@enyo-energy/sunspec-sdk 0.0.103 → 0.0.104

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
@@ -7,5 +7,6 @@ export { SunspecCalibrationStorage, createSunspecCalibrationStorage } from './su
7
7
  export { SunspecBatteryCalibrationDriver } from './sunspec-battery-calibration-driver.cjs';
8
8
  export { SunspecBatteryFeatureCalibrator, type SunspecBatteryFeatureCalibratorOptions, decodeFeatureResults, } from './sunspec-battery-feature-calibrator.cjs';
9
9
  export { SunspecBatteryScheduleHandler, type SunspecScheduleRegisters, type SunspecBatteryScheduleHandlerOptions, } from './sunspec-battery-schedule-handler.cjs';
10
+ export { type EnergyAppModbus, type EnergyAppModbusInstance, type ModbusOptions, } from '@enyo-energy/energy-app-sdk/dist/packages/energy-app-modbus.js';
10
11
  export { type EnyoDataBusSetStorageScheduleV1, type EnyoStorageScheduleEntry, EnyoStorageScheduleModeEnum, EnyoStorageScheduleDirectionEnum, } from '@enyo-energy/energy-app-sdk/dist/types/enyo-data-bus-value.js';
11
12
  export { AbstractCalibrationStorage, InMemoryCalibrationStorage, type AckResult, type CalibrationResult, type CalibrationState, type CalibrationSnapshot, type CalibrationRestoreCallback, type RestoreReason, SnapshotService, type SnapshotServiceOptions, DEFAULT_AUTO_STOP_MS, AbstractBatteryCalibrationDriver, BatteryCalibrator, type BatteryCalibratorOptions, type BatteryCalibratorConfig, DEFAULT_BATTERY_CALIBRATOR_CONFIG, CalibrationResultStore, type CalibrationResultStoreData, CalibrationTrigger, type CalibrationTriggerOptions, } from '@enyo-energy/appliance-calibration';
@@ -53,15 +53,19 @@ const registryKey = (host, port) => `${host}:${port}`;
53
53
  * Get (or create) the singleton SunspecModbusClient for this network device.
54
54
  * Increments the refcount; pair with `releaseSunspecClient` on teardown.
55
55
  *
56
- * NOTE: `pacing` and `resilience` are only applied when the client is FIRST created for a given
57
- * host:port. Because the client is cached and refcounted, a later caller passing different config
58
- * receives the already-created instance and its config is ignored.
56
+ * NOTE: `pacing`, `resilience` and `modbusFactory` are only applied when the client is FIRST
57
+ * created for a given host:port. Because the client is cached and refcounted, a later caller
58
+ * passing different config receives the already-created instance and its config is ignored.
59
+ *
60
+ * `modbusFactory` lets a caller supply their own Modbus backend (the factory whose `connect()`
61
+ * opens a per-unit connection) instead of the one from `energyApp.useModbus()` — e.g. a mock for
62
+ * tests, or an alternative transport. When provided, `energyApp` may be passed as `undefined`.
59
63
  */
60
- function getOrCreateSunspecClient(energyApp, host, port = 502, pacing, resilience) {
64
+ function getOrCreateSunspecClient(energyApp, host, port = 502, pacing, resilience, modbusFactory) {
61
65
  const key = registryKey(host, port);
62
66
  let entry = CLIENT_REGISTRY.get(key);
63
67
  if (!entry) {
64
- entry = { client: new SunspecModbusClient(energyApp, pacing, resilience), refcount: 0 };
68
+ entry = { client: new SunspecModbusClient(energyApp, pacing, resilience, modbusFactory), refcount: 0 };
65
69
  CLIENT_REGISTRY.set(key, entry);
66
70
  }
67
71
  entry.refcount++;
@@ -127,6 +131,7 @@ async function retryAsync(fn, opts) {
127
131
  class SunspecModbusClient {
128
132
  energyApp;
129
133
  pacing;
134
+ modbusFactory;
130
135
  // Per-unit Modbus instance/reader/discovered-models maps. One client = one network device,
131
136
  // many unit IDs share that client (each unit ID is one EnergyAppModbusInstance underneath).
132
137
  modbusInstances = new Map();
@@ -170,20 +175,47 @@ class SunspecModbusClient {
170
175
  // the transport still reports connected but that has gone quiet past staleSocketMs is presumed
171
176
  // dead. Absent entry = no successful op yet (never treated as stale — give it a chance).
172
177
  lastOkAtByUnit = new Map();
173
- constructor(energyApp,
178
+ constructor(
179
+ // The host application. Only used to obtain the default Modbus backend via
180
+ // `energyApp.useModbus()`. May be omitted (`undefined`) when a `modbusFactory` is supplied.
181
+ energyApp,
174
182
  // Opt-in pacing (default off). Passed straight through to `useModbus().connect()`, which
175
183
  // serializes frames (`noParallelRequests`) and spaces them (`waitBetweenMessagesMs`) on the
176
184
  // connection. An empty object leaves both undefined so the SDK applies its own defaults.
177
185
  pacing = {},
178
186
  // Per-operation timeouts + half-open detection. Merged with DEFAULT_MODBUS_RESILIENCE_CONFIG
179
187
  // so omitted fields keep their defaults.
180
- resilience = {}) {
188
+ resilience = {},
189
+ // Optional custom Modbus backend. When provided, its `connect()` is used to open every
190
+ // per-unit connection instead of `energyApp.useModbus()` — letting callers plug in their own
191
+ // Modbus implementation (a mock for tests, or an alternative transport). All the resilience
192
+ // machinery (per-unit connect/reconnect, TLS, pacing, timeouts) is driven through this
193
+ // factory, which is why an already-connected instance would not do: the client re-opens
194
+ // connections on its own schedule and needs a factory to call.
195
+ modbusFactory) {
181
196
  this.energyApp = energyApp;
182
197
  this.pacing = pacing;
198
+ this.modbusFactory = modbusFactory;
199
+ if (!energyApp && !modbusFactory) {
200
+ throw new Error("SunspecModbusClient requires either an EnergyApp or a modbusFactory");
201
+ }
183
202
  this.connectionHealth = new EnergyAppModbusConnectionHealth_js_1.EnergyAppModbusConnectionHealth();
184
203
  this.modbusDataTypeConverter = new EnergyAppModbusDataTypeConverter_js_1.EnergyAppModbusDataTypeConverter();
185
204
  this.resilience = { ...sunspec_interfaces_js_1.DEFAULT_MODBUS_RESILIENCE_CONFIG, ...resilience };
186
205
  }
206
+ /**
207
+ * The Modbus backend used to open per-unit connections: the caller-supplied {@link modbusFactory}
208
+ * if one was given, otherwise the host application's default (`energyApp.useModbus()`). The
209
+ * constructor guarantees at least one of the two is present.
210
+ */
211
+ useModbus() {
212
+ if (this.modbusFactory)
213
+ return this.modbusFactory;
214
+ if (!this.energyApp) {
215
+ throw new Error("SunspecModbusClient has no Modbus backend: neither energyApp nor modbusFactory is set");
216
+ }
217
+ return this.energyApp.useModbus();
218
+ }
187
219
  /**
188
220
  * Connect to a Modbus device unit. Multiple unit IDs on the same network device share this
189
221
  * client; calling connect() with different unit IDs adds each as a separately-managed unit.
@@ -474,7 +506,7 @@ class SunspecModbusClient {
474
506
  // Enforce the connect budget ourselves in addition to forwarding it as the transport's
475
507
  // `timeout`: the transport applies it to the TCP handshake, but a sleeping/half-open peer
476
508
  // can still leave the returned promise pending — bound it independently.
477
- candidate = await this.withTimeout('connect', unitId, overallBudgetMs, () => this.energyApp.useModbus().connect({
509
+ candidate = await this.withTimeout('connect', unitId, overallBudgetMs, () => this.useModbus().connect({
478
510
  host: hosts,
479
511
  port,
480
512
  unitId,
@@ -18,7 +18,7 @@
18
18
  */
19
19
  import { type SunspecInverterControls, type SunspecInverterData, type SunspecInverterSettings, type SunspecMeterData, type SunspecModel, type SunspecMPPTData, type SunspecBatteryData, type SunspecBatteryBaseData, type SunspecBatteryControls, SunspecStorageMode, type IModbusPacingConfig, type IModbusResilienceConfig } from "./sunspec-interfaces.cjs";
20
20
  import { EnergyAppModbusDataType, IConnectionHealth } from "@enyo-energy/energy-app-sdk/dist/implementations/modbus/interfaces.js";
21
- import { EnergyAppModbusInstance } from "@enyo-energy/energy-app-sdk/dist/packages/energy-app-modbus.js";
21
+ import { EnergyAppModbus, EnergyAppModbusInstance } from "@enyo-energy/energy-app-sdk/dist/packages/energy-app-modbus.js";
22
22
  import { EnergyApp } from "@enyo-energy/energy-app-sdk";
23
23
  /**
24
24
  * Thrown when a single Modbus transaction (read/write/connect/disconnect) exceeds its configured
@@ -34,11 +34,15 @@ export declare class ModbusOperationTimeoutError extends Error {
34
34
  * Get (or create) the singleton SunspecModbusClient for this network device.
35
35
  * Increments the refcount; pair with `releaseSunspecClient` on teardown.
36
36
  *
37
- * NOTE: `pacing` and `resilience` are only applied when the client is FIRST created for a given
38
- * host:port. Because the client is cached and refcounted, a later caller passing different config
39
- * receives the already-created instance and its config is ignored.
37
+ * NOTE: `pacing`, `resilience` and `modbusFactory` are only applied when the client is FIRST
38
+ * created for a given host:port. Because the client is cached and refcounted, a later caller
39
+ * passing different config receives the already-created instance and its config is ignored.
40
+ *
41
+ * `modbusFactory` lets a caller supply their own Modbus backend (the factory whose `connect()`
42
+ * opens a per-unit connection) instead of the one from `energyApp.useModbus()` — e.g. a mock for
43
+ * tests, or an alternative transport. When provided, `energyApp` may be passed as `undefined`.
40
44
  */
41
- export declare function getOrCreateSunspecClient(energyApp: EnergyApp, host: string, port?: number, pacing?: IModbusPacingConfig, resilience?: IModbusResilienceConfig): SunspecModbusClient;
45
+ export declare function getOrCreateSunspecClient(energyApp: EnergyApp | undefined, host: string, port?: number, pacing?: IModbusPacingConfig, resilience?: IModbusResilienceConfig, modbusFactory?: EnergyAppModbus): SunspecModbusClient;
42
46
  /**
43
47
  * Release a refcount on the network-device client. When the last consumer releases,
44
48
  * the client is fully disconnected (all units closed) and removed from the registry.
@@ -63,6 +67,7 @@ export declare function retryAsync<T>(fn: (attempt: number) => Promise<T>, opts:
63
67
  export declare class SunspecModbusClient {
64
68
  private energyApp;
65
69
  private pacing;
70
+ private modbusFactory?;
66
71
  private modbusInstances;
67
72
  private faultTolerantReaders;
68
73
  private discoveredModelsByUnit;
@@ -79,7 +84,13 @@ export declare class SunspecModbusClient {
79
84
  private resilience;
80
85
  private poisonedUnits;
81
86
  private lastOkAtByUnit;
82
- constructor(energyApp: EnergyApp, pacing?: IModbusPacingConfig, resilience?: IModbusResilienceConfig);
87
+ constructor(energyApp: EnergyApp | undefined, pacing?: IModbusPacingConfig, resilience?: IModbusResilienceConfig, modbusFactory?: EnergyAppModbus | undefined);
88
+ /**
89
+ * The Modbus backend used to open per-unit connections: the caller-supplied {@link modbusFactory}
90
+ * if one was given, otherwise the host application's default (`energyApp.useModbus()`). The
91
+ * constructor guarantees at least one of the two is present.
92
+ */
93
+ private useModbus;
83
94
  /**
84
95
  * Connect to a Modbus device unit. Multiple unit IDs on the same network device share this
85
96
  * client; calling connect() with different unit IDs adds each as a separately-managed unit.
@@ -9,7 +9,7 @@ exports.getSdkVersion = getSdkVersion;
9
9
  /**
10
10
  * Current version of the enyo Energy App SDK.
11
11
  */
12
- exports.SDK_VERSION = '0.0.103';
12
+ exports.SDK_VERSION = '0.0.104';
13
13
  /**
14
14
  * Gets the current SDK version.
15
15
  * @returns The semantic version string of the SDK
@@ -5,7 +5,7 @@
5
5
  /**
6
6
  * Current version of the enyo Energy App SDK.
7
7
  */
8
- export declare const SDK_VERSION = "0.0.103";
8
+ export declare const SDK_VERSION = "0.0.104";
9
9
  /**
10
10
  * Gets the current SDK version.
11
11
  * @returns The semantic version string of the SDK
package/dist/index.d.ts CHANGED
@@ -7,5 +7,6 @@ export { SunspecCalibrationStorage, createSunspecCalibrationStorage } from './su
7
7
  export { SunspecBatteryCalibrationDriver } from './sunspec-battery-calibration-driver.js';
8
8
  export { SunspecBatteryFeatureCalibrator, type SunspecBatteryFeatureCalibratorOptions, decodeFeatureResults, } from './sunspec-battery-feature-calibrator.js';
9
9
  export { SunspecBatteryScheduleHandler, type SunspecScheduleRegisters, type SunspecBatteryScheduleHandlerOptions, } from './sunspec-battery-schedule-handler.js';
10
+ export { type EnergyAppModbus, type EnergyAppModbusInstance, type ModbusOptions, } from '@enyo-energy/energy-app-sdk/dist/packages/energy-app-modbus.js';
10
11
  export { type EnyoDataBusSetStorageScheduleV1, type EnyoStorageScheduleEntry, EnyoStorageScheduleModeEnum, EnyoStorageScheduleDirectionEnum, } from '@enyo-energy/energy-app-sdk/dist/types/enyo-data-bus-value.js';
11
12
  export { AbstractCalibrationStorage, InMemoryCalibrationStorage, type AckResult, type CalibrationResult, type CalibrationState, type CalibrationSnapshot, type CalibrationRestoreCallback, type RestoreReason, SnapshotService, type SnapshotServiceOptions, DEFAULT_AUTO_STOP_MS, AbstractBatteryCalibrationDriver, BatteryCalibrator, type BatteryCalibratorOptions, type BatteryCalibratorConfig, DEFAULT_BATTERY_CALIBRATOR_CONFIG, CalibrationResultStore, type CalibrationResultStoreData, CalibrationTrigger, type CalibrationTriggerOptions, } from '@enyo-energy/appliance-calibration';
@@ -18,7 +18,7 @@
18
18
  */
19
19
  import { type SunspecInverterControls, type SunspecInverterData, type SunspecInverterSettings, type SunspecMeterData, type SunspecModel, type SunspecMPPTData, type SunspecBatteryData, type SunspecBatteryBaseData, type SunspecBatteryControls, SunspecStorageMode, type IModbusPacingConfig, type IModbusResilienceConfig } from "./sunspec-interfaces.js";
20
20
  import { EnergyAppModbusDataType, IConnectionHealth } from "@enyo-energy/energy-app-sdk/dist/implementations/modbus/interfaces.js";
21
- import { EnergyAppModbusInstance } from "@enyo-energy/energy-app-sdk/dist/packages/energy-app-modbus.js";
21
+ import { EnergyAppModbus, EnergyAppModbusInstance } from "@enyo-energy/energy-app-sdk/dist/packages/energy-app-modbus.js";
22
22
  import { EnergyApp } from "@enyo-energy/energy-app-sdk";
23
23
  /**
24
24
  * Thrown when a single Modbus transaction (read/write/connect/disconnect) exceeds its configured
@@ -34,11 +34,15 @@ export declare class ModbusOperationTimeoutError extends Error {
34
34
  * Get (or create) the singleton SunspecModbusClient for this network device.
35
35
  * Increments the refcount; pair with `releaseSunspecClient` on teardown.
36
36
  *
37
- * NOTE: `pacing` and `resilience` are only applied when the client is FIRST created for a given
38
- * host:port. Because the client is cached and refcounted, a later caller passing different config
39
- * receives the already-created instance and its config is ignored.
37
+ * NOTE: `pacing`, `resilience` and `modbusFactory` are only applied when the client is FIRST
38
+ * created for a given host:port. Because the client is cached and refcounted, a later caller
39
+ * passing different config receives the already-created instance and its config is ignored.
40
+ *
41
+ * `modbusFactory` lets a caller supply their own Modbus backend (the factory whose `connect()`
42
+ * opens a per-unit connection) instead of the one from `energyApp.useModbus()` — e.g. a mock for
43
+ * tests, or an alternative transport. When provided, `energyApp` may be passed as `undefined`.
40
44
  */
41
- export declare function getOrCreateSunspecClient(energyApp: EnergyApp, host: string, port?: number, pacing?: IModbusPacingConfig, resilience?: IModbusResilienceConfig): SunspecModbusClient;
45
+ export declare function getOrCreateSunspecClient(energyApp: EnergyApp | undefined, host: string, port?: number, pacing?: IModbusPacingConfig, resilience?: IModbusResilienceConfig, modbusFactory?: EnergyAppModbus): SunspecModbusClient;
42
46
  /**
43
47
  * Release a refcount on the network-device client. When the last consumer releases,
44
48
  * the client is fully disconnected (all units closed) and removed from the registry.
@@ -63,6 +67,7 @@ export declare function retryAsync<T>(fn: (attempt: number) => Promise<T>, opts:
63
67
  export declare class SunspecModbusClient {
64
68
  private energyApp;
65
69
  private pacing;
70
+ private modbusFactory?;
66
71
  private modbusInstances;
67
72
  private faultTolerantReaders;
68
73
  private discoveredModelsByUnit;
@@ -79,7 +84,13 @@ export declare class SunspecModbusClient {
79
84
  private resilience;
80
85
  private poisonedUnits;
81
86
  private lastOkAtByUnit;
82
- constructor(energyApp: EnergyApp, pacing?: IModbusPacingConfig, resilience?: IModbusResilienceConfig);
87
+ constructor(energyApp: EnergyApp | undefined, pacing?: IModbusPacingConfig, resilience?: IModbusResilienceConfig, modbusFactory?: EnergyAppModbus | undefined);
88
+ /**
89
+ * The Modbus backend used to open per-unit connections: the caller-supplied {@link modbusFactory}
90
+ * if one was given, otherwise the host application's default (`energyApp.useModbus()`). The
91
+ * constructor guarantees at least one of the two is present.
92
+ */
93
+ private useModbus;
83
94
  /**
84
95
  * Connect to a Modbus device unit. Multiple unit IDs on the same network device share this
85
96
  * client; calling connect() with different unit IDs adds each as a separately-managed unit.
@@ -46,15 +46,19 @@ const registryKey = (host, port) => `${host}:${port}`;
46
46
  * Get (or create) the singleton SunspecModbusClient for this network device.
47
47
  * Increments the refcount; pair with `releaseSunspecClient` on teardown.
48
48
  *
49
- * NOTE: `pacing` and `resilience` are only applied when the client is FIRST created for a given
50
- * host:port. Because the client is cached and refcounted, a later caller passing different config
51
- * receives the already-created instance and its config is ignored.
49
+ * NOTE: `pacing`, `resilience` and `modbusFactory` are only applied when the client is FIRST
50
+ * created for a given host:port. Because the client is cached and refcounted, a later caller
51
+ * passing different config receives the already-created instance and its config is ignored.
52
+ *
53
+ * `modbusFactory` lets a caller supply their own Modbus backend (the factory whose `connect()`
54
+ * opens a per-unit connection) instead of the one from `energyApp.useModbus()` — e.g. a mock for
55
+ * tests, or an alternative transport. When provided, `energyApp` may be passed as `undefined`.
52
56
  */
53
- export function getOrCreateSunspecClient(energyApp, host, port = 502, pacing, resilience) {
57
+ export function getOrCreateSunspecClient(energyApp, host, port = 502, pacing, resilience, modbusFactory) {
54
58
  const key = registryKey(host, port);
55
59
  let entry = CLIENT_REGISTRY.get(key);
56
60
  if (!entry) {
57
- entry = { client: new SunspecModbusClient(energyApp, pacing, resilience), refcount: 0 };
61
+ entry = { client: new SunspecModbusClient(energyApp, pacing, resilience, modbusFactory), refcount: 0 };
58
62
  CLIENT_REGISTRY.set(key, entry);
59
63
  }
60
64
  entry.refcount++;
@@ -120,6 +124,7 @@ export async function retryAsync(fn, opts) {
120
124
  export class SunspecModbusClient {
121
125
  energyApp;
122
126
  pacing;
127
+ modbusFactory;
123
128
  // Per-unit Modbus instance/reader/discovered-models maps. One client = one network device,
124
129
  // many unit IDs share that client (each unit ID is one EnergyAppModbusInstance underneath).
125
130
  modbusInstances = new Map();
@@ -163,20 +168,47 @@ export class SunspecModbusClient {
163
168
  // the transport still reports connected but that has gone quiet past staleSocketMs is presumed
164
169
  // dead. Absent entry = no successful op yet (never treated as stale — give it a chance).
165
170
  lastOkAtByUnit = new Map();
166
- constructor(energyApp,
171
+ constructor(
172
+ // The host application. Only used to obtain the default Modbus backend via
173
+ // `energyApp.useModbus()`. May be omitted (`undefined`) when a `modbusFactory` is supplied.
174
+ energyApp,
167
175
  // Opt-in pacing (default off). Passed straight through to `useModbus().connect()`, which
168
176
  // serializes frames (`noParallelRequests`) and spaces them (`waitBetweenMessagesMs`) on the
169
177
  // connection. An empty object leaves both undefined so the SDK applies its own defaults.
170
178
  pacing = {},
171
179
  // Per-operation timeouts + half-open detection. Merged with DEFAULT_MODBUS_RESILIENCE_CONFIG
172
180
  // so omitted fields keep their defaults.
173
- resilience = {}) {
181
+ resilience = {},
182
+ // Optional custom Modbus backend. When provided, its `connect()` is used to open every
183
+ // per-unit connection instead of `energyApp.useModbus()` — letting callers plug in their own
184
+ // Modbus implementation (a mock for tests, or an alternative transport). All the resilience
185
+ // machinery (per-unit connect/reconnect, TLS, pacing, timeouts) is driven through this
186
+ // factory, which is why an already-connected instance would not do: the client re-opens
187
+ // connections on its own schedule and needs a factory to call.
188
+ modbusFactory) {
174
189
  this.energyApp = energyApp;
175
190
  this.pacing = pacing;
191
+ this.modbusFactory = modbusFactory;
192
+ if (!energyApp && !modbusFactory) {
193
+ throw new Error("SunspecModbusClient requires either an EnergyApp or a modbusFactory");
194
+ }
176
195
  this.connectionHealth = new EnergyAppModbusConnectionHealth();
177
196
  this.modbusDataTypeConverter = new EnergyAppModbusDataTypeConverter();
178
197
  this.resilience = { ...DEFAULT_MODBUS_RESILIENCE_CONFIG, ...resilience };
179
198
  }
199
+ /**
200
+ * The Modbus backend used to open per-unit connections: the caller-supplied {@link modbusFactory}
201
+ * if one was given, otherwise the host application's default (`energyApp.useModbus()`). The
202
+ * constructor guarantees at least one of the two is present.
203
+ */
204
+ useModbus() {
205
+ if (this.modbusFactory)
206
+ return this.modbusFactory;
207
+ if (!this.energyApp) {
208
+ throw new Error("SunspecModbusClient has no Modbus backend: neither energyApp nor modbusFactory is set");
209
+ }
210
+ return this.energyApp.useModbus();
211
+ }
180
212
  /**
181
213
  * Connect to a Modbus device unit. Multiple unit IDs on the same network device share this
182
214
  * client; calling connect() with different unit IDs adds each as a separately-managed unit.
@@ -467,7 +499,7 @@ export class SunspecModbusClient {
467
499
  // Enforce the connect budget ourselves in addition to forwarding it as the transport's
468
500
  // `timeout`: the transport applies it to the TCP handshake, but a sleeping/half-open peer
469
501
  // can still leave the returned promise pending — bound it independently.
470
- candidate = await this.withTimeout('connect', unitId, overallBudgetMs, () => this.energyApp.useModbus().connect({
502
+ candidate = await this.withTimeout('connect', unitId, overallBudgetMs, () => this.useModbus().connect({
471
503
  host: hosts,
472
504
  port,
473
505
  unitId,
package/dist/version.d.ts CHANGED
@@ -5,7 +5,7 @@
5
5
  /**
6
6
  * Current version of the enyo Energy App SDK.
7
7
  */
8
- export declare const SDK_VERSION = "0.0.103";
8
+ export declare const SDK_VERSION = "0.0.104";
9
9
  /**
10
10
  * Gets the current SDK version.
11
11
  * @returns The semantic version string of the SDK
package/dist/version.js CHANGED
@@ -5,7 +5,7 @@
5
5
  /**
6
6
  * Current version of the enyo Energy App SDK.
7
7
  */
8
- export const SDK_VERSION = '0.0.103';
8
+ export const SDK_VERSION = '0.0.104';
9
9
  /**
10
10
  * Gets the current SDK version.
11
11
  * @returns The semantic version string of the SDK
package/package.json CHANGED
@@ -1,6 +1,6 @@
1
1
  {
2
2
  "name": "@enyo-energy/sunspec-sdk",
3
- "version": "0.0.103",
3
+ "version": "0.0.104",
4
4
  "description": "enyo Energy Sunspec SDK",
5
5
  "type": "module",
6
6
  "main": "dist/index.js",
@@ -41,7 +41,7 @@
41
41
  },
42
42
  "dependencies": {
43
43
  "@enyo-energy/appliance-calibration": "0.0.3",
44
- "@enyo-energy/energy-app-sdk": "^0.0.180"
44
+ "@enyo-energy/energy-app-sdk": "^0.0.188"
45
45
  },
46
46
  "volta": {
47
47
  "node": "22.17.0"