@enyo-energy/sunspec-sdk 0.0.96 → 0.0.97
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/dist/cjs/sunspec-devices.cjs +80 -27
- package/dist/cjs/sunspec-devices.d.cts +35 -6
- package/dist/cjs/version.cjs +1 -1
- package/dist/cjs/version.d.cts +1 -1
- package/dist/sunspec-devices.d.ts +35 -6
- package/dist/sunspec-devices.js +79 -27
- package/dist/version.d.ts +1 -1
- package/dist/version.js +1 -1
- package/package.json +1 -1
|
@@ -2,6 +2,7 @@
|
|
|
2
2
|
Object.defineProperty(exports, "__esModule", { value: true });
|
|
3
3
|
exports.SunspecMeter = exports.SunspecBattery = exports.SunspecInverter = exports.BaseSunspecDevice = void 0;
|
|
4
4
|
exports.detectFeaturesFromRegisters = detectFeaturesFromRegisters;
|
|
5
|
+
exports.sumMpptBatteryPowerW = sumMpptBatteryPowerW;
|
|
5
6
|
exports.selectLiveBatteryPowerW = selectLiveBatteryPowerW;
|
|
6
7
|
exports.filterFeaturesByCalibrationResult = filterFeaturesByCalibrationResult;
|
|
7
8
|
const sunspec_interfaces_js_1 = require("./sunspec-interfaces.cjs");
|
|
@@ -496,7 +497,20 @@ class SunspecInverter extends BaseSunspecDevice {
|
|
|
496
497
|
// to Connected. No-op unless this device is still marked offline.
|
|
497
498
|
await this.reassertConnectedIfRecovered();
|
|
498
499
|
if (inverterData) {
|
|
499
|
-
|
|
500
|
+
// When PV is sourced from the inverter total (no usable MPPT strings),
|
|
501
|
+
// the AC fallback includes any battery charge/discharge on a hybrid.
|
|
502
|
+
// Fetch the live battery power (positive = charging, negative =
|
|
503
|
+
// discharging) so selectPvPowerW can back it out — otherwise a battery
|
|
504
|
+
// discharging at night is reported as phantom PV production.
|
|
505
|
+
let batteryPowerW;
|
|
506
|
+
if (this.wouldUseInverterTotal(dcStrings.length)) {
|
|
507
|
+
batteryPowerW = sumMpptBatteryPowerW(mpptDataList);
|
|
508
|
+
if (batteryPowerW === undefined) {
|
|
509
|
+
const batteryData = await this.sunspecClient.readBatteryData(this.unitId);
|
|
510
|
+
batteryPowerW = selectLiveBatteryPowerW(undefined, batteryData);
|
|
511
|
+
}
|
|
512
|
+
}
|
|
513
|
+
const { pvPowerW, source: pvPowerSource } = this.selectPvPowerW(dcStrings, inverterData, batteryPowerW);
|
|
500
514
|
console.debug(`Got PV Power from ${pvPowerSource}: ${pvPowerW}W`);
|
|
501
515
|
const inverterMessage = {
|
|
502
516
|
id: (0, node_crypto_1.randomUUID)(),
|
|
@@ -834,29 +848,54 @@ class SunspecInverter extends BaseSunspecDevice {
|
|
|
834
848
|
* Both inverter-total steps require a strictly positive value, so NOT_IMPLEMENTED
|
|
835
849
|
* DCW (decodes to 0) falls through to AC, and a negative AC reading (e.g. a hybrid
|
|
836
850
|
* importing from grid) falls through to 0 rather than reporting negative production.
|
|
837
|
-
*
|
|
838
|
-
*
|
|
839
|
-
*
|
|
851
|
+
*
|
|
852
|
+
* The AC fallback backs out battery power via `batteryPowerW` (signed: positive =
|
|
853
|
+
* charging, negative = discharging). A hybrid's AC total is PV − charge + discharge,
|
|
854
|
+
* so real PV = AC + batteryPowerW. Without this, a battery discharging at night while
|
|
855
|
+
* the MPPT is unreadable would be reported as phantom PV production. `batteryPowerW`
|
|
856
|
+
* is undefined when no live battery source is available, in which case AC is used
|
|
857
|
+
* uncorrected (still better than reporting 0).
|
|
858
|
+
*
|
|
859
|
+
* The returned `pvPowerW` is always clamped to ≥ 0 — PV production is non-negative by
|
|
860
|
+
* definition and must never surface as a negative value on the data bus.
|
|
840
861
|
*/
|
|
841
|
-
selectPvPowerW(dcStrings, inverterData) {
|
|
842
|
-
|
|
843
|
-
|
|
844
|
-
|
|
845
|
-
if (useStrings) {
|
|
846
|
-
return { pvPowerW: stringSumW, source: 'DC strings' };
|
|
862
|
+
selectPvPowerW(dcStrings, inverterData, batteryPowerW) {
|
|
863
|
+
if (!this.wouldUseInverterTotal(dcStrings.length)) {
|
|
864
|
+
const stringSumW = dcStrings.reduce((sum, s) => sum + (s.powerW || 0), 0);
|
|
865
|
+
return { pvPowerW: Math.max(0, stringSumW), source: 'DC strings' };
|
|
847
866
|
}
|
|
848
|
-
return this.inverterTotalPvPowerW(inverterData);
|
|
867
|
+
return this.inverterTotalPvPowerW(inverterData, batteryPowerW);
|
|
868
|
+
}
|
|
869
|
+
/**
|
|
870
|
+
* Whether {@link selectPvPowerW} will source PV from the inverter total (rather than
|
|
871
|
+
* the summed MPPT strings) for the given string count. Mppt never does; Inverter
|
|
872
|
+
* always does; Auto does only when there are no strings. Exposed so `readData` can
|
|
873
|
+
* decide up front whether it needs to fetch battery power for the AC correction.
|
|
874
|
+
*/
|
|
875
|
+
wouldUseInverterTotal(dcStringCount) {
|
|
876
|
+
if (this.pvPowerSource === sunspec_interfaces_js_1.SunspecPvPowerSource.Mppt)
|
|
877
|
+
return false;
|
|
878
|
+
if (this.pvPowerSource === sunspec_interfaces_js_1.SunspecPvPowerSource.Inverter)
|
|
879
|
+
return true;
|
|
880
|
+
return dcStringCount === 0; // Auto
|
|
849
881
|
}
|
|
850
882
|
/**
|
|
851
|
-
* Inverter total PV power from Model 101: DCW when strictly positive, else AC
|
|
852
|
-
* strictly positive, else 0. See
|
|
883
|
+
* Inverter total PV power from Model 101: DCW when strictly positive, else AC (with
|
|
884
|
+
* battery power backed out) when the result is strictly positive, else 0. See
|
|
885
|
+
* {@link selectPvPowerW} for the battery correction and why positivity matters.
|
|
853
886
|
*/
|
|
854
|
-
inverterTotalPvPowerW(inverterData) {
|
|
887
|
+
inverterTotalPvPowerW(inverterData, batteryPowerW) {
|
|
855
888
|
if (typeof inverterData.dcPower === 'number' && inverterData.dcPower > 0) {
|
|
856
889
|
return { pvPowerW: inverterData.dcPower, source: 'DC power (Model 101)' };
|
|
857
890
|
}
|
|
858
891
|
if (typeof inverterData.acPower === 'number' && inverterData.acPower > 0) {
|
|
859
|
-
|
|
892
|
+
// AC = PV − charge + discharge on a hybrid; batteryPowerW is signed
|
|
893
|
+
// (positive = charging, negative = discharging), so PV = AC + batteryPowerW.
|
|
894
|
+
const correctedW = inverterData.acPower + (batteryPowerW ?? 0);
|
|
895
|
+
if (correctedW > 0) {
|
|
896
|
+
return { pvPowerW: correctedW, source: 'AC power (Model 101)' };
|
|
897
|
+
}
|
|
898
|
+
return { pvPowerW: 0, source: 'none' };
|
|
860
899
|
}
|
|
861
900
|
return { pvPowerW: 0, source: 'none' };
|
|
862
901
|
}
|
|
@@ -1089,6 +1128,31 @@ function detectFeaturesFromRegisters(batteryData) {
|
|
|
1089
1128
|
* Exported as a free function so the preference logic can be unit-tested
|
|
1090
1129
|
* without the full `SunspecBattery` scaffold.
|
|
1091
1130
|
*/
|
|
1131
|
+
/**
|
|
1132
|
+
* Sum battery charge/discharge power from Model 160 MPPT strings.
|
|
1133
|
+
*
|
|
1134
|
+
* - `StCha 3` → charging power (added, positive)
|
|
1135
|
+
* - `StDisCha 4` → discharging power (subtracted)
|
|
1136
|
+
*
|
|
1137
|
+
* The result follows the battery-power sign convention used across this file:
|
|
1138
|
+
* positive = charging, negative = discharging. Returns `undefined` when neither
|
|
1139
|
+
* battery string is present, so callers can fall through to another source.
|
|
1140
|
+
*
|
|
1141
|
+
* Exported as a free function so it can be unit-tested and reused by both the
|
|
1142
|
+
* SunspecBattery live-power path and the SunspecInverter AC-fallback correction.
|
|
1143
|
+
*/
|
|
1144
|
+
function sumMpptBatteryPowerW(mpptDataList) {
|
|
1145
|
+
let batteryPowerW;
|
|
1146
|
+
for (const mppt of mpptDataList) {
|
|
1147
|
+
if (mppt.stringId === 'StCha 3' && mppt.dcPower !== undefined) {
|
|
1148
|
+
batteryPowerW = (batteryPowerW ?? 0) + mppt.dcPower;
|
|
1149
|
+
}
|
|
1150
|
+
else if (mppt.stringId === 'StDisCha 4' && mppt.dcPower !== undefined) {
|
|
1151
|
+
batteryPowerW = (batteryPowerW ?? 0) - mppt.dcPower;
|
|
1152
|
+
}
|
|
1153
|
+
}
|
|
1154
|
+
return batteryPowerW;
|
|
1155
|
+
}
|
|
1092
1156
|
function selectLiveBatteryPowerW(mpptBatteryPowerW, batteryData) {
|
|
1093
1157
|
if (mpptBatteryPowerW !== undefined) {
|
|
1094
1158
|
return mpptBatteryPowerW;
|
|
@@ -1428,18 +1492,7 @@ class SunspecBattery extends BaseSunspecDevice {
|
|
|
1428
1492
|
* StDisCha 4: Battery discharging power (negative)
|
|
1429
1493
|
*/
|
|
1430
1494
|
extractBatteryPowerFromMPPT(mpptDataList) {
|
|
1431
|
-
|
|
1432
|
-
mpptDataList.forEach((mppt) => {
|
|
1433
|
-
if (mppt.stringId === 'StCha 3' && mppt.dcPower !== undefined) {
|
|
1434
|
-
// Charging power is positive
|
|
1435
|
-
batteryPowerW = (batteryPowerW || 0) + mppt.dcPower;
|
|
1436
|
-
}
|
|
1437
|
-
else if (mppt.stringId === 'StDisCha 4' && mppt.dcPower !== undefined) {
|
|
1438
|
-
// Discharging power is negative
|
|
1439
|
-
batteryPowerW = (batteryPowerW || 0) - mppt.dcPower;
|
|
1440
|
-
}
|
|
1441
|
-
});
|
|
1442
|
-
return batteryPowerW;
|
|
1495
|
+
return sumMpptBatteryPowerW(mpptDataList);
|
|
1443
1496
|
}
|
|
1444
1497
|
/**
|
|
1445
1498
|
* Determine battery state from MPPT strings
|
|
@@ -255,17 +255,32 @@ export declare class SunspecInverter extends BaseSunspecDevice {
|
|
|
255
255
|
* Both inverter-total steps require a strictly positive value, so NOT_IMPLEMENTED
|
|
256
256
|
* DCW (decodes to 0) falls through to AC, and a negative AC reading (e.g. a hybrid
|
|
257
257
|
* importing from grid) falls through to 0 rather than reporting negative production.
|
|
258
|
-
*
|
|
259
|
-
*
|
|
260
|
-
*
|
|
258
|
+
*
|
|
259
|
+
* The AC fallback backs out battery power via `batteryPowerW` (signed: positive =
|
|
260
|
+
* charging, negative = discharging). A hybrid's AC total is PV − charge + discharge,
|
|
261
|
+
* so real PV = AC + batteryPowerW. Without this, a battery discharging at night while
|
|
262
|
+
* the MPPT is unreadable would be reported as phantom PV production. `batteryPowerW`
|
|
263
|
+
* is undefined when no live battery source is available, in which case AC is used
|
|
264
|
+
* uncorrected (still better than reporting 0).
|
|
265
|
+
*
|
|
266
|
+
* The returned `pvPowerW` is always clamped to ≥ 0 — PV production is non-negative by
|
|
267
|
+
* definition and must never surface as a negative value on the data bus.
|
|
261
268
|
*/
|
|
262
|
-
protected selectPvPowerW(dcStrings: EnyoDataBusInverterValuesV1String[], inverterData: SunspecInverterData): {
|
|
269
|
+
protected selectPvPowerW(dcStrings: EnyoDataBusInverterValuesV1String[], inverterData: SunspecInverterData, batteryPowerW?: number): {
|
|
263
270
|
pvPowerW: number;
|
|
264
271
|
source: string;
|
|
265
272
|
};
|
|
266
273
|
/**
|
|
267
|
-
*
|
|
268
|
-
*
|
|
274
|
+
* Whether {@link selectPvPowerW} will source PV from the inverter total (rather than
|
|
275
|
+
* the summed MPPT strings) for the given string count. Mppt never does; Inverter
|
|
276
|
+
* always does; Auto does only when there are no strings. Exposed so `readData` can
|
|
277
|
+
* decide up front whether it needs to fetch battery power for the AC correction.
|
|
278
|
+
*/
|
|
279
|
+
private wouldUseInverterTotal;
|
|
280
|
+
/**
|
|
281
|
+
* Inverter total PV power from Model 101: DCW when strictly positive, else AC (with
|
|
282
|
+
* battery power backed out) when the result is strictly positive, else 0. See
|
|
283
|
+
* {@link selectPvPowerW} for the battery correction and why positivity matters.
|
|
269
284
|
*/
|
|
270
285
|
private inverterTotalPvPowerW;
|
|
271
286
|
/**
|
|
@@ -346,6 +361,20 @@ export declare function detectFeaturesFromRegisters(batteryData: SunspecBatteryD
|
|
|
346
361
|
* Exported as a free function so the preference logic can be unit-tested
|
|
347
362
|
* without the full `SunspecBattery` scaffold.
|
|
348
363
|
*/
|
|
364
|
+
/**
|
|
365
|
+
* Sum battery charge/discharge power from Model 160 MPPT strings.
|
|
366
|
+
*
|
|
367
|
+
* - `StCha 3` → charging power (added, positive)
|
|
368
|
+
* - `StDisCha 4` → discharging power (subtracted)
|
|
369
|
+
*
|
|
370
|
+
* The result follows the battery-power sign convention used across this file:
|
|
371
|
+
* positive = charging, negative = discharging. Returns `undefined` when neither
|
|
372
|
+
* battery string is present, so callers can fall through to another source.
|
|
373
|
+
*
|
|
374
|
+
* Exported as a free function so it can be unit-tested and reused by both the
|
|
375
|
+
* SunspecBattery live-power path and the SunspecInverter AC-fallback correction.
|
|
376
|
+
*/
|
|
377
|
+
export declare function sumMpptBatteryPowerW(mpptDataList: SunspecMPPTData[]): number | undefined;
|
|
349
378
|
export declare function selectLiveBatteryPowerW(mpptBatteryPowerW: number | undefined, batteryData: SunspecBatteryData | null): number | undefined;
|
|
350
379
|
export declare function filterFeaturesByCalibrationResult(detected: EnyoBatteryFeature[], result: CalibrationResult | undefined, controllable: readonly EnyoBatteryFeature[]): EnyoBatteryFeature[];
|
|
351
380
|
/**
|
package/dist/cjs/version.cjs
CHANGED
|
@@ -9,7 +9,7 @@ exports.getSdkVersion = getSdkVersion;
|
|
|
9
9
|
/**
|
|
10
10
|
* Current version of the enyo Energy App SDK.
|
|
11
11
|
*/
|
|
12
|
-
exports.SDK_VERSION = '0.0.
|
|
12
|
+
exports.SDK_VERSION = '0.0.97';
|
|
13
13
|
/**
|
|
14
14
|
* Gets the current SDK version.
|
|
15
15
|
* @returns The semantic version string of the SDK
|
package/dist/cjs/version.d.cts
CHANGED
|
@@ -255,17 +255,32 @@ export declare class SunspecInverter extends BaseSunspecDevice {
|
|
|
255
255
|
* Both inverter-total steps require a strictly positive value, so NOT_IMPLEMENTED
|
|
256
256
|
* DCW (decodes to 0) falls through to AC, and a negative AC reading (e.g. a hybrid
|
|
257
257
|
* importing from grid) falls through to 0 rather than reporting negative production.
|
|
258
|
-
*
|
|
259
|
-
*
|
|
260
|
-
*
|
|
258
|
+
*
|
|
259
|
+
* The AC fallback backs out battery power via `batteryPowerW` (signed: positive =
|
|
260
|
+
* charging, negative = discharging). A hybrid's AC total is PV − charge + discharge,
|
|
261
|
+
* so real PV = AC + batteryPowerW. Without this, a battery discharging at night while
|
|
262
|
+
* the MPPT is unreadable would be reported as phantom PV production. `batteryPowerW`
|
|
263
|
+
* is undefined when no live battery source is available, in which case AC is used
|
|
264
|
+
* uncorrected (still better than reporting 0).
|
|
265
|
+
*
|
|
266
|
+
* The returned `pvPowerW` is always clamped to ≥ 0 — PV production is non-negative by
|
|
267
|
+
* definition and must never surface as a negative value on the data bus.
|
|
261
268
|
*/
|
|
262
|
-
protected selectPvPowerW(dcStrings: EnyoDataBusInverterValuesV1String[], inverterData: SunspecInverterData): {
|
|
269
|
+
protected selectPvPowerW(dcStrings: EnyoDataBusInverterValuesV1String[], inverterData: SunspecInverterData, batteryPowerW?: number): {
|
|
263
270
|
pvPowerW: number;
|
|
264
271
|
source: string;
|
|
265
272
|
};
|
|
266
273
|
/**
|
|
267
|
-
*
|
|
268
|
-
*
|
|
274
|
+
* Whether {@link selectPvPowerW} will source PV from the inverter total (rather than
|
|
275
|
+
* the summed MPPT strings) for the given string count. Mppt never does; Inverter
|
|
276
|
+
* always does; Auto does only when there are no strings. Exposed so `readData` can
|
|
277
|
+
* decide up front whether it needs to fetch battery power for the AC correction.
|
|
278
|
+
*/
|
|
279
|
+
private wouldUseInverterTotal;
|
|
280
|
+
/**
|
|
281
|
+
* Inverter total PV power from Model 101: DCW when strictly positive, else AC (with
|
|
282
|
+
* battery power backed out) when the result is strictly positive, else 0. See
|
|
283
|
+
* {@link selectPvPowerW} for the battery correction and why positivity matters.
|
|
269
284
|
*/
|
|
270
285
|
private inverterTotalPvPowerW;
|
|
271
286
|
/**
|
|
@@ -346,6 +361,20 @@ export declare function detectFeaturesFromRegisters(batteryData: SunspecBatteryD
|
|
|
346
361
|
* Exported as a free function so the preference logic can be unit-tested
|
|
347
362
|
* without the full `SunspecBattery` scaffold.
|
|
348
363
|
*/
|
|
364
|
+
/**
|
|
365
|
+
* Sum battery charge/discharge power from Model 160 MPPT strings.
|
|
366
|
+
*
|
|
367
|
+
* - `StCha 3` → charging power (added, positive)
|
|
368
|
+
* - `StDisCha 4` → discharging power (subtracted)
|
|
369
|
+
*
|
|
370
|
+
* The result follows the battery-power sign convention used across this file:
|
|
371
|
+
* positive = charging, negative = discharging. Returns `undefined` when neither
|
|
372
|
+
* battery string is present, so callers can fall through to another source.
|
|
373
|
+
*
|
|
374
|
+
* Exported as a free function so it can be unit-tested and reused by both the
|
|
375
|
+
* SunspecBattery live-power path and the SunspecInverter AC-fallback correction.
|
|
376
|
+
*/
|
|
377
|
+
export declare function sumMpptBatteryPowerW(mpptDataList: SunspecMPPTData[]): number | undefined;
|
|
349
378
|
export declare function selectLiveBatteryPowerW(mpptBatteryPowerW: number | undefined, batteryData: SunspecBatteryData | null): number | undefined;
|
|
350
379
|
export declare function filterFeaturesByCalibrationResult(detected: EnyoBatteryFeature[], result: CalibrationResult | undefined, controllable: readonly EnyoBatteryFeature[]): EnyoBatteryFeature[];
|
|
351
380
|
/**
|
package/dist/sunspec-devices.js
CHANGED
|
@@ -489,7 +489,20 @@ export class SunspecInverter extends BaseSunspecDevice {
|
|
|
489
489
|
// to Connected. No-op unless this device is still marked offline.
|
|
490
490
|
await this.reassertConnectedIfRecovered();
|
|
491
491
|
if (inverterData) {
|
|
492
|
-
|
|
492
|
+
// When PV is sourced from the inverter total (no usable MPPT strings),
|
|
493
|
+
// the AC fallback includes any battery charge/discharge on a hybrid.
|
|
494
|
+
// Fetch the live battery power (positive = charging, negative =
|
|
495
|
+
// discharging) so selectPvPowerW can back it out — otherwise a battery
|
|
496
|
+
// discharging at night is reported as phantom PV production.
|
|
497
|
+
let batteryPowerW;
|
|
498
|
+
if (this.wouldUseInverterTotal(dcStrings.length)) {
|
|
499
|
+
batteryPowerW = sumMpptBatteryPowerW(mpptDataList);
|
|
500
|
+
if (batteryPowerW === undefined) {
|
|
501
|
+
const batteryData = await this.sunspecClient.readBatteryData(this.unitId);
|
|
502
|
+
batteryPowerW = selectLiveBatteryPowerW(undefined, batteryData);
|
|
503
|
+
}
|
|
504
|
+
}
|
|
505
|
+
const { pvPowerW, source: pvPowerSource } = this.selectPvPowerW(dcStrings, inverterData, batteryPowerW);
|
|
493
506
|
console.debug(`Got PV Power from ${pvPowerSource}: ${pvPowerW}W`);
|
|
494
507
|
const inverterMessage = {
|
|
495
508
|
id: randomUUID(),
|
|
@@ -827,29 +840,54 @@ export class SunspecInverter extends BaseSunspecDevice {
|
|
|
827
840
|
* Both inverter-total steps require a strictly positive value, so NOT_IMPLEMENTED
|
|
828
841
|
* DCW (decodes to 0) falls through to AC, and a negative AC reading (e.g. a hybrid
|
|
829
842
|
* importing from grid) falls through to 0 rather than reporting negative production.
|
|
830
|
-
*
|
|
831
|
-
*
|
|
832
|
-
*
|
|
843
|
+
*
|
|
844
|
+
* The AC fallback backs out battery power via `batteryPowerW` (signed: positive =
|
|
845
|
+
* charging, negative = discharging). A hybrid's AC total is PV − charge + discharge,
|
|
846
|
+
* so real PV = AC + batteryPowerW. Without this, a battery discharging at night while
|
|
847
|
+
* the MPPT is unreadable would be reported as phantom PV production. `batteryPowerW`
|
|
848
|
+
* is undefined when no live battery source is available, in which case AC is used
|
|
849
|
+
* uncorrected (still better than reporting 0).
|
|
850
|
+
*
|
|
851
|
+
* The returned `pvPowerW` is always clamped to ≥ 0 — PV production is non-negative by
|
|
852
|
+
* definition and must never surface as a negative value on the data bus.
|
|
833
853
|
*/
|
|
834
|
-
selectPvPowerW(dcStrings, inverterData) {
|
|
835
|
-
|
|
836
|
-
|
|
837
|
-
|
|
838
|
-
if (useStrings) {
|
|
839
|
-
return { pvPowerW: stringSumW, source: 'DC strings' };
|
|
854
|
+
selectPvPowerW(dcStrings, inverterData, batteryPowerW) {
|
|
855
|
+
if (!this.wouldUseInverterTotal(dcStrings.length)) {
|
|
856
|
+
const stringSumW = dcStrings.reduce((sum, s) => sum + (s.powerW || 0), 0);
|
|
857
|
+
return { pvPowerW: Math.max(0, stringSumW), source: 'DC strings' };
|
|
840
858
|
}
|
|
841
|
-
return this.inverterTotalPvPowerW(inverterData);
|
|
859
|
+
return this.inverterTotalPvPowerW(inverterData, batteryPowerW);
|
|
860
|
+
}
|
|
861
|
+
/**
|
|
862
|
+
* Whether {@link selectPvPowerW} will source PV from the inverter total (rather than
|
|
863
|
+
* the summed MPPT strings) for the given string count. Mppt never does; Inverter
|
|
864
|
+
* always does; Auto does only when there are no strings. Exposed so `readData` can
|
|
865
|
+
* decide up front whether it needs to fetch battery power for the AC correction.
|
|
866
|
+
*/
|
|
867
|
+
wouldUseInverterTotal(dcStringCount) {
|
|
868
|
+
if (this.pvPowerSource === SunspecPvPowerSource.Mppt)
|
|
869
|
+
return false;
|
|
870
|
+
if (this.pvPowerSource === SunspecPvPowerSource.Inverter)
|
|
871
|
+
return true;
|
|
872
|
+
return dcStringCount === 0; // Auto
|
|
842
873
|
}
|
|
843
874
|
/**
|
|
844
|
-
* Inverter total PV power from Model 101: DCW when strictly positive, else AC
|
|
845
|
-
* strictly positive, else 0. See
|
|
875
|
+
* Inverter total PV power from Model 101: DCW when strictly positive, else AC (with
|
|
876
|
+
* battery power backed out) when the result is strictly positive, else 0. See
|
|
877
|
+
* {@link selectPvPowerW} for the battery correction and why positivity matters.
|
|
846
878
|
*/
|
|
847
|
-
inverterTotalPvPowerW(inverterData) {
|
|
879
|
+
inverterTotalPvPowerW(inverterData, batteryPowerW) {
|
|
848
880
|
if (typeof inverterData.dcPower === 'number' && inverterData.dcPower > 0) {
|
|
849
881
|
return { pvPowerW: inverterData.dcPower, source: 'DC power (Model 101)' };
|
|
850
882
|
}
|
|
851
883
|
if (typeof inverterData.acPower === 'number' && inverterData.acPower > 0) {
|
|
852
|
-
|
|
884
|
+
// AC = PV − charge + discharge on a hybrid; batteryPowerW is signed
|
|
885
|
+
// (positive = charging, negative = discharging), so PV = AC + batteryPowerW.
|
|
886
|
+
const correctedW = inverterData.acPower + (batteryPowerW ?? 0);
|
|
887
|
+
if (correctedW > 0) {
|
|
888
|
+
return { pvPowerW: correctedW, source: 'AC power (Model 101)' };
|
|
889
|
+
}
|
|
890
|
+
return { pvPowerW: 0, source: 'none' };
|
|
853
891
|
}
|
|
854
892
|
return { pvPowerW: 0, source: 'none' };
|
|
855
893
|
}
|
|
@@ -1081,6 +1119,31 @@ export function detectFeaturesFromRegisters(batteryData) {
|
|
|
1081
1119
|
* Exported as a free function so the preference logic can be unit-tested
|
|
1082
1120
|
* without the full `SunspecBattery` scaffold.
|
|
1083
1121
|
*/
|
|
1122
|
+
/**
|
|
1123
|
+
* Sum battery charge/discharge power from Model 160 MPPT strings.
|
|
1124
|
+
*
|
|
1125
|
+
* - `StCha 3` → charging power (added, positive)
|
|
1126
|
+
* - `StDisCha 4` → discharging power (subtracted)
|
|
1127
|
+
*
|
|
1128
|
+
* The result follows the battery-power sign convention used across this file:
|
|
1129
|
+
* positive = charging, negative = discharging. Returns `undefined` when neither
|
|
1130
|
+
* battery string is present, so callers can fall through to another source.
|
|
1131
|
+
*
|
|
1132
|
+
* Exported as a free function so it can be unit-tested and reused by both the
|
|
1133
|
+
* SunspecBattery live-power path and the SunspecInverter AC-fallback correction.
|
|
1134
|
+
*/
|
|
1135
|
+
export function sumMpptBatteryPowerW(mpptDataList) {
|
|
1136
|
+
let batteryPowerW;
|
|
1137
|
+
for (const mppt of mpptDataList) {
|
|
1138
|
+
if (mppt.stringId === 'StCha 3' && mppt.dcPower !== undefined) {
|
|
1139
|
+
batteryPowerW = (batteryPowerW ?? 0) + mppt.dcPower;
|
|
1140
|
+
}
|
|
1141
|
+
else if (mppt.stringId === 'StDisCha 4' && mppt.dcPower !== undefined) {
|
|
1142
|
+
batteryPowerW = (batteryPowerW ?? 0) - mppt.dcPower;
|
|
1143
|
+
}
|
|
1144
|
+
}
|
|
1145
|
+
return batteryPowerW;
|
|
1146
|
+
}
|
|
1084
1147
|
export function selectLiveBatteryPowerW(mpptBatteryPowerW, batteryData) {
|
|
1085
1148
|
if (mpptBatteryPowerW !== undefined) {
|
|
1086
1149
|
return mpptBatteryPowerW;
|
|
@@ -1420,18 +1483,7 @@ export class SunspecBattery extends BaseSunspecDevice {
|
|
|
1420
1483
|
* StDisCha 4: Battery discharging power (negative)
|
|
1421
1484
|
*/
|
|
1422
1485
|
extractBatteryPowerFromMPPT(mpptDataList) {
|
|
1423
|
-
|
|
1424
|
-
mpptDataList.forEach((mppt) => {
|
|
1425
|
-
if (mppt.stringId === 'StCha 3' && mppt.dcPower !== undefined) {
|
|
1426
|
-
// Charging power is positive
|
|
1427
|
-
batteryPowerW = (batteryPowerW || 0) + mppt.dcPower;
|
|
1428
|
-
}
|
|
1429
|
-
else if (mppt.stringId === 'StDisCha 4' && mppt.dcPower !== undefined) {
|
|
1430
|
-
// Discharging power is negative
|
|
1431
|
-
batteryPowerW = (batteryPowerW || 0) - mppt.dcPower;
|
|
1432
|
-
}
|
|
1433
|
-
});
|
|
1434
|
-
return batteryPowerW;
|
|
1486
|
+
return sumMpptBatteryPowerW(mpptDataList);
|
|
1435
1487
|
}
|
|
1436
1488
|
/**
|
|
1437
1489
|
* Determine battery state from MPPT strings
|
package/dist/version.d.ts
CHANGED
package/dist/version.js
CHANGED