limits, it just
|
|
705
710
|
* won't revert them on its own (the pre-existing behaviour). The first failure
|
|
@@ -709,6 +714,15 @@ export declare class SunspecModbusClient {
|
|
|
709
714
|
* or the write failed.
|
|
710
715
|
*/
|
|
711
716
|
writeBatteryRateRevertTimeout(unitId: number): Promise<boolean>;
|
|
717
|
+
/** Whether a limit write should re-assert InOutWRte_RvrtTms first. */
|
|
718
|
+
private isBatteryRateRevertDue;
|
|
719
|
+
/**
|
|
720
|
+
* Compare a Model 124 readback of InOutWRte_RvrtTms with the configured value. A mismatch
|
|
721
|
+
* means our write never landed or something reset it. A new foreign value is logged once and
|
|
722
|
+
* makes the next limit write re-assert immediately; if the same value is still there after
|
|
723
|
+
* that, the device clamps or ignores the write and re-asserts fall back to the interval.
|
|
724
|
+
*/
|
|
725
|
+
private checkBatteryRateRevertReadback;
|
|
712
726
|
/**
|
|
713
727
|
* Set battery storage mode (simplified interface)
|
|
714
728
|
*/
|
package/dist/cjs/version.cjs
CHANGED
package/dist/cjs/version.d.cts
CHANGED
|
@@ -1,12 +1,14 @@
|
|
|
1
1
|
import { BatteryCalibrator, type BatteryCalibratorOptions, type CalibrationResult } from "@enyo-energy/appliance-calibration";
|
|
2
2
|
import { EnyoBatteryFeature } from "@enyo-energy/energy-app-sdk/dist/types/enyo-battery-appliance.js";
|
|
3
3
|
import { BatteryControlsClient } from "./sunspec-battery-schedule-handler.js";
|
|
4
|
-
import { type SunspecBatteryControls, type SunspecBatteryData } from "./sunspec-interfaces.js";
|
|
4
|
+
import { type SunspecBatteryControls, type SunspecBatteryData, SunspecGridChargeMethod } from "./sunspec-interfaces.js";
|
|
5
5
|
export interface SunspecBatteryFeatureCalibratorOptions extends BatteryCalibratorOptions<SunspecBatteryControls> {
|
|
6
6
|
sunspecClient: BatteryControlsClient;
|
|
7
7
|
unitId: number;
|
|
8
8
|
/** Pulls the latest battery data so the orchestrator can pre-check SoC. */
|
|
9
9
|
readBatteryData: () => Promise<SunspecBatteryData | null>;
|
|
10
|
+
/** Register form the grid-charge probe tests; must match the schedule handler's. Defaults to ChargeRateLimit. */
|
|
11
|
+
gridChargeMethod?: SunspecGridChargeMethod;
|
|
10
12
|
}
|
|
11
13
|
/**
|
|
12
14
|
* SunSpec-specific calibrator that exercises each of the four controllable
|
|
@@ -48,6 +50,7 @@ export declare class SunspecBatteryFeatureCalibrator extends BatteryCalibrator<S
|
|
|
48
50
|
private readonly sunspecClient;
|
|
49
51
|
private readonly unitId;
|
|
50
52
|
private readonly readBatteryData;
|
|
53
|
+
private readonly gridChargeMethod;
|
|
51
54
|
private readonly probeConfig;
|
|
52
55
|
private readonly probeClock;
|
|
53
56
|
private readonly probeSnapshotService;
|
|
@@ -1,6 +1,7 @@
|
|
|
1
1
|
import { BatteryCalibrator, DEFAULT_BATTERY_CALIBRATOR_CONFIG, } from "@enyo-energy/appliance-calibration";
|
|
2
2
|
import { EnyoBatteryFeature } from "@enyo-energy/energy-app-sdk/dist/types/enyo-battery-appliance.js";
|
|
3
|
-
import {
|
|
3
|
+
import { gridChargeControls } from "./sunspec-battery-grid-charge.js";
|
|
4
|
+
import { SUNSPEC_CONTROLLABLE_FEATURES, SunspecChargeSource, SunspecGridChargeMethod, SunspecStorageControlMode, } from "./sunspec-interfaces.js";
|
|
4
5
|
/**
|
|
5
6
|
* SoC band each probe needs to operate in. Outside the band the probe returns
|
|
6
7
|
* `not-supported` instead of running — there's no useful signal when the
|
|
@@ -53,6 +54,7 @@ export class SunspecBatteryFeatureCalibrator extends BatteryCalibrator {
|
|
|
53
54
|
sunspecClient;
|
|
54
55
|
unitId;
|
|
55
56
|
readBatteryData;
|
|
57
|
+
gridChargeMethod;
|
|
56
58
|
probeConfig;
|
|
57
59
|
probeClock;
|
|
58
60
|
// Local refs to the same instances the parent stores privately. We keep
|
|
@@ -67,6 +69,7 @@ export class SunspecBatteryFeatureCalibrator extends BatteryCalibrator {
|
|
|
67
69
|
this.sunspecClient = options.sunspecClient;
|
|
68
70
|
this.unitId = options.unitId;
|
|
69
71
|
this.readBatteryData = options.readBatteryData;
|
|
72
|
+
this.gridChargeMethod = options.gridChargeMethod ?? SunspecGridChargeMethod.ChargeRateLimit;
|
|
70
73
|
this.probeConfig = { ...DEFAULT_BATTERY_CALIBRATOR_CONFIG, ...options.config };
|
|
71
74
|
this.probeSnapshotService = options.snapshotService;
|
|
72
75
|
this.probeResultStore = options.resultStore;
|
|
@@ -157,11 +160,10 @@ export class SunspecBatteryFeatureCalibrator extends BatteryCalibrator {
|
|
|
157
160
|
}
|
|
158
161
|
const baselineBatW = this.sunspecDriver.readBatteryPowerW() ?? 0;
|
|
159
162
|
const baselineGridW = this.sunspecDriver.readGridPowerW() ?? 0;
|
|
163
|
+
// wChaMax is lowered to the test power, so a 100 % rate charges at exactly testPowerW.
|
|
160
164
|
const wrote = await this.sunspecClient.writeBatteryControls(this.unitId, {
|
|
161
|
-
chaGriSet: SunspecChargeSource.GRID,
|
|
162
165
|
wChaMax: this.probeConfig.testPowerW,
|
|
163
|
-
|
|
164
|
-
storCtlMod: SunspecStorageControlMode.CHARGE,
|
|
166
|
+
...gridChargeControls(this.gridChargeMethod, 100),
|
|
165
167
|
});
|
|
166
168
|
if (!wrote) {
|
|
167
169
|
return { verdict: 'failed', note: 'writeBatteryControls returned false for grid charge' };
|
|
@@ -0,0 +1,9 @@
|
|
|
1
|
+
import { type SunspecBatteryControls, SunspecGridChargeMethod } from "./sunspec-interfaces.js";
|
|
2
|
+
/**
|
|
3
|
+
* The Model 124 register set that charges the battery from the grid at `ratePct` of `WChaMax`,
|
|
4
|
+
* in the form the device acts on — see {@link SunspecGridChargeMethod}. Shared by the schedule
|
|
5
|
+
* handler and the calibrator's grid-charge probe, so the probe tests the write production uses.
|
|
6
|
+
*/
|
|
7
|
+
export declare function gridChargeControls(method: SunspecGridChargeMethod, ratePct: number): Partial<SunspecBatteryControls>;
|
|
8
|
+
/** The fields {@link gridChargeControls} writes, for the snapshot service's modification record. */
|
|
9
|
+
export declare function gridChargeFields(controls: Partial<SunspecBatteryControls>): (keyof SunspecBatteryControls)[];
|
|
@@ -0,0 +1,28 @@
|
|
|
1
|
+
import { SunspecChargeSource, SunspecGridChargeMethod, SunspecStorageControlMode, } from "./sunspec-interfaces.js";
|
|
2
|
+
/**
|
|
3
|
+
* The Model 124 register set that charges the battery from the grid at `ratePct` of `WChaMax`,
|
|
4
|
+
* in the form the device acts on — see {@link SunspecGridChargeMethod}. Shared by the schedule
|
|
5
|
+
* handler and the calibrator's grid-charge probe, so the probe tests the write production uses.
|
|
6
|
+
*/
|
|
7
|
+
export function gridChargeControls(method, ratePct) {
|
|
8
|
+
switch (method) {
|
|
9
|
+
case SunspecGridChargeMethod.ChargeRateLimit:
|
|
10
|
+
return {
|
|
11
|
+
chaGriSet: SunspecChargeSource.GRID,
|
|
12
|
+
inWRte: ratePct,
|
|
13
|
+
storCtlMod: SunspecStorageControlMode.CHARGE,
|
|
14
|
+
};
|
|
15
|
+
case SunspecGridChargeMethod.NegativeDischargeRate:
|
|
16
|
+
return {
|
|
17
|
+
chaGriSet: SunspecChargeSource.GRID,
|
|
18
|
+
inWRte: 100,
|
|
19
|
+
outWRte: -ratePct,
|
|
20
|
+
storCtlMod: SunspecStorageControlMode.DISCHARGE,
|
|
21
|
+
};
|
|
22
|
+
}
|
|
23
|
+
}
|
|
24
|
+
/** The fields {@link gridChargeControls} writes, for the snapshot service's modification record. */
|
|
25
|
+
export function gridChargeFields(controls) {
|
|
26
|
+
const fields = ['chaGriSet', 'inWRte', 'outWRte', 'storCtlMod'];
|
|
27
|
+
return fields.filter(field => controls[field] !== undefined);
|
|
28
|
+
}
|
|
@@ -1,7 +1,7 @@
|
|
|
1
1
|
import { StorageScheduleHandler, type ActiveStorageScheduleEntry, type StorageScheduleHandlerOptions } from "@enyo-energy/energy-app-sdk/dist/implementations/storage/storage-schedule-handler.js";
|
|
2
2
|
import { type EnyoDataBusSetStorageScheduleV1 } from "@enyo-energy/energy-app-sdk/dist/types/enyo-data-bus-value.js";
|
|
3
3
|
import { type SnapshotService } from "@enyo-energy/appliance-calibration";
|
|
4
|
-
import { type SunspecBatteryControls } from "./sunspec-interfaces.js";
|
|
4
|
+
import { type SunspecBatteryControls, SunspecGridChargeMethod } from "./sunspec-interfaces.js";
|
|
5
5
|
/**
|
|
6
6
|
* Narrow interface covering only the modbus reads/writes the schedule handler
|
|
7
7
|
* needs. The full `SunspecModbusClient` structurally satisfies this; pinning
|
|
@@ -47,6 +47,8 @@ export interface SunspecBatteryScheduleHandlerOptions extends StorageScheduleHan
|
|
|
47
47
|
/** Lazy so the snapshot service can be initialised after the handler. */
|
|
48
48
|
getSnapshotService: () => BatteryModificationRecorder | undefined;
|
|
49
49
|
onErrorCallback?: (err: Error) => void;
|
|
50
|
+
/** Register form of a Charge entry. Defaults to {@link SunspecGridChargeMethod.ChargeRateLimit}. */
|
|
51
|
+
gridChargeMethod?: SunspecGridChargeMethod;
|
|
50
52
|
}
|
|
51
53
|
/**
|
|
52
54
|
* Concrete `StorageScheduleHandler` for SunSpec Model 124 batteries. The base
|
|
@@ -61,6 +63,7 @@ export declare class SunspecBatteryScheduleHandler extends StorageScheduleHandle
|
|
|
61
63
|
private readonly applianceIdForLog;
|
|
62
64
|
private readonly getSnapshotService;
|
|
63
65
|
private readonly onErrorCallback?;
|
|
66
|
+
private readonly gridChargeMethod;
|
|
64
67
|
private installedWChaMax;
|
|
65
68
|
/**
|
|
66
69
|
* Sticky pre-schedule snapshot, captured once on the first `onInit` and
|
|
@@ -1,6 +1,7 @@
|
|
|
1
1
|
import { StorageScheduleHandler, } from "@enyo-energy/energy-app-sdk/dist/implementations/storage/storage-schedule-handler.js";
|
|
2
2
|
import { EnyoStorageScheduleDirectionEnum, EnyoStorageScheduleModeEnum, } from "@enyo-energy/energy-app-sdk/dist/types/enyo-data-bus-value.js";
|
|
3
|
-
import { SunspecChargeSource, SunspecStorageControlMode, } from "./sunspec-interfaces.js";
|
|
3
|
+
import { SunspecChargeSource, SunspecGridChargeMethod, SunspecStorageControlMode, } from "./sunspec-interfaces.js";
|
|
4
|
+
import { gridChargeControls, gridChargeFields } from "./sunspec-battery-grid-charge.js";
|
|
4
5
|
/**
|
|
5
6
|
* How often the keepalive checks whether the active limit is due a refresh.
|
|
6
7
|
* The refresh itself happens every third of the revert timeout; this only
|
|
@@ -20,6 +21,7 @@ export class SunspecBatteryScheduleHandler extends StorageScheduleHandler {
|
|
|
20
21
|
applianceIdForLog;
|
|
21
22
|
getSnapshotService;
|
|
22
23
|
onErrorCallback;
|
|
24
|
+
gridChargeMethod;
|
|
23
25
|
installedWChaMax;
|
|
24
26
|
/**
|
|
25
27
|
* Sticky pre-schedule snapshot, captured once on the first `onInit` and
|
|
@@ -70,6 +72,7 @@ export class SunspecBatteryScheduleHandler extends StorageScheduleHandler {
|
|
|
70
72
|
this.applianceIdForLog = opts.applianceId;
|
|
71
73
|
this.getSnapshotService = opts.getSnapshotService;
|
|
72
74
|
this.onErrorCallback = opts.onErrorCallback;
|
|
75
|
+
this.gridChargeMethod = opts.gridChargeMethod ?? SunspecGridChargeMethod.ChargeRateLimit;
|
|
73
76
|
this.interval = opts.interval;
|
|
74
77
|
this.clock = opts.now ?? (() => Date.now());
|
|
75
78
|
}
|
|
@@ -292,12 +295,9 @@ export class SunspecBatteryScheduleHandler extends StorageScheduleHandler {
|
|
|
292
295
|
}
|
|
293
296
|
const pct = Math.min(100, Math.max(0, (powerW / baseline) * 100));
|
|
294
297
|
if (direction === EnyoStorageScheduleDirectionEnum.Charge) {
|
|
295
|
-
|
|
296
|
-
|
|
297
|
-
|
|
298
|
-
storCtlMod: SunspecStorageControlMode.CHARGE,
|
|
299
|
-
});
|
|
300
|
-
await this.getSnapshotService()?.recordModification(['chaGriSet', 'inWRte', 'storCtlMod']);
|
|
298
|
+
const controls = gridChargeControls(this.gridChargeMethod, pct);
|
|
299
|
+
await this.sunspecClient.writeBatteryControls(this.unitId, controls);
|
|
300
|
+
await this.getSnapshotService()?.recordModification(gridChargeFields(controls));
|
|
301
301
|
}
|
|
302
302
|
else {
|
|
303
303
|
await this.sunspecClient.writeBatteryControls(this.unitId, {
|
|
@@ -1,4 +1,4 @@
|
|
|
1
|
-
import { type IRetryConfig, type SunspecBatteryBaseData, SunspecBatteryCapability, type SunspecBatteryControls, type SunspecBatteryData, type SunspecBatteryFeatureMode, type SunspecInverterData, SunspecInverterCapability, SunspecPvPowerSource, type SunspecInverterMetadataConfig, type
|
|
1
|
+
import { type IRetryConfig, type SunspecBatteryBaseData, SunspecBatteryCapability, type SunspecBatteryControls, type SunspecBatteryData, type SunspecBatteryFeatureMode, type SunspecInverterData, SunspecInverterCapability, SunspecPvPowerSource, type SunspecInverterMetadataConfig, type SunspecBatteryConfig, SunspecPvPowerOrigin, type SunspecInverterReading, type SunspecBatteryReading, SunspecMeterCapability, type SunspecMPPTData, SunspecStorageMode, type SunspecCustomDeviceConfig } from "./sunspec-interfaces.js";
|
|
2
2
|
import { ApplianceManager, EnergyApp } from "@enyo-energy/energy-app-sdk";
|
|
3
3
|
import { type EnyoAppliance, type EnyoApplianceErrorCode, EnyoApplianceName } from "@enyo-energy/energy-app-sdk/dist/types/enyo-appliance.js";
|
|
4
4
|
import { EnyoNetworkDevice } from "@enyo-energy/energy-app-sdk/dist/types/enyo-network-device.js";
|
|
@@ -557,6 +557,8 @@ export declare class SunspecBattery extends BaseSunspecDevice {
|
|
|
557
557
|
private batteryCalibrator?;
|
|
558
558
|
private calibrationResultStore?;
|
|
559
559
|
private scheduleHandler;
|
|
560
|
+
/** Register form of a grid charge, for both the schedule handler and the calibration probe. */
|
|
561
|
+
private readonly gridChargeMethod;
|
|
560
562
|
/**
|
|
561
563
|
* Battery features that imply outbound control writes from the host action-taker.
|
|
562
564
|
* These are stripped from `appliance.battery.features` until the calibration result
|
|
@@ -564,7 +566,7 @@ export declare class SunspecBattery extends BaseSunspecDevice {
|
|
|
564
566
|
* {@link computeAdvertisedFeatures}.
|
|
565
567
|
*/
|
|
566
568
|
private static readonly CONTROLLABLE_FEATURES;
|
|
567
|
-
constructor(energyApp: EnergyApp, name: EnyoApplianceName[], networkDevice: EnyoNetworkDevice, sunspecClient: SunspecModbusClient, applianceManager: ApplianceManager, featureMode: SunspecBatteryFeatureMode, unitId?: number, port?: number, baseAddress?: number, capabilities?: SunspecBatteryCapability[], retryConfig?: IRetryConfig, appliance?: EnyoAppliance, useTls?: boolean,
|
|
569
|
+
constructor(energyApp: EnergyApp, name: EnyoApplianceName[], networkDevice: EnyoNetworkDevice, sunspecClient: SunspecModbusClient, applianceManager: ApplianceManager, featureMode: SunspecBatteryFeatureMode, unitId?: number, port?: number, baseAddress?: number, capabilities?: SunspecBatteryCapability[], retryConfig?: IRetryConfig, appliance?: EnyoAppliance, useTls?: boolean, config?: SunspecBatteryConfig);
|
|
568
570
|
/**
|
|
569
571
|
* Last known round-trip efficiency, seeded from the constructor config and replaceable at
|
|
570
572
|
* runtime via {@link setRoundTripEfficiencyPercent}. Undefined = not yet known; the SDK then
|
|
@@ -587,6 +589,17 @@ export declare class SunspecBattery extends BaseSunspecDevice {
|
|
|
587
589
|
* Spreading an explicit `undefined` would erase a value the host set elsewhere.
|
|
588
590
|
*/
|
|
589
591
|
private configuredBatteryMetadata;
|
|
592
|
+
/**
|
|
593
|
+
* Whether the host may charge this battery from the grid. Follows the advertised
|
|
594
|
+
* `GridCharging` feature, NOT the live `chaGriSet` register: our own schedule handler
|
|
595
|
+
* writes GRID on every Charge and PV on Discharge/Auto, so the register only says
|
|
596
|
+
* whether we are grid-charging right now. Publishing it made the flag `false` whenever
|
|
597
|
+
* the pack sat on Auto (all night), and enyo-control honours an explicit `false` by
|
|
598
|
+
* planning no buys at all (ENY-1241). The value is always set, never omitted, because
|
|
599
|
+
* `updateAppliance` merges `battery` and would otherwise keep a stale `false`.
|
|
600
|
+
* The live register stays available through {@link isGridChargingEnabled}.
|
|
601
|
+
*/
|
|
602
|
+
private gridChargingEnabled;
|
|
590
603
|
/**
|
|
591
604
|
* Wire the battery into `@enyo-energy/appliance-calibration`'s
|
|
592
605
|
* `BatteryCalibrator` test-charge flow. Call once after {@link connect}.
|
package/dist/sunspec-devices.js
CHANGED
|
@@ -1,4 +1,4 @@
|
|
|
1
|
-
import { SunspecBatteryChargeState, SunspecBatteryFeatureModeKind, SunspecEnableControl, SunspecInverterCapability, SunspecPvPowerSource, SunspecPvPowerOrigin, SunspecInverterEvent1, SunspecInverterOperatingState, SunspecModelId, SunspecMPPTOperatingState, SunspecStorageMode, SUNSPEC_CONNECTION_LOST_CODE } from "./sunspec-interfaces.js";
|
|
1
|
+
import { SunspecBatteryChargeState, SunspecBatteryFeatureModeKind, SunspecEnableControl, SunspecInverterCapability, SunspecPvPowerSource, SunspecGridChargeMethod, SunspecPvPowerOrigin, SunspecInverterEvent1, SunspecInverterOperatingState, SunspecModelId, SunspecMPPTOperatingState, SunspecStorageMode, SUNSPEC_CONNECTION_LOST_CODE } from "./sunspec-interfaces.js";
|
|
2
2
|
import { randomUUID } from "node:crypto";
|
|
3
3
|
import { EnyoApplianceConnectionType, EnyoApplianceStateEnum, EnyoApplianceStatusEnum, EnyoApplianceTopologyFeatureEnum, EnyoApplianceTypeEnum } from "@enyo-energy/energy-app-sdk/dist/types/enyo-appliance.js";
|
|
4
4
|
import { ConnectionRetryManager } from "./connection-retry-manager.js";
|
|
@@ -1507,6 +1507,14 @@ export function deriveStorageMode(controls) {
|
|
|
1507
1507
|
if (chargeLimited && dischargeLimited && controls.inWRte === 0 && controls.outWRte === 0) {
|
|
1508
1508
|
return SunspecStorageMode.HOLDING;
|
|
1509
1509
|
}
|
|
1510
|
+
// A limit below zero reverses its direction: a negative discharge rate is a forced charge
|
|
1511
|
+
// (SunspecGridChargeMethod.NegativeDischargeRate), a negative charge rate a forced discharge.
|
|
1512
|
+
if (dischargeLimited && controls.outWRte !== undefined && controls.outWRte < 0) {
|
|
1513
|
+
return SunspecStorageMode.CHARGE;
|
|
1514
|
+
}
|
|
1515
|
+
if (chargeLimited && controls.inWRte !== undefined && controls.inWRte < 0) {
|
|
1516
|
+
return SunspecStorageMode.DISCHARGE;
|
|
1517
|
+
}
|
|
1510
1518
|
return dischargeLimited && !chargeLimited
|
|
1511
1519
|
? SunspecStorageMode.DISCHARGE
|
|
1512
1520
|
: SunspecStorageMode.CHARGE;
|
|
@@ -1529,6 +1537,8 @@ export class SunspecBattery extends BaseSunspecDevice {
|
|
|
1529
1537
|
batteryCalibrator;
|
|
1530
1538
|
calibrationResultStore;
|
|
1531
1539
|
scheduleHandler;
|
|
1540
|
+
/** Register form of a grid charge, for both the schedule handler and the calibration probe. */
|
|
1541
|
+
gridChargeMethod;
|
|
1532
1542
|
/**
|
|
1533
1543
|
* Battery features that imply outbound control writes from the host action-taker.
|
|
1534
1544
|
* These are stripped from `appliance.battery.features` until the calibration result
|
|
@@ -1542,13 +1552,14 @@ export class SunspecBattery extends BaseSunspecDevice {
|
|
|
1542
1552
|
EnyoBatteryFeature.DischargeLimitation,
|
|
1543
1553
|
];
|
|
1544
1554
|
constructor(energyApp, name, networkDevice, sunspecClient, applianceManager, featureMode, unitId = 1, port = 502, baseAddress = 40000, capabilities = [], retryConfig, appliance, useTls,
|
|
1545
|
-
// Battery facts no register carries (
|
|
1546
|
-
//
|
|
1547
|
-
|
|
1555
|
+
// Battery facts no register carries (forwarded onto `appliance.battery` on connect;
|
|
1556
|
+
// see SunspecBatteryMetadataConfig) plus how the device is driven.
|
|
1557
|
+
config = {}) {
|
|
1548
1558
|
super(energyApp, name, networkDevice, sunspecClient, applianceManager, unitId, port, baseAddress, retryConfig, appliance, useTls);
|
|
1549
1559
|
this.featureMode = featureMode;
|
|
1550
1560
|
this.capabilities = capabilities;
|
|
1551
|
-
this.roundTripEfficiencyPercent =
|
|
1561
|
+
this.roundTripEfficiencyPercent = config.roundTripEfficiencyPercent;
|
|
1562
|
+
this.gridChargeMethod = config.gridChargeMethod ?? SunspecGridChargeMethod.ChargeRateLimit;
|
|
1552
1563
|
}
|
|
1553
1564
|
/**
|
|
1554
1565
|
* Last known round-trip efficiency, seeded from the constructor config and replaceable at
|
|
@@ -1595,6 +1606,19 @@ export class SunspecBattery extends BaseSunspecDevice {
|
|
|
1595
1606
|
? {}
|
|
1596
1607
|
: { roundTripEfficiencyPercent: this.roundTripEfficiencyPercent };
|
|
1597
1608
|
}
|
|
1609
|
+
/**
|
|
1610
|
+
* Whether the host may charge this battery from the grid. Follows the advertised
|
|
1611
|
+
* `GridCharging` feature, NOT the live `chaGriSet` register: our own schedule handler
|
|
1612
|
+
* writes GRID on every Charge and PV on Discharge/Auto, so the register only says
|
|
1613
|
+
* whether we are grid-charging right now. Publishing it made the flag `false` whenever
|
|
1614
|
+
* the pack sat on Auto (all night), and enyo-control honours an explicit `false` by
|
|
1615
|
+
* planning no buys at all (ENY-1241). The value is always set, never omitted, because
|
|
1616
|
+
* `updateAppliance` merges `battery` and would otherwise keep a stale `false`.
|
|
1617
|
+
* The live register stays available through {@link isGridChargingEnabled}.
|
|
1618
|
+
*/
|
|
1619
|
+
gridChargingEnabled(features) {
|
|
1620
|
+
return features.includes(EnyoBatteryFeature.GridCharging);
|
|
1621
|
+
}
|
|
1598
1622
|
/**
|
|
1599
1623
|
* Wire the battery into `@enyo-energy/appliance-calibration`'s
|
|
1600
1624
|
* `BatteryCalibrator` test-charge flow. Call once after {@link connect}.
|
|
@@ -1629,6 +1653,7 @@ export class SunspecBattery extends BaseSunspecDevice {
|
|
|
1629
1653
|
sunspecClient: this.sunspecClient,
|
|
1630
1654
|
unitId: this.unitId,
|
|
1631
1655
|
readBatteryData: () => this.sunspecClient.readBatteryData(this.unitId),
|
|
1656
|
+
gridChargeMethod: this.gridChargeMethod,
|
|
1632
1657
|
snapshotService: this.snapshotService,
|
|
1633
1658
|
resultStore: opts.resultStore,
|
|
1634
1659
|
config: opts.config,
|
|
@@ -1690,8 +1715,8 @@ export class SunspecBattery extends BaseSunspecDevice {
|
|
|
1690
1715
|
throw new Error('No battery model found in device');
|
|
1691
1716
|
}
|
|
1692
1717
|
// Give every limit a revert timeout so a hub that goes offline cannot leave the
|
|
1693
|
-
// battery blocked (devices ship with 0 = never revert). Written
|
|
1694
|
-
// schedule handler refreshes active limits inside this window.
|
|
1718
|
+
// battery blocked (devices ship with 0 = never revert). Written here and re-asserted
|
|
1719
|
+
// by limit writes; the schedule handler refreshes active limits inside this window.
|
|
1695
1720
|
await this.sunspecClient.writeBatteryRateRevertTimeout(this.unitId);
|
|
1696
1721
|
// Get device info
|
|
1697
1722
|
const commonData = await this.sunspecClient.readCommonBlock(this.unitId);
|
|
@@ -1723,7 +1748,7 @@ export class SunspecBattery extends BaseSunspecDevice {
|
|
|
1723
1748
|
activeChargeLimitW: activeChargeLimitW,
|
|
1724
1749
|
activeDischargeLimitW: activeDischargeLimitW,
|
|
1725
1750
|
features,
|
|
1726
|
-
gridChargingEnabled:
|
|
1751
|
+
gridChargingEnabled: this.gridChargingEnabled(features),
|
|
1727
1752
|
...this.configuredBatteryMetadata()
|
|
1728
1753
|
}
|
|
1729
1754
|
});
|
|
@@ -1752,7 +1777,7 @@ export class SunspecBattery extends BaseSunspecDevice {
|
|
|
1752
1777
|
activeChargeLimitW: activeChargeLimitW,
|
|
1753
1778
|
activeDischargeLimitW: activeDischargeLimitW,
|
|
1754
1779
|
features,
|
|
1755
|
-
gridChargingEnabled:
|
|
1780
|
+
gridChargingEnabled: this.gridChargingEnabled(features),
|
|
1756
1781
|
...this.configuredBatteryMetadata()
|
|
1757
1782
|
}
|
|
1758
1783
|
});
|
|
@@ -1921,7 +1946,7 @@ export class SunspecBattery extends BaseSunspecDevice {
|
|
|
1921
1946
|
activeChargeLimitW: this.computeActiveChargeLimitW(batteryData),
|
|
1922
1947
|
activeDischargeLimitW: this.computeActiveDischargeLimitW(batteryData),
|
|
1923
1948
|
features,
|
|
1924
|
-
gridChargingEnabled:
|
|
1949
|
+
gridChargingEnabled: this.gridChargingEnabled(features),
|
|
1925
1950
|
...this.configuredBatteryMetadata()
|
|
1926
1951
|
}
|
|
1927
1952
|
});
|
|
@@ -2105,7 +2130,7 @@ export class SunspecBattery extends BaseSunspecDevice {
|
|
|
2105
2130
|
}
|
|
2106
2131
|
if (batteryData.inWRte >= 100)
|
|
2107
2132
|
return null;
|
|
2108
|
-
return (batteryData.wChaMax * batteryData.inWRte) / 100;
|
|
2133
|
+
return (batteryData.wChaMax * Math.max(0, batteryData.inWRte)) / 100;
|
|
2109
2134
|
}
|
|
2110
2135
|
/**
|
|
2111
2136
|
* Compute the currently active discharge limit in Watts from Model 124's
|
|
@@ -2118,7 +2143,8 @@ export class SunspecBattery extends BaseSunspecDevice {
|
|
|
2118
2143
|
}
|
|
2119
2144
|
if (batteryData.outWRte >= 100)
|
|
2120
2145
|
return null;
|
|
2121
|
-
|
|
2146
|
+
// A negative rate is a forced charge, not a negative limit: nothing may be discharged.
|
|
2147
|
+
return (batteryData.wChaMax * Math.max(0, batteryData.outWRte)) / 100;
|
|
2122
2148
|
}
|
|
2123
2149
|
determineStorageMode(controls) {
|
|
2124
2150
|
return deriveStorageMode(controls);
|
|
@@ -2160,6 +2186,7 @@ export class SunspecBattery extends BaseSunspecDevice {
|
|
|
2160
2186
|
sunspecClient: this.sunspecClient,
|
|
2161
2187
|
unitId: this.unitId,
|
|
2162
2188
|
getSnapshotService: () => this.snapshotService,
|
|
2189
|
+
gridChargeMethod: this.gridChargeMethod,
|
|
2163
2190
|
onErrorCallback: (err) => console.warn(`Battery ${this.applianceId}: schedule handler rejected input: ${err.message}`),
|
|
2164
2191
|
});
|
|
2165
2192
|
console.log(`Battery ${this.applianceId}: started data bus listening (listener ${this.dataBusListenerId})`);
|