@enyo-energy/sunspec-sdk 0.0.105 → 1.0.1
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/README.md +90 -0
- package/dist/cjs/sunspec-devices.cjs +104 -9
- package/dist/cjs/sunspec-devices.d.cts +32 -3
- package/dist/cjs/sunspec-interfaces.d.cts +62 -0
- package/dist/cjs/sunspec-modbus-client.cjs +288 -107
- package/dist/cjs/sunspec-modbus-client.d.cts +89 -5
- package/dist/cjs/version.cjs +1 -1
- package/dist/cjs/version.d.cts +1 -1
- package/dist/sunspec-devices.d.ts +32 -3
- package/dist/sunspec-devices.js +104 -9
- package/dist/sunspec-interfaces.d.ts +62 -0
- package/dist/sunspec-modbus-client.d.ts +89 -5
- package/dist/sunspec-modbus-client.js +285 -106
- package/dist/version.d.ts +1 -1
- package/dist/version.js +1 -1
- package/package.json +2 -2
package/README.md
CHANGED
|
@@ -8,6 +8,9 @@ SunSpec Modbus client for reading data from solar inverters, batteries, meters,
|
|
|
8
8
|
- [Battery Feature Modes](#battery-feature-modes)
|
|
9
9
|
- [Battery Calibration](#battery-calibration)
|
|
10
10
|
- [Storage Schedule Control](#storage-schedule-control)
|
|
11
|
+
- [Connection Failures and Logging](#connection-failures-and-logging)
|
|
12
|
+
- [Transport Options](#transport-options)
|
|
13
|
+
- [Appliance Metadata the Registers Don't Carry](#appliance-metadata-the-registers-dont-carry)
|
|
11
14
|
- [How Addressing Works](#how-addressing-works)
|
|
12
15
|
- [Bulk Register Reading](#bulk-register-reading)
|
|
13
16
|
- [Data Types](#data-types)
|
|
@@ -352,6 +355,93 @@ The earlier `StartStorageGridChargeV1` / `StopStorageGridChargeV1` / `SetStorage
|
|
|
352
355
|
|
|
353
356
|
---
|
|
354
357
|
|
|
358
|
+
## Connection Failures and Logging
|
|
359
|
+
|
|
360
|
+
### Two kinds of failure
|
|
361
|
+
|
|
362
|
+
The client distinguishes a transaction that was **attempted and failed** from one **refused because the link is already known to be dead**. On a half-open socket (the peer stops answering while the OS still reports ESTABLISHED) the first read times out and *poisons* the unit's socket; every read that lands afterwards is refused outright, without touching the wire, until the reconnect path recycles it.
|
|
363
|
+
|
|
364
|
+
| Situation | Rejection | Log level |
|
|
365
|
+
| --- | --- | --- |
|
|
366
|
+
| Read/write attempted, timed out | `ModbusOperationTimeoutError` | one WARN on the poison transition |
|
|
367
|
+
| Read/write refused, unit already down | `SunspecUnavailableError` (`reason: 'socket-poisoned'`) | none — `debug` only |
|
|
368
|
+
| Socket recovered on reconnect | — | one INFO with `poisonedForMs` |
|
|
369
|
+
|
|
370
|
+
```ts
|
|
371
|
+
import { isSunspecUnavailableError } from '@enyo-energy/sunspec-sdk';
|
|
372
|
+
|
|
373
|
+
try {
|
|
374
|
+
await client.readRegisterValue(unitId, 40100, 1, 'uint16');
|
|
375
|
+
} catch (error) {
|
|
376
|
+
if (isSunspecUnavailableError(error)) {
|
|
377
|
+
// Already reported by the SDK — `error.reason` says why, `error.sinceMs` says
|
|
378
|
+
// how long it has been down. Log the first one of an outage at most.
|
|
379
|
+
return null;
|
|
380
|
+
}
|
|
381
|
+
console.error(`read failed`, error);
|
|
382
|
+
}
|
|
383
|
+
```
|
|
384
|
+
|
|
385
|
+
Prefer `isSunspecUnavailableError()` over `instanceof` at package boundaries, where a duplicated copy of the SDK in the module graph would break class identity.
|
|
386
|
+
|
|
387
|
+
Both error classes implement `toJSON()`, so `JSON.stringify(error)` yields a usable `{ name, message, ... }` instead of the `{}` a bare `Error` serialises to.
|
|
388
|
+
|
|
389
|
+
### One event, one line
|
|
390
|
+
|
|
391
|
+
The SDK logs **state transitions**, not states. A unit that is unreachable for an hour produces one WARN entering the poisoned state and one INFO on recovery — not one ERROR per read per poll cycle. The same rule applies to reconnect attempts: the first failure of a run is logged at ERROR, every repeat while the peer stays down at `debug`, and a success re-arms the logging for the next outage.
|
|
392
|
+
|
|
393
|
+
### Backoff
|
|
394
|
+
|
|
395
|
+
The tiered `ConnectionRetryManager` schedule is cleared by a **healthy read cycle**, not by a reconnect that merely reopened the socket. A peer that accepts TCP connections but never answers Modbus would otherwise restart the schedule at its shortest phase on every cycle and retry forever at poll rate. Because the schedule now survives such a cycle, the elapsed clock keeps growing and the intervals widen as configured (default: 10s → 30s → 1m → 5m → 15m, infinite retry). Tune with the `retryConfig` constructor argument on any device.
|
|
396
|
+
|
|
397
|
+
---
|
|
398
|
+
|
|
399
|
+
## Transport Options
|
|
400
|
+
|
|
401
|
+
Everything in `IModbusTransportConfig` is forwarded verbatim to the host's `useModbus().connect()` — the SDK owns the behaviour, this client only passes the config it was constructed with. Omitted fields stay `undefined` so the host's own defaults apply.
|
|
402
|
+
|
|
403
|
+
```ts
|
|
404
|
+
const client = getOrCreateSunspecClient(energyApp, host, 502, {
|
|
405
|
+
noParallelRequests: true, // serialize frames (slow devices, e.g. Solax)
|
|
406
|
+
waitBetweenMessagesMs: 40, // spacing between frames; only with noParallelRequests
|
|
407
|
+
pooledConnection: true, // share one socket per device (energy-app-sdk >= 1.6.0)
|
|
408
|
+
});
|
|
409
|
+
```
|
|
410
|
+
|
|
411
|
+
`pooledConnection` takes the socket from the host's shared pool — keyed by host, port, unit ID and transport settings — instead of opening one owned exclusively by this client, and its `disconnect()` releases the connection back to the pool rather than necessarily closing it. It exists for devices that accept only a handful of simultaneous Modbus clients.
|
|
412
|
+
|
|
413
|
+
Note this SDK **already** refcounts one client per `host:port` (`getOrCreateSunspecClient` / `releaseSunspecClient`), so several devices behind one gateway share a connection either way. Pooling only adds something when code *outside* this client talks to the same device — a native driver in the same app, say. Leave it unset otherwise.
|
|
414
|
+
|
|
415
|
+
The config is applied when the client for a `host:port` is **first created**; a later caller passing a different config gets the cached instance and its config is ignored.
|
|
416
|
+
|
|
417
|
+
---
|
|
418
|
+
|
|
419
|
+
## Appliance Metadata the Registers Don't Carry
|
|
420
|
+
|
|
421
|
+
Three appliance fields added in energy-app-sdk 1.6.0 have no SunSpec register behind them, so the SDK cannot derive them — it publishes what the consumer configures, and writes nothing at all when nothing is configured (spreading an explicit `undefined` would erase a value the host set through another path).
|
|
422
|
+
|
|
423
|
+
```ts
|
|
424
|
+
new SunspecInverter(energyApp, name, networkDevice, client, applianceManager,
|
|
425
|
+
1, 502, 40000, [], retryConfig, appliance, useTls, SunspecPvPowerSource.Auto,
|
|
426
|
+
{ controlAllowed: true, installedPeakPowerWp: 12_400 });
|
|
427
|
+
```
|
|
428
|
+
|
|
429
|
+
| Field | Meaning |
|
|
430
|
+
| --- | --- |
|
|
431
|
+
| `inverter.controlAllowed` | Whether the energy manager may steer this inverter (e.g. curtail). Unset = "not configured", which is not `false`. |
|
|
432
|
+
| `inverter.installedPeakPowerWp` | Module peak power from the Anlagenpass. Distinct from `maxPvProductionW`, which the SDK reads from Model 121 `WMax` (the AC side). |
|
|
433
|
+
| `battery.roundTripEfficiencyPercent` | Measured AC-to-AC round-trip efficiency (0–100). |
|
|
434
|
+
|
|
435
|
+
Round-trip efficiency is a *measured* figure that drifts with cell age and temperature, so a value fixed at construction goes stale. Push a recomputed one at any time:
|
|
436
|
+
|
|
437
|
+
```ts
|
|
438
|
+
await battery.setRoundTripEfficiencyPercent(83.2); // publishes immediately
|
|
439
|
+
```
|
|
440
|
+
|
|
441
|
+
Values outside 0–100 throw. Calling it before `connect()` is fine — the value is remembered and published with the rest of the metadata once the appliance exists. Leave it unset until enough cycles have been observed: a missing value means "not yet known", which is more useful to an optimizer than a datasheet number that overstates what the pack returns.
|
|
442
|
+
|
|
443
|
+
---
|
|
444
|
+
|
|
355
445
|
## How Addressing Works
|
|
356
446
|
|
|
357
447
|
### Base Address Detection
|
|
@@ -239,7 +239,14 @@ class BaseSunspecDevice {
|
|
|
239
239
|
`opened the socket but revalidation failed — retrying with backoff`);
|
|
240
240
|
return false;
|
|
241
241
|
}
|
|
242
|
-
|
|
242
|
+
// NOT reset() here — a reopened TCP socket is not yet a working device. On a peer
|
|
243
|
+
// that accepts connections but stops answering reads, resetting on the reconnect
|
|
244
|
+
// restarts the backoff schedule from its shortest phase on every cycle, so the
|
|
245
|
+
// schedule never advances past 10s no matter how long the outage runs: reconnect,
|
|
246
|
+
// read, time out, poison, mark offline, reconnect — indefinitely, at poll rate. The
|
|
247
|
+
// schedule is cleared instead by the first genuinely healthy read cycle (see
|
|
248
|
+
// markOfflineIfUnhealthy), which is the only evidence the link actually carries
|
|
249
|
+
// data. Until then `elapsed` keeps growing and the phases widen as intended.
|
|
243
250
|
this.consecutiveReconnectFailures = 0;
|
|
244
251
|
// Update appliance state to Connected
|
|
245
252
|
if (this.applianceId) {
|
|
@@ -255,7 +262,15 @@ class BaseSunspecDevice {
|
|
|
255
262
|
await this.onConnectionFailure(this.consecutiveReconnectFailures);
|
|
256
263
|
}
|
|
257
264
|
catch (error) {
|
|
258
|
-
|
|
265
|
+
// Transition-only: the first throw of an outage is the news; every repeat while the
|
|
266
|
+
// peer stays down is the same news again, so it drops to debug.
|
|
267
|
+
const line = `${this.constructor.name} ${this.applianceId}: Reconnect attempt #${attempt} failed: ${error}`;
|
|
268
|
+
if (this.consecutiveReconnectFailures === 0) {
|
|
269
|
+
console.error(line);
|
|
270
|
+
}
|
|
271
|
+
else {
|
|
272
|
+
console.debug(line);
|
|
273
|
+
}
|
|
259
274
|
this.consecutiveReconnectFailures += 1;
|
|
260
275
|
await this.onConnectionFailure(this.consecutiveReconnectFailures);
|
|
261
276
|
}
|
|
@@ -323,6 +338,12 @@ class BaseSunspecDevice {
|
|
|
323
338
|
*/
|
|
324
339
|
async markOfflineIfUnhealthy() {
|
|
325
340
|
if (this.sunspecClient.isHealthy(this.unitId)) {
|
|
341
|
+
// A completed read cycle on a healthy unit is the only proof the link carries data, so
|
|
342
|
+
// it — not a successful reconnect — is what clears the tiered retry schedule. See the
|
|
343
|
+
// note in tryReconnect(): resetting on reconnect alone pins a flapping device to the
|
|
344
|
+
// shortest retry phase forever.
|
|
345
|
+
this.retryManager.reset();
|
|
346
|
+
this.consecutiveReconnectFailures = 0;
|
|
326
347
|
return false;
|
|
327
348
|
}
|
|
328
349
|
console.warn(`${this.constructor.name} ${this.applianceId}: connection unhealthy after read cycle ` +
|
|
@@ -482,6 +503,7 @@ function finiteOrUndefined(value) {
|
|
|
482
503
|
class SunspecInverter extends BaseSunspecDevice {
|
|
483
504
|
capabilities;
|
|
484
505
|
pvPowerSource;
|
|
506
|
+
metadataConfig;
|
|
485
507
|
/** Emit a connection-lost faulted status after this many consecutive failed reconnect attempts. */
|
|
486
508
|
static CONNECTION_FAULT_THRESHOLD = 3;
|
|
487
509
|
/**
|
|
@@ -528,10 +550,29 @@ class SunspecInverter extends BaseSunspecDevice {
|
|
|
528
550
|
// only summed MPPT strings, or Inverter to use only the inverter total —
|
|
529
551
|
// e.g. for devices whose Model 160 strings are unreliable or whose AC
|
|
530
552
|
// includes non-PV sources (a hybrid's battery discharge).
|
|
531
|
-
pvPowerSource = sunspec_interfaces_js_1.SunspecPvPowerSource.Auto
|
|
553
|
+
pvPowerSource = sunspec_interfaces_js_1.SunspecPvPowerSource.Auto,
|
|
554
|
+
// Facts about the installation that no register carries (control policy, module peak power).
|
|
555
|
+
// Forwarded onto `appliance.inverter` on connect; see SunspecInverterMetadataConfig.
|
|
556
|
+
metadataConfig = {}) {
|
|
532
557
|
super(energyApp, name, networkDevice, sunspecClient, applianceManager, unitId, port, baseAddress, retryConfig, appliance, useTls);
|
|
533
558
|
this.capabilities = capabilities;
|
|
534
559
|
this.pvPowerSource = pvPowerSource;
|
|
560
|
+
this.metadataConfig = metadataConfig;
|
|
561
|
+
}
|
|
562
|
+
/**
|
|
563
|
+
* The consumer-supplied inverter facts, as a spreadable object that only contains the keys that
|
|
564
|
+
* were actually configured. Spreading `{ controlAllowed: undefined }` over an existing appliance
|
|
565
|
+
* would erase a value the host set elsewhere; omitting the key leaves it alone.
|
|
566
|
+
*/
|
|
567
|
+
configuredInverterMetadata() {
|
|
568
|
+
const configured = {};
|
|
569
|
+
if (this.metadataConfig.controlAllowed !== undefined) {
|
|
570
|
+
configured.controlAllowed = this.metadataConfig.controlAllowed;
|
|
571
|
+
}
|
|
572
|
+
if (this.metadataConfig.installedPeakPowerWp !== undefined) {
|
|
573
|
+
configured.installedPeakPowerWp = this.metadataConfig.installedPeakPowerWp;
|
|
574
|
+
}
|
|
575
|
+
return configured;
|
|
535
576
|
}
|
|
536
577
|
async connect() {
|
|
537
578
|
// Ensure Sunspec client is connected
|
|
@@ -565,7 +606,8 @@ class SunspecInverter extends BaseSunspecDevice {
|
|
|
565
606
|
inverter: {
|
|
566
607
|
dcStrings: this.mapDcStringToApplianceMetadata(this.mapMPPTToStrings(mpptDataList)),
|
|
567
608
|
maxPvProductionW: inverterSettings?.WMax,
|
|
568
|
-
activeProductionLimitationW: activeProductionLimitationW
|
|
609
|
+
activeProductionLimitationW: activeProductionLimitationW,
|
|
610
|
+
...this.configuredInverterMetadata()
|
|
569
611
|
}
|
|
570
612
|
});
|
|
571
613
|
console.log(`Sunspec Inverter connected: ${this.networkDevice.hostname} (${this.applianceId})`);
|
|
@@ -592,7 +634,8 @@ class SunspecInverter extends BaseSunspecDevice {
|
|
|
592
634
|
...existingAppliance?.inverter,
|
|
593
635
|
dcStrings: this.mapDcStringToApplianceMetadata(this.mapMPPTToStrings(mpptDataList)),
|
|
594
636
|
maxPvProductionW: inverterSettings?.WMax,
|
|
595
|
-
activeProductionLimitationW: activeProductionLimitationW
|
|
637
|
+
activeProductionLimitationW: activeProductionLimitationW,
|
|
638
|
+
...this.configuredInverterMetadata()
|
|
596
639
|
}
|
|
597
640
|
});
|
|
598
641
|
console.log(`Sunspec Inverter connected: ${this.networkDevice.hostname} (${this.applianceId})`);
|
|
@@ -1496,10 +1539,59 @@ class SunspecBattery extends BaseSunspecDevice {
|
|
|
1496
1539
|
enyo_battery_appliance_js_1.EnyoBatteryFeature.ChargeLimitation,
|
|
1497
1540
|
enyo_battery_appliance_js_1.EnyoBatteryFeature.DischargeLimitation,
|
|
1498
1541
|
];
|
|
1499
|
-
constructor(energyApp, name, networkDevice, sunspecClient, applianceManager, featureMode, unitId = 1, port = 502, baseAddress = 40000, capabilities = [], retryConfig, appliance, useTls
|
|
1542
|
+
constructor(energyApp, name, networkDevice, sunspecClient, applianceManager, featureMode, unitId = 1, port = 502, baseAddress = 40000, capabilities = [], retryConfig, appliance, useTls,
|
|
1543
|
+
// Battery facts no register carries (currently the measured round-trip efficiency).
|
|
1544
|
+
// Forwarded onto `appliance.battery` on connect; see SunspecBatteryMetadataConfig.
|
|
1545
|
+
metadataConfig = {}) {
|
|
1500
1546
|
super(energyApp, name, networkDevice, sunspecClient, applianceManager, unitId, port, baseAddress, retryConfig, appliance, useTls);
|
|
1501
1547
|
this.featureMode = featureMode;
|
|
1502
1548
|
this.capabilities = capabilities;
|
|
1549
|
+
this.roundTripEfficiencyPercent = metadataConfig.roundTripEfficiencyPercent;
|
|
1550
|
+
}
|
|
1551
|
+
/**
|
|
1552
|
+
* Last known round-trip efficiency, seeded from the constructor config and replaceable at
|
|
1553
|
+
* runtime via {@link setRoundTripEfficiencyPercent}. Undefined = not yet known; the SDK then
|
|
1554
|
+
* writes nothing, leaving whatever the appliance store already holds.
|
|
1555
|
+
*/
|
|
1556
|
+
roundTripEfficiencyPercent;
|
|
1557
|
+
/**
|
|
1558
|
+
* Update the battery's measured round-trip efficiency (percent, 0-100) and push it to the
|
|
1559
|
+
* appliance immediately. Meant to be called whenever the host recomputes the figure from
|
|
1560
|
+
* completed cycles - it drifts with cell age and temperature, so a value fixed at construction
|
|
1561
|
+
* goes stale. Pass `undefined` to stop asserting a value (the last published one stays in the
|
|
1562
|
+
* appliance store; the SDK does not erase it).
|
|
1563
|
+
*
|
|
1564
|
+
* Safe to call before {@link connect}: the value is remembered and published with the rest of
|
|
1565
|
+
* the metadata once the appliance exists.
|
|
1566
|
+
*/
|
|
1567
|
+
async setRoundTripEfficiencyPercent(percent) {
|
|
1568
|
+
if (percent !== undefined && (!Number.isFinite(percent) || percent < 0 || percent > 100)) {
|
|
1569
|
+
throw new Error(`setRoundTripEfficiencyPercent: ${percent} is not a percentage between 0 and 100`);
|
|
1570
|
+
}
|
|
1571
|
+
this.roundTripEfficiencyPercent = percent;
|
|
1572
|
+
if (percent === undefined || !this.applianceId)
|
|
1573
|
+
return;
|
|
1574
|
+
try {
|
|
1575
|
+
const existingAppliance = await this.applianceManager.findApplianceById(this.applianceId);
|
|
1576
|
+
await this.applianceManager.updateAppliance(this.applianceId, {
|
|
1577
|
+
battery: {
|
|
1578
|
+
...existingAppliance?.battery,
|
|
1579
|
+
roundTripEfficiencyPercent: percent
|
|
1580
|
+
}
|
|
1581
|
+
});
|
|
1582
|
+
}
|
|
1583
|
+
catch (error) {
|
|
1584
|
+
console.error(`Failed to publish round-trip efficiency for battery ${this.applianceId}: ${error}`);
|
|
1585
|
+
}
|
|
1586
|
+
}
|
|
1587
|
+
/**
|
|
1588
|
+
* The configured battery facts as a spreadable object holding only the keys actually known.
|
|
1589
|
+
* Spreading an explicit `undefined` would erase a value the host set elsewhere.
|
|
1590
|
+
*/
|
|
1591
|
+
configuredBatteryMetadata() {
|
|
1592
|
+
return this.roundTripEfficiencyPercent === undefined
|
|
1593
|
+
? {}
|
|
1594
|
+
: { roundTripEfficiencyPercent: this.roundTripEfficiencyPercent };
|
|
1503
1595
|
}
|
|
1504
1596
|
/**
|
|
1505
1597
|
* Wire the battery into `@enyo-energy/appliance-calibration`'s
|
|
@@ -1625,7 +1717,8 @@ class SunspecBattery extends BaseSunspecDevice {
|
|
|
1625
1717
|
activeChargeLimitW: activeChargeLimitW,
|
|
1626
1718
|
activeDischargeLimitW: activeDischargeLimitW,
|
|
1627
1719
|
features,
|
|
1628
|
-
gridChargingEnabled: batteryData?.chaGriSet === 1
|
|
1720
|
+
gridChargingEnabled: batteryData?.chaGriSet === 1,
|
|
1721
|
+
...this.configuredBatteryMetadata()
|
|
1629
1722
|
}
|
|
1630
1723
|
});
|
|
1631
1724
|
console.log(`Sunspec Battery connected: ${this.networkDevice.hostname} (${this.applianceId})`);
|
|
@@ -1653,7 +1746,8 @@ class SunspecBattery extends BaseSunspecDevice {
|
|
|
1653
1746
|
activeChargeLimitW: activeChargeLimitW,
|
|
1654
1747
|
activeDischargeLimitW: activeDischargeLimitW,
|
|
1655
1748
|
features,
|
|
1656
|
-
gridChargingEnabled: batteryData?.chaGriSet === 1
|
|
1749
|
+
gridChargingEnabled: batteryData?.chaGriSet === 1,
|
|
1750
|
+
...this.configuredBatteryMetadata()
|
|
1657
1751
|
}
|
|
1658
1752
|
});
|
|
1659
1753
|
console.log(`Sunspec Battery connected: ${this.networkDevice.hostname} (${this.applianceId})`);
|
|
@@ -1812,7 +1906,8 @@ class SunspecBattery extends BaseSunspecDevice {
|
|
|
1812
1906
|
activeChargeLimitW: this.computeActiveChargeLimitW(batteryData),
|
|
1813
1907
|
activeDischargeLimitW: this.computeActiveDischargeLimitW(batteryData),
|
|
1814
1908
|
features,
|
|
1815
|
-
gridChargingEnabled: batteryData?.chaGriSet === 1
|
|
1909
|
+
gridChargingEnabled: batteryData?.chaGriSet === 1,
|
|
1910
|
+
...this.configuredBatteryMetadata()
|
|
1816
1911
|
}
|
|
1817
1912
|
});
|
|
1818
1913
|
}
|
|
@@ -1,4 +1,4 @@
|
|
|
1
|
-
import { type IRetryConfig, type SunspecBatteryBaseData, SunspecBatteryCapability, type SunspecBatteryControls, type SunspecBatteryData, type SunspecBatteryFeatureMode, type SunspecInverterData, SunspecInverterCapability, SunspecPvPowerSource, SunspecPvPowerOrigin, type SunspecInverterReading, type SunspecBatteryReading, SunspecMeterCapability, type SunspecMPPTData, SunspecStorageMode, type SunspecCustomDeviceConfig } from "./sunspec-interfaces.cjs";
|
|
1
|
+
import { type IRetryConfig, type SunspecBatteryBaseData, SunspecBatteryCapability, type SunspecBatteryControls, type SunspecBatteryData, type SunspecBatteryFeatureMode, type SunspecInverterData, SunspecInverterCapability, SunspecPvPowerSource, type SunspecInverterMetadataConfig, type SunspecBatteryMetadataConfig, SunspecPvPowerOrigin, type SunspecInverterReading, type SunspecBatteryReading, SunspecMeterCapability, type SunspecMPPTData, SunspecStorageMode, type SunspecCustomDeviceConfig } from "./sunspec-interfaces.cjs";
|
|
2
2
|
import { ApplianceManager, EnergyApp } from "@enyo-energy/energy-app-sdk";
|
|
3
3
|
import { type EnyoAppliance, type EnyoApplianceErrorCode, EnyoApplianceName } from "@enyo-energy/energy-app-sdk/dist/types/enyo-appliance.js";
|
|
4
4
|
import { EnyoNetworkDevice } from "@enyo-energy/energy-app-sdk/dist/types/enyo-network-device.js";
|
|
@@ -208,6 +208,7 @@ type SunspecPvPower = {
|
|
|
208
208
|
export declare class SunspecInverter extends BaseSunspecDevice {
|
|
209
209
|
private readonly capabilities;
|
|
210
210
|
private readonly pvPowerSource;
|
|
211
|
+
private readonly metadataConfig;
|
|
211
212
|
/** Emit a connection-lost faulted status after this many consecutive failed reconnect attempts. */
|
|
212
213
|
private static readonly CONNECTION_FAULT_THRESHOLD;
|
|
213
214
|
/**
|
|
@@ -233,7 +234,13 @@ export declare class SunspecInverter extends BaseSunspecDevice {
|
|
|
233
234
|
private acEnergyDropStreak;
|
|
234
235
|
/** Consecutive corrupt reads that confirm a genuine reset/resync (vs a transient glitch). */
|
|
235
236
|
private static readonly AC_ENERGY_RESET_CONFIRM;
|
|
236
|
-
constructor(energyApp: EnergyApp, name: EnyoApplianceName[], networkDevice: EnyoNetworkDevice, sunspecClient: SunspecModbusClient, applianceManager: ApplianceManager, unitId?: number, port?: number, baseAddress?: number, capabilities?: SunspecInverterCapability[], retryConfig?: IRetryConfig, appliance?: EnyoAppliance, useTls?: boolean, pvPowerSource?: SunspecPvPowerSource);
|
|
237
|
+
constructor(energyApp: EnergyApp, name: EnyoApplianceName[], networkDevice: EnyoNetworkDevice, sunspecClient: SunspecModbusClient, applianceManager: ApplianceManager, unitId?: number, port?: number, baseAddress?: number, capabilities?: SunspecInverterCapability[], retryConfig?: IRetryConfig, appliance?: EnyoAppliance, useTls?: boolean, pvPowerSource?: SunspecPvPowerSource, metadataConfig?: SunspecInverterMetadataConfig);
|
|
238
|
+
/**
|
|
239
|
+
* The consumer-supplied inverter facts, as a spreadable object that only contains the keys that
|
|
240
|
+
* were actually configured. Spreading `{ controlAllowed: undefined }` over an existing appliance
|
|
241
|
+
* would erase a value the host set elsewhere; omitting the key leaves it alone.
|
|
242
|
+
*/
|
|
243
|
+
private configuredInverterMetadata;
|
|
237
244
|
connect(): Promise<void>;
|
|
238
245
|
disconnect(): Promise<void>;
|
|
239
246
|
readData(clockId: string, resolution: EnyoDataBusMessageResolution): Promise<EnyoDataBusMessage[]>;
|
|
@@ -547,7 +554,29 @@ export declare class SunspecBattery extends BaseSunspecDevice {
|
|
|
547
554
|
* {@link computeAdvertisedFeatures}.
|
|
548
555
|
*/
|
|
549
556
|
private static readonly CONTROLLABLE_FEATURES;
|
|
550
|
-
constructor(energyApp: EnergyApp, name: EnyoApplianceName[], networkDevice: EnyoNetworkDevice, sunspecClient: SunspecModbusClient, applianceManager: ApplianceManager, featureMode: SunspecBatteryFeatureMode, unitId?: number, port?: number, baseAddress?: number, capabilities?: SunspecBatteryCapability[], retryConfig?: IRetryConfig, appliance?: EnyoAppliance, useTls?: boolean);
|
|
557
|
+
constructor(energyApp: EnergyApp, name: EnyoApplianceName[], networkDevice: EnyoNetworkDevice, sunspecClient: SunspecModbusClient, applianceManager: ApplianceManager, featureMode: SunspecBatteryFeatureMode, unitId?: number, port?: number, baseAddress?: number, capabilities?: SunspecBatteryCapability[], retryConfig?: IRetryConfig, appliance?: EnyoAppliance, useTls?: boolean, metadataConfig?: SunspecBatteryMetadataConfig);
|
|
558
|
+
/**
|
|
559
|
+
* Last known round-trip efficiency, seeded from the constructor config and replaceable at
|
|
560
|
+
* runtime via {@link setRoundTripEfficiencyPercent}. Undefined = not yet known; the SDK then
|
|
561
|
+
* writes nothing, leaving whatever the appliance store already holds.
|
|
562
|
+
*/
|
|
563
|
+
private roundTripEfficiencyPercent?;
|
|
564
|
+
/**
|
|
565
|
+
* Update the battery's measured round-trip efficiency (percent, 0-100) and push it to the
|
|
566
|
+
* appliance immediately. Meant to be called whenever the host recomputes the figure from
|
|
567
|
+
* completed cycles - it drifts with cell age and temperature, so a value fixed at construction
|
|
568
|
+
* goes stale. Pass `undefined` to stop asserting a value (the last published one stays in the
|
|
569
|
+
* appliance store; the SDK does not erase it).
|
|
570
|
+
*
|
|
571
|
+
* Safe to call before {@link connect}: the value is remembered and published with the rest of
|
|
572
|
+
* the metadata once the appliance exists.
|
|
573
|
+
*/
|
|
574
|
+
setRoundTripEfficiencyPercent(percent: number | undefined): Promise<void>;
|
|
575
|
+
/**
|
|
576
|
+
* The configured battery facts as a spreadable object holding only the keys actually known.
|
|
577
|
+
* Spreading an explicit `undefined` would erase a value the host set elsewhere.
|
|
578
|
+
*/
|
|
579
|
+
private configuredBatteryMetadata;
|
|
551
580
|
/**
|
|
552
581
|
* Wire the battery into `@enyo-energy/appliance-calibration`'s
|
|
553
582
|
* `BatteryCalibrator` test-charge flow. Call once after {@link connect}.
|
|
@@ -46,6 +46,26 @@ export interface IModbusPacingConfig {
|
|
|
46
46
|
*/
|
|
47
47
|
waitBetweenMessagesMs?: number;
|
|
48
48
|
}
|
|
49
|
+
/**
|
|
50
|
+
* Everything the client forwards verbatim to `useModbus().connect()`: the pacing options above plus
|
|
51
|
+
* the transport options added in energy-app-sdk 1.6.0. Kept as a superset of
|
|
52
|
+
* {@link IModbusPacingConfig} so callers that already pass a pacing object keep working unchanged.
|
|
53
|
+
*/
|
|
54
|
+
export interface IModbusTransportConfig extends IModbusPacingConfig {
|
|
55
|
+
/**
|
|
56
|
+
* Take the connection from the host's shared pool of sockets — keyed by host, port, unit ID and
|
|
57
|
+
* transport settings — instead of opening one that belongs exclusively to this client (SDK
|
|
58
|
+
* `ModbusOptions.pooledConnection`, available from energy-app-sdk 1.6.0). Pooling lets several
|
|
59
|
+
* consumers of the same physical device share one TCP connection, which matters for devices that
|
|
60
|
+
* accept only a handful of simultaneous Modbus clients. A pooled `disconnect()` releases the
|
|
61
|
+
* connection back to the pool rather than necessarily closing the socket.
|
|
62
|
+
*
|
|
63
|
+
* Note that this SDK already refcounts one client per `host:port`
|
|
64
|
+
* ({@link getOrCreateSunspecClient}), so pooling only adds anything when something *outside* this
|
|
65
|
+
* client also talks to the same device. Leave it unset to keep the SDK's own default.
|
|
66
|
+
*/
|
|
67
|
+
pooledConnection?: boolean;
|
|
68
|
+
}
|
|
49
69
|
/**
|
|
50
70
|
* Resilience configuration for the Modbus client: per-operation timeouts and half-open socket
|
|
51
71
|
* detection. All fields are optional and default to sensible values, so existing consumers are
|
|
@@ -802,6 +822,29 @@ export declare enum SunspecStorageMode {
|
|
|
802
822
|
export declare enum SunspecInverterCapability {
|
|
803
823
|
FeedInLimit = "feed-in-limit"
|
|
804
824
|
}
|
|
825
|
+
/**
|
|
826
|
+
* Nameplate/policy facts about an inverter that live outside the SunSpec register map, published
|
|
827
|
+
* onto `appliance.inverter` when the device connects. Nothing here is readable from Modbus — the
|
|
828
|
+
* installation record (Anlagenpass) or the host's own configuration is the source of truth — so the
|
|
829
|
+
* SDK only forwards what the consumer supplies. Fields left `undefined` are not written, so an
|
|
830
|
+
* existing value in the appliance store survives a reconnect.
|
|
831
|
+
*
|
|
832
|
+
* Both fields were added to the appliance model in energy-app-sdk 1.6.0.
|
|
833
|
+
*/
|
|
834
|
+
export interface SunspecInverterMetadataConfig {
|
|
835
|
+
/**
|
|
836
|
+
* Whether the energy manager may actively steer this inverter (e.g. curtail production). Omit
|
|
837
|
+
* to leave the decision to the consumer's configured default — `undefined` is "not configured",
|
|
838
|
+
* which is not the same as `false`.
|
|
839
|
+
*/
|
|
840
|
+
controlAllowed?: boolean;
|
|
841
|
+
/**
|
|
842
|
+
* Peak power of the PV modules attached to this inverter, in Watt-peak. Distinct from
|
|
843
|
+
* `maxPvProductionW`, which the SDK reads from the inverter's own AC nameplate (Model 121
|
|
844
|
+
* `WMax`): the module side of the installation is not in any register.
|
|
845
|
+
*/
|
|
846
|
+
installedPeakPowerWp?: number;
|
|
847
|
+
}
|
|
805
848
|
/**
|
|
806
849
|
* Where an inverter's reported PV production (pvPowerW) is sourced from.
|
|
807
850
|
* - Auto: summed MPPT DC strings (Model 160) when present, else the inverter's
|
|
@@ -912,6 +955,25 @@ export declare enum SunspecBatteryCapability {
|
|
|
912
955
|
DischargeLimit = "discharge-limit",
|
|
913
956
|
ChargeLimit = "charge-limit"
|
|
914
957
|
}
|
|
958
|
+
/**
|
|
959
|
+
* Battery facts that live outside the SunSpec register map, published onto `appliance.battery` when
|
|
960
|
+
* the device connects. Fields left `undefined` are not written, so an existing value in the
|
|
961
|
+
* appliance store survives a reconnect.
|
|
962
|
+
*/
|
|
963
|
+
export interface SunspecBatteryMetadataConfig {
|
|
964
|
+
/**
|
|
965
|
+
* Observed AC-to-AC round-trip efficiency in percent (0–100): of the energy put into the
|
|
966
|
+
* battery, how much comes back out. Added to the appliance model in energy-app-sdk 1.6.0.
|
|
967
|
+
*
|
|
968
|
+
* A *measured* figure, not a datasheet one — it drifts with cell age, temperature and depth of
|
|
969
|
+
* discharge, and no SunSpec model reports it, so the SDK cannot derive it. Supply it from
|
|
970
|
+
* whatever the host computes over completed cycles, either here at construction or later via
|
|
971
|
+
* {@link SunspecBattery.setRoundTripEfficiencyPercent}. Leave it unset until enough cycles have
|
|
972
|
+
* been observed: a missing value means "not yet known", and is more useful to an optimizer than
|
|
973
|
+
* a nameplate number that overstates what the pack returns.
|
|
974
|
+
*/
|
|
975
|
+
roundTripEfficiencyPercent?: number;
|
|
976
|
+
}
|
|
915
977
|
/**
|
|
916
978
|
* Selects how `SunspecBattery` populates `appliance.battery.features`.
|
|
917
979
|
*
|