@enyo-energy/sunspec-sdk 1.12.0 → 1.13.0
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/dist/cjs/sunspec-devices.cjs +86 -18
- package/dist/cjs/sunspec-devices.d.cts +35 -8
- package/dist/cjs/sunspec-interfaces.cjs +1 -1
- package/dist/cjs/sunspec-interfaces.d.cts +2 -2
- package/dist/cjs/sunspec-modbus-client.cjs +1 -1
- package/dist/cjs/version.cjs +1 -1
- package/dist/cjs/version.d.cts +1 -1
- package/dist/sunspec-devices.d.ts +35 -8
- package/dist/sunspec-devices.js +85 -18
- package/dist/sunspec-interfaces.d.ts +2 -2
- package/dist/sunspec-interfaces.js +1 -1
- package/dist/sunspec-modbus-client.js +1 -1
- package/dist/version.d.ts +1 -1
- package/dist/version.js +1 -1
- package/package.json +2 -2
|
@@ -3,6 +3,7 @@ Object.defineProperty(exports, "__esModule", { value: true });
|
|
|
3
3
|
exports.SunspecCustomDevice = exports.SunspecMeter = exports.SunspecBattery = exports.SunspecInverter = exports.BaseSunspecDevice = void 0;
|
|
4
4
|
exports.detectFeaturesFromRegisters = detectFeaturesFromRegisters;
|
|
5
5
|
exports.ratedDischargePowerW = ratedDischargePowerW;
|
|
6
|
+
exports.mpptStorageStringKind = mpptStorageStringKind;
|
|
6
7
|
exports.sumMpptBatteryPowerW = sumMpptBatteryPowerW;
|
|
7
8
|
exports.selectLiveBatteryPowerW = selectLiveBatteryPowerW;
|
|
8
9
|
exports.filterFeaturesByCalibrationResult = filterFeaturesByCalibrationResult;
|
|
@@ -525,10 +526,15 @@ class SunspecInverter extends BaseSunspecDevice {
|
|
|
525
526
|
* reporting Faulted. Debounces transient single-poll FAULT reads (e.g. a
|
|
526
527
|
* DC-coupled battery disturbing a string) that would otherwise oscillate
|
|
527
528
|
* the appliance status. Recovery is immediate (counter resets on the first
|
|
528
|
-
* non-fault read).
|
|
529
|
+
* non-fault read). Used when getOperatingFaultGraceMs() returns undefined.
|
|
529
530
|
*/
|
|
530
531
|
static OPERATING_FAULT_THRESHOLD = 3;
|
|
531
532
|
consecutiveOperatingFaults = 0;
|
|
533
|
+
// Poll timestamp (ms) of the first read of the current uninterrupted
|
|
534
|
+
// operatingState=FAULT run; undefined while not in FAULT. Cleared on any
|
|
535
|
+
// gap in observation (failed read, offline, reconnect) so unobserved time
|
|
536
|
+
// never counts towards getOperatingFaultGraceMs().
|
|
537
|
+
operatingFaultSinceMs;
|
|
532
538
|
// In-memory only — never persisted. See SunspecInverterErrorState.
|
|
533
539
|
errorState = { activeCodes: [], lastStatus: 'healthy' };
|
|
534
540
|
snapshotService;
|
|
@@ -723,6 +729,9 @@ class SunspecInverter extends BaseSunspecDevice {
|
|
|
723
729
|
messages.push(inverterMessage);
|
|
724
730
|
await this.detectAndEmitStatusTransition(inverterData, timestamp);
|
|
725
731
|
}
|
|
732
|
+
else {
|
|
733
|
+
this.interruptOperatingFaultRun();
|
|
734
|
+
}
|
|
726
735
|
this.consecutiveReconnectFailures = 0;
|
|
727
736
|
if (this.applianceId) {
|
|
728
737
|
const appliance = await this.applianceManager.findApplianceById(this.applianceId);
|
|
@@ -876,6 +885,34 @@ class SunspecInverter extends BaseSunspecDevice {
|
|
|
876
885
|
}
|
|
877
886
|
};
|
|
878
887
|
}
|
|
888
|
+
/**
|
|
889
|
+
* How long operatingState=7 (FAULT) must be reported without interruption
|
|
890
|
+
* before the inverter is reported Faulted, in ms. undefined (the default)
|
|
891
|
+
* keeps the poll-count debounce of OPERATING_FAULT_THRESHOLD consecutive
|
|
892
|
+
* FAULT reads. Override for vendors that report short FAULT phases without
|
|
893
|
+
* an error code while operating normally. Recovery stays immediate, and
|
|
894
|
+
* decoded event-register error bits are not affected.
|
|
895
|
+
*/
|
|
896
|
+
getOperatingFaultGraceMs() {
|
|
897
|
+
return undefined;
|
|
898
|
+
}
|
|
899
|
+
interruptOperatingFaultRun() {
|
|
900
|
+
this.operatingFaultSinceMs = undefined;
|
|
901
|
+
}
|
|
902
|
+
isOperatingFaultSustained(operatingFaultRaw, timestamp) {
|
|
903
|
+
if (!operatingFaultRaw) {
|
|
904
|
+
this.consecutiveOperatingFaults = 0;
|
|
905
|
+
this.operatingFaultSinceMs = undefined;
|
|
906
|
+
return false;
|
|
907
|
+
}
|
|
908
|
+
this.consecutiveOperatingFaults++;
|
|
909
|
+
this.operatingFaultSinceMs ??= timestamp.getTime();
|
|
910
|
+
const graceMs = this.getOperatingFaultGraceMs();
|
|
911
|
+
if (graceMs === undefined) {
|
|
912
|
+
return this.consecutiveOperatingFaults >= SunspecInverter.OPERATING_FAULT_THRESHOLD;
|
|
913
|
+
}
|
|
914
|
+
return timestamp.getTime() - this.operatingFaultSinceMs >= graceMs;
|
|
915
|
+
}
|
|
879
916
|
async detectAndEmitStatusTransition(data, timestamp) {
|
|
880
917
|
if (!this.applianceId || !this.dataBus)
|
|
881
918
|
return;
|
|
@@ -887,13 +924,13 @@ class SunspecInverter extends BaseSunspecDevice {
|
|
|
887
924
|
// no error bits) reports Healthy even if it was previously faulted.
|
|
888
925
|
//
|
|
889
926
|
// A single FAULT read is debounced: we only treat it as a fault after
|
|
890
|
-
// OPERATING_FAULT_THRESHOLD consecutive FAULT polls,
|
|
891
|
-
//
|
|
892
|
-
//
|
|
893
|
-
//
|
|
927
|
+
// OPERATING_FAULT_THRESHOLD consecutive FAULT polls (or, if the subclass
|
|
928
|
+
// sets getOperatingFaultGraceMs(), after FAULT has persisted that long),
|
|
929
|
+
// so a transient wobble (e.g. a faulted DC-coupled battery on a string)
|
|
930
|
+
// does not oscillate the status. Recovery is immediate — the debounce
|
|
931
|
+
// resets on the first non-fault read. Event-register error bits stay immediate.
|
|
894
932
|
const operatingFaultRaw = data.operatingState === sunspec_interfaces_js_1.SunspecInverterOperatingState.FAULT;
|
|
895
|
-
|
|
896
|
-
const operatingFault = this.consecutiveOperatingFaults >= SunspecInverter.OPERATING_FAULT_THRESHOLD;
|
|
933
|
+
const operatingFault = this.isOperatingFaultSustained(operatingFaultRaw, timestamp);
|
|
897
934
|
const newStatus = (codeIds.length > 0 || operatingFault)
|
|
898
935
|
? enyo_appliance_js_1.EnyoApplianceStatusEnum.Faulted
|
|
899
936
|
: enyo_appliance_js_1.EnyoApplianceStatusEnum.Healthy;
|
|
@@ -933,7 +970,12 @@ class SunspecInverter extends BaseSunspecDevice {
|
|
|
933
970
|
getRequiredModelIds() {
|
|
934
971
|
return SunspecInverter.INVERTER_MODEL_IDS;
|
|
935
972
|
}
|
|
973
|
+
async markOffline() {
|
|
974
|
+
this.interruptOperatingFaultRun();
|
|
975
|
+
await super.markOffline();
|
|
976
|
+
}
|
|
936
977
|
async onConnectionFailure(consecutiveFailures) {
|
|
978
|
+
this.interruptOperatingFaultRun();
|
|
937
979
|
if (!this.applianceId || !this.dataBus)
|
|
938
980
|
return;
|
|
939
981
|
if (consecutiveFailures < SunspecInverter.CONNECTION_FAULT_THRESHOLD)
|
|
@@ -956,6 +998,7 @@ class SunspecInverter extends BaseSunspecDevice {
|
|
|
956
998
|
};
|
|
957
999
|
}
|
|
958
1000
|
async onConnectionRestored() {
|
|
1001
|
+
this.interruptOperatingFaultRun();
|
|
959
1002
|
if (!this.applianceId || !this.dataBus)
|
|
960
1003
|
return;
|
|
961
1004
|
if (this.errorState.lastStatus !== 'connection_lost')
|
|
@@ -1203,13 +1246,14 @@ class SunspecInverter extends BaseSunspecDevice {
|
|
|
1203
1246
|
}
|
|
1204
1247
|
/**
|
|
1205
1248
|
* Map MPPT data to DC string structure for data bus
|
|
1206
|
-
* Filters out battery-related strings (StCha
|
|
1249
|
+
* Filters out battery-related strings (StCha n, StDisCha n+1; see
|
|
1250
|
+
* {@link mpptStorageStringKind})
|
|
1207
1251
|
*/
|
|
1208
1252
|
mapMPPTToStrings(mpptDataList) {
|
|
1209
1253
|
const result = [];
|
|
1210
1254
|
mpptDataList.forEach((mppt, index) => {
|
|
1211
1255
|
// Skip battery-related strings - they will be handled separately
|
|
1212
|
-
if (mppt.stringId
|
|
1256
|
+
if (mpptStorageStringKind(mppt.stringId) !== undefined) {
|
|
1213
1257
|
return;
|
|
1214
1258
|
}
|
|
1215
1259
|
// Only include strings with valid data
|
|
@@ -1428,7 +1472,7 @@ function ratedDischargePowerW(batteryData) {
|
|
|
1428
1472
|
/**
|
|
1429
1473
|
* Pick the live battery power, in preference order:
|
|
1430
1474
|
*
|
|
1431
|
-
* 1. Model 160 (MPPT) `StCha
|
|
1475
|
+
* 1. Model 160 (MPPT) `StCha n` / `StDisCha n+1` — direct DC-link reading,
|
|
1432
1476
|
* passed in as the already-summed `mpptBatteryPowerW`.
|
|
1433
1477
|
* 2. Model 802 `w` (offset 47) — surfaced as `chargePower` / `dischargePower`
|
|
1434
1478
|
* by the Model 802 path of `SunspecModbusClient.readBatteryData`.
|
|
@@ -1442,11 +1486,33 @@ function ratedDischargePowerW(batteryData) {
|
|
|
1442
1486
|
* Exported as a free function so the preference logic can be unit-tested
|
|
1443
1487
|
* without the full `SunspecBattery` scaffold.
|
|
1444
1488
|
*/
|
|
1489
|
+
/**
|
|
1490
|
+
* Classify a Model 160 module by its `IDStr` as a DC-coupled battery string.
|
|
1491
|
+
*
|
|
1492
|
+
* Fronius hybrids list the battery as two extra Model 160 modules after the PV
|
|
1493
|
+
* MPPTs: `StCha <n>` (charge power) and `StDisCha <n+1>` (discharge power). The
|
|
1494
|
+
* number is the module position, so it depends on how many PV trackers the
|
|
1495
|
+
* device has: a GEN24 Plus (2 MPPTs) reports `StCha 3` / `StDisCha 4`, a
|
|
1496
|
+
* Verto (3 MPPTs) `StCha 4` / `StDisCha 5`. Match the prefix, never the full
|
|
1497
|
+
* label, or a battery module is counted as a PV string.
|
|
1498
|
+
*
|
|
1499
|
+
* Returns `undefined` for a PV string.
|
|
1500
|
+
*/
|
|
1501
|
+
function mpptStorageStringKind(stringId) {
|
|
1502
|
+
const id = stringId?.trim() ?? '';
|
|
1503
|
+
if (/^StCha\b/i.test(id)) {
|
|
1504
|
+
return 'charge';
|
|
1505
|
+
}
|
|
1506
|
+
if (/^StDisCha\b/i.test(id)) {
|
|
1507
|
+
return 'discharge';
|
|
1508
|
+
}
|
|
1509
|
+
return undefined;
|
|
1510
|
+
}
|
|
1445
1511
|
/**
|
|
1446
1512
|
* Sum battery charge/discharge power from Model 160 MPPT strings.
|
|
1447
1513
|
*
|
|
1448
|
-
* - `StCha
|
|
1449
|
-
* - `StDisCha
|
|
1514
|
+
* - `StCha n` → charging power (added, positive)
|
|
1515
|
+
* - `StDisCha n+1` → discharging power (subtracted)
|
|
1450
1516
|
*
|
|
1451
1517
|
* The result follows the battery-power sign convention used across this file:
|
|
1452
1518
|
* positive = charging, negative = discharging. Returns `undefined` when neither
|
|
@@ -1458,10 +1524,11 @@ function ratedDischargePowerW(batteryData) {
|
|
|
1458
1524
|
function sumMpptBatteryPowerW(mpptDataList) {
|
|
1459
1525
|
let batteryPowerW;
|
|
1460
1526
|
for (const mppt of mpptDataList) {
|
|
1461
|
-
|
|
1527
|
+
const kind = mpptStorageStringKind(mppt.stringId);
|
|
1528
|
+
if (kind === 'charge' && mppt.dcPower !== undefined) {
|
|
1462
1529
|
batteryPowerW = (batteryPowerW ?? 0) + mppt.dcPower;
|
|
1463
1530
|
}
|
|
1464
|
-
else if (
|
|
1531
|
+
else if (kind === 'discharge' && mppt.dcPower !== undefined) {
|
|
1465
1532
|
batteryPowerW = (batteryPowerW ?? 0) - mppt.dcPower;
|
|
1466
1533
|
}
|
|
1467
1534
|
}
|
|
@@ -1972,8 +2039,8 @@ class SunspecBattery extends BaseSunspecDevice {
|
|
|
1972
2039
|
}
|
|
1973
2040
|
/**
|
|
1974
2041
|
* Extract battery power from MPPT strings with specific IDs
|
|
1975
|
-
* StCha
|
|
1976
|
-
* StDisCha
|
|
2042
|
+
* StCha n: Battery charging power (positive)
|
|
2043
|
+
* StDisCha n+1: Battery discharging power (negative)
|
|
1977
2044
|
*/
|
|
1978
2045
|
extractBatteryPowerFromMPPT(mpptDataList) {
|
|
1979
2046
|
return sumMpptBatteryPowerW(mpptDataList);
|
|
@@ -1985,10 +2052,11 @@ class SunspecBattery extends BaseSunspecDevice {
|
|
|
1985
2052
|
let hasCharge = false;
|
|
1986
2053
|
let hasDischarge = false;
|
|
1987
2054
|
mpptDataList.forEach((mppt) => {
|
|
1988
|
-
|
|
2055
|
+
const kind = mpptStorageStringKind(mppt.stringId);
|
|
2056
|
+
if (kind === 'charge' && mppt.dcPower !== undefined && mppt.dcPower > 0) {
|
|
1989
2057
|
hasCharge = true;
|
|
1990
2058
|
}
|
|
1991
|
-
else if (
|
|
2059
|
+
else if (kind === 'discharge' && mppt.dcPower !== undefined && mppt.dcPower > 0) {
|
|
1992
2060
|
hasDischarge = true;
|
|
1993
2061
|
}
|
|
1994
2062
|
});
|
|
@@ -223,10 +223,11 @@ export declare class SunspecInverter extends BaseSunspecDevice {
|
|
|
223
223
|
* reporting Faulted. Debounces transient single-poll FAULT reads (e.g. a
|
|
224
224
|
* DC-coupled battery disturbing a string) that would otherwise oscillate
|
|
225
225
|
* the appliance status. Recovery is immediate (counter resets on the first
|
|
226
|
-
* non-fault read).
|
|
226
|
+
* non-fault read). Used when getOperatingFaultGraceMs() returns undefined.
|
|
227
227
|
*/
|
|
228
228
|
private static readonly OPERATING_FAULT_THRESHOLD;
|
|
229
229
|
private consecutiveOperatingFaults;
|
|
230
|
+
private operatingFaultSinceMs?;
|
|
230
231
|
private errorState;
|
|
231
232
|
private snapshotService?;
|
|
232
233
|
private statusReassertedThisSession;
|
|
@@ -299,7 +300,18 @@ export declare class SunspecInverter extends BaseSunspecDevice {
|
|
|
299
300
|
protected mapVendorEventBit(_registerIndex: 1 | 2 | 3 | 4, _bit: number): EnyoApplianceErrorCode | undefined;
|
|
300
301
|
private hasErrorSetChanged;
|
|
301
302
|
private buildStatusMessage;
|
|
302
|
-
|
|
303
|
+
/**
|
|
304
|
+
* How long operatingState=7 (FAULT) must be reported without interruption
|
|
305
|
+
* before the inverter is reported Faulted, in ms. undefined (the default)
|
|
306
|
+
* keeps the poll-count debounce of OPERATING_FAULT_THRESHOLD consecutive
|
|
307
|
+
* FAULT reads. Override for vendors that report short FAULT phases without
|
|
308
|
+
* an error code while operating normally. Recovery stays immediate, and
|
|
309
|
+
* decoded event-register error bits are not affected.
|
|
310
|
+
*/
|
|
311
|
+
protected getOperatingFaultGraceMs(): number | undefined;
|
|
312
|
+
private interruptOperatingFaultRun;
|
|
313
|
+
private isOperatingFaultSustained;
|
|
314
|
+
protected detectAndEmitStatusTransition(data: SunspecInverterData, timestamp: Date): Promise<void>;
|
|
303
315
|
/**
|
|
304
316
|
* A reconnect has only recovered the inverter if discovery finds one of its
|
|
305
317
|
* data models. An SE gateway can accept the new socket and answer a partial
|
|
@@ -308,6 +320,7 @@ export declare class SunspecInverter extends BaseSunspecDevice {
|
|
|
308
320
|
* no 101/103/111/112/113 model and report 0 W. Require an actual inverter model.
|
|
309
321
|
*/
|
|
310
322
|
protected getRequiredModelIds(): readonly number[];
|
|
323
|
+
protected markOffline(): Promise<void>;
|
|
311
324
|
protected onConnectionFailure(consecutiveFailures: number): Promise<void>;
|
|
312
325
|
protected onConnectionRestored(): Promise<void>;
|
|
313
326
|
/**
|
|
@@ -422,7 +435,8 @@ export declare class SunspecInverter extends BaseSunspecDevice {
|
|
|
422
435
|
private sumDcStringsW;
|
|
423
436
|
/**
|
|
424
437
|
* Map MPPT data to DC string structure for data bus
|
|
425
|
-
* Filters out battery-related strings (StCha
|
|
438
|
+
* Filters out battery-related strings (StCha n, StDisCha n+1; see
|
|
439
|
+
* {@link mpptStorageStringKind})
|
|
426
440
|
*/
|
|
427
441
|
protected mapMPPTToStrings(mpptDataList: SunspecMPPTData[]): EnyoDataBusInverterValuesV1String[];
|
|
428
442
|
private mapMPPTOperatingState;
|
|
@@ -494,7 +508,7 @@ export declare function ratedDischargePowerW(batteryData: SunspecBatteryData | n
|
|
|
494
508
|
/**
|
|
495
509
|
* Pick the live battery power, in preference order:
|
|
496
510
|
*
|
|
497
|
-
* 1. Model 160 (MPPT) `StCha
|
|
511
|
+
* 1. Model 160 (MPPT) `StCha n` / `StDisCha n+1` — direct DC-link reading,
|
|
498
512
|
* passed in as the already-summed `mpptBatteryPowerW`.
|
|
499
513
|
* 2. Model 802 `w` (offset 47) — surfaced as `chargePower` / `dischargePower`
|
|
500
514
|
* by the Model 802 path of `SunspecModbusClient.readBatteryData`.
|
|
@@ -508,11 +522,24 @@ export declare function ratedDischargePowerW(batteryData: SunspecBatteryData | n
|
|
|
508
522
|
* Exported as a free function so the preference logic can be unit-tested
|
|
509
523
|
* without the full `SunspecBattery` scaffold.
|
|
510
524
|
*/
|
|
525
|
+
/**
|
|
526
|
+
* Classify a Model 160 module by its `IDStr` as a DC-coupled battery string.
|
|
527
|
+
*
|
|
528
|
+
* Fronius hybrids list the battery as two extra Model 160 modules after the PV
|
|
529
|
+
* MPPTs: `StCha <n>` (charge power) and `StDisCha <n+1>` (discharge power). The
|
|
530
|
+
* number is the module position, so it depends on how many PV trackers the
|
|
531
|
+
* device has: a GEN24 Plus (2 MPPTs) reports `StCha 3` / `StDisCha 4`, a
|
|
532
|
+
* Verto (3 MPPTs) `StCha 4` / `StDisCha 5`. Match the prefix, never the full
|
|
533
|
+
* label, or a battery module is counted as a PV string.
|
|
534
|
+
*
|
|
535
|
+
* Returns `undefined` for a PV string.
|
|
536
|
+
*/
|
|
537
|
+
export declare function mpptStorageStringKind(stringId: string | undefined): 'charge' | 'discharge' | undefined;
|
|
511
538
|
/**
|
|
512
539
|
* Sum battery charge/discharge power from Model 160 MPPT strings.
|
|
513
540
|
*
|
|
514
|
-
* - `StCha
|
|
515
|
-
* - `StDisCha
|
|
541
|
+
* - `StCha n` → charging power (added, positive)
|
|
542
|
+
* - `StDisCha n+1` → discharging power (subtracted)
|
|
516
543
|
*
|
|
517
544
|
* The result follows the battery-power sign convention used across this file:
|
|
518
545
|
* positive = charging, negative = discharging. Returns `undefined` when neither
|
|
@@ -677,8 +704,8 @@ export declare class SunspecBattery extends BaseSunspecDevice {
|
|
|
677
704
|
readData(clockId: string, resolution: EnyoDataBusMessageResolution): Promise<EnyoDataBusMessage[]>;
|
|
678
705
|
/**
|
|
679
706
|
* Extract battery power from MPPT strings with specific IDs
|
|
680
|
-
* StCha
|
|
681
|
-
* StDisCha
|
|
707
|
+
* StCha n: Battery charging power (positive)
|
|
708
|
+
* StDisCha n+1: Battery discharging power (negative)
|
|
682
709
|
*/
|
|
683
710
|
private extractBatteryPowerFromMPPT;
|
|
684
711
|
/**
|
|
@@ -332,7 +332,7 @@ var SunspecPvPowerSource;
|
|
|
332
332
|
* consumer can see which telemetry produced the number.
|
|
333
333
|
*
|
|
334
334
|
* - `MpptStrings`: summed per-string DC power from Model 160 (battery strings
|
|
335
|
-
* `StCha
|
|
335
|
+
* `StCha n` / `StDisCha n+1` excluded). Already pure PV — never battery-adjusted.
|
|
336
336
|
* - `InverterDc`: the inverter's total DC power (Model 101 `DCW`). Pure PV — never
|
|
337
337
|
* battery-adjusted.
|
|
338
338
|
* - `InverterAc`: the inverter's total AC power (Model 101 `W`). On a hybrid this
|
|
@@ -892,7 +892,7 @@ export declare enum SunspecPvPowerSource {
|
|
|
892
892
|
* consumer can see which telemetry produced the number.
|
|
893
893
|
*
|
|
894
894
|
* - `MpptStrings`: summed per-string DC power from Model 160 (battery strings
|
|
895
|
-
* `StCha
|
|
895
|
+
* `StCha n` / `StDisCha n+1` excluded). Already pure PV — never battery-adjusted.
|
|
896
896
|
* - `InverterDc`: the inverter's total DC power (Model 101 `DCW`). Pure PV — never
|
|
897
897
|
* battery-adjusted.
|
|
898
898
|
* - `InverterAc`: the inverter's total AC power (Model 101 `W`). On a hybrid this
|
|
@@ -932,7 +932,7 @@ export interface SunspecInverterReading {
|
|
|
932
932
|
inverterPowerWRaw: number;
|
|
933
933
|
/**
|
|
934
934
|
* Summed per-string MPPT DC power (W) from Model 160 (battery strings
|
|
935
|
-
* `StCha
|
|
935
|
+
* `StCha n` / `StDisCha n+1` excluded), clamped to ≥ 0. Always computed and
|
|
936
936
|
* reported independently of `powerOrigin` — `0` when no PV strings are readable.
|
|
937
937
|
*/
|
|
938
938
|
inverterPowerWDcStrings: number;
|
|
@@ -2494,7 +2494,7 @@ class SunspecModbusClient {
|
|
|
2494
2494
|
// a live measurement — and produces e.g. 5000 W of "charging"
|
|
2495
2495
|
// for an idle battery with inWRte = 100 % and a 5 kW nameplate.
|
|
2496
2496
|
// Live battery power must come from a real source: Model 160
|
|
2497
|
-
// StCha
|
|
2497
|
+
// StCha n / StDisCha n+1 (see SunspecBattery.extractBatteryPower
|
|
2498
2498
|
// FromMPPT) or Model 802 `w` at offset 47 (the Model 802 branch
|
|
2499
2499
|
// of this method, just below). Model-124-only devices should
|
|
2500
2500
|
// publish "no signal" rather than the commanded cap.
|
package/dist/cjs/version.cjs
CHANGED
|
@@ -9,7 +9,7 @@ exports.getSdkVersion = getSdkVersion;
|
|
|
9
9
|
/**
|
|
10
10
|
* Current version of the enyo Energy App SDK.
|
|
11
11
|
*/
|
|
12
|
-
exports.SDK_VERSION = '1.
|
|
12
|
+
exports.SDK_VERSION = '1.13.0';
|
|
13
13
|
/**
|
|
14
14
|
* Gets the current SDK version.
|
|
15
15
|
* @returns The semantic version string of the SDK
|
package/dist/cjs/version.d.cts
CHANGED
|
@@ -223,10 +223,11 @@ export declare class SunspecInverter extends BaseSunspecDevice {
|
|
|
223
223
|
* reporting Faulted. Debounces transient single-poll FAULT reads (e.g. a
|
|
224
224
|
* DC-coupled battery disturbing a string) that would otherwise oscillate
|
|
225
225
|
* the appliance status. Recovery is immediate (counter resets on the first
|
|
226
|
-
* non-fault read).
|
|
226
|
+
* non-fault read). Used when getOperatingFaultGraceMs() returns undefined.
|
|
227
227
|
*/
|
|
228
228
|
private static readonly OPERATING_FAULT_THRESHOLD;
|
|
229
229
|
private consecutiveOperatingFaults;
|
|
230
|
+
private operatingFaultSinceMs?;
|
|
230
231
|
private errorState;
|
|
231
232
|
private snapshotService?;
|
|
232
233
|
private statusReassertedThisSession;
|
|
@@ -299,7 +300,18 @@ export declare class SunspecInverter extends BaseSunspecDevice {
|
|
|
299
300
|
protected mapVendorEventBit(_registerIndex: 1 | 2 | 3 | 4, _bit: number): EnyoApplianceErrorCode | undefined;
|
|
300
301
|
private hasErrorSetChanged;
|
|
301
302
|
private buildStatusMessage;
|
|
302
|
-
|
|
303
|
+
/**
|
|
304
|
+
* How long operatingState=7 (FAULT) must be reported without interruption
|
|
305
|
+
* before the inverter is reported Faulted, in ms. undefined (the default)
|
|
306
|
+
* keeps the poll-count debounce of OPERATING_FAULT_THRESHOLD consecutive
|
|
307
|
+
* FAULT reads. Override for vendors that report short FAULT phases without
|
|
308
|
+
* an error code while operating normally. Recovery stays immediate, and
|
|
309
|
+
* decoded event-register error bits are not affected.
|
|
310
|
+
*/
|
|
311
|
+
protected getOperatingFaultGraceMs(): number | undefined;
|
|
312
|
+
private interruptOperatingFaultRun;
|
|
313
|
+
private isOperatingFaultSustained;
|
|
314
|
+
protected detectAndEmitStatusTransition(data: SunspecInverterData, timestamp: Date): Promise<void>;
|
|
303
315
|
/**
|
|
304
316
|
* A reconnect has only recovered the inverter if discovery finds one of its
|
|
305
317
|
* data models. An SE gateway can accept the new socket and answer a partial
|
|
@@ -308,6 +320,7 @@ export declare class SunspecInverter extends BaseSunspecDevice {
|
|
|
308
320
|
* no 101/103/111/112/113 model and report 0 W. Require an actual inverter model.
|
|
309
321
|
*/
|
|
310
322
|
protected getRequiredModelIds(): readonly number[];
|
|
323
|
+
protected markOffline(): Promise<void>;
|
|
311
324
|
protected onConnectionFailure(consecutiveFailures: number): Promise<void>;
|
|
312
325
|
protected onConnectionRestored(): Promise<void>;
|
|
313
326
|
/**
|
|
@@ -422,7 +435,8 @@ export declare class SunspecInverter extends BaseSunspecDevice {
|
|
|
422
435
|
private sumDcStringsW;
|
|
423
436
|
/**
|
|
424
437
|
* Map MPPT data to DC string structure for data bus
|
|
425
|
-
* Filters out battery-related strings (StCha
|
|
438
|
+
* Filters out battery-related strings (StCha n, StDisCha n+1; see
|
|
439
|
+
* {@link mpptStorageStringKind})
|
|
426
440
|
*/
|
|
427
441
|
protected mapMPPTToStrings(mpptDataList: SunspecMPPTData[]): EnyoDataBusInverterValuesV1String[];
|
|
428
442
|
private mapMPPTOperatingState;
|
|
@@ -494,7 +508,7 @@ export declare function ratedDischargePowerW(batteryData: SunspecBatteryData | n
|
|
|
494
508
|
/**
|
|
495
509
|
* Pick the live battery power, in preference order:
|
|
496
510
|
*
|
|
497
|
-
* 1. Model 160 (MPPT) `StCha
|
|
511
|
+
* 1. Model 160 (MPPT) `StCha n` / `StDisCha n+1` — direct DC-link reading,
|
|
498
512
|
* passed in as the already-summed `mpptBatteryPowerW`.
|
|
499
513
|
* 2. Model 802 `w` (offset 47) — surfaced as `chargePower` / `dischargePower`
|
|
500
514
|
* by the Model 802 path of `SunspecModbusClient.readBatteryData`.
|
|
@@ -508,11 +522,24 @@ export declare function ratedDischargePowerW(batteryData: SunspecBatteryData | n
|
|
|
508
522
|
* Exported as a free function so the preference logic can be unit-tested
|
|
509
523
|
* without the full `SunspecBattery` scaffold.
|
|
510
524
|
*/
|
|
525
|
+
/**
|
|
526
|
+
* Classify a Model 160 module by its `IDStr` as a DC-coupled battery string.
|
|
527
|
+
*
|
|
528
|
+
* Fronius hybrids list the battery as two extra Model 160 modules after the PV
|
|
529
|
+
* MPPTs: `StCha <n>` (charge power) and `StDisCha <n+1>` (discharge power). The
|
|
530
|
+
* number is the module position, so it depends on how many PV trackers the
|
|
531
|
+
* device has: a GEN24 Plus (2 MPPTs) reports `StCha 3` / `StDisCha 4`, a
|
|
532
|
+
* Verto (3 MPPTs) `StCha 4` / `StDisCha 5`. Match the prefix, never the full
|
|
533
|
+
* label, or a battery module is counted as a PV string.
|
|
534
|
+
*
|
|
535
|
+
* Returns `undefined` for a PV string.
|
|
536
|
+
*/
|
|
537
|
+
export declare function mpptStorageStringKind(stringId: string | undefined): 'charge' | 'discharge' | undefined;
|
|
511
538
|
/**
|
|
512
539
|
* Sum battery charge/discharge power from Model 160 MPPT strings.
|
|
513
540
|
*
|
|
514
|
-
* - `StCha
|
|
515
|
-
* - `StDisCha
|
|
541
|
+
* - `StCha n` → charging power (added, positive)
|
|
542
|
+
* - `StDisCha n+1` → discharging power (subtracted)
|
|
516
543
|
*
|
|
517
544
|
* The result follows the battery-power sign convention used across this file:
|
|
518
545
|
* positive = charging, negative = discharging. Returns `undefined` when neither
|
|
@@ -677,8 +704,8 @@ export declare class SunspecBattery extends BaseSunspecDevice {
|
|
|
677
704
|
readData(clockId: string, resolution: EnyoDataBusMessageResolution): Promise<EnyoDataBusMessage[]>;
|
|
678
705
|
/**
|
|
679
706
|
* Extract battery power from MPPT strings with specific IDs
|
|
680
|
-
* StCha
|
|
681
|
-
* StDisCha
|
|
707
|
+
* StCha n: Battery charging power (positive)
|
|
708
|
+
* StDisCha n+1: Battery discharging power (negative)
|
|
682
709
|
*/
|
|
683
710
|
private extractBatteryPowerFromMPPT;
|
|
684
711
|
/**
|
package/dist/sunspec-devices.js
CHANGED
|
@@ -515,10 +515,15 @@ export class SunspecInverter extends BaseSunspecDevice {
|
|
|
515
515
|
* reporting Faulted. Debounces transient single-poll FAULT reads (e.g. a
|
|
516
516
|
* DC-coupled battery disturbing a string) that would otherwise oscillate
|
|
517
517
|
* the appliance status. Recovery is immediate (counter resets on the first
|
|
518
|
-
* non-fault read).
|
|
518
|
+
* non-fault read). Used when getOperatingFaultGraceMs() returns undefined.
|
|
519
519
|
*/
|
|
520
520
|
static OPERATING_FAULT_THRESHOLD = 3;
|
|
521
521
|
consecutiveOperatingFaults = 0;
|
|
522
|
+
// Poll timestamp (ms) of the first read of the current uninterrupted
|
|
523
|
+
// operatingState=FAULT run; undefined while not in FAULT. Cleared on any
|
|
524
|
+
// gap in observation (failed read, offline, reconnect) so unobserved time
|
|
525
|
+
// never counts towards getOperatingFaultGraceMs().
|
|
526
|
+
operatingFaultSinceMs;
|
|
522
527
|
// In-memory only — never persisted. See SunspecInverterErrorState.
|
|
523
528
|
errorState = { activeCodes: [], lastStatus: 'healthy' };
|
|
524
529
|
snapshotService;
|
|
@@ -713,6 +718,9 @@ export class SunspecInverter extends BaseSunspecDevice {
|
|
|
713
718
|
messages.push(inverterMessage);
|
|
714
719
|
await this.detectAndEmitStatusTransition(inverterData, timestamp);
|
|
715
720
|
}
|
|
721
|
+
else {
|
|
722
|
+
this.interruptOperatingFaultRun();
|
|
723
|
+
}
|
|
716
724
|
this.consecutiveReconnectFailures = 0;
|
|
717
725
|
if (this.applianceId) {
|
|
718
726
|
const appliance = await this.applianceManager.findApplianceById(this.applianceId);
|
|
@@ -866,6 +874,34 @@ export class SunspecInverter extends BaseSunspecDevice {
|
|
|
866
874
|
}
|
|
867
875
|
};
|
|
868
876
|
}
|
|
877
|
+
/**
|
|
878
|
+
* How long operatingState=7 (FAULT) must be reported without interruption
|
|
879
|
+
* before the inverter is reported Faulted, in ms. undefined (the default)
|
|
880
|
+
* keeps the poll-count debounce of OPERATING_FAULT_THRESHOLD consecutive
|
|
881
|
+
* FAULT reads. Override for vendors that report short FAULT phases without
|
|
882
|
+
* an error code while operating normally. Recovery stays immediate, and
|
|
883
|
+
* decoded event-register error bits are not affected.
|
|
884
|
+
*/
|
|
885
|
+
getOperatingFaultGraceMs() {
|
|
886
|
+
return undefined;
|
|
887
|
+
}
|
|
888
|
+
interruptOperatingFaultRun() {
|
|
889
|
+
this.operatingFaultSinceMs = undefined;
|
|
890
|
+
}
|
|
891
|
+
isOperatingFaultSustained(operatingFaultRaw, timestamp) {
|
|
892
|
+
if (!operatingFaultRaw) {
|
|
893
|
+
this.consecutiveOperatingFaults = 0;
|
|
894
|
+
this.operatingFaultSinceMs = undefined;
|
|
895
|
+
return false;
|
|
896
|
+
}
|
|
897
|
+
this.consecutiveOperatingFaults++;
|
|
898
|
+
this.operatingFaultSinceMs ??= timestamp.getTime();
|
|
899
|
+
const graceMs = this.getOperatingFaultGraceMs();
|
|
900
|
+
if (graceMs === undefined) {
|
|
901
|
+
return this.consecutiveOperatingFaults >= SunspecInverter.OPERATING_FAULT_THRESHOLD;
|
|
902
|
+
}
|
|
903
|
+
return timestamp.getTime() - this.operatingFaultSinceMs >= graceMs;
|
|
904
|
+
}
|
|
869
905
|
async detectAndEmitStatusTransition(data, timestamp) {
|
|
870
906
|
if (!this.applianceId || !this.dataBus)
|
|
871
907
|
return;
|
|
@@ -877,13 +913,13 @@ export class SunspecInverter extends BaseSunspecDevice {
|
|
|
877
913
|
// no error bits) reports Healthy even if it was previously faulted.
|
|
878
914
|
//
|
|
879
915
|
// A single FAULT read is debounced: we only treat it as a fault after
|
|
880
|
-
// OPERATING_FAULT_THRESHOLD consecutive FAULT polls,
|
|
881
|
-
//
|
|
882
|
-
//
|
|
883
|
-
//
|
|
916
|
+
// OPERATING_FAULT_THRESHOLD consecutive FAULT polls (or, if the subclass
|
|
917
|
+
// sets getOperatingFaultGraceMs(), after FAULT has persisted that long),
|
|
918
|
+
// so a transient wobble (e.g. a faulted DC-coupled battery on a string)
|
|
919
|
+
// does not oscillate the status. Recovery is immediate — the debounce
|
|
920
|
+
// resets on the first non-fault read. Event-register error bits stay immediate.
|
|
884
921
|
const operatingFaultRaw = data.operatingState === SunspecInverterOperatingState.FAULT;
|
|
885
|
-
|
|
886
|
-
const operatingFault = this.consecutiveOperatingFaults >= SunspecInverter.OPERATING_FAULT_THRESHOLD;
|
|
922
|
+
const operatingFault = this.isOperatingFaultSustained(operatingFaultRaw, timestamp);
|
|
887
923
|
const newStatus = (codeIds.length > 0 || operatingFault)
|
|
888
924
|
? EnyoApplianceStatusEnum.Faulted
|
|
889
925
|
: EnyoApplianceStatusEnum.Healthy;
|
|
@@ -923,7 +959,12 @@ export class SunspecInverter extends BaseSunspecDevice {
|
|
|
923
959
|
getRequiredModelIds() {
|
|
924
960
|
return SunspecInverter.INVERTER_MODEL_IDS;
|
|
925
961
|
}
|
|
962
|
+
async markOffline() {
|
|
963
|
+
this.interruptOperatingFaultRun();
|
|
964
|
+
await super.markOffline();
|
|
965
|
+
}
|
|
926
966
|
async onConnectionFailure(consecutiveFailures) {
|
|
967
|
+
this.interruptOperatingFaultRun();
|
|
927
968
|
if (!this.applianceId || !this.dataBus)
|
|
928
969
|
return;
|
|
929
970
|
if (consecutiveFailures < SunspecInverter.CONNECTION_FAULT_THRESHOLD)
|
|
@@ -946,6 +987,7 @@ export class SunspecInverter extends BaseSunspecDevice {
|
|
|
946
987
|
};
|
|
947
988
|
}
|
|
948
989
|
async onConnectionRestored() {
|
|
990
|
+
this.interruptOperatingFaultRun();
|
|
949
991
|
if (!this.applianceId || !this.dataBus)
|
|
950
992
|
return;
|
|
951
993
|
if (this.errorState.lastStatus !== 'connection_lost')
|
|
@@ -1193,13 +1235,14 @@ export class SunspecInverter extends BaseSunspecDevice {
|
|
|
1193
1235
|
}
|
|
1194
1236
|
/**
|
|
1195
1237
|
* Map MPPT data to DC string structure for data bus
|
|
1196
|
-
* Filters out battery-related strings (StCha
|
|
1238
|
+
* Filters out battery-related strings (StCha n, StDisCha n+1; see
|
|
1239
|
+
* {@link mpptStorageStringKind})
|
|
1197
1240
|
*/
|
|
1198
1241
|
mapMPPTToStrings(mpptDataList) {
|
|
1199
1242
|
const result = [];
|
|
1200
1243
|
mpptDataList.forEach((mppt, index) => {
|
|
1201
1244
|
// Skip battery-related strings - they will be handled separately
|
|
1202
|
-
if (mppt.stringId
|
|
1245
|
+
if (mpptStorageStringKind(mppt.stringId) !== undefined) {
|
|
1203
1246
|
return;
|
|
1204
1247
|
}
|
|
1205
1248
|
// Only include strings with valid data
|
|
@@ -1417,7 +1460,7 @@ export function ratedDischargePowerW(batteryData) {
|
|
|
1417
1460
|
/**
|
|
1418
1461
|
* Pick the live battery power, in preference order:
|
|
1419
1462
|
*
|
|
1420
|
-
* 1. Model 160 (MPPT) `StCha
|
|
1463
|
+
* 1. Model 160 (MPPT) `StCha n` / `StDisCha n+1` — direct DC-link reading,
|
|
1421
1464
|
* passed in as the already-summed `mpptBatteryPowerW`.
|
|
1422
1465
|
* 2. Model 802 `w` (offset 47) — surfaced as `chargePower` / `dischargePower`
|
|
1423
1466
|
* by the Model 802 path of `SunspecModbusClient.readBatteryData`.
|
|
@@ -1431,11 +1474,33 @@ export function ratedDischargePowerW(batteryData) {
|
|
|
1431
1474
|
* Exported as a free function so the preference logic can be unit-tested
|
|
1432
1475
|
* without the full `SunspecBattery` scaffold.
|
|
1433
1476
|
*/
|
|
1477
|
+
/**
|
|
1478
|
+
* Classify a Model 160 module by its `IDStr` as a DC-coupled battery string.
|
|
1479
|
+
*
|
|
1480
|
+
* Fronius hybrids list the battery as two extra Model 160 modules after the PV
|
|
1481
|
+
* MPPTs: `StCha <n>` (charge power) and `StDisCha <n+1>` (discharge power). The
|
|
1482
|
+
* number is the module position, so it depends on how many PV trackers the
|
|
1483
|
+
* device has: a GEN24 Plus (2 MPPTs) reports `StCha 3` / `StDisCha 4`, a
|
|
1484
|
+
* Verto (3 MPPTs) `StCha 4` / `StDisCha 5`. Match the prefix, never the full
|
|
1485
|
+
* label, or a battery module is counted as a PV string.
|
|
1486
|
+
*
|
|
1487
|
+
* Returns `undefined` for a PV string.
|
|
1488
|
+
*/
|
|
1489
|
+
export function mpptStorageStringKind(stringId) {
|
|
1490
|
+
const id = stringId?.trim() ?? '';
|
|
1491
|
+
if (/^StCha\b/i.test(id)) {
|
|
1492
|
+
return 'charge';
|
|
1493
|
+
}
|
|
1494
|
+
if (/^StDisCha\b/i.test(id)) {
|
|
1495
|
+
return 'discharge';
|
|
1496
|
+
}
|
|
1497
|
+
return undefined;
|
|
1498
|
+
}
|
|
1434
1499
|
/**
|
|
1435
1500
|
* Sum battery charge/discharge power from Model 160 MPPT strings.
|
|
1436
1501
|
*
|
|
1437
|
-
* - `StCha
|
|
1438
|
-
* - `StDisCha
|
|
1502
|
+
* - `StCha n` → charging power (added, positive)
|
|
1503
|
+
* - `StDisCha n+1` → discharging power (subtracted)
|
|
1439
1504
|
*
|
|
1440
1505
|
* The result follows the battery-power sign convention used across this file:
|
|
1441
1506
|
* positive = charging, negative = discharging. Returns `undefined` when neither
|
|
@@ -1447,10 +1512,11 @@ export function ratedDischargePowerW(batteryData) {
|
|
|
1447
1512
|
export function sumMpptBatteryPowerW(mpptDataList) {
|
|
1448
1513
|
let batteryPowerW;
|
|
1449
1514
|
for (const mppt of mpptDataList) {
|
|
1450
|
-
|
|
1515
|
+
const kind = mpptStorageStringKind(mppt.stringId);
|
|
1516
|
+
if (kind === 'charge' && mppt.dcPower !== undefined) {
|
|
1451
1517
|
batteryPowerW = (batteryPowerW ?? 0) + mppt.dcPower;
|
|
1452
1518
|
}
|
|
1453
|
-
else if (
|
|
1519
|
+
else if (kind === 'discharge' && mppt.dcPower !== undefined) {
|
|
1454
1520
|
batteryPowerW = (batteryPowerW ?? 0) - mppt.dcPower;
|
|
1455
1521
|
}
|
|
1456
1522
|
}
|
|
@@ -1961,8 +2027,8 @@ export class SunspecBattery extends BaseSunspecDevice {
|
|
|
1961
2027
|
}
|
|
1962
2028
|
/**
|
|
1963
2029
|
* Extract battery power from MPPT strings with specific IDs
|
|
1964
|
-
* StCha
|
|
1965
|
-
* StDisCha
|
|
2030
|
+
* StCha n: Battery charging power (positive)
|
|
2031
|
+
* StDisCha n+1: Battery discharging power (negative)
|
|
1966
2032
|
*/
|
|
1967
2033
|
extractBatteryPowerFromMPPT(mpptDataList) {
|
|
1968
2034
|
return sumMpptBatteryPowerW(mpptDataList);
|
|
@@ -1974,10 +2040,11 @@ export class SunspecBattery extends BaseSunspecDevice {
|
|
|
1974
2040
|
let hasCharge = false;
|
|
1975
2041
|
let hasDischarge = false;
|
|
1976
2042
|
mpptDataList.forEach((mppt) => {
|
|
1977
|
-
|
|
2043
|
+
const kind = mpptStorageStringKind(mppt.stringId);
|
|
2044
|
+
if (kind === 'charge' && mppt.dcPower !== undefined && mppt.dcPower > 0) {
|
|
1978
2045
|
hasCharge = true;
|
|
1979
2046
|
}
|
|
1980
|
-
else if (
|
|
2047
|
+
else if (kind === 'discharge' && mppt.dcPower !== undefined && mppt.dcPower > 0) {
|
|
1981
2048
|
hasDischarge = true;
|
|
1982
2049
|
}
|
|
1983
2050
|
});
|
|
@@ -892,7 +892,7 @@ export declare enum SunspecPvPowerSource {
|
|
|
892
892
|
* consumer can see which telemetry produced the number.
|
|
893
893
|
*
|
|
894
894
|
* - `MpptStrings`: summed per-string DC power from Model 160 (battery strings
|
|
895
|
-
* `StCha
|
|
895
|
+
* `StCha n` / `StDisCha n+1` excluded). Already pure PV — never battery-adjusted.
|
|
896
896
|
* - `InverterDc`: the inverter's total DC power (Model 101 `DCW`). Pure PV — never
|
|
897
897
|
* battery-adjusted.
|
|
898
898
|
* - `InverterAc`: the inverter's total AC power (Model 101 `W`). On a hybrid this
|
|
@@ -932,7 +932,7 @@ export interface SunspecInverterReading {
|
|
|
932
932
|
inverterPowerWRaw: number;
|
|
933
933
|
/**
|
|
934
934
|
* Summed per-string MPPT DC power (W) from Model 160 (battery strings
|
|
935
|
-
* `StCha
|
|
935
|
+
* `StCha n` / `StDisCha n+1` excluded), clamped to ≥ 0. Always computed and
|
|
936
936
|
* reported independently of `powerOrigin` — `0` when no PV strings are readable.
|
|
937
937
|
*/
|
|
938
938
|
inverterPowerWDcStrings: number;
|
|
@@ -329,7 +329,7 @@ export var SunspecPvPowerSource;
|
|
|
329
329
|
* consumer can see which telemetry produced the number.
|
|
330
330
|
*
|
|
331
331
|
* - `MpptStrings`: summed per-string DC power from Model 160 (battery strings
|
|
332
|
-
* `StCha
|
|
332
|
+
* `StCha n` / `StDisCha n+1` excluded). Already pure PV — never battery-adjusted.
|
|
333
333
|
* - `InverterDc`: the inverter's total DC power (Model 101 `DCW`). Pure PV — never
|
|
334
334
|
* battery-adjusted.
|
|
335
335
|
* - `InverterAc`: the inverter's total AC power (Model 101 `W`). On a hybrid this
|
|
@@ -2485,7 +2485,7 @@ export class SunspecModbusClient {
|
|
|
2485
2485
|
// a live measurement — and produces e.g. 5000 W of "charging"
|
|
2486
2486
|
// for an idle battery with inWRte = 100 % and a 5 kW nameplate.
|
|
2487
2487
|
// Live battery power must come from a real source: Model 160
|
|
2488
|
-
// StCha
|
|
2488
|
+
// StCha n / StDisCha n+1 (see SunspecBattery.extractBatteryPower
|
|
2489
2489
|
// FromMPPT) or Model 802 `w` at offset 47 (the Model 802 branch
|
|
2490
2490
|
// of this method, just below). Model-124-only devices should
|
|
2491
2491
|
// publish "no signal" rather than the commanded cap.
|
package/dist/version.d.ts
CHANGED
package/dist/version.js
CHANGED
package/package.json
CHANGED
|
@@ -1,6 +1,6 @@
|
|
|
1
1
|
{
|
|
2
2
|
"name": "@enyo-energy/sunspec-sdk",
|
|
3
|
-
"version": "1.
|
|
3
|
+
"version": "1.13.0",
|
|
4
4
|
"description": "enyo Energy Sunspec SDK",
|
|
5
5
|
"type": "module",
|
|
6
6
|
"main": "dist/index.js",
|
|
@@ -42,7 +42,7 @@
|
|
|
42
42
|
},
|
|
43
43
|
"dependencies": {
|
|
44
44
|
"@enyo-energy/appliance-calibration": "0.0.3",
|
|
45
|
-
"@enyo-energy/energy-app-sdk": "1.
|
|
45
|
+
"@enyo-energy/energy-app-sdk": "1.70.0"
|
|
46
46
|
},
|
|
47
47
|
"volta": {
|
|
48
48
|
"node": "22.17.0"
|