@enyo-energy/sunspec-sdk 0.0.96 → 0.0.98

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
@@ -2,6 +2,7 @@
2
2
  Object.defineProperty(exports, "__esModule", { value: true });
3
3
  exports.SunspecMeter = exports.SunspecBattery = exports.SunspecInverter = exports.BaseSunspecDevice = void 0;
4
4
  exports.detectFeaturesFromRegisters = detectFeaturesFromRegisters;
5
+ exports.sumMpptBatteryPowerW = sumMpptBatteryPowerW;
5
6
  exports.selectLiveBatteryPowerW = selectLiveBatteryPowerW;
6
7
  exports.filterFeaturesByCalibrationResult = filterFeaturesByCalibrationResult;
7
8
  const sunspec_interfaces_js_1 = require("./sunspec-interfaces.cjs");
@@ -336,6 +337,25 @@ class BaseSunspecDevice {
336
337
  }
337
338
  }
338
339
  exports.BaseSunspecDevice = BaseSunspecDevice;
340
+ /**
341
+ * Coerce a possibly-`undefined`, `NaN`, or `±Infinity` register value to a finite
342
+ * number, substituting `fallback` (default `0`) otherwise. SunSpec scale-factor
343
+ * decodes and IEEE-754 float models can surface `NaN`/`Infinity` for a
344
+ * NOT_IMPLEMENTED or corrupt register, and `typeof NaN === 'number'` /
345
+ * `Infinity > 0 === true` slip past naive guards — this is the single choke point
346
+ * that keeps every published power/voltage/energy value finite.
347
+ */
348
+ function finiteOr(value, fallback = 0) {
349
+ return typeof value === 'number' && Number.isFinite(value) ? value : fallback;
350
+ }
351
+ /**
352
+ * Like {@link finiteOr} but yields `undefined` for a non-finite/absent value, for
353
+ * optional reading fields (voltageL2/L3, acEnergyWh, batteryPowerW) where "no
354
+ * reliable value" is more honest than a fabricated `0`.
355
+ */
356
+ function finiteOrUndefined(value) {
357
+ return typeof value === 'number' && Number.isFinite(value) ? value : undefined;
358
+ }
339
359
  /**
340
360
  * Sunspec Inverter implementation using dynamic model discovery
341
361
  */
@@ -496,8 +516,13 @@ class SunspecInverter extends BaseSunspecDevice {
496
516
  // to Connected. No-op unless this device is still marked offline.
497
517
  await this.reassertConnectedIfRecovered();
498
518
  if (inverterData) {
499
- const { pvPowerW, source: pvPowerSource } = this.selectPvPowerW(dcStrings, inverterData);
500
- console.debug(`Got PV Power from ${pvPowerSource}: ${pvPowerW}W`);
519
+ // Build the same decoupled reading a direct getInverterReading() caller
520
+ // would get, then wrap it in the data-bus message. The battery-adjusted
521
+ // power is what we publish; meterValueWh is sanitized only here on the
522
+ // publish path (the raw reading intentionally leaves it unguarded).
523
+ const batteryPowerW = await this.fetchAcCorrectionBatteryPowerW(dcStrings.length, mpptDataList);
524
+ const reading = this.buildInverterReading(inverterData, dcStrings, batteryPowerW);
525
+ console.debug(`Got PV Power from ${reading.powerOrigin}: ${reading.inverterPowerW}W (inverter total raw ${reading.inverterPowerWRaw}W, DC strings ${reading.inverterPowerWDcStrings}W)`);
501
526
  const inverterMessage = {
502
527
  id: (0, node_crypto_1.randomUUID)(),
503
528
  message: enyo_data_bus_value_js_1.EnyoDataBusMessageEnum.InverterValuesUpdateV1,
@@ -508,14 +533,14 @@ class SunspecInverter extends BaseSunspecDevice {
508
533
  timestampIso: timestamp.toISOString(),
509
534
  resolution,
510
535
  data: {
511
- pvPowerW,
536
+ pvPowerW: reading.inverterPowerW,
512
537
  activePowerLimitationW: inverterSettings?.WMax,
513
- state: this.mapOperatingState(inverterData.operatingState),
514
- voltageL1: inverterData.voltageAN || 0,
515
- voltageL2: inverterData.voltageBN ?? undefined,
516
- voltageL3: inverterData.voltageCN ?? undefined,
538
+ state: reading.state,
539
+ voltageL1: reading.voltageL1,
540
+ voltageL2: reading.voltageL2,
541
+ voltageL3: reading.voltageL3,
517
542
  meterValueWh: this.sanitizeAcEnergyWh(inverterData.acEnergy, inverterData.acEnergyScaleFactor),
518
- strings: dcStrings
543
+ strings: reading.strings
519
544
  }
520
545
  };
521
546
  messages.push(inverterMessage);
@@ -818,6 +843,93 @@ class SunspecInverter extends BaseSunspecDevice {
818
843
  };
819
844
  return stateMap[state] || enyo_data_bus_value_js_1.EnyoInverterStateEnum.Off;
820
845
  }
846
+ /**
847
+ * Read a decoupled snapshot of the inverter's live telemetry — PV power (raw
848
+ * and battery-adjusted), its resolved origin, operating state, voltages, AC
849
+ * energy and per-string DC data — WITHOUT constructing or sending any data-bus
850
+ * message. The consumer decides whether and how to publish it.
851
+ *
852
+ * This is the clean read primitive the SDK's own polling (`readData`) is built
853
+ * on, so a direct caller gets exactly the same numbers the bus would carry
854
+ * (except `acEnergyWh`, which is returned raw here and sanitized only on the
855
+ * publish path — see {@link SunspecInverterReading.acEnergyWh}).
856
+ *
857
+ * Returns `null` when not connected (after a reconnect attempt) or when the
858
+ * device exposes no readable inverter model.
859
+ */
860
+ async getInverterReading() {
861
+ try {
862
+ if (!this.isConnected()) {
863
+ await this.tryReconnect();
864
+ if (!this.isConnected())
865
+ return null;
866
+ }
867
+ const inverterData = await this.sunspecClient.readInverterData(this.unitId);
868
+ if (!inverterData)
869
+ return null;
870
+ const mpptDataList = await this.sunspecClient.readAllMPPTData(this.unitId);
871
+ const dcStrings = this.mapMPPTToStrings(mpptDataList ?? []);
872
+ const batteryPowerW = await this.fetchAcCorrectionBatteryPowerW(dcStrings.length, mpptDataList ?? []);
873
+ return this.buildInverterReading(inverterData, dcStrings, batteryPowerW);
874
+ }
875
+ catch (error) {
876
+ // Bullet-proof contract: a decode/comms fault never propagates to the
877
+ // caller — it surfaces as a null reading, same as "no readable model".
878
+ console.warn(`Notify_Devs: ${this.constructor.name} ${this.applianceId}: getInverterReading failed: ${error}`);
879
+ return null;
880
+ }
881
+ }
882
+ /**
883
+ * Fetch the live battery power (signed: positive = charging, negative =
884
+ * discharging) that {@link inverterTotalPvPowerW} backs out of the AC fallback.
885
+ * Only fetched when the inverter-total fallback will actually be used — the
886
+ * correction is irrelevant for the MPPT-string path — so a device with working
887
+ * strings never pays the extra battery read. Prefers the Model 160
888
+ * `StCha`/`StDisCha` strings, falling back to Model 124/802. `undefined` when
889
+ * no correction is needed or no live battery source exists.
890
+ */
891
+ async fetchAcCorrectionBatteryPowerW(dcStringCount, mpptDataList) {
892
+ if (!this.wouldUseInverterTotal(dcStringCount))
893
+ return undefined;
894
+ const mpptBatteryPowerW = sumMpptBatteryPowerW(mpptDataList);
895
+ if (mpptBatteryPowerW !== undefined)
896
+ return mpptBatteryPowerW;
897
+ const batteryData = await this.sunspecClient.readBatteryData(this.unitId);
898
+ return selectLiveBatteryPowerW(undefined, batteryData);
899
+ }
900
+ /**
901
+ * Assemble a {@link SunspecInverterReading} from an already-read register set.
902
+ * Pure (no I/O, no side effects) so both `getInverterReading` and the polling
903
+ * `readData` produce identical readings from a single shared code path.
904
+ */
905
+ buildInverterReading(inverterData, dcStrings, batteryPowerW) {
906
+ // Independent breakdown: compute each candidate power regardless of which the
907
+ // configured source selects, so nothing is hidden by the selection.
908
+ // - inverterPowerWDcStrings: the summed MPPT DC strings (always).
909
+ // - inverterPowerWRaw: the inverter's own total (DCW→AC), uncorrected (always).
910
+ // - inverterPowerW: the auto-calc value to use — selected source,
911
+ // battery-adjusted (via selectPvPowerW, overridable).
912
+ const dcStringsW = this.sumDcStringsW(dcStrings);
913
+ const inverterTotal = this.inverterTotalPvPowerW(inverterData, batteryPowerW);
914
+ const selected = this.selectPvPowerW(dcStrings, inverterData, batteryPowerW);
915
+ // Final clamp: the helpers already sanitize, but re-assert the finite/≥0
916
+ // contract here so an override of selectPvPowerW can never leak a non-finite
917
+ // or negative value onto the reading.
918
+ return {
919
+ inverterPowerW: Math.max(0, finiteOr(selected.batteryAdjustedPowerW)),
920
+ inverterPowerWRaw: Math.max(0, finiteOr(inverterTotal.rawPowerW)),
921
+ inverterPowerWDcStrings: Math.max(0, finiteOr(dcStringsW)),
922
+ powerOrigin: selected.origin,
923
+ batteryPowerW: finiteOrUndefined(batteryPowerW),
924
+ state: this.mapOperatingState(inverterData.operatingState),
925
+ operatingState: finiteOrUndefined(inverterData.operatingState),
926
+ voltageL1: finiteOr(inverterData.voltageAN),
927
+ voltageL2: finiteOrUndefined(inverterData.voltageBN),
928
+ voltageL3: finiteOrUndefined(inverterData.voltageCN),
929
+ acEnergyWh: finiteOrUndefined(inverterData.acEnergy),
930
+ strings: Array.isArray(dcStrings) ? dcStrings : [],
931
+ };
932
+ }
821
933
  /**
822
934
  * PV production in Watt, sourced according to the configured `pvPowerSource`:
823
935
  *
@@ -834,31 +946,73 @@ class SunspecInverter extends BaseSunspecDevice {
834
946
  * Both inverter-total steps require a strictly positive value, so NOT_IMPLEMENTED
835
947
  * DCW (decodes to 0) falls through to AC, and a negative AC reading (e.g. a hybrid
836
948
  * importing from grid) falls through to 0 rather than reporting negative production.
837
- * Edge case: in Auto/Inverter a hybrid discharging its battery while its MPPT is
838
- * unreadable reports AC (incl. battery) rather than 0 — acceptable, and strictly
839
- * better than reporting 0.
949
+ *
950
+ * The AC fallback backs out battery power via `batteryPowerW` (signed: positive =
951
+ * charging, negative = discharging). A hybrid's AC total is PV − charge + discharge,
952
+ * so real PV = AC + batteryPowerW. Without this, a battery discharging at night while
953
+ * the MPPT is unreadable would be reported as phantom PV production. `batteryPowerW`
954
+ * is undefined when no live battery source is available, in which case AC is used
955
+ * uncorrected (still better than reporting 0).
956
+ *
957
+ * The returned `pvPowerW` is always clamped to ≥ 0 — PV production is non-negative by
958
+ * definition and must never surface as a negative value on the data bus.
840
959
  */
841
- selectPvPowerW(dcStrings, inverterData) {
842
- const stringSumW = dcStrings.reduce((sum, s) => sum + (s.powerW || 0), 0);
843
- const useStrings = this.pvPowerSource === sunspec_interfaces_js_1.SunspecPvPowerSource.Mppt ||
844
- (this.pvPowerSource === sunspec_interfaces_js_1.SunspecPvPowerSource.Auto && dcStrings.length > 0);
845
- if (useStrings) {
846
- return { pvPowerW: stringSumW, source: 'DC strings' };
960
+ selectPvPowerW(dcStrings, inverterData, batteryPowerW) {
961
+ const strings = Array.isArray(dcStrings) ? dcStrings : [];
962
+ if (!this.wouldUseInverterTotal(strings.length)) {
963
+ const stringSumW = this.sumDcStringsW(strings);
964
+ // MPPT strings are already pure PV — raw and battery-adjusted coincide.
965
+ return { rawPowerW: stringSumW, batteryAdjustedPowerW: stringSumW, origin: sunspec_interfaces_js_1.SunspecPvPowerOrigin.MpptStrings };
847
966
  }
848
- return this.inverterTotalPvPowerW(inverterData);
967
+ return this.inverterTotalPvPowerW(inverterData, batteryPowerW);
849
968
  }
850
969
  /**
851
- * Inverter total PV power from Model 101: DCW when strictly positive, else AC when
852
- * strictly positive, else 0. See {@link selectPvPowerW} for why positivity matters.
970
+ * Whether {@link selectPvPowerW} will source PV from the inverter total (rather than
971
+ * the summed MPPT strings) for the given string count. Mppt never does; Inverter
972
+ * always does; Auto does only when there are no strings. Exposed so `readData` can
973
+ * decide up front whether it needs to fetch battery power for the AC correction.
853
974
  */
854
- inverterTotalPvPowerW(inverterData) {
855
- if (typeof inverterData.dcPower === 'number' && inverterData.dcPower > 0) {
856
- return { pvPowerW: inverterData.dcPower, source: 'DC power (Model 101)' };
857
- }
858
- if (typeof inverterData.acPower === 'number' && inverterData.acPower > 0) {
859
- return { pvPowerW: inverterData.acPower, source: 'AC power (Model 101)' };
860
- }
861
- return { pvPowerW: 0, source: 'none' };
975
+ wouldUseInverterTotal(dcStringCount) {
976
+ if (this.pvPowerSource === sunspec_interfaces_js_1.SunspecPvPowerSource.Mppt)
977
+ return false;
978
+ if (this.pvPowerSource === sunspec_interfaces_js_1.SunspecPvPowerSource.Inverter)
979
+ return true;
980
+ return dcStringCount === 0; // Auto
981
+ }
982
+ /**
983
+ * Inverter total PV power from Model 101: DCW when strictly positive, else AC (with
984
+ * battery power backed out) when the result is strictly positive, else 0. See
985
+ * {@link selectPvPowerW} for the battery correction and why positivity matters.
986
+ */
987
+ inverterTotalPvPowerW(inverterData, batteryPowerW) {
988
+ // finiteOr collapses NaN/Infinity to 0 so a corrupt decode fails the `> 0`
989
+ // guard (Infinity would otherwise pass `typeof === 'number' && > 0`).
990
+ const dcW = finiteOr(inverterData.dcPower);
991
+ if (dcW > 0) {
992
+ // Inverter DC total is already pure PV — no battery correction applies.
993
+ return { rawPowerW: dcW, batteryAdjustedPowerW: dcW, origin: sunspec_interfaces_js_1.SunspecPvPowerOrigin.InverterDc };
994
+ }
995
+ const acW = finiteOr(inverterData.acPower);
996
+ if (acW > 0) {
997
+ // AC = PV − charge + discharge on a hybrid; batteryPowerW is signed
998
+ // (positive = charging, negative = discharging), so PV = AC + batteryPowerW.
999
+ // rawPowerW keeps the uncorrected AC total; batteryAdjustedPowerW backs the
1000
+ // battery out and is clamped to ≥ 0. finiteOr(batteryPowerW) guarantees the
1001
+ // sum stays finite even if the battery source returned garbage.
1002
+ const correctedW = Math.max(0, acW + finiteOr(batteryPowerW));
1003
+ return { rawPowerW: acW, batteryAdjustedPowerW: correctedW, origin: sunspec_interfaces_js_1.SunspecPvPowerOrigin.InverterAc };
1004
+ }
1005
+ return { rawPowerW: 0, batteryAdjustedPowerW: 0, origin: sunspec_interfaces_js_1.SunspecPvPowerOrigin.None };
1006
+ }
1007
+ /**
1008
+ * Summed per-string MPPT DC power (Model 160), battery strings already filtered
1009
+ * out by {@link mapMPPTToStrings}. finiteOr per-string so one NaN/Infinity powerW
1010
+ * cannot poison the sum; clamped to ≥ 0. Feeds both the MPPT-source selection and
1011
+ * the always-reported {@link SunspecInverterReading.inverterPowerWDcStrings}.
1012
+ */
1013
+ sumDcStringsW(dcStrings) {
1014
+ const strings = Array.isArray(dcStrings) ? dcStrings : [];
1015
+ return Math.max(0, strings.reduce((sum, s) => sum + finiteOr(s?.powerW), 0));
862
1016
  }
863
1017
  /**
864
1018
  * Map MPPT data to DC string structure for data bus
@@ -1089,6 +1243,31 @@ function detectFeaturesFromRegisters(batteryData) {
1089
1243
  * Exported as a free function so the preference logic can be unit-tested
1090
1244
  * without the full `SunspecBattery` scaffold.
1091
1245
  */
1246
+ /**
1247
+ * Sum battery charge/discharge power from Model 160 MPPT strings.
1248
+ *
1249
+ * - `StCha 3` → charging power (added, positive)
1250
+ * - `StDisCha 4` → discharging power (subtracted)
1251
+ *
1252
+ * The result follows the battery-power sign convention used across this file:
1253
+ * positive = charging, negative = discharging. Returns `undefined` when neither
1254
+ * battery string is present, so callers can fall through to another source.
1255
+ *
1256
+ * Exported as a free function so it can be unit-tested and reused by both the
1257
+ * SunspecBattery live-power path and the SunspecInverter AC-fallback correction.
1258
+ */
1259
+ function sumMpptBatteryPowerW(mpptDataList) {
1260
+ let batteryPowerW;
1261
+ for (const mppt of mpptDataList) {
1262
+ if (mppt.stringId === 'StCha 3' && mppt.dcPower !== undefined) {
1263
+ batteryPowerW = (batteryPowerW ?? 0) + mppt.dcPower;
1264
+ }
1265
+ else if (mppt.stringId === 'StDisCha 4' && mppt.dcPower !== undefined) {
1266
+ batteryPowerW = (batteryPowerW ?? 0) - mppt.dcPower;
1267
+ }
1268
+ }
1269
+ return batteryPowerW;
1270
+ }
1092
1271
  function selectLiveBatteryPowerW(mpptBatteryPowerW, batteryData) {
1093
1272
  if (mpptBatteryPowerW !== undefined) {
1094
1273
  return mpptBatteryPowerW;
@@ -1342,6 +1521,43 @@ class SunspecBattery extends BaseSunspecDevice {
1342
1521
  return undefined;
1343
1522
  }
1344
1523
  }
1524
+ /**
1525
+ * Read a decoupled snapshot of the battery's live telemetry — state of charge,
1526
+ * signed power (positive = charging, negative = discharging) and charge state —
1527
+ * WITHOUT constructing or sending any data-bus message. The consumer decides
1528
+ * whether and how to publish it.
1529
+ *
1530
+ * This is the clean read primitive the SDK's own polling (`readData`) is built
1531
+ * on, so a direct caller gets exactly the same numbers the bus would carry.
1532
+ * Returns `null` when not connected (after a reconnect attempt) or when the
1533
+ * device exposes no readable battery model.
1534
+ */
1535
+ async getBatteryReading() {
1536
+ if (!this.isConnected()) {
1537
+ await this.tryReconnect();
1538
+ if (!this.isConnected())
1539
+ return null;
1540
+ }
1541
+ const batteryData = await this.sunspecClient.readBatteryData(this.unitId);
1542
+ if (!batteryData)
1543
+ return null;
1544
+ const mpptDataList = await this.sunspecClient.readAllMPPTData(this.unitId);
1545
+ const mpptBatteryPowerW = this.extractBatteryPowerFromMPPT(mpptDataList);
1546
+ return this.buildBatteryReading(batteryData, mpptBatteryPowerW);
1547
+ }
1548
+ /**
1549
+ * Assemble a {@link SunspecBatteryReading} from an already-read register set.
1550
+ * Pure (no I/O, no side effects) so both `getBatteryReading` and the polling
1551
+ * `readData` produce identical readings from a single shared code path. See
1552
+ * {@link selectLiveBatteryPowerW} for the power source-preference rationale.
1553
+ */
1554
+ buildBatteryReading(batteryData, mpptBatteryPowerW) {
1555
+ return {
1556
+ soc: batteryData.soc || batteryData.chaState || 0,
1557
+ powerW: selectLiveBatteryPowerW(mpptBatteryPowerW, batteryData),
1558
+ state: this.mapToEnyoBatteryState(batteryData.chaSt),
1559
+ };
1560
+ }
1345
1561
  /**
1346
1562
  * Update battery data and return data bus messages
1347
1563
  */
@@ -1368,12 +1584,13 @@ class SunspecBattery extends BaseSunspecDevice {
1368
1584
  // to Connected. No-op unless this device is still marked offline.
1369
1585
  await this.reassertConnectedIfRecovered();
1370
1586
  if (batteryData) {
1371
- // See `selectLiveBatteryPowerW` for the source-preference rationale.
1372
- const batteryPowerW = selectLiveBatteryPowerW(mpptBatteryPowerW, batteryData);
1587
+ // Build the same decoupled reading a direct getBatteryReading() caller
1588
+ // would get, then wrap it in the data-bus message.
1589
+ const reading = this.buildBatteryReading(batteryData, mpptBatteryPowerW);
1373
1590
  // Feed the calibration driver's synchronous power cache. No-op when calibration
1374
1591
  // was never configured.
1375
- if (batteryPowerW !== undefined && this.calibrationDriver) {
1376
- this.calibrationDriver.updateBatteryPowerCache(batteryPowerW);
1592
+ if (reading.powerW !== undefined && this.calibrationDriver) {
1593
+ this.calibrationDriver.updateBatteryPowerCache(reading.powerW);
1377
1594
  }
1378
1595
  const batteryMessage = {
1379
1596
  id: (0, node_crypto_1.randomUUID)(),
@@ -1385,9 +1602,9 @@ class SunspecBattery extends BaseSunspecDevice {
1385
1602
  timestampIso: timestamp.toISOString(),
1386
1603
  resolution,
1387
1604
  data: {
1388
- batterySoC: batteryData.soc || batteryData.chaState || 0,
1389
- batteryPowerW,
1390
- state: this.mapToEnyoBatteryState(batteryData.chaSt),
1605
+ batterySoC: reading.soc,
1606
+ batteryPowerW: reading.powerW,
1607
+ state: reading.state,
1391
1608
  }
1392
1609
  };
1393
1610
  messages.push(batteryMessage);
@@ -1428,18 +1645,7 @@ class SunspecBattery extends BaseSunspecDevice {
1428
1645
  * StDisCha 4: Battery discharging power (negative)
1429
1646
  */
1430
1647
  extractBatteryPowerFromMPPT(mpptDataList) {
1431
- let batteryPowerW;
1432
- mpptDataList.forEach((mppt) => {
1433
- if (mppt.stringId === 'StCha 3' && mppt.dcPower !== undefined) {
1434
- // Charging power is positive
1435
- batteryPowerW = (batteryPowerW || 0) + mppt.dcPower;
1436
- }
1437
- else if (mppt.stringId === 'StDisCha 4' && mppt.dcPower !== undefined) {
1438
- // Discharging power is negative
1439
- batteryPowerW = (batteryPowerW || 0) - mppt.dcPower;
1440
- }
1441
- });
1442
- return batteryPowerW;
1648
+ return sumMpptBatteryPowerW(mpptDataList);
1443
1649
  }
1444
1650
  /**
1445
1651
  * Determine battery state from MPPT strings
@@ -1,4 +1,4 @@
1
- import { type IRetryConfig, type SunspecBatteryBaseData, SunspecBatteryCapability, type SunspecBatteryControls, type SunspecBatteryData, type SunspecBatteryFeatureMode, type SunspecInverterData, SunspecInverterCapability, SunspecPvPowerSource, SunspecMeterCapability, type SunspecMPPTData, SunspecStorageMode } from "./sunspec-interfaces.cjs";
1
+ import { type IRetryConfig, type SunspecBatteryBaseData, SunspecBatteryCapability, type SunspecBatteryControls, type SunspecBatteryData, type SunspecBatteryFeatureMode, type SunspecInverterData, SunspecInverterCapability, SunspecPvPowerSource, SunspecPvPowerOrigin, type SunspecInverterReading, type SunspecBatteryReading, SunspecMeterCapability, type SunspecMPPTData, SunspecStorageMode } from "./sunspec-interfaces.cjs";
2
2
  import { ApplianceManager, EnergyApp } from "@enyo-energy/energy-app-sdk";
3
3
  import { type EnyoAppliance, type EnyoApplianceErrorCode, EnyoApplianceName } from "@enyo-energy/energy-app-sdk/dist/types/enyo-appliance.js";
4
4
  import { EnyoNetworkDevice } from "@enyo-energy/energy-app-sdk/dist/types/enyo-network-device.js";
@@ -122,6 +122,18 @@ export declare abstract class BaseSunspecDevice {
122
122
  */
123
123
  protected buildSnapshotService<T>(onRestore: (snapshot: CalibrationSnapshot<T>, reason: RestoreReason) => Promise<void>): SnapshotService<T> | undefined;
124
124
  }
125
+ /**
126
+ * The result of the configured PV-source selection: the picked source's raw and
127
+ * battery-adjusted power plus its resolved origin. Internal to the
128
+ * source-selection helpers (`selectPvPowerW` / `inverterTotalPvPowerW`); the
129
+ * public {@link SunspecInverterReading} exposes an independent breakdown built
130
+ * from these plus the always-computed DC-strings and inverter-total figures.
131
+ */
132
+ type SunspecPvPower = {
133
+ rawPowerW: number;
134
+ batteryAdjustedPowerW: number;
135
+ origin: SunspecPvPowerOrigin;
136
+ };
125
137
  /**
126
138
  * Sunspec Inverter implementation using dynamic model discovery
127
139
  */
@@ -239,6 +251,37 @@ export declare class SunspecInverter extends BaseSunspecDevice {
239
251
  */
240
252
  getPowerProductionLimit(): Promise<number | null>;
241
253
  private mapOperatingState;
254
+ /**
255
+ * Read a decoupled snapshot of the inverter's live telemetry — PV power (raw
256
+ * and battery-adjusted), its resolved origin, operating state, voltages, AC
257
+ * energy and per-string DC data — WITHOUT constructing or sending any data-bus
258
+ * message. The consumer decides whether and how to publish it.
259
+ *
260
+ * This is the clean read primitive the SDK's own polling (`readData`) is built
261
+ * on, so a direct caller gets exactly the same numbers the bus would carry
262
+ * (except `acEnergyWh`, which is returned raw here and sanitized only on the
263
+ * publish path — see {@link SunspecInverterReading.acEnergyWh}).
264
+ *
265
+ * Returns `null` when not connected (after a reconnect attempt) or when the
266
+ * device exposes no readable inverter model.
267
+ */
268
+ getInverterReading(): Promise<SunspecInverterReading | null>;
269
+ /**
270
+ * Fetch the live battery power (signed: positive = charging, negative =
271
+ * discharging) that {@link inverterTotalPvPowerW} backs out of the AC fallback.
272
+ * Only fetched when the inverter-total fallback will actually be used — the
273
+ * correction is irrelevant for the MPPT-string path — so a device with working
274
+ * strings never pays the extra battery read. Prefers the Model 160
275
+ * `StCha`/`StDisCha` strings, falling back to Model 124/802. `undefined` when
276
+ * no correction is needed or no live battery source exists.
277
+ */
278
+ private fetchAcCorrectionBatteryPowerW;
279
+ /**
280
+ * Assemble a {@link SunspecInverterReading} from an already-read register set.
281
+ * Pure (no I/O, no side effects) so both `getInverterReading` and the polling
282
+ * `readData` produce identical readings from a single shared code path.
283
+ */
284
+ private buildInverterReading;
242
285
  /**
243
286
  * PV production in Watt, sourced according to the configured `pvPowerSource`:
244
287
  *
@@ -255,19 +298,38 @@ export declare class SunspecInverter extends BaseSunspecDevice {
255
298
  * Both inverter-total steps require a strictly positive value, so NOT_IMPLEMENTED
256
299
  * DCW (decodes to 0) falls through to AC, and a negative AC reading (e.g. a hybrid
257
300
  * importing from grid) falls through to 0 rather than reporting negative production.
258
- * Edge case: in Auto/Inverter a hybrid discharging its battery while its MPPT is
259
- * unreadable reports AC (incl. battery) rather than 0 — acceptable, and strictly
260
- * better than reporting 0.
301
+ *
302
+ * The AC fallback backs out battery power via `batteryPowerW` (signed: positive =
303
+ * charging, negative = discharging). A hybrid's AC total is PV − charge + discharge,
304
+ * so real PV = AC + batteryPowerW. Without this, a battery discharging at night while
305
+ * the MPPT is unreadable would be reported as phantom PV production. `batteryPowerW`
306
+ * is undefined when no live battery source is available, in which case AC is used
307
+ * uncorrected (still better than reporting 0).
308
+ *
309
+ * The returned `pvPowerW` is always clamped to ≥ 0 — PV production is non-negative by
310
+ * definition and must never surface as a negative value on the data bus.
261
311
  */
262
- protected selectPvPowerW(dcStrings: EnyoDataBusInverterValuesV1String[], inverterData: SunspecInverterData): {
263
- pvPowerW: number;
264
- source: string;
265
- };
312
+ protected selectPvPowerW(dcStrings: EnyoDataBusInverterValuesV1String[], inverterData: SunspecInverterData, batteryPowerW?: number): SunspecPvPower;
266
313
  /**
267
- * Inverter total PV power from Model 101: DCW when strictly positive, else AC when
268
- * strictly positive, else 0. See {@link selectPvPowerW} for why positivity matters.
314
+ * Whether {@link selectPvPowerW} will source PV from the inverter total (rather than
315
+ * the summed MPPT strings) for the given string count. Mppt never does; Inverter
316
+ * always does; Auto does only when there are no strings. Exposed so `readData` can
317
+ * decide up front whether it needs to fetch battery power for the AC correction.
318
+ */
319
+ private wouldUseInverterTotal;
320
+ /**
321
+ * Inverter total PV power from Model 101: DCW when strictly positive, else AC (with
322
+ * battery power backed out) when the result is strictly positive, else 0. See
323
+ * {@link selectPvPowerW} for the battery correction and why positivity matters.
269
324
  */
270
325
  private inverterTotalPvPowerW;
326
+ /**
327
+ * Summed per-string MPPT DC power (Model 160), battery strings already filtered
328
+ * out by {@link mapMPPTToStrings}. finiteOr per-string so one NaN/Infinity powerW
329
+ * cannot poison the sum; clamped to ≥ 0. Feeds both the MPPT-source selection and
330
+ * the always-reported {@link SunspecInverterReading.inverterPowerWDcStrings}.
331
+ */
332
+ private sumDcStringsW;
271
333
  /**
272
334
  * Map MPPT data to DC string structure for data bus
273
335
  * Filters out battery-related strings (StCha 3, StDisCha 4)
@@ -346,6 +408,20 @@ export declare function detectFeaturesFromRegisters(batteryData: SunspecBatteryD
346
408
  * Exported as a free function so the preference logic can be unit-tested
347
409
  * without the full `SunspecBattery` scaffold.
348
410
  */
411
+ /**
412
+ * Sum battery charge/discharge power from Model 160 MPPT strings.
413
+ *
414
+ * - `StCha 3` → charging power (added, positive)
415
+ * - `StDisCha 4` → discharging power (subtracted)
416
+ *
417
+ * The result follows the battery-power sign convention used across this file:
418
+ * positive = charging, negative = discharging. Returns `undefined` when neither
419
+ * battery string is present, so callers can fall through to another source.
420
+ *
421
+ * Exported as a free function so it can be unit-tested and reused by both the
422
+ * SunspecBattery live-power path and the SunspecInverter AC-fallback correction.
423
+ */
424
+ export declare function sumMpptBatteryPowerW(mpptDataList: SunspecMPPTData[]): number | undefined;
349
425
  export declare function selectLiveBatteryPowerW(mpptBatteryPowerW: number | undefined, batteryData: SunspecBatteryData | null): number | undefined;
350
426
  export declare function filterFeaturesByCalibrationResult(detected: EnyoBatteryFeature[], result: CalibrationResult | undefined, controllable: readonly EnyoBatteryFeature[]): EnyoBatteryFeature[];
351
427
  /**
@@ -411,6 +487,25 @@ export declare class SunspecBattery extends BaseSunspecDevice {
411
487
  * Map SunSpec battery charge state to Enyo battery state
412
488
  */
413
489
  private mapToEnyoBatteryState;
490
+ /**
491
+ * Read a decoupled snapshot of the battery's live telemetry — state of charge,
492
+ * signed power (positive = charging, negative = discharging) and charge state —
493
+ * WITHOUT constructing or sending any data-bus message. The consumer decides
494
+ * whether and how to publish it.
495
+ *
496
+ * This is the clean read primitive the SDK's own polling (`readData`) is built
497
+ * on, so a direct caller gets exactly the same numbers the bus would carry.
498
+ * Returns `null` when not connected (after a reconnect attempt) or when the
499
+ * device exposes no readable battery model.
500
+ */
501
+ getBatteryReading(): Promise<SunspecBatteryReading | null>;
502
+ /**
503
+ * Assemble a {@link SunspecBatteryReading} from an already-read register set.
504
+ * Pure (no I/O, no side effects) so both `getBatteryReading` and the polling
505
+ * `readData` produce identical readings from a single shared code path. See
506
+ * {@link selectLiveBatteryPowerW} for the power source-preference rationale.
507
+ */
508
+ private buildBatteryReading;
414
509
  /**
415
510
  * Update battery data and return data bus messages
416
511
  */
@@ -577,3 +672,4 @@ export declare class SunspecMeter extends BaseSunspecDevice {
577
672
  */
578
673
  readData(clockId: string, resolution: EnyoDataBusMessageResolution): Promise<EnyoDataBusMessage[]>;
579
674
  }
675
+ export {};
@@ -3,7 +3,7 @@
3
3
  * SunSpec block interfaces with block numbers
4
4
  */
5
5
  Object.defineProperty(exports, "__esModule", { value: true });
6
- exports.SUNSPEC_CONTROLLABLE_FEATURES = exports.SunspecMeterCapability = exports.SunspecBatteryFeatureModeKind = exports.SunspecBatteryCapability = exports.SunspecPvPowerSource = exports.SunspecInverterCapability = exports.SunspecStorageMode = exports.SunspecChargeSource = exports.SunspecVArPctMode = exports.SunspecEnableControl = exports.SunspecConnectionControl = exports.SunspecStorageControlMode = exports.SunspecBatteryEvent1 = exports.SunspecBatteryBankState = exports.SunspecBatteryType = exports.SunspecBatteryControlMode = exports.SunspecBatteryChargeState = exports.SunspecInverterOperatingState = exports.SunspecMPPTOperatingState = exports.SUNSPEC_CONNECTION_LOST_CODE = exports.SunspecInverterEvent1 = exports.SunspecModelId = exports.DEFAULT_RETRY_CONFIG = void 0;
6
+ exports.SUNSPEC_CONTROLLABLE_FEATURES = exports.SunspecMeterCapability = exports.SunspecBatteryFeatureModeKind = exports.SunspecBatteryCapability = exports.SunspecPvPowerOrigin = exports.SunspecPvPowerSource = exports.SunspecInverterCapability = exports.SunspecStorageMode = exports.SunspecChargeSource = exports.SunspecVArPctMode = exports.SunspecEnableControl = exports.SunspecConnectionControl = exports.SunspecStorageControlMode = exports.SunspecBatteryEvent1 = exports.SunspecBatteryBankState = exports.SunspecBatteryType = exports.SunspecBatteryControlMode = exports.SunspecBatteryChargeState = exports.SunspecInverterOperatingState = exports.SunspecMPPTOperatingState = exports.SUNSPEC_CONNECTION_LOST_CODE = exports.SunspecInverterEvent1 = exports.SunspecModelId = exports.DEFAULT_RETRY_CONFIG = void 0;
7
7
  const enyo_battery_appliance_js_1 = require("@enyo-energy/energy-app-sdk/dist/types/enyo-battery-appliance.js");
8
8
  exports.DEFAULT_RETRY_CONFIG = {
9
9
  phases: [
@@ -282,6 +282,28 @@ var SunspecPvPowerSource;
282
282
  SunspecPvPowerSource["Mppt"] = "mppt";
283
283
  SunspecPvPowerSource["Inverter"] = "inverter";
284
284
  })(SunspecPvPowerSource || (exports.SunspecPvPowerSource = SunspecPvPowerSource = {}));
285
+ /**
286
+ * The concrete register set an inverter's PV power reading was actually derived
287
+ * from — the *resolved* origin, as opposed to {@link SunspecPvPowerSource} which
288
+ * is the *configured* preference. Returned on {@link SunspecInverterReading} so a
289
+ * consumer can see which telemetry produced the number.
290
+ *
291
+ * - `MpptStrings`: summed per-string DC power from Model 160 (battery strings
292
+ * `StCha 3` / `StDisCha 4` excluded). Already pure PV — never battery-adjusted.
293
+ * - `InverterDc`: the inverter's total DC power (Model 101 `DCW`). Pure PV — never
294
+ * battery-adjusted.
295
+ * - `InverterAc`: the inverter's total AC power (Model 101 `W`). On a hybrid this
296
+ * includes battery flow, so `inverterPowerW` backs it out
297
+ * (PV = AC + batteryPowerW) while `inverterPowerWRaw` keeps the uncorrected AC value.
298
+ * - `None`: no strictly-positive inverter total was available; `inverterPowerW` is 0.
299
+ */
300
+ var SunspecPvPowerOrigin;
301
+ (function (SunspecPvPowerOrigin) {
302
+ SunspecPvPowerOrigin["MpptStrings"] = "mppt-strings";
303
+ SunspecPvPowerOrigin["InverterDc"] = "inverter-dc";
304
+ SunspecPvPowerOrigin["InverterAc"] = "inverter-ac";
305
+ SunspecPvPowerOrigin["None"] = "none";
306
+ })(SunspecPvPowerOrigin || (exports.SunspecPvPowerOrigin = SunspecPvPowerOrigin = {}));
285
307
  var SunspecBatteryCapability;
286
308
  (function (SunspecBatteryCapability) {
287
309
  SunspecBatteryCapability["GridCharging"] = "grid-charging";