@enyo-energy/sunspec-sdk 1.6.0 → 1.7.0
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/dist/cjs/sunspec-battery-feature-calibrator.cjs +5 -3
- package/dist/cjs/sunspec-battery-feature-calibrator.d.cts +4 -1
- package/dist/cjs/sunspec-battery-grid-charge.cjs +32 -0
- package/dist/cjs/sunspec-battery-grid-charge.d.cts +9 -0
- package/dist/cjs/sunspec-battery-schedule-handler.cjs +6 -6
- package/dist/cjs/sunspec-battery-schedule-handler.d.cts +4 -1
- package/dist/cjs/sunspec-devices.cjs +36 -9
- package/dist/cjs/sunspec-devices.d.cts +15 -2
- package/dist/cjs/sunspec-interfaces.cjs +20 -1
- package/dist/cjs/sunspec-interfaces.d.cts +23 -0
- package/dist/cjs/version.cjs +1 -1
- package/dist/cjs/version.d.cts +1 -1
- package/dist/sunspec-battery-feature-calibrator.d.ts +4 -1
- package/dist/sunspec-battery-feature-calibrator.js +6 -4
- package/dist/sunspec-battery-grid-charge.d.ts +9 -0
- package/dist/sunspec-battery-grid-charge.js +28 -0
- package/dist/sunspec-battery-schedule-handler.d.ts +4 -1
- package/dist/sunspec-battery-schedule-handler.js +7 -7
- package/dist/sunspec-devices.d.ts +15 -2
- package/dist/sunspec-devices.js +37 -10
- package/dist/sunspec-interfaces.d.ts +23 -0
- package/dist/sunspec-interfaces.js +19 -0
- package/dist/version.d.ts +1 -1
- package/dist/version.js +1 -1
- package/package.json +2 -2
|
@@ -4,6 +4,7 @@ exports.SunspecBatteryFeatureCalibrator = void 0;
|
|
|
4
4
|
exports.decodeFeatureResults = decodeFeatureResults;
|
|
5
5
|
const appliance_calibration_1 = require("@enyo-energy/appliance-calibration");
|
|
6
6
|
const enyo_battery_appliance_js_1 = require("@enyo-energy/energy-app-sdk/dist/types/enyo-battery-appliance.js");
|
|
7
|
+
const sunspec_battery_grid_charge_js_1 = require("./sunspec-battery-grid-charge.cjs");
|
|
7
8
|
const sunspec_interfaces_js_1 = require("./sunspec-interfaces.cjs");
|
|
8
9
|
/**
|
|
9
10
|
* SoC band each probe needs to operate in. Outside the band the probe returns
|
|
@@ -57,6 +58,7 @@ class SunspecBatteryFeatureCalibrator extends appliance_calibration_1.BatteryCal
|
|
|
57
58
|
sunspecClient;
|
|
58
59
|
unitId;
|
|
59
60
|
readBatteryData;
|
|
61
|
+
gridChargeMethod;
|
|
60
62
|
probeConfig;
|
|
61
63
|
probeClock;
|
|
62
64
|
// Local refs to the same instances the parent stores privately. We keep
|
|
@@ -71,6 +73,7 @@ class SunspecBatteryFeatureCalibrator extends appliance_calibration_1.BatteryCal
|
|
|
71
73
|
this.sunspecClient = options.sunspecClient;
|
|
72
74
|
this.unitId = options.unitId;
|
|
73
75
|
this.readBatteryData = options.readBatteryData;
|
|
76
|
+
this.gridChargeMethod = options.gridChargeMethod ?? sunspec_interfaces_js_1.SunspecGridChargeMethod.ChargeRateLimit;
|
|
74
77
|
this.probeConfig = { ...appliance_calibration_1.DEFAULT_BATTERY_CALIBRATOR_CONFIG, ...options.config };
|
|
75
78
|
this.probeSnapshotService = options.snapshotService;
|
|
76
79
|
this.probeResultStore = options.resultStore;
|
|
@@ -161,11 +164,10 @@ class SunspecBatteryFeatureCalibrator extends appliance_calibration_1.BatteryCal
|
|
|
161
164
|
}
|
|
162
165
|
const baselineBatW = this.sunspecDriver.readBatteryPowerW() ?? 0;
|
|
163
166
|
const baselineGridW = this.sunspecDriver.readGridPowerW() ?? 0;
|
|
167
|
+
// wChaMax is lowered to the test power, so a 100 % rate charges at exactly testPowerW.
|
|
164
168
|
const wrote = await this.sunspecClient.writeBatteryControls(this.unitId, {
|
|
165
|
-
chaGriSet: sunspec_interfaces_js_1.SunspecChargeSource.GRID,
|
|
166
169
|
wChaMax: this.probeConfig.testPowerW,
|
|
167
|
-
|
|
168
|
-
storCtlMod: sunspec_interfaces_js_1.SunspecStorageControlMode.CHARGE,
|
|
170
|
+
...(0, sunspec_battery_grid_charge_js_1.gridChargeControls)(this.gridChargeMethod, 100),
|
|
169
171
|
});
|
|
170
172
|
if (!wrote) {
|
|
171
173
|
return { verdict: 'failed', note: 'writeBatteryControls returned false for grid charge' };
|
|
@@ -1,12 +1,14 @@
|
|
|
1
1
|
import { BatteryCalibrator, type BatteryCalibratorOptions, type CalibrationResult } from "@enyo-energy/appliance-calibration";
|
|
2
2
|
import { EnyoBatteryFeature } from "@enyo-energy/energy-app-sdk/dist/types/enyo-battery-appliance.js";
|
|
3
3
|
import { BatteryControlsClient } from "./sunspec-battery-schedule-handler.cjs";
|
|
4
|
-
import { type SunspecBatteryControls, type SunspecBatteryData } from "./sunspec-interfaces.cjs";
|
|
4
|
+
import { type SunspecBatteryControls, type SunspecBatteryData, SunspecGridChargeMethod } from "./sunspec-interfaces.cjs";
|
|
5
5
|
export interface SunspecBatteryFeatureCalibratorOptions extends BatteryCalibratorOptions<SunspecBatteryControls> {
|
|
6
6
|
sunspecClient: BatteryControlsClient;
|
|
7
7
|
unitId: number;
|
|
8
8
|
/** Pulls the latest battery data so the orchestrator can pre-check SoC. */
|
|
9
9
|
readBatteryData: () => Promise<SunspecBatteryData | null>;
|
|
10
|
+
/** Register form the grid-charge probe tests; must match the schedule handler's. Defaults to ChargeRateLimit. */
|
|
11
|
+
gridChargeMethod?: SunspecGridChargeMethod;
|
|
10
12
|
}
|
|
11
13
|
/**
|
|
12
14
|
* SunSpec-specific calibrator that exercises each of the four controllable
|
|
@@ -48,6 +50,7 @@ export declare class SunspecBatteryFeatureCalibrator extends BatteryCalibrator<S
|
|
|
48
50
|
private readonly sunspecClient;
|
|
49
51
|
private readonly unitId;
|
|
50
52
|
private readonly readBatteryData;
|
|
53
|
+
private readonly gridChargeMethod;
|
|
51
54
|
private readonly probeConfig;
|
|
52
55
|
private readonly probeClock;
|
|
53
56
|
private readonly probeSnapshotService;
|
|
@@ -0,0 +1,32 @@
|
|
|
1
|
+
"use strict";
|
|
2
|
+
Object.defineProperty(exports, "__esModule", { value: true });
|
|
3
|
+
exports.gridChargeControls = gridChargeControls;
|
|
4
|
+
exports.gridChargeFields = gridChargeFields;
|
|
5
|
+
const sunspec_interfaces_js_1 = require("./sunspec-interfaces.cjs");
|
|
6
|
+
/**
|
|
7
|
+
* The Model 124 register set that charges the battery from the grid at `ratePct` of `WChaMax`,
|
|
8
|
+
* in the form the device acts on — see {@link SunspecGridChargeMethod}. Shared by the schedule
|
|
9
|
+
* handler and the calibrator's grid-charge probe, so the probe tests the write production uses.
|
|
10
|
+
*/
|
|
11
|
+
function gridChargeControls(method, ratePct) {
|
|
12
|
+
switch (method) {
|
|
13
|
+
case sunspec_interfaces_js_1.SunspecGridChargeMethod.ChargeRateLimit:
|
|
14
|
+
return {
|
|
15
|
+
chaGriSet: sunspec_interfaces_js_1.SunspecChargeSource.GRID,
|
|
16
|
+
inWRte: ratePct,
|
|
17
|
+
storCtlMod: sunspec_interfaces_js_1.SunspecStorageControlMode.CHARGE,
|
|
18
|
+
};
|
|
19
|
+
case sunspec_interfaces_js_1.SunspecGridChargeMethod.NegativeDischargeRate:
|
|
20
|
+
return {
|
|
21
|
+
chaGriSet: sunspec_interfaces_js_1.SunspecChargeSource.GRID,
|
|
22
|
+
inWRte: 100,
|
|
23
|
+
outWRte: -ratePct,
|
|
24
|
+
storCtlMod: sunspec_interfaces_js_1.SunspecStorageControlMode.DISCHARGE,
|
|
25
|
+
};
|
|
26
|
+
}
|
|
27
|
+
}
|
|
28
|
+
/** The fields {@link gridChargeControls} writes, for the snapshot service's modification record. */
|
|
29
|
+
function gridChargeFields(controls) {
|
|
30
|
+
const fields = ['chaGriSet', 'inWRte', 'outWRte', 'storCtlMod'];
|
|
31
|
+
return fields.filter(field => controls[field] !== undefined);
|
|
32
|
+
}
|
|
@@ -0,0 +1,9 @@
|
|
|
1
|
+
import { type SunspecBatteryControls, SunspecGridChargeMethod } from "./sunspec-interfaces.cjs";
|
|
2
|
+
/**
|
|
3
|
+
* The Model 124 register set that charges the battery from the grid at `ratePct` of `WChaMax`,
|
|
4
|
+
* in the form the device acts on — see {@link SunspecGridChargeMethod}. Shared by the schedule
|
|
5
|
+
* handler and the calibrator's grid-charge probe, so the probe tests the write production uses.
|
|
6
|
+
*/
|
|
7
|
+
export declare function gridChargeControls(method: SunspecGridChargeMethod, ratePct: number): Partial<SunspecBatteryControls>;
|
|
8
|
+
/** The fields {@link gridChargeControls} writes, for the snapshot service's modification record. */
|
|
9
|
+
export declare function gridChargeFields(controls: Partial<SunspecBatteryControls>): (keyof SunspecBatteryControls)[];
|
|
@@ -4,6 +4,7 @@ exports.SunspecBatteryScheduleHandler = void 0;
|
|
|
4
4
|
const storage_schedule_handler_js_1 = require("@enyo-energy/energy-app-sdk/dist/implementations/storage/storage-schedule-handler.js");
|
|
5
5
|
const enyo_data_bus_value_js_1 = require("@enyo-energy/energy-app-sdk/dist/types/enyo-data-bus-value.js");
|
|
6
6
|
const sunspec_interfaces_js_1 = require("./sunspec-interfaces.cjs");
|
|
7
|
+
const sunspec_battery_grid_charge_js_1 = require("./sunspec-battery-grid-charge.cjs");
|
|
7
8
|
/**
|
|
8
9
|
* How often the keepalive checks whether the active limit is due a refresh.
|
|
9
10
|
* The refresh itself happens every third of the revert timeout; this only
|
|
@@ -23,6 +24,7 @@ class SunspecBatteryScheduleHandler extends storage_schedule_handler_js_1.Storag
|
|
|
23
24
|
applianceIdForLog;
|
|
24
25
|
getSnapshotService;
|
|
25
26
|
onErrorCallback;
|
|
27
|
+
gridChargeMethod;
|
|
26
28
|
installedWChaMax;
|
|
27
29
|
/**
|
|
28
30
|
* Sticky pre-schedule snapshot, captured once on the first `onInit` and
|
|
@@ -73,6 +75,7 @@ class SunspecBatteryScheduleHandler extends storage_schedule_handler_js_1.Storag
|
|
|
73
75
|
this.applianceIdForLog = opts.applianceId;
|
|
74
76
|
this.getSnapshotService = opts.getSnapshotService;
|
|
75
77
|
this.onErrorCallback = opts.onErrorCallback;
|
|
78
|
+
this.gridChargeMethod = opts.gridChargeMethod ?? sunspec_interfaces_js_1.SunspecGridChargeMethod.ChargeRateLimit;
|
|
76
79
|
this.interval = opts.interval;
|
|
77
80
|
this.clock = opts.now ?? (() => Date.now());
|
|
78
81
|
}
|
|
@@ -295,12 +298,9 @@ class SunspecBatteryScheduleHandler extends storage_schedule_handler_js_1.Storag
|
|
|
295
298
|
}
|
|
296
299
|
const pct = Math.min(100, Math.max(0, (powerW / baseline) * 100));
|
|
297
300
|
if (direction === enyo_data_bus_value_js_1.EnyoStorageScheduleDirectionEnum.Charge) {
|
|
298
|
-
|
|
299
|
-
|
|
300
|
-
|
|
301
|
-
storCtlMod: sunspec_interfaces_js_1.SunspecStorageControlMode.CHARGE,
|
|
302
|
-
});
|
|
303
|
-
await this.getSnapshotService()?.recordModification(['chaGriSet', 'inWRte', 'storCtlMod']);
|
|
301
|
+
const controls = (0, sunspec_battery_grid_charge_js_1.gridChargeControls)(this.gridChargeMethod, pct);
|
|
302
|
+
await this.sunspecClient.writeBatteryControls(this.unitId, controls);
|
|
303
|
+
await this.getSnapshotService()?.recordModification((0, sunspec_battery_grid_charge_js_1.gridChargeFields)(controls));
|
|
304
304
|
}
|
|
305
305
|
else {
|
|
306
306
|
await this.sunspecClient.writeBatteryControls(this.unitId, {
|
|
@@ -1,7 +1,7 @@
|
|
|
1
1
|
import { StorageScheduleHandler, type ActiveStorageScheduleEntry, type StorageScheduleHandlerOptions } from "@enyo-energy/energy-app-sdk/dist/implementations/storage/storage-schedule-handler.js";
|
|
2
2
|
import { type EnyoDataBusSetStorageScheduleV1 } from "@enyo-energy/energy-app-sdk/dist/types/enyo-data-bus-value.js";
|
|
3
3
|
import { type SnapshotService } from "@enyo-energy/appliance-calibration";
|
|
4
|
-
import { type SunspecBatteryControls } from "./sunspec-interfaces.cjs";
|
|
4
|
+
import { type SunspecBatteryControls, SunspecGridChargeMethod } from "./sunspec-interfaces.cjs";
|
|
5
5
|
/**
|
|
6
6
|
* Narrow interface covering only the modbus reads/writes the schedule handler
|
|
7
7
|
* needs. The full `SunspecModbusClient` structurally satisfies this; pinning
|
|
@@ -47,6 +47,8 @@ export interface SunspecBatteryScheduleHandlerOptions extends StorageScheduleHan
|
|
|
47
47
|
/** Lazy so the snapshot service can be initialised after the handler. */
|
|
48
48
|
getSnapshotService: () => BatteryModificationRecorder | undefined;
|
|
49
49
|
onErrorCallback?: (err: Error) => void;
|
|
50
|
+
/** Register form of a Charge entry. Defaults to {@link SunspecGridChargeMethod.ChargeRateLimit}. */
|
|
51
|
+
gridChargeMethod?: SunspecGridChargeMethod;
|
|
50
52
|
}
|
|
51
53
|
/**
|
|
52
54
|
* Concrete `StorageScheduleHandler` for SunSpec Model 124 batteries. The base
|
|
@@ -61,6 +63,7 @@ export declare class SunspecBatteryScheduleHandler extends StorageScheduleHandle
|
|
|
61
63
|
private readonly applianceIdForLog;
|
|
62
64
|
private readonly getSnapshotService;
|
|
63
65
|
private readonly onErrorCallback?;
|
|
66
|
+
private readonly gridChargeMethod;
|
|
64
67
|
private installedWChaMax;
|
|
65
68
|
/**
|
|
66
69
|
* Sticky pre-schedule snapshot, captured once on the first `onInit` and
|
|
@@ -1518,6 +1518,14 @@ function deriveStorageMode(controls) {
|
|
|
1518
1518
|
if (chargeLimited && dischargeLimited && controls.inWRte === 0 && controls.outWRte === 0) {
|
|
1519
1519
|
return sunspec_interfaces_js_1.SunspecStorageMode.HOLDING;
|
|
1520
1520
|
}
|
|
1521
|
+
// A limit below zero reverses its direction: a negative discharge rate is a forced charge
|
|
1522
|
+
// (SunspecGridChargeMethod.NegativeDischargeRate), a negative charge rate a forced discharge.
|
|
1523
|
+
if (dischargeLimited && controls.outWRte !== undefined && controls.outWRte < 0) {
|
|
1524
|
+
return sunspec_interfaces_js_1.SunspecStorageMode.CHARGE;
|
|
1525
|
+
}
|
|
1526
|
+
if (chargeLimited && controls.inWRte !== undefined && controls.inWRte < 0) {
|
|
1527
|
+
return sunspec_interfaces_js_1.SunspecStorageMode.DISCHARGE;
|
|
1528
|
+
}
|
|
1521
1529
|
return dischargeLimited && !chargeLimited
|
|
1522
1530
|
? sunspec_interfaces_js_1.SunspecStorageMode.DISCHARGE
|
|
1523
1531
|
: sunspec_interfaces_js_1.SunspecStorageMode.CHARGE;
|
|
@@ -1540,6 +1548,8 @@ class SunspecBattery extends BaseSunspecDevice {
|
|
|
1540
1548
|
batteryCalibrator;
|
|
1541
1549
|
calibrationResultStore;
|
|
1542
1550
|
scheduleHandler;
|
|
1551
|
+
/** Register form of a grid charge, for both the schedule handler and the calibration probe. */
|
|
1552
|
+
gridChargeMethod;
|
|
1543
1553
|
/**
|
|
1544
1554
|
* Battery features that imply outbound control writes from the host action-taker.
|
|
1545
1555
|
* These are stripped from `appliance.battery.features` until the calibration result
|
|
@@ -1553,13 +1563,14 @@ class SunspecBattery extends BaseSunspecDevice {
|
|
|
1553
1563
|
enyo_battery_appliance_js_1.EnyoBatteryFeature.DischargeLimitation,
|
|
1554
1564
|
];
|
|
1555
1565
|
constructor(energyApp, name, networkDevice, sunspecClient, applianceManager, featureMode, unitId = 1, port = 502, baseAddress = 40000, capabilities = [], retryConfig, appliance, useTls,
|
|
1556
|
-
// Battery facts no register carries (
|
|
1557
|
-
//
|
|
1558
|
-
|
|
1566
|
+
// Battery facts no register carries (forwarded onto `appliance.battery` on connect;
|
|
1567
|
+
// see SunspecBatteryMetadataConfig) plus how the device is driven.
|
|
1568
|
+
config = {}) {
|
|
1559
1569
|
super(energyApp, name, networkDevice, sunspecClient, applianceManager, unitId, port, baseAddress, retryConfig, appliance, useTls);
|
|
1560
1570
|
this.featureMode = featureMode;
|
|
1561
1571
|
this.capabilities = capabilities;
|
|
1562
|
-
this.roundTripEfficiencyPercent =
|
|
1572
|
+
this.roundTripEfficiencyPercent = config.roundTripEfficiencyPercent;
|
|
1573
|
+
this.gridChargeMethod = config.gridChargeMethod ?? sunspec_interfaces_js_1.SunspecGridChargeMethod.ChargeRateLimit;
|
|
1563
1574
|
}
|
|
1564
1575
|
/**
|
|
1565
1576
|
* Last known round-trip efficiency, seeded from the constructor config and replaceable at
|
|
@@ -1606,6 +1617,19 @@ class SunspecBattery extends BaseSunspecDevice {
|
|
|
1606
1617
|
? {}
|
|
1607
1618
|
: { roundTripEfficiencyPercent: this.roundTripEfficiencyPercent };
|
|
1608
1619
|
}
|
|
1620
|
+
/**
|
|
1621
|
+
* Whether the host may charge this battery from the grid. Follows the advertised
|
|
1622
|
+
* `GridCharging` feature, NOT the live `chaGriSet` register: our own schedule handler
|
|
1623
|
+
* writes GRID on every Charge and PV on Discharge/Auto, so the register only says
|
|
1624
|
+
* whether we are grid-charging right now. Publishing it made the flag `false` whenever
|
|
1625
|
+
* the pack sat on Auto (all night), and enyo-control honours an explicit `false` by
|
|
1626
|
+
* planning no buys at all (ENY-1241). The value is always set, never omitted, because
|
|
1627
|
+
* `updateAppliance` merges `battery` and would otherwise keep a stale `false`.
|
|
1628
|
+
* The live register stays available through {@link isGridChargingEnabled}.
|
|
1629
|
+
*/
|
|
1630
|
+
gridChargingEnabled(features) {
|
|
1631
|
+
return features.includes(enyo_battery_appliance_js_1.EnyoBatteryFeature.GridCharging);
|
|
1632
|
+
}
|
|
1609
1633
|
/**
|
|
1610
1634
|
* Wire the battery into `@enyo-energy/appliance-calibration`'s
|
|
1611
1635
|
* `BatteryCalibrator` test-charge flow. Call once after {@link connect}.
|
|
@@ -1640,6 +1664,7 @@ class SunspecBattery extends BaseSunspecDevice {
|
|
|
1640
1664
|
sunspecClient: this.sunspecClient,
|
|
1641
1665
|
unitId: this.unitId,
|
|
1642
1666
|
readBatteryData: () => this.sunspecClient.readBatteryData(this.unitId),
|
|
1667
|
+
gridChargeMethod: this.gridChargeMethod,
|
|
1643
1668
|
snapshotService: this.snapshotService,
|
|
1644
1669
|
resultStore: opts.resultStore,
|
|
1645
1670
|
config: opts.config,
|
|
@@ -1734,7 +1759,7 @@ class SunspecBattery extends BaseSunspecDevice {
|
|
|
1734
1759
|
activeChargeLimitW: activeChargeLimitW,
|
|
1735
1760
|
activeDischargeLimitW: activeDischargeLimitW,
|
|
1736
1761
|
features,
|
|
1737
|
-
gridChargingEnabled:
|
|
1762
|
+
gridChargingEnabled: this.gridChargingEnabled(features),
|
|
1738
1763
|
...this.configuredBatteryMetadata()
|
|
1739
1764
|
}
|
|
1740
1765
|
});
|
|
@@ -1763,7 +1788,7 @@ class SunspecBattery extends BaseSunspecDevice {
|
|
|
1763
1788
|
activeChargeLimitW: activeChargeLimitW,
|
|
1764
1789
|
activeDischargeLimitW: activeDischargeLimitW,
|
|
1765
1790
|
features,
|
|
1766
|
-
gridChargingEnabled:
|
|
1791
|
+
gridChargingEnabled: this.gridChargingEnabled(features),
|
|
1767
1792
|
...this.configuredBatteryMetadata()
|
|
1768
1793
|
}
|
|
1769
1794
|
});
|
|
@@ -1932,7 +1957,7 @@ class SunspecBattery extends BaseSunspecDevice {
|
|
|
1932
1957
|
activeChargeLimitW: this.computeActiveChargeLimitW(batteryData),
|
|
1933
1958
|
activeDischargeLimitW: this.computeActiveDischargeLimitW(batteryData),
|
|
1934
1959
|
features,
|
|
1935
|
-
gridChargingEnabled:
|
|
1960
|
+
gridChargingEnabled: this.gridChargingEnabled(features),
|
|
1936
1961
|
...this.configuredBatteryMetadata()
|
|
1937
1962
|
}
|
|
1938
1963
|
});
|
|
@@ -2116,7 +2141,7 @@ class SunspecBattery extends BaseSunspecDevice {
|
|
|
2116
2141
|
}
|
|
2117
2142
|
if (batteryData.inWRte >= 100)
|
|
2118
2143
|
return null;
|
|
2119
|
-
return (batteryData.wChaMax * batteryData.inWRte) / 100;
|
|
2144
|
+
return (batteryData.wChaMax * Math.max(0, batteryData.inWRte)) / 100;
|
|
2120
2145
|
}
|
|
2121
2146
|
/**
|
|
2122
2147
|
* Compute the currently active discharge limit in Watts from Model 124's
|
|
@@ -2129,7 +2154,8 @@ class SunspecBattery extends BaseSunspecDevice {
|
|
|
2129
2154
|
}
|
|
2130
2155
|
if (batteryData.outWRte >= 100)
|
|
2131
2156
|
return null;
|
|
2132
|
-
|
|
2157
|
+
// A negative rate is a forced charge, not a negative limit: nothing may be discharged.
|
|
2158
|
+
return (batteryData.wChaMax * Math.max(0, batteryData.outWRte)) / 100;
|
|
2133
2159
|
}
|
|
2134
2160
|
determineStorageMode(controls) {
|
|
2135
2161
|
return deriveStorageMode(controls);
|
|
@@ -2171,6 +2197,7 @@ class SunspecBattery extends BaseSunspecDevice {
|
|
|
2171
2197
|
sunspecClient: this.sunspecClient,
|
|
2172
2198
|
unitId: this.unitId,
|
|
2173
2199
|
getSnapshotService: () => this.snapshotService,
|
|
2200
|
+
gridChargeMethod: this.gridChargeMethod,
|
|
2174
2201
|
onErrorCallback: (err) => console.warn(`Battery ${this.applianceId}: schedule handler rejected input: ${err.message}`),
|
|
2175
2202
|
});
|
|
2176
2203
|
console.log(`Battery ${this.applianceId}: started data bus listening (listener ${this.dataBusListenerId})`);
|
|
@@ -1,4 +1,4 @@
|
|
|
1
|
-
import { type IRetryConfig, type SunspecBatteryBaseData, SunspecBatteryCapability, type SunspecBatteryControls, type SunspecBatteryData, type SunspecBatteryFeatureMode, type SunspecInverterData, SunspecInverterCapability, SunspecPvPowerSource, type SunspecInverterMetadataConfig, type
|
|
1
|
+
import { type IRetryConfig, type SunspecBatteryBaseData, SunspecBatteryCapability, type SunspecBatteryControls, type SunspecBatteryData, type SunspecBatteryFeatureMode, type SunspecInverterData, SunspecInverterCapability, SunspecPvPowerSource, type SunspecInverterMetadataConfig, type SunspecBatteryConfig, SunspecPvPowerOrigin, type SunspecInverterReading, type SunspecBatteryReading, SunspecMeterCapability, type SunspecMPPTData, SunspecStorageMode, type SunspecCustomDeviceConfig } from "./sunspec-interfaces.cjs";
|
|
2
2
|
import { ApplianceManager, EnergyApp } from "@enyo-energy/energy-app-sdk";
|
|
3
3
|
import { type EnyoAppliance, type EnyoApplianceErrorCode, EnyoApplianceName } from "@enyo-energy/energy-app-sdk/dist/types/enyo-appliance.js";
|
|
4
4
|
import { EnyoNetworkDevice } from "@enyo-energy/energy-app-sdk/dist/types/enyo-network-device.js";
|
|
@@ -557,6 +557,8 @@ export declare class SunspecBattery extends BaseSunspecDevice {
|
|
|
557
557
|
private batteryCalibrator?;
|
|
558
558
|
private calibrationResultStore?;
|
|
559
559
|
private scheduleHandler;
|
|
560
|
+
/** Register form of a grid charge, for both the schedule handler and the calibration probe. */
|
|
561
|
+
private readonly gridChargeMethod;
|
|
560
562
|
/**
|
|
561
563
|
* Battery features that imply outbound control writes from the host action-taker.
|
|
562
564
|
* These are stripped from `appliance.battery.features` until the calibration result
|
|
@@ -564,7 +566,7 @@ export declare class SunspecBattery extends BaseSunspecDevice {
|
|
|
564
566
|
* {@link computeAdvertisedFeatures}.
|
|
565
567
|
*/
|
|
566
568
|
private static readonly CONTROLLABLE_FEATURES;
|
|
567
|
-
constructor(energyApp: EnergyApp, name: EnyoApplianceName[], networkDevice: EnyoNetworkDevice, sunspecClient: SunspecModbusClient, applianceManager: ApplianceManager, featureMode: SunspecBatteryFeatureMode, unitId?: number, port?: number, baseAddress?: number, capabilities?: SunspecBatteryCapability[], retryConfig?: IRetryConfig, appliance?: EnyoAppliance, useTls?: boolean,
|
|
569
|
+
constructor(energyApp: EnergyApp, name: EnyoApplianceName[], networkDevice: EnyoNetworkDevice, sunspecClient: SunspecModbusClient, applianceManager: ApplianceManager, featureMode: SunspecBatteryFeatureMode, unitId?: number, port?: number, baseAddress?: number, capabilities?: SunspecBatteryCapability[], retryConfig?: IRetryConfig, appliance?: EnyoAppliance, useTls?: boolean, config?: SunspecBatteryConfig);
|
|
568
570
|
/**
|
|
569
571
|
* Last known round-trip efficiency, seeded from the constructor config and replaceable at
|
|
570
572
|
* runtime via {@link setRoundTripEfficiencyPercent}. Undefined = not yet known; the SDK then
|
|
@@ -587,6 +589,17 @@ export declare class SunspecBattery extends BaseSunspecDevice {
|
|
|
587
589
|
* Spreading an explicit `undefined` would erase a value the host set elsewhere.
|
|
588
590
|
*/
|
|
589
591
|
private configuredBatteryMetadata;
|
|
592
|
+
/**
|
|
593
|
+
* Whether the host may charge this battery from the grid. Follows the advertised
|
|
594
|
+
* `GridCharging` feature, NOT the live `chaGriSet` register: our own schedule handler
|
|
595
|
+
* writes GRID on every Charge and PV on Discharge/Auto, so the register only says
|
|
596
|
+
* whether we are grid-charging right now. Publishing it made the flag `false` whenever
|
|
597
|
+
* the pack sat on Auto (all night), and enyo-control honours an explicit `false` by
|
|
598
|
+
* planning no buys at all (ENY-1241). The value is always set, never omitted, because
|
|
599
|
+
* `updateAppliance` merges `battery` and would otherwise keep a stale `false`.
|
|
600
|
+
* The live register stays available through {@link isGridChargingEnabled}.
|
|
601
|
+
*/
|
|
602
|
+
private gridChargingEnabled;
|
|
590
603
|
/**
|
|
591
604
|
* Wire the battery into `@enyo-energy/appliance-calibration`'s
|
|
592
605
|
* `BatteryCalibrator` test-charge flow. Call once after {@link connect}.
|
|
@@ -3,7 +3,7 @@
|
|
|
3
3
|
* SunSpec block interfaces with block numbers
|
|
4
4
|
*/
|
|
5
5
|
Object.defineProperty(exports, "__esModule", { value: true });
|
|
6
|
-
exports.SUNSPEC_CONTROLLABLE_FEATURES = exports.SunspecMeterCapability = exports.SunspecBatteryFeatureModeKind = exports.SunspecBatteryCapability = exports.SunspecPvPowerOrigin = exports.SunspecPvPowerSource = exports.SunspecInverterCapability = exports.SunspecStorageMode = exports.SunspecChargeSource = exports.SunspecVArPctMode = exports.SunspecEnableControl = exports.SunspecConnectionControl = exports.MAX_BATTERY_RATE_REVERT_TIMEOUT_SECONDS = exports.MIN_BATTERY_RATE_REVERT_TIMEOUT_SECONDS = exports.DEFAULT_BATTERY_RATE_REVERT_TIMEOUT_SECONDS = exports.SunspecStorageControlMode = exports.SunspecBatteryEvent1 = exports.SunspecBatteryBankState = exports.SunspecBatteryType = exports.SunspecBatteryControlMode = exports.SunspecBatteryChargeState = exports.SunspecInverterOperatingState = exports.SunspecMPPTOperatingState = exports.SUNSPEC_CONNECTION_LOST_CODE = exports.SunspecInverterEvent1 = exports.SunspecModelId = exports.DEFAULT_MODBUS_RESILIENCE_CONFIG = exports.DEFAULT_RETRY_CONFIG = void 0;
|
|
6
|
+
exports.SUNSPEC_CONTROLLABLE_FEATURES = exports.SunspecMeterCapability = exports.SunspecBatteryFeatureModeKind = exports.SunspecGridChargeMethod = exports.SunspecBatteryCapability = exports.SunspecPvPowerOrigin = exports.SunspecPvPowerSource = exports.SunspecInverterCapability = exports.SunspecStorageMode = exports.SunspecChargeSource = exports.SunspecVArPctMode = exports.SunspecEnableControl = exports.SunspecConnectionControl = exports.MAX_BATTERY_RATE_REVERT_TIMEOUT_SECONDS = exports.MIN_BATTERY_RATE_REVERT_TIMEOUT_SECONDS = exports.DEFAULT_BATTERY_RATE_REVERT_TIMEOUT_SECONDS = exports.SunspecStorageControlMode = exports.SunspecBatteryEvent1 = exports.SunspecBatteryBankState = exports.SunspecBatteryType = exports.SunspecBatteryControlMode = exports.SunspecBatteryChargeState = exports.SunspecInverterOperatingState = exports.SunspecMPPTOperatingState = exports.SUNSPEC_CONNECTION_LOST_CODE = exports.SunspecInverterEvent1 = exports.SunspecModelId = exports.DEFAULT_MODBUS_RESILIENCE_CONFIG = exports.DEFAULT_RETRY_CONFIG = void 0;
|
|
7
7
|
const enyo_battery_appliance_js_1 = require("@enyo-energy/energy-app-sdk/dist/types/enyo-battery-appliance.js");
|
|
8
8
|
exports.DEFAULT_RETRY_CONFIG = {
|
|
9
9
|
phases: [
|
|
@@ -348,6 +348,25 @@ var SunspecBatteryCapability;
|
|
|
348
348
|
SunspecBatteryCapability["DischargeLimit"] = "discharge-limit";
|
|
349
349
|
SunspecBatteryCapability["ChargeLimit"] = "charge-limit";
|
|
350
350
|
})(SunspecBatteryCapability || (exports.SunspecBatteryCapability = SunspecBatteryCapability = {}));
|
|
351
|
+
/**
|
|
352
|
+
* How a Model 124 battery is made to charge from the grid. Vendors read the rate setpoints
|
|
353
|
+
* differently, so the host picks the form its hardware actually acts on.
|
|
354
|
+
*/
|
|
355
|
+
var SunspecGridChargeMethod;
|
|
356
|
+
(function (SunspecGridChargeMethod) {
|
|
357
|
+
/**
|
|
358
|
+
* StorCtl_Mod bit 0 + InWRte = the target rate. A charge-rate *cap* on devices that treat
|
|
359
|
+
* InWRte as a maximum: with no PV surplus, nothing is charged. The historical default.
|
|
360
|
+
*/
|
|
361
|
+
SunspecGridChargeMethod["ChargeRateLimit"] = "charge-rate-limit";
|
|
362
|
+
/**
|
|
363
|
+
* StorCtl_Mod bit 1 + a negative OutWRte (-rate %), InWRte opened to 100 %. A discharge limit
|
|
364
|
+
* below zero is a minimum charge rate, which forces the charge whatever the PV does. Required
|
|
365
|
+
* by Fronius GEN24, where the bit-0 form only caps PV charging (same writes as evcc's and the
|
|
366
|
+
* Home Assistant fronius_modbus integration's "charge from grid").
|
|
367
|
+
*/
|
|
368
|
+
SunspecGridChargeMethod["NegativeDischargeRate"] = "negative-discharge-rate";
|
|
369
|
+
})(SunspecGridChargeMethod || (exports.SunspecGridChargeMethod = SunspecGridChargeMethod = {}));
|
|
351
370
|
/**
|
|
352
371
|
* Selects how `SunspecBattery` populates `appliance.battery.features`.
|
|
353
372
|
*
|
|
@@ -977,6 +977,24 @@ export declare enum SunspecBatteryCapability {
|
|
|
977
977
|
DischargeLimit = "discharge-limit",
|
|
978
978
|
ChargeLimit = "charge-limit"
|
|
979
979
|
}
|
|
980
|
+
/**
|
|
981
|
+
* How a Model 124 battery is made to charge from the grid. Vendors read the rate setpoints
|
|
982
|
+
* differently, so the host picks the form its hardware actually acts on.
|
|
983
|
+
*/
|
|
984
|
+
export declare enum SunspecGridChargeMethod {
|
|
985
|
+
/**
|
|
986
|
+
* StorCtl_Mod bit 0 + InWRte = the target rate. A charge-rate *cap* on devices that treat
|
|
987
|
+
* InWRte as a maximum: with no PV surplus, nothing is charged. The historical default.
|
|
988
|
+
*/
|
|
989
|
+
ChargeRateLimit = "charge-rate-limit",
|
|
990
|
+
/**
|
|
991
|
+
* StorCtl_Mod bit 1 + a negative OutWRte (-rate %), InWRte opened to 100 %. A discharge limit
|
|
992
|
+
* below zero is a minimum charge rate, which forces the charge whatever the PV does. Required
|
|
993
|
+
* by Fronius GEN24, where the bit-0 form only caps PV charging (same writes as evcc's and the
|
|
994
|
+
* Home Assistant fronius_modbus integration's "charge from grid").
|
|
995
|
+
*/
|
|
996
|
+
NegativeDischargeRate = "negative-discharge-rate"
|
|
997
|
+
}
|
|
980
998
|
/**
|
|
981
999
|
* Battery facts that live outside the SunSpec register map, published onto `appliance.battery` when
|
|
982
1000
|
* the device connects. Fields left `undefined` are not written, so an existing value in the
|
|
@@ -996,6 +1014,11 @@ export interface SunspecBatteryMetadataConfig {
|
|
|
996
1014
|
*/
|
|
997
1015
|
roundTripEfficiencyPercent?: number;
|
|
998
1016
|
}
|
|
1017
|
+
/** Per-battery configuration: the published metadata plus how the device is driven. */
|
|
1018
|
+
export interface SunspecBatteryConfig extends SunspecBatteryMetadataConfig {
|
|
1019
|
+
/** Register form for a grid charge. Defaults to {@link SunspecGridChargeMethod.ChargeRateLimit}. */
|
|
1020
|
+
gridChargeMethod?: SunspecGridChargeMethod;
|
|
1021
|
+
}
|
|
999
1022
|
/**
|
|
1000
1023
|
* Selects how `SunspecBattery` populates `appliance.battery.features`.
|
|
1001
1024
|
*
|
package/dist/cjs/version.cjs
CHANGED
package/dist/cjs/version.d.cts
CHANGED
|
@@ -1,12 +1,14 @@
|
|
|
1
1
|
import { BatteryCalibrator, type BatteryCalibratorOptions, type CalibrationResult } from "@enyo-energy/appliance-calibration";
|
|
2
2
|
import { EnyoBatteryFeature } from "@enyo-energy/energy-app-sdk/dist/types/enyo-battery-appliance.js";
|
|
3
3
|
import { BatteryControlsClient } from "./sunspec-battery-schedule-handler.js";
|
|
4
|
-
import { type SunspecBatteryControls, type SunspecBatteryData } from "./sunspec-interfaces.js";
|
|
4
|
+
import { type SunspecBatteryControls, type SunspecBatteryData, SunspecGridChargeMethod } from "./sunspec-interfaces.js";
|
|
5
5
|
export interface SunspecBatteryFeatureCalibratorOptions extends BatteryCalibratorOptions<SunspecBatteryControls> {
|
|
6
6
|
sunspecClient: BatteryControlsClient;
|
|
7
7
|
unitId: number;
|
|
8
8
|
/** Pulls the latest battery data so the orchestrator can pre-check SoC. */
|
|
9
9
|
readBatteryData: () => Promise<SunspecBatteryData | null>;
|
|
10
|
+
/** Register form the grid-charge probe tests; must match the schedule handler's. Defaults to ChargeRateLimit. */
|
|
11
|
+
gridChargeMethod?: SunspecGridChargeMethod;
|
|
10
12
|
}
|
|
11
13
|
/**
|
|
12
14
|
* SunSpec-specific calibrator that exercises each of the four controllable
|
|
@@ -48,6 +50,7 @@ export declare class SunspecBatteryFeatureCalibrator extends BatteryCalibrator<S
|
|
|
48
50
|
private readonly sunspecClient;
|
|
49
51
|
private readonly unitId;
|
|
50
52
|
private readonly readBatteryData;
|
|
53
|
+
private readonly gridChargeMethod;
|
|
51
54
|
private readonly probeConfig;
|
|
52
55
|
private readonly probeClock;
|
|
53
56
|
private readonly probeSnapshotService;
|
|
@@ -1,6 +1,7 @@
|
|
|
1
1
|
import { BatteryCalibrator, DEFAULT_BATTERY_CALIBRATOR_CONFIG, } from "@enyo-energy/appliance-calibration";
|
|
2
2
|
import { EnyoBatteryFeature } from "@enyo-energy/energy-app-sdk/dist/types/enyo-battery-appliance.js";
|
|
3
|
-
import {
|
|
3
|
+
import { gridChargeControls } from "./sunspec-battery-grid-charge.js";
|
|
4
|
+
import { SUNSPEC_CONTROLLABLE_FEATURES, SunspecChargeSource, SunspecGridChargeMethod, SunspecStorageControlMode, } from "./sunspec-interfaces.js";
|
|
4
5
|
/**
|
|
5
6
|
* SoC band each probe needs to operate in. Outside the band the probe returns
|
|
6
7
|
* `not-supported` instead of running — there's no useful signal when the
|
|
@@ -53,6 +54,7 @@ export class SunspecBatteryFeatureCalibrator extends BatteryCalibrator {
|
|
|
53
54
|
sunspecClient;
|
|
54
55
|
unitId;
|
|
55
56
|
readBatteryData;
|
|
57
|
+
gridChargeMethod;
|
|
56
58
|
probeConfig;
|
|
57
59
|
probeClock;
|
|
58
60
|
// Local refs to the same instances the parent stores privately. We keep
|
|
@@ -67,6 +69,7 @@ export class SunspecBatteryFeatureCalibrator extends BatteryCalibrator {
|
|
|
67
69
|
this.sunspecClient = options.sunspecClient;
|
|
68
70
|
this.unitId = options.unitId;
|
|
69
71
|
this.readBatteryData = options.readBatteryData;
|
|
72
|
+
this.gridChargeMethod = options.gridChargeMethod ?? SunspecGridChargeMethod.ChargeRateLimit;
|
|
70
73
|
this.probeConfig = { ...DEFAULT_BATTERY_CALIBRATOR_CONFIG, ...options.config };
|
|
71
74
|
this.probeSnapshotService = options.snapshotService;
|
|
72
75
|
this.probeResultStore = options.resultStore;
|
|
@@ -157,11 +160,10 @@ export class SunspecBatteryFeatureCalibrator extends BatteryCalibrator {
|
|
|
157
160
|
}
|
|
158
161
|
const baselineBatW = this.sunspecDriver.readBatteryPowerW() ?? 0;
|
|
159
162
|
const baselineGridW = this.sunspecDriver.readGridPowerW() ?? 0;
|
|
163
|
+
// wChaMax is lowered to the test power, so a 100 % rate charges at exactly testPowerW.
|
|
160
164
|
const wrote = await this.sunspecClient.writeBatteryControls(this.unitId, {
|
|
161
|
-
chaGriSet: SunspecChargeSource.GRID,
|
|
162
165
|
wChaMax: this.probeConfig.testPowerW,
|
|
163
|
-
|
|
164
|
-
storCtlMod: SunspecStorageControlMode.CHARGE,
|
|
166
|
+
...gridChargeControls(this.gridChargeMethod, 100),
|
|
165
167
|
});
|
|
166
168
|
if (!wrote) {
|
|
167
169
|
return { verdict: 'failed', note: 'writeBatteryControls returned false for grid charge' };
|
|
@@ -0,0 +1,9 @@
|
|
|
1
|
+
import { type SunspecBatteryControls, SunspecGridChargeMethod } from "./sunspec-interfaces.js";
|
|
2
|
+
/**
|
|
3
|
+
* The Model 124 register set that charges the battery from the grid at `ratePct` of `WChaMax`,
|
|
4
|
+
* in the form the device acts on — see {@link SunspecGridChargeMethod}. Shared by the schedule
|
|
5
|
+
* handler and the calibrator's grid-charge probe, so the probe tests the write production uses.
|
|
6
|
+
*/
|
|
7
|
+
export declare function gridChargeControls(method: SunspecGridChargeMethod, ratePct: number): Partial<SunspecBatteryControls>;
|
|
8
|
+
/** The fields {@link gridChargeControls} writes, for the snapshot service's modification record. */
|
|
9
|
+
export declare function gridChargeFields(controls: Partial<SunspecBatteryControls>): (keyof SunspecBatteryControls)[];
|
|
@@ -0,0 +1,28 @@
|
|
|
1
|
+
import { SunspecChargeSource, SunspecGridChargeMethod, SunspecStorageControlMode, } from "./sunspec-interfaces.js";
|
|
2
|
+
/**
|
|
3
|
+
* The Model 124 register set that charges the battery from the grid at `ratePct` of `WChaMax`,
|
|
4
|
+
* in the form the device acts on — see {@link SunspecGridChargeMethod}. Shared by the schedule
|
|
5
|
+
* handler and the calibrator's grid-charge probe, so the probe tests the write production uses.
|
|
6
|
+
*/
|
|
7
|
+
export function gridChargeControls(method, ratePct) {
|
|
8
|
+
switch (method) {
|
|
9
|
+
case SunspecGridChargeMethod.ChargeRateLimit:
|
|
10
|
+
return {
|
|
11
|
+
chaGriSet: SunspecChargeSource.GRID,
|
|
12
|
+
inWRte: ratePct,
|
|
13
|
+
storCtlMod: SunspecStorageControlMode.CHARGE,
|
|
14
|
+
};
|
|
15
|
+
case SunspecGridChargeMethod.NegativeDischargeRate:
|
|
16
|
+
return {
|
|
17
|
+
chaGriSet: SunspecChargeSource.GRID,
|
|
18
|
+
inWRte: 100,
|
|
19
|
+
outWRte: -ratePct,
|
|
20
|
+
storCtlMod: SunspecStorageControlMode.DISCHARGE,
|
|
21
|
+
};
|
|
22
|
+
}
|
|
23
|
+
}
|
|
24
|
+
/** The fields {@link gridChargeControls} writes, for the snapshot service's modification record. */
|
|
25
|
+
export function gridChargeFields(controls) {
|
|
26
|
+
const fields = ['chaGriSet', 'inWRte', 'outWRte', 'storCtlMod'];
|
|
27
|
+
return fields.filter(field => controls[field] !== undefined);
|
|
28
|
+
}
|
|
@@ -1,7 +1,7 @@
|
|
|
1
1
|
import { StorageScheduleHandler, type ActiveStorageScheduleEntry, type StorageScheduleHandlerOptions } from "@enyo-energy/energy-app-sdk/dist/implementations/storage/storage-schedule-handler.js";
|
|
2
2
|
import { type EnyoDataBusSetStorageScheduleV1 } from "@enyo-energy/energy-app-sdk/dist/types/enyo-data-bus-value.js";
|
|
3
3
|
import { type SnapshotService } from "@enyo-energy/appliance-calibration";
|
|
4
|
-
import { type SunspecBatteryControls } from "./sunspec-interfaces.js";
|
|
4
|
+
import { type SunspecBatteryControls, SunspecGridChargeMethod } from "./sunspec-interfaces.js";
|
|
5
5
|
/**
|
|
6
6
|
* Narrow interface covering only the modbus reads/writes the schedule handler
|
|
7
7
|
* needs. The full `SunspecModbusClient` structurally satisfies this; pinning
|
|
@@ -47,6 +47,8 @@ export interface SunspecBatteryScheduleHandlerOptions extends StorageScheduleHan
|
|
|
47
47
|
/** Lazy so the snapshot service can be initialised after the handler. */
|
|
48
48
|
getSnapshotService: () => BatteryModificationRecorder | undefined;
|
|
49
49
|
onErrorCallback?: (err: Error) => void;
|
|
50
|
+
/** Register form of a Charge entry. Defaults to {@link SunspecGridChargeMethod.ChargeRateLimit}. */
|
|
51
|
+
gridChargeMethod?: SunspecGridChargeMethod;
|
|
50
52
|
}
|
|
51
53
|
/**
|
|
52
54
|
* Concrete `StorageScheduleHandler` for SunSpec Model 124 batteries. The base
|
|
@@ -61,6 +63,7 @@ export declare class SunspecBatteryScheduleHandler extends StorageScheduleHandle
|
|
|
61
63
|
private readonly applianceIdForLog;
|
|
62
64
|
private readonly getSnapshotService;
|
|
63
65
|
private readonly onErrorCallback?;
|
|
66
|
+
private readonly gridChargeMethod;
|
|
64
67
|
private installedWChaMax;
|
|
65
68
|
/**
|
|
66
69
|
* Sticky pre-schedule snapshot, captured once on the first `onInit` and
|
|
@@ -1,6 +1,7 @@
|
|
|
1
1
|
import { StorageScheduleHandler, } from "@enyo-energy/energy-app-sdk/dist/implementations/storage/storage-schedule-handler.js";
|
|
2
2
|
import { EnyoStorageScheduleDirectionEnum, EnyoStorageScheduleModeEnum, } from "@enyo-energy/energy-app-sdk/dist/types/enyo-data-bus-value.js";
|
|
3
|
-
import { SunspecChargeSource, SunspecStorageControlMode, } from "./sunspec-interfaces.js";
|
|
3
|
+
import { SunspecChargeSource, SunspecGridChargeMethod, SunspecStorageControlMode, } from "./sunspec-interfaces.js";
|
|
4
|
+
import { gridChargeControls, gridChargeFields } from "./sunspec-battery-grid-charge.js";
|
|
4
5
|
/**
|
|
5
6
|
* How often the keepalive checks whether the active limit is due a refresh.
|
|
6
7
|
* The refresh itself happens every third of the revert timeout; this only
|
|
@@ -20,6 +21,7 @@ export class SunspecBatteryScheduleHandler extends StorageScheduleHandler {
|
|
|
20
21
|
applianceIdForLog;
|
|
21
22
|
getSnapshotService;
|
|
22
23
|
onErrorCallback;
|
|
24
|
+
gridChargeMethod;
|
|
23
25
|
installedWChaMax;
|
|
24
26
|
/**
|
|
25
27
|
* Sticky pre-schedule snapshot, captured once on the first `onInit` and
|
|
@@ -70,6 +72,7 @@ export class SunspecBatteryScheduleHandler extends StorageScheduleHandler {
|
|
|
70
72
|
this.applianceIdForLog = opts.applianceId;
|
|
71
73
|
this.getSnapshotService = opts.getSnapshotService;
|
|
72
74
|
this.onErrorCallback = opts.onErrorCallback;
|
|
75
|
+
this.gridChargeMethod = opts.gridChargeMethod ?? SunspecGridChargeMethod.ChargeRateLimit;
|
|
73
76
|
this.interval = opts.interval;
|
|
74
77
|
this.clock = opts.now ?? (() => Date.now());
|
|
75
78
|
}
|
|
@@ -292,12 +295,9 @@ export class SunspecBatteryScheduleHandler extends StorageScheduleHandler {
|
|
|
292
295
|
}
|
|
293
296
|
const pct = Math.min(100, Math.max(0, (powerW / baseline) * 100));
|
|
294
297
|
if (direction === EnyoStorageScheduleDirectionEnum.Charge) {
|
|
295
|
-
|
|
296
|
-
|
|
297
|
-
|
|
298
|
-
storCtlMod: SunspecStorageControlMode.CHARGE,
|
|
299
|
-
});
|
|
300
|
-
await this.getSnapshotService()?.recordModification(['chaGriSet', 'inWRte', 'storCtlMod']);
|
|
298
|
+
const controls = gridChargeControls(this.gridChargeMethod, pct);
|
|
299
|
+
await this.sunspecClient.writeBatteryControls(this.unitId, controls);
|
|
300
|
+
await this.getSnapshotService()?.recordModification(gridChargeFields(controls));
|
|
301
301
|
}
|
|
302
302
|
else {
|
|
303
303
|
await this.sunspecClient.writeBatteryControls(this.unitId, {
|
|
@@ -1,4 +1,4 @@
|
|
|
1
|
-
import { type IRetryConfig, type SunspecBatteryBaseData, SunspecBatteryCapability, type SunspecBatteryControls, type SunspecBatteryData, type SunspecBatteryFeatureMode, type SunspecInverterData, SunspecInverterCapability, SunspecPvPowerSource, type SunspecInverterMetadataConfig, type
|
|
1
|
+
import { type IRetryConfig, type SunspecBatteryBaseData, SunspecBatteryCapability, type SunspecBatteryControls, type SunspecBatteryData, type SunspecBatteryFeatureMode, type SunspecInverterData, SunspecInverterCapability, SunspecPvPowerSource, type SunspecInverterMetadataConfig, type SunspecBatteryConfig, SunspecPvPowerOrigin, type SunspecInverterReading, type SunspecBatteryReading, SunspecMeterCapability, type SunspecMPPTData, SunspecStorageMode, type SunspecCustomDeviceConfig } from "./sunspec-interfaces.js";
|
|
2
2
|
import { ApplianceManager, EnergyApp } from "@enyo-energy/energy-app-sdk";
|
|
3
3
|
import { type EnyoAppliance, type EnyoApplianceErrorCode, EnyoApplianceName } from "@enyo-energy/energy-app-sdk/dist/types/enyo-appliance.js";
|
|
4
4
|
import { EnyoNetworkDevice } from "@enyo-energy/energy-app-sdk/dist/types/enyo-network-device.js";
|
|
@@ -557,6 +557,8 @@ export declare class SunspecBattery extends BaseSunspecDevice {
|
|
|
557
557
|
private batteryCalibrator?;
|
|
558
558
|
private calibrationResultStore?;
|
|
559
559
|
private scheduleHandler;
|
|
560
|
+
/** Register form of a grid charge, for both the schedule handler and the calibration probe. */
|
|
561
|
+
private readonly gridChargeMethod;
|
|
560
562
|
/**
|
|
561
563
|
* Battery features that imply outbound control writes from the host action-taker.
|
|
562
564
|
* These are stripped from `appliance.battery.features` until the calibration result
|
|
@@ -564,7 +566,7 @@ export declare class SunspecBattery extends BaseSunspecDevice {
|
|
|
564
566
|
* {@link computeAdvertisedFeatures}.
|
|
565
567
|
*/
|
|
566
568
|
private static readonly CONTROLLABLE_FEATURES;
|
|
567
|
-
constructor(energyApp: EnergyApp, name: EnyoApplianceName[], networkDevice: EnyoNetworkDevice, sunspecClient: SunspecModbusClient, applianceManager: ApplianceManager, featureMode: SunspecBatteryFeatureMode, unitId?: number, port?: number, baseAddress?: number, capabilities?: SunspecBatteryCapability[], retryConfig?: IRetryConfig, appliance?: EnyoAppliance, useTls?: boolean,
|
|
569
|
+
constructor(energyApp: EnergyApp, name: EnyoApplianceName[], networkDevice: EnyoNetworkDevice, sunspecClient: SunspecModbusClient, applianceManager: ApplianceManager, featureMode: SunspecBatteryFeatureMode, unitId?: number, port?: number, baseAddress?: number, capabilities?: SunspecBatteryCapability[], retryConfig?: IRetryConfig, appliance?: EnyoAppliance, useTls?: boolean, config?: SunspecBatteryConfig);
|
|
568
570
|
/**
|
|
569
571
|
* Last known round-trip efficiency, seeded from the constructor config and replaceable at
|
|
570
572
|
* runtime via {@link setRoundTripEfficiencyPercent}. Undefined = not yet known; the SDK then
|
|
@@ -587,6 +589,17 @@ export declare class SunspecBattery extends BaseSunspecDevice {
|
|
|
587
589
|
* Spreading an explicit `undefined` would erase a value the host set elsewhere.
|
|
588
590
|
*/
|
|
589
591
|
private configuredBatteryMetadata;
|
|
592
|
+
/**
|
|
593
|
+
* Whether the host may charge this battery from the grid. Follows the advertised
|
|
594
|
+
* `GridCharging` feature, NOT the live `chaGriSet` register: our own schedule handler
|
|
595
|
+
* writes GRID on every Charge and PV on Discharge/Auto, so the register only says
|
|
596
|
+
* whether we are grid-charging right now. Publishing it made the flag `false` whenever
|
|
597
|
+
* the pack sat on Auto (all night), and enyo-control honours an explicit `false` by
|
|
598
|
+
* planning no buys at all (ENY-1241). The value is always set, never omitted, because
|
|
599
|
+
* `updateAppliance` merges `battery` and would otherwise keep a stale `false`.
|
|
600
|
+
* The live register stays available through {@link isGridChargingEnabled}.
|
|
601
|
+
*/
|
|
602
|
+
private gridChargingEnabled;
|
|
590
603
|
/**
|
|
591
604
|
* Wire the battery into `@enyo-energy/appliance-calibration`'s
|
|
592
605
|
* `BatteryCalibrator` test-charge flow. Call once after {@link connect}.
|
package/dist/sunspec-devices.js
CHANGED
|
@@ -1,4 +1,4 @@
|
|
|
1
|
-
import { SunspecBatteryChargeState, SunspecBatteryFeatureModeKind, SunspecEnableControl, SunspecInverterCapability, SunspecPvPowerSource, SunspecPvPowerOrigin, SunspecInverterEvent1, SunspecInverterOperatingState, SunspecModelId, SunspecMPPTOperatingState, SunspecStorageMode, SUNSPEC_CONNECTION_LOST_CODE } from "./sunspec-interfaces.js";
|
|
1
|
+
import { SunspecBatteryChargeState, SunspecBatteryFeatureModeKind, SunspecEnableControl, SunspecInverterCapability, SunspecPvPowerSource, SunspecGridChargeMethod, SunspecPvPowerOrigin, SunspecInverterEvent1, SunspecInverterOperatingState, SunspecModelId, SunspecMPPTOperatingState, SunspecStorageMode, SUNSPEC_CONNECTION_LOST_CODE } from "./sunspec-interfaces.js";
|
|
2
2
|
import { randomUUID } from "node:crypto";
|
|
3
3
|
import { EnyoApplianceConnectionType, EnyoApplianceStateEnum, EnyoApplianceStatusEnum, EnyoApplianceTopologyFeatureEnum, EnyoApplianceTypeEnum } from "@enyo-energy/energy-app-sdk/dist/types/enyo-appliance.js";
|
|
4
4
|
import { ConnectionRetryManager } from "./connection-retry-manager.js";
|
|
@@ -1507,6 +1507,14 @@ export function deriveStorageMode(controls) {
|
|
|
1507
1507
|
if (chargeLimited && dischargeLimited && controls.inWRte === 0 && controls.outWRte === 0) {
|
|
1508
1508
|
return SunspecStorageMode.HOLDING;
|
|
1509
1509
|
}
|
|
1510
|
+
// A limit below zero reverses its direction: a negative discharge rate is a forced charge
|
|
1511
|
+
// (SunspecGridChargeMethod.NegativeDischargeRate), a negative charge rate a forced discharge.
|
|
1512
|
+
if (dischargeLimited && controls.outWRte !== undefined && controls.outWRte < 0) {
|
|
1513
|
+
return SunspecStorageMode.CHARGE;
|
|
1514
|
+
}
|
|
1515
|
+
if (chargeLimited && controls.inWRte !== undefined && controls.inWRte < 0) {
|
|
1516
|
+
return SunspecStorageMode.DISCHARGE;
|
|
1517
|
+
}
|
|
1510
1518
|
return dischargeLimited && !chargeLimited
|
|
1511
1519
|
? SunspecStorageMode.DISCHARGE
|
|
1512
1520
|
: SunspecStorageMode.CHARGE;
|
|
@@ -1529,6 +1537,8 @@ export class SunspecBattery extends BaseSunspecDevice {
|
|
|
1529
1537
|
batteryCalibrator;
|
|
1530
1538
|
calibrationResultStore;
|
|
1531
1539
|
scheduleHandler;
|
|
1540
|
+
/** Register form of a grid charge, for both the schedule handler and the calibration probe. */
|
|
1541
|
+
gridChargeMethod;
|
|
1532
1542
|
/**
|
|
1533
1543
|
* Battery features that imply outbound control writes from the host action-taker.
|
|
1534
1544
|
* These are stripped from `appliance.battery.features` until the calibration result
|
|
@@ -1542,13 +1552,14 @@ export class SunspecBattery extends BaseSunspecDevice {
|
|
|
1542
1552
|
EnyoBatteryFeature.DischargeLimitation,
|
|
1543
1553
|
];
|
|
1544
1554
|
constructor(energyApp, name, networkDevice, sunspecClient, applianceManager, featureMode, unitId = 1, port = 502, baseAddress = 40000, capabilities = [], retryConfig, appliance, useTls,
|
|
1545
|
-
// Battery facts no register carries (
|
|
1546
|
-
//
|
|
1547
|
-
|
|
1555
|
+
// Battery facts no register carries (forwarded onto `appliance.battery` on connect;
|
|
1556
|
+
// see SunspecBatteryMetadataConfig) plus how the device is driven.
|
|
1557
|
+
config = {}) {
|
|
1548
1558
|
super(energyApp, name, networkDevice, sunspecClient, applianceManager, unitId, port, baseAddress, retryConfig, appliance, useTls);
|
|
1549
1559
|
this.featureMode = featureMode;
|
|
1550
1560
|
this.capabilities = capabilities;
|
|
1551
|
-
this.roundTripEfficiencyPercent =
|
|
1561
|
+
this.roundTripEfficiencyPercent = config.roundTripEfficiencyPercent;
|
|
1562
|
+
this.gridChargeMethod = config.gridChargeMethod ?? SunspecGridChargeMethod.ChargeRateLimit;
|
|
1552
1563
|
}
|
|
1553
1564
|
/**
|
|
1554
1565
|
* Last known round-trip efficiency, seeded from the constructor config and replaceable at
|
|
@@ -1595,6 +1606,19 @@ export class SunspecBattery extends BaseSunspecDevice {
|
|
|
1595
1606
|
? {}
|
|
1596
1607
|
: { roundTripEfficiencyPercent: this.roundTripEfficiencyPercent };
|
|
1597
1608
|
}
|
|
1609
|
+
/**
|
|
1610
|
+
* Whether the host may charge this battery from the grid. Follows the advertised
|
|
1611
|
+
* `GridCharging` feature, NOT the live `chaGriSet` register: our own schedule handler
|
|
1612
|
+
* writes GRID on every Charge and PV on Discharge/Auto, so the register only says
|
|
1613
|
+
* whether we are grid-charging right now. Publishing it made the flag `false` whenever
|
|
1614
|
+
* the pack sat on Auto (all night), and enyo-control honours an explicit `false` by
|
|
1615
|
+
* planning no buys at all (ENY-1241). The value is always set, never omitted, because
|
|
1616
|
+
* `updateAppliance` merges `battery` and would otherwise keep a stale `false`.
|
|
1617
|
+
* The live register stays available through {@link isGridChargingEnabled}.
|
|
1618
|
+
*/
|
|
1619
|
+
gridChargingEnabled(features) {
|
|
1620
|
+
return features.includes(EnyoBatteryFeature.GridCharging);
|
|
1621
|
+
}
|
|
1598
1622
|
/**
|
|
1599
1623
|
* Wire the battery into `@enyo-energy/appliance-calibration`'s
|
|
1600
1624
|
* `BatteryCalibrator` test-charge flow. Call once after {@link connect}.
|
|
@@ -1629,6 +1653,7 @@ export class SunspecBattery extends BaseSunspecDevice {
|
|
|
1629
1653
|
sunspecClient: this.sunspecClient,
|
|
1630
1654
|
unitId: this.unitId,
|
|
1631
1655
|
readBatteryData: () => this.sunspecClient.readBatteryData(this.unitId),
|
|
1656
|
+
gridChargeMethod: this.gridChargeMethod,
|
|
1632
1657
|
snapshotService: this.snapshotService,
|
|
1633
1658
|
resultStore: opts.resultStore,
|
|
1634
1659
|
config: opts.config,
|
|
@@ -1723,7 +1748,7 @@ export class SunspecBattery extends BaseSunspecDevice {
|
|
|
1723
1748
|
activeChargeLimitW: activeChargeLimitW,
|
|
1724
1749
|
activeDischargeLimitW: activeDischargeLimitW,
|
|
1725
1750
|
features,
|
|
1726
|
-
gridChargingEnabled:
|
|
1751
|
+
gridChargingEnabled: this.gridChargingEnabled(features),
|
|
1727
1752
|
...this.configuredBatteryMetadata()
|
|
1728
1753
|
}
|
|
1729
1754
|
});
|
|
@@ -1752,7 +1777,7 @@ export class SunspecBattery extends BaseSunspecDevice {
|
|
|
1752
1777
|
activeChargeLimitW: activeChargeLimitW,
|
|
1753
1778
|
activeDischargeLimitW: activeDischargeLimitW,
|
|
1754
1779
|
features,
|
|
1755
|
-
gridChargingEnabled:
|
|
1780
|
+
gridChargingEnabled: this.gridChargingEnabled(features),
|
|
1756
1781
|
...this.configuredBatteryMetadata()
|
|
1757
1782
|
}
|
|
1758
1783
|
});
|
|
@@ -1921,7 +1946,7 @@ export class SunspecBattery extends BaseSunspecDevice {
|
|
|
1921
1946
|
activeChargeLimitW: this.computeActiveChargeLimitW(batteryData),
|
|
1922
1947
|
activeDischargeLimitW: this.computeActiveDischargeLimitW(batteryData),
|
|
1923
1948
|
features,
|
|
1924
|
-
gridChargingEnabled:
|
|
1949
|
+
gridChargingEnabled: this.gridChargingEnabled(features),
|
|
1925
1950
|
...this.configuredBatteryMetadata()
|
|
1926
1951
|
}
|
|
1927
1952
|
});
|
|
@@ -2105,7 +2130,7 @@ export class SunspecBattery extends BaseSunspecDevice {
|
|
|
2105
2130
|
}
|
|
2106
2131
|
if (batteryData.inWRte >= 100)
|
|
2107
2132
|
return null;
|
|
2108
|
-
return (batteryData.wChaMax * batteryData.inWRte) / 100;
|
|
2133
|
+
return (batteryData.wChaMax * Math.max(0, batteryData.inWRte)) / 100;
|
|
2109
2134
|
}
|
|
2110
2135
|
/**
|
|
2111
2136
|
* Compute the currently active discharge limit in Watts from Model 124's
|
|
@@ -2118,7 +2143,8 @@ export class SunspecBattery extends BaseSunspecDevice {
|
|
|
2118
2143
|
}
|
|
2119
2144
|
if (batteryData.outWRte >= 100)
|
|
2120
2145
|
return null;
|
|
2121
|
-
|
|
2146
|
+
// A negative rate is a forced charge, not a negative limit: nothing may be discharged.
|
|
2147
|
+
return (batteryData.wChaMax * Math.max(0, batteryData.outWRte)) / 100;
|
|
2122
2148
|
}
|
|
2123
2149
|
determineStorageMode(controls) {
|
|
2124
2150
|
return deriveStorageMode(controls);
|
|
@@ -2160,6 +2186,7 @@ export class SunspecBattery extends BaseSunspecDevice {
|
|
|
2160
2186
|
sunspecClient: this.sunspecClient,
|
|
2161
2187
|
unitId: this.unitId,
|
|
2162
2188
|
getSnapshotService: () => this.snapshotService,
|
|
2189
|
+
gridChargeMethod: this.gridChargeMethod,
|
|
2163
2190
|
onErrorCallback: (err) => console.warn(`Battery ${this.applianceId}: schedule handler rejected input: ${err.message}`),
|
|
2164
2191
|
});
|
|
2165
2192
|
console.log(`Battery ${this.applianceId}: started data bus listening (listener ${this.dataBusListenerId})`);
|
|
@@ -977,6 +977,24 @@ export declare enum SunspecBatteryCapability {
|
|
|
977
977
|
DischargeLimit = "discharge-limit",
|
|
978
978
|
ChargeLimit = "charge-limit"
|
|
979
979
|
}
|
|
980
|
+
/**
|
|
981
|
+
* How a Model 124 battery is made to charge from the grid. Vendors read the rate setpoints
|
|
982
|
+
* differently, so the host picks the form its hardware actually acts on.
|
|
983
|
+
*/
|
|
984
|
+
export declare enum SunspecGridChargeMethod {
|
|
985
|
+
/**
|
|
986
|
+
* StorCtl_Mod bit 0 + InWRte = the target rate. A charge-rate *cap* on devices that treat
|
|
987
|
+
* InWRte as a maximum: with no PV surplus, nothing is charged. The historical default.
|
|
988
|
+
*/
|
|
989
|
+
ChargeRateLimit = "charge-rate-limit",
|
|
990
|
+
/**
|
|
991
|
+
* StorCtl_Mod bit 1 + a negative OutWRte (-rate %), InWRte opened to 100 %. A discharge limit
|
|
992
|
+
* below zero is a minimum charge rate, which forces the charge whatever the PV does. Required
|
|
993
|
+
* by Fronius GEN24, where the bit-0 form only caps PV charging (same writes as evcc's and the
|
|
994
|
+
* Home Assistant fronius_modbus integration's "charge from grid").
|
|
995
|
+
*/
|
|
996
|
+
NegativeDischargeRate = "negative-discharge-rate"
|
|
997
|
+
}
|
|
980
998
|
/**
|
|
981
999
|
* Battery facts that live outside the SunSpec register map, published onto `appliance.battery` when
|
|
982
1000
|
* the device connects. Fields left `undefined` are not written, so an existing value in the
|
|
@@ -996,6 +1014,11 @@ export interface SunspecBatteryMetadataConfig {
|
|
|
996
1014
|
*/
|
|
997
1015
|
roundTripEfficiencyPercent?: number;
|
|
998
1016
|
}
|
|
1017
|
+
/** Per-battery configuration: the published metadata plus how the device is driven. */
|
|
1018
|
+
export interface SunspecBatteryConfig extends SunspecBatteryMetadataConfig {
|
|
1019
|
+
/** Register form for a grid charge. Defaults to {@link SunspecGridChargeMethod.ChargeRateLimit}. */
|
|
1020
|
+
gridChargeMethod?: SunspecGridChargeMethod;
|
|
1021
|
+
}
|
|
999
1022
|
/**
|
|
1000
1023
|
* Selects how `SunspecBattery` populates `appliance.battery.features`.
|
|
1001
1024
|
*
|
|
@@ -345,6 +345,25 @@ export var SunspecBatteryCapability;
|
|
|
345
345
|
SunspecBatteryCapability["DischargeLimit"] = "discharge-limit";
|
|
346
346
|
SunspecBatteryCapability["ChargeLimit"] = "charge-limit";
|
|
347
347
|
})(SunspecBatteryCapability || (SunspecBatteryCapability = {}));
|
|
348
|
+
/**
|
|
349
|
+
* How a Model 124 battery is made to charge from the grid. Vendors read the rate setpoints
|
|
350
|
+
* differently, so the host picks the form its hardware actually acts on.
|
|
351
|
+
*/
|
|
352
|
+
export var SunspecGridChargeMethod;
|
|
353
|
+
(function (SunspecGridChargeMethod) {
|
|
354
|
+
/**
|
|
355
|
+
* StorCtl_Mod bit 0 + InWRte = the target rate. A charge-rate *cap* on devices that treat
|
|
356
|
+
* InWRte as a maximum: with no PV surplus, nothing is charged. The historical default.
|
|
357
|
+
*/
|
|
358
|
+
SunspecGridChargeMethod["ChargeRateLimit"] = "charge-rate-limit";
|
|
359
|
+
/**
|
|
360
|
+
* StorCtl_Mod bit 1 + a negative OutWRte (-rate %), InWRte opened to 100 %. A discharge limit
|
|
361
|
+
* below zero is a minimum charge rate, which forces the charge whatever the PV does. Required
|
|
362
|
+
* by Fronius GEN24, where the bit-0 form only caps PV charging (same writes as evcc's and the
|
|
363
|
+
* Home Assistant fronius_modbus integration's "charge from grid").
|
|
364
|
+
*/
|
|
365
|
+
SunspecGridChargeMethod["NegativeDischargeRate"] = "negative-discharge-rate";
|
|
366
|
+
})(SunspecGridChargeMethod || (SunspecGridChargeMethod = {}));
|
|
348
367
|
/**
|
|
349
368
|
* Selects how `SunspecBattery` populates `appliance.battery.features`.
|
|
350
369
|
*
|
package/dist/version.d.ts
CHANGED
package/dist/version.js
CHANGED
package/package.json
CHANGED
|
@@ -1,6 +1,6 @@
|
|
|
1
1
|
{
|
|
2
2
|
"name": "@enyo-energy/sunspec-sdk",
|
|
3
|
-
"version": "1.
|
|
3
|
+
"version": "1.7.0",
|
|
4
4
|
"description": "enyo Energy Sunspec SDK",
|
|
5
5
|
"type": "module",
|
|
6
6
|
"main": "dist/index.js",
|
|
@@ -41,7 +41,7 @@
|
|
|
41
41
|
},
|
|
42
42
|
"dependencies": {
|
|
43
43
|
"@enyo-energy/appliance-calibration": "0.0.3",
|
|
44
|
-
"@enyo-energy/energy-app-sdk": "1.
|
|
44
|
+
"@enyo-energy/energy-app-sdk": "1.40.0"
|
|
45
45
|
},
|
|
46
46
|
"volta": {
|
|
47
47
|
"node": "22.17.0"
|