@enyo-energy/sunspec-sdk 0.0.98 → 0.0.100

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
@@ -16,10 +16,26 @@
16
16
  * - pad: 0x8000 (always returns this value)
17
17
  * - string: all registers 0x0000 (NULL)
18
18
  */
19
- import { SunspecModelId, SunspecBatteryChargeState, SunspecStorageControlMode, SunspecChargeSource, SunspecEnableControl, SunspecStorageMode, SunspecBatteryType, SunspecBatteryBankState, } from "./sunspec-interfaces.js";
19
+ import { SunspecModelId, SunspecBatteryChargeState, SunspecStorageControlMode, SunspecChargeSource, SunspecEnableControl, SunspecStorageMode, SunspecBatteryType, SunspecBatteryBankState, DEFAULT_MODBUS_RESILIENCE_CONFIG, } from "./sunspec-interfaces.js";
20
20
  import { EnergyAppModbusConnectionHealth } from "@enyo-energy/energy-app-sdk/dist/implementations/modbus/EnergyAppModbusConnectionHealth.js";
21
21
  import { EnergyAppModbusFaultTolerantReader } from "@enyo-energy/energy-app-sdk/dist/implementations/modbus/EnergyAppModbusFaultTolerantReader.js";
22
22
  import { EnergyAppModbusDataTypeConverter } from "@enyo-energy/energy-app-sdk/dist/implementations/modbus/EnergyAppModbusDataTypeConverter.js";
23
+ /**
24
+ * Thrown when a single Modbus transaction (read/write/connect/disconnect) exceeds its configured
25
+ * time budget. Surfaced instead of letting a half-open socket leave the operation pending forever.
26
+ */
27
+ export class ModbusOperationTimeoutError extends Error {
28
+ operation;
29
+ unitId;
30
+ timeoutMs;
31
+ constructor(operation, unitId, timeoutMs) {
32
+ super(`Modbus ${operation} on unit ${unitId} timed out after ${timeoutMs}ms`);
33
+ this.operation = operation;
34
+ this.unitId = unitId;
35
+ this.timeoutMs = timeoutMs;
36
+ this.name = 'ModbusOperationTimeoutError';
37
+ }
38
+ }
23
39
  /**
24
40
  * Module-level registry: one SunspecModbusClient per network device (host:port).
25
41
  * Refcounted so the underlying connection only tears down when the last consumer releases.
@@ -30,15 +46,15 @@ const registryKey = (host, port) => `${host}:${port}`;
30
46
  * Get (or create) the singleton SunspecModbusClient for this network device.
31
47
  * Increments the refcount; pair with `releaseSunspecClient` on teardown.
32
48
  *
33
- * NOTE: `pacing` is only applied when the client is FIRST created for a given host:port.
34
- * Because the client is cached and refcounted, a later caller passing a different `pacing`
49
+ * NOTE: `pacing` and `resilience` are only applied when the client is FIRST created for a given
50
+ * host:port. Because the client is cached and refcounted, a later caller passing different config
35
51
  * receives the already-created instance and its config is ignored.
36
52
  */
37
- export function getOrCreateSunspecClient(energyApp, host, port = 502, pacing) {
53
+ export function getOrCreateSunspecClient(energyApp, host, port = 502, pacing, resilience) {
38
54
  const key = registryKey(host, port);
39
55
  let entry = CLIENT_REGISTRY.get(key);
40
56
  if (!entry) {
41
- entry = { client: new SunspecModbusClient(energyApp, pacing), refcount: 0 };
57
+ entry = { client: new SunspecModbusClient(energyApp, pacing, resilience), refcount: 0 };
42
58
  CLIENT_REGISTRY.set(key, entry);
43
59
  }
44
60
  entry.refcount++;
@@ -76,6 +92,31 @@ export async function releaseSunspecClient(host, port = 502) {
76
92
  }
77
93
  }
78
94
  }
95
+ /**
96
+ * Retry an async operation a bounded number of times with a fixed backoff between attempts,
97
+ * rethrowing the last error if every attempt fails. Used to make the initial per-unit connect
98
+ * resilient to a transient gateway hiccup at (re)connect time — the failure mode where a single
99
+ * connect timeout at launch would otherwise cascade into a long outage for the whole device.
100
+ * `sleep` is injectable so tests don't incur real delay; `onRetry` reports each retried failure.
101
+ */
102
+ export async function retryAsync(fn, opts) {
103
+ const attempts = Math.max(1, opts.attempts);
104
+ const sleep = opts.sleep ?? ((ms) => new Promise(resolve => setTimeout(resolve, ms)));
105
+ let lastError;
106
+ for (let attempt = 1; attempt <= attempts; attempt++) {
107
+ try {
108
+ return await fn(attempt);
109
+ }
110
+ catch (error) {
111
+ lastError = error;
112
+ if (attempt < attempts) {
113
+ opts.onRetry?.(error, attempt);
114
+ await sleep(opts.delayMs);
115
+ }
116
+ }
117
+ }
118
+ throw lastError;
119
+ }
79
120
  export class SunspecModbusClient {
80
121
  energyApp;
81
122
  pacing;
@@ -111,15 +152,30 @@ export class SunspecModbusClient {
111
152
  // operationChain (the connection lock) to avoid re-entrancy: a transaction never waits
112
153
  // on a connect/disconnect, and vice versa.
113
154
  txChains = new Map();
155
+ // Effective resilience config (per-op timeouts + staleness window), merged with defaults.
156
+ resilience;
157
+ // Units whose last transaction timed out. A timed-out Promise.race abandons the in-flight
158
+ // request but cannot cancel it — the response may still land later and desync the next
159
+ // transaction's framing. So a poisoned unit refuses further I/O until reconnectUnit() tears
160
+ // the socket down and reopens it (which clears the flag).
161
+ poisonedUnits = new Set();
162
+ // Wall-clock of each unit's last SUCCESSFUL transaction. Drives half-open detection: a socket
163
+ // the transport still reports connected but that has gone quiet past staleSocketMs is presumed
164
+ // dead. Absent entry = no successful op yet (never treated as stale — give it a chance).
165
+ lastOkAtByUnit = new Map();
114
166
  constructor(energyApp,
115
167
  // Opt-in pacing (default off). Passed straight through to `useModbus().connect()`, which
116
168
  // serializes frames (`noParallelRequests`) and spaces them (`waitBetweenMessagesMs`) on the
117
169
  // connection. An empty object leaves both undefined so the SDK applies its own defaults.
118
- pacing = {}) {
170
+ pacing = {},
171
+ // Per-operation timeouts + half-open detection. Merged with DEFAULT_MODBUS_RESILIENCE_CONFIG
172
+ // so omitted fields keep their defaults.
173
+ resilience = {}) {
119
174
  this.energyApp = energyApp;
120
175
  this.pacing = pacing;
121
176
  this.connectionHealth = new EnergyAppModbusConnectionHealth();
122
177
  this.modbusDataTypeConverter = new EnergyAppModbusDataTypeConverter();
178
+ this.resilience = { ...DEFAULT_MODBUS_RESILIENCE_CONFIG, ...resilience };
123
179
  }
124
180
  /**
125
181
  * Connect to a Modbus device unit. Multiple unit IDs on the same network device share this
@@ -138,42 +194,7 @@ export class SunspecModbusClient {
138
194
  */
139
195
  async connect(host, port = 502, unitId = 1, secondaryHost, useTls, tls) {
140
196
  return this.withConnectionLock(async () => {
141
- if (this.connectionParams) {
142
- if (this.connectionParams.primaryHost !== host || this.connectionParams.port !== port) {
143
- throw new Error(`SunspecModbusClient is bound to ${this.connectionParams.primaryHost}:${this.connectionParams.port}; ` +
144
- `cannot reuse it for ${host}:${port}. Use getOrCreateSunspecClient() per (host, port).`);
145
- }
146
- if (secondaryHost && !this.connectionParams.secondaryHost) {
147
- this.connectionParams.secondaryHost = secondaryHost;
148
- }
149
- if (useTls !== undefined) {
150
- this.connectionParams.useTls = useTls;
151
- }
152
- if (tls?.cert !== undefined) {
153
- this.connectionParams.cert = tls.cert;
154
- }
155
- if (tls?.key !== undefined) {
156
- this.connectionParams.key = tls.key;
157
- }
158
- if (tls?.ca !== undefined) {
159
- this.connectionParams.ca = tls.ca;
160
- }
161
- if (tls?.rejectUnauthorized !== undefined) {
162
- this.connectionParams.rejectUnauthorized = tls.rejectUnauthorized;
163
- }
164
- }
165
- else {
166
- this.connectionParams = {
167
- primaryHost: host,
168
- secondaryHost,
169
- port,
170
- useTls,
171
- cert: tls?.cert,
172
- key: tls?.key,
173
- ca: tls?.ca,
174
- rejectUnauthorized: tls?.rejectUnauthorized,
175
- };
176
- }
197
+ this.reconcileConnectionParams(host, port, secondaryHost, useTls, tls);
177
198
  this.knownUnits.add(unitId);
178
199
  if (this.modbusInstances.has(unitId)) {
179
200
  console.debug(`connect(): unit ${unitId} on ${host}:${port} already open, skipping`);
@@ -183,6 +204,74 @@ export class SunspecModbusClient {
183
204
  console.log(`Connected to Sunspec device at ${host}:${port} unit ${unitId} (opens=${this.openCount}, closes=${this.closeCount}, openUnits=${this.modbusInstances.size})`);
184
205
  });
185
206
  }
207
+ /**
208
+ * Fast-fail probe of a unit for speculative RS485-chain scans, where most candidate unit IDs
209
+ * are absent. On success the unit is opened and kept exactly as {@link connect} would; the
210
+ * difference is the FAILURE path: a probe does NOT retry the connect (unlike connect(), which
211
+ * honours {@link IModbusResilienceConfig.connectRetries}) and uses a caller-supplied, typically
212
+ * shorter, connect timeout. So scanning a range of mostly-dead units costs ~`timeoutMs` each
213
+ * instead of the full retrying connect budget — the reason a warm reconnect must never queue
214
+ * its meter/battery attach behind such a scan. Throws on failure; nothing is left open.
215
+ */
216
+ async probeUnit(host, port = 502, unitId = 1, opts = {}) {
217
+ return this.withConnectionLock(async () => {
218
+ this.reconcileConnectionParams(host, port, opts.secondaryHost);
219
+ this.knownUnits.add(unitId);
220
+ if (this.modbusInstances.has(unitId)) {
221
+ console.debug(`probeUnit(): unit ${unitId} on ${host}:${port} already open, skipping`);
222
+ return;
223
+ }
224
+ await this._openUnit(host, port, unitId, {
225
+ connectRetries: 0,
226
+ connectTimeoutMs: opts.timeoutMs ?? this.resilience.connectTimeoutMs,
227
+ });
228
+ console.log(`Probed Sunspec unit ${unitId} at ${host}:${port} — open (opens=${this.openCount}, closes=${this.closeCount}, openUnits=${this.modbusInstances.size})`);
229
+ });
230
+ }
231
+ /**
232
+ * Reconcile/lock in this client's connection parameters. The first call binds the client to a
233
+ * single (host, port); later calls for a different endpoint throw (use one client per endpoint
234
+ * via {@link getOrCreateSunspecClient}). Optional secondaryHost/TLS material fills in on first
235
+ * sight without clobbering. Caller must hold the connection lock.
236
+ */
237
+ reconcileConnectionParams(host, port, secondaryHost, useTls, tls) {
238
+ if (this.connectionParams) {
239
+ if (this.connectionParams.primaryHost !== host || this.connectionParams.port !== port) {
240
+ throw new Error(`SunspecModbusClient is bound to ${this.connectionParams.primaryHost}:${this.connectionParams.port}; ` +
241
+ `cannot reuse it for ${host}:${port}. Use getOrCreateSunspecClient() per (host, port).`);
242
+ }
243
+ if (secondaryHost && !this.connectionParams.secondaryHost) {
244
+ this.connectionParams.secondaryHost = secondaryHost;
245
+ }
246
+ if (useTls !== undefined) {
247
+ this.connectionParams.useTls = useTls;
248
+ }
249
+ if (tls?.cert !== undefined) {
250
+ this.connectionParams.cert = tls.cert;
251
+ }
252
+ if (tls?.key !== undefined) {
253
+ this.connectionParams.key = tls.key;
254
+ }
255
+ if (tls?.ca !== undefined) {
256
+ this.connectionParams.ca = tls.ca;
257
+ }
258
+ if (tls?.rejectUnauthorized !== undefined) {
259
+ this.connectionParams.rejectUnauthorized = tls.rejectUnauthorized;
260
+ }
261
+ }
262
+ else {
263
+ this.connectionParams = {
264
+ primaryHost: host,
265
+ secondaryHost,
266
+ port,
267
+ useTls,
268
+ cert: tls?.cert,
269
+ key: tls?.key,
270
+ ca: tls?.ca,
271
+ rejectUnauthorized: tls?.rejectUnauthorized,
272
+ };
273
+ }
274
+ }
186
275
  /**
187
276
  * Disconnect from all units of this network device.
188
277
  *
@@ -307,18 +396,42 @@ export class SunspecModbusClient {
307
396
  }
308
397
  }
309
398
  /**
310
- * Open a new Modbus instance for one unit ID and wire up its fault-tolerant reader.
311
- * On any failure, the just-opened instance (if any) is closed so we never leak. Caller must
312
- * hold the connection lock and ensure the unit is not already open.
399
+ * Open a unit, retrying the connect on a transient failure per the resilience config
400
+ * ({@link IModbusResilienceConfig.connectRetries}). Each attempt is a full {@link _openUnitOnce}
401
+ * — which independently bounds its connect at {@link IModbusResilienceConfig.connectTimeoutMs}
402
+ * and tears down any half-open candidate before rethrowing — so retries never leak a socket.
403
+ *
404
+ * `override` lets a caller tune this single open: {@link probeUnit} passes `connectRetries: 0`
405
+ * and a shorter `connectTimeoutMs` to fast-fail a speculative scan; omitted fields fall back to
406
+ * the client's resilience config.
407
+ */
408
+ async _openUnit(host, port, unitId, override) {
409
+ const connectTimeoutMs = override?.connectTimeoutMs ?? this.resilience.connectTimeoutMs;
410
+ const attempts = (override?.connectRetries ?? this.resilience.connectRetries) + 1;
411
+ await retryAsync(() => this._openUnitOnce(host, port, unitId, connectTimeoutMs), {
412
+ attempts,
413
+ delayMs: this.resilience.connectRetryDelayMs,
414
+ onRetry: (error, attempt) => console.warn(`SunspecModbusClient: connect to ${host}:${port} unit ${unitId} failed ` +
415
+ `(attempt ${attempt}/${attempts}): ${error instanceof Error ? error.message : String(error)}; ` +
416
+ `retrying in ${this.resilience.connectRetryDelayMs}ms`),
417
+ });
418
+ }
419
+ /**
420
+ * Open a new Modbus instance for one unit ID and wire up its fault-tolerant reader. Bounds the
421
+ * connect at `connectTimeoutMs`. On any failure, the just-opened instance (if any) is closed so
422
+ * we never leak. Caller must hold the connection lock and ensure the unit is not already open.
313
423
  */
314
- async _openUnit(host, port, unitId) {
424
+ async _openUnitOnce(host, port, unitId, connectTimeoutMs = this.resilience.connectTimeoutMs) {
315
425
  let candidate = null;
316
426
  try {
317
- candidate = await this.energyApp.useModbus().connect({
427
+ // Enforce the connect budget ourselves in addition to forwarding it as the transport's
428
+ // `timeout`: the transport applies it to the TCP handshake, but a sleeping/half-open peer
429
+ // can still leave the returned promise pending — bound it independently.
430
+ candidate = await this.withTimeout('connect', unitId, connectTimeoutMs, () => this.energyApp.useModbus().connect({
318
431
  host,
319
432
  port,
320
433
  unitId,
321
- timeout: 5000,
434
+ timeout: connectTimeoutMs,
322
435
  useTls: this.connectionParams?.useTls,
323
436
  cert: this.connectionParams?.cert,
324
437
  key: this.connectionParams?.key,
@@ -326,22 +439,23 @@ export class SunspecModbusClient {
326
439
  rejectUnauthorized: this.connectionParams?.rejectUnauthorized,
327
440
  noParallelRequests: this.pacing.noParallelRequests,
328
441
  waitBetweenMessagesMs: this.pacing.waitBetweenMessagesMs
329
- });
442
+ }));
330
443
  if (!candidate) {
331
444
  throw new Error(`useModbus().connect returned null for ${host}:${port} unit ${unitId}`);
332
445
  }
333
446
  const reader = new EnergyAppModbusFaultTolerantReader(candidate, this.connectionHealth);
334
447
  this.modbusInstances.set(unitId, candidate);
335
448
  this.faultTolerantReaders.set(unitId, reader);
449
+ // Fresh socket: clear any prior poison and start the freshness clock so a just-opened
450
+ // unit isn't immediately judged stale.
451
+ this.poisonedUnits.delete(unitId);
452
+ this.lastOkAtByUnit.set(unitId, Date.now());
336
453
  this.connectionHealth.recordSuccess();
337
454
  this.recordOpen();
338
455
  }
339
456
  catch (err) {
340
457
  if (candidate) {
341
- try {
342
- await candidate.disconnect();
343
- }
344
- catch { /* ignore */ }
458
+ await this.disconnectInstanceBounded(candidate, unitId);
345
459
  }
346
460
  this.modbusInstances.delete(unitId);
347
461
  this.faultTolerantReaders.delete(unitId);
@@ -359,15 +473,31 @@ export class SunspecModbusClient {
359
473
  this.faultTolerantReaders.delete(unitId);
360
474
  this.discoveredModelsByUnit.delete(unitId);
361
475
  this.discoveredModelListByUnit.delete(unitId);
476
+ // Drop per-unit resilience state so a later reopen starts clean.
477
+ this.poisonedUnits.delete(unitId);
478
+ this.lastOkAtByUnit.delete(unitId);
362
479
  if (instance) {
363
- try {
364
- await instance.disconnect();
365
- }
366
- catch { /* ignore */ }
480
+ await this.disconnectInstanceBounded(instance, unitId);
367
481
  }
368
482
  if (wasOpen)
369
483
  this.recordClose();
370
484
  }
485
+ /**
486
+ * Close an instance under a hard time budget. A half-open socket can hang even on disconnect();
487
+ * left unbounded that would wedge the connection lock and stall every later connect/disconnect.
488
+ * Swallows all errors (including the timeout) — a close that can't complete is abandoned.
489
+ */
490
+ async disconnectInstanceBounded(instance, unitId) {
491
+ try {
492
+ await this.withTimeout('disconnect', unitId, this.resilience.disconnectTimeoutMs, () => instance.disconnect());
493
+ }
494
+ catch (err) {
495
+ if (err instanceof ModbusOperationTimeoutError) {
496
+ console.warn(`SunspecModbusClient: disconnect of unit ${unitId} timed out after ${this.resilience.disconnectTimeoutMs}ms — abandoning socket`);
497
+ }
498
+ /* ignore: best-effort close */
499
+ }
500
+ }
371
501
  /**
372
502
  * Run `fn` with exclusive access to connection-state transitions. Subsequent calls queue
373
503
  * behind any in-flight one. A rejected `fn` does not poison the chain for later callers.
@@ -389,10 +519,74 @@ export class SunspecModbusClient {
389
519
  */
390
520
  runExclusive(unitId, fn) {
391
521
  const prev = this.txChains.get(unitId) ?? Promise.resolve();
392
- const run = prev.then(fn, fn);
522
+ const guarded = () => this.guardTransaction(unitId, fn);
523
+ const run = prev.then(guarded, guarded);
393
524
  this.txChains.set(unitId, run.catch(() => undefined));
394
525
  return run;
395
526
  }
527
+ /**
528
+ * Wrap one serialized transaction with the per-operation timeout and half-open bookkeeping.
529
+ * On success, stamp the unit's freshness clock. On timeout, poison the unit so no further
530
+ * transaction reuses the hung socket before the reconnect path recycles it. A unit already
531
+ * poisoned refuses I/O outright — the abandoned in-flight response could otherwise land later
532
+ * and desync the next transaction's framing.
533
+ */
534
+ async guardTransaction(unitId, fn) {
535
+ if (this.poisonedUnits.has(unitId)) {
536
+ throw new Error(`Modbus unit ${unitId} socket is poisoned (awaiting reconnect) — transaction refused`);
537
+ }
538
+ try {
539
+ const result = await this.withTimeout('transaction', unitId, this.resilience.readTimeoutMs, fn);
540
+ this.lastOkAtByUnit.set(unitId, Date.now());
541
+ return result;
542
+ }
543
+ catch (error) {
544
+ if (error instanceof ModbusOperationTimeoutError) {
545
+ this.poisonUnit(unitId, error);
546
+ }
547
+ throw error;
548
+ }
549
+ }
550
+ /**
551
+ * Race `fn` against a timeout. If the timeout wins, reject with a {@link ModbusOperationTimeoutError};
552
+ * the abandoned `fn` promise keeps running (JS can't cancel it) but is no longer awaited. The
553
+ * timer is always cleared so a fast `fn` doesn't keep the event loop alive.
554
+ */
555
+ withTimeout(operation, unitId, timeoutMs, fn) {
556
+ let timer;
557
+ const timeout = new Promise((_, reject) => {
558
+ timer = setTimeout(() => reject(new ModbusOperationTimeoutError(operation, unitId, timeoutMs)), timeoutMs);
559
+ });
560
+ return Promise.race([fn(), timeout]).finally(() => {
561
+ if (timer !== undefined)
562
+ clearTimeout(timer);
563
+ });
564
+ }
565
+ /**
566
+ * Mark a unit's socket as poisoned after a timeout and reflect the hang in the shared health
567
+ * gate immediately, so isHealthy() flips false this cycle instead of after the coarse
568
+ * 5-failure / 5-minute-staleness thresholds. Idempotent; only logs on the first poison.
569
+ */
570
+ poisonUnit(unitId, error) {
571
+ if (!this.poisonedUnits.has(unitId)) {
572
+ console.warn(`SunspecModbusClient: ${error.message} — poisoning unit ${unitId} socket; reconnect path will recycle it`);
573
+ }
574
+ this.poisonedUnits.add(unitId);
575
+ this.connectionHealth.recordFailure(error);
576
+ }
577
+ /**
578
+ * A unit's socket is stale when the transport still reports it connected but no successful
579
+ * transaction has completed within staleSocketMs — the signature of a half-open link where
580
+ * the peer silently stopped answering. Units with no successful op yet are never stale.
581
+ */
582
+ isStale(unitId) {
583
+ if (this.resilience.staleSocketMs <= 0)
584
+ return false;
585
+ const last = this.lastOkAtByUnit.get(unitId);
586
+ if (last === undefined)
587
+ return false;
588
+ return Date.now() - last > this.resilience.staleSocketMs;
589
+ }
396
590
  recordOpen() {
397
591
  this.openCount++;
398
592
  const expected = this.modbusInstances.size;
@@ -2230,10 +2424,19 @@ export class SunspecModbusClient {
2230
2424
  return this.modbusInstances.has(unitId);
2231
2425
  }
2232
2426
  /**
2233
- * Check if a specific unit's connection is healthy
2427
+ * Check if a specific unit's connection is healthy. Beyond the shared health counter, a unit is
2428
+ * unhealthy if its socket has been poisoned by a timed-out transaction or has gone stale
2429
+ * (half-open) — both flip false immediately so the device's readData()/tryReconnect() path
2430
+ * recycles the socket rather than trusting a hung link.
2234
2431
  */
2235
2432
  isHealthy(unitId) {
2236
- return this.modbusInstances.has(unitId) && this.connectionHealth.isHealthy();
2433
+ if (!this.modbusInstances.has(unitId))
2434
+ return false;
2435
+ if (this.poisonedUnits.has(unitId))
2436
+ return false;
2437
+ if (this.isStale(unitId))
2438
+ return false;
2439
+ return this.connectionHealth.isHealthy();
2237
2440
  }
2238
2441
  /**
2239
2442
  * Get connection health details (shared across all units on this network device)
package/dist/version.d.ts CHANGED
@@ -5,7 +5,7 @@
5
5
  /**
6
6
  * Current version of the enyo Energy App SDK.
7
7
  */
8
- export declare const SDK_VERSION = "0.0.98";
8
+ export declare const SDK_VERSION = "0.0.100";
9
9
  /**
10
10
  * Gets the current SDK version.
11
11
  * @returns The semantic version string of the SDK
package/dist/version.js CHANGED
@@ -5,7 +5,7 @@
5
5
  /**
6
6
  * Current version of the enyo Energy App SDK.
7
7
  */
8
- export const SDK_VERSION = '0.0.98';
8
+ export const SDK_VERSION = '0.0.100';
9
9
  /**
10
10
  * Gets the current SDK version.
11
11
  * @returns The semantic version string of the SDK
package/package.json CHANGED
@@ -1,6 +1,6 @@
1
1
  {
2
2
  "name": "@enyo-energy/sunspec-sdk",
3
- "version": "0.0.98",
3
+ "version": "0.0.100",
4
4
  "description": "enyo Energy Sunspec SDK",
5
5
  "type": "module",
6
6
  "main": "dist/index.js",