@enyo-energy/sunspec-sdk 0.0.102 → 0.0.103

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
@@ -117,6 +117,19 @@ class BaseSunspecDevice {
117
117
  * would otherwise stay Offline forever despite reading data fine.
118
118
  */
119
119
  appliedOffline = false;
120
+ /**
121
+ * True once {@link reassertConnectedIfRecovered} has confirmed (via the
122
+ * appliance store) that this device is Connected, so it can stop probing
123
+ * for an *externally* applied Offline state. Distinct from
124
+ * {@link appliedOffline}, which only tracks Offline states this SDK object
125
+ * applied itself. An appliance can be marked Offline by a path outside the
126
+ * SDK object — e.g. the energy-app registering a boot-time offline
127
+ * placeholder before this device came up on a shared socket — which never
128
+ * sets appliedOffline; without reconciling against actual state, such a
129
+ * device stays Offline forever despite reading data fine. Reset in
130
+ * {@link markOffline} so a later Offline episode is re-checked.
131
+ */
132
+ reconciledExternalOffline = false;
120
133
  /**
121
134
  * Prefix used when persisting calibration snapshots via the library's
122
135
  * {@link SnapshotService}. Kept identical to the key the SDK used before
@@ -337,6 +350,7 @@ class BaseSunspecDevice {
337
350
  try {
338
351
  await this.applianceManager.updateApplianceState(this.applianceId, enyo_appliance_js_1.EnyoApplianceConnectionType.Connector, enyo_appliance_js_1.EnyoApplianceStateEnum.Offline);
339
352
  this.appliedOffline = true;
353
+ this.reconciledExternalOffline = false;
340
354
  }
341
355
  catch (error) {
342
356
  console.error(`${this.constructor.name} ${this.applianceId}: Failed to mark appliance offline: ${error}`);
@@ -352,17 +366,45 @@ class BaseSunspecDevice {
352
366
  * readData() and skip tryReconnect() entirely, so without this they would
353
367
  * stay Offline forever despite reading data fine.
354
368
  *
369
+ * Heals two ways an appliance can be stuck Offline while reads succeed:
370
+ * 1. This SDK object marked itself offline ({@link appliedOffline}) and a
371
+ * sibling won the reconnect race — the original shared-socket case.
372
+ * 2. The appliance was marked Offline by a path *outside* this object —
373
+ * e.g. the energy-app registering a boot-time offline placeholder
374
+ * before this device came up on the shared socket — which never sets
375
+ * appliedOffline. We reconcile against the actual stored state so the
376
+ * invariant "healthy reads ⇒ Connected" holds regardless of who
377
+ * applied the Offline.
378
+ *
355
379
  * Call this on the success path of readData() (after the
356
- * markOfflineIfUnhealthy() guard has confirmed the unit is healthy). It is
357
- * a cheap no-op unless this device was previously marked offline.
380
+ * markOfflineIfUnhealthy() guard has confirmed the unit is healthy). Cheap:
381
+ * a no-op via the appliedOffline fast path, and the external-state lookup
382
+ * runs at most once per Offline episode (latched by
383
+ * {@link reconciledExternalOffline} once Connected is confirmed).
358
384
  */
359
385
  async reassertConnectedIfRecovered() {
360
- if (!this.appliedOffline || !this.applianceId) {
386
+ if (!this.applianceId) {
361
387
  return;
362
388
  }
363
389
  if (!this.sunspecClient.isHealthy(this.unitId)) {
364
390
  return;
365
391
  }
392
+ let shouldReassert = this.appliedOffline;
393
+ // Not offline by our own hand: it may still be Offline from an
394
+ // externally applied state. Probe the store once until we confirm
395
+ // Connected, then latch so the steady state adds no extra lookups.
396
+ if (!shouldReassert && !this.reconciledExternalOffline) {
397
+ const appliance = await this.applianceManager.findApplianceById(this.applianceId);
398
+ if (appliance?.metadata?.state === enyo_appliance_js_1.EnyoApplianceStateEnum.Offline) {
399
+ shouldReassert = true;
400
+ }
401
+ else {
402
+ this.reconciledExternalOffline = true;
403
+ }
404
+ }
405
+ if (!shouldReassert) {
406
+ return;
407
+ }
366
408
  console.log(`${this.constructor.name} ${this.applianceId}: connection recovered via shared socket — re-asserting Connected`);
367
409
  try {
368
410
  await this.applianceManager.updateApplianceState(this.applianceId, enyo_appliance_js_1.EnyoApplianceConnectionType.Connector, enyo_appliance_js_1.EnyoApplianceStateEnum.Connected);
@@ -372,6 +414,7 @@ class BaseSunspecDevice {
372
414
  return;
373
415
  }
374
416
  this.appliedOffline = false;
417
+ this.reconciledExternalOffline = true;
375
418
  this.retryManager.reset();
376
419
  this.consecutiveReconnectFailures = 0;
377
420
  await this.onConnectionRestored();
@@ -37,6 +37,19 @@ export declare abstract class BaseSunspecDevice {
37
37
  * would otherwise stay Offline forever despite reading data fine.
38
38
  */
39
39
  private appliedOffline;
40
+ /**
41
+ * True once {@link reassertConnectedIfRecovered} has confirmed (via the
42
+ * appliance store) that this device is Connected, so it can stop probing
43
+ * for an *externally* applied Offline state. Distinct from
44
+ * {@link appliedOffline}, which only tracks Offline states this SDK object
45
+ * applied itself. An appliance can be marked Offline by a path outside the
46
+ * SDK object — e.g. the energy-app registering a boot-time offline
47
+ * placeholder before this device came up on a shared socket — which never
48
+ * sets appliedOffline; without reconciling against actual state, such a
49
+ * device stays Offline forever despite reading data fine. Reset in
50
+ * {@link markOffline} so a later Offline episode is re-checked.
51
+ */
52
+ private reconciledExternalOffline;
40
53
  /**
41
54
  * Prefix used when persisting calibration snapshots via the library's
42
55
  * {@link SnapshotService}. Kept identical to the key the SDK used before
@@ -152,9 +165,21 @@ export declare abstract class BaseSunspecDevice {
152
165
  * readData() and skip tryReconnect() entirely, so without this they would
153
166
  * stay Offline forever despite reading data fine.
154
167
  *
168
+ * Heals two ways an appliance can be stuck Offline while reads succeed:
169
+ * 1. This SDK object marked itself offline ({@link appliedOffline}) and a
170
+ * sibling won the reconnect race — the original shared-socket case.
171
+ * 2. The appliance was marked Offline by a path *outside* this object —
172
+ * e.g. the energy-app registering a boot-time offline placeholder
173
+ * before this device came up on the shared socket — which never sets
174
+ * appliedOffline. We reconcile against the actual stored state so the
175
+ * invariant "healthy reads ⇒ Connected" holds regardless of who
176
+ * applied the Offline.
177
+ *
155
178
  * Call this on the success path of readData() (after the
156
- * markOfflineIfUnhealthy() guard has confirmed the unit is healthy). It is
157
- * a cheap no-op unless this device was previously marked offline.
179
+ * markOfflineIfUnhealthy() guard has confirmed the unit is healthy). Cheap:
180
+ * a no-op via the appliedOffline fast path, and the external-state lookup
181
+ * runs at most once per Offline episode (latched by
182
+ * {@link reconciledExternalOffline} once Connected is confirmed).
158
183
  */
159
184
  protected reassertConnectedIfRecovered(): Promise<void>;
160
185
  protected sendCommandAcknowledge(messageId: string, acknowledgeMessage: EnyoDataBusMessageEnum | string, answer: EnyoCommandAcknowledgeAnswerEnum, rejectionReason?: string): void;
@@ -231,6 +231,10 @@ class SunspecModbusClient {
231
231
  await this._openUnit(host, port, unitId, {
232
232
  connectRetries: 0,
233
233
  connectTimeoutMs: opts.timeoutMs ?? this.resilience.connectTimeoutMs,
234
+ // Fast-fail scan: a mostly-dead RS485 range must cost ~one timeout per unit, so do
235
+ // NOT let the transport also walk a fallback host (which would double the per-unit
236
+ // cost). Warm connects/reconnects still get the in-band fallback.
237
+ useFallbackHosts: false,
234
238
  });
235
239
  console.log(`Probed Sunspec unit ${unitId} at ${host}:${port} — open (opens=${this.openCount}, closes=${this.closeCount}, openUnits=${this.modbusInstances.size})`);
236
240
  });
@@ -402,6 +406,25 @@ class SunspecModbusClient {
402
406
  return false;
403
407
  }
404
408
  }
409
+ /**
410
+ * Build the ordered host list handed to the transport's `host` option for a single connect.
411
+ * The attempt's primary target leads, followed by every OTHER known host (the other of
412
+ * primaryHost/secondaryHost) as an in-band fallback the transport walks in order — so a stale
413
+ * DNS name or a DHCP-changed IP on the first host is tolerated within one connect() instead of
414
+ * only via the client's sequential primary→secondary retry. Deduped; returns a bare string when
415
+ * no distinct fallback exists, leaving single-host devices (and their tests) unaffected.
416
+ */
417
+ buildConnectHosts(primaryTarget) {
418
+ const hosts = [primaryTarget];
419
+ const params = this.connectionParams;
420
+ if (params) {
421
+ for (const h of [params.primaryHost, params.secondaryHost]) {
422
+ if (h && !hosts.includes(h))
423
+ hosts.push(h);
424
+ }
425
+ }
426
+ return hosts.length === 1 ? hosts[0] : hosts;
427
+ }
405
428
  /**
406
429
  * Open a unit, retrying the connect on a transient failure per the resilience config
407
430
  * ({@link IModbusResilienceConfig.connectRetries}). Each attempt is a full {@link _openUnitOnce}
@@ -415,7 +438,11 @@ class SunspecModbusClient {
415
438
  async _openUnit(host, port, unitId, override) {
416
439
  const connectTimeoutMs = override?.connectTimeoutMs ?? this.resilience.connectTimeoutMs;
417
440
  const attempts = (override?.connectRetries ?? this.resilience.connectRetries) + 1;
418
- await retryAsync(() => this._openUnitOnce(host, port, unitId, connectTimeoutMs), {
441
+ // Default ON: a normal connect/reconnect hands the transport BOTH known hosts so a single
442
+ // attempt tolerates DNS/DHCP drift on the first one. probeUnit opts out to stay a fast-fail
443
+ // single-host scan (see probeUnit / _openUnitOnce).
444
+ const useFallbackHosts = override?.useFallbackHosts ?? true;
445
+ await retryAsync(() => this._openUnitOnce(host, port, unitId, connectTimeoutMs, useFallbackHosts), {
419
446
  attempts,
420
447
  delayMs: this.resilience.connectRetryDelayMs,
421
448
  onRetry: (error, attempt) => console.warn(`SunspecModbusClient: connect to ${host}:${port} unit ${unitId} failed ` +
@@ -427,15 +454,28 @@ class SunspecModbusClient {
427
454
  * Open a new Modbus instance for one unit ID and wire up its fault-tolerant reader. Bounds the
428
455
  * connect at `connectTimeoutMs`. On any failure, the just-opened instance (if any) is closed so
429
456
  * we never leak. Caller must hold the connection lock and ensure the unit is not already open.
430
- */
431
- async _openUnitOnce(host, port, unitId, connectTimeoutMs = this.resilience.connectTimeoutMs) {
457
+ *
458
+ * When `useFallbackHosts` is true (the connect/reconnect default), the transport is handed the
459
+ * full host list from {@link buildConnectHosts} — the attempt's primary target plus the other
460
+ * known host — so one connect() tolerates DNS/DHCP drift on the first host in-band, rather than
461
+ * waiting for the client's own sequential primary→secondary retry. The transport walks the list
462
+ * in order, each host bounded by `timeout` (connectTimeoutMs); we scale our own outer budget by
463
+ * the host count so a legitimate multi-host walk isn't aborted mid-fallback. probeUnit passes
464
+ * false to keep speculative RS485 scans a fast-fail single-host probe.
465
+ */
466
+ async _openUnitOnce(host, port, unitId, connectTimeoutMs = this.resilience.connectTimeoutMs, useFallbackHosts = true) {
432
467
  let candidate = null;
468
+ const hosts = useFallbackHosts ? this.buildConnectHosts(host) : host;
469
+ const hostCount = Array.isArray(hosts) ? hosts.length : 1;
470
+ // Each host in the list gets its own `timeout`; bound the whole walk at count × budget so we
471
+ // don't kill a genuine fallback to the second host with the single-host budget.
472
+ const overallBudgetMs = connectTimeoutMs * hostCount;
433
473
  try {
434
474
  // Enforce the connect budget ourselves in addition to forwarding it as the transport's
435
475
  // `timeout`: the transport applies it to the TCP handshake, but a sleeping/half-open peer
436
476
  // can still leave the returned promise pending — bound it independently.
437
- candidate = await this.withTimeout('connect', unitId, connectTimeoutMs, () => this.energyApp.useModbus().connect({
438
- host,
477
+ candidate = await this.withTimeout('connect', unitId, overallBudgetMs, () => this.energyApp.useModbus().connect({
478
+ host: hosts,
439
479
  port,
440
480
  unitId,
441
481
  timeout: connectTimeoutMs,
@@ -152,6 +152,15 @@ export declare class SunspecModbusClient {
152
152
  * if every unit succeeded.
153
153
  */
154
154
  private attemptConnection;
155
+ /**
156
+ * Build the ordered host list handed to the transport's `host` option for a single connect.
157
+ * The attempt's primary target leads, followed by every OTHER known host (the other of
158
+ * primaryHost/secondaryHost) as an in-band fallback the transport walks in order — so a stale
159
+ * DNS name or a DHCP-changed IP on the first host is tolerated within one connect() instead of
160
+ * only via the client's sequential primary→secondary retry. Deduped; returns a bare string when
161
+ * no distinct fallback exists, leaving single-host devices (and their tests) unaffected.
162
+ */
163
+ private buildConnectHosts;
155
164
  /**
156
165
  * Open a unit, retrying the connect on a transient failure per the resilience config
157
166
  * ({@link IModbusResilienceConfig.connectRetries}). Each attempt is a full {@link _openUnitOnce}
@@ -167,6 +176,14 @@ export declare class SunspecModbusClient {
167
176
  * Open a new Modbus instance for one unit ID and wire up its fault-tolerant reader. Bounds the
168
177
  * connect at `connectTimeoutMs`. On any failure, the just-opened instance (if any) is closed so
169
178
  * we never leak. Caller must hold the connection lock and ensure the unit is not already open.
179
+ *
180
+ * When `useFallbackHosts` is true (the connect/reconnect default), the transport is handed the
181
+ * full host list from {@link buildConnectHosts} — the attempt's primary target plus the other
182
+ * known host — so one connect() tolerates DNS/DHCP drift on the first host in-band, rather than
183
+ * waiting for the client's own sequential primary→secondary retry. The transport walks the list
184
+ * in order, each host bounded by `timeout` (connectTimeoutMs); we scale our own outer budget by
185
+ * the host count so a legitimate multi-host walk isn't aborted mid-fallback. probeUnit passes
186
+ * false to keep speculative RS485 scans a fast-fail single-host probe.
170
187
  */
171
188
  private _openUnitOnce;
172
189
  /**
@@ -9,7 +9,7 @@ exports.getSdkVersion = getSdkVersion;
9
9
  /**
10
10
  * Current version of the enyo Energy App SDK.
11
11
  */
12
- exports.SDK_VERSION = '0.0.102';
12
+ exports.SDK_VERSION = '0.0.103';
13
13
  /**
14
14
  * Gets the current SDK version.
15
15
  * @returns The semantic version string of the SDK
@@ -5,7 +5,7 @@
5
5
  /**
6
6
  * Current version of the enyo Energy App SDK.
7
7
  */
8
- export declare const SDK_VERSION = "0.0.102";
8
+ export declare const SDK_VERSION = "0.0.103";
9
9
  /**
10
10
  * Gets the current SDK version.
11
11
  * @returns The semantic version string of the SDK
@@ -37,6 +37,19 @@ export declare abstract class BaseSunspecDevice {
37
37
  * would otherwise stay Offline forever despite reading data fine.
38
38
  */
39
39
  private appliedOffline;
40
+ /**
41
+ * True once {@link reassertConnectedIfRecovered} has confirmed (via the
42
+ * appliance store) that this device is Connected, so it can stop probing
43
+ * for an *externally* applied Offline state. Distinct from
44
+ * {@link appliedOffline}, which only tracks Offline states this SDK object
45
+ * applied itself. An appliance can be marked Offline by a path outside the
46
+ * SDK object — e.g. the energy-app registering a boot-time offline
47
+ * placeholder before this device came up on a shared socket — which never
48
+ * sets appliedOffline; without reconciling against actual state, such a
49
+ * device stays Offline forever despite reading data fine. Reset in
50
+ * {@link markOffline} so a later Offline episode is re-checked.
51
+ */
52
+ private reconciledExternalOffline;
40
53
  /**
41
54
  * Prefix used when persisting calibration snapshots via the library's
42
55
  * {@link SnapshotService}. Kept identical to the key the SDK used before
@@ -152,9 +165,21 @@ export declare abstract class BaseSunspecDevice {
152
165
  * readData() and skip tryReconnect() entirely, so without this they would
153
166
  * stay Offline forever despite reading data fine.
154
167
  *
168
+ * Heals two ways an appliance can be stuck Offline while reads succeed:
169
+ * 1. This SDK object marked itself offline ({@link appliedOffline}) and a
170
+ * sibling won the reconnect race — the original shared-socket case.
171
+ * 2. The appliance was marked Offline by a path *outside* this object —
172
+ * e.g. the energy-app registering a boot-time offline placeholder
173
+ * before this device came up on the shared socket — which never sets
174
+ * appliedOffline. We reconcile against the actual stored state so the
175
+ * invariant "healthy reads ⇒ Connected" holds regardless of who
176
+ * applied the Offline.
177
+ *
155
178
  * Call this on the success path of readData() (after the
156
- * markOfflineIfUnhealthy() guard has confirmed the unit is healthy). It is
157
- * a cheap no-op unless this device was previously marked offline.
179
+ * markOfflineIfUnhealthy() guard has confirmed the unit is healthy). Cheap:
180
+ * a no-op via the appliedOffline fast path, and the external-state lookup
181
+ * runs at most once per Offline episode (latched by
182
+ * {@link reconciledExternalOffline} once Connected is confirmed).
158
183
  */
159
184
  protected reassertConnectedIfRecovered(): Promise<void>;
160
185
  protected sendCommandAcknowledge(messageId: string, acknowledgeMessage: EnyoDataBusMessageEnum | string, answer: EnyoCommandAcknowledgeAnswerEnum, rejectionReason?: string): void;
@@ -110,6 +110,19 @@ export class BaseSunspecDevice {
110
110
  * would otherwise stay Offline forever despite reading data fine.
111
111
  */
112
112
  appliedOffline = false;
113
+ /**
114
+ * True once {@link reassertConnectedIfRecovered} has confirmed (via the
115
+ * appliance store) that this device is Connected, so it can stop probing
116
+ * for an *externally* applied Offline state. Distinct from
117
+ * {@link appliedOffline}, which only tracks Offline states this SDK object
118
+ * applied itself. An appliance can be marked Offline by a path outside the
119
+ * SDK object — e.g. the energy-app registering a boot-time offline
120
+ * placeholder before this device came up on a shared socket — which never
121
+ * sets appliedOffline; without reconciling against actual state, such a
122
+ * device stays Offline forever despite reading data fine. Reset in
123
+ * {@link markOffline} so a later Offline episode is re-checked.
124
+ */
125
+ reconciledExternalOffline = false;
113
126
  /**
114
127
  * Prefix used when persisting calibration snapshots via the library's
115
128
  * {@link SnapshotService}. Kept identical to the key the SDK used before
@@ -330,6 +343,7 @@ export class BaseSunspecDevice {
330
343
  try {
331
344
  await this.applianceManager.updateApplianceState(this.applianceId, EnyoApplianceConnectionType.Connector, EnyoApplianceStateEnum.Offline);
332
345
  this.appliedOffline = true;
346
+ this.reconciledExternalOffline = false;
333
347
  }
334
348
  catch (error) {
335
349
  console.error(`${this.constructor.name} ${this.applianceId}: Failed to mark appliance offline: ${error}`);
@@ -345,17 +359,45 @@ export class BaseSunspecDevice {
345
359
  * readData() and skip tryReconnect() entirely, so without this they would
346
360
  * stay Offline forever despite reading data fine.
347
361
  *
362
+ * Heals two ways an appliance can be stuck Offline while reads succeed:
363
+ * 1. This SDK object marked itself offline ({@link appliedOffline}) and a
364
+ * sibling won the reconnect race — the original shared-socket case.
365
+ * 2. The appliance was marked Offline by a path *outside* this object —
366
+ * e.g. the energy-app registering a boot-time offline placeholder
367
+ * before this device came up on the shared socket — which never sets
368
+ * appliedOffline. We reconcile against the actual stored state so the
369
+ * invariant "healthy reads ⇒ Connected" holds regardless of who
370
+ * applied the Offline.
371
+ *
348
372
  * Call this on the success path of readData() (after the
349
- * markOfflineIfUnhealthy() guard has confirmed the unit is healthy). It is
350
- * a cheap no-op unless this device was previously marked offline.
373
+ * markOfflineIfUnhealthy() guard has confirmed the unit is healthy). Cheap:
374
+ * a no-op via the appliedOffline fast path, and the external-state lookup
375
+ * runs at most once per Offline episode (latched by
376
+ * {@link reconciledExternalOffline} once Connected is confirmed).
351
377
  */
352
378
  async reassertConnectedIfRecovered() {
353
- if (!this.appliedOffline || !this.applianceId) {
379
+ if (!this.applianceId) {
354
380
  return;
355
381
  }
356
382
  if (!this.sunspecClient.isHealthy(this.unitId)) {
357
383
  return;
358
384
  }
385
+ let shouldReassert = this.appliedOffline;
386
+ // Not offline by our own hand: it may still be Offline from an
387
+ // externally applied state. Probe the store once until we confirm
388
+ // Connected, then latch so the steady state adds no extra lookups.
389
+ if (!shouldReassert && !this.reconciledExternalOffline) {
390
+ const appliance = await this.applianceManager.findApplianceById(this.applianceId);
391
+ if (appliance?.metadata?.state === EnyoApplianceStateEnum.Offline) {
392
+ shouldReassert = true;
393
+ }
394
+ else {
395
+ this.reconciledExternalOffline = true;
396
+ }
397
+ }
398
+ if (!shouldReassert) {
399
+ return;
400
+ }
359
401
  console.log(`${this.constructor.name} ${this.applianceId}: connection recovered via shared socket — re-asserting Connected`);
360
402
  try {
361
403
  await this.applianceManager.updateApplianceState(this.applianceId, EnyoApplianceConnectionType.Connector, EnyoApplianceStateEnum.Connected);
@@ -365,6 +407,7 @@ export class BaseSunspecDevice {
365
407
  return;
366
408
  }
367
409
  this.appliedOffline = false;
410
+ this.reconciledExternalOffline = true;
368
411
  this.retryManager.reset();
369
412
  this.consecutiveReconnectFailures = 0;
370
413
  await this.onConnectionRestored();
@@ -152,6 +152,15 @@ export declare class SunspecModbusClient {
152
152
  * if every unit succeeded.
153
153
  */
154
154
  private attemptConnection;
155
+ /**
156
+ * Build the ordered host list handed to the transport's `host` option for a single connect.
157
+ * The attempt's primary target leads, followed by every OTHER known host (the other of
158
+ * primaryHost/secondaryHost) as an in-band fallback the transport walks in order — so a stale
159
+ * DNS name or a DHCP-changed IP on the first host is tolerated within one connect() instead of
160
+ * only via the client's sequential primary→secondary retry. Deduped; returns a bare string when
161
+ * no distinct fallback exists, leaving single-host devices (and their tests) unaffected.
162
+ */
163
+ private buildConnectHosts;
155
164
  /**
156
165
  * Open a unit, retrying the connect on a transient failure per the resilience config
157
166
  * ({@link IModbusResilienceConfig.connectRetries}). Each attempt is a full {@link _openUnitOnce}
@@ -167,6 +176,14 @@ export declare class SunspecModbusClient {
167
176
  * Open a new Modbus instance for one unit ID and wire up its fault-tolerant reader. Bounds the
168
177
  * connect at `connectTimeoutMs`. On any failure, the just-opened instance (if any) is closed so
169
178
  * we never leak. Caller must hold the connection lock and ensure the unit is not already open.
179
+ *
180
+ * When `useFallbackHosts` is true (the connect/reconnect default), the transport is handed the
181
+ * full host list from {@link buildConnectHosts} — the attempt's primary target plus the other
182
+ * known host — so one connect() tolerates DNS/DHCP drift on the first host in-band, rather than
183
+ * waiting for the client's own sequential primary→secondary retry. The transport walks the list
184
+ * in order, each host bounded by `timeout` (connectTimeoutMs); we scale our own outer budget by
185
+ * the host count so a legitimate multi-host walk isn't aborted mid-fallback. probeUnit passes
186
+ * false to keep speculative RS485 scans a fast-fail single-host probe.
170
187
  */
171
188
  private _openUnitOnce;
172
189
  /**
@@ -224,6 +224,10 @@ export class SunspecModbusClient {
224
224
  await this._openUnit(host, port, unitId, {
225
225
  connectRetries: 0,
226
226
  connectTimeoutMs: opts.timeoutMs ?? this.resilience.connectTimeoutMs,
227
+ // Fast-fail scan: a mostly-dead RS485 range must cost ~one timeout per unit, so do
228
+ // NOT let the transport also walk a fallback host (which would double the per-unit
229
+ // cost). Warm connects/reconnects still get the in-band fallback.
230
+ useFallbackHosts: false,
227
231
  });
228
232
  console.log(`Probed Sunspec unit ${unitId} at ${host}:${port} — open (opens=${this.openCount}, closes=${this.closeCount}, openUnits=${this.modbusInstances.size})`);
229
233
  });
@@ -395,6 +399,25 @@ export class SunspecModbusClient {
395
399
  return false;
396
400
  }
397
401
  }
402
+ /**
403
+ * Build the ordered host list handed to the transport's `host` option for a single connect.
404
+ * The attempt's primary target leads, followed by every OTHER known host (the other of
405
+ * primaryHost/secondaryHost) as an in-band fallback the transport walks in order — so a stale
406
+ * DNS name or a DHCP-changed IP on the first host is tolerated within one connect() instead of
407
+ * only via the client's sequential primary→secondary retry. Deduped; returns a bare string when
408
+ * no distinct fallback exists, leaving single-host devices (and their tests) unaffected.
409
+ */
410
+ buildConnectHosts(primaryTarget) {
411
+ const hosts = [primaryTarget];
412
+ const params = this.connectionParams;
413
+ if (params) {
414
+ for (const h of [params.primaryHost, params.secondaryHost]) {
415
+ if (h && !hosts.includes(h))
416
+ hosts.push(h);
417
+ }
418
+ }
419
+ return hosts.length === 1 ? hosts[0] : hosts;
420
+ }
398
421
  /**
399
422
  * Open a unit, retrying the connect on a transient failure per the resilience config
400
423
  * ({@link IModbusResilienceConfig.connectRetries}). Each attempt is a full {@link _openUnitOnce}
@@ -408,7 +431,11 @@ export class SunspecModbusClient {
408
431
  async _openUnit(host, port, unitId, override) {
409
432
  const connectTimeoutMs = override?.connectTimeoutMs ?? this.resilience.connectTimeoutMs;
410
433
  const attempts = (override?.connectRetries ?? this.resilience.connectRetries) + 1;
411
- await retryAsync(() => this._openUnitOnce(host, port, unitId, connectTimeoutMs), {
434
+ // Default ON: a normal connect/reconnect hands the transport BOTH known hosts so a single
435
+ // attempt tolerates DNS/DHCP drift on the first one. probeUnit opts out to stay a fast-fail
436
+ // single-host scan (see probeUnit / _openUnitOnce).
437
+ const useFallbackHosts = override?.useFallbackHosts ?? true;
438
+ await retryAsync(() => this._openUnitOnce(host, port, unitId, connectTimeoutMs, useFallbackHosts), {
412
439
  attempts,
413
440
  delayMs: this.resilience.connectRetryDelayMs,
414
441
  onRetry: (error, attempt) => console.warn(`SunspecModbusClient: connect to ${host}:${port} unit ${unitId} failed ` +
@@ -420,15 +447,28 @@ export class SunspecModbusClient {
420
447
  * Open a new Modbus instance for one unit ID and wire up its fault-tolerant reader. Bounds the
421
448
  * connect at `connectTimeoutMs`. On any failure, the just-opened instance (if any) is closed so
422
449
  * we never leak. Caller must hold the connection lock and ensure the unit is not already open.
423
- */
424
- async _openUnitOnce(host, port, unitId, connectTimeoutMs = this.resilience.connectTimeoutMs) {
450
+ *
451
+ * When `useFallbackHosts` is true (the connect/reconnect default), the transport is handed the
452
+ * full host list from {@link buildConnectHosts} — the attempt's primary target plus the other
453
+ * known host — so one connect() tolerates DNS/DHCP drift on the first host in-band, rather than
454
+ * waiting for the client's own sequential primary→secondary retry. The transport walks the list
455
+ * in order, each host bounded by `timeout` (connectTimeoutMs); we scale our own outer budget by
456
+ * the host count so a legitimate multi-host walk isn't aborted mid-fallback. probeUnit passes
457
+ * false to keep speculative RS485 scans a fast-fail single-host probe.
458
+ */
459
+ async _openUnitOnce(host, port, unitId, connectTimeoutMs = this.resilience.connectTimeoutMs, useFallbackHosts = true) {
425
460
  let candidate = null;
461
+ const hosts = useFallbackHosts ? this.buildConnectHosts(host) : host;
462
+ const hostCount = Array.isArray(hosts) ? hosts.length : 1;
463
+ // Each host in the list gets its own `timeout`; bound the whole walk at count × budget so we
464
+ // don't kill a genuine fallback to the second host with the single-host budget.
465
+ const overallBudgetMs = connectTimeoutMs * hostCount;
426
466
  try {
427
467
  // Enforce the connect budget ourselves in addition to forwarding it as the transport's
428
468
  // `timeout`: the transport applies it to the TCP handshake, but a sleeping/half-open peer
429
469
  // can still leave the returned promise pending — bound it independently.
430
- candidate = await this.withTimeout('connect', unitId, connectTimeoutMs, () => this.energyApp.useModbus().connect({
431
- host,
470
+ candidate = await this.withTimeout('connect', unitId, overallBudgetMs, () => this.energyApp.useModbus().connect({
471
+ host: hosts,
432
472
  port,
433
473
  unitId,
434
474
  timeout: connectTimeoutMs,
package/dist/version.d.ts CHANGED
@@ -5,7 +5,7 @@
5
5
  /**
6
6
  * Current version of the enyo Energy App SDK.
7
7
  */
8
- export declare const SDK_VERSION = "0.0.102";
8
+ export declare const SDK_VERSION = "0.0.103";
9
9
  /**
10
10
  * Gets the current SDK version.
11
11
  * @returns The semantic version string of the SDK
package/dist/version.js CHANGED
@@ -5,7 +5,7 @@
5
5
  /**
6
6
  * Current version of the enyo Energy App SDK.
7
7
  */
8
- export const SDK_VERSION = '0.0.102';
8
+ export const SDK_VERSION = '0.0.103';
9
9
  /**
10
10
  * Gets the current SDK version.
11
11
  * @returns The semantic version string of the SDK
package/package.json CHANGED
@@ -1,6 +1,6 @@
1
1
  {
2
2
  "name": "@enyo-energy/sunspec-sdk",
3
- "version": "0.0.102",
3
+ "version": "0.0.103",
4
4
  "description": "enyo Energy Sunspec SDK",
5
5
  "type": "module",
6
6
  "main": "dist/index.js",
@@ -40,8 +40,8 @@
40
40
  "vitest": "^2.1.9"
41
41
  },
42
42
  "dependencies": {
43
- "@enyo-energy/appliance-calibration": "0.0.2",
44
- "@enyo-energy/energy-app-sdk": "^0.0.177"
43
+ "@enyo-energy/appliance-calibration": "0.0.3",
44
+ "@enyo-energy/energy-app-sdk": "^0.0.180"
45
45
  },
46
46
  "volta": {
47
47
  "node": "22.17.0"