@enyo-energy/sunspec-sdk 0.0.101 → 0.0.102

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
@@ -708,7 +708,16 @@ class SunspecModbusClient {
708
708
  */
709
709
  async detectSunspecBaseAddress(unitId, customBaseAddress) {
710
710
  const instance = this.getInstance(unitId);
711
- // If custom base address provided, try it first (1-based, then 0-based variant)
711
+ // If a custom base address is provided, try it first (0-based, then 1-based variant).
712
+ //
713
+ // A custom base is only a real SunSpec anchor for a device whose map genuinely starts
714
+ // there. It is NOT an anchor when it points at a *model block* inside a shared unit —
715
+ // e.g. a SolarEdge meter block (~40188) co-resident with the inverter on unit 1: the
716
+ // "SunS" marker lives ONLY at the unit's SunSpec root (40000/40001), never at the meter
717
+ // block. So a miss here must NOT fail discovery; fall through to the standard root probe
718
+ // below. (This is exactly the reconnect path that used to strand the meter — its
719
+ // rediscovery threw "not SunSpec compliant" at 40188, returned no models, and poisoned
720
+ // the shared socket, dragging the inverter offline too.)
712
721
  if (customBaseAddress !== undefined) {
713
722
  console.log(`Detect models for custom base address '${customBaseAddress}' ...`);
714
723
  // Try 0-based at custom address
@@ -741,41 +750,44 @@ class SunspecModbusClient {
741
750
  catch (error) {
742
751
  console.debug(`Could not read SunS at ${customBaseAddress + 1}:`, error);
743
752
  }
753
+ console.debug(`No "SunS" marker at custom base ${customBaseAddress}/${customBaseAddress + 1} on unit ${unitId} — ` +
754
+ `falling back to the standard SunSpec root (40001/40000). Expected when the custom base points at a ` +
755
+ `model block inside a shared unit (e.g. a co-resident meter), whose anchor is the unit root.`);
744
756
  }
745
- else {
746
- // Try 1-based addressing first (most common)
747
- try {
748
- const sunspecId = await this.runExclusive(unitId, () => instance.readRegisterStringValue(40001, 2));
749
- if (sunspecId.includes('SunS')) {
750
- console.log('Detected 1-based addressing mode (base address: 40001)');
751
- return {
752
- baseAddress: 40001,
753
- isZeroBased: false,
754
- nextAddress: 40003
755
- };
756
- }
757
- }
758
- catch (error) {
759
- console.debug('Could not read SunS at 40001:', error);
760
- }
761
- // Try 0-based addressing
762
- try {
763
- const sunspecId = await this.runExclusive(unitId, () => instance.readRegisterStringValue(40000, 2));
764
- if (sunspecId.includes('SunS')) {
765
- console.log('Detected 0-based addressing mode (base address: 40000)');
766
- return {
767
- baseAddress: 40000,
768
- isZeroBased: true,
769
- nextAddress: 40002
770
- };
771
- }
757
+ // Standard SunSpec root probe. Runs when no custom base was given, OR as the fallback
758
+ // when the custom base carried no marker. Try 1-based (40001) first (most common), then
759
+ // 0-based (40000).
760
+ try {
761
+ const sunspecId = await this.runExclusive(unitId, () => instance.readRegisterStringValue(40001, 2));
762
+ if (sunspecId.includes('SunS')) {
763
+ console.log('Detected 1-based addressing mode (base address: 40001)');
764
+ return {
765
+ baseAddress: 40001,
766
+ isZeroBased: false,
767
+ nextAddress: 40003
768
+ };
772
769
  }
773
- catch (error) {
774
- console.debug('Could not read SunS at 40000:', error);
770
+ }
771
+ catch (error) {
772
+ console.debug('Could not read SunS at 40001:', error);
773
+ }
774
+ // Try 0-based addressing
775
+ try {
776
+ const sunspecId = await this.runExclusive(unitId, () => instance.readRegisterStringValue(40000, 2));
777
+ if (sunspecId.includes('SunS')) {
778
+ console.log('Detected 0-based addressing mode (base address: 40000)');
779
+ return {
780
+ baseAddress: 40000,
781
+ isZeroBased: true,
782
+ nextAddress: 40002
783
+ };
775
784
  }
776
785
  }
786
+ catch (error) {
787
+ console.debug('Could not read SunS at 40000:', error);
788
+ }
777
789
  const addressesChecked = customBaseAddress !== undefined
778
- ? `${customBaseAddress}, ${customBaseAddress + 1}`
790
+ ? `${customBaseAddress}, ${customBaseAddress + 1}, 40001, 40000`
779
791
  : '40000 or 40001';
780
792
  throw new Error(`Device is not SunSpec compliant - "SunS" identifier not found at addresses ${addressesChecked}`);
781
793
  }
@@ -786,29 +798,35 @@ class SunspecModbusClient {
786
798
  async discoverModels(unitId, customBaseAddress) {
787
799
  const instance = this.getInstance(unitId);
788
800
  const models = this.getModelsMap(unitId);
789
- models.clear();
790
801
  const modelList = this.getModelList(unitId);
791
- modelList.length = 0;
792
802
  const maxAddress = 50000; // Safety limit
793
- let currentAddress = 0;
794
803
  console.log(`Starting Sunspec model discovery for unit ${unitId}...`);
795
804
  // Probe for the SunS identifier first. A missing identifier means the unit ID isn't a
796
805
  // SunSpec device — common during unit-ID scans — and is logged at debug level so probes
797
806
  // don't surface as errors. Mid-scan failures below remain at error level since they
798
807
  // indicate a partial / malformed SunSpec map.
808
+ //
809
+ // IMPORTANT: we discover into TEMP buffers and only commit into the stored map once the
810
+ // walk yields at least one model. A reconnect probe can transiently fail (e.g. a single-
811
+ // session SolarEdge endpoint drops the socket with ECONNRESET on the first read after
812
+ // accepting the connection). Clearing the stored map up-front — as this used to — turned
813
+ // that blip into "no usable models", which trips tryReconnect()'s gate into invalidating
814
+ // a unit whose model map was perfectly good a moment ago. Preserving the last known-good
815
+ // map keeps a genuinely-connected sibling alive; a device that is really gone is still
816
+ // caught by read-health (isHealthy()).
799
817
  let addressInfo;
800
818
  try {
801
819
  addressInfo = await this.detectSunspecBaseAddress(unitId, customBaseAddress);
802
820
  }
803
821
  catch (error) {
804
822
  console.debug(`No SunSpec device at unit ${unitId}: ${error}`);
805
- // Discovery summary at line 594 below is the info-level outcome.
806
- // This 0-models branch is the same outcome as a normal "no device found",
807
- // covered already by the debug above. Keep at debug.
808
- console.debug(`Discovery complete for unit ${unitId}. Found 0 models: []`);
823
+ // Same outcome as a normal "no device found"; keep at debug. Do NOT wipe the stored
824
+ // map — return it untouched so a transient probe failure can't erase good discovery.
825
+ console.debug(`Discovery incomplete for unit ${unitId}; keeping ${models.size} previously-discovered model(s).`);
809
826
  return models;
810
827
  }
811
- currentAddress = addressInfo.nextAddress;
828
+ const discovered = [];
829
+ let currentAddress = addressInfo.nextAddress;
812
830
  try {
813
831
  while (currentAddress < maxAddress) {
814
832
  const buffer = await this.runExclusive(unitId, () => instance.readHoldingRegisters(currentAddress, 2));
@@ -824,19 +842,12 @@ class SunspecModbusClient {
824
842
  console.debug(`Found end marker at address ${currentAddress}`);
825
843
  break;
826
844
  }
827
- // Store discovered model
828
845
  const model = {
829
846
  id: modelId,
830
847
  address: currentAddress,
831
848
  length: modelLength
832
849
  };
833
- // Keep the FIRST (lowest-address) instance per id in the keyed directory so
834
- // findModel() resolves to the device's own block. Record every instance —
835
- // including repeats like a meter's Common (id 1) — in the ordered list.
836
- if (!models.has(modelId)) {
837
- models.set(modelId, model);
838
- }
839
- modelList.push(model);
850
+ discovered.push(model);
840
851
  // Per-model discovery step. The end-of-discovery summary below is the
841
852
  // info-level outcome; the per-model walk is debug-only.
842
853
  console.debug(`Discovered Model ${modelId} at address ${currentAddress} with length ${modelLength} (unit ${unitId})`);
@@ -847,6 +858,24 @@ class SunspecModbusClient {
847
858
  catch (error) {
848
859
  console.error(`Error during model discovery at address ${currentAddress} (unit ${unitId}): ${error}`);
849
860
  }
861
+ if (discovered.length > 0) {
862
+ // Commit the fresh discovery atomically. Keep the FIRST (lowest-address) instance per
863
+ // id in the keyed directory so findModel() resolves to the device's own block; record
864
+ // every instance — including repeats like a meter's Common (id 1) — in the ordered list.
865
+ models.clear();
866
+ modelList.length = 0;
867
+ for (const model of discovered) {
868
+ if (!models.has(model.id)) {
869
+ models.set(model.id, model);
870
+ }
871
+ modelList.push(model);
872
+ }
873
+ }
874
+ else {
875
+ // The anchor answered but the walk yielded nothing (e.g. the socket dropped right
876
+ // after the SunS probe). Preserve the last known-good map rather than clobbering it.
877
+ console.debug(`Discovery for unit ${unitId} yielded no models; keeping ${models.size} previously-discovered model(s).`);
878
+ }
850
879
  // Report every instance in address order so repeated ids (e.g. two Common blocks, or
851
880
  // multiple meters) are visible — models.size would hide them behind the unique keys.
852
881
  console.log(`Discovery complete for unit ${unitId}. Found ${modelList.length} model instance(s): [${modelList.map(m => m.id).join(', ')}]`);
@@ -988,12 +1017,87 @@ class SunspecModbusClient {
988
1017
  return value;
989
1018
  }
990
1019
  /**
991
- * Helper to read register value(s) using the fault-tolerant reader with data type conversion
1020
+ * Read a contiguous span of `quantity` registers starting at `address` in a single logical
1021
+ * transaction — chunked at the 125-register Modbus limit and serialized on the unit's socket so no
1022
+ * other frame interleaves between chunks. FC03 holding registers by default; FC04 input registers
1023
+ * when `useInputRegisters` is true. The SunSpec model readers use {@link readModelBlock}; this is
1024
+ * the equivalent for callers reading a hand-defined block (see {@link SunspecCustomDevice}). Decode
1025
+ * individual fields out of the returned buffer with {@link decodeBlockValue}.
1026
+ */
1027
+ async readRegisterBlock(unitId, address, quantity, useInputRegisters = false) {
1028
+ const reader = this.getReader(unitId);
1029
+ const MAX_REGISTERS_PER_READ = 125;
1030
+ try {
1031
+ const chunks = await this.runExclusive(unitId, async () => {
1032
+ const acc = [];
1033
+ for (let offset = 0; offset < quantity; offset += MAX_REGISTERS_PER_READ) {
1034
+ const count = Math.min(MAX_REGISTERS_PER_READ, quantity - offset);
1035
+ let result;
1036
+ if (useInputRegisters) {
1037
+ if (!reader.readInputRegisters) {
1038
+ throw new Error(`Reader for unit ${unitId} does not support FC04 input registers`);
1039
+ }
1040
+ result = await reader.readInputRegisters(address + offset, count);
1041
+ }
1042
+ else {
1043
+ result = await reader.readHoldingRegisters(address + offset, count);
1044
+ }
1045
+ if (!result.success || !result.value) {
1046
+ throw new Error(`Failed to read register block at address ${address + offset} (unit ${unitId}): ${result.error?.message || 'Unknown error'}`);
1047
+ }
1048
+ acc.push(result.value);
1049
+ }
1050
+ return acc;
1051
+ });
1052
+ this.connectionHealth.recordSuccess();
1053
+ return chunks.length === 1 ? chunks[0] : Buffer.concat(chunks);
1054
+ }
1055
+ catch (error) {
1056
+ this.connectionHealth.recordFailure(error);
1057
+ throw error;
1058
+ }
1059
+ }
1060
+ /**
1061
+ * Decode a typed value out of a buffer returned by {@link readRegisterBlock}, at a register offset
1062
+ * from the block start. A thin public wrapper over the same block-extraction the SunSpec model
1063
+ * readers use internally.
1064
+ */
1065
+ decodeBlockValue(buffer, registerOffset, dataType, quantity = 1) {
1066
+ return this.extractValue(buffer, registerOffset, dataType, quantity);
1067
+ }
1068
+ /**
1069
+ * Helper to read holding register value(s) (FC03) using the fault-tolerant reader with data type
1070
+ * conversion.
992
1071
  */
993
1072
  async readRegisterValue(unitId, address, quantity = 1, dataType) {
1073
+ return this.readTypedRegisters(unitId, address, quantity, dataType, false);
1074
+ }
1075
+ /**
1076
+ * Helper to read input register value(s) (FC04) using the fault-tolerant reader with data type
1077
+ * conversion. SunSpec itself never uses input registers, but plain-Modbus devices behind a
1078
+ * {@link SunspecCustomDevice} may expose live values there. Throws if the transport's reader does
1079
+ * not implement `readInputRegisters`.
1080
+ */
1081
+ async readInputRegisterValue(unitId, address, quantity = 1, dataType) {
1082
+ return this.readTypedRegisters(unitId, address, quantity, dataType, true);
1083
+ }
1084
+ /**
1085
+ * Shared body of {@link readRegisterValue} / {@link readInputRegisterValue}. Runs the read under
1086
+ * the unit's transaction lock (so it inherits the timeout/poison/staleness resilience) and records
1087
+ * connection health on both success and failure.
1088
+ */
1089
+ async readTypedRegisters(unitId, address, quantity, dataType, useInputRegisters) {
994
1090
  const reader = this.getReader(unitId);
995
1091
  try {
996
- const result = await this.runExclusive(unitId, () => reader.readHoldingRegisters(address, quantity));
1092
+ const result = await this.runExclusive(unitId, () => {
1093
+ if (useInputRegisters) {
1094
+ if (!reader.readInputRegisters) {
1095
+ throw new Error(`Reader for unit ${unitId} does not support FC04 input registers`);
1096
+ }
1097
+ return reader.readInputRegisters(address, quantity);
1098
+ }
1099
+ return reader.readHoldingRegisters(address, quantity);
1100
+ });
997
1101
  // Check if the read was successful
998
1102
  if (!result.success || !result.value) {
999
1103
  throw new Error(`Failed to read register at address ${address}: ${result.error?.message || 'Unknown error'}`);
@@ -349,9 +349,38 @@ export declare class SunspecModbusClient {
349
349
  */
350
350
  private extractValue;
351
351
  /**
352
- * Helper to read register value(s) using the fault-tolerant reader with data type conversion
352
+ * Read a contiguous span of `quantity` registers starting at `address` in a single logical
353
+ * transaction — chunked at the 125-register Modbus limit and serialized on the unit's socket so no
354
+ * other frame interleaves between chunks. FC03 holding registers by default; FC04 input registers
355
+ * when `useInputRegisters` is true. The SunSpec model readers use {@link readModelBlock}; this is
356
+ * the equivalent for callers reading a hand-defined block (see {@link SunspecCustomDevice}). Decode
357
+ * individual fields out of the returned buffer with {@link decodeBlockValue}.
358
+ */
359
+ readRegisterBlock(unitId: number, address: number, quantity: number, useInputRegisters?: boolean): Promise<Buffer>;
360
+ /**
361
+ * Decode a typed value out of a buffer returned by {@link readRegisterBlock}, at a register offset
362
+ * from the block start. A thin public wrapper over the same block-extraction the SunSpec model
363
+ * readers use internally.
364
+ */
365
+ decodeBlockValue(buffer: Buffer, registerOffset: number, dataType: EnergyAppModbusDataType, quantity?: number): number | string | number[];
366
+ /**
367
+ * Helper to read holding register value(s) (FC03) using the fault-tolerant reader with data type
368
+ * conversion.
353
369
  */
354
370
  readRegisterValue(unitId: number, address: number, quantity: number | undefined, dataType: EnergyAppModbusDataType): Promise<number | string | number[]>;
371
+ /**
372
+ * Helper to read input register value(s) (FC04) using the fault-tolerant reader with data type
373
+ * conversion. SunSpec itself never uses input registers, but plain-Modbus devices behind a
374
+ * {@link SunspecCustomDevice} may expose live values there. Throws if the transport's reader does
375
+ * not implement `readInputRegisters`.
376
+ */
377
+ readInputRegisterValue(unitId: number, address: number, quantity: number | undefined, dataType: EnergyAppModbusDataType): Promise<number | string | number[]>;
378
+ /**
379
+ * Shared body of {@link readRegisterValue} / {@link readInputRegisterValue}. Runs the read under
380
+ * the unit's transaction lock (so it inherits the timeout/poison/staleness resilience) and records
381
+ * connection health on both success and failure.
382
+ */
383
+ private readTypedRegisters;
355
384
  /**
356
385
  * Helper to write register value(s)
357
386
  */
@@ -9,7 +9,7 @@ exports.getSdkVersion = getSdkVersion;
9
9
  /**
10
10
  * Current version of the enyo Energy App SDK.
11
11
  */
12
- exports.SDK_VERSION = '0.0.101';
12
+ exports.SDK_VERSION = '0.0.102';
13
13
  /**
14
14
  * Gets the current SDK version.
15
15
  * @returns The semantic version string of the SDK
@@ -5,7 +5,7 @@
5
5
  /**
6
6
  * Current version of the enyo Energy App SDK.
7
7
  */
8
- export declare const SDK_VERSION = "0.0.101";
8
+ export declare const SDK_VERSION = "0.0.102";
9
9
  /**
10
10
  * Gets the current SDK version.
11
11
  * @returns The semantic version string of the SDK
@@ -1,4 +1,4 @@
1
- import { type IRetryConfig, type SunspecBatteryBaseData, SunspecBatteryCapability, type SunspecBatteryControls, type SunspecBatteryData, type SunspecBatteryFeatureMode, type SunspecInverterData, SunspecInverterCapability, SunspecPvPowerSource, SunspecPvPowerOrigin, type SunspecInverterReading, type SunspecBatteryReading, SunspecMeterCapability, type SunspecMPPTData, SunspecStorageMode } from "./sunspec-interfaces.js";
1
+ import { type IRetryConfig, type SunspecBatteryBaseData, SunspecBatteryCapability, type SunspecBatteryControls, type SunspecBatteryData, type SunspecBatteryFeatureMode, type SunspecInverterData, SunspecInverterCapability, SunspecPvPowerSource, SunspecPvPowerOrigin, type SunspecInverterReading, type SunspecBatteryReading, SunspecMeterCapability, type SunspecMPPTData, SunspecStorageMode, type SunspecCustomDeviceConfig } from "./sunspec-interfaces.js";
2
2
  import { ApplianceManager, EnergyApp } from "@enyo-energy/energy-app-sdk";
3
3
  import { type EnyoAppliance, type EnyoApplianceErrorCode, EnyoApplianceName } from "@enyo-energy/energy-app-sdk/dist/types/enyo-appliance.js";
4
4
  import { EnyoNetworkDevice } from "@enyo-energy/energy-app-sdk/dist/types/enyo-network-device.js";
@@ -68,6 +68,20 @@ export declare abstract class BaseSunspecDevice {
68
68
  * Ensure the Sunspec client is connected and models are discovered
69
69
  */
70
70
  protected ensureConnected(): Promise<void>;
71
+ /**
72
+ * Populate the per-unit model directory after the socket opens. Default: run SunSpec model
73
+ * discovery. Devices that read a hand-defined static register map instead of a discovered SunSpec
74
+ * directory (see {@link SunspecCustomDevice}) override this to a no-op.
75
+ */
76
+ protected discoverAfterConnect(): Promise<void>;
77
+ /**
78
+ * Validate that a just-completed reconnect actually restored a usable device. Default: re-run
79
+ * SunSpec discovery and check it against {@link getRequiredModelIds} (a socket that opens but comes
80
+ * back with no usable models means the gateway accepted the connection before it was ready to
81
+ * answer the scan). Returns false to treat the reconnect as failed so the backoff schedule keeps
82
+ * running. Discovery-less devices override this to just confirm the socket is open.
83
+ */
84
+ protected revalidateAfterReconnect(): Promise<boolean>;
71
85
  /**
72
86
  * Attempt a reconnection if the tiered retry schedule allows it.
73
87
  * Called from readData() when the device is disconnected.
@@ -735,4 +749,70 @@ export declare class SunspecMeter extends BaseSunspecDevice {
735
749
  */
736
750
  readData(clockId: string, resolution: EnyoDataBusMessageResolution): Promise<EnyoDataBusMessage[]>;
737
751
  }
752
+ /**
753
+ * A generic, pre-configured Modbus device that plugs into the exact same resilient lifecycle as the
754
+ * SunSpec devices — the per-device {@link ConnectionRetryManager}, {@link tryReconnect} tiered backoff,
755
+ * {@link markOffline}/{@link reassertConnectedIfRecovered} shared-socket healing, and the client's
756
+ * per-transaction timeout/poison/staleness guards — but reads a **hand-defined static register map**
757
+ * instead of a discovered SunSpec model directory.
758
+ *
759
+ * It emulates a configurable {@link SunspecCustomDeviceConfig.role} (`meter` | `inverter` | `battery`):
760
+ * the role selects the appliance type created on connect and which EnyoDataBus values message
761
+ * {@link readData} publishes, and each {@link SunspecCustomRegister} maps onto one numeric field of
762
+ * that message. Supports FC03 holding registers (default), FC04 input registers, and writes.
763
+ *
764
+ * Discovery is fully bypassed: {@link connect} opens the socket only, and the reconnect path is
765
+ * validated by socket liveness rather than a SunSpec scan.
766
+ */
767
+ export declare class SunspecCustomDevice extends BaseSunspecDevice {
768
+ private readonly config;
769
+ /** Read plan derived once from the static register map (see {@link planBlocks}). */
770
+ private plannedBlocks?;
771
+ constructor(energyApp: EnergyApp, name: EnyoApplianceName[], networkDevice: EnyoNetworkDevice, sunspecClient: SunspecModbusClient, applianceManager: ApplianceManager, config: SunspecCustomDeviceConfig, unitId?: number, port?: number, baseAddress?: number, retryConfig?: IRetryConfig, appliance?: EnyoAppliance, useTls?: boolean);
772
+ /**
773
+ * No SunSpec model directory to build — this device reads pre-defined static addresses. Overriding
774
+ * the base discovery hook to a no-op is what lets {@link ensureConnected}/{@link connect} open the
775
+ * socket without a SunS scan.
776
+ */
777
+ protected discoverAfterConnect(): Promise<void>;
778
+ /**
779
+ * A reconnect is usable as soon as the socket is open again — there is no model map to revalidate.
780
+ * Without this override the base default would run SunSpec discovery, find nothing, and treat every
781
+ * reconnect as a permanent failure.
782
+ */
783
+ protected revalidateAfterReconnect(): Promise<boolean>;
784
+ /**
785
+ * Connect the underlying socket (no discovery) and create/update the appliance for the configured
786
+ * role. Identity metadata comes from {@link SunspecCustomDeviceConfig.identity} since there is no
787
+ * SunSpec Common block to read it from.
788
+ */
789
+ connect(): Promise<void>;
790
+ disconnect(): Promise<void>;
791
+ readData(clockId: string, resolution: EnyoDataBusMessageResolution): Promise<EnyoDataBusMessage[]>;
792
+ /**
793
+ * Write a value to a pre-configured writable register. Delegates to the client's resilient
794
+ * {@link SunspecModbusClient.writeRegisterValue}.
795
+ */
796
+ writeCustomRegister(name: string, value: number | number[]): Promise<boolean>;
797
+ /**
798
+ * Read every configured register as a small number of block reads and extract each register from
799
+ * its block buffer by offset (mirroring the SunSpec model-block read). Applies the fixed decimal
800
+ * scaling and returns a field → value map. Non-numeric reads (e.g. a `string` dataType that can't
801
+ * populate a numeric databus field) are skipped with a warning.
802
+ */
803
+ private readConfiguredRegisters;
804
+ /** Lazily compute and cache the block read plan; the register map is static per device. */
805
+ private getPlannedBlocks;
806
+ /**
807
+ * Group the configured registers (separately per function code) sorted by address, coalescing them
808
+ * — across gaps — into blocks no wider than {@link SunspecCustomDeviceConfig.blockSize}. A new block
809
+ * starts whenever adding the next register would exceed that span. Each block records its members'
810
+ * offsets so a single read can be sliced into all of them.
811
+ */
812
+ private planBlocks;
813
+ private buildRoleMessage;
814
+ private buildMeterMessage;
815
+ private buildInverterMessage;
816
+ private buildBatteryMessage;
817
+ }
738
818
  export {};