@enyo-energy/sunspec-sdk 1.0.1 → 1.1.0

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
package/README.md CHANGED
@@ -10,6 +10,7 @@ SunSpec Modbus client for reading data from solar inverters, batteries, meters,
10
10
  - [Storage Schedule Control](#storage-schedule-control)
11
11
  - [Connection Failures and Logging](#connection-failures-and-logging)
12
12
  - [Transport Options](#transport-options)
13
+ - [Vendor Function Codes and Connection-Scoped Permission](#vendor-function-codes-and-connection-scoped-permission)
13
14
  - [Appliance Metadata the Registers Don't Carry](#appliance-metadata-the-registers-dont-carry)
14
15
  - [How Addressing Works](#how-addressing-works)
15
16
  - [Bulk Register Reading](#bulk-register-reading)
@@ -416,6 +417,63 @@ The config is applied when the client for a `host:port` is **first created**; a
416
417
 
417
418
  ---
418
419
 
420
+ ## Vendor Function Codes and Connection-Scoped Permission
421
+
422
+ Some devices refuse control until a proprietary handshake has succeeded, over a function code
423
+ outside the standard eight. The canonical case is a Huawei SUN2000 with a LUNA2000 and no EMMA:
424
+ its control registers are ordinary holding registers, but every write comes back with exception
425
+ `0x80` — *"an operation is not allowed because of a permission authentication failure or
426
+ permission expiration"* — until an installer login has gone out over Huawei's function code
427
+ `0x41`.
428
+
429
+ Two methods cover that, both vendor-agnostic. Sub-commands, credential digests and keepalives
430
+ belong to the consumer; the SDK contributes the socket discipline.
431
+
432
+ ### `sendRawPdu(unitId, functionCode, payload)`
433
+
434
+ Puts one PDU on the wire verbatim and returns the raw answer. It runs **inside the unit's
435
+ transaction chain**, exactly like `readRegisterBlock` — so a handshake can never cross frames with
436
+ a poll already in flight, which is what the single-frame SDongles behind these devices require.
437
+
438
+ ```ts
439
+ const challenge = await client.sendRawPdu(unitId, 0x41, Buffer.from([0x24]));
440
+ const accepted = await client.sendRawPdu(unitId, 0x41, Buffer.concat([Buffer.from([0x25]), digest]));
441
+ ```
442
+
443
+ A device exception arrives as **data**, on `response.exceptionCode`, not as a rejection — a
444
+ permission probe expects to be refused, and that has to be distinguishable from a dead link. Only
445
+ transport failures throw. Request payloads are never logged (they carry credential digests); the
446
+ host logs the function code and the payload length.
447
+
448
+ Requires an energy manager running **energy-app-sdk 1.9.0 or newer**. On an older host the call
449
+ throws with a message saying so, which is the signal to fall back to monitor-only behaviour rather
450
+ than to retry.
451
+
452
+ ### `onUnitReconnected(unitId, listener)`
453
+
454
+ The permission a login buys belongs to the **socket**, not the device: when the connection is
455
+ replaced it is gone, silently, and the next write simply comes back `0x80`. This is the hook that
456
+ lets a consumer re-authenticate *before* the next command instead of after a failed one.
457
+
458
+ ```ts
459
+ const stop = client.onUnitReconnected(unitId, () => {
460
+ authenticated = false;
461
+ void loginAgain();
462
+ });
463
+ ```
464
+
465
+ Both ways a connection can be replaced are covered — the transport recycling the socket
466
+ underneath (dropped link, half-open socket, stale socket) and this client's own close-and-reopen
467
+ (a poisoned unit, `reconnectUnit()`, `reconnect()`) — and one loss produces **exactly one**
468
+ notification even when both fire. A deliberate `disconnectUnit()` is not a reconnect: connecting
469
+ again afterwards is a new session, and the listener stays quiet.
470
+
471
+ Listeners are registered against the unit, not the socket, so they survive reconnects and keep
472
+ firing. `getConnectionStats().opens` is not a substitute: it counts opens across the whole client,
473
+ not per unit.
474
+
475
+ ---
476
+
419
477
  ## Appliance Metadata the Registers Don't Carry
420
478
 
421
479
  Three appliance fields added in energy-app-sdk 1.6.0 have no SunSpec register behind them, so the SDK cannot derive them — it publishes what the consumer configures, and writes nothing at all when nothing is configured (spreading an explicit `undefined` would erase a value the host set through another path).
@@ -14,7 +14,7 @@ var __exportStar = (this && this.__exportStar) || function(m, exports) {
14
14
  for (var p in m) if (p !== "default" && !Object.prototype.hasOwnProperty.call(exports, p)) __createBinding(exports, m, p);
15
15
  };
16
16
  Object.defineProperty(exports, "__esModule", { value: true });
17
- exports.CalibrationTrigger = exports.CalibrationResultStore = exports.DEFAULT_BATTERY_CALIBRATOR_CONFIG = exports.BatteryCalibrator = exports.AbstractBatteryCalibrationDriver = exports.DEFAULT_AUTO_STOP_MS = exports.SnapshotService = exports.InMemoryCalibrationStorage = exports.AbstractCalibrationStorage = exports.EnyoStorageScheduleDirectionEnum = exports.EnyoStorageScheduleModeEnum = exports.SunspecBatteryScheduleHandler = exports.decodeFeatureResults = exports.SunspecBatteryFeatureCalibrator = exports.SunspecBatteryCalibrationDriver = exports.createSunspecCalibrationStorage = exports.SunspecCalibrationStorage = exports.getSdkVersion = exports.SDK_VERSION = exports.ConnectionRetryManager = void 0;
17
+ exports.CalibrationTrigger = exports.CalibrationResultStore = exports.DEFAULT_BATTERY_CALIBRATOR_CONFIG = exports.BatteryCalibrator = exports.AbstractBatteryCalibrationDriver = exports.DEFAULT_AUTO_STOP_MS = exports.SnapshotService = exports.InMemoryCalibrationStorage = exports.AbstractCalibrationStorage = exports.EnyoStorageScheduleDirectionEnum = exports.EnyoStorageScheduleModeEnum = exports.ModbusExceptionError = exports.MODBUS_MAX_PDU_PAYLOAD_BYTES = exports.SunspecBatteryScheduleHandler = exports.decodeFeatureResults = exports.SunspecBatteryFeatureCalibrator = exports.SunspecBatteryCalibrationDriver = exports.createSunspecCalibrationStorage = exports.SunspecCalibrationStorage = exports.getSdkVersion = exports.SDK_VERSION = exports.ConnectionRetryManager = void 0;
18
18
  __exportStar(require("./sunspec-interfaces.cjs"), exports);
19
19
  __exportStar(require("./sunspec-devices.cjs"), exports);
20
20
  __exportStar(require("./sunspec-modbus-client.cjs"), exports);
@@ -34,6 +34,12 @@ Object.defineProperty(exports, "SunspecBatteryFeatureCalibrator", { enumerable:
34
34
  Object.defineProperty(exports, "decodeFeatureResults", { enumerable: true, get: function () { return sunspec_battery_feature_calibrator_js_1.decodeFeatureResults; } });
35
35
  var sunspec_battery_schedule_handler_js_1 = require("./sunspec-battery-schedule-handler.cjs");
36
36
  Object.defineProperty(exports, "SunspecBatteryScheduleHandler", { enumerable: true, get: function () { return sunspec_battery_schedule_handler_js_1.SunspecBatteryScheduleHandler; } });
37
+ // Re-export the raw-PDU surface so a consumer of `sendRawPdu` / `ModbusExceptionError`
38
+ // needs no second import from energy-app-sdk internals. `ModbusExceptionError` is a
39
+ // class, not a type: an app branches on it with `instanceof`.
40
+ var energy_app_modbus_js_1 = require("@enyo-energy/energy-app-sdk/dist/packages/energy-app-modbus.js");
41
+ Object.defineProperty(exports, "MODBUS_MAX_PDU_PAYLOAD_BYTES", { enumerable: true, get: function () { return energy_app_modbus_js_1.MODBUS_MAX_PDU_PAYLOAD_BYTES; } });
42
+ Object.defineProperty(exports, "ModbusExceptionError", { enumerable: true, get: function () { return energy_app_modbus_js_1.ModbusExceptionError; } });
37
43
  // Re-export the schedule message types from energy-app-sdk so consumers can
38
44
  // build/inspect SetStorageScheduleV1 messages without a second import.
39
45
  var enyo_data_bus_value_js_1 = require("@enyo-energy/energy-app-sdk/dist/types/enyo-data-bus-value.js");
@@ -8,5 +8,6 @@ export { SunspecBatteryCalibrationDriver } from './sunspec-battery-calibration-d
8
8
  export { SunspecBatteryFeatureCalibrator, type SunspecBatteryFeatureCalibratorOptions, decodeFeatureResults, } from './sunspec-battery-feature-calibrator.cjs';
9
9
  export { SunspecBatteryScheduleHandler, type SunspecScheduleRegisters, type SunspecBatteryScheduleHandlerOptions, } from './sunspec-battery-schedule-handler.cjs';
10
10
  export { type EnergyAppModbus, type EnergyAppModbusInstance, type ModbusOptions, } from '@enyo-energy/energy-app-sdk/dist/packages/energy-app-modbus.js';
11
+ export { type ModbusRawPduOptions, type ModbusRawPduResponse, MODBUS_MAX_PDU_PAYLOAD_BYTES, ModbusExceptionError, } from '@enyo-energy/energy-app-sdk/dist/packages/energy-app-modbus.js';
11
12
  export { type EnyoDataBusSetStorageScheduleV1, type EnyoStorageScheduleEntry, EnyoStorageScheduleModeEnum, EnyoStorageScheduleDirectionEnum, } from '@enyo-energy/energy-app-sdk/dist/types/enyo-data-bus-value.js';
12
13
  export { AbstractCalibrationStorage, InMemoryCalibrationStorage, type AckResult, type CalibrationResult, type CalibrationState, type CalibrationSnapshot, type CalibrationRestoreCallback, type RestoreReason, SnapshotService, type SnapshotServiceOptions, DEFAULT_AUTO_STOP_MS, AbstractBatteryCalibrationDriver, BatteryCalibrator, type BatteryCalibratorOptions, type BatteryCalibratorConfig, DEFAULT_BATTERY_CALIBRATOR_CONFIG, CalibrationResultStore, type CalibrationResultStoreData, CalibrationTrigger, type CalibrationTriggerOptions, } from '@enyo-energy/appliance-calibration';
@@ -243,6 +243,17 @@ class SunspecModbusClient {
243
243
  // logging: the first failure of a run is the news, every repeat while the peer stays down is
244
244
  // the same news again. Cleared on the first success for that key.
245
245
  consecutiveConnectFailures = new Map();
246
+ // Listeners registered through onUnitReconnected(), per unit.
247
+ unitReconnectListeners = new Map();
248
+ // Removers for the transport-level reconnect hook, one per open unit. Dropped with the unit.
249
+ unitReconnectUnsubscribers = new Map();
250
+ // Units that have had a live session and have not been deliberately disconnected since. A
251
+ // reopen for a unit in here is a RECYCLE (and therefore a reconnect); the very first open is not.
252
+ unitsWithSession = new Set();
253
+ // Units whose current session has already been reported lost. A dropped socket usually
254
+ // announces itself twice — once by the transport, once by this client's own close/reopen —
255
+ // and an app must not be told to re-authenticate twice for one loss.
256
+ unitSessionReportedLost = new Set();
246
257
  constructor(
247
258
  // The host application. Only used to obtain the default Modbus backend via
248
259
  // `energyApp.useModbus()`. May be omitted (`undefined`) when a `modbusFactory` is supplied.
@@ -401,6 +412,7 @@ class SunspecModbusClient {
401
412
  const units = [...this.modbusInstances.keys()];
402
413
  for (const unitId of units) {
403
414
  await this._closeUnit(unitId);
415
+ this.endUnitSession(unitId);
404
416
  }
405
417
  console.log(`Disconnected from Sunspec device at ${host}:${port} units [${units.join(',')}] (opens=${this.openCount}, closes=${this.closeCount})`);
406
418
  });
@@ -415,6 +427,7 @@ class SunspecModbusClient {
415
427
  const host = this.connectionParams?.primaryHost ?? 'unknown';
416
428
  const port = this.connectionParams?.port ?? 0;
417
429
  await this._closeUnit(unitId);
430
+ this.endUnitSession(unitId);
418
431
  console.log(`Disconnected unit ${unitId} from Sunspec device at ${host}:${port} (opens=${this.openCount}, closes=${this.closeCount})`);
419
432
  });
420
433
  }
@@ -611,9 +624,20 @@ class SunspecModbusClient {
611
624
  if (!candidate) {
612
625
  throw new Error(`useModbus().connect returned null for ${host}:${port} unit ${unitId}`);
613
626
  }
627
+ // Reopening a unit that already had a session is itself a reconnect: whatever the
628
+ // device tracked for the old socket (a vendor login above all) is void. Announce it
629
+ // before the new instance is installed, so a listener re-authenticating on the new
630
+ // session cannot run against the old one.
631
+ if (this.unitsWithSession.has(unitId)) {
632
+ this.notifyUnitReconnected(unitId, 'the unit was reopened');
633
+ }
614
634
  const reader = new EnergyAppModbusFaultTolerantReader_js_1.EnergyAppModbusFaultTolerantReader(candidate, this.connectionHealth);
615
635
  this.modbusInstances.set(unitId, candidate);
616
636
  this.faultTolerantReaders.set(unitId, reader);
637
+ this.watchInstanceReconnects(unitId, candidate);
638
+ // A new session starts clean: it has not been reported lost yet.
639
+ this.unitsWithSession.add(unitId);
640
+ this.unitSessionReportedLost.delete(unitId);
617
641
  // Fresh socket: clear any prior poison and start the freshness clock so a just-opened
618
642
  // unit isn't immediately judged stale.
619
643
  this.poisonedUnits.delete(unitId);
@@ -647,6 +671,10 @@ class SunspecModbusClient {
647
671
  // recovery line reports how long the unit was down.
648
672
  this.poisonedUnits.delete(unitId);
649
673
  this.lastOkAtByUnit.delete(unitId);
674
+ // The transport hook belongs to the instance being dropped. The app's own listeners
675
+ // (unitReconnectListeners) survive — they are registered against the unit, not the socket.
676
+ this.unitReconnectUnsubscribers.get(unitId)?.();
677
+ this.unitReconnectUnsubscribers.delete(unitId);
650
678
  if (instance) {
651
679
  await this.disconnectInstanceBounded(instance, unitId);
652
680
  }
@@ -908,6 +936,126 @@ class SunspecModbusClient {
908
936
  getModbusInstance(unitId) {
909
937
  return this.getInstance(unitId);
910
938
  }
939
+ /**
940
+ * Send one raw Modbus PDU to a unit — a vendor function code the standard Modbus surface
941
+ * cannot express — and return the device's raw answer.
942
+ *
943
+ * This exists for devices that gate control behind a proprietary handshake. The canonical
944
+ * case is a Huawei SUN2000 without an EMMA: every control write is refused with exception
945
+ * 0x80 ("permission authentication failure or permission expiration") until an installer
946
+ * login has been performed over Huawei's function code 0x41, and that permission belongs to
947
+ * the SOCKET — see {@link SunspecModbusClient.onUnitReconnected}.
948
+ *
949
+ * The SDK stays vendor-agnostic: sub-commands, credential digests and keepalives belong to
950
+ * the caller. What the SDK contributes is that the PDU runs inside the unit's existing
951
+ * transaction chain, exactly like {@link SunspecModbusClient.readRegisterBlock} — a login
952
+ * cannot interleave with a block read already in flight, which matters on the single-frame
953
+ * SDongles this client talks to.
954
+ *
955
+ * A device exception comes back as data on {@link ModbusRawPduResponse.exceptionCode}, not
956
+ * as a rejection: a permission probe expects to be refused, and that has to be
957
+ * distinguishable from a dead link. Only transport failures throw.
958
+ *
959
+ * @param unitId Unit whose (already open) connection carries the request.
960
+ * @param functionCode Modbus function code, 1…127.
961
+ * @param payload PDU bytes after the function code; at most 252 bytes.
962
+ * @throws Error if the unit is not open, if the host runtime is too old to support raw PDUs,
963
+ * or if the transport failed.
964
+ */
965
+ async sendRawPdu(unitId, functionCode, payload) {
966
+ const instance = this.getInstance(unitId);
967
+ if (typeof instance.sendRawPdu !== 'function') {
968
+ throw new Error(`Raw Modbus PDUs are not supported by this host runtime — unit ${unitId} needs an energy manager ` +
969
+ `running energy-app-sdk 1.9 or newer`);
970
+ }
971
+ try {
972
+ // Serialized on the unit's chain: a vendor handshake must not cross frames with a poll.
973
+ const response = await this.runExclusive(unitId, () => instance.sendRawPdu(functionCode, payload));
974
+ this.connectionHealth.recordSuccess();
975
+ return response;
976
+ }
977
+ catch (error) {
978
+ this.connectionHealth.recordFailure(error);
979
+ this.logTransactionError(`Error sending raw PDU fc=0x${functionCode.toString(16)} to unit ${unitId}`, error);
980
+ throw error;
981
+ }
982
+ }
983
+ /**
984
+ * Register a listener for "this unit's connection was replaced" — the moment anything the
985
+ * device scoped to the socket, such as a vendor login, became void.
986
+ *
987
+ * Both ways a connection can be replaced are covered: the transport recycling the socket
988
+ * underneath us (a dropped link, a half-open socket, a stale socket), and this client's own
989
+ * close-and-reopen (a poisoned unit, {@link SunspecModbusClient.reconnectUnit},
990
+ * {@link SunspecModbusClient.reconnect}). One loss produces exactly one notification even
991
+ * when both fire. A deliberate {@link SunspecModbusClient.disconnectUnit} ends the session
992
+ * instead — reconnecting afterwards is a new connection, not a recovered one.
993
+ *
994
+ * Listeners are registered against the UNIT, not the socket, so they survive reconnects and
995
+ * keep firing. They must not throw; a throwing listener is logged and ignored.
996
+ *
997
+ * @returns A remover for this listener.
998
+ */
999
+ onUnitReconnected(unitId, listener) {
1000
+ let listeners = this.unitReconnectListeners.get(unitId);
1001
+ if (!listeners) {
1002
+ listeners = new Set();
1003
+ this.unitReconnectListeners.set(unitId, listeners);
1004
+ }
1005
+ listeners.add(listener);
1006
+ return () => {
1007
+ const current = this.unitReconnectListeners.get(unitId);
1008
+ current?.delete(listener);
1009
+ if (current && current.size === 0) {
1010
+ this.unitReconnectListeners.delete(unitId);
1011
+ }
1012
+ };
1013
+ }
1014
+ /**
1015
+ * Subscribe to the transport's own "the socket was replaced" signal for a freshly-opened
1016
+ * unit. Tolerates a host runtime older than energy-app-sdk 1.9, which has no such signal —
1017
+ * there the close-and-reopen path in {@link SunspecModbusClient._openUnitOnce} is the only
1018
+ * notification, which still catches every loss this client itself acts on.
1019
+ */
1020
+ watchInstanceReconnects(unitId, instance) {
1021
+ if (typeof instance.onReconnect !== 'function') {
1022
+ return;
1023
+ }
1024
+ const unsubscribe = instance.onReconnect(() => this.notifyUnitReconnected(unitId, 'the socket was replaced'));
1025
+ this.unitReconnectUnsubscribers.get(unitId)?.();
1026
+ this.unitReconnectUnsubscribers.set(unitId, unsubscribe);
1027
+ }
1028
+ /**
1029
+ * Announce that a unit's connection was replaced — at most once per session, whichever of the
1030
+ * two detection paths gets there first.
1031
+ */
1032
+ notifyUnitReconnected(unitId, reason) {
1033
+ if (this.unitSessionReportedLost.has(unitId)) {
1034
+ return;
1035
+ }
1036
+ this.unitSessionReportedLost.add(unitId);
1037
+ const listeners = this.unitReconnectListeners.get(unitId);
1038
+ if (!listeners || listeners.size === 0) {
1039
+ return;
1040
+ }
1041
+ console.debug(`SunspecModbusClient: unit ${unitId} connection replaced (${reason}); notifying ${listeners.size} listener(s)`);
1042
+ for (const listener of listeners) {
1043
+ try {
1044
+ listener();
1045
+ }
1046
+ catch (error) {
1047
+ console.warn(`SunspecModbusClient: reconnect listener for unit ${unitId} threw: ${error instanceof Error ? error.message : String(error)}`);
1048
+ }
1049
+ }
1050
+ }
1051
+ /**
1052
+ * Forget that a unit ever had a session, so a later open counts as a first connection rather
1053
+ * than a recovery. Called only from the deliberate disconnect paths.
1054
+ */
1055
+ endUnitSession(unitId) {
1056
+ this.unitsWithSession.delete(unitId);
1057
+ this.unitSessionReportedLost.delete(unitId);
1058
+ }
911
1059
  /**
912
1060
  * Get the fault-tolerant reader for a unit, throwing if it isn't open.
913
1061
  */
@@ -18,7 +18,7 @@
18
18
  */
19
19
  import { type SunspecInverterControls, type SunspecInverterData, type SunspecInverterSettings, type SunspecMeterData, type SunspecModel, type SunspecMPPTData, type SunspecBatteryData, type SunspecBatteryBaseData, type SunspecBatteryControls, SunspecStorageMode, type IModbusTransportConfig, type IModbusResilienceConfig } from "./sunspec-interfaces.cjs";
20
20
  import { EnergyAppModbusDataType, IConnectionHealth } from "@enyo-energy/energy-app-sdk/dist/implementations/modbus/interfaces.js";
21
- import { EnergyAppModbus, EnergyAppModbusInstance } from "@enyo-energy/energy-app-sdk/dist/packages/energy-app-modbus.js";
21
+ import { EnergyAppModbus, EnergyAppModbusInstance, ModbusRawPduResponse } from "@enyo-energy/energy-app-sdk/dist/packages/energy-app-modbus.js";
22
22
  import { EnergyApp } from "@enyo-energy/energy-app-sdk";
23
23
  /**
24
24
  * Thrown when a single Modbus transaction (read/write/connect/disconnect) exceeds its configured
@@ -135,6 +135,10 @@ export declare class SunspecModbusClient {
135
135
  private poisonedAtByUnit;
136
136
  private lastOkAtByUnit;
137
137
  private consecutiveConnectFailures;
138
+ private unitReconnectListeners;
139
+ private unitReconnectUnsubscribers;
140
+ private unitsWithSession;
141
+ private unitSessionReportedLost;
138
142
  constructor(energyApp: EnergyApp | undefined, transport?: IModbusTransportConfig, resilience?: IModbusResilienceConfig, modbusFactory?: EnergyAppModbus | undefined);
139
143
  /**
140
144
  * The Modbus backend used to open per-unit connections: the caller-supplied {@link modbusFactory}
@@ -374,6 +378,67 @@ export declare class SunspecModbusClient {
374
378
  * disconnectUnit(unitId) / releaseSunspecClient() as usual.
375
379
  */
376
380
  getModbusInstance(unitId: number): EnergyAppModbusInstance;
381
+ /**
382
+ * Send one raw Modbus PDU to a unit — a vendor function code the standard Modbus surface
383
+ * cannot express — and return the device's raw answer.
384
+ *
385
+ * This exists for devices that gate control behind a proprietary handshake. The canonical
386
+ * case is a Huawei SUN2000 without an EMMA: every control write is refused with exception
387
+ * 0x80 ("permission authentication failure or permission expiration") until an installer
388
+ * login has been performed over Huawei's function code 0x41, and that permission belongs to
389
+ * the SOCKET — see {@link SunspecModbusClient.onUnitReconnected}.
390
+ *
391
+ * The SDK stays vendor-agnostic: sub-commands, credential digests and keepalives belong to
392
+ * the caller. What the SDK contributes is that the PDU runs inside the unit's existing
393
+ * transaction chain, exactly like {@link SunspecModbusClient.readRegisterBlock} — a login
394
+ * cannot interleave with a block read already in flight, which matters on the single-frame
395
+ * SDongles this client talks to.
396
+ *
397
+ * A device exception comes back as data on {@link ModbusRawPduResponse.exceptionCode}, not
398
+ * as a rejection: a permission probe expects to be refused, and that has to be
399
+ * distinguishable from a dead link. Only transport failures throw.
400
+ *
401
+ * @param unitId Unit whose (already open) connection carries the request.
402
+ * @param functionCode Modbus function code, 1…127.
403
+ * @param payload PDU bytes after the function code; at most 252 bytes.
404
+ * @throws Error if the unit is not open, if the host runtime is too old to support raw PDUs,
405
+ * or if the transport failed.
406
+ */
407
+ sendRawPdu(unitId: number, functionCode: number, payload: Buffer): Promise<ModbusRawPduResponse>;
408
+ /**
409
+ * Register a listener for "this unit's connection was replaced" — the moment anything the
410
+ * device scoped to the socket, such as a vendor login, became void.
411
+ *
412
+ * Both ways a connection can be replaced are covered: the transport recycling the socket
413
+ * underneath us (a dropped link, a half-open socket, a stale socket), and this client's own
414
+ * close-and-reopen (a poisoned unit, {@link SunspecModbusClient.reconnectUnit},
415
+ * {@link SunspecModbusClient.reconnect}). One loss produces exactly one notification even
416
+ * when both fire. A deliberate {@link SunspecModbusClient.disconnectUnit} ends the session
417
+ * instead — reconnecting afterwards is a new connection, not a recovered one.
418
+ *
419
+ * Listeners are registered against the UNIT, not the socket, so they survive reconnects and
420
+ * keep firing. They must not throw; a throwing listener is logged and ignored.
421
+ *
422
+ * @returns A remover for this listener.
423
+ */
424
+ onUnitReconnected(unitId: number, listener: () => void): () => void;
425
+ /**
426
+ * Subscribe to the transport's own "the socket was replaced" signal for a freshly-opened
427
+ * unit. Tolerates a host runtime older than energy-app-sdk 1.9, which has no such signal —
428
+ * there the close-and-reopen path in {@link SunspecModbusClient._openUnitOnce} is the only
429
+ * notification, which still catches every loss this client itself acts on.
430
+ */
431
+ private watchInstanceReconnects;
432
+ /**
433
+ * Announce that a unit's connection was replaced — at most once per session, whichever of the
434
+ * two detection paths gets there first.
435
+ */
436
+ private notifyUnitReconnected;
437
+ /**
438
+ * Forget that a unit ever had a session, so a later open counts as a first connection rather
439
+ * than a recovery. Called only from the deliberate disconnect paths.
440
+ */
441
+ private endUnitSession;
377
442
  /**
378
443
  * Get the fault-tolerant reader for a unit, throwing if it isn't open.
379
444
  */
@@ -9,7 +9,7 @@ exports.getSdkVersion = getSdkVersion;
9
9
  /**
10
10
  * Current version of the enyo Energy App SDK.
11
11
  */
12
- exports.SDK_VERSION = '1.0.1';
12
+ exports.SDK_VERSION = '1.1.0';
13
13
  /**
14
14
  * Gets the current SDK version.
15
15
  * @returns The semantic version string of the SDK
@@ -5,7 +5,7 @@
5
5
  /**
6
6
  * Current version of the enyo Energy App SDK.
7
7
  */
8
- export declare const SDK_VERSION = "1.0.1";
8
+ export declare const SDK_VERSION = "1.1.0";
9
9
  /**
10
10
  * Gets the current SDK version.
11
11
  * @returns The semantic version string of the SDK
package/dist/index.d.ts CHANGED
@@ -8,5 +8,6 @@ export { SunspecBatteryCalibrationDriver } from './sunspec-battery-calibration-d
8
8
  export { SunspecBatteryFeatureCalibrator, type SunspecBatteryFeatureCalibratorOptions, decodeFeatureResults, } from './sunspec-battery-feature-calibrator.js';
9
9
  export { SunspecBatteryScheduleHandler, type SunspecScheduleRegisters, type SunspecBatteryScheduleHandlerOptions, } from './sunspec-battery-schedule-handler.js';
10
10
  export { type EnergyAppModbus, type EnergyAppModbusInstance, type ModbusOptions, } from '@enyo-energy/energy-app-sdk/dist/packages/energy-app-modbus.js';
11
+ export { type ModbusRawPduOptions, type ModbusRawPduResponse, MODBUS_MAX_PDU_PAYLOAD_BYTES, ModbusExceptionError, } from '@enyo-energy/energy-app-sdk/dist/packages/energy-app-modbus.js';
11
12
  export { type EnyoDataBusSetStorageScheduleV1, type EnyoStorageScheduleEntry, EnyoStorageScheduleModeEnum, EnyoStorageScheduleDirectionEnum, } from '@enyo-energy/energy-app-sdk/dist/types/enyo-data-bus-value.js';
12
13
  export { AbstractCalibrationStorage, InMemoryCalibrationStorage, type AckResult, type CalibrationResult, type CalibrationState, type CalibrationSnapshot, type CalibrationRestoreCallback, type RestoreReason, SnapshotService, type SnapshotServiceOptions, DEFAULT_AUTO_STOP_MS, AbstractBatteryCalibrationDriver, BatteryCalibrator, type BatteryCalibratorOptions, type BatteryCalibratorConfig, DEFAULT_BATTERY_CALIBRATOR_CONFIG, CalibrationResultStore, type CalibrationResultStoreData, CalibrationTrigger, type CalibrationTriggerOptions, } from '@enyo-energy/appliance-calibration';
package/dist/index.js CHANGED
@@ -8,6 +8,10 @@ export { SunspecCalibrationStorage, createSunspecCalibrationStorage } from './su
8
8
  export { SunspecBatteryCalibrationDriver } from './sunspec-battery-calibration-driver.js';
9
9
  export { SunspecBatteryFeatureCalibrator, decodeFeatureResults, } from './sunspec-battery-feature-calibrator.js';
10
10
  export { SunspecBatteryScheduleHandler, } from './sunspec-battery-schedule-handler.js';
11
+ // Re-export the raw-PDU surface so a consumer of `sendRawPdu` / `ModbusExceptionError`
12
+ // needs no second import from energy-app-sdk internals. `ModbusExceptionError` is a
13
+ // class, not a type: an app branches on it with `instanceof`.
14
+ export { MODBUS_MAX_PDU_PAYLOAD_BYTES, ModbusExceptionError, } from '@enyo-energy/energy-app-sdk/dist/packages/energy-app-modbus.js';
11
15
  // Re-export the schedule message types from energy-app-sdk so consumers can
12
16
  // build/inspect SetStorageScheduleV1 messages without a second import.
13
17
  export { EnyoStorageScheduleModeEnum, EnyoStorageScheduleDirectionEnum, } from '@enyo-energy/energy-app-sdk/dist/types/enyo-data-bus-value.js';
@@ -18,7 +18,7 @@
18
18
  */
19
19
  import { type SunspecInverterControls, type SunspecInverterData, type SunspecInverterSettings, type SunspecMeterData, type SunspecModel, type SunspecMPPTData, type SunspecBatteryData, type SunspecBatteryBaseData, type SunspecBatteryControls, SunspecStorageMode, type IModbusTransportConfig, type IModbusResilienceConfig } from "./sunspec-interfaces.js";
20
20
  import { EnergyAppModbusDataType, IConnectionHealth } from "@enyo-energy/energy-app-sdk/dist/implementations/modbus/interfaces.js";
21
- import { EnergyAppModbus, EnergyAppModbusInstance } from "@enyo-energy/energy-app-sdk/dist/packages/energy-app-modbus.js";
21
+ import { EnergyAppModbus, EnergyAppModbusInstance, ModbusRawPduResponse } from "@enyo-energy/energy-app-sdk/dist/packages/energy-app-modbus.js";
22
22
  import { EnergyApp } from "@enyo-energy/energy-app-sdk";
23
23
  /**
24
24
  * Thrown when a single Modbus transaction (read/write/connect/disconnect) exceeds its configured
@@ -135,6 +135,10 @@ export declare class SunspecModbusClient {
135
135
  private poisonedAtByUnit;
136
136
  private lastOkAtByUnit;
137
137
  private consecutiveConnectFailures;
138
+ private unitReconnectListeners;
139
+ private unitReconnectUnsubscribers;
140
+ private unitsWithSession;
141
+ private unitSessionReportedLost;
138
142
  constructor(energyApp: EnergyApp | undefined, transport?: IModbusTransportConfig, resilience?: IModbusResilienceConfig, modbusFactory?: EnergyAppModbus | undefined);
139
143
  /**
140
144
  * The Modbus backend used to open per-unit connections: the caller-supplied {@link modbusFactory}
@@ -374,6 +378,67 @@ export declare class SunspecModbusClient {
374
378
  * disconnectUnit(unitId) / releaseSunspecClient() as usual.
375
379
  */
376
380
  getModbusInstance(unitId: number): EnergyAppModbusInstance;
381
+ /**
382
+ * Send one raw Modbus PDU to a unit — a vendor function code the standard Modbus surface
383
+ * cannot express — and return the device's raw answer.
384
+ *
385
+ * This exists for devices that gate control behind a proprietary handshake. The canonical
386
+ * case is a Huawei SUN2000 without an EMMA: every control write is refused with exception
387
+ * 0x80 ("permission authentication failure or permission expiration") until an installer
388
+ * login has been performed over Huawei's function code 0x41, and that permission belongs to
389
+ * the SOCKET — see {@link SunspecModbusClient.onUnitReconnected}.
390
+ *
391
+ * The SDK stays vendor-agnostic: sub-commands, credential digests and keepalives belong to
392
+ * the caller. What the SDK contributes is that the PDU runs inside the unit's existing
393
+ * transaction chain, exactly like {@link SunspecModbusClient.readRegisterBlock} — a login
394
+ * cannot interleave with a block read already in flight, which matters on the single-frame
395
+ * SDongles this client talks to.
396
+ *
397
+ * A device exception comes back as data on {@link ModbusRawPduResponse.exceptionCode}, not
398
+ * as a rejection: a permission probe expects to be refused, and that has to be
399
+ * distinguishable from a dead link. Only transport failures throw.
400
+ *
401
+ * @param unitId Unit whose (already open) connection carries the request.
402
+ * @param functionCode Modbus function code, 1…127.
403
+ * @param payload PDU bytes after the function code; at most 252 bytes.
404
+ * @throws Error if the unit is not open, if the host runtime is too old to support raw PDUs,
405
+ * or if the transport failed.
406
+ */
407
+ sendRawPdu(unitId: number, functionCode: number, payload: Buffer): Promise<ModbusRawPduResponse>;
408
+ /**
409
+ * Register a listener for "this unit's connection was replaced" — the moment anything the
410
+ * device scoped to the socket, such as a vendor login, became void.
411
+ *
412
+ * Both ways a connection can be replaced are covered: the transport recycling the socket
413
+ * underneath us (a dropped link, a half-open socket, a stale socket), and this client's own
414
+ * close-and-reopen (a poisoned unit, {@link SunspecModbusClient.reconnectUnit},
415
+ * {@link SunspecModbusClient.reconnect}). One loss produces exactly one notification even
416
+ * when both fire. A deliberate {@link SunspecModbusClient.disconnectUnit} ends the session
417
+ * instead — reconnecting afterwards is a new connection, not a recovered one.
418
+ *
419
+ * Listeners are registered against the UNIT, not the socket, so they survive reconnects and
420
+ * keep firing. They must not throw; a throwing listener is logged and ignored.
421
+ *
422
+ * @returns A remover for this listener.
423
+ */
424
+ onUnitReconnected(unitId: number, listener: () => void): () => void;
425
+ /**
426
+ * Subscribe to the transport's own "the socket was replaced" signal for a freshly-opened
427
+ * unit. Tolerates a host runtime older than energy-app-sdk 1.9, which has no such signal —
428
+ * there the close-and-reopen path in {@link SunspecModbusClient._openUnitOnce} is the only
429
+ * notification, which still catches every loss this client itself acts on.
430
+ */
431
+ private watchInstanceReconnects;
432
+ /**
433
+ * Announce that a unit's connection was replaced — at most once per session, whichever of the
434
+ * two detection paths gets there first.
435
+ */
436
+ private notifyUnitReconnected;
437
+ /**
438
+ * Forget that a unit ever had a session, so a later open counts as a first connection rather
439
+ * than a recovery. Called only from the deliberate disconnect paths.
440
+ */
441
+ private endUnitSession;
377
442
  /**
378
443
  * Get the fault-tolerant reader for a unit, throwing if it isn't open.
379
444
  */
@@ -234,6 +234,17 @@ export class SunspecModbusClient {
234
234
  // logging: the first failure of a run is the news, every repeat while the peer stays down is
235
235
  // the same news again. Cleared on the first success for that key.
236
236
  consecutiveConnectFailures = new Map();
237
+ // Listeners registered through onUnitReconnected(), per unit.
238
+ unitReconnectListeners = new Map();
239
+ // Removers for the transport-level reconnect hook, one per open unit. Dropped with the unit.
240
+ unitReconnectUnsubscribers = new Map();
241
+ // Units that have had a live session and have not been deliberately disconnected since. A
242
+ // reopen for a unit in here is a RECYCLE (and therefore a reconnect); the very first open is not.
243
+ unitsWithSession = new Set();
244
+ // Units whose current session has already been reported lost. A dropped socket usually
245
+ // announces itself twice — once by the transport, once by this client's own close/reopen —
246
+ // and an app must not be told to re-authenticate twice for one loss.
247
+ unitSessionReportedLost = new Set();
237
248
  constructor(
238
249
  // The host application. Only used to obtain the default Modbus backend via
239
250
  // `energyApp.useModbus()`. May be omitted (`undefined`) when a `modbusFactory` is supplied.
@@ -392,6 +403,7 @@ export class SunspecModbusClient {
392
403
  const units = [...this.modbusInstances.keys()];
393
404
  for (const unitId of units) {
394
405
  await this._closeUnit(unitId);
406
+ this.endUnitSession(unitId);
395
407
  }
396
408
  console.log(`Disconnected from Sunspec device at ${host}:${port} units [${units.join(',')}] (opens=${this.openCount}, closes=${this.closeCount})`);
397
409
  });
@@ -406,6 +418,7 @@ export class SunspecModbusClient {
406
418
  const host = this.connectionParams?.primaryHost ?? 'unknown';
407
419
  const port = this.connectionParams?.port ?? 0;
408
420
  await this._closeUnit(unitId);
421
+ this.endUnitSession(unitId);
409
422
  console.log(`Disconnected unit ${unitId} from Sunspec device at ${host}:${port} (opens=${this.openCount}, closes=${this.closeCount})`);
410
423
  });
411
424
  }
@@ -602,9 +615,20 @@ export class SunspecModbusClient {
602
615
  if (!candidate) {
603
616
  throw new Error(`useModbus().connect returned null for ${host}:${port} unit ${unitId}`);
604
617
  }
618
+ // Reopening a unit that already had a session is itself a reconnect: whatever the
619
+ // device tracked for the old socket (a vendor login above all) is void. Announce it
620
+ // before the new instance is installed, so a listener re-authenticating on the new
621
+ // session cannot run against the old one.
622
+ if (this.unitsWithSession.has(unitId)) {
623
+ this.notifyUnitReconnected(unitId, 'the unit was reopened');
624
+ }
605
625
  const reader = new EnergyAppModbusFaultTolerantReader(candidate, this.connectionHealth);
606
626
  this.modbusInstances.set(unitId, candidate);
607
627
  this.faultTolerantReaders.set(unitId, reader);
628
+ this.watchInstanceReconnects(unitId, candidate);
629
+ // A new session starts clean: it has not been reported lost yet.
630
+ this.unitsWithSession.add(unitId);
631
+ this.unitSessionReportedLost.delete(unitId);
608
632
  // Fresh socket: clear any prior poison and start the freshness clock so a just-opened
609
633
  // unit isn't immediately judged stale.
610
634
  this.poisonedUnits.delete(unitId);
@@ -638,6 +662,10 @@ export class SunspecModbusClient {
638
662
  // recovery line reports how long the unit was down.
639
663
  this.poisonedUnits.delete(unitId);
640
664
  this.lastOkAtByUnit.delete(unitId);
665
+ // The transport hook belongs to the instance being dropped. The app's own listeners
666
+ // (unitReconnectListeners) survive — they are registered against the unit, not the socket.
667
+ this.unitReconnectUnsubscribers.get(unitId)?.();
668
+ this.unitReconnectUnsubscribers.delete(unitId);
641
669
  if (instance) {
642
670
  await this.disconnectInstanceBounded(instance, unitId);
643
671
  }
@@ -899,6 +927,126 @@ export class SunspecModbusClient {
899
927
  getModbusInstance(unitId) {
900
928
  return this.getInstance(unitId);
901
929
  }
930
+ /**
931
+ * Send one raw Modbus PDU to a unit — a vendor function code the standard Modbus surface
932
+ * cannot express — and return the device's raw answer.
933
+ *
934
+ * This exists for devices that gate control behind a proprietary handshake. The canonical
935
+ * case is a Huawei SUN2000 without an EMMA: every control write is refused with exception
936
+ * 0x80 ("permission authentication failure or permission expiration") until an installer
937
+ * login has been performed over Huawei's function code 0x41, and that permission belongs to
938
+ * the SOCKET — see {@link SunspecModbusClient.onUnitReconnected}.
939
+ *
940
+ * The SDK stays vendor-agnostic: sub-commands, credential digests and keepalives belong to
941
+ * the caller. What the SDK contributes is that the PDU runs inside the unit's existing
942
+ * transaction chain, exactly like {@link SunspecModbusClient.readRegisterBlock} — a login
943
+ * cannot interleave with a block read already in flight, which matters on the single-frame
944
+ * SDongles this client talks to.
945
+ *
946
+ * A device exception comes back as data on {@link ModbusRawPduResponse.exceptionCode}, not
947
+ * as a rejection: a permission probe expects to be refused, and that has to be
948
+ * distinguishable from a dead link. Only transport failures throw.
949
+ *
950
+ * @param unitId Unit whose (already open) connection carries the request.
951
+ * @param functionCode Modbus function code, 1…127.
952
+ * @param payload PDU bytes after the function code; at most 252 bytes.
953
+ * @throws Error if the unit is not open, if the host runtime is too old to support raw PDUs,
954
+ * or if the transport failed.
955
+ */
956
+ async sendRawPdu(unitId, functionCode, payload) {
957
+ const instance = this.getInstance(unitId);
958
+ if (typeof instance.sendRawPdu !== 'function') {
959
+ throw new Error(`Raw Modbus PDUs are not supported by this host runtime — unit ${unitId} needs an energy manager ` +
960
+ `running energy-app-sdk 1.9 or newer`);
961
+ }
962
+ try {
963
+ // Serialized on the unit's chain: a vendor handshake must not cross frames with a poll.
964
+ const response = await this.runExclusive(unitId, () => instance.sendRawPdu(functionCode, payload));
965
+ this.connectionHealth.recordSuccess();
966
+ return response;
967
+ }
968
+ catch (error) {
969
+ this.connectionHealth.recordFailure(error);
970
+ this.logTransactionError(`Error sending raw PDU fc=0x${functionCode.toString(16)} to unit ${unitId}`, error);
971
+ throw error;
972
+ }
973
+ }
974
+ /**
975
+ * Register a listener for "this unit's connection was replaced" — the moment anything the
976
+ * device scoped to the socket, such as a vendor login, became void.
977
+ *
978
+ * Both ways a connection can be replaced are covered: the transport recycling the socket
979
+ * underneath us (a dropped link, a half-open socket, a stale socket), and this client's own
980
+ * close-and-reopen (a poisoned unit, {@link SunspecModbusClient.reconnectUnit},
981
+ * {@link SunspecModbusClient.reconnect}). One loss produces exactly one notification even
982
+ * when both fire. A deliberate {@link SunspecModbusClient.disconnectUnit} ends the session
983
+ * instead — reconnecting afterwards is a new connection, not a recovered one.
984
+ *
985
+ * Listeners are registered against the UNIT, not the socket, so they survive reconnects and
986
+ * keep firing. They must not throw; a throwing listener is logged and ignored.
987
+ *
988
+ * @returns A remover for this listener.
989
+ */
990
+ onUnitReconnected(unitId, listener) {
991
+ let listeners = this.unitReconnectListeners.get(unitId);
992
+ if (!listeners) {
993
+ listeners = new Set();
994
+ this.unitReconnectListeners.set(unitId, listeners);
995
+ }
996
+ listeners.add(listener);
997
+ return () => {
998
+ const current = this.unitReconnectListeners.get(unitId);
999
+ current?.delete(listener);
1000
+ if (current && current.size === 0) {
1001
+ this.unitReconnectListeners.delete(unitId);
1002
+ }
1003
+ };
1004
+ }
1005
+ /**
1006
+ * Subscribe to the transport's own "the socket was replaced" signal for a freshly-opened
1007
+ * unit. Tolerates a host runtime older than energy-app-sdk 1.9, which has no such signal —
1008
+ * there the close-and-reopen path in {@link SunspecModbusClient._openUnitOnce} is the only
1009
+ * notification, which still catches every loss this client itself acts on.
1010
+ */
1011
+ watchInstanceReconnects(unitId, instance) {
1012
+ if (typeof instance.onReconnect !== 'function') {
1013
+ return;
1014
+ }
1015
+ const unsubscribe = instance.onReconnect(() => this.notifyUnitReconnected(unitId, 'the socket was replaced'));
1016
+ this.unitReconnectUnsubscribers.get(unitId)?.();
1017
+ this.unitReconnectUnsubscribers.set(unitId, unsubscribe);
1018
+ }
1019
+ /**
1020
+ * Announce that a unit's connection was replaced — at most once per session, whichever of the
1021
+ * two detection paths gets there first.
1022
+ */
1023
+ notifyUnitReconnected(unitId, reason) {
1024
+ if (this.unitSessionReportedLost.has(unitId)) {
1025
+ return;
1026
+ }
1027
+ this.unitSessionReportedLost.add(unitId);
1028
+ const listeners = this.unitReconnectListeners.get(unitId);
1029
+ if (!listeners || listeners.size === 0) {
1030
+ return;
1031
+ }
1032
+ console.debug(`SunspecModbusClient: unit ${unitId} connection replaced (${reason}); notifying ${listeners.size} listener(s)`);
1033
+ for (const listener of listeners) {
1034
+ try {
1035
+ listener();
1036
+ }
1037
+ catch (error) {
1038
+ console.warn(`SunspecModbusClient: reconnect listener for unit ${unitId} threw: ${error instanceof Error ? error.message : String(error)}`);
1039
+ }
1040
+ }
1041
+ }
1042
+ /**
1043
+ * Forget that a unit ever had a session, so a later open counts as a first connection rather
1044
+ * than a recovery. Called only from the deliberate disconnect paths.
1045
+ */
1046
+ endUnitSession(unitId) {
1047
+ this.unitsWithSession.delete(unitId);
1048
+ this.unitSessionReportedLost.delete(unitId);
1049
+ }
902
1050
  /**
903
1051
  * Get the fault-tolerant reader for a unit, throwing if it isn't open.
904
1052
  */
package/dist/version.d.ts CHANGED
@@ -5,7 +5,7 @@
5
5
  /**
6
6
  * Current version of the enyo Energy App SDK.
7
7
  */
8
- export declare const SDK_VERSION = "1.0.1";
8
+ export declare const SDK_VERSION = "1.1.0";
9
9
  /**
10
10
  * Gets the current SDK version.
11
11
  * @returns The semantic version string of the SDK
package/dist/version.js CHANGED
@@ -5,7 +5,7 @@
5
5
  /**
6
6
  * Current version of the enyo Energy App SDK.
7
7
  */
8
- export const SDK_VERSION = '1.0.1';
8
+ export const SDK_VERSION = '1.1.0';
9
9
  /**
10
10
  * Gets the current SDK version.
11
11
  * @returns The semantic version string of the SDK
package/package.json CHANGED
@@ -1,6 +1,6 @@
1
1
  {
2
2
  "name": "@enyo-energy/sunspec-sdk",
3
- "version": "1.0.1",
3
+ "version": "1.1.0",
4
4
  "description": "enyo Energy Sunspec SDK",
5
5
  "type": "module",
6
6
  "main": "dist/index.js",
@@ -41,7 +41,7 @@
41
41
  },
42
42
  "dependencies": {
43
43
  "@enyo-energy/appliance-calibration": "0.0.3",
44
- "@enyo-energy/energy-app-sdk": "1.8.0"
44
+ "@enyo-energy/energy-app-sdk": "1.9.0"
45
45
  },
46
46
  "volta": {
47
47
  "node": "22.17.0"