@enyo-energy/sunspec-sdk 0.0.94 → 0.0.95
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/dist/cjs/sunspec-devices.cjs +53 -3
- package/dist/cjs/sunspec-devices.d.cts +32 -2
- package/dist/cjs/sunspec-interfaces.cjs +15 -1
- package/dist/cjs/sunspec-interfaces.d.cts +13 -0
- package/dist/cjs/version.cjs +1 -1
- package/dist/cjs/version.d.cts +1 -1
- package/dist/sunspec-devices.d.ts +32 -2
- package/dist/sunspec-devices.js +54 -4
- package/dist/sunspec-interfaces.d.ts +13 -0
- package/dist/sunspec-interfaces.js +14 -0
- package/dist/version.d.ts +1 -1
- package/dist/version.js +1 -1
- package/package.json +1 -1
|
@@ -341,6 +341,7 @@ exports.BaseSunspecDevice = BaseSunspecDevice;
|
|
|
341
341
|
*/
|
|
342
342
|
class SunspecInverter extends BaseSunspecDevice {
|
|
343
343
|
capabilities;
|
|
344
|
+
pvPowerSource;
|
|
344
345
|
/** Emit a connection-lost faulted status after this many consecutive failed reconnect attempts. */
|
|
345
346
|
static CONNECTION_FAULT_THRESHOLD = 3;
|
|
346
347
|
/**
|
|
@@ -361,9 +362,16 @@ class SunspecInverter extends BaseSunspecDevice {
|
|
|
361
362
|
// state reads healthy), so we force one re-assert of the current status on
|
|
362
363
|
// the first successful read of each session to converge the core.
|
|
363
364
|
statusReassertedThisSession = false;
|
|
364
|
-
constructor(energyApp, name, networkDevice, sunspecClient, applianceManager, unitId = 1, port = 502, baseAddress = 40000, capabilities = [], retryConfig, appliance, useTls
|
|
365
|
+
constructor(energyApp, name, networkDevice, sunspecClient, applianceManager, unitId = 1, port = 502, baseAddress = 40000, capabilities = [], retryConfig, appliance, useTls,
|
|
366
|
+
// Where pvPowerW is sourced from — see SunspecPvPowerSource. Defaults to
|
|
367
|
+
// Auto (MPPT strings, then Model 101 DCW/AC fallback). Use Mppt to report
|
|
368
|
+
// only summed MPPT strings, or Inverter to use only the inverter total —
|
|
369
|
+
// e.g. for devices whose Model 160 strings are unreliable or whose AC
|
|
370
|
+
// includes non-PV sources (a hybrid's battery discharge).
|
|
371
|
+
pvPowerSource = sunspec_interfaces_js_1.SunspecPvPowerSource.Auto) {
|
|
365
372
|
super(energyApp, name, networkDevice, sunspecClient, applianceManager, unitId, port, baseAddress, retryConfig, appliance, useTls);
|
|
366
373
|
this.capabilities = capabilities;
|
|
374
|
+
this.pvPowerSource = pvPowerSource;
|
|
367
375
|
}
|
|
368
376
|
async connect() {
|
|
369
377
|
// Ensure Sunspec client is connected
|
|
@@ -481,8 +489,8 @@ class SunspecInverter extends BaseSunspecDevice {
|
|
|
481
489
|
// to Connected. No-op unless this device is still marked offline.
|
|
482
490
|
await this.reassertConnectedIfRecovered();
|
|
483
491
|
if (inverterData) {
|
|
484
|
-
const pvPowerW
|
|
485
|
-
console.debug(`Got PV Power from
|
|
492
|
+
const { pvPowerW, source: pvPowerSource } = this.selectPvPowerW(dcStrings, inverterData);
|
|
493
|
+
console.debug(`Got PV Power from ${pvPowerSource}: ${pvPowerW}W`);
|
|
486
494
|
const inverterMessage = {
|
|
487
495
|
id: (0, node_crypto_1.randomUUID)(),
|
|
488
496
|
message: enyo_data_bus_value_js_1.EnyoDataBusMessageEnum.InverterValuesUpdateV1,
|
|
@@ -727,6 +735,48 @@ class SunspecInverter extends BaseSunspecDevice {
|
|
|
727
735
|
};
|
|
728
736
|
return stateMap[state] || enyo_data_bus_value_js_1.EnyoInverterStateEnum.Off;
|
|
729
737
|
}
|
|
738
|
+
/**
|
|
739
|
+
* PV production in Watt, sourced according to the configured `pvPowerSource`:
|
|
740
|
+
*
|
|
741
|
+
* - Auto (default): summed per-string MPPT DC power (Model 160) when strings are
|
|
742
|
+
* present — most granular, isolates PV — otherwise the inverter total via
|
|
743
|
+
* {@link inverterTotalPvPowerW} (Model 101 DCW, then AC). The fallback is only
|
|
744
|
+
* consulted when there are no strings, so inverters with working MPPT are
|
|
745
|
+
* unaffected. It lets a producing inverter that exposes no DC telemetry (e.g. an
|
|
746
|
+
* SMA Sunny Boy with Model 160 unreadable and DCW NOT_IMPLEMENTED) still report
|
|
747
|
+
* real production instead of 0 W.
|
|
748
|
+
* - Mppt: only the summed MPPT strings; a stringless inverter reports 0 W.
|
|
749
|
+
* - Inverter: only the inverter total (DCW, then AC); MPPT strings are ignored.
|
|
750
|
+
*
|
|
751
|
+
* Both inverter-total steps require a strictly positive value, so NOT_IMPLEMENTED
|
|
752
|
+
* DCW (decodes to 0) falls through to AC, and a negative AC reading (e.g. a hybrid
|
|
753
|
+
* importing from grid) falls through to 0 rather than reporting negative production.
|
|
754
|
+
* Edge case: in Auto/Inverter a hybrid discharging its battery while its MPPT is
|
|
755
|
+
* unreadable reports AC (incl. battery) rather than 0 — acceptable, and strictly
|
|
756
|
+
* better than reporting 0.
|
|
757
|
+
*/
|
|
758
|
+
selectPvPowerW(dcStrings, inverterData) {
|
|
759
|
+
const stringSumW = dcStrings.reduce((sum, s) => sum + (s.powerW || 0), 0);
|
|
760
|
+
const useStrings = this.pvPowerSource === sunspec_interfaces_js_1.SunspecPvPowerSource.Mppt ||
|
|
761
|
+
(this.pvPowerSource === sunspec_interfaces_js_1.SunspecPvPowerSource.Auto && dcStrings.length > 0);
|
|
762
|
+
if (useStrings) {
|
|
763
|
+
return { pvPowerW: stringSumW, source: 'DC strings' };
|
|
764
|
+
}
|
|
765
|
+
return this.inverterTotalPvPowerW(inverterData);
|
|
766
|
+
}
|
|
767
|
+
/**
|
|
768
|
+
* Inverter total PV power from Model 101: DCW when strictly positive, else AC when
|
|
769
|
+
* strictly positive, else 0. See {@link selectPvPowerW} for why positivity matters.
|
|
770
|
+
*/
|
|
771
|
+
inverterTotalPvPowerW(inverterData) {
|
|
772
|
+
if (typeof inverterData.dcPower === 'number' && inverterData.dcPower > 0) {
|
|
773
|
+
return { pvPowerW: inverterData.dcPower, source: 'DC power (Model 101)' };
|
|
774
|
+
}
|
|
775
|
+
if (typeof inverterData.acPower === 'number' && inverterData.acPower > 0) {
|
|
776
|
+
return { pvPowerW: inverterData.acPower, source: 'AC power (Model 101)' };
|
|
777
|
+
}
|
|
778
|
+
return { pvPowerW: 0, source: 'none' };
|
|
779
|
+
}
|
|
730
780
|
/**
|
|
731
781
|
* Map MPPT data to DC string structure for data bus
|
|
732
782
|
* Filters out battery-related strings (StCha 3, StDisCha 4)
|
|
@@ -1,4 +1,4 @@
|
|
|
1
|
-
import { type IRetryConfig, type SunspecBatteryBaseData, SunspecBatteryCapability, type SunspecBatteryControls, type SunspecBatteryData, type SunspecBatteryFeatureMode, type SunspecInverterData, SunspecInverterCapability, SunspecMeterCapability, type SunspecMPPTData, SunspecStorageMode } from "./sunspec-interfaces.cjs";
|
|
1
|
+
import { type IRetryConfig, type SunspecBatteryBaseData, SunspecBatteryCapability, type SunspecBatteryControls, type SunspecBatteryData, type SunspecBatteryFeatureMode, type SunspecInverterData, SunspecInverterCapability, SunspecPvPowerSource, SunspecMeterCapability, type SunspecMPPTData, SunspecStorageMode } from "./sunspec-interfaces.cjs";
|
|
2
2
|
import { ApplianceManager, EnergyApp } from "@enyo-energy/energy-app-sdk";
|
|
3
3
|
import { type EnyoAppliance, type EnyoApplianceErrorCode, EnyoApplianceName } from "@enyo-energy/energy-app-sdk/dist/types/enyo-appliance.js";
|
|
4
4
|
import { EnyoNetworkDevice } from "@enyo-energy/energy-app-sdk/dist/types/enyo-network-device.js";
|
|
@@ -127,6 +127,7 @@ export declare abstract class BaseSunspecDevice {
|
|
|
127
127
|
*/
|
|
128
128
|
export declare class SunspecInverter extends BaseSunspecDevice {
|
|
129
129
|
private readonly capabilities;
|
|
130
|
+
private readonly pvPowerSource;
|
|
130
131
|
/** Emit a connection-lost faulted status after this many consecutive failed reconnect attempts. */
|
|
131
132
|
private static readonly CONNECTION_FAULT_THRESHOLD;
|
|
132
133
|
/**
|
|
@@ -141,7 +142,7 @@ export declare class SunspecInverter extends BaseSunspecDevice {
|
|
|
141
142
|
private errorState;
|
|
142
143
|
private snapshotService?;
|
|
143
144
|
private statusReassertedThisSession;
|
|
144
|
-
constructor(energyApp: EnergyApp, name: EnyoApplianceName[], networkDevice: EnyoNetworkDevice, sunspecClient: SunspecModbusClient, applianceManager: ApplianceManager, unitId?: number, port?: number, baseAddress?: number, capabilities?: SunspecInverterCapability[], retryConfig?: IRetryConfig, appliance?: EnyoAppliance, useTls?: boolean);
|
|
145
|
+
constructor(energyApp: EnergyApp, name: EnyoApplianceName[], networkDevice: EnyoNetworkDevice, sunspecClient: SunspecModbusClient, applianceManager: ApplianceManager, unitId?: number, port?: number, baseAddress?: number, capabilities?: SunspecInverterCapability[], retryConfig?: IRetryConfig, appliance?: EnyoAppliance, useTls?: boolean, pvPowerSource?: SunspecPvPowerSource);
|
|
145
146
|
connect(): Promise<void>;
|
|
146
147
|
disconnect(): Promise<void>;
|
|
147
148
|
readData(clockId: string, resolution: '10s' | '30s' | '1m' | '15m'): Promise<EnyoDataBusMessage[]>;
|
|
@@ -190,6 +191,35 @@ export declare class SunspecInverter extends BaseSunspecDevice {
|
|
|
190
191
|
*/
|
|
191
192
|
private computeActiveProductionLimitW;
|
|
192
193
|
private mapOperatingState;
|
|
194
|
+
/**
|
|
195
|
+
* PV production in Watt, sourced according to the configured `pvPowerSource`:
|
|
196
|
+
*
|
|
197
|
+
* - Auto (default): summed per-string MPPT DC power (Model 160) when strings are
|
|
198
|
+
* present — most granular, isolates PV — otherwise the inverter total via
|
|
199
|
+
* {@link inverterTotalPvPowerW} (Model 101 DCW, then AC). The fallback is only
|
|
200
|
+
* consulted when there are no strings, so inverters with working MPPT are
|
|
201
|
+
* unaffected. It lets a producing inverter that exposes no DC telemetry (e.g. an
|
|
202
|
+
* SMA Sunny Boy with Model 160 unreadable and DCW NOT_IMPLEMENTED) still report
|
|
203
|
+
* real production instead of 0 W.
|
|
204
|
+
* - Mppt: only the summed MPPT strings; a stringless inverter reports 0 W.
|
|
205
|
+
* - Inverter: only the inverter total (DCW, then AC); MPPT strings are ignored.
|
|
206
|
+
*
|
|
207
|
+
* Both inverter-total steps require a strictly positive value, so NOT_IMPLEMENTED
|
|
208
|
+
* DCW (decodes to 0) falls through to AC, and a negative AC reading (e.g. a hybrid
|
|
209
|
+
* importing from grid) falls through to 0 rather than reporting negative production.
|
|
210
|
+
* Edge case: in Auto/Inverter a hybrid discharging its battery while its MPPT is
|
|
211
|
+
* unreadable reports AC (incl. battery) rather than 0 — acceptable, and strictly
|
|
212
|
+
* better than reporting 0.
|
|
213
|
+
*/
|
|
214
|
+
protected selectPvPowerW(dcStrings: EnyoDataBusInverterValuesV1String[], inverterData: SunspecInverterData): {
|
|
215
|
+
pvPowerW: number;
|
|
216
|
+
source: string;
|
|
217
|
+
};
|
|
218
|
+
/**
|
|
219
|
+
* Inverter total PV power from Model 101: DCW when strictly positive, else AC when
|
|
220
|
+
* strictly positive, else 0. See {@link selectPvPowerW} for why positivity matters.
|
|
221
|
+
*/
|
|
222
|
+
private inverterTotalPvPowerW;
|
|
193
223
|
/**
|
|
194
224
|
* Map MPPT data to DC string structure for data bus
|
|
195
225
|
* Filters out battery-related strings (StCha 3, StDisCha 4)
|
|
@@ -3,7 +3,7 @@
|
|
|
3
3
|
* SunSpec block interfaces with block numbers
|
|
4
4
|
*/
|
|
5
5
|
Object.defineProperty(exports, "__esModule", { value: true });
|
|
6
|
-
exports.SUNSPEC_CONTROLLABLE_FEATURES = exports.SunspecMeterCapability = exports.SunspecBatteryFeatureModeKind = exports.SunspecBatteryCapability = exports.SunspecInverterCapability = exports.SunspecStorageMode = exports.SunspecChargeSource = exports.SunspecVArPctMode = exports.SunspecEnableControl = exports.SunspecConnectionControl = exports.SunspecStorageControlMode = exports.SunspecBatteryEvent1 = exports.SunspecBatteryBankState = exports.SunspecBatteryType = exports.SunspecBatteryControlMode = exports.SunspecBatteryChargeState = exports.SunspecInverterOperatingState = exports.SunspecMPPTOperatingState = exports.SUNSPEC_CONNECTION_LOST_CODE = exports.SunspecInverterEvent1 = exports.SunspecModelId = exports.DEFAULT_RETRY_CONFIG = void 0;
|
|
6
|
+
exports.SUNSPEC_CONTROLLABLE_FEATURES = exports.SunspecMeterCapability = exports.SunspecBatteryFeatureModeKind = exports.SunspecBatteryCapability = exports.SunspecPvPowerSource = exports.SunspecInverterCapability = exports.SunspecStorageMode = exports.SunspecChargeSource = exports.SunspecVArPctMode = exports.SunspecEnableControl = exports.SunspecConnectionControl = exports.SunspecStorageControlMode = exports.SunspecBatteryEvent1 = exports.SunspecBatteryBankState = exports.SunspecBatteryType = exports.SunspecBatteryControlMode = exports.SunspecBatteryChargeState = exports.SunspecInverterOperatingState = exports.SunspecMPPTOperatingState = exports.SUNSPEC_CONNECTION_LOST_CODE = exports.SunspecInverterEvent1 = exports.SunspecModelId = exports.DEFAULT_RETRY_CONFIG = void 0;
|
|
7
7
|
const enyo_battery_appliance_js_1 = require("@enyo-energy/energy-app-sdk/dist/types/enyo-battery-appliance.js");
|
|
8
8
|
exports.DEFAULT_RETRY_CONFIG = {
|
|
9
9
|
phases: [
|
|
@@ -268,6 +268,20 @@ var SunspecInverterCapability;
|
|
|
268
268
|
(function (SunspecInverterCapability) {
|
|
269
269
|
SunspecInverterCapability["FeedInLimit"] = "feed-in-limit";
|
|
270
270
|
})(SunspecInverterCapability || (exports.SunspecInverterCapability = SunspecInverterCapability = {}));
|
|
271
|
+
/**
|
|
272
|
+
* Where an inverter's reported PV production (pvPowerW) is sourced from.
|
|
273
|
+
* - Auto: summed MPPT DC strings (Model 160) when present, else the inverter's
|
|
274
|
+
* total DC power (Model 101 DCW), else AC power (Model 101 W). Default.
|
|
275
|
+
* - Mppt: only summed MPPT DC strings; a stringless inverter reports 0 W.
|
|
276
|
+
* - Inverter: only the inverter total (DCW, then AC); MPPT strings are ignored.
|
|
277
|
+
* Use when Model 160 strings are unreliable but the inverter total is trusted.
|
|
278
|
+
*/
|
|
279
|
+
var SunspecPvPowerSource;
|
|
280
|
+
(function (SunspecPvPowerSource) {
|
|
281
|
+
SunspecPvPowerSource["Auto"] = "auto";
|
|
282
|
+
SunspecPvPowerSource["Mppt"] = "mppt";
|
|
283
|
+
SunspecPvPowerSource["Inverter"] = "inverter";
|
|
284
|
+
})(SunspecPvPowerSource || (exports.SunspecPvPowerSource = SunspecPvPowerSource = {}));
|
|
271
285
|
var SunspecBatteryCapability;
|
|
272
286
|
(function (SunspecBatteryCapability) {
|
|
273
287
|
SunspecBatteryCapability["GridCharging"] = "grid-charging";
|
|
@@ -651,6 +651,19 @@ export declare enum SunspecStorageMode {
|
|
|
651
651
|
export declare enum SunspecInverterCapability {
|
|
652
652
|
FeedInLimit = "feed-in-limit"
|
|
653
653
|
}
|
|
654
|
+
/**
|
|
655
|
+
* Where an inverter's reported PV production (pvPowerW) is sourced from.
|
|
656
|
+
* - Auto: summed MPPT DC strings (Model 160) when present, else the inverter's
|
|
657
|
+
* total DC power (Model 101 DCW), else AC power (Model 101 W). Default.
|
|
658
|
+
* - Mppt: only summed MPPT DC strings; a stringless inverter reports 0 W.
|
|
659
|
+
* - Inverter: only the inverter total (DCW, then AC); MPPT strings are ignored.
|
|
660
|
+
* Use when Model 160 strings are unreliable but the inverter total is trusted.
|
|
661
|
+
*/
|
|
662
|
+
export declare enum SunspecPvPowerSource {
|
|
663
|
+
Auto = "auto",
|
|
664
|
+
Mppt = "mppt",
|
|
665
|
+
Inverter = "inverter"
|
|
666
|
+
}
|
|
654
667
|
export declare enum SunspecBatteryCapability {
|
|
655
668
|
GridCharging = "grid-charging",
|
|
656
669
|
DischargeLimit = "discharge-limit",
|
package/dist/cjs/version.cjs
CHANGED
|
@@ -9,7 +9,7 @@ exports.getSdkVersion = getSdkVersion;
|
|
|
9
9
|
/**
|
|
10
10
|
* Current version of the enyo Energy App SDK.
|
|
11
11
|
*/
|
|
12
|
-
exports.SDK_VERSION = '0.0.
|
|
12
|
+
exports.SDK_VERSION = '0.0.95';
|
|
13
13
|
/**
|
|
14
14
|
* Gets the current SDK version.
|
|
15
15
|
* @returns The semantic version string of the SDK
|
package/dist/cjs/version.d.cts
CHANGED
|
@@ -1,4 +1,4 @@
|
|
|
1
|
-
import { type IRetryConfig, type SunspecBatteryBaseData, SunspecBatteryCapability, type SunspecBatteryControls, type SunspecBatteryData, type SunspecBatteryFeatureMode, type SunspecInverterData, SunspecInverterCapability, SunspecMeterCapability, type SunspecMPPTData, SunspecStorageMode } from "./sunspec-interfaces.js";
|
|
1
|
+
import { type IRetryConfig, type SunspecBatteryBaseData, SunspecBatteryCapability, type SunspecBatteryControls, type SunspecBatteryData, type SunspecBatteryFeatureMode, type SunspecInverterData, SunspecInverterCapability, SunspecPvPowerSource, SunspecMeterCapability, type SunspecMPPTData, SunspecStorageMode } from "./sunspec-interfaces.js";
|
|
2
2
|
import { ApplianceManager, EnergyApp } from "@enyo-energy/energy-app-sdk";
|
|
3
3
|
import { type EnyoAppliance, type EnyoApplianceErrorCode, EnyoApplianceName } from "@enyo-energy/energy-app-sdk/dist/types/enyo-appliance.js";
|
|
4
4
|
import { EnyoNetworkDevice } from "@enyo-energy/energy-app-sdk/dist/types/enyo-network-device.js";
|
|
@@ -127,6 +127,7 @@ export declare abstract class BaseSunspecDevice {
|
|
|
127
127
|
*/
|
|
128
128
|
export declare class SunspecInverter extends BaseSunspecDevice {
|
|
129
129
|
private readonly capabilities;
|
|
130
|
+
private readonly pvPowerSource;
|
|
130
131
|
/** Emit a connection-lost faulted status after this many consecutive failed reconnect attempts. */
|
|
131
132
|
private static readonly CONNECTION_FAULT_THRESHOLD;
|
|
132
133
|
/**
|
|
@@ -141,7 +142,7 @@ export declare class SunspecInverter extends BaseSunspecDevice {
|
|
|
141
142
|
private errorState;
|
|
142
143
|
private snapshotService?;
|
|
143
144
|
private statusReassertedThisSession;
|
|
144
|
-
constructor(energyApp: EnergyApp, name: EnyoApplianceName[], networkDevice: EnyoNetworkDevice, sunspecClient: SunspecModbusClient, applianceManager: ApplianceManager, unitId?: number, port?: number, baseAddress?: number, capabilities?: SunspecInverterCapability[], retryConfig?: IRetryConfig, appliance?: EnyoAppliance, useTls?: boolean);
|
|
145
|
+
constructor(energyApp: EnergyApp, name: EnyoApplianceName[], networkDevice: EnyoNetworkDevice, sunspecClient: SunspecModbusClient, applianceManager: ApplianceManager, unitId?: number, port?: number, baseAddress?: number, capabilities?: SunspecInverterCapability[], retryConfig?: IRetryConfig, appliance?: EnyoAppliance, useTls?: boolean, pvPowerSource?: SunspecPvPowerSource);
|
|
145
146
|
connect(): Promise<void>;
|
|
146
147
|
disconnect(): Promise<void>;
|
|
147
148
|
readData(clockId: string, resolution: '10s' | '30s' | '1m' | '15m'): Promise<EnyoDataBusMessage[]>;
|
|
@@ -190,6 +191,35 @@ export declare class SunspecInverter extends BaseSunspecDevice {
|
|
|
190
191
|
*/
|
|
191
192
|
private computeActiveProductionLimitW;
|
|
192
193
|
private mapOperatingState;
|
|
194
|
+
/**
|
|
195
|
+
* PV production in Watt, sourced according to the configured `pvPowerSource`:
|
|
196
|
+
*
|
|
197
|
+
* - Auto (default): summed per-string MPPT DC power (Model 160) when strings are
|
|
198
|
+
* present — most granular, isolates PV — otherwise the inverter total via
|
|
199
|
+
* {@link inverterTotalPvPowerW} (Model 101 DCW, then AC). The fallback is only
|
|
200
|
+
* consulted when there are no strings, so inverters with working MPPT are
|
|
201
|
+
* unaffected. It lets a producing inverter that exposes no DC telemetry (e.g. an
|
|
202
|
+
* SMA Sunny Boy with Model 160 unreadable and DCW NOT_IMPLEMENTED) still report
|
|
203
|
+
* real production instead of 0 W.
|
|
204
|
+
* - Mppt: only the summed MPPT strings; a stringless inverter reports 0 W.
|
|
205
|
+
* - Inverter: only the inverter total (DCW, then AC); MPPT strings are ignored.
|
|
206
|
+
*
|
|
207
|
+
* Both inverter-total steps require a strictly positive value, so NOT_IMPLEMENTED
|
|
208
|
+
* DCW (decodes to 0) falls through to AC, and a negative AC reading (e.g. a hybrid
|
|
209
|
+
* importing from grid) falls through to 0 rather than reporting negative production.
|
|
210
|
+
* Edge case: in Auto/Inverter a hybrid discharging its battery while its MPPT is
|
|
211
|
+
* unreadable reports AC (incl. battery) rather than 0 — acceptable, and strictly
|
|
212
|
+
* better than reporting 0.
|
|
213
|
+
*/
|
|
214
|
+
protected selectPvPowerW(dcStrings: EnyoDataBusInverterValuesV1String[], inverterData: SunspecInverterData): {
|
|
215
|
+
pvPowerW: number;
|
|
216
|
+
source: string;
|
|
217
|
+
};
|
|
218
|
+
/**
|
|
219
|
+
* Inverter total PV power from Model 101: DCW when strictly positive, else AC when
|
|
220
|
+
* strictly positive, else 0. See {@link selectPvPowerW} for why positivity matters.
|
|
221
|
+
*/
|
|
222
|
+
private inverterTotalPvPowerW;
|
|
193
223
|
/**
|
|
194
224
|
* Map MPPT data to DC string structure for data bus
|
|
195
225
|
* Filters out battery-related strings (StCha 3, StDisCha 4)
|
package/dist/sunspec-devices.js
CHANGED
|
@@ -1,4 +1,4 @@
|
|
|
1
|
-
import { SunspecBatteryChargeState, SunspecBatteryFeatureModeKind, SunspecEnableControl, SunspecInverterCapability, SunspecInverterEvent1, SunspecInverterOperatingState, SunspecModelId, SunspecMPPTOperatingState, SunspecStorageMode, SUNSPEC_CONNECTION_LOST_CODE } from "./sunspec-interfaces.js";
|
|
1
|
+
import { SunspecBatteryChargeState, SunspecBatteryFeatureModeKind, SunspecEnableControl, SunspecInverterCapability, SunspecPvPowerSource, SunspecInverterEvent1, SunspecInverterOperatingState, SunspecModelId, SunspecMPPTOperatingState, SunspecStorageMode, SUNSPEC_CONNECTION_LOST_CODE } from "./sunspec-interfaces.js";
|
|
2
2
|
import { randomUUID } from "node:crypto";
|
|
3
3
|
import { EnyoApplianceConnectionType, EnyoApplianceStateEnum, EnyoApplianceStatusEnum, EnyoApplianceTopologyFeatureEnum, EnyoApplianceTypeEnum } from "@enyo-energy/energy-app-sdk/dist/types/enyo-appliance.js";
|
|
4
4
|
import { ConnectionRetryManager } from "./connection-retry-manager.js";
|
|
@@ -334,6 +334,7 @@ export class BaseSunspecDevice {
|
|
|
334
334
|
*/
|
|
335
335
|
export class SunspecInverter extends BaseSunspecDevice {
|
|
336
336
|
capabilities;
|
|
337
|
+
pvPowerSource;
|
|
337
338
|
/** Emit a connection-lost faulted status after this many consecutive failed reconnect attempts. */
|
|
338
339
|
static CONNECTION_FAULT_THRESHOLD = 3;
|
|
339
340
|
/**
|
|
@@ -354,9 +355,16 @@ export class SunspecInverter extends BaseSunspecDevice {
|
|
|
354
355
|
// state reads healthy), so we force one re-assert of the current status on
|
|
355
356
|
// the first successful read of each session to converge the core.
|
|
356
357
|
statusReassertedThisSession = false;
|
|
357
|
-
constructor(energyApp, name, networkDevice, sunspecClient, applianceManager, unitId = 1, port = 502, baseAddress = 40000, capabilities = [], retryConfig, appliance, useTls
|
|
358
|
+
constructor(energyApp, name, networkDevice, sunspecClient, applianceManager, unitId = 1, port = 502, baseAddress = 40000, capabilities = [], retryConfig, appliance, useTls,
|
|
359
|
+
// Where pvPowerW is sourced from — see SunspecPvPowerSource. Defaults to
|
|
360
|
+
// Auto (MPPT strings, then Model 101 DCW/AC fallback). Use Mppt to report
|
|
361
|
+
// only summed MPPT strings, or Inverter to use only the inverter total —
|
|
362
|
+
// e.g. for devices whose Model 160 strings are unreliable or whose AC
|
|
363
|
+
// includes non-PV sources (a hybrid's battery discharge).
|
|
364
|
+
pvPowerSource = SunspecPvPowerSource.Auto) {
|
|
358
365
|
super(energyApp, name, networkDevice, sunspecClient, applianceManager, unitId, port, baseAddress, retryConfig, appliance, useTls);
|
|
359
366
|
this.capabilities = capabilities;
|
|
367
|
+
this.pvPowerSource = pvPowerSource;
|
|
360
368
|
}
|
|
361
369
|
async connect() {
|
|
362
370
|
// Ensure Sunspec client is connected
|
|
@@ -474,8 +482,8 @@ export class SunspecInverter extends BaseSunspecDevice {
|
|
|
474
482
|
// to Connected. No-op unless this device is still marked offline.
|
|
475
483
|
await this.reassertConnectedIfRecovered();
|
|
476
484
|
if (inverterData) {
|
|
477
|
-
const pvPowerW
|
|
478
|
-
console.debug(`Got PV Power from
|
|
485
|
+
const { pvPowerW, source: pvPowerSource } = this.selectPvPowerW(dcStrings, inverterData);
|
|
486
|
+
console.debug(`Got PV Power from ${pvPowerSource}: ${pvPowerW}W`);
|
|
479
487
|
const inverterMessage = {
|
|
480
488
|
id: randomUUID(),
|
|
481
489
|
message: EnyoDataBusMessageEnum.InverterValuesUpdateV1,
|
|
@@ -720,6 +728,48 @@ export class SunspecInverter extends BaseSunspecDevice {
|
|
|
720
728
|
};
|
|
721
729
|
return stateMap[state] || EnyoInverterStateEnum.Off;
|
|
722
730
|
}
|
|
731
|
+
/**
|
|
732
|
+
* PV production in Watt, sourced according to the configured `pvPowerSource`:
|
|
733
|
+
*
|
|
734
|
+
* - Auto (default): summed per-string MPPT DC power (Model 160) when strings are
|
|
735
|
+
* present — most granular, isolates PV — otherwise the inverter total via
|
|
736
|
+
* {@link inverterTotalPvPowerW} (Model 101 DCW, then AC). The fallback is only
|
|
737
|
+
* consulted when there are no strings, so inverters with working MPPT are
|
|
738
|
+
* unaffected. It lets a producing inverter that exposes no DC telemetry (e.g. an
|
|
739
|
+
* SMA Sunny Boy with Model 160 unreadable and DCW NOT_IMPLEMENTED) still report
|
|
740
|
+
* real production instead of 0 W.
|
|
741
|
+
* - Mppt: only the summed MPPT strings; a stringless inverter reports 0 W.
|
|
742
|
+
* - Inverter: only the inverter total (DCW, then AC); MPPT strings are ignored.
|
|
743
|
+
*
|
|
744
|
+
* Both inverter-total steps require a strictly positive value, so NOT_IMPLEMENTED
|
|
745
|
+
* DCW (decodes to 0) falls through to AC, and a negative AC reading (e.g. a hybrid
|
|
746
|
+
* importing from grid) falls through to 0 rather than reporting negative production.
|
|
747
|
+
* Edge case: in Auto/Inverter a hybrid discharging its battery while its MPPT is
|
|
748
|
+
* unreadable reports AC (incl. battery) rather than 0 — acceptable, and strictly
|
|
749
|
+
* better than reporting 0.
|
|
750
|
+
*/
|
|
751
|
+
selectPvPowerW(dcStrings, inverterData) {
|
|
752
|
+
const stringSumW = dcStrings.reduce((sum, s) => sum + (s.powerW || 0), 0);
|
|
753
|
+
const useStrings = this.pvPowerSource === SunspecPvPowerSource.Mppt ||
|
|
754
|
+
(this.pvPowerSource === SunspecPvPowerSource.Auto && dcStrings.length > 0);
|
|
755
|
+
if (useStrings) {
|
|
756
|
+
return { pvPowerW: stringSumW, source: 'DC strings' };
|
|
757
|
+
}
|
|
758
|
+
return this.inverterTotalPvPowerW(inverterData);
|
|
759
|
+
}
|
|
760
|
+
/**
|
|
761
|
+
* Inverter total PV power from Model 101: DCW when strictly positive, else AC when
|
|
762
|
+
* strictly positive, else 0. See {@link selectPvPowerW} for why positivity matters.
|
|
763
|
+
*/
|
|
764
|
+
inverterTotalPvPowerW(inverterData) {
|
|
765
|
+
if (typeof inverterData.dcPower === 'number' && inverterData.dcPower > 0) {
|
|
766
|
+
return { pvPowerW: inverterData.dcPower, source: 'DC power (Model 101)' };
|
|
767
|
+
}
|
|
768
|
+
if (typeof inverterData.acPower === 'number' && inverterData.acPower > 0) {
|
|
769
|
+
return { pvPowerW: inverterData.acPower, source: 'AC power (Model 101)' };
|
|
770
|
+
}
|
|
771
|
+
return { pvPowerW: 0, source: 'none' };
|
|
772
|
+
}
|
|
723
773
|
/**
|
|
724
774
|
* Map MPPT data to DC string structure for data bus
|
|
725
775
|
* Filters out battery-related strings (StCha 3, StDisCha 4)
|
|
@@ -651,6 +651,19 @@ export declare enum SunspecStorageMode {
|
|
|
651
651
|
export declare enum SunspecInverterCapability {
|
|
652
652
|
FeedInLimit = "feed-in-limit"
|
|
653
653
|
}
|
|
654
|
+
/**
|
|
655
|
+
* Where an inverter's reported PV production (pvPowerW) is sourced from.
|
|
656
|
+
* - Auto: summed MPPT DC strings (Model 160) when present, else the inverter's
|
|
657
|
+
* total DC power (Model 101 DCW), else AC power (Model 101 W). Default.
|
|
658
|
+
* - Mppt: only summed MPPT DC strings; a stringless inverter reports 0 W.
|
|
659
|
+
* - Inverter: only the inverter total (DCW, then AC); MPPT strings are ignored.
|
|
660
|
+
* Use when Model 160 strings are unreliable but the inverter total is trusted.
|
|
661
|
+
*/
|
|
662
|
+
export declare enum SunspecPvPowerSource {
|
|
663
|
+
Auto = "auto",
|
|
664
|
+
Mppt = "mppt",
|
|
665
|
+
Inverter = "inverter"
|
|
666
|
+
}
|
|
654
667
|
export declare enum SunspecBatteryCapability {
|
|
655
668
|
GridCharging = "grid-charging",
|
|
656
669
|
DischargeLimit = "discharge-limit",
|
|
@@ -265,6 +265,20 @@ export var SunspecInverterCapability;
|
|
|
265
265
|
(function (SunspecInverterCapability) {
|
|
266
266
|
SunspecInverterCapability["FeedInLimit"] = "feed-in-limit";
|
|
267
267
|
})(SunspecInverterCapability || (SunspecInverterCapability = {}));
|
|
268
|
+
/**
|
|
269
|
+
* Where an inverter's reported PV production (pvPowerW) is sourced from.
|
|
270
|
+
* - Auto: summed MPPT DC strings (Model 160) when present, else the inverter's
|
|
271
|
+
* total DC power (Model 101 DCW), else AC power (Model 101 W). Default.
|
|
272
|
+
* - Mppt: only summed MPPT DC strings; a stringless inverter reports 0 W.
|
|
273
|
+
* - Inverter: only the inverter total (DCW, then AC); MPPT strings are ignored.
|
|
274
|
+
* Use when Model 160 strings are unreliable but the inverter total is trusted.
|
|
275
|
+
*/
|
|
276
|
+
export var SunspecPvPowerSource;
|
|
277
|
+
(function (SunspecPvPowerSource) {
|
|
278
|
+
SunspecPvPowerSource["Auto"] = "auto";
|
|
279
|
+
SunspecPvPowerSource["Mppt"] = "mppt";
|
|
280
|
+
SunspecPvPowerSource["Inverter"] = "inverter";
|
|
281
|
+
})(SunspecPvPowerSource || (SunspecPvPowerSource = {}));
|
|
268
282
|
export var SunspecBatteryCapability;
|
|
269
283
|
(function (SunspecBatteryCapability) {
|
|
270
284
|
SunspecBatteryCapability["GridCharging"] = "grid-charging";
|
package/dist/version.d.ts
CHANGED
package/dist/version.js
CHANGED