@enyo-energy/sunspec-sdk 0.0.74 → 0.0.76

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
@@ -2,6 +2,7 @@
2
2
  Object.defineProperty(exports, "__esModule", { value: true });
3
3
  exports.SunspecMeter = exports.SunspecBattery = exports.SunspecInverter = exports.BaseSunspecDevice = void 0;
4
4
  exports.detectFeaturesFromRegisters = detectFeaturesFromRegisters;
5
+ exports.selectLiveBatteryPowerW = selectLiveBatteryPowerW;
5
6
  exports.filterFeaturesByCalibrationResult = filterFeaturesByCalibrationResult;
6
7
  const sunspec_interfaces_js_1 = require("./sunspec-interfaces.cjs");
7
8
  const node_crypto_1 = require("node:crypto");
@@ -711,8 +712,6 @@ class SunspecInverter extends BaseSunspecDevice {
711
712
  this.dataBus = this.energyApp.useDataBus();
712
713
  this.dataBusListenerId = this.dataBus.listenForMessages([
713
714
  enyo_data_bus_value_js_1.EnyoDataBusMessageEnum.SetInverterFeedInLimitV1,
714
- enyo_data_bus_value_js_1.EnyoDataBusMessageEnum.StartCalibrationV1,
715
- enyo_data_bus_value_js_1.EnyoDataBusMessageEnum.StopCalibrationV1,
716
715
  ], (entry) => this.handleInverterCommand(entry));
717
716
  console.log(`Inverter ${this.applianceId}: started data bus listening (listener ${this.dataBusListenerId})`);
718
717
  }
@@ -737,12 +736,6 @@ class SunspecInverter extends BaseSunspecDevice {
737
736
  case enyo_data_bus_value_js_1.EnyoDataBusMessageEnum.SetInverterFeedInLimitV1:
738
737
  await this.handleSetFeedInLimit(entry);
739
738
  break;
740
- case enyo_data_bus_value_js_1.EnyoDataBusMessageEnum.StartCalibrationV1:
741
- await this.handleStartCalibration(entry);
742
- break;
743
- case enyo_data_bus_value_js_1.EnyoDataBusMessageEnum.StopCalibrationV1:
744
- await this.handleStopCalibration(entry);
745
- break;
746
739
  }
747
740
  }
748
741
  catch (error) {
@@ -788,51 +781,6 @@ class SunspecInverter extends BaseSunspecDevice {
788
781
  await this.snapshotService.initialize();
789
782
  console.log(`Inverter ${this.applianceId}: snapshot service initialized`);
790
783
  }
791
- async handleStartCalibration(msg) {
792
- if (!this.isConnected() || !this.applianceId) {
793
- this.sendCommandAcknowledge(msg.id, msg.message, enyo_data_bus_value_js_1.EnyoCommandAcknowledgeAnswerEnum.Rejected, 'Not connected');
794
- return;
795
- }
796
- if (!this.snapshotService) {
797
- await this.initSnapshotService();
798
- }
799
- if (!this.snapshotService) {
800
- this.sendCommandAcknowledge(msg.id, msg.message, enyo_data_bus_value_js_1.EnyoCommandAcknowledgeAnswerEnum.Rejected, 'Snapshot service unavailable');
801
- return;
802
- }
803
- if (this.snapshotService.isCalibrating()) {
804
- console.log(`Inverter ${this.applianceId}: calibration already active — ack idempotently`);
805
- this.sendCommandAcknowledge(msg.id, msg.message, enyo_data_bus_value_js_1.EnyoCommandAcknowledgeAnswerEnum.Accepted);
806
- return;
807
- }
808
- console.log(`Inverter ${this.applianceId}: handling StartCalibrationV1`);
809
- const controls = await this.sunspecClient.readInverterControls(this.unitId);
810
- if (!controls) {
811
- this.sendCommandAcknowledge(msg.id, msg.message, enyo_data_bus_value_js_1.EnyoCommandAcknowledgeAnswerEnum.Rejected, 'Failed to read inverter controls for snapshot');
812
- return;
813
- }
814
- try {
815
- await this.snapshotService.startCalibration(controls);
816
- }
817
- catch (error) {
818
- this.sendCommandAcknowledge(msg.id, msg.message, enyo_data_bus_value_js_1.EnyoCommandAcknowledgeAnswerEnum.Rejected, `Failed to persist snapshot: ${error}`);
819
- return;
820
- }
821
- this.sendCommandAcknowledge(msg.id, msg.message, enyo_data_bus_value_js_1.EnyoCommandAcknowledgeAnswerEnum.Accepted);
822
- }
823
- async handleStopCalibration(msg) {
824
- if (!this.applianceId) {
825
- this.sendCommandAcknowledge(msg.id, msg.message, enyo_data_bus_value_js_1.EnyoCommandAcknowledgeAnswerEnum.Rejected, 'Not initialized');
826
- return;
827
- }
828
- console.log(`Inverter ${this.applianceId}: handling StopCalibrationV1`);
829
- // SnapshotService.stopCalibration fires `restoreInverterSnapshot` internally with
830
- // reason="stop" before returning. Any restore failure is logged by the callback
831
- // (the persisted snapshot is already gone by then — see library notes) so we
832
- // always ack Accepted from here.
833
- await this.snapshotService?.stopCalibration();
834
- this.sendCommandAcknowledge(msg.id, msg.message, enyo_data_bus_value_js_1.EnyoCommandAcknowledgeAnswerEnum.Accepted);
835
- }
836
784
  /**
837
785
  * `onRestore` callback for the inverter's {@link SnapshotService}. Writes only the
838
786
  * subset of writable inverter fields that other commands actually touched during the
@@ -905,6 +853,35 @@ function detectFeaturesFromRegisters(batteryData) {
905
853
  * the full detected set to preserve the old all-or-nothing semantics on
906
854
  * upgrade.
907
855
  */
856
+ /**
857
+ * Pick the live battery power, in preference order:
858
+ *
859
+ * 1. Model 160 (MPPT) `StCha 3` / `StDisCha 4` — direct DC-link reading,
860
+ * passed in as the already-summed `mpptBatteryPowerW`.
861
+ * 2. Model 802 `w` (offset 47) — surfaced as `chargePower` / `dischargePower`
862
+ * by the Model 802 path of `SunspecModbusClient.readBatteryData`.
863
+ * 3. `undefined` — no reliable live source on this device.
864
+ *
865
+ * The Model 124 path of `readBatteryData` no longer manufactures
866
+ * `chargePower` / `dischargePower` from `inWRte × wChaMax` (a commanded rate
867
+ * cap, not a live measurement). So whenever this function sees
868
+ * `chargePower` / `dischargePower` defined, they came from Model 802.
869
+ *
870
+ * Exported as a free function so the preference logic can be unit-tested
871
+ * without the full `SunspecBattery` scaffold.
872
+ */
873
+ function selectLiveBatteryPowerW(mpptBatteryPowerW, batteryData) {
874
+ if (mpptBatteryPowerW !== undefined) {
875
+ return mpptBatteryPowerW;
876
+ }
877
+ if (!batteryData) {
878
+ return undefined;
879
+ }
880
+ if (batteryData.chargePower === undefined && batteryData.dischargePower === undefined) {
881
+ return undefined;
882
+ }
883
+ return (batteryData.chargePower ?? 0) - (batteryData.dischargePower ?? 0);
884
+ }
908
885
  function filterFeaturesByCalibrationResult(detected, result, controllable) {
909
886
  if (!result || result.state !== 'calibrated') {
910
887
  return detected.filter(f => !controllable.includes(f));
@@ -1168,17 +1145,8 @@ class SunspecBattery extends BaseSunspecDevice {
1168
1145
  return messages;
1169
1146
  }
1170
1147
  if (batteryData) {
1171
- const advancedBatteryModel = this.sunspecClient.findModel(this.unitId, 801);
1172
- const batteryBaseModel = this.sunspecClient.findModel(this.unitId, sunspec_interfaces_js_1.SunspecModelId.BatteryBase);
1173
- // Determine battery power: prefer model 802 w field, then MPPT extraction, then undefined
1174
- let batteryPowerW;
1175
- if (batteryBaseModel && (batteryData.chargePower !== undefined || batteryData.dischargePower !== undefined)) {
1176
- // Model 802 provides power directly: positive = charge, negative = discharge
1177
- batteryPowerW = (batteryData.chargePower || 0) - (batteryData.dischargePower || 0);
1178
- }
1179
- else if (!advancedBatteryModel) {
1180
- batteryPowerW = mpptBatteryPowerW;
1181
- }
1148
+ // See `selectLiveBatteryPowerW` for the source-preference rationale.
1149
+ const batteryPowerW = selectLiveBatteryPowerW(mpptBatteryPowerW, batteryData);
1182
1150
  // Feed the calibration driver's synchronous power cache. No-op when calibration
1183
1151
  // was never configured.
1184
1152
  if (batteryPowerW !== undefined && this.calibrationDriver) {
@@ -1371,7 +1339,10 @@ class SunspecBattery extends BaseSunspecDevice {
1371
1339
  console.error('Battery not connected');
1372
1340
  return false;
1373
1341
  }
1374
- console.log('Writing battery controls:', controls);
1342
+ // Redundant with the modbus client's own per-write debug trace. Keep at debug
1343
+ // so the high-level info logs (setStorageMode / enableGridCharging / etc.) stay
1344
+ // the only info-level signal per battery-control action.
1345
+ console.debug('Writing battery controls:', controls);
1375
1346
  return this.sunspecClient.writeBatteryControls(this.unitId, controls);
1376
1347
  }
1377
1348
  mapToEnyoStorageMode(storageMode) {
@@ -1469,8 +1440,6 @@ class SunspecBattery extends BaseSunspecDevice {
1469
1440
  this.dataBus = this.energyApp.useDataBus();
1470
1441
  this.dataBusListenerId = this.dataBus.listenForMessages([
1471
1442
  enyo_data_bus_value_js_1.EnyoDataBusMessageEnum.SetStorageScheduleV1,
1472
- enyo_data_bus_value_js_1.EnyoDataBusMessageEnum.StartCalibrationV1,
1473
- enyo_data_bus_value_js_1.EnyoDataBusMessageEnum.StopCalibrationV1,
1474
1443
  ], (entry) => this.handleStorageCommand(entry));
1475
1444
  if (!this.applianceId) {
1476
1445
  throw new Error("SunspecBattery.startDataBusListening: applianceId required — call connect() first.");
@@ -1509,12 +1478,6 @@ class SunspecBattery extends BaseSunspecDevice {
1509
1478
  case enyo_data_bus_value_js_1.EnyoDataBusMessageEnum.SetStorageScheduleV1:
1510
1479
  this.handleSetStorageScheduleAck(entry);
1511
1480
  break;
1512
- case enyo_data_bus_value_js_1.EnyoDataBusMessageEnum.StartCalibrationV1:
1513
- await this.handleStartCalibration(entry);
1514
- break;
1515
- case enyo_data_bus_value_js_1.EnyoDataBusMessageEnum.StopCalibrationV1:
1516
- await this.handleStopCalibration(entry);
1517
- break;
1518
1481
  }
1519
1482
  }
1520
1483
  catch (error) {
@@ -1554,51 +1517,6 @@ class SunspecBattery extends BaseSunspecDevice {
1554
1517
  await this.snapshotService.initialize();
1555
1518
  console.log(`Battery ${this.applianceId}: snapshot service initialized`);
1556
1519
  }
1557
- async handleStartCalibration(msg) {
1558
- if (!this.isConnected() || !this.applianceId) {
1559
- this.sendCommandAcknowledge(msg.id, msg.message, enyo_data_bus_value_js_1.EnyoCommandAcknowledgeAnswerEnum.Rejected, 'Not connected');
1560
- return;
1561
- }
1562
- if (!this.snapshotService) {
1563
- await this.initSnapshotService();
1564
- }
1565
- if (!this.snapshotService) {
1566
- this.sendCommandAcknowledge(msg.id, msg.message, enyo_data_bus_value_js_1.EnyoCommandAcknowledgeAnswerEnum.Rejected, 'Snapshot service unavailable');
1567
- return;
1568
- }
1569
- if (this.snapshotService.isCalibrating()) {
1570
- console.log(`Battery ${this.applianceId}: calibration already active — ack idempotently`);
1571
- this.sendCommandAcknowledge(msg.id, msg.message, enyo_data_bus_value_js_1.EnyoCommandAcknowledgeAnswerEnum.Accepted);
1572
- return;
1573
- }
1574
- console.log(`Battery ${this.applianceId}: handling StartCalibrationV1`);
1575
- const controls = await this.sunspecClient.readBatteryControls(this.unitId);
1576
- if (!controls) {
1577
- this.sendCommandAcknowledge(msg.id, msg.message, enyo_data_bus_value_js_1.EnyoCommandAcknowledgeAnswerEnum.Rejected, 'Failed to read battery controls for snapshot');
1578
- return;
1579
- }
1580
- try {
1581
- await this.snapshotService.startCalibration(controls);
1582
- }
1583
- catch (error) {
1584
- this.sendCommandAcknowledge(msg.id, msg.message, enyo_data_bus_value_js_1.EnyoCommandAcknowledgeAnswerEnum.Rejected, `Failed to persist snapshot: ${error}`);
1585
- return;
1586
- }
1587
- this.sendCommandAcknowledge(msg.id, msg.message, enyo_data_bus_value_js_1.EnyoCommandAcknowledgeAnswerEnum.Accepted);
1588
- }
1589
- async handleStopCalibration(msg) {
1590
- if (!this.applianceId) {
1591
- this.sendCommandAcknowledge(msg.id, msg.message, enyo_data_bus_value_js_1.EnyoCommandAcknowledgeAnswerEnum.Rejected, 'Not initialized');
1592
- return;
1593
- }
1594
- console.log(`Battery ${this.applianceId}: handling StopCalibrationV1`);
1595
- // SnapshotService.stopCalibration fires `restoreBatterySnapshot` internally
1596
- // with reason="stop" before returning. Failures from the restore callback are
1597
- // logged inside the callback (the persisted snapshot is already gone — see
1598
- // library notes) so we always ack Accepted here.
1599
- await this.snapshotService?.stopCalibration();
1600
- this.sendCommandAcknowledge(msg.id, msg.message, enyo_data_bus_value_js_1.EnyoCommandAcknowledgeAnswerEnum.Accepted);
1601
- }
1602
1520
  /**
1603
1521
  * `onRestore` callback for the battery's {@link SnapshotService}. Writes only the
1604
1522
  * subset of writable battery fields touched during the calibration. Errors are
@@ -1704,13 +1622,11 @@ class SunspecMeter extends BaseSunspecDevice {
1704
1622
  console.error(`Failed to update meter appliance: ${error}`);
1705
1623
  }
1706
1624
  }
1707
- this.startDataBusListening();
1708
1625
  }
1709
1626
  /**
1710
1627
  * Disconnect from the meter and update appliance state
1711
1628
  */
1712
1629
  async disconnect() {
1713
- this.stopDataBusListening();
1714
1630
  if (this.applianceId) {
1715
1631
  try {
1716
1632
  await this.applianceManager.updateApplianceState(this.applianceId, enyo_appliance_js_1.EnyoApplianceConnectionType.Connector, enyo_appliance_js_1.EnyoApplianceStateEnum.Offline);
@@ -1722,35 +1638,6 @@ class SunspecMeter extends BaseSunspecDevice {
1722
1638
  // Close just this meter's unit; other devices on the same network device stay open.
1723
1639
  await this.sunspecClient.disconnectUnit(this.unitId);
1724
1640
  }
1725
- /**
1726
- * Meter does not implement calibration; it only subscribes to Start/StopCalibrationV1 to
1727
- * answer NotSupported (per the data-bus contract that every command must be acknowledged).
1728
- */
1729
- startDataBusListening() {
1730
- if (this.dataBusListenerId) {
1731
- return;
1732
- }
1733
- this.dataBus = this.energyApp.useDataBus();
1734
- this.dataBusListenerId = this.dataBus.listenForMessages([
1735
- enyo_data_bus_value_js_1.EnyoDataBusMessageEnum.StartCalibrationV1,
1736
- enyo_data_bus_value_js_1.EnyoDataBusMessageEnum.StopCalibrationV1,
1737
- ], (entry) => this.handleMeterCommand(entry));
1738
- console.log(`Meter ${this.applianceId}: started data bus listening (listener ${this.dataBusListenerId})`);
1739
- }
1740
- stopDataBusListening() {
1741
- if (this.dataBusListenerId && this.dataBus) {
1742
- this.dataBus.unsubscribe(this.dataBusListenerId);
1743
- console.log(`Meter ${this.applianceId}: stopped data bus listening (listener ${this.dataBusListenerId})`);
1744
- }
1745
- this.dataBusListenerId = undefined;
1746
- this.dataBus = undefined;
1747
- }
1748
- handleMeterCommand(entry) {
1749
- if (entry.applianceId !== this.applianceId) {
1750
- return;
1751
- }
1752
- this.sendCommandAcknowledge(entry.id, entry.message, enyo_data_bus_value_js_1.EnyoCommandAcknowledgeAnswerEnum.NotSupported, 'Meter does not support calibration');
1753
- }
1754
1641
  /**
1755
1642
  * Update meter data and return data bus messages
1756
1643
  */
@@ -178,8 +178,6 @@ export declare class SunspecInverter extends BaseSunspecDevice {
178
178
  * process restarts. Idempotent.
179
179
  */
180
180
  private initSnapshotService;
181
- private handleStartCalibration;
182
- private handleStopCalibration;
183
181
  /**
184
182
  * `onRestore` callback for the inverter's {@link SnapshotService}. Writes only the
185
183
  * subset of writable inverter fields that other commands actually touched during the
@@ -217,6 +215,24 @@ export declare function detectFeaturesFromRegisters(batteryData: SunspecBatteryD
217
215
  * the full detected set to preserve the old all-or-nothing semantics on
218
216
  * upgrade.
219
217
  */
218
+ /**
219
+ * Pick the live battery power, in preference order:
220
+ *
221
+ * 1. Model 160 (MPPT) `StCha 3` / `StDisCha 4` — direct DC-link reading,
222
+ * passed in as the already-summed `mpptBatteryPowerW`.
223
+ * 2. Model 802 `w` (offset 47) — surfaced as `chargePower` / `dischargePower`
224
+ * by the Model 802 path of `SunspecModbusClient.readBatteryData`.
225
+ * 3. `undefined` — no reliable live source on this device.
226
+ *
227
+ * The Model 124 path of `readBatteryData` no longer manufactures
228
+ * `chargePower` / `dischargePower` from `inWRte × wChaMax` (a commanded rate
229
+ * cap, not a live measurement). So whenever this function sees
230
+ * `chargePower` / `dischargePower` defined, they came from Model 802.
231
+ *
232
+ * Exported as a free function so the preference logic can be unit-tested
233
+ * without the full `SunspecBattery` scaffold.
234
+ */
235
+ export declare function selectLiveBatteryPowerW(mpptBatteryPowerW: number | undefined, batteryData: SunspecBatteryData | null): number | undefined;
220
236
  export declare function filterFeaturesByCalibrationResult(detected: EnyoBatteryFeature[], result: CalibrationResult | undefined, controllable: readonly EnyoBatteryFeature[]): EnyoBatteryFeature[];
221
237
  /**
222
238
  * Sunspec Battery implementation
@@ -408,8 +424,6 @@ export declare class SunspecBattery extends BaseSunspecDevice {
408
424
  * process restarts. Idempotent.
409
425
  */
410
426
  private initSnapshotService;
411
- private handleStartCalibration;
412
- private handleStopCalibration;
413
427
  /**
414
428
  * `onRestore` callback for the battery's {@link SnapshotService}. Writes only the
415
429
  * subset of writable battery fields touched during the calibration. Errors are
@@ -432,13 +446,6 @@ export declare class SunspecMeter extends BaseSunspecDevice {
432
446
  * Disconnect from the meter and update appliance state
433
447
  */
434
448
  disconnect(): Promise<void>;
435
- /**
436
- * Meter does not implement calibration; it only subscribes to Start/StopCalibrationV1 to
437
- * answer NotSupported (per the data-bus contract that every command must be acknowledged).
438
- */
439
- startDataBusListening(): void;
440
- stopDataBusListening(): void;
441
- private handleMeterCommand;
442
449
  /**
443
450
  * Update meter data and return data bus messages
444
451
  */
@@ -486,7 +486,10 @@ class SunspecModbusClient {
486
486
  }
487
487
  catch (error) {
488
488
  console.debug(`No SunSpec device at unit ${unitId}: ${error}`);
489
- console.log(`Discovery complete for unit ${unitId}. Found 0 models: []`);
489
+ // Discovery summary at line 594 below is the info-level outcome.
490
+ // This 0-models branch is the same outcome as a normal "no device found",
491
+ // covered already by the debug above. Keep at debug.
492
+ console.debug(`Discovery complete for unit ${unitId}. Found 0 models: []`);
490
493
  return models;
491
494
  }
492
495
  currentAddress = addressInfo.nextAddress;
@@ -495,14 +498,14 @@ class SunspecModbusClient {
495
498
  const buffer = await instance.readHoldingRegisters(currentAddress, 2);
496
499
  const modelData = [buffer.readUInt16BE(0), buffer.readUInt16BE(2)];
497
500
  if (!modelData || modelData.length < 2) {
498
- console.log(`No data at address ${currentAddress}, ending discovery`);
501
+ console.debug(`No data at address ${currentAddress}, ending discovery`);
499
502
  break;
500
503
  }
501
504
  const modelId = modelData[0];
502
505
  const modelLength = modelData[1];
503
506
  // Check for end marker
504
507
  if (modelId === 0xFFFF || modelId === 65535) {
505
- console.log(`Found end marker at address ${currentAddress}`);
508
+ console.debug(`Found end marker at address ${currentAddress}`);
506
509
  break;
507
510
  }
508
511
  // Store discovered model
@@ -512,7 +515,9 @@ class SunspecModbusClient {
512
515
  length: modelLength
513
516
  };
514
517
  models.set(modelId, model);
515
- console.log(`Discovered Model ${modelId} at address ${currentAddress} with length ${modelLength} (unit ${unitId})`);
518
+ // Per-model discovery step. The end-of-discovery summary below is the
519
+ // info-level outcome; the per-model walk is debug-only.
520
+ console.debug(`Discovered Model ${modelId} at address ${currentAddress} with length ${modelLength} (unit ${unitId})`);
516
521
  // Jump to next model: current address + 2 (header) + model length
517
522
  currentAddress = currentAddress + 2 + modelLength;
518
523
  }
@@ -701,7 +706,9 @@ class SunspecModbusClient {
701
706
  // Write to holding registers
702
707
  await instance.writeMultipleRegisters(address, registerValues);
703
708
  this.connectionHealth.recordSuccess();
704
- console.log(`Successfully wrote value ${value} to register ${address} (unit ${unitId})`);
709
+ // Per-register write success fires for every parameter inside higher-level
710
+ // writers (writeBatteryControls / writeInverterControls). Demoted to debug.
711
+ console.debug(`Successfully wrote value ${value} to register ${address} (unit ${unitId})`);
705
712
  return true;
706
713
  }
707
714
  catch (error) {
@@ -1589,17 +1596,21 @@ class SunspecModbusClient {
1589
1596
  voltage: this.applyScaleFactor(inBatVRaw, scaleFactors.InBatV_SF, 'uint16'),
1590
1597
  status: !this.isUnimplementedValue(chaStRaw, 'enum16') ? chaStRaw : undefined
1591
1598
  };
1592
- // Calculate charge/discharge power if rates are available
1593
- if (data.inWRte !== undefined && data.wChaMax !== undefined) {
1594
- data.chargePower = (data.inWRte / 100) * data.wChaMax;
1595
- console.debug(`Calculated Charge Power: (inWRte: ${data.inWRte}, wChaMax: ${data.wChaMax}) ${data.chargePower?.toFixed(2)} W`);
1596
- }
1597
- if (data.outWRte !== undefined && data.wChaMax !== undefined) {
1598
- // Assuming WDisChaMax is similar to WChaMax for simplicity
1599
- data.dischargePower = Math.abs((data.outWRte / 100) * data.wChaMax);
1600
- console.debug(`Calculated Discharge Power (inWRte: ${data.outWRte}, wChaMax: ${data.wChaMax}): ${data.dischargePower?.toFixed(2)} W`);
1601
- }
1602
- console.debug('[Model 124] Battery Data:', data);
1599
+ // chargePower / dischargePower used to be derived from
1600
+ // `(inWRte / 100) * wChaMax` and `(outWRte / 100) * wChaMax`
1601
+ // here. That formula uses Model 124's COMMANDED RATE CAPS — not
1602
+ // a live measurement and produces e.g. 5000 W of "charging"
1603
+ // for an idle battery with inWRte = 100 % and a 5 kW nameplate.
1604
+ // Live battery power must come from a real source: Model 160
1605
+ // StCha 3 / StDisCha 4 (see SunspecBattery.extractBatteryPower
1606
+ // FromMPPT) or Model 802 `w` at offset 47 (the Model 802 branch
1607
+ // of this method, just below). Model-124-only devices should
1608
+ // publish "no signal" rather than the commanded cap.
1609
+ // See plans/please-review-the-implementation-groovy-thacker.md.
1610
+ // Single-line JSON debug dump — Node's default formatter would split
1611
+ // the object across many lines; stringify keeps the whole snapshot
1612
+ // on one log entry so it stays grep-able and round-trippable.
1613
+ console.debug(`[Battery] unit=${unitId} model=124 data=${JSON.stringify(data)}`);
1603
1614
  return data;
1604
1615
  }
1605
1616
  else if (model.id === 802) {
@@ -1636,17 +1647,18 @@ class SunspecModbusClient {
1636
1647
  chargePower,
1637
1648
  dischargePower,
1638
1649
  };
1639
- console.debug('[Model 802] Battery Data:', result);
1650
+ console.debug(`[Battery] unit=${unitId} model=802 data=${JSON.stringify(result)}`);
1640
1651
  return result;
1641
1652
  }
1642
1653
  else {
1643
- // Handle other battery models (803) if needed
1644
- console.debug(`Battery Model ${model.id} reading not yet implemented`);
1645
- return {
1654
+ // Handle other battery models (803) if needed.
1655
+ const stub = {
1646
1656
  blockNumber: model.id,
1647
1657
  blockAddress: model.address,
1648
- blockLength: model.length
1658
+ blockLength: model.length,
1649
1659
  };
1660
+ console.debug(`[Battery] unit=${unitId} model=${model.id} (not yet implemented) data=${JSON.stringify(stub)}`);
1661
+ return stub;
1650
1662
  }
1651
1663
  }
1652
1664
  catch (error) {
@@ -1664,7 +1676,11 @@ class SunspecModbusClient {
1664
1676
  return false;
1665
1677
  }
1666
1678
  const baseAddr = model.address;
1667
- console.log(`Writing Battery Controls to Model 124 at base address: ${baseAddr} (unit ${unitId})`);
1679
+ // Per-register write trace is high-volume (every schedule entry transition fires
1680
+ // a writeBatteryControls). Demoted to debug; consumers that need the trail can
1681
+ // raise their log level. High-level callers (setStorageMode, enableGridCharging,
1682
+ // setFeedInLimit, etc.) still emit one info-level line per action.
1683
+ console.debug(`Writing Battery Controls to Model 124 at base address: ${baseAddr} (unit ${unitId})`);
1668
1684
  try {
1669
1685
  // Write order: source pin and parameter writes land BEFORE the
1670
1686
  // control mode so the device only "starts acting" once every
@@ -1674,7 +1690,7 @@ class SunspecModbusClient {
1674
1690
  // Write charge source setting (Register 17)
1675
1691
  if (controls.chaGriSet !== undefined) {
1676
1692
  await this.writeRegisterValue(unitId, baseAddr + 17, controls.chaGriSet, 'uint16');
1677
- console.log(`Set charge source to ${controls.chaGriSet === sunspec_interfaces_js_1.SunspecChargeSource.GRID ? 'GRID' : 'PV'}`);
1693
+ console.debug(`Set charge source to ${controls.chaGriSet === sunspec_interfaces_js_1.SunspecChargeSource.GRID ? 'GRID' : 'PV'}`);
1678
1694
  }
1679
1695
  // Write maximum charge power (Register 2) - needs scale factor
1680
1696
  if (controls.wChaMax !== undefined) {
@@ -1682,7 +1698,7 @@ class SunspecModbusClient {
1682
1698
  const scaleFactor = await this.readRegisterValue(unitId, scaleFactorAddr, 1, 'int16');
1683
1699
  const scaledValue = Math.round(controls.wChaMax / Math.pow(10, scaleFactor));
1684
1700
  await this.writeRegisterValue(unitId, baseAddr + 2, scaledValue, 'uint16');
1685
- console.log(`Set max charge power to ${controls.wChaMax}W (scaled: ${scaledValue})`);
1701
+ console.debug(`Set max charge power to ${controls.wChaMax}W (scaled: ${scaledValue})`);
1686
1702
  }
1687
1703
  // Write charge rate (Register 13) - needs scale factor
1688
1704
  if (controls.inWRte !== undefined) {
@@ -1690,7 +1706,7 @@ class SunspecModbusClient {
1690
1706
  const scaleFactor = await this.readRegisterValue(unitId, scaleFactorAddr, 1, 'int16');
1691
1707
  const scaledValue = Math.round(controls.inWRte / Math.pow(10, scaleFactor));
1692
1708
  await this.writeRegisterValue(unitId, baseAddr + 13, scaledValue, 'int16');
1693
- console.log(`Set charge rate to ${controls.inWRte}% (scaled: ${scaledValue})`);
1709
+ console.debug(`Set charge rate to ${controls.inWRte}% (scaled: ${scaledValue})`);
1694
1710
  }
1695
1711
  // Write discharge rate (Register 12) - needs scale factor
1696
1712
  if (controls.outWRte !== undefined) {
@@ -1698,7 +1714,7 @@ class SunspecModbusClient {
1698
1714
  const scaleFactor = await this.readRegisterValue(unitId, scaleFactorAddr, 1, 'int16');
1699
1715
  const scaledValue = Math.round(controls.outWRte / Math.pow(10, scaleFactor));
1700
1716
  await this.writeRegisterValue(unitId, baseAddr + 12, scaledValue, 'int16');
1701
- console.log(`Set discharge rate to ${controls.outWRte}% (scaled: ${scaledValue})`);
1717
+ console.debug(`Set discharge rate to ${controls.outWRte}% (scaled: ${scaledValue})`);
1702
1718
  }
1703
1719
  // Write minimum reserve percentage (Register 7) - needs scale factor
1704
1720
  if (controls.minRsvPct !== undefined) {
@@ -1706,16 +1722,16 @@ class SunspecModbusClient {
1706
1722
  const scaleFactor = await this.readRegisterValue(unitId, scaleFactorAddr, 1, 'int16');
1707
1723
  const scaledValue = Math.round(controls.minRsvPct / Math.pow(10, scaleFactor));
1708
1724
  await this.writeRegisterValue(unitId, baseAddr + 7, scaledValue, 'uint16');
1709
- console.log(`Set minimum reserve to ${controls.minRsvPct}% (scaled: ${scaledValue})`);
1725
+ console.debug(`Set minimum reserve to ${controls.minRsvPct}% (scaled: ${scaledValue})`);
1710
1726
  }
1711
1727
  // Storage control mode (Register 5) — written LAST so all
1712
1728
  // governing parameters are already in place when the device
1713
1729
  // transitions into the new mode.
1714
1730
  if (controls.storCtlMod !== undefined) {
1715
1731
  await this.writeRegisterValue(unitId, baseAddr + 5, controls.storCtlMod, 'uint16');
1716
- console.log(`Set storage control mode to 0x${controls.storCtlMod.toString(16)}`);
1732
+ console.debug(`Set storage control mode to 0x${controls.storCtlMod.toString(16)}`);
1717
1733
  }
1718
- console.log('Battery controls written successfully');
1734
+ console.debug('Battery controls written successfully');
1719
1735
  return true;
1720
1736
  }
1721
1737
  catch (error) {
@@ -1766,10 +1782,12 @@ class SunspecModbusClient {
1766
1782
  async readBatteryControls(unitId) {
1767
1783
  const model = this.findModel(unitId, sunspec_interfaces_js_1.SunspecModelId.Battery);
1768
1784
  if (!model) {
1769
- console.log(`Battery model 124 not found on unit ${unitId}`);
1785
+ // Fires per readBatteryControls attempt — noisy on non-battery units
1786
+ // that go through the same code path. Demoted to debug.
1787
+ console.debug(`Battery model 124 not found on unit ${unitId}`);
1770
1788
  return null;
1771
1789
  }
1772
- console.log(`Reading Battery Controls from Model 124 at base address: ${model.address} (unit ${unitId})`);
1790
+ console.debug(`Reading Battery Controls from Model 124 at base address: ${model.address} (unit ${unitId})`);
1773
1791
  try {
1774
1792
  // Read entire model block in a single Modbus call
1775
1793
  const buffer = await this.readModelBlock(unitId, model);
@@ -1984,7 +2002,7 @@ class SunspecModbusClient {
1984
2002
  console.debug(`Common block model not found on unit ${unitId}`);
1985
2003
  return null;
1986
2004
  }
1987
- console.log(`Reading Common Block - Model address: ${model.address} (unit ${unitId})`);
2005
+ console.debug(`Reading Common Block - Model address: ${model.address} (unit ${unitId})`);
1988
2006
  try {
1989
2007
  // Read entire model block in a single Modbus call
1990
2008
  const buffer = await this.readModelBlock(unitId, model);
@@ -2144,7 +2162,8 @@ class SunspecModbusClient {
2144
2162
  async readInverterControls(unitId) {
2145
2163
  const model = this.findModel(unitId, sunspec_interfaces_js_1.SunspecModelId.Controls);
2146
2164
  if (!model) {
2147
- console.log(`Controls model 123 not found on unit ${unitId}`);
2165
+ // Same trace-only rationale as the Model 124 not-found message above.
2166
+ console.debug(`Controls model 123 not found on unit ${unitId}`);
2148
2167
  return null;
2149
2168
  }
2150
2169
  try {
@@ -2253,17 +2272,17 @@ class SunspecModbusClient {
2253
2272
  const scaleFactor = sfBuffer.readInt16BE(0);
2254
2273
  const scaledValue = Math.round(settings.WMax / Math.pow(10, scaleFactor));
2255
2274
  // Writing registers needs to be implemented in EnergyAppModbusInstance
2256
- // For now, log the write operation
2257
- console.log(`Would write value ${scaledValue} to register ${baseAddr}`);
2275
+ // For now, log the (would-be) write operation. Dry-run trace only — debug.
2276
+ console.debug(`Would write value ${scaledValue} to register ${baseAddr}`);
2258
2277
  }
2259
2278
  if (settings.VRef !== undefined) {
2260
2279
  const sfBuffer = await instance.readHoldingRegisters(baseAddr + 23, 1);
2261
2280
  const scaleFactor = sfBuffer.readInt16BE(0);
2262
2281
  const scaledValue = Math.round(settings.VRef / Math.pow(10, scaleFactor));
2263
- console.log(`Would write value ${scaledValue} to register ${baseAddr + 1}`);
2282
+ console.debug(`Would write value ${scaledValue} to register ${baseAddr + 1}`);
2264
2283
  }
2265
2284
  // Add more write operations for other settings as needed
2266
- console.log('Inverter settings written successfully');
2285
+ console.debug('Inverter settings written successfully');
2267
2286
  return true;
2268
2287
  }
2269
2288
  catch (error) {
@@ -2282,36 +2301,37 @@ class SunspecModbusClient {
2282
2301
  }
2283
2302
  const baseAddr = model.address;
2284
2303
  try {
2285
- // Connection control (Register 2)
2304
+ // Per-field inverter-control writes are debug-only; the high-level callers
2305
+ // (`setFeedInLimit`, etc.) still log the action and outcome at info level.
2286
2306
  if (controls.Conn !== undefined) {
2287
2307
  await this.writeRegisterValue(unitId, baseAddr + 2, controls.Conn, 'uint16');
2288
- console.log(`Set connection control to ${controls.Conn}`);
2308
+ console.debug(`Set connection control to ${controls.Conn}`);
2289
2309
  }
2290
2310
  // Power limit control (Register 3) - needs scale factor
2291
2311
  if (controls.WMaxLimPct !== undefined) {
2292
2312
  const scaleFactor = await this.readRegisterValue(unitId, baseAddr + 21, 1, 'int16');
2293
2313
  const scaledValue = Math.round(controls.WMaxLimPct / Math.pow(10, scaleFactor));
2294
2314
  await this.writeRegisterValue(unitId, baseAddr + 3, scaledValue, 'uint16');
2295
- console.log(`Set power limit to ${controls.WMaxLimPct}% (scaled: ${scaledValue})`);
2315
+ console.debug(`Set power limit to ${controls.WMaxLimPct}% (scaled: ${scaledValue})`);
2296
2316
  }
2297
2317
  // Throttle enable/disable (Register 7)
2298
2318
  if (controls.WMaxLim_Ena !== undefined) {
2299
2319
  await this.writeRegisterValue(unitId, baseAddr + 7, controls.WMaxLim_Ena, 'uint16');
2300
- console.log(`Set throttle enable to ${controls.WMaxLim_Ena}`);
2320
+ console.debug(`Set throttle enable to ${controls.WMaxLim_Ena}`);
2301
2321
  }
2302
2322
  // Power factor control (Register 8) - needs scale factor
2303
2323
  if (controls.OutPFSet !== undefined) {
2304
2324
  const scaleFactor = await this.readRegisterValue(unitId, baseAddr + 22, 1, 'int16');
2305
2325
  const scaledValue = Math.round(controls.OutPFSet / Math.pow(10, scaleFactor));
2306
2326
  await this.writeRegisterValue(unitId, baseAddr + 8, scaledValue, 'int16');
2307
- console.log(`Set power factor to ${controls.OutPFSet} (scaled: ${scaledValue})`);
2327
+ console.debug(`Set power factor to ${controls.OutPFSet} (scaled: ${scaledValue})`);
2308
2328
  }
2309
2329
  // Power factor enable/disable (Register 12)
2310
2330
  if (controls.OutPFSet_Ena !== undefined) {
2311
2331
  await this.writeRegisterValue(unitId, baseAddr + 12, controls.OutPFSet_Ena, 'uint16');
2312
- console.log(`Set PF enable to ${controls.OutPFSet_Ena}`);
2332
+ console.debug(`Set PF enable to ${controls.OutPFSet_Ena}`);
2313
2333
  }
2314
- console.log('Inverter controls written successfully');
2334
+ console.debug('Inverter controls written successfully');
2315
2335
  return true;
2316
2336
  }
2317
2337
  catch (error) {
@@ -9,7 +9,7 @@ exports.getSdkVersion = getSdkVersion;
9
9
  /**
10
10
  * Current version of the enyo Energy App SDK.
11
11
  */
12
- exports.SDK_VERSION = '0.0.74';
12
+ exports.SDK_VERSION = '0.0.76';
13
13
  /**
14
14
  * Gets the current SDK version.
15
15
  * @returns The semantic version string of the SDK
@@ -5,7 +5,7 @@
5
5
  /**
6
6
  * Current version of the enyo Energy App SDK.
7
7
  */
8
- export declare const SDK_VERSION = "0.0.74";
8
+ export declare const SDK_VERSION = "0.0.76";
9
9
  /**
10
10
  * Gets the current SDK version.
11
11
  * @returns The semantic version string of the SDK
@@ -178,8 +178,6 @@ export declare class SunspecInverter extends BaseSunspecDevice {
178
178
  * process restarts. Idempotent.
179
179
  */
180
180
  private initSnapshotService;
181
- private handleStartCalibration;
182
- private handleStopCalibration;
183
181
  /**
184
182
  * `onRestore` callback for the inverter's {@link SnapshotService}. Writes only the
185
183
  * subset of writable inverter fields that other commands actually touched during the
@@ -217,6 +215,24 @@ export declare function detectFeaturesFromRegisters(batteryData: SunspecBatteryD
217
215
  * the full detected set to preserve the old all-or-nothing semantics on
218
216
  * upgrade.
219
217
  */
218
+ /**
219
+ * Pick the live battery power, in preference order:
220
+ *
221
+ * 1. Model 160 (MPPT) `StCha 3` / `StDisCha 4` — direct DC-link reading,
222
+ * passed in as the already-summed `mpptBatteryPowerW`.
223
+ * 2. Model 802 `w` (offset 47) — surfaced as `chargePower` / `dischargePower`
224
+ * by the Model 802 path of `SunspecModbusClient.readBatteryData`.
225
+ * 3. `undefined` — no reliable live source on this device.
226
+ *
227
+ * The Model 124 path of `readBatteryData` no longer manufactures
228
+ * `chargePower` / `dischargePower` from `inWRte × wChaMax` (a commanded rate
229
+ * cap, not a live measurement). So whenever this function sees
230
+ * `chargePower` / `dischargePower` defined, they came from Model 802.
231
+ *
232
+ * Exported as a free function so the preference logic can be unit-tested
233
+ * without the full `SunspecBattery` scaffold.
234
+ */
235
+ export declare function selectLiveBatteryPowerW(mpptBatteryPowerW: number | undefined, batteryData: SunspecBatteryData | null): number | undefined;
220
236
  export declare function filterFeaturesByCalibrationResult(detected: EnyoBatteryFeature[], result: CalibrationResult | undefined, controllable: readonly EnyoBatteryFeature[]): EnyoBatteryFeature[];
221
237
  /**
222
238
  * Sunspec Battery implementation
@@ -408,8 +424,6 @@ export declare class SunspecBattery extends BaseSunspecDevice {
408
424
  * process restarts. Idempotent.
409
425
  */
410
426
  private initSnapshotService;
411
- private handleStartCalibration;
412
- private handleStopCalibration;
413
427
  /**
414
428
  * `onRestore` callback for the battery's {@link SnapshotService}. Writes only the
415
429
  * subset of writable battery fields touched during the calibration. Errors are
@@ -432,13 +446,6 @@ export declare class SunspecMeter extends BaseSunspecDevice {
432
446
  * Disconnect from the meter and update appliance state
433
447
  */
434
448
  disconnect(): Promise<void>;
435
- /**
436
- * Meter does not implement calibration; it only subscribes to Start/StopCalibrationV1 to
437
- * answer NotSupported (per the data-bus contract that every command must be acknowledged).
438
- */
439
- startDataBusListening(): void;
440
- stopDataBusListening(): void;
441
- private handleMeterCommand;
442
449
  /**
443
450
  * Update meter data and return data bus messages
444
451
  */
@@ -705,8 +705,6 @@ export class SunspecInverter extends BaseSunspecDevice {
705
705
  this.dataBus = this.energyApp.useDataBus();
706
706
  this.dataBusListenerId = this.dataBus.listenForMessages([
707
707
  EnyoDataBusMessageEnum.SetInverterFeedInLimitV1,
708
- EnyoDataBusMessageEnum.StartCalibrationV1,
709
- EnyoDataBusMessageEnum.StopCalibrationV1,
710
708
  ], (entry) => this.handleInverterCommand(entry));
711
709
  console.log(`Inverter ${this.applianceId}: started data bus listening (listener ${this.dataBusListenerId})`);
712
710
  }
@@ -731,12 +729,6 @@ export class SunspecInverter extends BaseSunspecDevice {
731
729
  case EnyoDataBusMessageEnum.SetInverterFeedInLimitV1:
732
730
  await this.handleSetFeedInLimit(entry);
733
731
  break;
734
- case EnyoDataBusMessageEnum.StartCalibrationV1:
735
- await this.handleStartCalibration(entry);
736
- break;
737
- case EnyoDataBusMessageEnum.StopCalibrationV1:
738
- await this.handleStopCalibration(entry);
739
- break;
740
732
  }
741
733
  }
742
734
  catch (error) {
@@ -782,51 +774,6 @@ export class SunspecInverter extends BaseSunspecDevice {
782
774
  await this.snapshotService.initialize();
783
775
  console.log(`Inverter ${this.applianceId}: snapshot service initialized`);
784
776
  }
785
- async handleStartCalibration(msg) {
786
- if (!this.isConnected() || !this.applianceId) {
787
- this.sendCommandAcknowledge(msg.id, msg.message, EnyoCommandAcknowledgeAnswerEnum.Rejected, 'Not connected');
788
- return;
789
- }
790
- if (!this.snapshotService) {
791
- await this.initSnapshotService();
792
- }
793
- if (!this.snapshotService) {
794
- this.sendCommandAcknowledge(msg.id, msg.message, EnyoCommandAcknowledgeAnswerEnum.Rejected, 'Snapshot service unavailable');
795
- return;
796
- }
797
- if (this.snapshotService.isCalibrating()) {
798
- console.log(`Inverter ${this.applianceId}: calibration already active — ack idempotently`);
799
- this.sendCommandAcknowledge(msg.id, msg.message, EnyoCommandAcknowledgeAnswerEnum.Accepted);
800
- return;
801
- }
802
- console.log(`Inverter ${this.applianceId}: handling StartCalibrationV1`);
803
- const controls = await this.sunspecClient.readInverterControls(this.unitId);
804
- if (!controls) {
805
- this.sendCommandAcknowledge(msg.id, msg.message, EnyoCommandAcknowledgeAnswerEnum.Rejected, 'Failed to read inverter controls for snapshot');
806
- return;
807
- }
808
- try {
809
- await this.snapshotService.startCalibration(controls);
810
- }
811
- catch (error) {
812
- this.sendCommandAcknowledge(msg.id, msg.message, EnyoCommandAcknowledgeAnswerEnum.Rejected, `Failed to persist snapshot: ${error}`);
813
- return;
814
- }
815
- this.sendCommandAcknowledge(msg.id, msg.message, EnyoCommandAcknowledgeAnswerEnum.Accepted);
816
- }
817
- async handleStopCalibration(msg) {
818
- if (!this.applianceId) {
819
- this.sendCommandAcknowledge(msg.id, msg.message, EnyoCommandAcknowledgeAnswerEnum.Rejected, 'Not initialized');
820
- return;
821
- }
822
- console.log(`Inverter ${this.applianceId}: handling StopCalibrationV1`);
823
- // SnapshotService.stopCalibration fires `restoreInverterSnapshot` internally with
824
- // reason="stop" before returning. Any restore failure is logged by the callback
825
- // (the persisted snapshot is already gone by then — see library notes) so we
826
- // always ack Accepted from here.
827
- await this.snapshotService?.stopCalibration();
828
- this.sendCommandAcknowledge(msg.id, msg.message, EnyoCommandAcknowledgeAnswerEnum.Accepted);
829
- }
830
777
  /**
831
778
  * `onRestore` callback for the inverter's {@link SnapshotService}. Writes only the
832
779
  * subset of writable inverter fields that other commands actually touched during the
@@ -898,6 +845,35 @@ export function detectFeaturesFromRegisters(batteryData) {
898
845
  * the full detected set to preserve the old all-or-nothing semantics on
899
846
  * upgrade.
900
847
  */
848
+ /**
849
+ * Pick the live battery power, in preference order:
850
+ *
851
+ * 1. Model 160 (MPPT) `StCha 3` / `StDisCha 4` — direct DC-link reading,
852
+ * passed in as the already-summed `mpptBatteryPowerW`.
853
+ * 2. Model 802 `w` (offset 47) — surfaced as `chargePower` / `dischargePower`
854
+ * by the Model 802 path of `SunspecModbusClient.readBatteryData`.
855
+ * 3. `undefined` — no reliable live source on this device.
856
+ *
857
+ * The Model 124 path of `readBatteryData` no longer manufactures
858
+ * `chargePower` / `dischargePower` from `inWRte × wChaMax` (a commanded rate
859
+ * cap, not a live measurement). So whenever this function sees
860
+ * `chargePower` / `dischargePower` defined, they came from Model 802.
861
+ *
862
+ * Exported as a free function so the preference logic can be unit-tested
863
+ * without the full `SunspecBattery` scaffold.
864
+ */
865
+ export function selectLiveBatteryPowerW(mpptBatteryPowerW, batteryData) {
866
+ if (mpptBatteryPowerW !== undefined) {
867
+ return mpptBatteryPowerW;
868
+ }
869
+ if (!batteryData) {
870
+ return undefined;
871
+ }
872
+ if (batteryData.chargePower === undefined && batteryData.dischargePower === undefined) {
873
+ return undefined;
874
+ }
875
+ return (batteryData.chargePower ?? 0) - (batteryData.dischargePower ?? 0);
876
+ }
901
877
  export function filterFeaturesByCalibrationResult(detected, result, controllable) {
902
878
  if (!result || result.state !== 'calibrated') {
903
879
  return detected.filter(f => !controllable.includes(f));
@@ -1161,17 +1137,8 @@ export class SunspecBattery extends BaseSunspecDevice {
1161
1137
  return messages;
1162
1138
  }
1163
1139
  if (batteryData) {
1164
- const advancedBatteryModel = this.sunspecClient.findModel(this.unitId, 801);
1165
- const batteryBaseModel = this.sunspecClient.findModel(this.unitId, SunspecModelId.BatteryBase);
1166
- // Determine battery power: prefer model 802 w field, then MPPT extraction, then undefined
1167
- let batteryPowerW;
1168
- if (batteryBaseModel && (batteryData.chargePower !== undefined || batteryData.dischargePower !== undefined)) {
1169
- // Model 802 provides power directly: positive = charge, negative = discharge
1170
- batteryPowerW = (batteryData.chargePower || 0) - (batteryData.dischargePower || 0);
1171
- }
1172
- else if (!advancedBatteryModel) {
1173
- batteryPowerW = mpptBatteryPowerW;
1174
- }
1140
+ // See `selectLiveBatteryPowerW` for the source-preference rationale.
1141
+ const batteryPowerW = selectLiveBatteryPowerW(mpptBatteryPowerW, batteryData);
1175
1142
  // Feed the calibration driver's synchronous power cache. No-op when calibration
1176
1143
  // was never configured.
1177
1144
  if (batteryPowerW !== undefined && this.calibrationDriver) {
@@ -1364,7 +1331,10 @@ export class SunspecBattery extends BaseSunspecDevice {
1364
1331
  console.error('Battery not connected');
1365
1332
  return false;
1366
1333
  }
1367
- console.log('Writing battery controls:', controls);
1334
+ // Redundant with the modbus client's own per-write debug trace. Keep at debug
1335
+ // so the high-level info logs (setStorageMode / enableGridCharging / etc.) stay
1336
+ // the only info-level signal per battery-control action.
1337
+ console.debug('Writing battery controls:', controls);
1368
1338
  return this.sunspecClient.writeBatteryControls(this.unitId, controls);
1369
1339
  }
1370
1340
  mapToEnyoStorageMode(storageMode) {
@@ -1462,8 +1432,6 @@ export class SunspecBattery extends BaseSunspecDevice {
1462
1432
  this.dataBus = this.energyApp.useDataBus();
1463
1433
  this.dataBusListenerId = this.dataBus.listenForMessages([
1464
1434
  EnyoDataBusMessageEnum.SetStorageScheduleV1,
1465
- EnyoDataBusMessageEnum.StartCalibrationV1,
1466
- EnyoDataBusMessageEnum.StopCalibrationV1,
1467
1435
  ], (entry) => this.handleStorageCommand(entry));
1468
1436
  if (!this.applianceId) {
1469
1437
  throw new Error("SunspecBattery.startDataBusListening: applianceId required — call connect() first.");
@@ -1502,12 +1470,6 @@ export class SunspecBattery extends BaseSunspecDevice {
1502
1470
  case EnyoDataBusMessageEnum.SetStorageScheduleV1:
1503
1471
  this.handleSetStorageScheduleAck(entry);
1504
1472
  break;
1505
- case EnyoDataBusMessageEnum.StartCalibrationV1:
1506
- await this.handleStartCalibration(entry);
1507
- break;
1508
- case EnyoDataBusMessageEnum.StopCalibrationV1:
1509
- await this.handleStopCalibration(entry);
1510
- break;
1511
1473
  }
1512
1474
  }
1513
1475
  catch (error) {
@@ -1547,51 +1509,6 @@ export class SunspecBattery extends BaseSunspecDevice {
1547
1509
  await this.snapshotService.initialize();
1548
1510
  console.log(`Battery ${this.applianceId}: snapshot service initialized`);
1549
1511
  }
1550
- async handleStartCalibration(msg) {
1551
- if (!this.isConnected() || !this.applianceId) {
1552
- this.sendCommandAcknowledge(msg.id, msg.message, EnyoCommandAcknowledgeAnswerEnum.Rejected, 'Not connected');
1553
- return;
1554
- }
1555
- if (!this.snapshotService) {
1556
- await this.initSnapshotService();
1557
- }
1558
- if (!this.snapshotService) {
1559
- this.sendCommandAcknowledge(msg.id, msg.message, EnyoCommandAcknowledgeAnswerEnum.Rejected, 'Snapshot service unavailable');
1560
- return;
1561
- }
1562
- if (this.snapshotService.isCalibrating()) {
1563
- console.log(`Battery ${this.applianceId}: calibration already active — ack idempotently`);
1564
- this.sendCommandAcknowledge(msg.id, msg.message, EnyoCommandAcknowledgeAnswerEnum.Accepted);
1565
- return;
1566
- }
1567
- console.log(`Battery ${this.applianceId}: handling StartCalibrationV1`);
1568
- const controls = await this.sunspecClient.readBatteryControls(this.unitId);
1569
- if (!controls) {
1570
- this.sendCommandAcknowledge(msg.id, msg.message, EnyoCommandAcknowledgeAnswerEnum.Rejected, 'Failed to read battery controls for snapshot');
1571
- return;
1572
- }
1573
- try {
1574
- await this.snapshotService.startCalibration(controls);
1575
- }
1576
- catch (error) {
1577
- this.sendCommandAcknowledge(msg.id, msg.message, EnyoCommandAcknowledgeAnswerEnum.Rejected, `Failed to persist snapshot: ${error}`);
1578
- return;
1579
- }
1580
- this.sendCommandAcknowledge(msg.id, msg.message, EnyoCommandAcknowledgeAnswerEnum.Accepted);
1581
- }
1582
- async handleStopCalibration(msg) {
1583
- if (!this.applianceId) {
1584
- this.sendCommandAcknowledge(msg.id, msg.message, EnyoCommandAcknowledgeAnswerEnum.Rejected, 'Not initialized');
1585
- return;
1586
- }
1587
- console.log(`Battery ${this.applianceId}: handling StopCalibrationV1`);
1588
- // SnapshotService.stopCalibration fires `restoreBatterySnapshot` internally
1589
- // with reason="stop" before returning. Failures from the restore callback are
1590
- // logged inside the callback (the persisted snapshot is already gone — see
1591
- // library notes) so we always ack Accepted here.
1592
- await this.snapshotService?.stopCalibration();
1593
- this.sendCommandAcknowledge(msg.id, msg.message, EnyoCommandAcknowledgeAnswerEnum.Accepted);
1594
- }
1595
1512
  /**
1596
1513
  * `onRestore` callback for the battery's {@link SnapshotService}. Writes only the
1597
1514
  * subset of writable battery fields touched during the calibration. Errors are
@@ -1696,13 +1613,11 @@ export class SunspecMeter extends BaseSunspecDevice {
1696
1613
  console.error(`Failed to update meter appliance: ${error}`);
1697
1614
  }
1698
1615
  }
1699
- this.startDataBusListening();
1700
1616
  }
1701
1617
  /**
1702
1618
  * Disconnect from the meter and update appliance state
1703
1619
  */
1704
1620
  async disconnect() {
1705
- this.stopDataBusListening();
1706
1621
  if (this.applianceId) {
1707
1622
  try {
1708
1623
  await this.applianceManager.updateApplianceState(this.applianceId, EnyoApplianceConnectionType.Connector, EnyoApplianceStateEnum.Offline);
@@ -1714,35 +1629,6 @@ export class SunspecMeter extends BaseSunspecDevice {
1714
1629
  // Close just this meter's unit; other devices on the same network device stay open.
1715
1630
  await this.sunspecClient.disconnectUnit(this.unitId);
1716
1631
  }
1717
- /**
1718
- * Meter does not implement calibration; it only subscribes to Start/StopCalibrationV1 to
1719
- * answer NotSupported (per the data-bus contract that every command must be acknowledged).
1720
- */
1721
- startDataBusListening() {
1722
- if (this.dataBusListenerId) {
1723
- return;
1724
- }
1725
- this.dataBus = this.energyApp.useDataBus();
1726
- this.dataBusListenerId = this.dataBus.listenForMessages([
1727
- EnyoDataBusMessageEnum.StartCalibrationV1,
1728
- EnyoDataBusMessageEnum.StopCalibrationV1,
1729
- ], (entry) => this.handleMeterCommand(entry));
1730
- console.log(`Meter ${this.applianceId}: started data bus listening (listener ${this.dataBusListenerId})`);
1731
- }
1732
- stopDataBusListening() {
1733
- if (this.dataBusListenerId && this.dataBus) {
1734
- this.dataBus.unsubscribe(this.dataBusListenerId);
1735
- console.log(`Meter ${this.applianceId}: stopped data bus listening (listener ${this.dataBusListenerId})`);
1736
- }
1737
- this.dataBusListenerId = undefined;
1738
- this.dataBus = undefined;
1739
- }
1740
- handleMeterCommand(entry) {
1741
- if (entry.applianceId !== this.applianceId) {
1742
- return;
1743
- }
1744
- this.sendCommandAcknowledge(entry.id, entry.message, EnyoCommandAcknowledgeAnswerEnum.NotSupported, 'Meter does not support calibration');
1745
- }
1746
1632
  /**
1747
1633
  * Update meter data and return data bus messages
1748
1634
  */
@@ -481,7 +481,10 @@ export class SunspecModbusClient {
481
481
  }
482
482
  catch (error) {
483
483
  console.debug(`No SunSpec device at unit ${unitId}: ${error}`);
484
- console.log(`Discovery complete for unit ${unitId}. Found 0 models: []`);
484
+ // Discovery summary at line 594 below is the info-level outcome.
485
+ // This 0-models branch is the same outcome as a normal "no device found",
486
+ // covered already by the debug above. Keep at debug.
487
+ console.debug(`Discovery complete for unit ${unitId}. Found 0 models: []`);
485
488
  return models;
486
489
  }
487
490
  currentAddress = addressInfo.nextAddress;
@@ -490,14 +493,14 @@ export class SunspecModbusClient {
490
493
  const buffer = await instance.readHoldingRegisters(currentAddress, 2);
491
494
  const modelData = [buffer.readUInt16BE(0), buffer.readUInt16BE(2)];
492
495
  if (!modelData || modelData.length < 2) {
493
- console.log(`No data at address ${currentAddress}, ending discovery`);
496
+ console.debug(`No data at address ${currentAddress}, ending discovery`);
494
497
  break;
495
498
  }
496
499
  const modelId = modelData[0];
497
500
  const modelLength = modelData[1];
498
501
  // Check for end marker
499
502
  if (modelId === 0xFFFF || modelId === 65535) {
500
- console.log(`Found end marker at address ${currentAddress}`);
503
+ console.debug(`Found end marker at address ${currentAddress}`);
501
504
  break;
502
505
  }
503
506
  // Store discovered model
@@ -507,7 +510,9 @@ export class SunspecModbusClient {
507
510
  length: modelLength
508
511
  };
509
512
  models.set(modelId, model);
510
- console.log(`Discovered Model ${modelId} at address ${currentAddress} with length ${modelLength} (unit ${unitId})`);
513
+ // Per-model discovery step. The end-of-discovery summary below is the
514
+ // info-level outcome; the per-model walk is debug-only.
515
+ console.debug(`Discovered Model ${modelId} at address ${currentAddress} with length ${modelLength} (unit ${unitId})`);
511
516
  // Jump to next model: current address + 2 (header) + model length
512
517
  currentAddress = currentAddress + 2 + modelLength;
513
518
  }
@@ -696,7 +701,9 @@ export class SunspecModbusClient {
696
701
  // Write to holding registers
697
702
  await instance.writeMultipleRegisters(address, registerValues);
698
703
  this.connectionHealth.recordSuccess();
699
- console.log(`Successfully wrote value ${value} to register ${address} (unit ${unitId})`);
704
+ // Per-register write success fires for every parameter inside higher-level
705
+ // writers (writeBatteryControls / writeInverterControls). Demoted to debug.
706
+ console.debug(`Successfully wrote value ${value} to register ${address} (unit ${unitId})`);
700
707
  return true;
701
708
  }
702
709
  catch (error) {
@@ -1584,17 +1591,21 @@ export class SunspecModbusClient {
1584
1591
  voltage: this.applyScaleFactor(inBatVRaw, scaleFactors.InBatV_SF, 'uint16'),
1585
1592
  status: !this.isUnimplementedValue(chaStRaw, 'enum16') ? chaStRaw : undefined
1586
1593
  };
1587
- // Calculate charge/discharge power if rates are available
1588
- if (data.inWRte !== undefined && data.wChaMax !== undefined) {
1589
- data.chargePower = (data.inWRte / 100) * data.wChaMax;
1590
- console.debug(`Calculated Charge Power: (inWRte: ${data.inWRte}, wChaMax: ${data.wChaMax}) ${data.chargePower?.toFixed(2)} W`);
1591
- }
1592
- if (data.outWRte !== undefined && data.wChaMax !== undefined) {
1593
- // Assuming WDisChaMax is similar to WChaMax for simplicity
1594
- data.dischargePower = Math.abs((data.outWRte / 100) * data.wChaMax);
1595
- console.debug(`Calculated Discharge Power (inWRte: ${data.outWRte}, wChaMax: ${data.wChaMax}): ${data.dischargePower?.toFixed(2)} W`);
1596
- }
1597
- console.debug('[Model 124] Battery Data:', data);
1594
+ // chargePower / dischargePower used to be derived from
1595
+ // `(inWRte / 100) * wChaMax` and `(outWRte / 100) * wChaMax`
1596
+ // here. That formula uses Model 124's COMMANDED RATE CAPS — not
1597
+ // a live measurement and produces e.g. 5000 W of "charging"
1598
+ // for an idle battery with inWRte = 100 % and a 5 kW nameplate.
1599
+ // Live battery power must come from a real source: Model 160
1600
+ // StCha 3 / StDisCha 4 (see SunspecBattery.extractBatteryPower
1601
+ // FromMPPT) or Model 802 `w` at offset 47 (the Model 802 branch
1602
+ // of this method, just below). Model-124-only devices should
1603
+ // publish "no signal" rather than the commanded cap.
1604
+ // See plans/please-review-the-implementation-groovy-thacker.md.
1605
+ // Single-line JSON debug dump — Node's default formatter would split
1606
+ // the object across many lines; stringify keeps the whole snapshot
1607
+ // on one log entry so it stays grep-able and round-trippable.
1608
+ console.debug(`[Battery] unit=${unitId} model=124 data=${JSON.stringify(data)}`);
1598
1609
  return data;
1599
1610
  }
1600
1611
  else if (model.id === 802) {
@@ -1631,17 +1642,18 @@ export class SunspecModbusClient {
1631
1642
  chargePower,
1632
1643
  dischargePower,
1633
1644
  };
1634
- console.debug('[Model 802] Battery Data:', result);
1645
+ console.debug(`[Battery] unit=${unitId} model=802 data=${JSON.stringify(result)}`);
1635
1646
  return result;
1636
1647
  }
1637
1648
  else {
1638
- // Handle other battery models (803) if needed
1639
- console.debug(`Battery Model ${model.id} reading not yet implemented`);
1640
- return {
1649
+ // Handle other battery models (803) if needed.
1650
+ const stub = {
1641
1651
  blockNumber: model.id,
1642
1652
  blockAddress: model.address,
1643
- blockLength: model.length
1653
+ blockLength: model.length,
1644
1654
  };
1655
+ console.debug(`[Battery] unit=${unitId} model=${model.id} (not yet implemented) data=${JSON.stringify(stub)}`);
1656
+ return stub;
1645
1657
  }
1646
1658
  }
1647
1659
  catch (error) {
@@ -1659,7 +1671,11 @@ export class SunspecModbusClient {
1659
1671
  return false;
1660
1672
  }
1661
1673
  const baseAddr = model.address;
1662
- console.log(`Writing Battery Controls to Model 124 at base address: ${baseAddr} (unit ${unitId})`);
1674
+ // Per-register write trace is high-volume (every schedule entry transition fires
1675
+ // a writeBatteryControls). Demoted to debug; consumers that need the trail can
1676
+ // raise their log level. High-level callers (setStorageMode, enableGridCharging,
1677
+ // setFeedInLimit, etc.) still emit one info-level line per action.
1678
+ console.debug(`Writing Battery Controls to Model 124 at base address: ${baseAddr} (unit ${unitId})`);
1663
1679
  try {
1664
1680
  // Write order: source pin and parameter writes land BEFORE the
1665
1681
  // control mode so the device only "starts acting" once every
@@ -1669,7 +1685,7 @@ export class SunspecModbusClient {
1669
1685
  // Write charge source setting (Register 17)
1670
1686
  if (controls.chaGriSet !== undefined) {
1671
1687
  await this.writeRegisterValue(unitId, baseAddr + 17, controls.chaGriSet, 'uint16');
1672
- console.log(`Set charge source to ${controls.chaGriSet === SunspecChargeSource.GRID ? 'GRID' : 'PV'}`);
1688
+ console.debug(`Set charge source to ${controls.chaGriSet === SunspecChargeSource.GRID ? 'GRID' : 'PV'}`);
1673
1689
  }
1674
1690
  // Write maximum charge power (Register 2) - needs scale factor
1675
1691
  if (controls.wChaMax !== undefined) {
@@ -1677,7 +1693,7 @@ export class SunspecModbusClient {
1677
1693
  const scaleFactor = await this.readRegisterValue(unitId, scaleFactorAddr, 1, 'int16');
1678
1694
  const scaledValue = Math.round(controls.wChaMax / Math.pow(10, scaleFactor));
1679
1695
  await this.writeRegisterValue(unitId, baseAddr + 2, scaledValue, 'uint16');
1680
- console.log(`Set max charge power to ${controls.wChaMax}W (scaled: ${scaledValue})`);
1696
+ console.debug(`Set max charge power to ${controls.wChaMax}W (scaled: ${scaledValue})`);
1681
1697
  }
1682
1698
  // Write charge rate (Register 13) - needs scale factor
1683
1699
  if (controls.inWRte !== undefined) {
@@ -1685,7 +1701,7 @@ export class SunspecModbusClient {
1685
1701
  const scaleFactor = await this.readRegisterValue(unitId, scaleFactorAddr, 1, 'int16');
1686
1702
  const scaledValue = Math.round(controls.inWRte / Math.pow(10, scaleFactor));
1687
1703
  await this.writeRegisterValue(unitId, baseAddr + 13, scaledValue, 'int16');
1688
- console.log(`Set charge rate to ${controls.inWRte}% (scaled: ${scaledValue})`);
1704
+ console.debug(`Set charge rate to ${controls.inWRte}% (scaled: ${scaledValue})`);
1689
1705
  }
1690
1706
  // Write discharge rate (Register 12) - needs scale factor
1691
1707
  if (controls.outWRte !== undefined) {
@@ -1693,7 +1709,7 @@ export class SunspecModbusClient {
1693
1709
  const scaleFactor = await this.readRegisterValue(unitId, scaleFactorAddr, 1, 'int16');
1694
1710
  const scaledValue = Math.round(controls.outWRte / Math.pow(10, scaleFactor));
1695
1711
  await this.writeRegisterValue(unitId, baseAddr + 12, scaledValue, 'int16');
1696
- console.log(`Set discharge rate to ${controls.outWRte}% (scaled: ${scaledValue})`);
1712
+ console.debug(`Set discharge rate to ${controls.outWRte}% (scaled: ${scaledValue})`);
1697
1713
  }
1698
1714
  // Write minimum reserve percentage (Register 7) - needs scale factor
1699
1715
  if (controls.minRsvPct !== undefined) {
@@ -1701,16 +1717,16 @@ export class SunspecModbusClient {
1701
1717
  const scaleFactor = await this.readRegisterValue(unitId, scaleFactorAddr, 1, 'int16');
1702
1718
  const scaledValue = Math.round(controls.minRsvPct / Math.pow(10, scaleFactor));
1703
1719
  await this.writeRegisterValue(unitId, baseAddr + 7, scaledValue, 'uint16');
1704
- console.log(`Set minimum reserve to ${controls.minRsvPct}% (scaled: ${scaledValue})`);
1720
+ console.debug(`Set minimum reserve to ${controls.minRsvPct}% (scaled: ${scaledValue})`);
1705
1721
  }
1706
1722
  // Storage control mode (Register 5) — written LAST so all
1707
1723
  // governing parameters are already in place when the device
1708
1724
  // transitions into the new mode.
1709
1725
  if (controls.storCtlMod !== undefined) {
1710
1726
  await this.writeRegisterValue(unitId, baseAddr + 5, controls.storCtlMod, 'uint16');
1711
- console.log(`Set storage control mode to 0x${controls.storCtlMod.toString(16)}`);
1727
+ console.debug(`Set storage control mode to 0x${controls.storCtlMod.toString(16)}`);
1712
1728
  }
1713
- console.log('Battery controls written successfully');
1729
+ console.debug('Battery controls written successfully');
1714
1730
  return true;
1715
1731
  }
1716
1732
  catch (error) {
@@ -1761,10 +1777,12 @@ export class SunspecModbusClient {
1761
1777
  async readBatteryControls(unitId) {
1762
1778
  const model = this.findModel(unitId, SunspecModelId.Battery);
1763
1779
  if (!model) {
1764
- console.log(`Battery model 124 not found on unit ${unitId}`);
1780
+ // Fires per readBatteryControls attempt — noisy on non-battery units
1781
+ // that go through the same code path. Demoted to debug.
1782
+ console.debug(`Battery model 124 not found on unit ${unitId}`);
1765
1783
  return null;
1766
1784
  }
1767
- console.log(`Reading Battery Controls from Model 124 at base address: ${model.address} (unit ${unitId})`);
1785
+ console.debug(`Reading Battery Controls from Model 124 at base address: ${model.address} (unit ${unitId})`);
1768
1786
  try {
1769
1787
  // Read entire model block in a single Modbus call
1770
1788
  const buffer = await this.readModelBlock(unitId, model);
@@ -1979,7 +1997,7 @@ export class SunspecModbusClient {
1979
1997
  console.debug(`Common block model not found on unit ${unitId}`);
1980
1998
  return null;
1981
1999
  }
1982
- console.log(`Reading Common Block - Model address: ${model.address} (unit ${unitId})`);
2000
+ console.debug(`Reading Common Block - Model address: ${model.address} (unit ${unitId})`);
1983
2001
  try {
1984
2002
  // Read entire model block in a single Modbus call
1985
2003
  const buffer = await this.readModelBlock(unitId, model);
@@ -2139,7 +2157,8 @@ export class SunspecModbusClient {
2139
2157
  async readInverterControls(unitId) {
2140
2158
  const model = this.findModel(unitId, SunspecModelId.Controls);
2141
2159
  if (!model) {
2142
- console.log(`Controls model 123 not found on unit ${unitId}`);
2160
+ // Same trace-only rationale as the Model 124 not-found message above.
2161
+ console.debug(`Controls model 123 not found on unit ${unitId}`);
2143
2162
  return null;
2144
2163
  }
2145
2164
  try {
@@ -2248,17 +2267,17 @@ export class SunspecModbusClient {
2248
2267
  const scaleFactor = sfBuffer.readInt16BE(0);
2249
2268
  const scaledValue = Math.round(settings.WMax / Math.pow(10, scaleFactor));
2250
2269
  // Writing registers needs to be implemented in EnergyAppModbusInstance
2251
- // For now, log the write operation
2252
- console.log(`Would write value ${scaledValue} to register ${baseAddr}`);
2270
+ // For now, log the (would-be) write operation. Dry-run trace only — debug.
2271
+ console.debug(`Would write value ${scaledValue} to register ${baseAddr}`);
2253
2272
  }
2254
2273
  if (settings.VRef !== undefined) {
2255
2274
  const sfBuffer = await instance.readHoldingRegisters(baseAddr + 23, 1);
2256
2275
  const scaleFactor = sfBuffer.readInt16BE(0);
2257
2276
  const scaledValue = Math.round(settings.VRef / Math.pow(10, scaleFactor));
2258
- console.log(`Would write value ${scaledValue} to register ${baseAddr + 1}`);
2277
+ console.debug(`Would write value ${scaledValue} to register ${baseAddr + 1}`);
2259
2278
  }
2260
2279
  // Add more write operations for other settings as needed
2261
- console.log('Inverter settings written successfully');
2280
+ console.debug('Inverter settings written successfully');
2262
2281
  return true;
2263
2282
  }
2264
2283
  catch (error) {
@@ -2277,36 +2296,37 @@ export class SunspecModbusClient {
2277
2296
  }
2278
2297
  const baseAddr = model.address;
2279
2298
  try {
2280
- // Connection control (Register 2)
2299
+ // Per-field inverter-control writes are debug-only; the high-level callers
2300
+ // (`setFeedInLimit`, etc.) still log the action and outcome at info level.
2281
2301
  if (controls.Conn !== undefined) {
2282
2302
  await this.writeRegisterValue(unitId, baseAddr + 2, controls.Conn, 'uint16');
2283
- console.log(`Set connection control to ${controls.Conn}`);
2303
+ console.debug(`Set connection control to ${controls.Conn}`);
2284
2304
  }
2285
2305
  // Power limit control (Register 3) - needs scale factor
2286
2306
  if (controls.WMaxLimPct !== undefined) {
2287
2307
  const scaleFactor = await this.readRegisterValue(unitId, baseAddr + 21, 1, 'int16');
2288
2308
  const scaledValue = Math.round(controls.WMaxLimPct / Math.pow(10, scaleFactor));
2289
2309
  await this.writeRegisterValue(unitId, baseAddr + 3, scaledValue, 'uint16');
2290
- console.log(`Set power limit to ${controls.WMaxLimPct}% (scaled: ${scaledValue})`);
2310
+ console.debug(`Set power limit to ${controls.WMaxLimPct}% (scaled: ${scaledValue})`);
2291
2311
  }
2292
2312
  // Throttle enable/disable (Register 7)
2293
2313
  if (controls.WMaxLim_Ena !== undefined) {
2294
2314
  await this.writeRegisterValue(unitId, baseAddr + 7, controls.WMaxLim_Ena, 'uint16');
2295
- console.log(`Set throttle enable to ${controls.WMaxLim_Ena}`);
2315
+ console.debug(`Set throttle enable to ${controls.WMaxLim_Ena}`);
2296
2316
  }
2297
2317
  // Power factor control (Register 8) - needs scale factor
2298
2318
  if (controls.OutPFSet !== undefined) {
2299
2319
  const scaleFactor = await this.readRegisterValue(unitId, baseAddr + 22, 1, 'int16');
2300
2320
  const scaledValue = Math.round(controls.OutPFSet / Math.pow(10, scaleFactor));
2301
2321
  await this.writeRegisterValue(unitId, baseAddr + 8, scaledValue, 'int16');
2302
- console.log(`Set power factor to ${controls.OutPFSet} (scaled: ${scaledValue})`);
2322
+ console.debug(`Set power factor to ${controls.OutPFSet} (scaled: ${scaledValue})`);
2303
2323
  }
2304
2324
  // Power factor enable/disable (Register 12)
2305
2325
  if (controls.OutPFSet_Ena !== undefined) {
2306
2326
  await this.writeRegisterValue(unitId, baseAddr + 12, controls.OutPFSet_Ena, 'uint16');
2307
- console.log(`Set PF enable to ${controls.OutPFSet_Ena}`);
2327
+ console.debug(`Set PF enable to ${controls.OutPFSet_Ena}`);
2308
2328
  }
2309
- console.log('Inverter controls written successfully');
2329
+ console.debug('Inverter controls written successfully');
2310
2330
  return true;
2311
2331
  }
2312
2332
  catch (error) {
package/dist/version.d.ts CHANGED
@@ -5,7 +5,7 @@
5
5
  /**
6
6
  * Current version of the enyo Energy App SDK.
7
7
  */
8
- export declare const SDK_VERSION = "0.0.74";
8
+ export declare const SDK_VERSION = "0.0.76";
9
9
  /**
10
10
  * Gets the current SDK version.
11
11
  * @returns The semantic version string of the SDK
package/dist/version.js CHANGED
@@ -5,7 +5,7 @@
5
5
  /**
6
6
  * Current version of the enyo Energy App SDK.
7
7
  */
8
- export const SDK_VERSION = '0.0.74';
8
+ export const SDK_VERSION = '0.0.76';
9
9
  /**
10
10
  * Gets the current SDK version.
11
11
  * @returns The semantic version string of the SDK
package/package.json CHANGED
@@ -1,6 +1,6 @@
1
1
  {
2
2
  "name": "@enyo-energy/sunspec-sdk",
3
- "version": "0.0.74",
3
+ "version": "0.0.76",
4
4
  "description": "enyo Energy Sunspec SDK",
5
5
  "type": "module",
6
6
  "main": "dist/index.js",
@@ -41,7 +41,7 @@
41
41
  },
42
42
  "dependencies": {
43
43
  "@enyo-energy/appliance-calibration": "0.0.2",
44
- "@enyo-energy/energy-app-sdk": "0.0.143"
44
+ "@enyo-energy/energy-app-sdk": "0.0.144"
45
45
  },
46
46
  "volta": {
47
47
  "node": "22.17.0"