@enyo-energy/sunspec-sdk 0.0.94 → 0.0.96
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/dist/cjs/sunspec-devices.cjs +137 -4
- package/dist/cjs/sunspec-devices.d.cts +82 -4
- package/dist/cjs/sunspec-interfaces.cjs +15 -1
- package/dist/cjs/sunspec-interfaces.d.cts +14 -0
- package/dist/cjs/sunspec-modbus-client.cjs +6 -2
- package/dist/cjs/version.cjs +1 -1
- package/dist/cjs/version.d.cts +1 -1
- package/dist/sunspec-devices.d.ts +82 -4
- package/dist/sunspec-devices.js +138 -5
- package/dist/sunspec-interfaces.d.ts +14 -0
- package/dist/sunspec-interfaces.js +14 -0
- package/dist/sunspec-modbus-client.js +6 -2
- package/dist/version.d.ts +1 -1
- package/dist/version.js +1 -1
- package/package.json +2 -2
|
@@ -341,6 +341,7 @@ exports.BaseSunspecDevice = BaseSunspecDevice;
|
|
|
341
341
|
*/
|
|
342
342
|
class SunspecInverter extends BaseSunspecDevice {
|
|
343
343
|
capabilities;
|
|
344
|
+
pvPowerSource;
|
|
344
345
|
/** Emit a connection-lost faulted status after this many consecutive failed reconnect attempts. */
|
|
345
346
|
static CONNECTION_FAULT_THRESHOLD = 3;
|
|
346
347
|
/**
|
|
@@ -361,9 +362,23 @@ class SunspecInverter extends BaseSunspecDevice {
|
|
|
361
362
|
// state reads healthy), so we force one re-assert of the current status on
|
|
362
363
|
// the first successful read of each session to converge the core.
|
|
363
364
|
statusReassertedThisSession = false;
|
|
364
|
-
|
|
365
|
+
// Last accepted cumulative AC-energy reading (Wh) and how many consecutive
|
|
366
|
+
// polls have reported a corrupt one (a decrease or a ≥½-register-quantum jump
|
|
367
|
+
// — the acc32 16-bit word-boundary artifact). See sanitizeAcEnergyWh.
|
|
368
|
+
lastGoodAcEnergyWh;
|
|
369
|
+
acEnergyDropStreak = 0;
|
|
370
|
+
/** Consecutive corrupt reads that confirm a genuine reset/resync (vs a transient glitch). */
|
|
371
|
+
static AC_ENERGY_RESET_CONFIRM = 3;
|
|
372
|
+
constructor(energyApp, name, networkDevice, sunspecClient, applianceManager, unitId = 1, port = 502, baseAddress = 40000, capabilities = [], retryConfig, appliance, useTls,
|
|
373
|
+
// Where pvPowerW is sourced from — see SunspecPvPowerSource. Defaults to
|
|
374
|
+
// Auto (MPPT strings, then Model 101 DCW/AC fallback). Use Mppt to report
|
|
375
|
+
// only summed MPPT strings, or Inverter to use only the inverter total —
|
|
376
|
+
// e.g. for devices whose Model 160 strings are unreliable or whose AC
|
|
377
|
+
// includes non-PV sources (a hybrid's battery discharge).
|
|
378
|
+
pvPowerSource = sunspec_interfaces_js_1.SunspecPvPowerSource.Auto) {
|
|
365
379
|
super(energyApp, name, networkDevice, sunspecClient, applianceManager, unitId, port, baseAddress, retryConfig, appliance, useTls);
|
|
366
380
|
this.capabilities = capabilities;
|
|
381
|
+
this.pvPowerSource = pvPowerSource;
|
|
367
382
|
}
|
|
368
383
|
async connect() {
|
|
369
384
|
// Ensure Sunspec client is connected
|
|
@@ -481,8 +496,8 @@ class SunspecInverter extends BaseSunspecDevice {
|
|
|
481
496
|
// to Connected. No-op unless this device is still marked offline.
|
|
482
497
|
await this.reassertConnectedIfRecovered();
|
|
483
498
|
if (inverterData) {
|
|
484
|
-
const pvPowerW
|
|
485
|
-
console.debug(`Got PV Power from
|
|
499
|
+
const { pvPowerW, source: pvPowerSource } = this.selectPvPowerW(dcStrings, inverterData);
|
|
500
|
+
console.debug(`Got PV Power from ${pvPowerSource}: ${pvPowerW}W`);
|
|
486
501
|
const inverterMessage = {
|
|
487
502
|
id: (0, node_crypto_1.randomUUID)(),
|
|
488
503
|
message: enyo_data_bus_value_js_1.EnyoDataBusMessageEnum.InverterValuesUpdateV1,
|
|
@@ -499,7 +514,7 @@ class SunspecInverter extends BaseSunspecDevice {
|
|
|
499
514
|
voltageL1: inverterData.voltageAN || 0,
|
|
500
515
|
voltageL2: inverterData.voltageBN ?? undefined,
|
|
501
516
|
voltageL3: inverterData.voltageCN ?? undefined,
|
|
502
|
-
meterValueWh: inverterData.acEnergy,
|
|
517
|
+
meterValueWh: this.sanitizeAcEnergyWh(inverterData.acEnergy, inverterData.acEnergyScaleFactor),
|
|
503
518
|
strings: dcStrings
|
|
504
519
|
}
|
|
505
520
|
};
|
|
@@ -525,6 +540,54 @@ class SunspecInverter extends BaseSunspecDevice {
|
|
|
525
540
|
}
|
|
526
541
|
return messages;
|
|
527
542
|
}
|
|
543
|
+
/**
|
|
544
|
+
* Guard the cumulative AC-energy reading before it is published as
|
|
545
|
+
* `meterValueWh`. The SunSpec `WH` register is an `acc32` (high word + low
|
|
546
|
+
* word) × 10^WH_SF; at a low-word rollover / wake-up the words can be
|
|
547
|
+
* mis-combined, so a poll jumps by exactly one 16-bit word
|
|
548
|
+
* (`65536 × 10^WH_SF`) up or down and back — Dirk Wasow's flip-flop of
|
|
549
|
+
* 6,553,600 Wh. A lifetime accumulator is also monotonic non-decreasing.
|
|
550
|
+
*
|
|
551
|
+
* So a reading is corrupt when it either DECREASES or JUMPS UP by ≥ half a
|
|
552
|
+
* register quantum (real per-poll production is orders of magnitude smaller):
|
|
553
|
+
* we republish the last good value rather than emit it (a raw `max-min`
|
|
554
|
+
* downstream would otherwise inflate it into ~a whole register word). A
|
|
555
|
+
* suspect level that persists for `AC_ENERGY_RESET_CONFIRM` consecutive polls
|
|
556
|
+
* is treated as a genuine reset/resync and adopted.
|
|
557
|
+
*
|
|
558
|
+
* Float models (111/112/113) report `WH` as an IEEE-754 float with no acc32
|
|
559
|
+
* word-boundary artifact; they leave `scaleFactor` undefined. For them there
|
|
560
|
+
* is no register quantum, so we enforce monotonicity only (reject decreases)
|
|
561
|
+
* and accept any increase — the ½-quantum upper bound applies to int+SF
|
|
562
|
+
* models (101/103) alone.
|
|
563
|
+
*/
|
|
564
|
+
sanitizeAcEnergyWh(raw, scaleFactor) {
|
|
565
|
+
if (raw == null)
|
|
566
|
+
return undefined;
|
|
567
|
+
if (this.lastGoodAcEnergyWh == null) {
|
|
568
|
+
this.lastGoodAcEnergyWh = raw;
|
|
569
|
+
this.acEnergyDropStreak = 0;
|
|
570
|
+
return raw;
|
|
571
|
+
}
|
|
572
|
+
const halfQuantumWh = scaleFactor != null ? 0.5 * 65536 * Math.pow(10, scaleFactor) : Infinity;
|
|
573
|
+
const delta = raw - this.lastGoodAcEnergyWh;
|
|
574
|
+
const plausible = delta >= 0 && delta < halfQuantumWh;
|
|
575
|
+
if (plausible) {
|
|
576
|
+
this.lastGoodAcEnergyWh = raw;
|
|
577
|
+
this.acEnergyDropStreak = 0;
|
|
578
|
+
return raw;
|
|
579
|
+
}
|
|
580
|
+
// A decrease or a ≥½-quantum jump — the acc32 word-boundary artifact.
|
|
581
|
+
this.acEnergyDropStreak++;
|
|
582
|
+
if (this.acEnergyDropStreak >= SunspecInverter.AC_ENERGY_RESET_CONFIRM) {
|
|
583
|
+
console.warn(`Notify_Devs: ${this.constructor.name} ${this.applianceId}: AC energy resync confirmed (${this.lastGoodAcEnergyWh} -> ${raw} Wh), adopting new baseline`);
|
|
584
|
+
this.lastGoodAcEnergyWh = raw;
|
|
585
|
+
this.acEnergyDropStreak = 0;
|
|
586
|
+
return raw;
|
|
587
|
+
}
|
|
588
|
+
console.warn(`Notify_Devs: ${this.constructor.name} ${this.applianceId}: rejecting corrupt AC energy reading ${raw} Wh (last good ${this.lastGoodAcEnergyWh} Wh, Δ=${delta}), republishing last good`);
|
|
589
|
+
return this.lastGoodAcEnergyWh;
|
|
590
|
+
}
|
|
528
591
|
/**
|
|
529
592
|
* Decode all active error bits from the inverter event registers into
|
|
530
593
|
* `EnyoApplianceErrorCode`s. Override in a subclass to customize the
|
|
@@ -712,6 +775,34 @@ class SunspecInverter extends BaseSunspecDevice {
|
|
|
712
775
|
return null;
|
|
713
776
|
return limitW;
|
|
714
777
|
}
|
|
778
|
+
/**
|
|
779
|
+
* Set the grid-operator power production (feed-in) limit on the inverter.
|
|
780
|
+
*
|
|
781
|
+
* Writes Model 123 `WMaxLimPct` + `WMaxLim_Ena` (as a percentage of the
|
|
782
|
+
* Model 121 `WMax` nameplate). Pass `null` to remove the limit and return
|
|
783
|
+
* the inverter to unthrottled production.
|
|
784
|
+
*
|
|
785
|
+
* The SDK exposes this so a consumer that receives a grid-operator
|
|
786
|
+
* production-limit command (from the data bus or elsewhere) can apply it;
|
|
787
|
+
* subscribing to and reacting to that command is the consumer's job.
|
|
788
|
+
*
|
|
789
|
+
* @param limitW - Maximum production power in Watts, or `null` to remove the limit
|
|
790
|
+
* @returns `true` if the write succeeded, `false` otherwise
|
|
791
|
+
*/
|
|
792
|
+
async setPowerProductionLimit(limitW) {
|
|
793
|
+
return this.sunspecClient.setFeedInLimit(this.unitId, limitW);
|
|
794
|
+
}
|
|
795
|
+
/**
|
|
796
|
+
* Read the currently active grid-operator power production (feed-in) limit
|
|
797
|
+
* from the inverter, in Watts. Returns `null` when no limit is active, the
|
|
798
|
+
* registers cannot be read, or the configured limit is not actually
|
|
799
|
+
* throttling (limit ≥ `WMax`). See {@link computeActiveProductionLimitW}.
|
|
800
|
+
*/
|
|
801
|
+
async getPowerProductionLimit() {
|
|
802
|
+
const settings = await this.sunspecClient.readInverterSettings(this.unitId);
|
|
803
|
+
const controls = await this.sunspecClient.readInverterControls(this.unitId);
|
|
804
|
+
return this.computeActiveProductionLimitW(settings, controls);
|
|
805
|
+
}
|
|
715
806
|
mapOperatingState(state) {
|
|
716
807
|
if (!state)
|
|
717
808
|
return enyo_data_bus_value_js_1.EnyoInverterStateEnum.Off;
|
|
@@ -727,6 +818,48 @@ class SunspecInverter extends BaseSunspecDevice {
|
|
|
727
818
|
};
|
|
728
819
|
return stateMap[state] || enyo_data_bus_value_js_1.EnyoInverterStateEnum.Off;
|
|
729
820
|
}
|
|
821
|
+
/**
|
|
822
|
+
* PV production in Watt, sourced according to the configured `pvPowerSource`:
|
|
823
|
+
*
|
|
824
|
+
* - Auto (default): summed per-string MPPT DC power (Model 160) when strings are
|
|
825
|
+
* present — most granular, isolates PV — otherwise the inverter total via
|
|
826
|
+
* {@link inverterTotalPvPowerW} (Model 101 DCW, then AC). The fallback is only
|
|
827
|
+
* consulted when there are no strings, so inverters with working MPPT are
|
|
828
|
+
* unaffected. It lets a producing inverter that exposes no DC telemetry (e.g. an
|
|
829
|
+
* SMA Sunny Boy with Model 160 unreadable and DCW NOT_IMPLEMENTED) still report
|
|
830
|
+
* real production instead of 0 W.
|
|
831
|
+
* - Mppt: only the summed MPPT strings; a stringless inverter reports 0 W.
|
|
832
|
+
* - Inverter: only the inverter total (DCW, then AC); MPPT strings are ignored.
|
|
833
|
+
*
|
|
834
|
+
* Both inverter-total steps require a strictly positive value, so NOT_IMPLEMENTED
|
|
835
|
+
* DCW (decodes to 0) falls through to AC, and a negative AC reading (e.g. a hybrid
|
|
836
|
+
* importing from grid) falls through to 0 rather than reporting negative production.
|
|
837
|
+
* Edge case: in Auto/Inverter a hybrid discharging its battery while its MPPT is
|
|
838
|
+
* unreadable reports AC (incl. battery) rather than 0 — acceptable, and strictly
|
|
839
|
+
* better than reporting 0.
|
|
840
|
+
*/
|
|
841
|
+
selectPvPowerW(dcStrings, inverterData) {
|
|
842
|
+
const stringSumW = dcStrings.reduce((sum, s) => sum + (s.powerW || 0), 0);
|
|
843
|
+
const useStrings = this.pvPowerSource === sunspec_interfaces_js_1.SunspecPvPowerSource.Mppt ||
|
|
844
|
+
(this.pvPowerSource === sunspec_interfaces_js_1.SunspecPvPowerSource.Auto && dcStrings.length > 0);
|
|
845
|
+
if (useStrings) {
|
|
846
|
+
return { pvPowerW: stringSumW, source: 'DC strings' };
|
|
847
|
+
}
|
|
848
|
+
return this.inverterTotalPvPowerW(inverterData);
|
|
849
|
+
}
|
|
850
|
+
/**
|
|
851
|
+
* Inverter total PV power from Model 101: DCW when strictly positive, else AC when
|
|
852
|
+
* strictly positive, else 0. See {@link selectPvPowerW} for why positivity matters.
|
|
853
|
+
*/
|
|
854
|
+
inverterTotalPvPowerW(inverterData) {
|
|
855
|
+
if (typeof inverterData.dcPower === 'number' && inverterData.dcPower > 0) {
|
|
856
|
+
return { pvPowerW: inverterData.dcPower, source: 'DC power (Model 101)' };
|
|
857
|
+
}
|
|
858
|
+
if (typeof inverterData.acPower === 'number' && inverterData.acPower > 0) {
|
|
859
|
+
return { pvPowerW: inverterData.acPower, source: 'AC power (Model 101)' };
|
|
860
|
+
}
|
|
861
|
+
return { pvPowerW: 0, source: 'none' };
|
|
862
|
+
}
|
|
730
863
|
/**
|
|
731
864
|
* Map MPPT data to DC string structure for data bus
|
|
732
865
|
* Filters out battery-related strings (StCha 3, StDisCha 4)
|
|
@@ -1,4 +1,4 @@
|
|
|
1
|
-
import { type IRetryConfig, type SunspecBatteryBaseData, SunspecBatteryCapability, type SunspecBatteryControls, type SunspecBatteryData, type SunspecBatteryFeatureMode, type SunspecInverterData, SunspecInverterCapability, SunspecMeterCapability, type SunspecMPPTData, SunspecStorageMode } from "./sunspec-interfaces.cjs";
|
|
1
|
+
import { type IRetryConfig, type SunspecBatteryBaseData, SunspecBatteryCapability, type SunspecBatteryControls, type SunspecBatteryData, type SunspecBatteryFeatureMode, type SunspecInverterData, SunspecInverterCapability, SunspecPvPowerSource, SunspecMeterCapability, type SunspecMPPTData, SunspecStorageMode } from "./sunspec-interfaces.cjs";
|
|
2
2
|
import { ApplianceManager, EnergyApp } from "@enyo-energy/energy-app-sdk";
|
|
3
3
|
import { type EnyoAppliance, type EnyoApplianceErrorCode, EnyoApplianceName } from "@enyo-energy/energy-app-sdk/dist/types/enyo-appliance.js";
|
|
4
4
|
import { EnyoNetworkDevice } from "@enyo-energy/energy-app-sdk/dist/types/enyo-network-device.js";
|
|
@@ -127,6 +127,7 @@ export declare abstract class BaseSunspecDevice {
|
|
|
127
127
|
*/
|
|
128
128
|
export declare class SunspecInverter extends BaseSunspecDevice {
|
|
129
129
|
private readonly capabilities;
|
|
130
|
+
private readonly pvPowerSource;
|
|
130
131
|
/** Emit a connection-lost faulted status after this many consecutive failed reconnect attempts. */
|
|
131
132
|
private static readonly CONNECTION_FAULT_THRESHOLD;
|
|
132
133
|
/**
|
|
@@ -141,10 +142,36 @@ export declare class SunspecInverter extends BaseSunspecDevice {
|
|
|
141
142
|
private errorState;
|
|
142
143
|
private snapshotService?;
|
|
143
144
|
private statusReassertedThisSession;
|
|
144
|
-
|
|
145
|
+
private lastGoodAcEnergyWh?;
|
|
146
|
+
private acEnergyDropStreak;
|
|
147
|
+
/** Consecutive corrupt reads that confirm a genuine reset/resync (vs a transient glitch). */
|
|
148
|
+
private static readonly AC_ENERGY_RESET_CONFIRM;
|
|
149
|
+
constructor(energyApp: EnergyApp, name: EnyoApplianceName[], networkDevice: EnyoNetworkDevice, sunspecClient: SunspecModbusClient, applianceManager: ApplianceManager, unitId?: number, port?: number, baseAddress?: number, capabilities?: SunspecInverterCapability[], retryConfig?: IRetryConfig, appliance?: EnyoAppliance, useTls?: boolean, pvPowerSource?: SunspecPvPowerSource);
|
|
145
150
|
connect(): Promise<void>;
|
|
146
151
|
disconnect(): Promise<void>;
|
|
147
|
-
readData(clockId: string, resolution:
|
|
152
|
+
readData(clockId: string, resolution: EnyoDataBusMessageResolution): Promise<EnyoDataBusMessage[]>;
|
|
153
|
+
/**
|
|
154
|
+
* Guard the cumulative AC-energy reading before it is published as
|
|
155
|
+
* `meterValueWh`. The SunSpec `WH` register is an `acc32` (high word + low
|
|
156
|
+
* word) × 10^WH_SF; at a low-word rollover / wake-up the words can be
|
|
157
|
+
* mis-combined, so a poll jumps by exactly one 16-bit word
|
|
158
|
+
* (`65536 × 10^WH_SF`) up or down and back — Dirk Wasow's flip-flop of
|
|
159
|
+
* 6,553,600 Wh. A lifetime accumulator is also monotonic non-decreasing.
|
|
160
|
+
*
|
|
161
|
+
* So a reading is corrupt when it either DECREASES or JUMPS UP by ≥ half a
|
|
162
|
+
* register quantum (real per-poll production is orders of magnitude smaller):
|
|
163
|
+
* we republish the last good value rather than emit it (a raw `max-min`
|
|
164
|
+
* downstream would otherwise inflate it into ~a whole register word). A
|
|
165
|
+
* suspect level that persists for `AC_ENERGY_RESET_CONFIRM` consecutive polls
|
|
166
|
+
* is treated as a genuine reset/resync and adopted.
|
|
167
|
+
*
|
|
168
|
+
* Float models (111/112/113) report `WH` as an IEEE-754 float with no acc32
|
|
169
|
+
* word-boundary artifact; they leave `scaleFactor` undefined. For them there
|
|
170
|
+
* is no register quantum, so we enforce monotonicity only (reject decreases)
|
|
171
|
+
* and accept any increase — the ½-quantum upper bound applies to int+SF
|
|
172
|
+
* models (101/103) alone.
|
|
173
|
+
*/
|
|
174
|
+
private sanitizeAcEnergyWh;
|
|
148
175
|
/**
|
|
149
176
|
* Decode all active error bits from the inverter event registers into
|
|
150
177
|
* `EnyoApplianceErrorCode`s. Override in a subclass to customize the
|
|
@@ -189,7 +216,58 @@ export declare class SunspecInverter extends BaseSunspecDevice {
|
|
|
189
216
|
* returned (not undefined) so the field is cleared on the appliance.
|
|
190
217
|
*/
|
|
191
218
|
private computeActiveProductionLimitW;
|
|
219
|
+
/**
|
|
220
|
+
* Set the grid-operator power production (feed-in) limit on the inverter.
|
|
221
|
+
*
|
|
222
|
+
* Writes Model 123 `WMaxLimPct` + `WMaxLim_Ena` (as a percentage of the
|
|
223
|
+
* Model 121 `WMax` nameplate). Pass `null` to remove the limit and return
|
|
224
|
+
* the inverter to unthrottled production.
|
|
225
|
+
*
|
|
226
|
+
* The SDK exposes this so a consumer that receives a grid-operator
|
|
227
|
+
* production-limit command (from the data bus or elsewhere) can apply it;
|
|
228
|
+
* subscribing to and reacting to that command is the consumer's job.
|
|
229
|
+
*
|
|
230
|
+
* @param limitW - Maximum production power in Watts, or `null` to remove the limit
|
|
231
|
+
* @returns `true` if the write succeeded, `false` otherwise
|
|
232
|
+
*/
|
|
233
|
+
setPowerProductionLimit(limitW: number | null): Promise<boolean>;
|
|
234
|
+
/**
|
|
235
|
+
* Read the currently active grid-operator power production (feed-in) limit
|
|
236
|
+
* from the inverter, in Watts. Returns `null` when no limit is active, the
|
|
237
|
+
* registers cannot be read, or the configured limit is not actually
|
|
238
|
+
* throttling (limit ≥ `WMax`). See {@link computeActiveProductionLimitW}.
|
|
239
|
+
*/
|
|
240
|
+
getPowerProductionLimit(): Promise<number | null>;
|
|
192
241
|
private mapOperatingState;
|
|
242
|
+
/**
|
|
243
|
+
* PV production in Watt, sourced according to the configured `pvPowerSource`:
|
|
244
|
+
*
|
|
245
|
+
* - Auto (default): summed per-string MPPT DC power (Model 160) when strings are
|
|
246
|
+
* present — most granular, isolates PV — otherwise the inverter total via
|
|
247
|
+
* {@link inverterTotalPvPowerW} (Model 101 DCW, then AC). The fallback is only
|
|
248
|
+
* consulted when there are no strings, so inverters with working MPPT are
|
|
249
|
+
* unaffected. It lets a producing inverter that exposes no DC telemetry (e.g. an
|
|
250
|
+
* SMA Sunny Boy with Model 160 unreadable and DCW NOT_IMPLEMENTED) still report
|
|
251
|
+
* real production instead of 0 W.
|
|
252
|
+
* - Mppt: only the summed MPPT strings; a stringless inverter reports 0 W.
|
|
253
|
+
* - Inverter: only the inverter total (DCW, then AC); MPPT strings are ignored.
|
|
254
|
+
*
|
|
255
|
+
* Both inverter-total steps require a strictly positive value, so NOT_IMPLEMENTED
|
|
256
|
+
* DCW (decodes to 0) falls through to AC, and a negative AC reading (e.g. a hybrid
|
|
257
|
+
* importing from grid) falls through to 0 rather than reporting negative production.
|
|
258
|
+
* Edge case: in Auto/Inverter a hybrid discharging its battery while its MPPT is
|
|
259
|
+
* unreadable reports AC (incl. battery) rather than 0 — acceptable, and strictly
|
|
260
|
+
* better than reporting 0.
|
|
261
|
+
*/
|
|
262
|
+
protected selectPvPowerW(dcStrings: EnyoDataBusInverterValuesV1String[], inverterData: SunspecInverterData): {
|
|
263
|
+
pvPowerW: number;
|
|
264
|
+
source: string;
|
|
265
|
+
};
|
|
266
|
+
/**
|
|
267
|
+
* Inverter total PV power from Model 101: DCW when strictly positive, else AC when
|
|
268
|
+
* strictly positive, else 0. See {@link selectPvPowerW} for why positivity matters.
|
|
269
|
+
*/
|
|
270
|
+
private inverterTotalPvPowerW;
|
|
193
271
|
/**
|
|
194
272
|
* Map MPPT data to DC string structure for data bus
|
|
195
273
|
* Filters out battery-related strings (StCha 3, StDisCha 4)
|
|
@@ -336,7 +414,7 @@ export declare class SunspecBattery extends BaseSunspecDevice {
|
|
|
336
414
|
/**
|
|
337
415
|
* Update battery data and return data bus messages
|
|
338
416
|
*/
|
|
339
|
-
readData(clockId: string, resolution:
|
|
417
|
+
readData(clockId: string, resolution: EnyoDataBusMessageResolution): Promise<EnyoDataBusMessage[]>;
|
|
340
418
|
/**
|
|
341
419
|
* Extract battery power from MPPT strings with specific IDs
|
|
342
420
|
* StCha 3: Battery charging power (positive)
|
|
@@ -3,7 +3,7 @@
|
|
|
3
3
|
* SunSpec block interfaces with block numbers
|
|
4
4
|
*/
|
|
5
5
|
Object.defineProperty(exports, "__esModule", { value: true });
|
|
6
|
-
exports.SUNSPEC_CONTROLLABLE_FEATURES = exports.SunspecMeterCapability = exports.SunspecBatteryFeatureModeKind = exports.SunspecBatteryCapability = exports.SunspecInverterCapability = exports.SunspecStorageMode = exports.SunspecChargeSource = exports.SunspecVArPctMode = exports.SunspecEnableControl = exports.SunspecConnectionControl = exports.SunspecStorageControlMode = exports.SunspecBatteryEvent1 = exports.SunspecBatteryBankState = exports.SunspecBatteryType = exports.SunspecBatteryControlMode = exports.SunspecBatteryChargeState = exports.SunspecInverterOperatingState = exports.SunspecMPPTOperatingState = exports.SUNSPEC_CONNECTION_LOST_CODE = exports.SunspecInverterEvent1 = exports.SunspecModelId = exports.DEFAULT_RETRY_CONFIG = void 0;
|
|
6
|
+
exports.SUNSPEC_CONTROLLABLE_FEATURES = exports.SunspecMeterCapability = exports.SunspecBatteryFeatureModeKind = exports.SunspecBatteryCapability = exports.SunspecPvPowerSource = exports.SunspecInverterCapability = exports.SunspecStorageMode = exports.SunspecChargeSource = exports.SunspecVArPctMode = exports.SunspecEnableControl = exports.SunspecConnectionControl = exports.SunspecStorageControlMode = exports.SunspecBatteryEvent1 = exports.SunspecBatteryBankState = exports.SunspecBatteryType = exports.SunspecBatteryControlMode = exports.SunspecBatteryChargeState = exports.SunspecInverterOperatingState = exports.SunspecMPPTOperatingState = exports.SUNSPEC_CONNECTION_LOST_CODE = exports.SunspecInverterEvent1 = exports.SunspecModelId = exports.DEFAULT_RETRY_CONFIG = void 0;
|
|
7
7
|
const enyo_battery_appliance_js_1 = require("@enyo-energy/energy-app-sdk/dist/types/enyo-battery-appliance.js");
|
|
8
8
|
exports.DEFAULT_RETRY_CONFIG = {
|
|
9
9
|
phases: [
|
|
@@ -268,6 +268,20 @@ var SunspecInverterCapability;
|
|
|
268
268
|
(function (SunspecInverterCapability) {
|
|
269
269
|
SunspecInverterCapability["FeedInLimit"] = "feed-in-limit";
|
|
270
270
|
})(SunspecInverterCapability || (exports.SunspecInverterCapability = SunspecInverterCapability = {}));
|
|
271
|
+
/**
|
|
272
|
+
* Where an inverter's reported PV production (pvPowerW) is sourced from.
|
|
273
|
+
* - Auto: summed MPPT DC strings (Model 160) when present, else the inverter's
|
|
274
|
+
* total DC power (Model 101 DCW), else AC power (Model 101 W). Default.
|
|
275
|
+
* - Mppt: only summed MPPT DC strings; a stringless inverter reports 0 W.
|
|
276
|
+
* - Inverter: only the inverter total (DCW, then AC); MPPT strings are ignored.
|
|
277
|
+
* Use when Model 160 strings are unreliable but the inverter total is trusted.
|
|
278
|
+
*/
|
|
279
|
+
var SunspecPvPowerSource;
|
|
280
|
+
(function (SunspecPvPowerSource) {
|
|
281
|
+
SunspecPvPowerSource["Auto"] = "auto";
|
|
282
|
+
SunspecPvPowerSource["Mppt"] = "mppt";
|
|
283
|
+
SunspecPvPowerSource["Inverter"] = "inverter";
|
|
284
|
+
})(SunspecPvPowerSource || (exports.SunspecPvPowerSource = SunspecPvPowerSource = {}));
|
|
271
285
|
var SunspecBatteryCapability;
|
|
272
286
|
(function (SunspecBatteryCapability) {
|
|
273
287
|
SunspecBatteryCapability["GridCharging"] = "grid-charging";
|
|
@@ -124,6 +124,7 @@ export interface SunspecInverterData extends SunspecBlock {
|
|
|
124
124
|
reactivePower?: number;
|
|
125
125
|
powerFactor?: number;
|
|
126
126
|
acEnergy?: number;
|
|
127
|
+
acEnergyScaleFactor?: number;
|
|
127
128
|
dcCurrent?: number;
|
|
128
129
|
dcVoltage?: number;
|
|
129
130
|
dcPower?: number;
|
|
@@ -651,6 +652,19 @@ export declare enum SunspecStorageMode {
|
|
|
651
652
|
export declare enum SunspecInverterCapability {
|
|
652
653
|
FeedInLimit = "feed-in-limit"
|
|
653
654
|
}
|
|
655
|
+
/**
|
|
656
|
+
* Where an inverter's reported PV production (pvPowerW) is sourced from.
|
|
657
|
+
* - Auto: summed MPPT DC strings (Model 160) when present, else the inverter's
|
|
658
|
+
* total DC power (Model 101 DCW), else AC power (Model 101 W). Default.
|
|
659
|
+
* - Mppt: only summed MPPT DC strings; a stringless inverter reports 0 W.
|
|
660
|
+
* - Inverter: only the inverter total (DCW, then AC); MPPT strings are ignored.
|
|
661
|
+
* Use when Model 160 strings are unreliable but the inverter total is trusted.
|
|
662
|
+
*/
|
|
663
|
+
export declare enum SunspecPvPowerSource {
|
|
664
|
+
Auto = "auto",
|
|
665
|
+
Mppt = "mppt",
|
|
666
|
+
Inverter = "inverter"
|
|
667
|
+
}
|
|
654
668
|
export declare enum SunspecBatteryCapability {
|
|
655
669
|
GridCharging = "grid-charging",
|
|
656
670
|
DischargeLimit = "discharge-limit",
|
|
@@ -976,9 +976,11 @@ class SunspecModbusClient {
|
|
|
976
976
|
this.logRegisterRead(103, 50, 'Vendor Events 4', data.vendorEvents4, 'bitfield32');
|
|
977
977
|
const acEnergy = this.extractValue(buffer, 24, 'uint32', 2);
|
|
978
978
|
this.logRegisterRead(103, 24, 'AC Energy', acEnergy, 'acc32');
|
|
979
|
+
const whSf = this.isUnimplementedValue(scaleFactors.WH_SF, 'int16') ? 0 : scaleFactors.WH_SF;
|
|
979
980
|
data.acEnergy = !this.isUnimplementedValue(acEnergy, 'acc32')
|
|
980
|
-
? acEnergy * Math.pow(10,
|
|
981
|
+
? acEnergy * Math.pow(10, whSf)
|
|
981
982
|
: undefined;
|
|
983
|
+
data.acEnergyScaleFactor = whSf;
|
|
982
984
|
console.debug('[Model 103] Inverter Data:', data);
|
|
983
985
|
return data;
|
|
984
986
|
}
|
|
@@ -1038,9 +1040,11 @@ class SunspecModbusClient {
|
|
|
1038
1040
|
// Read AC Energy (32-bit accumulator) - Offset 24-25
|
|
1039
1041
|
const acEnergy = this.extractValue(buffer, 24, 'uint32', 2);
|
|
1040
1042
|
this.logRegisterRead(101, 24, 'AC Energy', acEnergy, 'acc32');
|
|
1043
|
+
const whSf = this.isUnimplementedValue(scaleFactors.WH_SF, 'int16') ? 0 : scaleFactors.WH_SF;
|
|
1041
1044
|
data.acEnergy = !this.isUnimplementedValue(acEnergy, 'acc32')
|
|
1042
|
-
? acEnergy * Math.pow(10,
|
|
1045
|
+
? acEnergy * Math.pow(10, whSf)
|
|
1043
1046
|
: undefined;
|
|
1047
|
+
data.acEnergyScaleFactor = whSf;
|
|
1044
1048
|
console.debug('[Model 101] Single Phase Inverter Data:', data);
|
|
1045
1049
|
return data;
|
|
1046
1050
|
}
|
package/dist/cjs/version.cjs
CHANGED
|
@@ -9,7 +9,7 @@ exports.getSdkVersion = getSdkVersion;
|
|
|
9
9
|
/**
|
|
10
10
|
* Current version of the enyo Energy App SDK.
|
|
11
11
|
*/
|
|
12
|
-
exports.SDK_VERSION = '0.0.
|
|
12
|
+
exports.SDK_VERSION = '0.0.96';
|
|
13
13
|
/**
|
|
14
14
|
* Gets the current SDK version.
|
|
15
15
|
* @returns The semantic version string of the SDK
|
package/dist/cjs/version.d.cts
CHANGED
|
@@ -1,4 +1,4 @@
|
|
|
1
|
-
import { type IRetryConfig, type SunspecBatteryBaseData, SunspecBatteryCapability, type SunspecBatteryControls, type SunspecBatteryData, type SunspecBatteryFeatureMode, type SunspecInverterData, SunspecInverterCapability, SunspecMeterCapability, type SunspecMPPTData, SunspecStorageMode } from "./sunspec-interfaces.js";
|
|
1
|
+
import { type IRetryConfig, type SunspecBatteryBaseData, SunspecBatteryCapability, type SunspecBatteryControls, type SunspecBatteryData, type SunspecBatteryFeatureMode, type SunspecInverterData, SunspecInverterCapability, SunspecPvPowerSource, SunspecMeterCapability, type SunspecMPPTData, SunspecStorageMode } from "./sunspec-interfaces.js";
|
|
2
2
|
import { ApplianceManager, EnergyApp } from "@enyo-energy/energy-app-sdk";
|
|
3
3
|
import { type EnyoAppliance, type EnyoApplianceErrorCode, EnyoApplianceName } from "@enyo-energy/energy-app-sdk/dist/types/enyo-appliance.js";
|
|
4
4
|
import { EnyoNetworkDevice } from "@enyo-energy/energy-app-sdk/dist/types/enyo-network-device.js";
|
|
@@ -127,6 +127,7 @@ export declare abstract class BaseSunspecDevice {
|
|
|
127
127
|
*/
|
|
128
128
|
export declare class SunspecInverter extends BaseSunspecDevice {
|
|
129
129
|
private readonly capabilities;
|
|
130
|
+
private readonly pvPowerSource;
|
|
130
131
|
/** Emit a connection-lost faulted status after this many consecutive failed reconnect attempts. */
|
|
131
132
|
private static readonly CONNECTION_FAULT_THRESHOLD;
|
|
132
133
|
/**
|
|
@@ -141,10 +142,36 @@ export declare class SunspecInverter extends BaseSunspecDevice {
|
|
|
141
142
|
private errorState;
|
|
142
143
|
private snapshotService?;
|
|
143
144
|
private statusReassertedThisSession;
|
|
144
|
-
|
|
145
|
+
private lastGoodAcEnergyWh?;
|
|
146
|
+
private acEnergyDropStreak;
|
|
147
|
+
/** Consecutive corrupt reads that confirm a genuine reset/resync (vs a transient glitch). */
|
|
148
|
+
private static readonly AC_ENERGY_RESET_CONFIRM;
|
|
149
|
+
constructor(energyApp: EnergyApp, name: EnyoApplianceName[], networkDevice: EnyoNetworkDevice, sunspecClient: SunspecModbusClient, applianceManager: ApplianceManager, unitId?: number, port?: number, baseAddress?: number, capabilities?: SunspecInverterCapability[], retryConfig?: IRetryConfig, appliance?: EnyoAppliance, useTls?: boolean, pvPowerSource?: SunspecPvPowerSource);
|
|
145
150
|
connect(): Promise<void>;
|
|
146
151
|
disconnect(): Promise<void>;
|
|
147
|
-
readData(clockId: string, resolution:
|
|
152
|
+
readData(clockId: string, resolution: EnyoDataBusMessageResolution): Promise<EnyoDataBusMessage[]>;
|
|
153
|
+
/**
|
|
154
|
+
* Guard the cumulative AC-energy reading before it is published as
|
|
155
|
+
* `meterValueWh`. The SunSpec `WH` register is an `acc32` (high word + low
|
|
156
|
+
* word) × 10^WH_SF; at a low-word rollover / wake-up the words can be
|
|
157
|
+
* mis-combined, so a poll jumps by exactly one 16-bit word
|
|
158
|
+
* (`65536 × 10^WH_SF`) up or down and back — Dirk Wasow's flip-flop of
|
|
159
|
+
* 6,553,600 Wh. A lifetime accumulator is also monotonic non-decreasing.
|
|
160
|
+
*
|
|
161
|
+
* So a reading is corrupt when it either DECREASES or JUMPS UP by ≥ half a
|
|
162
|
+
* register quantum (real per-poll production is orders of magnitude smaller):
|
|
163
|
+
* we republish the last good value rather than emit it (a raw `max-min`
|
|
164
|
+
* downstream would otherwise inflate it into ~a whole register word). A
|
|
165
|
+
* suspect level that persists for `AC_ENERGY_RESET_CONFIRM` consecutive polls
|
|
166
|
+
* is treated as a genuine reset/resync and adopted.
|
|
167
|
+
*
|
|
168
|
+
* Float models (111/112/113) report `WH` as an IEEE-754 float with no acc32
|
|
169
|
+
* word-boundary artifact; they leave `scaleFactor` undefined. For them there
|
|
170
|
+
* is no register quantum, so we enforce monotonicity only (reject decreases)
|
|
171
|
+
* and accept any increase — the ½-quantum upper bound applies to int+SF
|
|
172
|
+
* models (101/103) alone.
|
|
173
|
+
*/
|
|
174
|
+
private sanitizeAcEnergyWh;
|
|
148
175
|
/**
|
|
149
176
|
* Decode all active error bits from the inverter event registers into
|
|
150
177
|
* `EnyoApplianceErrorCode`s. Override in a subclass to customize the
|
|
@@ -189,7 +216,58 @@ export declare class SunspecInverter extends BaseSunspecDevice {
|
|
|
189
216
|
* returned (not undefined) so the field is cleared on the appliance.
|
|
190
217
|
*/
|
|
191
218
|
private computeActiveProductionLimitW;
|
|
219
|
+
/**
|
|
220
|
+
* Set the grid-operator power production (feed-in) limit on the inverter.
|
|
221
|
+
*
|
|
222
|
+
* Writes Model 123 `WMaxLimPct` + `WMaxLim_Ena` (as a percentage of the
|
|
223
|
+
* Model 121 `WMax` nameplate). Pass `null` to remove the limit and return
|
|
224
|
+
* the inverter to unthrottled production.
|
|
225
|
+
*
|
|
226
|
+
* The SDK exposes this so a consumer that receives a grid-operator
|
|
227
|
+
* production-limit command (from the data bus or elsewhere) can apply it;
|
|
228
|
+
* subscribing to and reacting to that command is the consumer's job.
|
|
229
|
+
*
|
|
230
|
+
* @param limitW - Maximum production power in Watts, or `null` to remove the limit
|
|
231
|
+
* @returns `true` if the write succeeded, `false` otherwise
|
|
232
|
+
*/
|
|
233
|
+
setPowerProductionLimit(limitW: number | null): Promise<boolean>;
|
|
234
|
+
/**
|
|
235
|
+
* Read the currently active grid-operator power production (feed-in) limit
|
|
236
|
+
* from the inverter, in Watts. Returns `null` when no limit is active, the
|
|
237
|
+
* registers cannot be read, or the configured limit is not actually
|
|
238
|
+
* throttling (limit ≥ `WMax`). See {@link computeActiveProductionLimitW}.
|
|
239
|
+
*/
|
|
240
|
+
getPowerProductionLimit(): Promise<number | null>;
|
|
192
241
|
private mapOperatingState;
|
|
242
|
+
/**
|
|
243
|
+
* PV production in Watt, sourced according to the configured `pvPowerSource`:
|
|
244
|
+
*
|
|
245
|
+
* - Auto (default): summed per-string MPPT DC power (Model 160) when strings are
|
|
246
|
+
* present — most granular, isolates PV — otherwise the inverter total via
|
|
247
|
+
* {@link inverterTotalPvPowerW} (Model 101 DCW, then AC). The fallback is only
|
|
248
|
+
* consulted when there are no strings, so inverters with working MPPT are
|
|
249
|
+
* unaffected. It lets a producing inverter that exposes no DC telemetry (e.g. an
|
|
250
|
+
* SMA Sunny Boy with Model 160 unreadable and DCW NOT_IMPLEMENTED) still report
|
|
251
|
+
* real production instead of 0 W.
|
|
252
|
+
* - Mppt: only the summed MPPT strings; a stringless inverter reports 0 W.
|
|
253
|
+
* - Inverter: only the inverter total (DCW, then AC); MPPT strings are ignored.
|
|
254
|
+
*
|
|
255
|
+
* Both inverter-total steps require a strictly positive value, so NOT_IMPLEMENTED
|
|
256
|
+
* DCW (decodes to 0) falls through to AC, and a negative AC reading (e.g. a hybrid
|
|
257
|
+
* importing from grid) falls through to 0 rather than reporting negative production.
|
|
258
|
+
* Edge case: in Auto/Inverter a hybrid discharging its battery while its MPPT is
|
|
259
|
+
* unreadable reports AC (incl. battery) rather than 0 — acceptable, and strictly
|
|
260
|
+
* better than reporting 0.
|
|
261
|
+
*/
|
|
262
|
+
protected selectPvPowerW(dcStrings: EnyoDataBusInverterValuesV1String[], inverterData: SunspecInverterData): {
|
|
263
|
+
pvPowerW: number;
|
|
264
|
+
source: string;
|
|
265
|
+
};
|
|
266
|
+
/**
|
|
267
|
+
* Inverter total PV power from Model 101: DCW when strictly positive, else AC when
|
|
268
|
+
* strictly positive, else 0. See {@link selectPvPowerW} for why positivity matters.
|
|
269
|
+
*/
|
|
270
|
+
private inverterTotalPvPowerW;
|
|
193
271
|
/**
|
|
194
272
|
* Map MPPT data to DC string structure for data bus
|
|
195
273
|
* Filters out battery-related strings (StCha 3, StDisCha 4)
|
|
@@ -336,7 +414,7 @@ export declare class SunspecBattery extends BaseSunspecDevice {
|
|
|
336
414
|
/**
|
|
337
415
|
* Update battery data and return data bus messages
|
|
338
416
|
*/
|
|
339
|
-
readData(clockId: string, resolution:
|
|
417
|
+
readData(clockId: string, resolution: EnyoDataBusMessageResolution): Promise<EnyoDataBusMessage[]>;
|
|
340
418
|
/**
|
|
341
419
|
* Extract battery power from MPPT strings with specific IDs
|
|
342
420
|
* StCha 3: Battery charging power (positive)
|
package/dist/sunspec-devices.js
CHANGED
|
@@ -1,4 +1,4 @@
|
|
|
1
|
-
import { SunspecBatteryChargeState, SunspecBatteryFeatureModeKind, SunspecEnableControl, SunspecInverterCapability, SunspecInverterEvent1, SunspecInverterOperatingState, SunspecModelId, SunspecMPPTOperatingState, SunspecStorageMode, SUNSPEC_CONNECTION_LOST_CODE } from "./sunspec-interfaces.js";
|
|
1
|
+
import { SunspecBatteryChargeState, SunspecBatteryFeatureModeKind, SunspecEnableControl, SunspecInverterCapability, SunspecPvPowerSource, SunspecInverterEvent1, SunspecInverterOperatingState, SunspecModelId, SunspecMPPTOperatingState, SunspecStorageMode, SUNSPEC_CONNECTION_LOST_CODE } from "./sunspec-interfaces.js";
|
|
2
2
|
import { randomUUID } from "node:crypto";
|
|
3
3
|
import { EnyoApplianceConnectionType, EnyoApplianceStateEnum, EnyoApplianceStatusEnum, EnyoApplianceTopologyFeatureEnum, EnyoApplianceTypeEnum } from "@enyo-energy/energy-app-sdk/dist/types/enyo-appliance.js";
|
|
4
4
|
import { ConnectionRetryManager } from "./connection-retry-manager.js";
|
|
@@ -334,6 +334,7 @@ export class BaseSunspecDevice {
|
|
|
334
334
|
*/
|
|
335
335
|
export class SunspecInverter extends BaseSunspecDevice {
|
|
336
336
|
capabilities;
|
|
337
|
+
pvPowerSource;
|
|
337
338
|
/** Emit a connection-lost faulted status after this many consecutive failed reconnect attempts. */
|
|
338
339
|
static CONNECTION_FAULT_THRESHOLD = 3;
|
|
339
340
|
/**
|
|
@@ -354,9 +355,23 @@ export class SunspecInverter extends BaseSunspecDevice {
|
|
|
354
355
|
// state reads healthy), so we force one re-assert of the current status on
|
|
355
356
|
// the first successful read of each session to converge the core.
|
|
356
357
|
statusReassertedThisSession = false;
|
|
357
|
-
|
|
358
|
+
// Last accepted cumulative AC-energy reading (Wh) and how many consecutive
|
|
359
|
+
// polls have reported a corrupt one (a decrease or a ≥½-register-quantum jump
|
|
360
|
+
// — the acc32 16-bit word-boundary artifact). See sanitizeAcEnergyWh.
|
|
361
|
+
lastGoodAcEnergyWh;
|
|
362
|
+
acEnergyDropStreak = 0;
|
|
363
|
+
/** Consecutive corrupt reads that confirm a genuine reset/resync (vs a transient glitch). */
|
|
364
|
+
static AC_ENERGY_RESET_CONFIRM = 3;
|
|
365
|
+
constructor(energyApp, name, networkDevice, sunspecClient, applianceManager, unitId = 1, port = 502, baseAddress = 40000, capabilities = [], retryConfig, appliance, useTls,
|
|
366
|
+
// Where pvPowerW is sourced from — see SunspecPvPowerSource. Defaults to
|
|
367
|
+
// Auto (MPPT strings, then Model 101 DCW/AC fallback). Use Mppt to report
|
|
368
|
+
// only summed MPPT strings, or Inverter to use only the inverter total —
|
|
369
|
+
// e.g. for devices whose Model 160 strings are unreliable or whose AC
|
|
370
|
+
// includes non-PV sources (a hybrid's battery discharge).
|
|
371
|
+
pvPowerSource = SunspecPvPowerSource.Auto) {
|
|
358
372
|
super(energyApp, name, networkDevice, sunspecClient, applianceManager, unitId, port, baseAddress, retryConfig, appliance, useTls);
|
|
359
373
|
this.capabilities = capabilities;
|
|
374
|
+
this.pvPowerSource = pvPowerSource;
|
|
360
375
|
}
|
|
361
376
|
async connect() {
|
|
362
377
|
// Ensure Sunspec client is connected
|
|
@@ -474,8 +489,8 @@ export class SunspecInverter extends BaseSunspecDevice {
|
|
|
474
489
|
// to Connected. No-op unless this device is still marked offline.
|
|
475
490
|
await this.reassertConnectedIfRecovered();
|
|
476
491
|
if (inverterData) {
|
|
477
|
-
const pvPowerW
|
|
478
|
-
console.debug(`Got PV Power from
|
|
492
|
+
const { pvPowerW, source: pvPowerSource } = this.selectPvPowerW(dcStrings, inverterData);
|
|
493
|
+
console.debug(`Got PV Power from ${pvPowerSource}: ${pvPowerW}W`);
|
|
479
494
|
const inverterMessage = {
|
|
480
495
|
id: randomUUID(),
|
|
481
496
|
message: EnyoDataBusMessageEnum.InverterValuesUpdateV1,
|
|
@@ -492,7 +507,7 @@ export class SunspecInverter extends BaseSunspecDevice {
|
|
|
492
507
|
voltageL1: inverterData.voltageAN || 0,
|
|
493
508
|
voltageL2: inverterData.voltageBN ?? undefined,
|
|
494
509
|
voltageL3: inverterData.voltageCN ?? undefined,
|
|
495
|
-
meterValueWh: inverterData.acEnergy,
|
|
510
|
+
meterValueWh: this.sanitizeAcEnergyWh(inverterData.acEnergy, inverterData.acEnergyScaleFactor),
|
|
496
511
|
strings: dcStrings
|
|
497
512
|
}
|
|
498
513
|
};
|
|
@@ -518,6 +533,54 @@ export class SunspecInverter extends BaseSunspecDevice {
|
|
|
518
533
|
}
|
|
519
534
|
return messages;
|
|
520
535
|
}
|
|
536
|
+
/**
|
|
537
|
+
* Guard the cumulative AC-energy reading before it is published as
|
|
538
|
+
* `meterValueWh`. The SunSpec `WH` register is an `acc32` (high word + low
|
|
539
|
+
* word) × 10^WH_SF; at a low-word rollover / wake-up the words can be
|
|
540
|
+
* mis-combined, so a poll jumps by exactly one 16-bit word
|
|
541
|
+
* (`65536 × 10^WH_SF`) up or down and back — Dirk Wasow's flip-flop of
|
|
542
|
+
* 6,553,600 Wh. A lifetime accumulator is also monotonic non-decreasing.
|
|
543
|
+
*
|
|
544
|
+
* So a reading is corrupt when it either DECREASES or JUMPS UP by ≥ half a
|
|
545
|
+
* register quantum (real per-poll production is orders of magnitude smaller):
|
|
546
|
+
* we republish the last good value rather than emit it (a raw `max-min`
|
|
547
|
+
* downstream would otherwise inflate it into ~a whole register word). A
|
|
548
|
+
* suspect level that persists for `AC_ENERGY_RESET_CONFIRM` consecutive polls
|
|
549
|
+
* is treated as a genuine reset/resync and adopted.
|
|
550
|
+
*
|
|
551
|
+
* Float models (111/112/113) report `WH` as an IEEE-754 float with no acc32
|
|
552
|
+
* word-boundary artifact; they leave `scaleFactor` undefined. For them there
|
|
553
|
+
* is no register quantum, so we enforce monotonicity only (reject decreases)
|
|
554
|
+
* and accept any increase — the ½-quantum upper bound applies to int+SF
|
|
555
|
+
* models (101/103) alone.
|
|
556
|
+
*/
|
|
557
|
+
sanitizeAcEnergyWh(raw, scaleFactor) {
|
|
558
|
+
if (raw == null)
|
|
559
|
+
return undefined;
|
|
560
|
+
if (this.lastGoodAcEnergyWh == null) {
|
|
561
|
+
this.lastGoodAcEnergyWh = raw;
|
|
562
|
+
this.acEnergyDropStreak = 0;
|
|
563
|
+
return raw;
|
|
564
|
+
}
|
|
565
|
+
const halfQuantumWh = scaleFactor != null ? 0.5 * 65536 * Math.pow(10, scaleFactor) : Infinity;
|
|
566
|
+
const delta = raw - this.lastGoodAcEnergyWh;
|
|
567
|
+
const plausible = delta >= 0 && delta < halfQuantumWh;
|
|
568
|
+
if (plausible) {
|
|
569
|
+
this.lastGoodAcEnergyWh = raw;
|
|
570
|
+
this.acEnergyDropStreak = 0;
|
|
571
|
+
return raw;
|
|
572
|
+
}
|
|
573
|
+
// A decrease or a ≥½-quantum jump — the acc32 word-boundary artifact.
|
|
574
|
+
this.acEnergyDropStreak++;
|
|
575
|
+
if (this.acEnergyDropStreak >= SunspecInverter.AC_ENERGY_RESET_CONFIRM) {
|
|
576
|
+
console.warn(`Notify_Devs: ${this.constructor.name} ${this.applianceId}: AC energy resync confirmed (${this.lastGoodAcEnergyWh} -> ${raw} Wh), adopting new baseline`);
|
|
577
|
+
this.lastGoodAcEnergyWh = raw;
|
|
578
|
+
this.acEnergyDropStreak = 0;
|
|
579
|
+
return raw;
|
|
580
|
+
}
|
|
581
|
+
console.warn(`Notify_Devs: ${this.constructor.name} ${this.applianceId}: rejecting corrupt AC energy reading ${raw} Wh (last good ${this.lastGoodAcEnergyWh} Wh, Δ=${delta}), republishing last good`);
|
|
582
|
+
return this.lastGoodAcEnergyWh;
|
|
583
|
+
}
|
|
521
584
|
/**
|
|
522
585
|
* Decode all active error bits from the inverter event registers into
|
|
523
586
|
* `EnyoApplianceErrorCode`s. Override in a subclass to customize the
|
|
@@ -705,6 +768,34 @@ export class SunspecInverter extends BaseSunspecDevice {
|
|
|
705
768
|
return null;
|
|
706
769
|
return limitW;
|
|
707
770
|
}
|
|
771
|
+
/**
|
|
772
|
+
* Set the grid-operator power production (feed-in) limit on the inverter.
|
|
773
|
+
*
|
|
774
|
+
* Writes Model 123 `WMaxLimPct` + `WMaxLim_Ena` (as a percentage of the
|
|
775
|
+
* Model 121 `WMax` nameplate). Pass `null` to remove the limit and return
|
|
776
|
+
* the inverter to unthrottled production.
|
|
777
|
+
*
|
|
778
|
+
* The SDK exposes this so a consumer that receives a grid-operator
|
|
779
|
+
* production-limit command (from the data bus or elsewhere) can apply it;
|
|
780
|
+
* subscribing to and reacting to that command is the consumer's job.
|
|
781
|
+
*
|
|
782
|
+
* @param limitW - Maximum production power in Watts, or `null` to remove the limit
|
|
783
|
+
* @returns `true` if the write succeeded, `false` otherwise
|
|
784
|
+
*/
|
|
785
|
+
async setPowerProductionLimit(limitW) {
|
|
786
|
+
return this.sunspecClient.setFeedInLimit(this.unitId, limitW);
|
|
787
|
+
}
|
|
788
|
+
/**
|
|
789
|
+
* Read the currently active grid-operator power production (feed-in) limit
|
|
790
|
+
* from the inverter, in Watts. Returns `null` when no limit is active, the
|
|
791
|
+
* registers cannot be read, or the configured limit is not actually
|
|
792
|
+
* throttling (limit ≥ `WMax`). See {@link computeActiveProductionLimitW}.
|
|
793
|
+
*/
|
|
794
|
+
async getPowerProductionLimit() {
|
|
795
|
+
const settings = await this.sunspecClient.readInverterSettings(this.unitId);
|
|
796
|
+
const controls = await this.sunspecClient.readInverterControls(this.unitId);
|
|
797
|
+
return this.computeActiveProductionLimitW(settings, controls);
|
|
798
|
+
}
|
|
708
799
|
mapOperatingState(state) {
|
|
709
800
|
if (!state)
|
|
710
801
|
return EnyoInverterStateEnum.Off;
|
|
@@ -720,6 +811,48 @@ export class SunspecInverter extends BaseSunspecDevice {
|
|
|
720
811
|
};
|
|
721
812
|
return stateMap[state] || EnyoInverterStateEnum.Off;
|
|
722
813
|
}
|
|
814
|
+
/**
|
|
815
|
+
* PV production in Watt, sourced according to the configured `pvPowerSource`:
|
|
816
|
+
*
|
|
817
|
+
* - Auto (default): summed per-string MPPT DC power (Model 160) when strings are
|
|
818
|
+
* present — most granular, isolates PV — otherwise the inverter total via
|
|
819
|
+
* {@link inverterTotalPvPowerW} (Model 101 DCW, then AC). The fallback is only
|
|
820
|
+
* consulted when there are no strings, so inverters with working MPPT are
|
|
821
|
+
* unaffected. It lets a producing inverter that exposes no DC telemetry (e.g. an
|
|
822
|
+
* SMA Sunny Boy with Model 160 unreadable and DCW NOT_IMPLEMENTED) still report
|
|
823
|
+
* real production instead of 0 W.
|
|
824
|
+
* - Mppt: only the summed MPPT strings; a stringless inverter reports 0 W.
|
|
825
|
+
* - Inverter: only the inverter total (DCW, then AC); MPPT strings are ignored.
|
|
826
|
+
*
|
|
827
|
+
* Both inverter-total steps require a strictly positive value, so NOT_IMPLEMENTED
|
|
828
|
+
* DCW (decodes to 0) falls through to AC, and a negative AC reading (e.g. a hybrid
|
|
829
|
+
* importing from grid) falls through to 0 rather than reporting negative production.
|
|
830
|
+
* Edge case: in Auto/Inverter a hybrid discharging its battery while its MPPT is
|
|
831
|
+
* unreadable reports AC (incl. battery) rather than 0 — acceptable, and strictly
|
|
832
|
+
* better than reporting 0.
|
|
833
|
+
*/
|
|
834
|
+
selectPvPowerW(dcStrings, inverterData) {
|
|
835
|
+
const stringSumW = dcStrings.reduce((sum, s) => sum + (s.powerW || 0), 0);
|
|
836
|
+
const useStrings = this.pvPowerSource === SunspecPvPowerSource.Mppt ||
|
|
837
|
+
(this.pvPowerSource === SunspecPvPowerSource.Auto && dcStrings.length > 0);
|
|
838
|
+
if (useStrings) {
|
|
839
|
+
return { pvPowerW: stringSumW, source: 'DC strings' };
|
|
840
|
+
}
|
|
841
|
+
return this.inverterTotalPvPowerW(inverterData);
|
|
842
|
+
}
|
|
843
|
+
/**
|
|
844
|
+
* Inverter total PV power from Model 101: DCW when strictly positive, else AC when
|
|
845
|
+
* strictly positive, else 0. See {@link selectPvPowerW} for why positivity matters.
|
|
846
|
+
*/
|
|
847
|
+
inverterTotalPvPowerW(inverterData) {
|
|
848
|
+
if (typeof inverterData.dcPower === 'number' && inverterData.dcPower > 0) {
|
|
849
|
+
return { pvPowerW: inverterData.dcPower, source: 'DC power (Model 101)' };
|
|
850
|
+
}
|
|
851
|
+
if (typeof inverterData.acPower === 'number' && inverterData.acPower > 0) {
|
|
852
|
+
return { pvPowerW: inverterData.acPower, source: 'AC power (Model 101)' };
|
|
853
|
+
}
|
|
854
|
+
return { pvPowerW: 0, source: 'none' };
|
|
855
|
+
}
|
|
723
856
|
/**
|
|
724
857
|
* Map MPPT data to DC string structure for data bus
|
|
725
858
|
* Filters out battery-related strings (StCha 3, StDisCha 4)
|
|
@@ -124,6 +124,7 @@ export interface SunspecInverterData extends SunspecBlock {
|
|
|
124
124
|
reactivePower?: number;
|
|
125
125
|
powerFactor?: number;
|
|
126
126
|
acEnergy?: number;
|
|
127
|
+
acEnergyScaleFactor?: number;
|
|
127
128
|
dcCurrent?: number;
|
|
128
129
|
dcVoltage?: number;
|
|
129
130
|
dcPower?: number;
|
|
@@ -651,6 +652,19 @@ export declare enum SunspecStorageMode {
|
|
|
651
652
|
export declare enum SunspecInverterCapability {
|
|
652
653
|
FeedInLimit = "feed-in-limit"
|
|
653
654
|
}
|
|
655
|
+
/**
|
|
656
|
+
* Where an inverter's reported PV production (pvPowerW) is sourced from.
|
|
657
|
+
* - Auto: summed MPPT DC strings (Model 160) when present, else the inverter's
|
|
658
|
+
* total DC power (Model 101 DCW), else AC power (Model 101 W). Default.
|
|
659
|
+
* - Mppt: only summed MPPT DC strings; a stringless inverter reports 0 W.
|
|
660
|
+
* - Inverter: only the inverter total (DCW, then AC); MPPT strings are ignored.
|
|
661
|
+
* Use when Model 160 strings are unreliable but the inverter total is trusted.
|
|
662
|
+
*/
|
|
663
|
+
export declare enum SunspecPvPowerSource {
|
|
664
|
+
Auto = "auto",
|
|
665
|
+
Mppt = "mppt",
|
|
666
|
+
Inverter = "inverter"
|
|
667
|
+
}
|
|
654
668
|
export declare enum SunspecBatteryCapability {
|
|
655
669
|
GridCharging = "grid-charging",
|
|
656
670
|
DischargeLimit = "discharge-limit",
|
|
@@ -265,6 +265,20 @@ export var SunspecInverterCapability;
|
|
|
265
265
|
(function (SunspecInverterCapability) {
|
|
266
266
|
SunspecInverterCapability["FeedInLimit"] = "feed-in-limit";
|
|
267
267
|
})(SunspecInverterCapability || (SunspecInverterCapability = {}));
|
|
268
|
+
/**
|
|
269
|
+
* Where an inverter's reported PV production (pvPowerW) is sourced from.
|
|
270
|
+
* - Auto: summed MPPT DC strings (Model 160) when present, else the inverter's
|
|
271
|
+
* total DC power (Model 101 DCW), else AC power (Model 101 W). Default.
|
|
272
|
+
* - Mppt: only summed MPPT DC strings; a stringless inverter reports 0 W.
|
|
273
|
+
* - Inverter: only the inverter total (DCW, then AC); MPPT strings are ignored.
|
|
274
|
+
* Use when Model 160 strings are unreliable but the inverter total is trusted.
|
|
275
|
+
*/
|
|
276
|
+
export var SunspecPvPowerSource;
|
|
277
|
+
(function (SunspecPvPowerSource) {
|
|
278
|
+
SunspecPvPowerSource["Auto"] = "auto";
|
|
279
|
+
SunspecPvPowerSource["Mppt"] = "mppt";
|
|
280
|
+
SunspecPvPowerSource["Inverter"] = "inverter";
|
|
281
|
+
})(SunspecPvPowerSource || (SunspecPvPowerSource = {}));
|
|
268
282
|
export var SunspecBatteryCapability;
|
|
269
283
|
(function (SunspecBatteryCapability) {
|
|
270
284
|
SunspecBatteryCapability["GridCharging"] = "grid-charging";
|
|
@@ -971,9 +971,11 @@ export class SunspecModbusClient {
|
|
|
971
971
|
this.logRegisterRead(103, 50, 'Vendor Events 4', data.vendorEvents4, 'bitfield32');
|
|
972
972
|
const acEnergy = this.extractValue(buffer, 24, 'uint32', 2);
|
|
973
973
|
this.logRegisterRead(103, 24, 'AC Energy', acEnergy, 'acc32');
|
|
974
|
+
const whSf = this.isUnimplementedValue(scaleFactors.WH_SF, 'int16') ? 0 : scaleFactors.WH_SF;
|
|
974
975
|
data.acEnergy = !this.isUnimplementedValue(acEnergy, 'acc32')
|
|
975
|
-
? acEnergy * Math.pow(10,
|
|
976
|
+
? acEnergy * Math.pow(10, whSf)
|
|
976
977
|
: undefined;
|
|
978
|
+
data.acEnergyScaleFactor = whSf;
|
|
977
979
|
console.debug('[Model 103] Inverter Data:', data);
|
|
978
980
|
return data;
|
|
979
981
|
}
|
|
@@ -1033,9 +1035,11 @@ export class SunspecModbusClient {
|
|
|
1033
1035
|
// Read AC Energy (32-bit accumulator) - Offset 24-25
|
|
1034
1036
|
const acEnergy = this.extractValue(buffer, 24, 'uint32', 2);
|
|
1035
1037
|
this.logRegisterRead(101, 24, 'AC Energy', acEnergy, 'acc32');
|
|
1038
|
+
const whSf = this.isUnimplementedValue(scaleFactors.WH_SF, 'int16') ? 0 : scaleFactors.WH_SF;
|
|
1036
1039
|
data.acEnergy = !this.isUnimplementedValue(acEnergy, 'acc32')
|
|
1037
|
-
? acEnergy * Math.pow(10,
|
|
1040
|
+
? acEnergy * Math.pow(10, whSf)
|
|
1038
1041
|
: undefined;
|
|
1042
|
+
data.acEnergyScaleFactor = whSf;
|
|
1039
1043
|
console.debug('[Model 101] Single Phase Inverter Data:', data);
|
|
1040
1044
|
return data;
|
|
1041
1045
|
}
|
package/dist/version.d.ts
CHANGED
package/dist/version.js
CHANGED
package/package.json
CHANGED
|
@@ -1,6 +1,6 @@
|
|
|
1
1
|
{
|
|
2
2
|
"name": "@enyo-energy/sunspec-sdk",
|
|
3
|
-
"version": "0.0.
|
|
3
|
+
"version": "0.0.96",
|
|
4
4
|
"description": "enyo Energy Sunspec SDK",
|
|
5
5
|
"type": "module",
|
|
6
6
|
"main": "dist/index.js",
|
|
@@ -41,7 +41,7 @@
|
|
|
41
41
|
},
|
|
42
42
|
"dependencies": {
|
|
43
43
|
"@enyo-energy/appliance-calibration": "0.0.2",
|
|
44
|
-
"@enyo-energy/energy-app-sdk": "^0.0.
|
|
44
|
+
"@enyo-energy/energy-app-sdk": "^0.0.175"
|
|
45
45
|
},
|
|
46
46
|
"volta": {
|
|
47
47
|
"node": "22.17.0"
|