@enyo-energy/sunspec-sdk 1.3.0 → 1.4.0
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/dist/cjs/sunspec-battery-schedule-handler.cjs +87 -3
- package/dist/cjs/sunspec-battery-schedule-handler.d.cts +30 -0
- package/dist/cjs/sunspec-devices.cjs +13 -0
- package/dist/cjs/sunspec-devices.d.cts +7 -0
- package/dist/cjs/sunspec-interfaces.cjs +23 -1
- package/dist/cjs/sunspec-interfaces.d.cts +22 -0
- package/dist/cjs/sunspec-modbus-client.cjs +66 -0
- package/dist/cjs/sunspec-modbus-client.d.cts +31 -0
- package/dist/cjs/version.cjs +1 -1
- package/dist/cjs/version.d.cts +1 -1
- package/dist/sunspec-battery-schedule-handler.d.ts +30 -0
- package/dist/sunspec-battery-schedule-handler.js +87 -3
- package/dist/sunspec-devices.d.ts +7 -0
- package/dist/sunspec-devices.js +13 -0
- package/dist/sunspec-interfaces.d.ts +22 -0
- package/dist/sunspec-interfaces.js +22 -0
- package/dist/sunspec-modbus-client.d.ts +31 -0
- package/dist/sunspec-modbus-client.js +67 -1
- package/dist/version.d.ts +1 -1
- package/dist/version.js +1 -1
- package/package.json +2 -2
|
@@ -4,6 +4,12 @@ exports.SunspecBatteryScheduleHandler = void 0;
|
|
|
4
4
|
const storage_schedule_handler_js_1 = require("@enyo-energy/energy-app-sdk/dist/implementations/storage/storage-schedule-handler.js");
|
|
5
5
|
const enyo_data_bus_value_js_1 = require("@enyo-energy/energy-app-sdk/dist/types/enyo-data-bus-value.js");
|
|
6
6
|
const sunspec_interfaces_js_1 = require("./sunspec-interfaces.cjs");
|
|
7
|
+
/**
|
|
8
|
+
* How often the keepalive checks whether the active limit is due a refresh.
|
|
9
|
+
* The refresh itself happens every third of the revert timeout; this only
|
|
10
|
+
* bounds how late it can be.
|
|
11
|
+
*/
|
|
12
|
+
const KEEPALIVE_CHECK_INTERVAL = '5s';
|
|
7
13
|
/**
|
|
8
14
|
* Concrete `StorageScheduleHandler` for SunSpec Model 124 batteries. The base
|
|
9
15
|
* class owns the data-bus subscription, the 1-second tick, schedule
|
|
@@ -41,6 +47,25 @@ class SunspecBatteryScheduleHandler extends storage_schedule_handler_js_1.Storag
|
|
|
41
47
|
* path can tell "released and gone" from "released and still live".
|
|
42
48
|
*/
|
|
43
49
|
isDisposed = false;
|
|
50
|
+
clock;
|
|
51
|
+
/**
|
|
52
|
+
* The Charge / Discharge entry currently enforced on the device, kept alive
|
|
53
|
+
* by {@link onKeepalive}. The battery is given an InOutWRte_RvrtTms on
|
|
54
|
+
* connect, so the device drops a limit nobody refreshes — which is the point
|
|
55
|
+
* when the hub is gone, but would also end a long entry early if the hub is
|
|
56
|
+
* alive and simply has nothing new to send. Undefined while idle / released.
|
|
57
|
+
*/
|
|
58
|
+
limitEntry;
|
|
59
|
+
lastLimitWriteAtMs = 0;
|
|
60
|
+
keepaliveIntervalId;
|
|
61
|
+
interval;
|
|
62
|
+
/**
|
|
63
|
+
* Every Model 124 write goes through this chain. Each write is several
|
|
64
|
+
* register transactions; a keepalive refresh interleaved with an entry
|
|
65
|
+
* transition could otherwise leave the old entry's rate under the new
|
|
66
|
+
* entry's mode.
|
|
67
|
+
*/
|
|
68
|
+
writeChain = Promise.resolve();
|
|
44
69
|
constructor(opts) {
|
|
45
70
|
super(opts);
|
|
46
71
|
this.sunspecClient = opts.sunspecClient;
|
|
@@ -48,6 +73,8 @@ class SunspecBatteryScheduleHandler extends storage_schedule_handler_js_1.Storag
|
|
|
48
73
|
this.applianceIdForLog = opts.applianceId;
|
|
49
74
|
this.getSnapshotService = opts.getSnapshotService;
|
|
50
75
|
this.onErrorCallback = opts.onErrorCallback;
|
|
76
|
+
this.interval = opts.interval;
|
|
77
|
+
this.clock = opts.now ?? (() => Date.now());
|
|
51
78
|
}
|
|
52
79
|
/**
|
|
53
80
|
* Override the base-class data-bus router so a schedule-to-schedule
|
|
@@ -92,13 +119,14 @@ class SunspecBatteryScheduleHandler extends storage_schedule_handler_js_1.Storag
|
|
|
92
119
|
// Writing the release unconditionally is safe because it is
|
|
93
120
|
// idempotent: it is exactly the register set that means
|
|
94
121
|
// "no external control".
|
|
95
|
-
await this.releaseToAuto().catch(err => {
|
|
122
|
+
await this.serialized(() => this.releaseToAuto()).catch(err => {
|
|
96
123
|
console.error(`SunspecBatteryScheduleHandler ${this.applianceIdForLog}: auto release failed: ${err}`);
|
|
97
124
|
});
|
|
98
125
|
}
|
|
99
126
|
}
|
|
100
127
|
dispose() {
|
|
101
128
|
this.isDisposed = true;
|
|
129
|
+
this.stopKeepalive();
|
|
102
130
|
super.dispose();
|
|
103
131
|
}
|
|
104
132
|
async onInit(_active) {
|
|
@@ -134,11 +162,24 @@ class SunspecBatteryScheduleHandler extends storage_schedule_handler_js_1.Storag
|
|
|
134
162
|
return { ...baseline };
|
|
135
163
|
}
|
|
136
164
|
onChange(active, _previous) {
|
|
137
|
-
|
|
165
|
+
if (active.entry.direction === enyo_data_bus_value_js_1.EnyoStorageScheduleDirectionEnum.Idle) {
|
|
166
|
+
this.stopKeepalive();
|
|
167
|
+
}
|
|
168
|
+
else {
|
|
169
|
+
this.limitEntry = active;
|
|
170
|
+
this.lastLimitWriteAtMs = this.clock();
|
|
171
|
+
this.startKeepalive();
|
|
172
|
+
}
|
|
173
|
+
void this.serialized(() => this.applyEntry(active)).catch(err => {
|
|
138
174
|
console.error(`SunspecBatteryScheduleHandler ${this.applianceIdForLog}: onChange write failed for entry ${active.indexInSchedule}: ${err}`);
|
|
139
175
|
});
|
|
140
176
|
}
|
|
141
177
|
onRollback(_registers) {
|
|
178
|
+
// Stop refreshing in both branches. On a replacement the new schedule's
|
|
179
|
+
// first onChange restarts it; if that install fails instead, the old
|
|
180
|
+
// limit must be left to expire rather than kept alive with no schedule
|
|
181
|
+
// running.
|
|
182
|
+
this.stopKeepalive();
|
|
142
183
|
if (this.suppressNextRollbackWrite) {
|
|
143
184
|
// Schedule-to-schedule replacement. Do NOT write the snapshot
|
|
144
185
|
// back; the new schedule's first `onChange` will own the
|
|
@@ -159,7 +200,7 @@ class SunspecBatteryScheduleHandler extends storage_schedule_handler_js_1.Storag
|
|
|
159
200
|
const chargeSource = this.originalBaseline?.chaGriSet;
|
|
160
201
|
this.originalBaseline = undefined;
|
|
161
202
|
this.installedWChaMax = undefined;
|
|
162
|
-
void this.releaseToAuto(chargeSource).catch(err => {
|
|
203
|
+
void this.serialized(() => this.releaseToAuto(chargeSource)).catch(err => {
|
|
163
204
|
console.error(`SunspecBatteryScheduleHandler ${this.applianceIdForLog}: onRollback failed: ${err}`);
|
|
164
205
|
});
|
|
165
206
|
}
|
|
@@ -192,6 +233,49 @@ class SunspecBatteryScheduleHandler extends storage_schedule_handler_js_1.Storag
|
|
|
192
233
|
'storCtlMod', 'chaGriSet', 'inWRte', 'outWRte',
|
|
193
234
|
]);
|
|
194
235
|
}
|
|
236
|
+
serialized(write) {
|
|
237
|
+
const run = this.writeChain.then(write);
|
|
238
|
+
// The chain itself never rejects, so one failed write does not block the next.
|
|
239
|
+
this.writeChain = run.catch(() => undefined);
|
|
240
|
+
return run;
|
|
241
|
+
}
|
|
242
|
+
startKeepalive() {
|
|
243
|
+
if (this.keepaliveIntervalId === undefined) {
|
|
244
|
+
this.keepaliveIntervalId = this.interval.createInterval(KEEPALIVE_CHECK_INTERVAL, () => this.onKeepalive());
|
|
245
|
+
}
|
|
246
|
+
}
|
|
247
|
+
stopKeepalive() {
|
|
248
|
+
this.limitEntry = undefined;
|
|
249
|
+
if (this.keepaliveIntervalId !== undefined) {
|
|
250
|
+
this.interval.stopInterval(this.keepaliveIntervalId);
|
|
251
|
+
this.keepaliveIntervalId = undefined;
|
|
252
|
+
}
|
|
253
|
+
}
|
|
254
|
+
/**
|
|
255
|
+
* Rewrite the active limit every third of the revert timeout, so it outlives
|
|
256
|
+
* the device's InOutWRte_RvrtTms for as long as this handler is alive — and
|
|
257
|
+
* lapses on its own once it is not.
|
|
258
|
+
*/
|
|
259
|
+
onKeepalive() {
|
|
260
|
+
const entry = this.limitEntry;
|
|
261
|
+
if (!entry || this.isDisposed || this.getActiveEntry() === undefined) {
|
|
262
|
+
this.stopKeepalive();
|
|
263
|
+
return;
|
|
264
|
+
}
|
|
265
|
+
const refreshMs = this.sunspecClient.getBatteryRateRevertTimeoutSeconds() * 1000 / 3;
|
|
266
|
+
if (this.clock() - this.lastLimitWriteAtMs < refreshMs) {
|
|
267
|
+
return;
|
|
268
|
+
}
|
|
269
|
+
this.lastLimitWriteAtMs = this.clock();
|
|
270
|
+
void this.serialized(async () => {
|
|
271
|
+
// An entry transition may have queued ahead of us; refresh only what is still active.
|
|
272
|
+
if (this.limitEntry !== entry)
|
|
273
|
+
return;
|
|
274
|
+
await this.applyEntry(entry);
|
|
275
|
+
}).catch(err => {
|
|
276
|
+
console.error(`SunspecBatteryScheduleHandler ${this.applianceIdForLog}: keepalive refresh failed for entry ${entry.indexInSchedule}: ${err}`);
|
|
277
|
+
});
|
|
278
|
+
}
|
|
195
279
|
onError(err) {
|
|
196
280
|
this.onErrorCallback?.(err);
|
|
197
281
|
}
|
|
@@ -11,6 +11,8 @@ import { type SunspecBatteryControls } from "./sunspec-interfaces.cjs";
|
|
|
11
11
|
export interface BatteryControlsClient {
|
|
12
12
|
readBatteryControls(unitId: number): Promise<SunspecBatteryControls | null>;
|
|
13
13
|
writeBatteryControls(unitId: number, controls: Partial<SunspecBatteryControls>): Promise<boolean>;
|
|
14
|
+
/** Model 124 InOutWRte_RvrtTms the battery is configured with on connect; drives the keepalive. */
|
|
15
|
+
getBatteryRateRevertTimeoutSeconds(): number;
|
|
14
16
|
}
|
|
15
17
|
/**
|
|
16
18
|
* Narrow interface for the only `SnapshotService` method the schedule handler
|
|
@@ -83,6 +85,25 @@ export declare class SunspecBatteryScheduleHandler extends StorageScheduleHandle
|
|
|
83
85
|
* path can tell "released and gone" from "released and still live".
|
|
84
86
|
*/
|
|
85
87
|
private isDisposed;
|
|
88
|
+
private readonly clock;
|
|
89
|
+
/**
|
|
90
|
+
* The Charge / Discharge entry currently enforced on the device, kept alive
|
|
91
|
+
* by {@link onKeepalive}. The battery is given an InOutWRte_RvrtTms on
|
|
92
|
+
* connect, so the device drops a limit nobody refreshes — which is the point
|
|
93
|
+
* when the hub is gone, but would also end a long entry early if the hub is
|
|
94
|
+
* alive and simply has nothing new to send. Undefined while idle / released.
|
|
95
|
+
*/
|
|
96
|
+
private limitEntry?;
|
|
97
|
+
private lastLimitWriteAtMs;
|
|
98
|
+
private keepaliveIntervalId?;
|
|
99
|
+
private readonly interval;
|
|
100
|
+
/**
|
|
101
|
+
* Every Model 124 write goes through this chain. Each write is several
|
|
102
|
+
* register transactions; a keepalive refresh interleaved with an entry
|
|
103
|
+
* transition could otherwise leave the old entry's rate under the new
|
|
104
|
+
* entry's mode.
|
|
105
|
+
*/
|
|
106
|
+
private writeChain;
|
|
86
107
|
constructor(opts: SunspecBatteryScheduleHandlerOptions);
|
|
87
108
|
/**
|
|
88
109
|
* Override the base-class data-bus router so a schedule-to-schedule
|
|
@@ -116,6 +137,15 @@ export declare class SunspecBatteryScheduleHandler extends StorageScheduleHandle
|
|
|
116
137
|
* since grid charging is only ever switched on by a Charge entry.
|
|
117
138
|
*/
|
|
118
139
|
private releaseToAuto;
|
|
140
|
+
private serialized;
|
|
141
|
+
private startKeepalive;
|
|
142
|
+
private stopKeepalive;
|
|
143
|
+
/**
|
|
144
|
+
* Rewrite the active limit every third of the revert timeout, so it outlives
|
|
145
|
+
* the device's InOutWRte_RvrtTms for as long as this handler is alive — and
|
|
146
|
+
* lapses on its own once it is not.
|
|
147
|
+
*/
|
|
148
|
+
private onKeepalive;
|
|
119
149
|
protected onError(err: Error): void;
|
|
120
150
|
private applyEntry;
|
|
121
151
|
}
|
|
@@ -1687,6 +1687,10 @@ class SunspecBattery extends BaseSunspecDevice {
|
|
|
1687
1687
|
if (!this.hasRequiredModels()) {
|
|
1688
1688
|
throw new Error('No battery model found in device');
|
|
1689
1689
|
}
|
|
1690
|
+
// Give every limit a revert timeout so a hub that goes offline cannot leave the
|
|
1691
|
+
// battery blocked (devices ship with 0 = never revert). Written once here; the
|
|
1692
|
+
// schedule handler refreshes active limits inside this window.
|
|
1693
|
+
await this.sunspecClient.writeBatteryRateRevertTimeout(this.unitId);
|
|
1690
1694
|
// Get device info
|
|
1691
1695
|
const commonData = await this.sunspecClient.readCommonBlock(this.unitId);
|
|
1692
1696
|
const batteryData = await this.sunspecClient.readBatteryData(this.unitId);
|
|
@@ -1758,6 +1762,15 @@ class SunspecBattery extends BaseSunspecDevice {
|
|
|
1758
1762
|
}
|
|
1759
1763
|
this.startDataBusListening();
|
|
1760
1764
|
}
|
|
1765
|
+
/**
|
|
1766
|
+
* Re-apply the rate revert timeout once per recovered connection. An outage long
|
|
1767
|
+
* enough to need a reconnect may be the inverter rebooting, and nothing guarantees
|
|
1768
|
+
* the register survives that. Runs after reconnect revalidation, so Model 124 has
|
|
1769
|
+
* been rediscovered and the new socket is in place.
|
|
1770
|
+
*/
|
|
1771
|
+
async onConnectionRestored() {
|
|
1772
|
+
await this.sunspecClient.writeBatteryRateRevertTimeout(this.unitId);
|
|
1773
|
+
}
|
|
1761
1774
|
async disconnect() {
|
|
1762
1775
|
this.stopDataBusListening();
|
|
1763
1776
|
if (this.calibrationDriver) {
|
|
@@ -617,6 +617,13 @@ export declare class SunspecBattery extends BaseSunspecDevice {
|
|
|
617
617
|
* Connect to the battery and create/update the appliance
|
|
618
618
|
*/
|
|
619
619
|
connect(inverterApplianceId?: string): Promise<void>;
|
|
620
|
+
/**
|
|
621
|
+
* Re-apply the rate revert timeout once per recovered connection. An outage long
|
|
622
|
+
* enough to need a reconnect may be the inverter rebooting, and nothing guarantees
|
|
623
|
+
* the register survives that. Runs after reconnect revalidation, so Model 124 has
|
|
624
|
+
* been rediscovered and the new socket is in place.
|
|
625
|
+
*/
|
|
626
|
+
protected onConnectionRestored(): Promise<void>;
|
|
620
627
|
disconnect(): Promise<void>;
|
|
621
628
|
/**
|
|
622
629
|
* Map SunSpec battery charge state to Enyo battery state
|
|
@@ -3,7 +3,7 @@
|
|
|
3
3
|
* SunSpec block interfaces with block numbers
|
|
4
4
|
*/
|
|
5
5
|
Object.defineProperty(exports, "__esModule", { value: true });
|
|
6
|
-
exports.SUNSPEC_CONTROLLABLE_FEATURES = exports.SunspecMeterCapability = exports.SunspecBatteryFeatureModeKind = exports.SunspecBatteryCapability = exports.SunspecPvPowerOrigin = exports.SunspecPvPowerSource = exports.SunspecInverterCapability = exports.SunspecStorageMode = exports.SunspecChargeSource = exports.SunspecVArPctMode = exports.SunspecEnableControl = exports.SunspecConnectionControl = exports.SunspecStorageControlMode = exports.SunspecBatteryEvent1 = exports.SunspecBatteryBankState = exports.SunspecBatteryType = exports.SunspecBatteryControlMode = exports.SunspecBatteryChargeState = exports.SunspecInverterOperatingState = exports.SunspecMPPTOperatingState = exports.SUNSPEC_CONNECTION_LOST_CODE = exports.SunspecInverterEvent1 = exports.SunspecModelId = exports.DEFAULT_MODBUS_RESILIENCE_CONFIG = exports.DEFAULT_RETRY_CONFIG = void 0;
|
|
6
|
+
exports.SUNSPEC_CONTROLLABLE_FEATURES = exports.SunspecMeterCapability = exports.SunspecBatteryFeatureModeKind = exports.SunspecBatteryCapability = exports.SunspecPvPowerOrigin = exports.SunspecPvPowerSource = exports.SunspecInverterCapability = exports.SunspecStorageMode = exports.SunspecChargeSource = exports.SunspecVArPctMode = exports.SunspecEnableControl = exports.SunspecConnectionControl = exports.MAX_BATTERY_RATE_REVERT_TIMEOUT_SECONDS = exports.MIN_BATTERY_RATE_REVERT_TIMEOUT_SECONDS = exports.DEFAULT_BATTERY_RATE_REVERT_TIMEOUT_SECONDS = exports.SunspecStorageControlMode = exports.SunspecBatteryEvent1 = exports.SunspecBatteryBankState = exports.SunspecBatteryType = exports.SunspecBatteryControlMode = exports.SunspecBatteryChargeState = exports.SunspecInverterOperatingState = exports.SunspecMPPTOperatingState = exports.SUNSPEC_CONNECTION_LOST_CODE = exports.SunspecInverterEvent1 = exports.SunspecModelId = exports.DEFAULT_MODBUS_RESILIENCE_CONFIG = exports.DEFAULT_RETRY_CONFIG = void 0;
|
|
7
7
|
const enyo_battery_appliance_js_1 = require("@enyo-energy/energy-app-sdk/dist/types/enyo-battery-appliance.js");
|
|
8
8
|
exports.DEFAULT_RETRY_CONFIG = {
|
|
9
9
|
phases: [
|
|
@@ -228,6 +228,28 @@ var SunspecStorageControlMode;
|
|
|
228
228
|
// Note: Higher bits may control other modes like autonomous/self-consumption
|
|
229
229
|
// but these are device-specific and not standardized in SunSpec
|
|
230
230
|
})(SunspecStorageControlMode || (exports.SunspecStorageControlMode = SunspecStorageControlMode = {}));
|
|
231
|
+
/**
|
|
232
|
+
* Default for Model 124 `InOutWRte_RvrtTms` (offset 15), written once when the
|
|
233
|
+
* battery connects. After this many seconds without a fresh rate write the device
|
|
234
|
+
* drops the InWRte / OutWRte setpoint and goes back to managing itself, so a hub
|
|
235
|
+
* that dies mid-schedule cannot leave the battery blocked. 0 on the device means
|
|
236
|
+
* "never revert", which is exactly the stuck state this guards against.
|
|
237
|
+
*
|
|
238
|
+
* Long enough to cover several refreshes by the schedule handler (it rewrites the
|
|
239
|
+
* active limit every third of the timeout), short enough that a dead hub is
|
|
240
|
+
* noticed within a couple of minutes.
|
|
241
|
+
*/
|
|
242
|
+
exports.DEFAULT_BATTERY_RATE_REVERT_TIMEOUT_SECONDS = 90;
|
|
243
|
+
/**
|
|
244
|
+
* Lower bound for the configurable revert timeout. Below this a single slow
|
|
245
|
+
* Modbus round-trip or a missed refresh lets the limit lapse mid-entry.
|
|
246
|
+
*/
|
|
247
|
+
exports.MIN_BATTERY_RATE_REVERT_TIMEOUT_SECONDS = 15;
|
|
248
|
+
/**
|
|
249
|
+
* Upper bound: InOutWRte_RvrtTms is a uint16 and 0xFFFF is the SunSpec
|
|
250
|
+
* "not implemented" marker.
|
|
251
|
+
*/
|
|
252
|
+
exports.MAX_BATTERY_RATE_REVERT_TIMEOUT_SECONDS = 0xFFFE;
|
|
231
253
|
/**
|
|
232
254
|
* Enum values for connection control
|
|
233
255
|
*/
|
|
@@ -533,6 +533,28 @@ export declare enum SunspecStorageControlMode {
|
|
|
533
533
|
CHARGE = 1,// Bit 0 - the InWRte charge-rate setpoint is active
|
|
534
534
|
DISCHARGE = 2
|
|
535
535
|
}
|
|
536
|
+
/**
|
|
537
|
+
* Default for Model 124 `InOutWRte_RvrtTms` (offset 15), written once when the
|
|
538
|
+
* battery connects. After this many seconds without a fresh rate write the device
|
|
539
|
+
* drops the InWRte / OutWRte setpoint and goes back to managing itself, so a hub
|
|
540
|
+
* that dies mid-schedule cannot leave the battery blocked. 0 on the device means
|
|
541
|
+
* "never revert", which is exactly the stuck state this guards against.
|
|
542
|
+
*
|
|
543
|
+
* Long enough to cover several refreshes by the schedule handler (it rewrites the
|
|
544
|
+
* active limit every third of the timeout), short enough that a dead hub is
|
|
545
|
+
* noticed within a couple of minutes.
|
|
546
|
+
*/
|
|
547
|
+
export declare const DEFAULT_BATTERY_RATE_REVERT_TIMEOUT_SECONDS = 90;
|
|
548
|
+
/**
|
|
549
|
+
* Lower bound for the configurable revert timeout. Below this a single slow
|
|
550
|
+
* Modbus round-trip or a missed refresh lets the limit lapse mid-entry.
|
|
551
|
+
*/
|
|
552
|
+
export declare const MIN_BATTERY_RATE_REVERT_TIMEOUT_SECONDS = 15;
|
|
553
|
+
/**
|
|
554
|
+
* Upper bound: InOutWRte_RvrtTms is a uint16 and 0xFFFF is the SunSpec
|
|
555
|
+
* "not implemented" marker.
|
|
556
|
+
*/
|
|
557
|
+
export declare const MAX_BATTERY_RATE_REVERT_TIMEOUT_SECONDS = 65534;
|
|
536
558
|
/**
|
|
537
559
|
* Battery data structure based on Model 124 (Basic Storage Controls)
|
|
538
560
|
*
|
|
@@ -254,6 +254,12 @@ class SunspecModbusClient {
|
|
|
254
254
|
// announces itself twice — once by the transport, once by this client's own close/reopen —
|
|
255
255
|
// and an app must not be told to re-authenticate twice for one loss.
|
|
256
256
|
unitSessionReportedLost = new Set();
|
|
257
|
+
// Model 124 InOutWRte_RvrtTms written once when a battery connects. See
|
|
258
|
+
// setBatteryRateRevertTimeoutSeconds().
|
|
259
|
+
batteryRateRevertTimeoutSeconds = sunspec_interfaces_js_1.DEFAULT_BATTERY_RATE_REVERT_TIMEOUT_SECONDS;
|
|
260
|
+
// Units whose InOutWRte_RvrtTms write has already failed and been warned about. Later
|
|
261
|
+
// failures on the same unit stay silent so a device without the register warns once.
|
|
262
|
+
batteryRateRevertWarnedUnits = new Set();
|
|
257
263
|
constructor(
|
|
258
264
|
// The host application. Only used to obtain the default Modbus backend via
|
|
259
265
|
// `energyApp.useModbus()`. May be omitted (`undefined`) when a `modbusFactory` is supplied.
|
|
@@ -2516,6 +2522,32 @@ class SunspecModbusClient {
|
|
|
2516
2522
|
return null;
|
|
2517
2523
|
}
|
|
2518
2524
|
}
|
|
2525
|
+
/**
|
|
2526
|
+
* Set the Model 124 `InOutWRte_RvrtTms` (seconds) written once when the battery
|
|
2527
|
+
* connects and once after every reconnect — e.g. 30 or 60. When no fresh rate write arrives within this window
|
|
2528
|
+
* the device drops the limit and manages itself again, so a hub that goes
|
|
2529
|
+
* offline cannot leave the battery blocked. The schedule handler refreshes an
|
|
2530
|
+
* active limit every third of this value.
|
|
2531
|
+
*
|
|
2532
|
+
* Call before `SunspecBattery.connect()`; a later change only reaches the
|
|
2533
|
+
* device on the next {@link writeBatteryRateRevertTimeout}. Must be an integer between
|
|
2534
|
+
* {@link MIN_BATTERY_RATE_REVERT_TIMEOUT_SECONDS} and
|
|
2535
|
+
* {@link MAX_BATTERY_RATE_REVERT_TIMEOUT_SECONDS}; 0 ("never revert") is
|
|
2536
|
+
* deliberately not accepted.
|
|
2537
|
+
*/
|
|
2538
|
+
setBatteryRateRevertTimeoutSeconds(seconds) {
|
|
2539
|
+
if (!Number.isInteger(seconds)
|
|
2540
|
+
|| seconds < sunspec_interfaces_js_1.MIN_BATTERY_RATE_REVERT_TIMEOUT_SECONDS
|
|
2541
|
+
|| seconds > sunspec_interfaces_js_1.MAX_BATTERY_RATE_REVERT_TIMEOUT_SECONDS) {
|
|
2542
|
+
throw new Error(`setBatteryRateRevertTimeoutSeconds: ${seconds} must be an integer between ` +
|
|
2543
|
+
`${sunspec_interfaces_js_1.MIN_BATTERY_RATE_REVERT_TIMEOUT_SECONDS} and ${sunspec_interfaces_js_1.MAX_BATTERY_RATE_REVERT_TIMEOUT_SECONDS}`);
|
|
2544
|
+
}
|
|
2545
|
+
this.batteryRateRevertTimeoutSeconds = seconds;
|
|
2546
|
+
}
|
|
2547
|
+
/** Current Model 124 `InOutWRte_RvrtTms` in seconds. */
|
|
2548
|
+
getBatteryRateRevertTimeoutSeconds() {
|
|
2549
|
+
return this.batteryRateRevertTimeoutSeconds;
|
|
2550
|
+
}
|
|
2519
2551
|
/**
|
|
2520
2552
|
* Write battery control settings to Model 124
|
|
2521
2553
|
*/
|
|
@@ -2598,6 +2630,40 @@ class SunspecModbusClient {
|
|
|
2598
2630
|
return false;
|
|
2599
2631
|
}
|
|
2600
2632
|
}
|
|
2633
|
+
/**
|
|
2634
|
+
* Write the configured InOutWRte_RvrtTms (Model 124 offset 15) to the device.
|
|
2635
|
+
* Called once by `SunspecBattery.connect()` and once per recovered connection;
|
|
2636
|
+
* the device keeps the value, so limit writes do not repeat it.
|
|
2637
|
+
*
|
|
2638
|
+
* Never throws: a device that rejects the register still takes limits, it just
|
|
2639
|
+
* won't revert them on its own (the pre-existing behaviour). The first failure
|
|
2640
|
+
* per unit is warned about, later ones are silent.
|
|
2641
|
+
*
|
|
2642
|
+
* @returns true when the value was written; false when the unit has no Model 124
|
|
2643
|
+
* or the write failed.
|
|
2644
|
+
*/
|
|
2645
|
+
async writeBatteryRateRevertTimeout(unitId) {
|
|
2646
|
+
const model = this.findModel(unitId, sunspec_interfaces_js_1.SunspecModelId.Battery);
|
|
2647
|
+
if (!model) {
|
|
2648
|
+
// 802-only batteries have no Model 124 and therefore nothing to revert.
|
|
2649
|
+
console.debug(`Battery model 124 not found on unit ${unitId}, skipping InOutWRte_RvrtTms`);
|
|
2650
|
+
return false;
|
|
2651
|
+
}
|
|
2652
|
+
const seconds = this.batteryRateRevertTimeoutSeconds;
|
|
2653
|
+
try {
|
|
2654
|
+
await this.writeRegisterValue(unitId, model.address + 15, seconds, 'uint16');
|
|
2655
|
+
console.log(`Unit ${unitId}: set battery rate revert timeout (InOutWRte_RvrtTms) to ${seconds}s`);
|
|
2656
|
+
return true;
|
|
2657
|
+
}
|
|
2658
|
+
catch (error) {
|
|
2659
|
+
if (!this.batteryRateRevertWarnedUnits.has(unitId)) {
|
|
2660
|
+
this.batteryRateRevertWarnedUnits.add(unitId);
|
|
2661
|
+
console.warn(`Unit ${unitId}: writing InOutWRte_RvrtTms=${seconds}s failed, battery limits will not ` +
|
|
2662
|
+
`auto-revert on this device: ${error instanceof Error ? error.message : String(error)}`);
|
|
2663
|
+
}
|
|
2664
|
+
return false;
|
|
2665
|
+
}
|
|
2666
|
+
}
|
|
2601
2667
|
/**
|
|
2602
2668
|
* Set battery storage mode (simplified interface)
|
|
2603
2669
|
*/
|
|
@@ -139,6 +139,8 @@ export declare class SunspecModbusClient {
|
|
|
139
139
|
private unitReconnectUnsubscribers;
|
|
140
140
|
private unitsWithSession;
|
|
141
141
|
private unitSessionReportedLost;
|
|
142
|
+
private batteryRateRevertTimeoutSeconds;
|
|
143
|
+
private batteryRateRevertWarnedUnits;
|
|
142
144
|
constructor(energyApp: EnergyApp | undefined, transport?: IModbusTransportConfig, resilience?: IModbusResilienceConfig, modbusFactory?: EnergyAppModbus | undefined);
|
|
143
145
|
/**
|
|
144
146
|
* The Modbus backend used to open per-unit connections: the caller-supplied {@link modbusFactory}
|
|
@@ -674,10 +676,39 @@ export declare class SunspecModbusClient {
|
|
|
674
676
|
* Read battery data from Model 124 (Basic Storage) with fallback to Model 802 / Model 803
|
|
675
677
|
*/
|
|
676
678
|
readBatteryData(unitId: number): Promise<SunspecBatteryData | null>;
|
|
679
|
+
/**
|
|
680
|
+
* Set the Model 124 `InOutWRte_RvrtTms` (seconds) written once when the battery
|
|
681
|
+
* connects and once after every reconnect — e.g. 30 or 60. When no fresh rate write arrives within this window
|
|
682
|
+
* the device drops the limit and manages itself again, so a hub that goes
|
|
683
|
+
* offline cannot leave the battery blocked. The schedule handler refreshes an
|
|
684
|
+
* active limit every third of this value.
|
|
685
|
+
*
|
|
686
|
+
* Call before `SunspecBattery.connect()`; a later change only reaches the
|
|
687
|
+
* device on the next {@link writeBatteryRateRevertTimeout}. Must be an integer between
|
|
688
|
+
* {@link MIN_BATTERY_RATE_REVERT_TIMEOUT_SECONDS} and
|
|
689
|
+
* {@link MAX_BATTERY_RATE_REVERT_TIMEOUT_SECONDS}; 0 ("never revert") is
|
|
690
|
+
* deliberately not accepted.
|
|
691
|
+
*/
|
|
692
|
+
setBatteryRateRevertTimeoutSeconds(seconds: number): void;
|
|
693
|
+
/** Current Model 124 `InOutWRte_RvrtTms` in seconds. */
|
|
694
|
+
getBatteryRateRevertTimeoutSeconds(): number;
|
|
677
695
|
/**
|
|
678
696
|
* Write battery control settings to Model 124
|
|
679
697
|
*/
|
|
680
698
|
writeBatteryControls(unitId: number, controls: Partial<SunspecBatteryControls>): Promise<boolean>;
|
|
699
|
+
/**
|
|
700
|
+
* Write the configured InOutWRte_RvrtTms (Model 124 offset 15) to the device.
|
|
701
|
+
* Called once by `SunspecBattery.connect()` and once per recovered connection;
|
|
702
|
+
* the device keeps the value, so limit writes do not repeat it.
|
|
703
|
+
*
|
|
704
|
+
* Never throws: a device that rejects the register still takes limits, it just
|
|
705
|
+
* won't revert them on its own (the pre-existing behaviour). The first failure
|
|
706
|
+
* per unit is warned about, later ones are silent.
|
|
707
|
+
*
|
|
708
|
+
* @returns true when the value was written; false when the unit has no Model 124
|
|
709
|
+
* or the write failed.
|
|
710
|
+
*/
|
|
711
|
+
writeBatteryRateRevertTimeout(unitId: number): Promise<boolean>;
|
|
681
712
|
/**
|
|
682
713
|
* Set battery storage mode (simplified interface)
|
|
683
714
|
*/
|
package/dist/cjs/version.cjs
CHANGED
package/dist/cjs/version.d.cts
CHANGED
|
@@ -11,6 +11,8 @@ import { type SunspecBatteryControls } from "./sunspec-interfaces.js";
|
|
|
11
11
|
export interface BatteryControlsClient {
|
|
12
12
|
readBatteryControls(unitId: number): Promise<SunspecBatteryControls | null>;
|
|
13
13
|
writeBatteryControls(unitId: number, controls: Partial<SunspecBatteryControls>): Promise<boolean>;
|
|
14
|
+
/** Model 124 InOutWRte_RvrtTms the battery is configured with on connect; drives the keepalive. */
|
|
15
|
+
getBatteryRateRevertTimeoutSeconds(): number;
|
|
14
16
|
}
|
|
15
17
|
/**
|
|
16
18
|
* Narrow interface for the only `SnapshotService` method the schedule handler
|
|
@@ -83,6 +85,25 @@ export declare class SunspecBatteryScheduleHandler extends StorageScheduleHandle
|
|
|
83
85
|
* path can tell "released and gone" from "released and still live".
|
|
84
86
|
*/
|
|
85
87
|
private isDisposed;
|
|
88
|
+
private readonly clock;
|
|
89
|
+
/**
|
|
90
|
+
* The Charge / Discharge entry currently enforced on the device, kept alive
|
|
91
|
+
* by {@link onKeepalive}. The battery is given an InOutWRte_RvrtTms on
|
|
92
|
+
* connect, so the device drops a limit nobody refreshes — which is the point
|
|
93
|
+
* when the hub is gone, but would also end a long entry early if the hub is
|
|
94
|
+
* alive and simply has nothing new to send. Undefined while idle / released.
|
|
95
|
+
*/
|
|
96
|
+
private limitEntry?;
|
|
97
|
+
private lastLimitWriteAtMs;
|
|
98
|
+
private keepaliveIntervalId?;
|
|
99
|
+
private readonly interval;
|
|
100
|
+
/**
|
|
101
|
+
* Every Model 124 write goes through this chain. Each write is several
|
|
102
|
+
* register transactions; a keepalive refresh interleaved with an entry
|
|
103
|
+
* transition could otherwise leave the old entry's rate under the new
|
|
104
|
+
* entry's mode.
|
|
105
|
+
*/
|
|
106
|
+
private writeChain;
|
|
86
107
|
constructor(opts: SunspecBatteryScheduleHandlerOptions);
|
|
87
108
|
/**
|
|
88
109
|
* Override the base-class data-bus router so a schedule-to-schedule
|
|
@@ -116,6 +137,15 @@ export declare class SunspecBatteryScheduleHandler extends StorageScheduleHandle
|
|
|
116
137
|
* since grid charging is only ever switched on by a Charge entry.
|
|
117
138
|
*/
|
|
118
139
|
private releaseToAuto;
|
|
140
|
+
private serialized;
|
|
141
|
+
private startKeepalive;
|
|
142
|
+
private stopKeepalive;
|
|
143
|
+
/**
|
|
144
|
+
* Rewrite the active limit every third of the revert timeout, so it outlives
|
|
145
|
+
* the device's InOutWRte_RvrtTms for as long as this handler is alive — and
|
|
146
|
+
* lapses on its own once it is not.
|
|
147
|
+
*/
|
|
148
|
+
private onKeepalive;
|
|
119
149
|
protected onError(err: Error): void;
|
|
120
150
|
private applyEntry;
|
|
121
151
|
}
|
|
@@ -1,6 +1,12 @@
|
|
|
1
1
|
import { StorageScheduleHandler, } from "@enyo-energy/energy-app-sdk/dist/implementations/storage/storage-schedule-handler.js";
|
|
2
2
|
import { EnyoStorageScheduleDirectionEnum, EnyoStorageScheduleModeEnum, } from "@enyo-energy/energy-app-sdk/dist/types/enyo-data-bus-value.js";
|
|
3
3
|
import { SunspecChargeSource, SunspecStorageControlMode, } from "./sunspec-interfaces.js";
|
|
4
|
+
/**
|
|
5
|
+
* How often the keepalive checks whether the active limit is due a refresh.
|
|
6
|
+
* The refresh itself happens every third of the revert timeout; this only
|
|
7
|
+
* bounds how late it can be.
|
|
8
|
+
*/
|
|
9
|
+
const KEEPALIVE_CHECK_INTERVAL = '5s';
|
|
4
10
|
/**
|
|
5
11
|
* Concrete `StorageScheduleHandler` for SunSpec Model 124 batteries. The base
|
|
6
12
|
* class owns the data-bus subscription, the 1-second tick, schedule
|
|
@@ -38,6 +44,25 @@ export class SunspecBatteryScheduleHandler extends StorageScheduleHandler {
|
|
|
38
44
|
* path can tell "released and gone" from "released and still live".
|
|
39
45
|
*/
|
|
40
46
|
isDisposed = false;
|
|
47
|
+
clock;
|
|
48
|
+
/**
|
|
49
|
+
* The Charge / Discharge entry currently enforced on the device, kept alive
|
|
50
|
+
* by {@link onKeepalive}. The battery is given an InOutWRte_RvrtTms on
|
|
51
|
+
* connect, so the device drops a limit nobody refreshes — which is the point
|
|
52
|
+
* when the hub is gone, but would also end a long entry early if the hub is
|
|
53
|
+
* alive and simply has nothing new to send. Undefined while idle / released.
|
|
54
|
+
*/
|
|
55
|
+
limitEntry;
|
|
56
|
+
lastLimitWriteAtMs = 0;
|
|
57
|
+
keepaliveIntervalId;
|
|
58
|
+
interval;
|
|
59
|
+
/**
|
|
60
|
+
* Every Model 124 write goes through this chain. Each write is several
|
|
61
|
+
* register transactions; a keepalive refresh interleaved with an entry
|
|
62
|
+
* transition could otherwise leave the old entry's rate under the new
|
|
63
|
+
* entry's mode.
|
|
64
|
+
*/
|
|
65
|
+
writeChain = Promise.resolve();
|
|
41
66
|
constructor(opts) {
|
|
42
67
|
super(opts);
|
|
43
68
|
this.sunspecClient = opts.sunspecClient;
|
|
@@ -45,6 +70,8 @@ export class SunspecBatteryScheduleHandler extends StorageScheduleHandler {
|
|
|
45
70
|
this.applianceIdForLog = opts.applianceId;
|
|
46
71
|
this.getSnapshotService = opts.getSnapshotService;
|
|
47
72
|
this.onErrorCallback = opts.onErrorCallback;
|
|
73
|
+
this.interval = opts.interval;
|
|
74
|
+
this.clock = opts.now ?? (() => Date.now());
|
|
48
75
|
}
|
|
49
76
|
/**
|
|
50
77
|
* Override the base-class data-bus router so a schedule-to-schedule
|
|
@@ -89,13 +116,14 @@ export class SunspecBatteryScheduleHandler extends StorageScheduleHandler {
|
|
|
89
116
|
// Writing the release unconditionally is safe because it is
|
|
90
117
|
// idempotent: it is exactly the register set that means
|
|
91
118
|
// "no external control".
|
|
92
|
-
await this.releaseToAuto().catch(err => {
|
|
119
|
+
await this.serialized(() => this.releaseToAuto()).catch(err => {
|
|
93
120
|
console.error(`SunspecBatteryScheduleHandler ${this.applianceIdForLog}: auto release failed: ${err}`);
|
|
94
121
|
});
|
|
95
122
|
}
|
|
96
123
|
}
|
|
97
124
|
dispose() {
|
|
98
125
|
this.isDisposed = true;
|
|
126
|
+
this.stopKeepalive();
|
|
99
127
|
super.dispose();
|
|
100
128
|
}
|
|
101
129
|
async onInit(_active) {
|
|
@@ -131,11 +159,24 @@ export class SunspecBatteryScheduleHandler extends StorageScheduleHandler {
|
|
|
131
159
|
return { ...baseline };
|
|
132
160
|
}
|
|
133
161
|
onChange(active, _previous) {
|
|
134
|
-
|
|
162
|
+
if (active.entry.direction === EnyoStorageScheduleDirectionEnum.Idle) {
|
|
163
|
+
this.stopKeepalive();
|
|
164
|
+
}
|
|
165
|
+
else {
|
|
166
|
+
this.limitEntry = active;
|
|
167
|
+
this.lastLimitWriteAtMs = this.clock();
|
|
168
|
+
this.startKeepalive();
|
|
169
|
+
}
|
|
170
|
+
void this.serialized(() => this.applyEntry(active)).catch(err => {
|
|
135
171
|
console.error(`SunspecBatteryScheduleHandler ${this.applianceIdForLog}: onChange write failed for entry ${active.indexInSchedule}: ${err}`);
|
|
136
172
|
});
|
|
137
173
|
}
|
|
138
174
|
onRollback(_registers) {
|
|
175
|
+
// Stop refreshing in both branches. On a replacement the new schedule's
|
|
176
|
+
// first onChange restarts it; if that install fails instead, the old
|
|
177
|
+
// limit must be left to expire rather than kept alive with no schedule
|
|
178
|
+
// running.
|
|
179
|
+
this.stopKeepalive();
|
|
139
180
|
if (this.suppressNextRollbackWrite) {
|
|
140
181
|
// Schedule-to-schedule replacement. Do NOT write the snapshot
|
|
141
182
|
// back; the new schedule's first `onChange` will own the
|
|
@@ -156,7 +197,7 @@ export class SunspecBatteryScheduleHandler extends StorageScheduleHandler {
|
|
|
156
197
|
const chargeSource = this.originalBaseline?.chaGriSet;
|
|
157
198
|
this.originalBaseline = undefined;
|
|
158
199
|
this.installedWChaMax = undefined;
|
|
159
|
-
void this.releaseToAuto(chargeSource).catch(err => {
|
|
200
|
+
void this.serialized(() => this.releaseToAuto(chargeSource)).catch(err => {
|
|
160
201
|
console.error(`SunspecBatteryScheduleHandler ${this.applianceIdForLog}: onRollback failed: ${err}`);
|
|
161
202
|
});
|
|
162
203
|
}
|
|
@@ -189,6 +230,49 @@ export class SunspecBatteryScheduleHandler extends StorageScheduleHandler {
|
|
|
189
230
|
'storCtlMod', 'chaGriSet', 'inWRte', 'outWRte',
|
|
190
231
|
]);
|
|
191
232
|
}
|
|
233
|
+
serialized(write) {
|
|
234
|
+
const run = this.writeChain.then(write);
|
|
235
|
+
// The chain itself never rejects, so one failed write does not block the next.
|
|
236
|
+
this.writeChain = run.catch(() => undefined);
|
|
237
|
+
return run;
|
|
238
|
+
}
|
|
239
|
+
startKeepalive() {
|
|
240
|
+
if (this.keepaliveIntervalId === undefined) {
|
|
241
|
+
this.keepaliveIntervalId = this.interval.createInterval(KEEPALIVE_CHECK_INTERVAL, () => this.onKeepalive());
|
|
242
|
+
}
|
|
243
|
+
}
|
|
244
|
+
stopKeepalive() {
|
|
245
|
+
this.limitEntry = undefined;
|
|
246
|
+
if (this.keepaliveIntervalId !== undefined) {
|
|
247
|
+
this.interval.stopInterval(this.keepaliveIntervalId);
|
|
248
|
+
this.keepaliveIntervalId = undefined;
|
|
249
|
+
}
|
|
250
|
+
}
|
|
251
|
+
/**
|
|
252
|
+
* Rewrite the active limit every third of the revert timeout, so it outlives
|
|
253
|
+
* the device's InOutWRte_RvrtTms for as long as this handler is alive — and
|
|
254
|
+
* lapses on its own once it is not.
|
|
255
|
+
*/
|
|
256
|
+
onKeepalive() {
|
|
257
|
+
const entry = this.limitEntry;
|
|
258
|
+
if (!entry || this.isDisposed || this.getActiveEntry() === undefined) {
|
|
259
|
+
this.stopKeepalive();
|
|
260
|
+
return;
|
|
261
|
+
}
|
|
262
|
+
const refreshMs = this.sunspecClient.getBatteryRateRevertTimeoutSeconds() * 1000 / 3;
|
|
263
|
+
if (this.clock() - this.lastLimitWriteAtMs < refreshMs) {
|
|
264
|
+
return;
|
|
265
|
+
}
|
|
266
|
+
this.lastLimitWriteAtMs = this.clock();
|
|
267
|
+
void this.serialized(async () => {
|
|
268
|
+
// An entry transition may have queued ahead of us; refresh only what is still active.
|
|
269
|
+
if (this.limitEntry !== entry)
|
|
270
|
+
return;
|
|
271
|
+
await this.applyEntry(entry);
|
|
272
|
+
}).catch(err => {
|
|
273
|
+
console.error(`SunspecBatteryScheduleHandler ${this.applianceIdForLog}: keepalive refresh failed for entry ${entry.indexInSchedule}: ${err}`);
|
|
274
|
+
});
|
|
275
|
+
}
|
|
192
276
|
onError(err) {
|
|
193
277
|
this.onErrorCallback?.(err);
|
|
194
278
|
}
|
|
@@ -617,6 +617,13 @@ export declare class SunspecBattery extends BaseSunspecDevice {
|
|
|
617
617
|
* Connect to the battery and create/update the appliance
|
|
618
618
|
*/
|
|
619
619
|
connect(inverterApplianceId?: string): Promise<void>;
|
|
620
|
+
/**
|
|
621
|
+
* Re-apply the rate revert timeout once per recovered connection. An outage long
|
|
622
|
+
* enough to need a reconnect may be the inverter rebooting, and nothing guarantees
|
|
623
|
+
* the register survives that. Runs after reconnect revalidation, so Model 124 has
|
|
624
|
+
* been rediscovered and the new socket is in place.
|
|
625
|
+
*/
|
|
626
|
+
protected onConnectionRestored(): Promise<void>;
|
|
620
627
|
disconnect(): Promise<void>;
|
|
621
628
|
/**
|
|
622
629
|
* Map SunSpec battery charge state to Enyo battery state
|
package/dist/sunspec-devices.js
CHANGED
|
@@ -1677,6 +1677,10 @@ export class SunspecBattery extends BaseSunspecDevice {
|
|
|
1677
1677
|
if (!this.hasRequiredModels()) {
|
|
1678
1678
|
throw new Error('No battery model found in device');
|
|
1679
1679
|
}
|
|
1680
|
+
// Give every limit a revert timeout so a hub that goes offline cannot leave the
|
|
1681
|
+
// battery blocked (devices ship with 0 = never revert). Written once here; the
|
|
1682
|
+
// schedule handler refreshes active limits inside this window.
|
|
1683
|
+
await this.sunspecClient.writeBatteryRateRevertTimeout(this.unitId);
|
|
1680
1684
|
// Get device info
|
|
1681
1685
|
const commonData = await this.sunspecClient.readCommonBlock(this.unitId);
|
|
1682
1686
|
const batteryData = await this.sunspecClient.readBatteryData(this.unitId);
|
|
@@ -1748,6 +1752,15 @@ export class SunspecBattery extends BaseSunspecDevice {
|
|
|
1748
1752
|
}
|
|
1749
1753
|
this.startDataBusListening();
|
|
1750
1754
|
}
|
|
1755
|
+
/**
|
|
1756
|
+
* Re-apply the rate revert timeout once per recovered connection. An outage long
|
|
1757
|
+
* enough to need a reconnect may be the inverter rebooting, and nothing guarantees
|
|
1758
|
+
* the register survives that. Runs after reconnect revalidation, so Model 124 has
|
|
1759
|
+
* been rediscovered and the new socket is in place.
|
|
1760
|
+
*/
|
|
1761
|
+
async onConnectionRestored() {
|
|
1762
|
+
await this.sunspecClient.writeBatteryRateRevertTimeout(this.unitId);
|
|
1763
|
+
}
|
|
1751
1764
|
async disconnect() {
|
|
1752
1765
|
this.stopDataBusListening();
|
|
1753
1766
|
if (this.calibrationDriver) {
|
|
@@ -533,6 +533,28 @@ export declare enum SunspecStorageControlMode {
|
|
|
533
533
|
CHARGE = 1,// Bit 0 - the InWRte charge-rate setpoint is active
|
|
534
534
|
DISCHARGE = 2
|
|
535
535
|
}
|
|
536
|
+
/**
|
|
537
|
+
* Default for Model 124 `InOutWRte_RvrtTms` (offset 15), written once when the
|
|
538
|
+
* battery connects. After this many seconds without a fresh rate write the device
|
|
539
|
+
* drops the InWRte / OutWRte setpoint and goes back to managing itself, so a hub
|
|
540
|
+
* that dies mid-schedule cannot leave the battery blocked. 0 on the device means
|
|
541
|
+
* "never revert", which is exactly the stuck state this guards against.
|
|
542
|
+
*
|
|
543
|
+
* Long enough to cover several refreshes by the schedule handler (it rewrites the
|
|
544
|
+
* active limit every third of the timeout), short enough that a dead hub is
|
|
545
|
+
* noticed within a couple of minutes.
|
|
546
|
+
*/
|
|
547
|
+
export declare const DEFAULT_BATTERY_RATE_REVERT_TIMEOUT_SECONDS = 90;
|
|
548
|
+
/**
|
|
549
|
+
* Lower bound for the configurable revert timeout. Below this a single slow
|
|
550
|
+
* Modbus round-trip or a missed refresh lets the limit lapse mid-entry.
|
|
551
|
+
*/
|
|
552
|
+
export declare const MIN_BATTERY_RATE_REVERT_TIMEOUT_SECONDS = 15;
|
|
553
|
+
/**
|
|
554
|
+
* Upper bound: InOutWRte_RvrtTms is a uint16 and 0xFFFF is the SunSpec
|
|
555
|
+
* "not implemented" marker.
|
|
556
|
+
*/
|
|
557
|
+
export declare const MAX_BATTERY_RATE_REVERT_TIMEOUT_SECONDS = 65534;
|
|
536
558
|
/**
|
|
537
559
|
* Battery data structure based on Model 124 (Basic Storage Controls)
|
|
538
560
|
*
|
|
@@ -225,6 +225,28 @@ export var SunspecStorageControlMode;
|
|
|
225
225
|
// Note: Higher bits may control other modes like autonomous/self-consumption
|
|
226
226
|
// but these are device-specific and not standardized in SunSpec
|
|
227
227
|
})(SunspecStorageControlMode || (SunspecStorageControlMode = {}));
|
|
228
|
+
/**
|
|
229
|
+
* Default for Model 124 `InOutWRte_RvrtTms` (offset 15), written once when the
|
|
230
|
+
* battery connects. After this many seconds without a fresh rate write the device
|
|
231
|
+
* drops the InWRte / OutWRte setpoint and goes back to managing itself, so a hub
|
|
232
|
+
* that dies mid-schedule cannot leave the battery blocked. 0 on the device means
|
|
233
|
+
* "never revert", which is exactly the stuck state this guards against.
|
|
234
|
+
*
|
|
235
|
+
* Long enough to cover several refreshes by the schedule handler (it rewrites the
|
|
236
|
+
* active limit every third of the timeout), short enough that a dead hub is
|
|
237
|
+
* noticed within a couple of minutes.
|
|
238
|
+
*/
|
|
239
|
+
export const DEFAULT_BATTERY_RATE_REVERT_TIMEOUT_SECONDS = 90;
|
|
240
|
+
/**
|
|
241
|
+
* Lower bound for the configurable revert timeout. Below this a single slow
|
|
242
|
+
* Modbus round-trip or a missed refresh lets the limit lapse mid-entry.
|
|
243
|
+
*/
|
|
244
|
+
export const MIN_BATTERY_RATE_REVERT_TIMEOUT_SECONDS = 15;
|
|
245
|
+
/**
|
|
246
|
+
* Upper bound: InOutWRte_RvrtTms is a uint16 and 0xFFFF is the SunSpec
|
|
247
|
+
* "not implemented" marker.
|
|
248
|
+
*/
|
|
249
|
+
export const MAX_BATTERY_RATE_REVERT_TIMEOUT_SECONDS = 0xFFFE;
|
|
228
250
|
/**
|
|
229
251
|
* Enum values for connection control
|
|
230
252
|
*/
|
|
@@ -139,6 +139,8 @@ export declare class SunspecModbusClient {
|
|
|
139
139
|
private unitReconnectUnsubscribers;
|
|
140
140
|
private unitsWithSession;
|
|
141
141
|
private unitSessionReportedLost;
|
|
142
|
+
private batteryRateRevertTimeoutSeconds;
|
|
143
|
+
private batteryRateRevertWarnedUnits;
|
|
142
144
|
constructor(energyApp: EnergyApp | undefined, transport?: IModbusTransportConfig, resilience?: IModbusResilienceConfig, modbusFactory?: EnergyAppModbus | undefined);
|
|
143
145
|
/**
|
|
144
146
|
* The Modbus backend used to open per-unit connections: the caller-supplied {@link modbusFactory}
|
|
@@ -674,10 +676,39 @@ export declare class SunspecModbusClient {
|
|
|
674
676
|
* Read battery data from Model 124 (Basic Storage) with fallback to Model 802 / Model 803
|
|
675
677
|
*/
|
|
676
678
|
readBatteryData(unitId: number): Promise<SunspecBatteryData | null>;
|
|
679
|
+
/**
|
|
680
|
+
* Set the Model 124 `InOutWRte_RvrtTms` (seconds) written once when the battery
|
|
681
|
+
* connects and once after every reconnect — e.g. 30 or 60. When no fresh rate write arrives within this window
|
|
682
|
+
* the device drops the limit and manages itself again, so a hub that goes
|
|
683
|
+
* offline cannot leave the battery blocked. The schedule handler refreshes an
|
|
684
|
+
* active limit every third of this value.
|
|
685
|
+
*
|
|
686
|
+
* Call before `SunspecBattery.connect()`; a later change only reaches the
|
|
687
|
+
* device on the next {@link writeBatteryRateRevertTimeout}. Must be an integer between
|
|
688
|
+
* {@link MIN_BATTERY_RATE_REVERT_TIMEOUT_SECONDS} and
|
|
689
|
+
* {@link MAX_BATTERY_RATE_REVERT_TIMEOUT_SECONDS}; 0 ("never revert") is
|
|
690
|
+
* deliberately not accepted.
|
|
691
|
+
*/
|
|
692
|
+
setBatteryRateRevertTimeoutSeconds(seconds: number): void;
|
|
693
|
+
/** Current Model 124 `InOutWRte_RvrtTms` in seconds. */
|
|
694
|
+
getBatteryRateRevertTimeoutSeconds(): number;
|
|
677
695
|
/**
|
|
678
696
|
* Write battery control settings to Model 124
|
|
679
697
|
*/
|
|
680
698
|
writeBatteryControls(unitId: number, controls: Partial<SunspecBatteryControls>): Promise<boolean>;
|
|
699
|
+
/**
|
|
700
|
+
* Write the configured InOutWRte_RvrtTms (Model 124 offset 15) to the device.
|
|
701
|
+
* Called once by `SunspecBattery.connect()` and once per recovered connection;
|
|
702
|
+
* the device keeps the value, so limit writes do not repeat it.
|
|
703
|
+
*
|
|
704
|
+
* Never throws: a device that rejects the register still takes limits, it just
|
|
705
|
+
* won't revert them on its own (the pre-existing behaviour). The first failure
|
|
706
|
+
* per unit is warned about, later ones are silent.
|
|
707
|
+
*
|
|
708
|
+
* @returns true when the value was written; false when the unit has no Model 124
|
|
709
|
+
* or the write failed.
|
|
710
|
+
*/
|
|
711
|
+
writeBatteryRateRevertTimeout(unitId: number): Promise<boolean>;
|
|
681
712
|
/**
|
|
682
713
|
* Set battery storage mode (simplified interface)
|
|
683
714
|
*/
|
|
@@ -16,7 +16,7 @@
|
|
|
16
16
|
* - pad: 0x8000 (always returns this value)
|
|
17
17
|
* - string: all registers 0x0000 (NULL)
|
|
18
18
|
*/
|
|
19
|
-
import { SunspecModelId, SunspecBatteryChargeState, SunspecStorageControlMode, SunspecChargeSource, SunspecEnableControl, SunspecStorageMode, SunspecBatteryType, SunspecBatteryBankState, DEFAULT_MODBUS_RESILIENCE_CONFIG, } from "./sunspec-interfaces.js";
|
|
19
|
+
import { SunspecModelId, SunspecBatteryChargeState, SunspecStorageControlMode, SunspecChargeSource, SunspecEnableControl, SunspecStorageMode, SunspecBatteryType, SunspecBatteryBankState, DEFAULT_MODBUS_RESILIENCE_CONFIG, DEFAULT_BATTERY_RATE_REVERT_TIMEOUT_SECONDS, MIN_BATTERY_RATE_REVERT_TIMEOUT_SECONDS, MAX_BATTERY_RATE_REVERT_TIMEOUT_SECONDS, } from "./sunspec-interfaces.js";
|
|
20
20
|
import { EnergyAppModbusConnectionHealth } from "@enyo-energy/energy-app-sdk/dist/implementations/modbus/EnergyAppModbusConnectionHealth.js";
|
|
21
21
|
import { EnergyAppModbusFaultTolerantReader } from "@enyo-energy/energy-app-sdk/dist/implementations/modbus/EnergyAppModbusFaultTolerantReader.js";
|
|
22
22
|
import { EnergyAppModbusDataTypeConverter } from "@enyo-energy/energy-app-sdk/dist/implementations/modbus/EnergyAppModbusDataTypeConverter.js";
|
|
@@ -245,6 +245,12 @@ export class SunspecModbusClient {
|
|
|
245
245
|
// announces itself twice — once by the transport, once by this client's own close/reopen —
|
|
246
246
|
// and an app must not be told to re-authenticate twice for one loss.
|
|
247
247
|
unitSessionReportedLost = new Set();
|
|
248
|
+
// Model 124 InOutWRte_RvrtTms written once when a battery connects. See
|
|
249
|
+
// setBatteryRateRevertTimeoutSeconds().
|
|
250
|
+
batteryRateRevertTimeoutSeconds = DEFAULT_BATTERY_RATE_REVERT_TIMEOUT_SECONDS;
|
|
251
|
+
// Units whose InOutWRte_RvrtTms write has already failed and been warned about. Later
|
|
252
|
+
// failures on the same unit stay silent so a device without the register warns once.
|
|
253
|
+
batteryRateRevertWarnedUnits = new Set();
|
|
248
254
|
constructor(
|
|
249
255
|
// The host application. Only used to obtain the default Modbus backend via
|
|
250
256
|
// `energyApp.useModbus()`. May be omitted (`undefined`) when a `modbusFactory` is supplied.
|
|
@@ -2507,6 +2513,32 @@ export class SunspecModbusClient {
|
|
|
2507
2513
|
return null;
|
|
2508
2514
|
}
|
|
2509
2515
|
}
|
|
2516
|
+
/**
|
|
2517
|
+
* Set the Model 124 `InOutWRte_RvrtTms` (seconds) written once when the battery
|
|
2518
|
+
* connects and once after every reconnect — e.g. 30 or 60. When no fresh rate write arrives within this window
|
|
2519
|
+
* the device drops the limit and manages itself again, so a hub that goes
|
|
2520
|
+
* offline cannot leave the battery blocked. The schedule handler refreshes an
|
|
2521
|
+
* active limit every third of this value.
|
|
2522
|
+
*
|
|
2523
|
+
* Call before `SunspecBattery.connect()`; a later change only reaches the
|
|
2524
|
+
* device on the next {@link writeBatteryRateRevertTimeout}. Must be an integer between
|
|
2525
|
+
* {@link MIN_BATTERY_RATE_REVERT_TIMEOUT_SECONDS} and
|
|
2526
|
+
* {@link MAX_BATTERY_RATE_REVERT_TIMEOUT_SECONDS}; 0 ("never revert") is
|
|
2527
|
+
* deliberately not accepted.
|
|
2528
|
+
*/
|
|
2529
|
+
setBatteryRateRevertTimeoutSeconds(seconds) {
|
|
2530
|
+
if (!Number.isInteger(seconds)
|
|
2531
|
+
|| seconds < MIN_BATTERY_RATE_REVERT_TIMEOUT_SECONDS
|
|
2532
|
+
|| seconds > MAX_BATTERY_RATE_REVERT_TIMEOUT_SECONDS) {
|
|
2533
|
+
throw new Error(`setBatteryRateRevertTimeoutSeconds: ${seconds} must be an integer between ` +
|
|
2534
|
+
`${MIN_BATTERY_RATE_REVERT_TIMEOUT_SECONDS} and ${MAX_BATTERY_RATE_REVERT_TIMEOUT_SECONDS}`);
|
|
2535
|
+
}
|
|
2536
|
+
this.batteryRateRevertTimeoutSeconds = seconds;
|
|
2537
|
+
}
|
|
2538
|
+
/** Current Model 124 `InOutWRte_RvrtTms` in seconds. */
|
|
2539
|
+
getBatteryRateRevertTimeoutSeconds() {
|
|
2540
|
+
return this.batteryRateRevertTimeoutSeconds;
|
|
2541
|
+
}
|
|
2510
2542
|
/**
|
|
2511
2543
|
* Write battery control settings to Model 124
|
|
2512
2544
|
*/
|
|
@@ -2589,6 +2621,40 @@ export class SunspecModbusClient {
|
|
|
2589
2621
|
return false;
|
|
2590
2622
|
}
|
|
2591
2623
|
}
|
|
2624
|
+
/**
|
|
2625
|
+
* Write the configured InOutWRte_RvrtTms (Model 124 offset 15) to the device.
|
|
2626
|
+
* Called once by `SunspecBattery.connect()` and once per recovered connection;
|
|
2627
|
+
* the device keeps the value, so limit writes do not repeat it.
|
|
2628
|
+
*
|
|
2629
|
+
* Never throws: a device that rejects the register still takes limits, it just
|
|
2630
|
+
* won't revert them on its own (the pre-existing behaviour). The first failure
|
|
2631
|
+
* per unit is warned about, later ones are silent.
|
|
2632
|
+
*
|
|
2633
|
+
* @returns true when the value was written; false when the unit has no Model 124
|
|
2634
|
+
* or the write failed.
|
|
2635
|
+
*/
|
|
2636
|
+
async writeBatteryRateRevertTimeout(unitId) {
|
|
2637
|
+
const model = this.findModel(unitId, SunspecModelId.Battery);
|
|
2638
|
+
if (!model) {
|
|
2639
|
+
// 802-only batteries have no Model 124 and therefore nothing to revert.
|
|
2640
|
+
console.debug(`Battery model 124 not found on unit ${unitId}, skipping InOutWRte_RvrtTms`);
|
|
2641
|
+
return false;
|
|
2642
|
+
}
|
|
2643
|
+
const seconds = this.batteryRateRevertTimeoutSeconds;
|
|
2644
|
+
try {
|
|
2645
|
+
await this.writeRegisterValue(unitId, model.address + 15, seconds, 'uint16');
|
|
2646
|
+
console.log(`Unit ${unitId}: set battery rate revert timeout (InOutWRte_RvrtTms) to ${seconds}s`);
|
|
2647
|
+
return true;
|
|
2648
|
+
}
|
|
2649
|
+
catch (error) {
|
|
2650
|
+
if (!this.batteryRateRevertWarnedUnits.has(unitId)) {
|
|
2651
|
+
this.batteryRateRevertWarnedUnits.add(unitId);
|
|
2652
|
+
console.warn(`Unit ${unitId}: writing InOutWRte_RvrtTms=${seconds}s failed, battery limits will not ` +
|
|
2653
|
+
`auto-revert on this device: ${error instanceof Error ? error.message : String(error)}`);
|
|
2654
|
+
}
|
|
2655
|
+
return false;
|
|
2656
|
+
}
|
|
2657
|
+
}
|
|
2592
2658
|
/**
|
|
2593
2659
|
* Set battery storage mode (simplified interface)
|
|
2594
2660
|
*/
|
package/dist/version.d.ts
CHANGED
package/dist/version.js
CHANGED
package/package.json
CHANGED
|
@@ -1,6 +1,6 @@
|
|
|
1
1
|
{
|
|
2
2
|
"name": "@enyo-energy/sunspec-sdk",
|
|
3
|
-
"version": "1.
|
|
3
|
+
"version": "1.4.0",
|
|
4
4
|
"description": "enyo Energy Sunspec SDK",
|
|
5
5
|
"type": "module",
|
|
6
6
|
"main": "dist/index.js",
|
|
@@ -41,7 +41,7 @@
|
|
|
41
41
|
},
|
|
42
42
|
"dependencies": {
|
|
43
43
|
"@enyo-energy/appliance-calibration": "0.0.3",
|
|
44
|
-
"@enyo-energy/energy-app-sdk": "1.
|
|
44
|
+
"@enyo-energy/energy-app-sdk": "1.30.0"
|
|
45
45
|
},
|
|
46
46
|
"volta": {
|
|
47
47
|
"node": "22.17.0"
|