@enyo-energy/sunspec-sdk 0.0.95 → 0.0.97
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/dist/cjs/sunspec-devices.cjs +164 -28
- package/dist/cjs/sunspec-devices.d.cts +85 -8
- package/dist/cjs/sunspec-interfaces.d.cts +1 -0
- package/dist/cjs/sunspec-modbus-client.cjs +6 -2
- package/dist/cjs/version.cjs +1 -1
- package/dist/cjs/version.d.cts +1 -1
- package/dist/sunspec-devices.d.ts +85 -8
- package/dist/sunspec-devices.js +163 -28
- package/dist/sunspec-interfaces.d.ts +1 -0
- package/dist/sunspec-modbus-client.js +6 -2
- package/dist/version.d.ts +1 -1
- package/dist/version.js +1 -1
- package/package.json +2 -2
|
@@ -2,6 +2,7 @@
|
|
|
2
2
|
Object.defineProperty(exports, "__esModule", { value: true });
|
|
3
3
|
exports.SunspecMeter = exports.SunspecBattery = exports.SunspecInverter = exports.BaseSunspecDevice = void 0;
|
|
4
4
|
exports.detectFeaturesFromRegisters = detectFeaturesFromRegisters;
|
|
5
|
+
exports.sumMpptBatteryPowerW = sumMpptBatteryPowerW;
|
|
5
6
|
exports.selectLiveBatteryPowerW = selectLiveBatteryPowerW;
|
|
6
7
|
exports.filterFeaturesByCalibrationResult = filterFeaturesByCalibrationResult;
|
|
7
8
|
const sunspec_interfaces_js_1 = require("./sunspec-interfaces.cjs");
|
|
@@ -362,6 +363,13 @@ class SunspecInverter extends BaseSunspecDevice {
|
|
|
362
363
|
// state reads healthy), so we force one re-assert of the current status on
|
|
363
364
|
// the first successful read of each session to converge the core.
|
|
364
365
|
statusReassertedThisSession = false;
|
|
366
|
+
// Last accepted cumulative AC-energy reading (Wh) and how many consecutive
|
|
367
|
+
// polls have reported a corrupt one (a decrease or a ≥½-register-quantum jump
|
|
368
|
+
// — the acc32 16-bit word-boundary artifact). See sanitizeAcEnergyWh.
|
|
369
|
+
lastGoodAcEnergyWh;
|
|
370
|
+
acEnergyDropStreak = 0;
|
|
371
|
+
/** Consecutive corrupt reads that confirm a genuine reset/resync (vs a transient glitch). */
|
|
372
|
+
static AC_ENERGY_RESET_CONFIRM = 3;
|
|
365
373
|
constructor(energyApp, name, networkDevice, sunspecClient, applianceManager, unitId = 1, port = 502, baseAddress = 40000, capabilities = [], retryConfig, appliance, useTls,
|
|
366
374
|
// Where pvPowerW is sourced from — see SunspecPvPowerSource. Defaults to
|
|
367
375
|
// Auto (MPPT strings, then Model 101 DCW/AC fallback). Use Mppt to report
|
|
@@ -489,7 +497,20 @@ class SunspecInverter extends BaseSunspecDevice {
|
|
|
489
497
|
// to Connected. No-op unless this device is still marked offline.
|
|
490
498
|
await this.reassertConnectedIfRecovered();
|
|
491
499
|
if (inverterData) {
|
|
492
|
-
|
|
500
|
+
// When PV is sourced from the inverter total (no usable MPPT strings),
|
|
501
|
+
// the AC fallback includes any battery charge/discharge on a hybrid.
|
|
502
|
+
// Fetch the live battery power (positive = charging, negative =
|
|
503
|
+
// discharging) so selectPvPowerW can back it out — otherwise a battery
|
|
504
|
+
// discharging at night is reported as phantom PV production.
|
|
505
|
+
let batteryPowerW;
|
|
506
|
+
if (this.wouldUseInverterTotal(dcStrings.length)) {
|
|
507
|
+
batteryPowerW = sumMpptBatteryPowerW(mpptDataList);
|
|
508
|
+
if (batteryPowerW === undefined) {
|
|
509
|
+
const batteryData = await this.sunspecClient.readBatteryData(this.unitId);
|
|
510
|
+
batteryPowerW = selectLiveBatteryPowerW(undefined, batteryData);
|
|
511
|
+
}
|
|
512
|
+
}
|
|
513
|
+
const { pvPowerW, source: pvPowerSource } = this.selectPvPowerW(dcStrings, inverterData, batteryPowerW);
|
|
493
514
|
console.debug(`Got PV Power from ${pvPowerSource}: ${pvPowerW}W`);
|
|
494
515
|
const inverterMessage = {
|
|
495
516
|
id: (0, node_crypto_1.randomUUID)(),
|
|
@@ -507,7 +528,7 @@ class SunspecInverter extends BaseSunspecDevice {
|
|
|
507
528
|
voltageL1: inverterData.voltageAN || 0,
|
|
508
529
|
voltageL2: inverterData.voltageBN ?? undefined,
|
|
509
530
|
voltageL3: inverterData.voltageCN ?? undefined,
|
|
510
|
-
meterValueWh: inverterData.acEnergy,
|
|
531
|
+
meterValueWh: this.sanitizeAcEnergyWh(inverterData.acEnergy, inverterData.acEnergyScaleFactor),
|
|
511
532
|
strings: dcStrings
|
|
512
533
|
}
|
|
513
534
|
};
|
|
@@ -533,6 +554,54 @@ class SunspecInverter extends BaseSunspecDevice {
|
|
|
533
554
|
}
|
|
534
555
|
return messages;
|
|
535
556
|
}
|
|
557
|
+
/**
|
|
558
|
+
* Guard the cumulative AC-energy reading before it is published as
|
|
559
|
+
* `meterValueWh`. The SunSpec `WH` register is an `acc32` (high word + low
|
|
560
|
+
* word) × 10^WH_SF; at a low-word rollover / wake-up the words can be
|
|
561
|
+
* mis-combined, so a poll jumps by exactly one 16-bit word
|
|
562
|
+
* (`65536 × 10^WH_SF`) up or down and back — Dirk Wasow's flip-flop of
|
|
563
|
+
* 6,553,600 Wh. A lifetime accumulator is also monotonic non-decreasing.
|
|
564
|
+
*
|
|
565
|
+
* So a reading is corrupt when it either DECREASES or JUMPS UP by ≥ half a
|
|
566
|
+
* register quantum (real per-poll production is orders of magnitude smaller):
|
|
567
|
+
* we republish the last good value rather than emit it (a raw `max-min`
|
|
568
|
+
* downstream would otherwise inflate it into ~a whole register word). A
|
|
569
|
+
* suspect level that persists for `AC_ENERGY_RESET_CONFIRM` consecutive polls
|
|
570
|
+
* is treated as a genuine reset/resync and adopted.
|
|
571
|
+
*
|
|
572
|
+
* Float models (111/112/113) report `WH` as an IEEE-754 float with no acc32
|
|
573
|
+
* word-boundary artifact; they leave `scaleFactor` undefined. For them there
|
|
574
|
+
* is no register quantum, so we enforce monotonicity only (reject decreases)
|
|
575
|
+
* and accept any increase — the ½-quantum upper bound applies to int+SF
|
|
576
|
+
* models (101/103) alone.
|
|
577
|
+
*/
|
|
578
|
+
sanitizeAcEnergyWh(raw, scaleFactor) {
|
|
579
|
+
if (raw == null)
|
|
580
|
+
return undefined;
|
|
581
|
+
if (this.lastGoodAcEnergyWh == null) {
|
|
582
|
+
this.lastGoodAcEnergyWh = raw;
|
|
583
|
+
this.acEnergyDropStreak = 0;
|
|
584
|
+
return raw;
|
|
585
|
+
}
|
|
586
|
+
const halfQuantumWh = scaleFactor != null ? 0.5 * 65536 * Math.pow(10, scaleFactor) : Infinity;
|
|
587
|
+
const delta = raw - this.lastGoodAcEnergyWh;
|
|
588
|
+
const plausible = delta >= 0 && delta < halfQuantumWh;
|
|
589
|
+
if (plausible) {
|
|
590
|
+
this.lastGoodAcEnergyWh = raw;
|
|
591
|
+
this.acEnergyDropStreak = 0;
|
|
592
|
+
return raw;
|
|
593
|
+
}
|
|
594
|
+
// A decrease or a ≥½-quantum jump — the acc32 word-boundary artifact.
|
|
595
|
+
this.acEnergyDropStreak++;
|
|
596
|
+
if (this.acEnergyDropStreak >= SunspecInverter.AC_ENERGY_RESET_CONFIRM) {
|
|
597
|
+
console.warn(`Notify_Devs: ${this.constructor.name} ${this.applianceId}: AC energy resync confirmed (${this.lastGoodAcEnergyWh} -> ${raw} Wh), adopting new baseline`);
|
|
598
|
+
this.lastGoodAcEnergyWh = raw;
|
|
599
|
+
this.acEnergyDropStreak = 0;
|
|
600
|
+
return raw;
|
|
601
|
+
}
|
|
602
|
+
console.warn(`Notify_Devs: ${this.constructor.name} ${this.applianceId}: rejecting corrupt AC energy reading ${raw} Wh (last good ${this.lastGoodAcEnergyWh} Wh, Δ=${delta}), republishing last good`);
|
|
603
|
+
return this.lastGoodAcEnergyWh;
|
|
604
|
+
}
|
|
536
605
|
/**
|
|
537
606
|
* Decode all active error bits from the inverter event registers into
|
|
538
607
|
* `EnyoApplianceErrorCode`s. Override in a subclass to customize the
|
|
@@ -720,6 +789,34 @@ class SunspecInverter extends BaseSunspecDevice {
|
|
|
720
789
|
return null;
|
|
721
790
|
return limitW;
|
|
722
791
|
}
|
|
792
|
+
/**
|
|
793
|
+
* Set the grid-operator power production (feed-in) limit on the inverter.
|
|
794
|
+
*
|
|
795
|
+
* Writes Model 123 `WMaxLimPct` + `WMaxLim_Ena` (as a percentage of the
|
|
796
|
+
* Model 121 `WMax` nameplate). Pass `null` to remove the limit and return
|
|
797
|
+
* the inverter to unthrottled production.
|
|
798
|
+
*
|
|
799
|
+
* The SDK exposes this so a consumer that receives a grid-operator
|
|
800
|
+
* production-limit command (from the data bus or elsewhere) can apply it;
|
|
801
|
+
* subscribing to and reacting to that command is the consumer's job.
|
|
802
|
+
*
|
|
803
|
+
* @param limitW - Maximum production power in Watts, or `null` to remove the limit
|
|
804
|
+
* @returns `true` if the write succeeded, `false` otherwise
|
|
805
|
+
*/
|
|
806
|
+
async setPowerProductionLimit(limitW) {
|
|
807
|
+
return this.sunspecClient.setFeedInLimit(this.unitId, limitW);
|
|
808
|
+
}
|
|
809
|
+
/**
|
|
810
|
+
* Read the currently active grid-operator power production (feed-in) limit
|
|
811
|
+
* from the inverter, in Watts. Returns `null` when no limit is active, the
|
|
812
|
+
* registers cannot be read, or the configured limit is not actually
|
|
813
|
+
* throttling (limit ≥ `WMax`). See {@link computeActiveProductionLimitW}.
|
|
814
|
+
*/
|
|
815
|
+
async getPowerProductionLimit() {
|
|
816
|
+
const settings = await this.sunspecClient.readInverterSettings(this.unitId);
|
|
817
|
+
const controls = await this.sunspecClient.readInverterControls(this.unitId);
|
|
818
|
+
return this.computeActiveProductionLimitW(settings, controls);
|
|
819
|
+
}
|
|
723
820
|
mapOperatingState(state) {
|
|
724
821
|
if (!state)
|
|
725
822
|
return enyo_data_bus_value_js_1.EnyoInverterStateEnum.Off;
|
|
@@ -751,29 +848,54 @@ class SunspecInverter extends BaseSunspecDevice {
|
|
|
751
848
|
* Both inverter-total steps require a strictly positive value, so NOT_IMPLEMENTED
|
|
752
849
|
* DCW (decodes to 0) falls through to AC, and a negative AC reading (e.g. a hybrid
|
|
753
850
|
* importing from grid) falls through to 0 rather than reporting negative production.
|
|
754
|
-
*
|
|
755
|
-
*
|
|
756
|
-
*
|
|
851
|
+
*
|
|
852
|
+
* The AC fallback backs out battery power via `batteryPowerW` (signed: positive =
|
|
853
|
+
* charging, negative = discharging). A hybrid's AC total is PV − charge + discharge,
|
|
854
|
+
* so real PV = AC + batteryPowerW. Without this, a battery discharging at night while
|
|
855
|
+
* the MPPT is unreadable would be reported as phantom PV production. `batteryPowerW`
|
|
856
|
+
* is undefined when no live battery source is available, in which case AC is used
|
|
857
|
+
* uncorrected (still better than reporting 0).
|
|
858
|
+
*
|
|
859
|
+
* The returned `pvPowerW` is always clamped to ≥ 0 — PV production is non-negative by
|
|
860
|
+
* definition and must never surface as a negative value on the data bus.
|
|
757
861
|
*/
|
|
758
|
-
selectPvPowerW(dcStrings, inverterData) {
|
|
759
|
-
|
|
760
|
-
|
|
761
|
-
|
|
762
|
-
if (useStrings) {
|
|
763
|
-
return { pvPowerW: stringSumW, source: 'DC strings' };
|
|
862
|
+
selectPvPowerW(dcStrings, inverterData, batteryPowerW) {
|
|
863
|
+
if (!this.wouldUseInverterTotal(dcStrings.length)) {
|
|
864
|
+
const stringSumW = dcStrings.reduce((sum, s) => sum + (s.powerW || 0), 0);
|
|
865
|
+
return { pvPowerW: Math.max(0, stringSumW), source: 'DC strings' };
|
|
764
866
|
}
|
|
765
|
-
return this.inverterTotalPvPowerW(inverterData);
|
|
867
|
+
return this.inverterTotalPvPowerW(inverterData, batteryPowerW);
|
|
766
868
|
}
|
|
767
869
|
/**
|
|
768
|
-
*
|
|
769
|
-
*
|
|
870
|
+
* Whether {@link selectPvPowerW} will source PV from the inverter total (rather than
|
|
871
|
+
* the summed MPPT strings) for the given string count. Mppt never does; Inverter
|
|
872
|
+
* always does; Auto does only when there are no strings. Exposed so `readData` can
|
|
873
|
+
* decide up front whether it needs to fetch battery power for the AC correction.
|
|
770
874
|
*/
|
|
771
|
-
|
|
875
|
+
wouldUseInverterTotal(dcStringCount) {
|
|
876
|
+
if (this.pvPowerSource === sunspec_interfaces_js_1.SunspecPvPowerSource.Mppt)
|
|
877
|
+
return false;
|
|
878
|
+
if (this.pvPowerSource === sunspec_interfaces_js_1.SunspecPvPowerSource.Inverter)
|
|
879
|
+
return true;
|
|
880
|
+
return dcStringCount === 0; // Auto
|
|
881
|
+
}
|
|
882
|
+
/**
|
|
883
|
+
* Inverter total PV power from Model 101: DCW when strictly positive, else AC (with
|
|
884
|
+
* battery power backed out) when the result is strictly positive, else 0. See
|
|
885
|
+
* {@link selectPvPowerW} for the battery correction and why positivity matters.
|
|
886
|
+
*/
|
|
887
|
+
inverterTotalPvPowerW(inverterData, batteryPowerW) {
|
|
772
888
|
if (typeof inverterData.dcPower === 'number' && inverterData.dcPower > 0) {
|
|
773
889
|
return { pvPowerW: inverterData.dcPower, source: 'DC power (Model 101)' };
|
|
774
890
|
}
|
|
775
891
|
if (typeof inverterData.acPower === 'number' && inverterData.acPower > 0) {
|
|
776
|
-
|
|
892
|
+
// AC = PV − charge + discharge on a hybrid; batteryPowerW is signed
|
|
893
|
+
// (positive = charging, negative = discharging), so PV = AC + batteryPowerW.
|
|
894
|
+
const correctedW = inverterData.acPower + (batteryPowerW ?? 0);
|
|
895
|
+
if (correctedW > 0) {
|
|
896
|
+
return { pvPowerW: correctedW, source: 'AC power (Model 101)' };
|
|
897
|
+
}
|
|
898
|
+
return { pvPowerW: 0, source: 'none' };
|
|
777
899
|
}
|
|
778
900
|
return { pvPowerW: 0, source: 'none' };
|
|
779
901
|
}
|
|
@@ -1006,6 +1128,31 @@ function detectFeaturesFromRegisters(batteryData) {
|
|
|
1006
1128
|
* Exported as a free function so the preference logic can be unit-tested
|
|
1007
1129
|
* without the full `SunspecBattery` scaffold.
|
|
1008
1130
|
*/
|
|
1131
|
+
/**
|
|
1132
|
+
* Sum battery charge/discharge power from Model 160 MPPT strings.
|
|
1133
|
+
*
|
|
1134
|
+
* - `StCha 3` → charging power (added, positive)
|
|
1135
|
+
* - `StDisCha 4` → discharging power (subtracted)
|
|
1136
|
+
*
|
|
1137
|
+
* The result follows the battery-power sign convention used across this file:
|
|
1138
|
+
* positive = charging, negative = discharging. Returns `undefined` when neither
|
|
1139
|
+
* battery string is present, so callers can fall through to another source.
|
|
1140
|
+
*
|
|
1141
|
+
* Exported as a free function so it can be unit-tested and reused by both the
|
|
1142
|
+
* SunspecBattery live-power path and the SunspecInverter AC-fallback correction.
|
|
1143
|
+
*/
|
|
1144
|
+
function sumMpptBatteryPowerW(mpptDataList) {
|
|
1145
|
+
let batteryPowerW;
|
|
1146
|
+
for (const mppt of mpptDataList) {
|
|
1147
|
+
if (mppt.stringId === 'StCha 3' && mppt.dcPower !== undefined) {
|
|
1148
|
+
batteryPowerW = (batteryPowerW ?? 0) + mppt.dcPower;
|
|
1149
|
+
}
|
|
1150
|
+
else if (mppt.stringId === 'StDisCha 4' && mppt.dcPower !== undefined) {
|
|
1151
|
+
batteryPowerW = (batteryPowerW ?? 0) - mppt.dcPower;
|
|
1152
|
+
}
|
|
1153
|
+
}
|
|
1154
|
+
return batteryPowerW;
|
|
1155
|
+
}
|
|
1009
1156
|
function selectLiveBatteryPowerW(mpptBatteryPowerW, batteryData) {
|
|
1010
1157
|
if (mpptBatteryPowerW !== undefined) {
|
|
1011
1158
|
return mpptBatteryPowerW;
|
|
@@ -1345,18 +1492,7 @@ class SunspecBattery extends BaseSunspecDevice {
|
|
|
1345
1492
|
* StDisCha 4: Battery discharging power (negative)
|
|
1346
1493
|
*/
|
|
1347
1494
|
extractBatteryPowerFromMPPT(mpptDataList) {
|
|
1348
|
-
|
|
1349
|
-
mpptDataList.forEach((mppt) => {
|
|
1350
|
-
if (mppt.stringId === 'StCha 3' && mppt.dcPower !== undefined) {
|
|
1351
|
-
// Charging power is positive
|
|
1352
|
-
batteryPowerW = (batteryPowerW || 0) + mppt.dcPower;
|
|
1353
|
-
}
|
|
1354
|
-
else if (mppt.stringId === 'StDisCha 4' && mppt.dcPower !== undefined) {
|
|
1355
|
-
// Discharging power is negative
|
|
1356
|
-
batteryPowerW = (batteryPowerW || 0) - mppt.dcPower;
|
|
1357
|
-
}
|
|
1358
|
-
});
|
|
1359
|
-
return batteryPowerW;
|
|
1495
|
+
return sumMpptBatteryPowerW(mpptDataList);
|
|
1360
1496
|
}
|
|
1361
1497
|
/**
|
|
1362
1498
|
* Determine battery state from MPPT strings
|
|
@@ -142,10 +142,36 @@ export declare class SunspecInverter extends BaseSunspecDevice {
|
|
|
142
142
|
private errorState;
|
|
143
143
|
private snapshotService?;
|
|
144
144
|
private statusReassertedThisSession;
|
|
145
|
+
private lastGoodAcEnergyWh?;
|
|
146
|
+
private acEnergyDropStreak;
|
|
147
|
+
/** Consecutive corrupt reads that confirm a genuine reset/resync (vs a transient glitch). */
|
|
148
|
+
private static readonly AC_ENERGY_RESET_CONFIRM;
|
|
145
149
|
constructor(energyApp: EnergyApp, name: EnyoApplianceName[], networkDevice: EnyoNetworkDevice, sunspecClient: SunspecModbusClient, applianceManager: ApplianceManager, unitId?: number, port?: number, baseAddress?: number, capabilities?: SunspecInverterCapability[], retryConfig?: IRetryConfig, appliance?: EnyoAppliance, useTls?: boolean, pvPowerSource?: SunspecPvPowerSource);
|
|
146
150
|
connect(): Promise<void>;
|
|
147
151
|
disconnect(): Promise<void>;
|
|
148
|
-
readData(clockId: string, resolution:
|
|
152
|
+
readData(clockId: string, resolution: EnyoDataBusMessageResolution): Promise<EnyoDataBusMessage[]>;
|
|
153
|
+
/**
|
|
154
|
+
* Guard the cumulative AC-energy reading before it is published as
|
|
155
|
+
* `meterValueWh`. The SunSpec `WH` register is an `acc32` (high word + low
|
|
156
|
+
* word) × 10^WH_SF; at a low-word rollover / wake-up the words can be
|
|
157
|
+
* mis-combined, so a poll jumps by exactly one 16-bit word
|
|
158
|
+
* (`65536 × 10^WH_SF`) up or down and back — Dirk Wasow's flip-flop of
|
|
159
|
+
* 6,553,600 Wh. A lifetime accumulator is also monotonic non-decreasing.
|
|
160
|
+
*
|
|
161
|
+
* So a reading is corrupt when it either DECREASES or JUMPS UP by ≥ half a
|
|
162
|
+
* register quantum (real per-poll production is orders of magnitude smaller):
|
|
163
|
+
* we republish the last good value rather than emit it (a raw `max-min`
|
|
164
|
+
* downstream would otherwise inflate it into ~a whole register word). A
|
|
165
|
+
* suspect level that persists for `AC_ENERGY_RESET_CONFIRM` consecutive polls
|
|
166
|
+
* is treated as a genuine reset/resync and adopted.
|
|
167
|
+
*
|
|
168
|
+
* Float models (111/112/113) report `WH` as an IEEE-754 float with no acc32
|
|
169
|
+
* word-boundary artifact; they leave `scaleFactor` undefined. For them there
|
|
170
|
+
* is no register quantum, so we enforce monotonicity only (reject decreases)
|
|
171
|
+
* and accept any increase — the ½-quantum upper bound applies to int+SF
|
|
172
|
+
* models (101/103) alone.
|
|
173
|
+
*/
|
|
174
|
+
private sanitizeAcEnergyWh;
|
|
149
175
|
/**
|
|
150
176
|
* Decode all active error bits from the inverter event registers into
|
|
151
177
|
* `EnyoApplianceErrorCode`s. Override in a subclass to customize the
|
|
@@ -190,6 +216,28 @@ export declare class SunspecInverter extends BaseSunspecDevice {
|
|
|
190
216
|
* returned (not undefined) so the field is cleared on the appliance.
|
|
191
217
|
*/
|
|
192
218
|
private computeActiveProductionLimitW;
|
|
219
|
+
/**
|
|
220
|
+
* Set the grid-operator power production (feed-in) limit on the inverter.
|
|
221
|
+
*
|
|
222
|
+
* Writes Model 123 `WMaxLimPct` + `WMaxLim_Ena` (as a percentage of the
|
|
223
|
+
* Model 121 `WMax` nameplate). Pass `null` to remove the limit and return
|
|
224
|
+
* the inverter to unthrottled production.
|
|
225
|
+
*
|
|
226
|
+
* The SDK exposes this so a consumer that receives a grid-operator
|
|
227
|
+
* production-limit command (from the data bus or elsewhere) can apply it;
|
|
228
|
+
* subscribing to and reacting to that command is the consumer's job.
|
|
229
|
+
*
|
|
230
|
+
* @param limitW - Maximum production power in Watts, or `null` to remove the limit
|
|
231
|
+
* @returns `true` if the write succeeded, `false` otherwise
|
|
232
|
+
*/
|
|
233
|
+
setPowerProductionLimit(limitW: number | null): Promise<boolean>;
|
|
234
|
+
/**
|
|
235
|
+
* Read the currently active grid-operator power production (feed-in) limit
|
|
236
|
+
* from the inverter, in Watts. Returns `null` when no limit is active, the
|
|
237
|
+
* registers cannot be read, or the configured limit is not actually
|
|
238
|
+
* throttling (limit ≥ `WMax`). See {@link computeActiveProductionLimitW}.
|
|
239
|
+
*/
|
|
240
|
+
getPowerProductionLimit(): Promise<number | null>;
|
|
193
241
|
private mapOperatingState;
|
|
194
242
|
/**
|
|
195
243
|
* PV production in Watt, sourced according to the configured `pvPowerSource`:
|
|
@@ -207,17 +255,32 @@ export declare class SunspecInverter extends BaseSunspecDevice {
|
|
|
207
255
|
* Both inverter-total steps require a strictly positive value, so NOT_IMPLEMENTED
|
|
208
256
|
* DCW (decodes to 0) falls through to AC, and a negative AC reading (e.g. a hybrid
|
|
209
257
|
* importing from grid) falls through to 0 rather than reporting negative production.
|
|
210
|
-
*
|
|
211
|
-
*
|
|
212
|
-
*
|
|
258
|
+
*
|
|
259
|
+
* The AC fallback backs out battery power via `batteryPowerW` (signed: positive =
|
|
260
|
+
* charging, negative = discharging). A hybrid's AC total is PV − charge + discharge,
|
|
261
|
+
* so real PV = AC + batteryPowerW. Without this, a battery discharging at night while
|
|
262
|
+
* the MPPT is unreadable would be reported as phantom PV production. `batteryPowerW`
|
|
263
|
+
* is undefined when no live battery source is available, in which case AC is used
|
|
264
|
+
* uncorrected (still better than reporting 0).
|
|
265
|
+
*
|
|
266
|
+
* The returned `pvPowerW` is always clamped to ≥ 0 — PV production is non-negative by
|
|
267
|
+
* definition and must never surface as a negative value on the data bus.
|
|
213
268
|
*/
|
|
214
|
-
protected selectPvPowerW(dcStrings: EnyoDataBusInverterValuesV1String[], inverterData: SunspecInverterData): {
|
|
269
|
+
protected selectPvPowerW(dcStrings: EnyoDataBusInverterValuesV1String[], inverterData: SunspecInverterData, batteryPowerW?: number): {
|
|
215
270
|
pvPowerW: number;
|
|
216
271
|
source: string;
|
|
217
272
|
};
|
|
218
273
|
/**
|
|
219
|
-
*
|
|
220
|
-
*
|
|
274
|
+
* Whether {@link selectPvPowerW} will source PV from the inverter total (rather than
|
|
275
|
+
* the summed MPPT strings) for the given string count. Mppt never does; Inverter
|
|
276
|
+
* always does; Auto does only when there are no strings. Exposed so `readData` can
|
|
277
|
+
* decide up front whether it needs to fetch battery power for the AC correction.
|
|
278
|
+
*/
|
|
279
|
+
private wouldUseInverterTotal;
|
|
280
|
+
/**
|
|
281
|
+
* Inverter total PV power from Model 101: DCW when strictly positive, else AC (with
|
|
282
|
+
* battery power backed out) when the result is strictly positive, else 0. See
|
|
283
|
+
* {@link selectPvPowerW} for the battery correction and why positivity matters.
|
|
221
284
|
*/
|
|
222
285
|
private inverterTotalPvPowerW;
|
|
223
286
|
/**
|
|
@@ -298,6 +361,20 @@ export declare function detectFeaturesFromRegisters(batteryData: SunspecBatteryD
|
|
|
298
361
|
* Exported as a free function so the preference logic can be unit-tested
|
|
299
362
|
* without the full `SunspecBattery` scaffold.
|
|
300
363
|
*/
|
|
364
|
+
/**
|
|
365
|
+
* Sum battery charge/discharge power from Model 160 MPPT strings.
|
|
366
|
+
*
|
|
367
|
+
* - `StCha 3` → charging power (added, positive)
|
|
368
|
+
* - `StDisCha 4` → discharging power (subtracted)
|
|
369
|
+
*
|
|
370
|
+
* The result follows the battery-power sign convention used across this file:
|
|
371
|
+
* positive = charging, negative = discharging. Returns `undefined` when neither
|
|
372
|
+
* battery string is present, so callers can fall through to another source.
|
|
373
|
+
*
|
|
374
|
+
* Exported as a free function so it can be unit-tested and reused by both the
|
|
375
|
+
* SunspecBattery live-power path and the SunspecInverter AC-fallback correction.
|
|
376
|
+
*/
|
|
377
|
+
export declare function sumMpptBatteryPowerW(mpptDataList: SunspecMPPTData[]): number | undefined;
|
|
301
378
|
export declare function selectLiveBatteryPowerW(mpptBatteryPowerW: number | undefined, batteryData: SunspecBatteryData | null): number | undefined;
|
|
302
379
|
export declare function filterFeaturesByCalibrationResult(detected: EnyoBatteryFeature[], result: CalibrationResult | undefined, controllable: readonly EnyoBatteryFeature[]): EnyoBatteryFeature[];
|
|
303
380
|
/**
|
|
@@ -366,7 +443,7 @@ export declare class SunspecBattery extends BaseSunspecDevice {
|
|
|
366
443
|
/**
|
|
367
444
|
* Update battery data and return data bus messages
|
|
368
445
|
*/
|
|
369
|
-
readData(clockId: string, resolution:
|
|
446
|
+
readData(clockId: string, resolution: EnyoDataBusMessageResolution): Promise<EnyoDataBusMessage[]>;
|
|
370
447
|
/**
|
|
371
448
|
* Extract battery power from MPPT strings with specific IDs
|
|
372
449
|
* StCha 3: Battery charging power (positive)
|
|
@@ -976,9 +976,11 @@ class SunspecModbusClient {
|
|
|
976
976
|
this.logRegisterRead(103, 50, 'Vendor Events 4', data.vendorEvents4, 'bitfield32');
|
|
977
977
|
const acEnergy = this.extractValue(buffer, 24, 'uint32', 2);
|
|
978
978
|
this.logRegisterRead(103, 24, 'AC Energy', acEnergy, 'acc32');
|
|
979
|
+
const whSf = this.isUnimplementedValue(scaleFactors.WH_SF, 'int16') ? 0 : scaleFactors.WH_SF;
|
|
979
980
|
data.acEnergy = !this.isUnimplementedValue(acEnergy, 'acc32')
|
|
980
|
-
? acEnergy * Math.pow(10,
|
|
981
|
+
? acEnergy * Math.pow(10, whSf)
|
|
981
982
|
: undefined;
|
|
983
|
+
data.acEnergyScaleFactor = whSf;
|
|
982
984
|
console.debug('[Model 103] Inverter Data:', data);
|
|
983
985
|
return data;
|
|
984
986
|
}
|
|
@@ -1038,9 +1040,11 @@ class SunspecModbusClient {
|
|
|
1038
1040
|
// Read AC Energy (32-bit accumulator) - Offset 24-25
|
|
1039
1041
|
const acEnergy = this.extractValue(buffer, 24, 'uint32', 2);
|
|
1040
1042
|
this.logRegisterRead(101, 24, 'AC Energy', acEnergy, 'acc32');
|
|
1043
|
+
const whSf = this.isUnimplementedValue(scaleFactors.WH_SF, 'int16') ? 0 : scaleFactors.WH_SF;
|
|
1041
1044
|
data.acEnergy = !this.isUnimplementedValue(acEnergy, 'acc32')
|
|
1042
|
-
? acEnergy * Math.pow(10,
|
|
1045
|
+
? acEnergy * Math.pow(10, whSf)
|
|
1043
1046
|
: undefined;
|
|
1047
|
+
data.acEnergyScaleFactor = whSf;
|
|
1044
1048
|
console.debug('[Model 101] Single Phase Inverter Data:', data);
|
|
1045
1049
|
return data;
|
|
1046
1050
|
}
|
package/dist/cjs/version.cjs
CHANGED
|
@@ -9,7 +9,7 @@ exports.getSdkVersion = getSdkVersion;
|
|
|
9
9
|
/**
|
|
10
10
|
* Current version of the enyo Energy App SDK.
|
|
11
11
|
*/
|
|
12
|
-
exports.SDK_VERSION = '0.0.
|
|
12
|
+
exports.SDK_VERSION = '0.0.97';
|
|
13
13
|
/**
|
|
14
14
|
* Gets the current SDK version.
|
|
15
15
|
* @returns The semantic version string of the SDK
|
package/dist/cjs/version.d.cts
CHANGED
|
@@ -142,10 +142,36 @@ export declare class SunspecInverter extends BaseSunspecDevice {
|
|
|
142
142
|
private errorState;
|
|
143
143
|
private snapshotService?;
|
|
144
144
|
private statusReassertedThisSession;
|
|
145
|
+
private lastGoodAcEnergyWh?;
|
|
146
|
+
private acEnergyDropStreak;
|
|
147
|
+
/** Consecutive corrupt reads that confirm a genuine reset/resync (vs a transient glitch). */
|
|
148
|
+
private static readonly AC_ENERGY_RESET_CONFIRM;
|
|
145
149
|
constructor(energyApp: EnergyApp, name: EnyoApplianceName[], networkDevice: EnyoNetworkDevice, sunspecClient: SunspecModbusClient, applianceManager: ApplianceManager, unitId?: number, port?: number, baseAddress?: number, capabilities?: SunspecInverterCapability[], retryConfig?: IRetryConfig, appliance?: EnyoAppliance, useTls?: boolean, pvPowerSource?: SunspecPvPowerSource);
|
|
146
150
|
connect(): Promise<void>;
|
|
147
151
|
disconnect(): Promise<void>;
|
|
148
|
-
readData(clockId: string, resolution:
|
|
152
|
+
readData(clockId: string, resolution: EnyoDataBusMessageResolution): Promise<EnyoDataBusMessage[]>;
|
|
153
|
+
/**
|
|
154
|
+
* Guard the cumulative AC-energy reading before it is published as
|
|
155
|
+
* `meterValueWh`. The SunSpec `WH` register is an `acc32` (high word + low
|
|
156
|
+
* word) × 10^WH_SF; at a low-word rollover / wake-up the words can be
|
|
157
|
+
* mis-combined, so a poll jumps by exactly one 16-bit word
|
|
158
|
+
* (`65536 × 10^WH_SF`) up or down and back — Dirk Wasow's flip-flop of
|
|
159
|
+
* 6,553,600 Wh. A lifetime accumulator is also monotonic non-decreasing.
|
|
160
|
+
*
|
|
161
|
+
* So a reading is corrupt when it either DECREASES or JUMPS UP by ≥ half a
|
|
162
|
+
* register quantum (real per-poll production is orders of magnitude smaller):
|
|
163
|
+
* we republish the last good value rather than emit it (a raw `max-min`
|
|
164
|
+
* downstream would otherwise inflate it into ~a whole register word). A
|
|
165
|
+
* suspect level that persists for `AC_ENERGY_RESET_CONFIRM` consecutive polls
|
|
166
|
+
* is treated as a genuine reset/resync and adopted.
|
|
167
|
+
*
|
|
168
|
+
* Float models (111/112/113) report `WH` as an IEEE-754 float with no acc32
|
|
169
|
+
* word-boundary artifact; they leave `scaleFactor` undefined. For them there
|
|
170
|
+
* is no register quantum, so we enforce monotonicity only (reject decreases)
|
|
171
|
+
* and accept any increase — the ½-quantum upper bound applies to int+SF
|
|
172
|
+
* models (101/103) alone.
|
|
173
|
+
*/
|
|
174
|
+
private sanitizeAcEnergyWh;
|
|
149
175
|
/**
|
|
150
176
|
* Decode all active error bits from the inverter event registers into
|
|
151
177
|
* `EnyoApplianceErrorCode`s. Override in a subclass to customize the
|
|
@@ -190,6 +216,28 @@ export declare class SunspecInverter extends BaseSunspecDevice {
|
|
|
190
216
|
* returned (not undefined) so the field is cleared on the appliance.
|
|
191
217
|
*/
|
|
192
218
|
private computeActiveProductionLimitW;
|
|
219
|
+
/**
|
|
220
|
+
* Set the grid-operator power production (feed-in) limit on the inverter.
|
|
221
|
+
*
|
|
222
|
+
* Writes Model 123 `WMaxLimPct` + `WMaxLim_Ena` (as a percentage of the
|
|
223
|
+
* Model 121 `WMax` nameplate). Pass `null` to remove the limit and return
|
|
224
|
+
* the inverter to unthrottled production.
|
|
225
|
+
*
|
|
226
|
+
* The SDK exposes this so a consumer that receives a grid-operator
|
|
227
|
+
* production-limit command (from the data bus or elsewhere) can apply it;
|
|
228
|
+
* subscribing to and reacting to that command is the consumer's job.
|
|
229
|
+
*
|
|
230
|
+
* @param limitW - Maximum production power in Watts, or `null` to remove the limit
|
|
231
|
+
* @returns `true` if the write succeeded, `false` otherwise
|
|
232
|
+
*/
|
|
233
|
+
setPowerProductionLimit(limitW: number | null): Promise<boolean>;
|
|
234
|
+
/**
|
|
235
|
+
* Read the currently active grid-operator power production (feed-in) limit
|
|
236
|
+
* from the inverter, in Watts. Returns `null` when no limit is active, the
|
|
237
|
+
* registers cannot be read, or the configured limit is not actually
|
|
238
|
+
* throttling (limit ≥ `WMax`). See {@link computeActiveProductionLimitW}.
|
|
239
|
+
*/
|
|
240
|
+
getPowerProductionLimit(): Promise<number | null>;
|
|
193
241
|
private mapOperatingState;
|
|
194
242
|
/**
|
|
195
243
|
* PV production in Watt, sourced according to the configured `pvPowerSource`:
|
|
@@ -207,17 +255,32 @@ export declare class SunspecInverter extends BaseSunspecDevice {
|
|
|
207
255
|
* Both inverter-total steps require a strictly positive value, so NOT_IMPLEMENTED
|
|
208
256
|
* DCW (decodes to 0) falls through to AC, and a negative AC reading (e.g. a hybrid
|
|
209
257
|
* importing from grid) falls through to 0 rather than reporting negative production.
|
|
210
|
-
*
|
|
211
|
-
*
|
|
212
|
-
*
|
|
258
|
+
*
|
|
259
|
+
* The AC fallback backs out battery power via `batteryPowerW` (signed: positive =
|
|
260
|
+
* charging, negative = discharging). A hybrid's AC total is PV − charge + discharge,
|
|
261
|
+
* so real PV = AC + batteryPowerW. Without this, a battery discharging at night while
|
|
262
|
+
* the MPPT is unreadable would be reported as phantom PV production. `batteryPowerW`
|
|
263
|
+
* is undefined when no live battery source is available, in which case AC is used
|
|
264
|
+
* uncorrected (still better than reporting 0).
|
|
265
|
+
*
|
|
266
|
+
* The returned `pvPowerW` is always clamped to ≥ 0 — PV production is non-negative by
|
|
267
|
+
* definition and must never surface as a negative value on the data bus.
|
|
213
268
|
*/
|
|
214
|
-
protected selectPvPowerW(dcStrings: EnyoDataBusInverterValuesV1String[], inverterData: SunspecInverterData): {
|
|
269
|
+
protected selectPvPowerW(dcStrings: EnyoDataBusInverterValuesV1String[], inverterData: SunspecInverterData, batteryPowerW?: number): {
|
|
215
270
|
pvPowerW: number;
|
|
216
271
|
source: string;
|
|
217
272
|
};
|
|
218
273
|
/**
|
|
219
|
-
*
|
|
220
|
-
*
|
|
274
|
+
* Whether {@link selectPvPowerW} will source PV from the inverter total (rather than
|
|
275
|
+
* the summed MPPT strings) for the given string count. Mppt never does; Inverter
|
|
276
|
+
* always does; Auto does only when there are no strings. Exposed so `readData` can
|
|
277
|
+
* decide up front whether it needs to fetch battery power for the AC correction.
|
|
278
|
+
*/
|
|
279
|
+
private wouldUseInverterTotal;
|
|
280
|
+
/**
|
|
281
|
+
* Inverter total PV power from Model 101: DCW when strictly positive, else AC (with
|
|
282
|
+
* battery power backed out) when the result is strictly positive, else 0. See
|
|
283
|
+
* {@link selectPvPowerW} for the battery correction and why positivity matters.
|
|
221
284
|
*/
|
|
222
285
|
private inverterTotalPvPowerW;
|
|
223
286
|
/**
|
|
@@ -298,6 +361,20 @@ export declare function detectFeaturesFromRegisters(batteryData: SunspecBatteryD
|
|
|
298
361
|
* Exported as a free function so the preference logic can be unit-tested
|
|
299
362
|
* without the full `SunspecBattery` scaffold.
|
|
300
363
|
*/
|
|
364
|
+
/**
|
|
365
|
+
* Sum battery charge/discharge power from Model 160 MPPT strings.
|
|
366
|
+
*
|
|
367
|
+
* - `StCha 3` → charging power (added, positive)
|
|
368
|
+
* - `StDisCha 4` → discharging power (subtracted)
|
|
369
|
+
*
|
|
370
|
+
* The result follows the battery-power sign convention used across this file:
|
|
371
|
+
* positive = charging, negative = discharging. Returns `undefined` when neither
|
|
372
|
+
* battery string is present, so callers can fall through to another source.
|
|
373
|
+
*
|
|
374
|
+
* Exported as a free function so it can be unit-tested and reused by both the
|
|
375
|
+
* SunspecBattery live-power path and the SunspecInverter AC-fallback correction.
|
|
376
|
+
*/
|
|
377
|
+
export declare function sumMpptBatteryPowerW(mpptDataList: SunspecMPPTData[]): number | undefined;
|
|
301
378
|
export declare function selectLiveBatteryPowerW(mpptBatteryPowerW: number | undefined, batteryData: SunspecBatteryData | null): number | undefined;
|
|
302
379
|
export declare function filterFeaturesByCalibrationResult(detected: EnyoBatteryFeature[], result: CalibrationResult | undefined, controllable: readonly EnyoBatteryFeature[]): EnyoBatteryFeature[];
|
|
303
380
|
/**
|
|
@@ -366,7 +443,7 @@ export declare class SunspecBattery extends BaseSunspecDevice {
|
|
|
366
443
|
/**
|
|
367
444
|
* Update battery data and return data bus messages
|
|
368
445
|
*/
|
|
369
|
-
readData(clockId: string, resolution:
|
|
446
|
+
readData(clockId: string, resolution: EnyoDataBusMessageResolution): Promise<EnyoDataBusMessage[]>;
|
|
370
447
|
/**
|
|
371
448
|
* Extract battery power from MPPT strings with specific IDs
|
|
372
449
|
* StCha 3: Battery charging power (positive)
|
package/dist/sunspec-devices.js
CHANGED
|
@@ -355,6 +355,13 @@ export class SunspecInverter extends BaseSunspecDevice {
|
|
|
355
355
|
// state reads healthy), so we force one re-assert of the current status on
|
|
356
356
|
// the first successful read of each session to converge the core.
|
|
357
357
|
statusReassertedThisSession = false;
|
|
358
|
+
// Last accepted cumulative AC-energy reading (Wh) and how many consecutive
|
|
359
|
+
// polls have reported a corrupt one (a decrease or a ≥½-register-quantum jump
|
|
360
|
+
// — the acc32 16-bit word-boundary artifact). See sanitizeAcEnergyWh.
|
|
361
|
+
lastGoodAcEnergyWh;
|
|
362
|
+
acEnergyDropStreak = 0;
|
|
363
|
+
/** Consecutive corrupt reads that confirm a genuine reset/resync (vs a transient glitch). */
|
|
364
|
+
static AC_ENERGY_RESET_CONFIRM = 3;
|
|
358
365
|
constructor(energyApp, name, networkDevice, sunspecClient, applianceManager, unitId = 1, port = 502, baseAddress = 40000, capabilities = [], retryConfig, appliance, useTls,
|
|
359
366
|
// Where pvPowerW is sourced from — see SunspecPvPowerSource. Defaults to
|
|
360
367
|
// Auto (MPPT strings, then Model 101 DCW/AC fallback). Use Mppt to report
|
|
@@ -482,7 +489,20 @@ export class SunspecInverter extends BaseSunspecDevice {
|
|
|
482
489
|
// to Connected. No-op unless this device is still marked offline.
|
|
483
490
|
await this.reassertConnectedIfRecovered();
|
|
484
491
|
if (inverterData) {
|
|
485
|
-
|
|
492
|
+
// When PV is sourced from the inverter total (no usable MPPT strings),
|
|
493
|
+
// the AC fallback includes any battery charge/discharge on a hybrid.
|
|
494
|
+
// Fetch the live battery power (positive = charging, negative =
|
|
495
|
+
// discharging) so selectPvPowerW can back it out — otherwise a battery
|
|
496
|
+
// discharging at night is reported as phantom PV production.
|
|
497
|
+
let batteryPowerW;
|
|
498
|
+
if (this.wouldUseInverterTotal(dcStrings.length)) {
|
|
499
|
+
batteryPowerW = sumMpptBatteryPowerW(mpptDataList);
|
|
500
|
+
if (batteryPowerW === undefined) {
|
|
501
|
+
const batteryData = await this.sunspecClient.readBatteryData(this.unitId);
|
|
502
|
+
batteryPowerW = selectLiveBatteryPowerW(undefined, batteryData);
|
|
503
|
+
}
|
|
504
|
+
}
|
|
505
|
+
const { pvPowerW, source: pvPowerSource } = this.selectPvPowerW(dcStrings, inverterData, batteryPowerW);
|
|
486
506
|
console.debug(`Got PV Power from ${pvPowerSource}: ${pvPowerW}W`);
|
|
487
507
|
const inverterMessage = {
|
|
488
508
|
id: randomUUID(),
|
|
@@ -500,7 +520,7 @@ export class SunspecInverter extends BaseSunspecDevice {
|
|
|
500
520
|
voltageL1: inverterData.voltageAN || 0,
|
|
501
521
|
voltageL2: inverterData.voltageBN ?? undefined,
|
|
502
522
|
voltageL3: inverterData.voltageCN ?? undefined,
|
|
503
|
-
meterValueWh: inverterData.acEnergy,
|
|
523
|
+
meterValueWh: this.sanitizeAcEnergyWh(inverterData.acEnergy, inverterData.acEnergyScaleFactor),
|
|
504
524
|
strings: dcStrings
|
|
505
525
|
}
|
|
506
526
|
};
|
|
@@ -526,6 +546,54 @@ export class SunspecInverter extends BaseSunspecDevice {
|
|
|
526
546
|
}
|
|
527
547
|
return messages;
|
|
528
548
|
}
|
|
549
|
+
/**
|
|
550
|
+
* Guard the cumulative AC-energy reading before it is published as
|
|
551
|
+
* `meterValueWh`. The SunSpec `WH` register is an `acc32` (high word + low
|
|
552
|
+
* word) × 10^WH_SF; at a low-word rollover / wake-up the words can be
|
|
553
|
+
* mis-combined, so a poll jumps by exactly one 16-bit word
|
|
554
|
+
* (`65536 × 10^WH_SF`) up or down and back — Dirk Wasow's flip-flop of
|
|
555
|
+
* 6,553,600 Wh. A lifetime accumulator is also monotonic non-decreasing.
|
|
556
|
+
*
|
|
557
|
+
* So a reading is corrupt when it either DECREASES or JUMPS UP by ≥ half a
|
|
558
|
+
* register quantum (real per-poll production is orders of magnitude smaller):
|
|
559
|
+
* we republish the last good value rather than emit it (a raw `max-min`
|
|
560
|
+
* downstream would otherwise inflate it into ~a whole register word). A
|
|
561
|
+
* suspect level that persists for `AC_ENERGY_RESET_CONFIRM` consecutive polls
|
|
562
|
+
* is treated as a genuine reset/resync and adopted.
|
|
563
|
+
*
|
|
564
|
+
* Float models (111/112/113) report `WH` as an IEEE-754 float with no acc32
|
|
565
|
+
* word-boundary artifact; they leave `scaleFactor` undefined. For them there
|
|
566
|
+
* is no register quantum, so we enforce monotonicity only (reject decreases)
|
|
567
|
+
* and accept any increase — the ½-quantum upper bound applies to int+SF
|
|
568
|
+
* models (101/103) alone.
|
|
569
|
+
*/
|
|
570
|
+
sanitizeAcEnergyWh(raw, scaleFactor) {
|
|
571
|
+
if (raw == null)
|
|
572
|
+
return undefined;
|
|
573
|
+
if (this.lastGoodAcEnergyWh == null) {
|
|
574
|
+
this.lastGoodAcEnergyWh = raw;
|
|
575
|
+
this.acEnergyDropStreak = 0;
|
|
576
|
+
return raw;
|
|
577
|
+
}
|
|
578
|
+
const halfQuantumWh = scaleFactor != null ? 0.5 * 65536 * Math.pow(10, scaleFactor) : Infinity;
|
|
579
|
+
const delta = raw - this.lastGoodAcEnergyWh;
|
|
580
|
+
const plausible = delta >= 0 && delta < halfQuantumWh;
|
|
581
|
+
if (plausible) {
|
|
582
|
+
this.lastGoodAcEnergyWh = raw;
|
|
583
|
+
this.acEnergyDropStreak = 0;
|
|
584
|
+
return raw;
|
|
585
|
+
}
|
|
586
|
+
// A decrease or a ≥½-quantum jump — the acc32 word-boundary artifact.
|
|
587
|
+
this.acEnergyDropStreak++;
|
|
588
|
+
if (this.acEnergyDropStreak >= SunspecInverter.AC_ENERGY_RESET_CONFIRM) {
|
|
589
|
+
console.warn(`Notify_Devs: ${this.constructor.name} ${this.applianceId}: AC energy resync confirmed (${this.lastGoodAcEnergyWh} -> ${raw} Wh), adopting new baseline`);
|
|
590
|
+
this.lastGoodAcEnergyWh = raw;
|
|
591
|
+
this.acEnergyDropStreak = 0;
|
|
592
|
+
return raw;
|
|
593
|
+
}
|
|
594
|
+
console.warn(`Notify_Devs: ${this.constructor.name} ${this.applianceId}: rejecting corrupt AC energy reading ${raw} Wh (last good ${this.lastGoodAcEnergyWh} Wh, Δ=${delta}), republishing last good`);
|
|
595
|
+
return this.lastGoodAcEnergyWh;
|
|
596
|
+
}
|
|
529
597
|
/**
|
|
530
598
|
* Decode all active error bits from the inverter event registers into
|
|
531
599
|
* `EnyoApplianceErrorCode`s. Override in a subclass to customize the
|
|
@@ -713,6 +781,34 @@ export class SunspecInverter extends BaseSunspecDevice {
|
|
|
713
781
|
return null;
|
|
714
782
|
return limitW;
|
|
715
783
|
}
|
|
784
|
+
/**
|
|
785
|
+
* Set the grid-operator power production (feed-in) limit on the inverter.
|
|
786
|
+
*
|
|
787
|
+
* Writes Model 123 `WMaxLimPct` + `WMaxLim_Ena` (as a percentage of the
|
|
788
|
+
* Model 121 `WMax` nameplate). Pass `null` to remove the limit and return
|
|
789
|
+
* the inverter to unthrottled production.
|
|
790
|
+
*
|
|
791
|
+
* The SDK exposes this so a consumer that receives a grid-operator
|
|
792
|
+
* production-limit command (from the data bus or elsewhere) can apply it;
|
|
793
|
+
* subscribing to and reacting to that command is the consumer's job.
|
|
794
|
+
*
|
|
795
|
+
* @param limitW - Maximum production power in Watts, or `null` to remove the limit
|
|
796
|
+
* @returns `true` if the write succeeded, `false` otherwise
|
|
797
|
+
*/
|
|
798
|
+
async setPowerProductionLimit(limitW) {
|
|
799
|
+
return this.sunspecClient.setFeedInLimit(this.unitId, limitW);
|
|
800
|
+
}
|
|
801
|
+
/**
|
|
802
|
+
* Read the currently active grid-operator power production (feed-in) limit
|
|
803
|
+
* from the inverter, in Watts. Returns `null` when no limit is active, the
|
|
804
|
+
* registers cannot be read, or the configured limit is not actually
|
|
805
|
+
* throttling (limit ≥ `WMax`). See {@link computeActiveProductionLimitW}.
|
|
806
|
+
*/
|
|
807
|
+
async getPowerProductionLimit() {
|
|
808
|
+
const settings = await this.sunspecClient.readInverterSettings(this.unitId);
|
|
809
|
+
const controls = await this.sunspecClient.readInverterControls(this.unitId);
|
|
810
|
+
return this.computeActiveProductionLimitW(settings, controls);
|
|
811
|
+
}
|
|
716
812
|
mapOperatingState(state) {
|
|
717
813
|
if (!state)
|
|
718
814
|
return EnyoInverterStateEnum.Off;
|
|
@@ -744,29 +840,54 @@ export class SunspecInverter extends BaseSunspecDevice {
|
|
|
744
840
|
* Both inverter-total steps require a strictly positive value, so NOT_IMPLEMENTED
|
|
745
841
|
* DCW (decodes to 0) falls through to AC, and a negative AC reading (e.g. a hybrid
|
|
746
842
|
* importing from grid) falls through to 0 rather than reporting negative production.
|
|
747
|
-
*
|
|
748
|
-
*
|
|
749
|
-
*
|
|
843
|
+
*
|
|
844
|
+
* The AC fallback backs out battery power via `batteryPowerW` (signed: positive =
|
|
845
|
+
* charging, negative = discharging). A hybrid's AC total is PV − charge + discharge,
|
|
846
|
+
* so real PV = AC + batteryPowerW. Without this, a battery discharging at night while
|
|
847
|
+
* the MPPT is unreadable would be reported as phantom PV production. `batteryPowerW`
|
|
848
|
+
* is undefined when no live battery source is available, in which case AC is used
|
|
849
|
+
* uncorrected (still better than reporting 0).
|
|
850
|
+
*
|
|
851
|
+
* The returned `pvPowerW` is always clamped to ≥ 0 — PV production is non-negative by
|
|
852
|
+
* definition and must never surface as a negative value on the data bus.
|
|
750
853
|
*/
|
|
751
|
-
selectPvPowerW(dcStrings, inverterData) {
|
|
752
|
-
|
|
753
|
-
|
|
754
|
-
|
|
755
|
-
if (useStrings) {
|
|
756
|
-
return { pvPowerW: stringSumW, source: 'DC strings' };
|
|
854
|
+
selectPvPowerW(dcStrings, inverterData, batteryPowerW) {
|
|
855
|
+
if (!this.wouldUseInverterTotal(dcStrings.length)) {
|
|
856
|
+
const stringSumW = dcStrings.reduce((sum, s) => sum + (s.powerW || 0), 0);
|
|
857
|
+
return { pvPowerW: Math.max(0, stringSumW), source: 'DC strings' };
|
|
757
858
|
}
|
|
758
|
-
return this.inverterTotalPvPowerW(inverterData);
|
|
859
|
+
return this.inverterTotalPvPowerW(inverterData, batteryPowerW);
|
|
759
860
|
}
|
|
760
861
|
/**
|
|
761
|
-
*
|
|
762
|
-
*
|
|
862
|
+
* Whether {@link selectPvPowerW} will source PV from the inverter total (rather than
|
|
863
|
+
* the summed MPPT strings) for the given string count. Mppt never does; Inverter
|
|
864
|
+
* always does; Auto does only when there are no strings. Exposed so `readData` can
|
|
865
|
+
* decide up front whether it needs to fetch battery power for the AC correction.
|
|
763
866
|
*/
|
|
764
|
-
|
|
867
|
+
wouldUseInverterTotal(dcStringCount) {
|
|
868
|
+
if (this.pvPowerSource === SunspecPvPowerSource.Mppt)
|
|
869
|
+
return false;
|
|
870
|
+
if (this.pvPowerSource === SunspecPvPowerSource.Inverter)
|
|
871
|
+
return true;
|
|
872
|
+
return dcStringCount === 0; // Auto
|
|
873
|
+
}
|
|
874
|
+
/**
|
|
875
|
+
* Inverter total PV power from Model 101: DCW when strictly positive, else AC (with
|
|
876
|
+
* battery power backed out) when the result is strictly positive, else 0. See
|
|
877
|
+
* {@link selectPvPowerW} for the battery correction and why positivity matters.
|
|
878
|
+
*/
|
|
879
|
+
inverterTotalPvPowerW(inverterData, batteryPowerW) {
|
|
765
880
|
if (typeof inverterData.dcPower === 'number' && inverterData.dcPower > 0) {
|
|
766
881
|
return { pvPowerW: inverterData.dcPower, source: 'DC power (Model 101)' };
|
|
767
882
|
}
|
|
768
883
|
if (typeof inverterData.acPower === 'number' && inverterData.acPower > 0) {
|
|
769
|
-
|
|
884
|
+
// AC = PV − charge + discharge on a hybrid; batteryPowerW is signed
|
|
885
|
+
// (positive = charging, negative = discharging), so PV = AC + batteryPowerW.
|
|
886
|
+
const correctedW = inverterData.acPower + (batteryPowerW ?? 0);
|
|
887
|
+
if (correctedW > 0) {
|
|
888
|
+
return { pvPowerW: correctedW, source: 'AC power (Model 101)' };
|
|
889
|
+
}
|
|
890
|
+
return { pvPowerW: 0, source: 'none' };
|
|
770
891
|
}
|
|
771
892
|
return { pvPowerW: 0, source: 'none' };
|
|
772
893
|
}
|
|
@@ -998,6 +1119,31 @@ export function detectFeaturesFromRegisters(batteryData) {
|
|
|
998
1119
|
* Exported as a free function so the preference logic can be unit-tested
|
|
999
1120
|
* without the full `SunspecBattery` scaffold.
|
|
1000
1121
|
*/
|
|
1122
|
+
/**
|
|
1123
|
+
* Sum battery charge/discharge power from Model 160 MPPT strings.
|
|
1124
|
+
*
|
|
1125
|
+
* - `StCha 3` → charging power (added, positive)
|
|
1126
|
+
* - `StDisCha 4` → discharging power (subtracted)
|
|
1127
|
+
*
|
|
1128
|
+
* The result follows the battery-power sign convention used across this file:
|
|
1129
|
+
* positive = charging, negative = discharging. Returns `undefined` when neither
|
|
1130
|
+
* battery string is present, so callers can fall through to another source.
|
|
1131
|
+
*
|
|
1132
|
+
* Exported as a free function so it can be unit-tested and reused by both the
|
|
1133
|
+
* SunspecBattery live-power path and the SunspecInverter AC-fallback correction.
|
|
1134
|
+
*/
|
|
1135
|
+
export function sumMpptBatteryPowerW(mpptDataList) {
|
|
1136
|
+
let batteryPowerW;
|
|
1137
|
+
for (const mppt of mpptDataList) {
|
|
1138
|
+
if (mppt.stringId === 'StCha 3' && mppt.dcPower !== undefined) {
|
|
1139
|
+
batteryPowerW = (batteryPowerW ?? 0) + mppt.dcPower;
|
|
1140
|
+
}
|
|
1141
|
+
else if (mppt.stringId === 'StDisCha 4' && mppt.dcPower !== undefined) {
|
|
1142
|
+
batteryPowerW = (batteryPowerW ?? 0) - mppt.dcPower;
|
|
1143
|
+
}
|
|
1144
|
+
}
|
|
1145
|
+
return batteryPowerW;
|
|
1146
|
+
}
|
|
1001
1147
|
export function selectLiveBatteryPowerW(mpptBatteryPowerW, batteryData) {
|
|
1002
1148
|
if (mpptBatteryPowerW !== undefined) {
|
|
1003
1149
|
return mpptBatteryPowerW;
|
|
@@ -1337,18 +1483,7 @@ export class SunspecBattery extends BaseSunspecDevice {
|
|
|
1337
1483
|
* StDisCha 4: Battery discharging power (negative)
|
|
1338
1484
|
*/
|
|
1339
1485
|
extractBatteryPowerFromMPPT(mpptDataList) {
|
|
1340
|
-
|
|
1341
|
-
mpptDataList.forEach((mppt) => {
|
|
1342
|
-
if (mppt.stringId === 'StCha 3' && mppt.dcPower !== undefined) {
|
|
1343
|
-
// Charging power is positive
|
|
1344
|
-
batteryPowerW = (batteryPowerW || 0) + mppt.dcPower;
|
|
1345
|
-
}
|
|
1346
|
-
else if (mppt.stringId === 'StDisCha 4' && mppt.dcPower !== undefined) {
|
|
1347
|
-
// Discharging power is negative
|
|
1348
|
-
batteryPowerW = (batteryPowerW || 0) - mppt.dcPower;
|
|
1349
|
-
}
|
|
1350
|
-
});
|
|
1351
|
-
return batteryPowerW;
|
|
1486
|
+
return sumMpptBatteryPowerW(mpptDataList);
|
|
1352
1487
|
}
|
|
1353
1488
|
/**
|
|
1354
1489
|
* Determine battery state from MPPT strings
|
|
@@ -971,9 +971,11 @@ export class SunspecModbusClient {
|
|
|
971
971
|
this.logRegisterRead(103, 50, 'Vendor Events 4', data.vendorEvents4, 'bitfield32');
|
|
972
972
|
const acEnergy = this.extractValue(buffer, 24, 'uint32', 2);
|
|
973
973
|
this.logRegisterRead(103, 24, 'AC Energy', acEnergy, 'acc32');
|
|
974
|
+
const whSf = this.isUnimplementedValue(scaleFactors.WH_SF, 'int16') ? 0 : scaleFactors.WH_SF;
|
|
974
975
|
data.acEnergy = !this.isUnimplementedValue(acEnergy, 'acc32')
|
|
975
|
-
? acEnergy * Math.pow(10,
|
|
976
|
+
? acEnergy * Math.pow(10, whSf)
|
|
976
977
|
: undefined;
|
|
978
|
+
data.acEnergyScaleFactor = whSf;
|
|
977
979
|
console.debug('[Model 103] Inverter Data:', data);
|
|
978
980
|
return data;
|
|
979
981
|
}
|
|
@@ -1033,9 +1035,11 @@ export class SunspecModbusClient {
|
|
|
1033
1035
|
// Read AC Energy (32-bit accumulator) - Offset 24-25
|
|
1034
1036
|
const acEnergy = this.extractValue(buffer, 24, 'uint32', 2);
|
|
1035
1037
|
this.logRegisterRead(101, 24, 'AC Energy', acEnergy, 'acc32');
|
|
1038
|
+
const whSf = this.isUnimplementedValue(scaleFactors.WH_SF, 'int16') ? 0 : scaleFactors.WH_SF;
|
|
1036
1039
|
data.acEnergy = !this.isUnimplementedValue(acEnergy, 'acc32')
|
|
1037
|
-
? acEnergy * Math.pow(10,
|
|
1040
|
+
? acEnergy * Math.pow(10, whSf)
|
|
1038
1041
|
: undefined;
|
|
1042
|
+
data.acEnergyScaleFactor = whSf;
|
|
1039
1043
|
console.debug('[Model 101] Single Phase Inverter Data:', data);
|
|
1040
1044
|
return data;
|
|
1041
1045
|
}
|
package/dist/version.d.ts
CHANGED
package/dist/version.js
CHANGED
package/package.json
CHANGED
|
@@ -1,6 +1,6 @@
|
|
|
1
1
|
{
|
|
2
2
|
"name": "@enyo-energy/sunspec-sdk",
|
|
3
|
-
"version": "0.0.
|
|
3
|
+
"version": "0.0.97",
|
|
4
4
|
"description": "enyo Energy Sunspec SDK",
|
|
5
5
|
"type": "module",
|
|
6
6
|
"main": "dist/index.js",
|
|
@@ -41,7 +41,7 @@
|
|
|
41
41
|
},
|
|
42
42
|
"dependencies": {
|
|
43
43
|
"@enyo-energy/appliance-calibration": "0.0.2",
|
|
44
|
-
"@enyo-energy/energy-app-sdk": "^0.0.
|
|
44
|
+
"@enyo-energy/energy-app-sdk": "^0.0.175"
|
|
45
45
|
},
|
|
46
46
|
"volta": {
|
|
47
47
|
"node": "22.17.0"
|