@enyo-energy/sunspec-sdk 0.0.99 → 0.0.101

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
@@ -183,8 +183,26 @@ class BaseSunspecDevice {
183
183
  // device's poll loop detects a dropped connection.
184
184
  const success = await this.sunspecClient.reconnectUnit(this.unitId);
185
185
  if (success) {
186
- // Re-discover models for this unit after reconnect
187
- await this.sunspecClient.discoverModels(this.unitId, this.baseAddress);
186
+ // Re-discover models for this unit after reconnect. discoverModels() clears
187
+ // and repopulates the per-unit model map, so a reconnect that opens the TCP
188
+ // socket but comes back with no usable models (a gateway that accepted the
189
+ // connection before it was ready to answer the SunSpec scan) would leave the
190
+ // map empty. Trusting that would cache an empty map — every read then finds no
191
+ // model while the socket looks healthy, and because reset() disables retry,
192
+ // nothing ever triggers another reconnect. So validate discovery here and, when
193
+ // it's unusable, treat this as a failed reconnect: invalidate the socket so the
194
+ // next poll re-enters tryReconnect(), keep the backoff schedule running, and do
195
+ // NOT reset().
196
+ const models = await this.sunspecClient.discoverModels(this.unitId, this.baseAddress);
197
+ if (!this.isDiscoveryUsable(models)) {
198
+ this.sunspecClient.invalidateUnit(this.unitId, `reconnect discovery found no usable models for unit ${this.unitId}`);
199
+ this.consecutiveReconnectFailures += 1;
200
+ await this.onConnectionFailure(this.consecutiveReconnectFailures);
201
+ console.warn(`${this.constructor.name} ${this.applianceId}: Reconnect attempt #${attempt} ` +
202
+ `opened the socket but discovery returned no usable models ` +
203
+ `(found [${[...models.keys()].join(', ')}]) — retrying with backoff`);
204
+ return false;
205
+ }
188
206
  this.retryManager.reset();
189
207
  this.consecutiveReconnectFailures = 0;
190
208
  // Update appliance state to Connected
@@ -207,6 +225,42 @@ class BaseSunspecDevice {
207
225
  }
208
226
  return false;
209
227
  }
228
+ /**
229
+ * Model IDs this device needs to produce a reading; presence of ANY one means a
230
+ * discovery is usable (one-of semantics — devices expose mutually-exclusive
231
+ * encoding/phase variants, e.g. int+SF vs float, single- vs three-phase). Empty
232
+ * (the base default) means no specific requirement, so any model present
233
+ * suffices. Concrete devices override with their acceptable set — this is the
234
+ * single per-device source of truth reused by both the reconnect discovery gate
235
+ * ({@link isDiscoveryUsable}) and the connect-time presence gate
236
+ * ({@link hasRequiredModels}).
237
+ */
238
+ getRequiredModelIds() {
239
+ return [];
240
+ }
241
+ /**
242
+ * True if the current per-unit discovered-model map satisfies this device's
243
+ * requirement. The connect-time twin of {@link isDiscoveryUsable}: it inspects
244
+ * the already-populated map via findModel() rather than a freshly-returned one.
245
+ * Only meaningful for devices that declare a non-empty required set.
246
+ */
247
+ hasRequiredModels() {
248
+ return this.getRequiredModelIds().some(id => this.sunspecClient.findModel(this.unitId, id) !== undefined);
249
+ }
250
+ /**
251
+ * Decide whether a post-reconnect model discovery is usable. A reconnect that
252
+ * establishes the TCP socket but comes back empty (or with only a Common block)
253
+ * means the device accepted the connection before it was ready to answer the
254
+ * SunSpec scan; the discovered-model map is now missing this device's data
255
+ * model, so trusting the reconnect would leave every read finding no model.
256
+ * Validated generically against {@link getRequiredModelIds}: with a declared
257
+ * set, at least one of those ids must be present; with none declared, fall back
258
+ * to "any model present".
259
+ */
260
+ isDiscoveryUsable(models) {
261
+ const required = this.getRequiredModelIds();
262
+ return required.length === 0 ? models.size > 0 : required.some(id => models.has(id));
263
+ }
210
264
  /**
211
265
  * Hook for subclasses to react to a failed reconnect attempt. Called once
212
266
  * per failed attempt with the running consecutive-failure count.
@@ -364,6 +418,19 @@ class SunspecInverter extends BaseSunspecDevice {
364
418
  pvPowerSource;
365
419
  /** Emit a connection-lost faulted status after this many consecutive failed reconnect attempts. */
366
420
  static CONNECTION_FAULT_THRESHOLD = 3;
421
+ /**
422
+ * The inverter data models this device can read (int+SF 101/103 and IEEE-754
423
+ * float 111/112/113). A post-reconnect discovery that finds none of these has
424
+ * not really recovered the inverter, so {@link isDiscoveryUsable} rejects it —
425
+ * see the override below.
426
+ */
427
+ static INVERTER_MODEL_IDS = [
428
+ sunspec_interfaces_js_1.SunspecModelId.InverterSinglePhase,
429
+ sunspec_interfaces_js_1.SunspecModelId.Inverter3Phase,
430
+ sunspec_interfaces_js_1.SunspecModelId.InverterSinglePhaseFloat,
431
+ sunspec_interfaces_js_1.SunspecModelId.InverterSplitPhaseFloat,
432
+ sunspec_interfaces_js_1.SunspecModelId.Inverter3PhaseFloat
433
+ ];
367
434
  /**
368
435
  * Require this many consecutive operatingState=7 (FAULT) reads before
369
436
  * reporting Faulted. Debounces transient single-poll FAULT reads (e.g. a
@@ -746,6 +813,16 @@ class SunspecInverter extends BaseSunspecDevice {
746
813
  lastStatus: newLastStatus,
747
814
  };
748
815
  }
816
+ /**
817
+ * A reconnect has only recovered the inverter if discovery finds one of its
818
+ * data models. An SE gateway can accept the new socket and answer a partial
819
+ * scan (e.g. only the Common block) before the inverter map is ready — the
820
+ * base size>0 rule would accept that, but every inverter read would then find
821
+ * no 101/103/111/112/113 model and report 0 W. Require an actual inverter model.
822
+ */
823
+ getRequiredModelIds() {
824
+ return SunspecInverter.INVERTER_MODEL_IDS;
825
+ }
749
826
  async onConnectionFailure(consecutiveFailures) {
750
827
  if (!this.applianceId || !this.dataBus)
751
828
  return;
@@ -1295,6 +1372,16 @@ function filterFeaturesByCalibrationResult(detected, result, controllable) {
1295
1372
  class SunspecBattery extends BaseSunspecDevice {
1296
1373
  featureMode;
1297
1374
  capabilities;
1375
+ /**
1376
+ * Battery data models this device can read: Battery (124, full decode) and
1377
+ * BatteryBase (802, derived decode). BatteryControl (803) is intentionally
1378
+ * excluded — it is a decode stub that yields no telemetry — so a rediscovery
1379
+ * that returns only 803 is treated as unrecovered, matching the connect() gate.
1380
+ */
1381
+ static BATTERY_MODEL_IDS = [
1382
+ sunspec_interfaces_js_1.SunspecModelId.Battery,
1383
+ sunspec_interfaces_js_1.SunspecModelId.BatteryBase
1384
+ ];
1298
1385
  snapshotService;
1299
1386
  calibrationDriver;
1300
1387
  batteryCalibrator;
@@ -1398,16 +1485,17 @@ class SunspecBattery extends BaseSunspecDevice {
1398
1485
  getBatteryCalibrator() {
1399
1486
  return this.batteryCalibrator;
1400
1487
  }
1488
+ getRequiredModelIds() {
1489
+ return SunspecBattery.BATTERY_MODEL_IDS;
1490
+ }
1401
1491
  /**
1402
1492
  * Connect to the battery and create/update the appliance
1403
1493
  */
1404
1494
  async connect(inverterApplianceId) {
1405
1495
  // Ensure Sunspec client is connected
1406
1496
  await this.ensureConnected();
1407
- // Check if battery models exist
1408
- const hasBattery = this.sunspecClient.findModel(this.unitId, sunspec_interfaces_js_1.SunspecModelId.Battery) !== undefined ||
1409
- this.sunspecClient.findModel(this.unitId, sunspec_interfaces_js_1.SunspecModelId.BatteryBase) !== undefined;
1410
- if (!hasBattery) {
1497
+ // Check if battery models exist (124 or 802 — see BATTERY_MODEL_IDS).
1498
+ if (!this.hasRequiredModels()) {
1411
1499
  throw new Error('No battery model found in device');
1412
1500
  }
1413
1501
  // Get device info
@@ -1983,6 +2071,20 @@ exports.SunspecBattery = SunspecBattery;
1983
2071
  */
1984
2072
  class SunspecMeter extends BaseSunspecDevice {
1985
2073
  capabilities;
2074
+ /**
2075
+ * Meter data models this device can read, across int+SF (201/203/204) and
2076
+ * IEEE-754 float (211/212/213/214) encodings and single/split/three-phase
2077
+ * variants. Used when the meter is not bound to a specific instance.
2078
+ */
2079
+ static METER_MODEL_IDS = [
2080
+ sunspec_interfaces_js_1.SunspecModelId.MeterSinglePhase,
2081
+ sunspec_interfaces_js_1.SunspecModelId.Meter3Phase,
2082
+ sunspec_interfaces_js_1.SunspecModelId.MeterWye,
2083
+ sunspec_interfaces_js_1.SunspecModelId.MeterSinglePhaseFloat,
2084
+ sunspec_interfaces_js_1.SunspecModelId.MeterSplitPhaseFloat,
2085
+ sunspec_interfaces_js_1.SunspecModelId.Meter3PhaseWyeFloat,
2086
+ sunspec_interfaces_js_1.SunspecModelId.Meter3PhaseDeltaFloat
2087
+ ];
1986
2088
  constructor(energyApp, name, networkDevice, sunspecClient, applianceManager, unitId = 1, port = 502, baseAddress = 40000, capabilities = [], retryConfig, appliance, useTls) {
1987
2089
  super(energyApp, name, networkDevice, sunspecClient, applianceManager, unitId, port, baseAddress, retryConfig, appliance, useTls);
1988
2090
  this.capabilities = capabilities;
@@ -2001,22 +2103,23 @@ class SunspecMeter extends BaseSunspecDevice {
2001
2103
  bindMeterModel(model) {
2002
2104
  this.meterModel = model;
2003
2105
  }
2106
+ /**
2107
+ * A bound meter requires ITS own pinned model id to reappear after a
2108
+ * rediscovery; an unbound meter accepts any meter model on its unit.
2109
+ */
2110
+ getRequiredModelIds() {
2111
+ return this.meterModel ? [this.meterModel.id] : SunspecMeter.METER_MODEL_IDS;
2112
+ }
2004
2113
  /**
2005
2114
  * Connect to the meter and create/update the appliance
2006
2115
  */
2007
2116
  async connect() {
2008
2117
  // Connect with specific unit ID for meter
2009
2118
  await this.ensureConnected();
2010
- // Check if meter models exist (int+SF: 201/203/204, float: 211/212/213/214)
2011
- const hasMeter = this.meterModel !== undefined ||
2012
- this.sunspecClient.findModel(this.unitId, sunspec_interfaces_js_1.SunspecModelId.Meter3Phase) !== undefined ||
2013
- this.sunspecClient.findModel(this.unitId, sunspec_interfaces_js_1.SunspecModelId.MeterWye) !== undefined ||
2014
- this.sunspecClient.findModel(this.unitId, sunspec_interfaces_js_1.SunspecModelId.MeterSinglePhase) !== undefined ||
2015
- this.sunspecClient.findModel(this.unitId, sunspec_interfaces_js_1.SunspecModelId.Meter3PhaseWyeFloat) !== undefined ||
2016
- this.sunspecClient.findModel(this.unitId, sunspec_interfaces_js_1.SunspecModelId.Meter3PhaseDeltaFloat) !== undefined ||
2017
- this.sunspecClient.findModel(this.unitId, sunspec_interfaces_js_1.SunspecModelId.MeterSplitPhaseFloat) !== undefined ||
2018
- this.sunspecClient.findModel(this.unitId, sunspec_interfaces_js_1.SunspecModelId.MeterSinglePhaseFloat) !== undefined;
2019
- if (!hasMeter) {
2119
+ // Check if meter models exist (int+SF: 201/203/204, float: 211/212/213/214).
2120
+ // A bound meter short-circuits: getRequiredModelIds() returns [meterModel.id],
2121
+ // which the just-completed discovery re-listed for the same physical device.
2122
+ if (!this.hasRequiredModels()) {
2020
2123
  throw new Error('No meter model found in device');
2021
2124
  }
2022
2125
  // Get device info. For a bound meter instance, read ITS own Common block (the one
@@ -74,6 +74,35 @@ export declare abstract class BaseSunspecDevice {
74
74
  * Returns true if reconnection succeeded.
75
75
  */
76
76
  protected tryReconnect(): Promise<boolean>;
77
+ /**
78
+ * Model IDs this device needs to produce a reading; presence of ANY one means a
79
+ * discovery is usable (one-of semantics — devices expose mutually-exclusive
80
+ * encoding/phase variants, e.g. int+SF vs float, single- vs three-phase). Empty
81
+ * (the base default) means no specific requirement, so any model present
82
+ * suffices. Concrete devices override with their acceptable set — this is the
83
+ * single per-device source of truth reused by both the reconnect discovery gate
84
+ * ({@link isDiscoveryUsable}) and the connect-time presence gate
85
+ * ({@link hasRequiredModels}).
86
+ */
87
+ protected getRequiredModelIds(): readonly number[];
88
+ /**
89
+ * True if the current per-unit discovered-model map satisfies this device's
90
+ * requirement. The connect-time twin of {@link isDiscoveryUsable}: it inspects
91
+ * the already-populated map via findModel() rather than a freshly-returned one.
92
+ * Only meaningful for devices that declare a non-empty required set.
93
+ */
94
+ protected hasRequiredModels(): boolean;
95
+ /**
96
+ * Decide whether a post-reconnect model discovery is usable. A reconnect that
97
+ * establishes the TCP socket but comes back empty (or with only a Common block)
98
+ * means the device accepted the connection before it was ready to answer the
99
+ * SunSpec scan; the discovered-model map is now missing this device's data
100
+ * model, so trusting the reconnect would leave every read finding no model.
101
+ * Validated generically against {@link getRequiredModelIds}: with a declared
102
+ * set, at least one of those ids must be present; with none declared, fall back
103
+ * to "any model present".
104
+ */
105
+ protected isDiscoveryUsable(models: Map<number, SunspecModel>): boolean;
77
106
  /**
78
107
  * Hook for subclasses to react to a failed reconnect attempt. Called once
79
108
  * per failed attempt with the running consecutive-failure count.
@@ -142,6 +171,13 @@ export declare class SunspecInverter extends BaseSunspecDevice {
142
171
  private readonly pvPowerSource;
143
172
  /** Emit a connection-lost faulted status after this many consecutive failed reconnect attempts. */
144
173
  private static readonly CONNECTION_FAULT_THRESHOLD;
174
+ /**
175
+ * The inverter data models this device can read (int+SF 101/103 and IEEE-754
176
+ * float 111/112/113). A post-reconnect discovery that finds none of these has
177
+ * not really recovered the inverter, so {@link isDiscoveryUsable} rejects it —
178
+ * see the override below.
179
+ */
180
+ private static readonly INVERTER_MODEL_IDS;
145
181
  /**
146
182
  * Require this many consecutive operatingState=7 (FAULT) reads before
147
183
  * reporting Faulted. Debounces transient single-poll FAULT reads (e.g. a
@@ -218,6 +254,14 @@ export declare class SunspecInverter extends BaseSunspecDevice {
218
254
  private hasErrorSetChanged;
219
255
  private buildStatusMessage;
220
256
  private detectAndEmitStatusTransition;
257
+ /**
258
+ * A reconnect has only recovered the inverter if discovery finds one of its
259
+ * data models. An SE gateway can accept the new socket and answer a partial
260
+ * scan (e.g. only the Common block) before the inverter map is ready — the
261
+ * base size>0 rule would accept that, but every inverter read would then find
262
+ * no 101/103/111/112/113 model and report 0 W. Require an actual inverter model.
263
+ */
264
+ protected getRequiredModelIds(): readonly number[];
221
265
  protected onConnectionFailure(consecutiveFailures: number): Promise<void>;
222
266
  protected onConnectionRestored(): Promise<void>;
223
267
  /**
@@ -430,6 +474,13 @@ export declare function filterFeaturesByCalibrationResult(detected: EnyoBatteryF
430
474
  export declare class SunspecBattery extends BaseSunspecDevice {
431
475
  private readonly featureMode;
432
476
  private readonly capabilities;
477
+ /**
478
+ * Battery data models this device can read: Battery (124, full decode) and
479
+ * BatteryBase (802, derived decode). BatteryControl (803) is intentionally
480
+ * excluded — it is a decode stub that yields no telemetry — so a rediscovery
481
+ * that returns only 803 is treated as unrecovered, matching the connect() gate.
482
+ */
483
+ private static readonly BATTERY_MODEL_IDS;
433
484
  private snapshotService?;
434
485
  private calibrationDriver?;
435
486
  private batteryCalibrator?;
@@ -478,6 +529,7 @@ export declare class SunspecBattery extends BaseSunspecDevice {
478
529
  * `CalibrationTrigger`.
479
530
  */
480
531
  getBatteryCalibrator(): BatteryCalibrator<SunspecBatteryControls> | undefined;
532
+ protected getRequiredModelIds(): readonly number[];
481
533
  /**
482
534
  * Connect to the battery and create/update the appliance
483
535
  */
@@ -646,6 +698,12 @@ export declare class SunspecBattery extends BaseSunspecDevice {
646
698
  */
647
699
  export declare class SunspecMeter extends BaseSunspecDevice {
648
700
  private readonly capabilities;
701
+ /**
702
+ * Meter data models this device can read, across int+SF (201/203/204) and
703
+ * IEEE-754 float (211/212/213/214) encodings and single/split/three-phase
704
+ * variants. Used when the meter is not bound to a specific instance.
705
+ */
706
+ private static readonly METER_MODEL_IDS;
649
707
  constructor(energyApp: EnergyApp, name: EnyoApplianceName[], networkDevice: EnyoNetworkDevice, sunspecClient: SunspecModbusClient, applianceManager: ApplianceManager, unitId?: number, port?: number, baseAddress?: number, capabilities?: SunspecMeterCapability[], retryConfig?: IRetryConfig, appliance?: EnyoAppliance, useTls?: boolean);
650
708
  /**
651
709
  * The specific meter model instance this meter reads, when its unit hosts more than one
@@ -659,6 +717,11 @@ export declare class SunspecMeter extends BaseSunspecDevice {
659
717
  * {@link SunspecModbusClient.findModels}). Call before {@link connect}.
660
718
  */
661
719
  bindMeterModel(model: SunspecModel): void;
720
+ /**
721
+ * A bound meter requires ITS own pinned model id to reappear after a
722
+ * rediscovery; an unbound meter accepts any meter model on its unit.
723
+ */
724
+ protected getRequiredModelIds(): readonly number[];
662
725
  /**
663
726
  * Connect to the meter and create/update the appliance
664
727
  */
@@ -20,6 +20,8 @@ exports.DEFAULT_MODBUS_RESILIENCE_CONFIG = {
20
20
  connectTimeoutMs: 5_000,
21
21
  disconnectTimeoutMs: 5_000,
22
22
  staleSocketMs: 30_000,
23
+ connectRetries: 1,
24
+ connectRetryDelayMs: 500,
23
25
  };
24
26
  /**
25
27
  * Common Sunspec Model IDs
@@ -82,6 +82,20 @@ export interface IModbusResilienceConfig {
82
82
  * Set 0 to disable staleness detection.
83
83
  */
84
84
  staleSocketMs?: number;
85
+ /**
86
+ * Number of extra attempts to retry the initial per-unit TCP connect after the first one fails,
87
+ * before giving up and throwing. A transient gateway hiccup at (re)connect time — e.g. a
88
+ * SolarEdge gateway still waking up in the seconds right after an app restart — would otherwise
89
+ * fail the whole unit for a full reconnect cycle and cascade into a long telemetry gap. Each
90
+ * attempt is independently bounded by {@link connectTimeoutMs}. Default 1 (2 attempts total).
91
+ * Set 0 to preserve the old fail-fast behaviour.
92
+ */
93
+ connectRetries?: number;
94
+ /**
95
+ * Fixed backoff between consecutive connect attempts, in ms. Only applies when
96
+ * {@link connectRetries} > 0. Default 500.
97
+ */
98
+ connectRetryDelayMs?: number;
85
99
  }
86
100
  export declare const DEFAULT_MODBUS_RESILIENCE_CONFIG: Required<IModbusResilienceConfig>;
87
101
  /**
@@ -3,6 +3,7 @@ Object.defineProperty(exports, "__esModule", { value: true });
3
3
  exports.SunspecModbusClient = exports.ModbusOperationTimeoutError = void 0;
4
4
  exports.getOrCreateSunspecClient = getOrCreateSunspecClient;
5
5
  exports.releaseSunspecClient = releaseSunspecClient;
6
+ exports.retryAsync = retryAsync;
6
7
  /**
7
8
  * Sunspec Modbus Client Implementation
8
9
  *
@@ -98,6 +99,31 @@ async function releaseSunspecClient(host, port = 502) {
98
99
  }
99
100
  }
100
101
  }
102
+ /**
103
+ * Retry an async operation a bounded number of times with a fixed backoff between attempts,
104
+ * rethrowing the last error if every attempt fails. Used to make the initial per-unit connect
105
+ * resilient to a transient gateway hiccup at (re)connect time — the failure mode where a single
106
+ * connect timeout at launch would otherwise cascade into a long outage for the whole device.
107
+ * `sleep` is injectable so tests don't incur real delay; `onRetry` reports each retried failure.
108
+ */
109
+ async function retryAsync(fn, opts) {
110
+ const attempts = Math.max(1, opts.attempts);
111
+ const sleep = opts.sleep ?? ((ms) => new Promise(resolve => setTimeout(resolve, ms)));
112
+ let lastError;
113
+ for (let attempt = 1; attempt <= attempts; attempt++) {
114
+ try {
115
+ return await fn(attempt);
116
+ }
117
+ catch (error) {
118
+ lastError = error;
119
+ if (attempt < attempts) {
120
+ opts.onRetry?.(error, attempt);
121
+ await sleep(opts.delayMs);
122
+ }
123
+ }
124
+ }
125
+ throw lastError;
126
+ }
101
127
  class SunspecModbusClient {
102
128
  energyApp;
103
129
  pacing;
@@ -175,42 +201,7 @@ class SunspecModbusClient {
175
201
  */
176
202
  async connect(host, port = 502, unitId = 1, secondaryHost, useTls, tls) {
177
203
  return this.withConnectionLock(async () => {
178
- if (this.connectionParams) {
179
- if (this.connectionParams.primaryHost !== host || this.connectionParams.port !== port) {
180
- throw new Error(`SunspecModbusClient is bound to ${this.connectionParams.primaryHost}:${this.connectionParams.port}; ` +
181
- `cannot reuse it for ${host}:${port}. Use getOrCreateSunspecClient() per (host, port).`);
182
- }
183
- if (secondaryHost && !this.connectionParams.secondaryHost) {
184
- this.connectionParams.secondaryHost = secondaryHost;
185
- }
186
- if (useTls !== undefined) {
187
- this.connectionParams.useTls = useTls;
188
- }
189
- if (tls?.cert !== undefined) {
190
- this.connectionParams.cert = tls.cert;
191
- }
192
- if (tls?.key !== undefined) {
193
- this.connectionParams.key = tls.key;
194
- }
195
- if (tls?.ca !== undefined) {
196
- this.connectionParams.ca = tls.ca;
197
- }
198
- if (tls?.rejectUnauthorized !== undefined) {
199
- this.connectionParams.rejectUnauthorized = tls.rejectUnauthorized;
200
- }
201
- }
202
- else {
203
- this.connectionParams = {
204
- primaryHost: host,
205
- secondaryHost,
206
- port,
207
- useTls,
208
- cert: tls?.cert,
209
- key: tls?.key,
210
- ca: tls?.ca,
211
- rejectUnauthorized: tls?.rejectUnauthorized,
212
- };
213
- }
204
+ this.reconcileConnectionParams(host, port, secondaryHost, useTls, tls);
214
205
  this.knownUnits.add(unitId);
215
206
  if (this.modbusInstances.has(unitId)) {
216
207
  console.debug(`connect(): unit ${unitId} on ${host}:${port} already open, skipping`);
@@ -220,6 +211,74 @@ class SunspecModbusClient {
220
211
  console.log(`Connected to Sunspec device at ${host}:${port} unit ${unitId} (opens=${this.openCount}, closes=${this.closeCount}, openUnits=${this.modbusInstances.size})`);
221
212
  });
222
213
  }
214
+ /**
215
+ * Fast-fail probe of a unit for speculative RS485-chain scans, where most candidate unit IDs
216
+ * are absent. On success the unit is opened and kept exactly as {@link connect} would; the
217
+ * difference is the FAILURE path: a probe does NOT retry the connect (unlike connect(), which
218
+ * honours {@link IModbusResilienceConfig.connectRetries}) and uses a caller-supplied, typically
219
+ * shorter, connect timeout. So scanning a range of mostly-dead units costs ~`timeoutMs` each
220
+ * instead of the full retrying connect budget — the reason a warm reconnect must never queue
221
+ * its meter/battery attach behind such a scan. Throws on failure; nothing is left open.
222
+ */
223
+ async probeUnit(host, port = 502, unitId = 1, opts = {}) {
224
+ return this.withConnectionLock(async () => {
225
+ this.reconcileConnectionParams(host, port, opts.secondaryHost);
226
+ this.knownUnits.add(unitId);
227
+ if (this.modbusInstances.has(unitId)) {
228
+ console.debug(`probeUnit(): unit ${unitId} on ${host}:${port} already open, skipping`);
229
+ return;
230
+ }
231
+ await this._openUnit(host, port, unitId, {
232
+ connectRetries: 0,
233
+ connectTimeoutMs: opts.timeoutMs ?? this.resilience.connectTimeoutMs,
234
+ });
235
+ console.log(`Probed Sunspec unit ${unitId} at ${host}:${port} — open (opens=${this.openCount}, closes=${this.closeCount}, openUnits=${this.modbusInstances.size})`);
236
+ });
237
+ }
238
+ /**
239
+ * Reconcile/lock in this client's connection parameters. The first call binds the client to a
240
+ * single (host, port); later calls for a different endpoint throw (use one client per endpoint
241
+ * via {@link getOrCreateSunspecClient}). Optional secondaryHost/TLS material fills in on first
242
+ * sight without clobbering. Caller must hold the connection lock.
243
+ */
244
+ reconcileConnectionParams(host, port, secondaryHost, useTls, tls) {
245
+ if (this.connectionParams) {
246
+ if (this.connectionParams.primaryHost !== host || this.connectionParams.port !== port) {
247
+ throw new Error(`SunspecModbusClient is bound to ${this.connectionParams.primaryHost}:${this.connectionParams.port}; ` +
248
+ `cannot reuse it for ${host}:${port}. Use getOrCreateSunspecClient() per (host, port).`);
249
+ }
250
+ if (secondaryHost && !this.connectionParams.secondaryHost) {
251
+ this.connectionParams.secondaryHost = secondaryHost;
252
+ }
253
+ if (useTls !== undefined) {
254
+ this.connectionParams.useTls = useTls;
255
+ }
256
+ if (tls?.cert !== undefined) {
257
+ this.connectionParams.cert = tls.cert;
258
+ }
259
+ if (tls?.key !== undefined) {
260
+ this.connectionParams.key = tls.key;
261
+ }
262
+ if (tls?.ca !== undefined) {
263
+ this.connectionParams.ca = tls.ca;
264
+ }
265
+ if (tls?.rejectUnauthorized !== undefined) {
266
+ this.connectionParams.rejectUnauthorized = tls.rejectUnauthorized;
267
+ }
268
+ }
269
+ else {
270
+ this.connectionParams = {
271
+ primaryHost: host,
272
+ secondaryHost,
273
+ port,
274
+ useTls,
275
+ cert: tls?.cert,
276
+ key: tls?.key,
277
+ ca: tls?.ca,
278
+ rejectUnauthorized: tls?.rejectUnauthorized,
279
+ };
280
+ }
281
+ }
223
282
  /**
224
283
  * Disconnect from all units of this network device.
225
284
  *
@@ -344,21 +403,42 @@ class SunspecModbusClient {
344
403
  }
345
404
  }
346
405
  /**
347
- * Open a new Modbus instance for one unit ID and wire up its fault-tolerant reader.
348
- * On any failure, the just-opened instance (if any) is closed so we never leak. Caller must
349
- * hold the connection lock and ensure the unit is not already open.
406
+ * Open a unit, retrying the connect on a transient failure per the resilience config
407
+ * ({@link IModbusResilienceConfig.connectRetries}). Each attempt is a full {@link _openUnitOnce}
408
+ * — which independently bounds its connect at {@link IModbusResilienceConfig.connectTimeoutMs}
409
+ * and tears down any half-open candidate before rethrowing — so retries never leak a socket.
410
+ *
411
+ * `override` lets a caller tune this single open: {@link probeUnit} passes `connectRetries: 0`
412
+ * and a shorter `connectTimeoutMs` to fast-fail a speculative scan; omitted fields fall back to
413
+ * the client's resilience config.
414
+ */
415
+ async _openUnit(host, port, unitId, override) {
416
+ const connectTimeoutMs = override?.connectTimeoutMs ?? this.resilience.connectTimeoutMs;
417
+ const attempts = (override?.connectRetries ?? this.resilience.connectRetries) + 1;
418
+ await retryAsync(() => this._openUnitOnce(host, port, unitId, connectTimeoutMs), {
419
+ attempts,
420
+ delayMs: this.resilience.connectRetryDelayMs,
421
+ onRetry: (error, attempt) => console.warn(`SunspecModbusClient: connect to ${host}:${port} unit ${unitId} failed ` +
422
+ `(attempt ${attempt}/${attempts}): ${error instanceof Error ? error.message : String(error)}; ` +
423
+ `retrying in ${this.resilience.connectRetryDelayMs}ms`),
424
+ });
425
+ }
426
+ /**
427
+ * Open a new Modbus instance for one unit ID and wire up its fault-tolerant reader. Bounds the
428
+ * connect at `connectTimeoutMs`. On any failure, the just-opened instance (if any) is closed so
429
+ * we never leak. Caller must hold the connection lock and ensure the unit is not already open.
350
430
  */
351
- async _openUnit(host, port, unitId) {
431
+ async _openUnitOnce(host, port, unitId, connectTimeoutMs = this.resilience.connectTimeoutMs) {
352
432
  let candidate = null;
353
433
  try {
354
434
  // Enforce the connect budget ourselves in addition to forwarding it as the transport's
355
435
  // `timeout`: the transport applies it to the TCP handshake, but a sleeping/half-open peer
356
436
  // can still leave the returned promise pending — bound it independently.
357
- candidate = await this.withTimeout('connect', unitId, this.resilience.connectTimeoutMs, () => this.energyApp.useModbus().connect({
437
+ candidate = await this.withTimeout('connect', unitId, connectTimeoutMs, () => this.energyApp.useModbus().connect({
358
438
  host,
359
439
  port,
360
440
  unitId,
361
- timeout: this.resilience.connectTimeoutMs,
441
+ timeout: connectTimeoutMs,
362
442
  useTls: this.connectionParams?.useTls,
363
443
  cert: this.connectionParams?.cert,
364
444
  key: this.connectionParams?.key,
@@ -501,6 +581,25 @@ class SunspecModbusClient {
501
581
  this.poisonedUnits.add(unitId);
502
582
  this.connectionHealth.recordFailure(error);
503
583
  }
584
+ /**
585
+ * Publicly invalidate a unit's socket so {@link isHealthy} returns false and the next
586
+ * readData()/tryReconnect() cycle recycles it — the same effect as a timeout poison but
587
+ * for a caller-detected fault that isn't itself a Modbus timeout.
588
+ *
589
+ * The motivating case: a TCP reconnect succeeds but the follow-up model discovery comes
590
+ * back empty because the gateway (e.g. a SolarEdge unit) accepted the socket before it was
591
+ * ready to answer the SunSpec scan. The link looks alive, so without this the reconnect
592
+ * would be trusted, an empty model map cached, and every subsequent read would find no
593
+ * model while nothing ever triggers another reconnect. Poisoning here keeps the retry
594
+ * schedule firing until a real discovery lands. Idempotent; only logs on the first call.
595
+ */
596
+ invalidateUnit(unitId, reason) {
597
+ if (!this.poisonedUnits.has(unitId)) {
598
+ console.warn(`SunspecModbusClient: invalidating unit ${unitId} socket — ${reason}; reconnect path will recycle it`);
599
+ }
600
+ this.poisonedUnits.add(unitId);
601
+ this.connectionHealth.recordFailure(new Error(reason));
602
+ }
504
603
  /**
505
604
  * A unit's socket is stale when the transport still reports it connected but no successful
506
605
  * transaction has completed within staleSocketMs — the signature of a half-open link where