@enyo-energy/energy-app-sdk 1.0.0 → 1.2.0

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
package/README.md CHANGED
@@ -712,20 +712,52 @@ Manage charging sessions:
712
712
  ```typescript
713
713
  const charging = energyApp.useCharge();
714
714
 
715
- // Start charging session
716
- const sessionId = await charging.startCharge({
717
- vehicleId: 'vehicle-123',
715
+ // Open a session when the charger reports a StartTransaction
716
+ const charge = await charging.startCharge({
717
+ applianceId: 'appliance-42',
718
+ transactionId: 'tx-1',
719
+ meterStartValueWh: 1_204_000,
718
720
  connectorId: 1,
719
- maxPowerKw: 22
720
721
  });
721
722
 
722
- // Get active sessions
723
- const sessions = await charging.getActiveSessions();
723
+ // Close it when the charger reports a StopTransaction
724
+ const finished = await charging.stopCharge(charge.id, {
725
+ meterEndValueWh: 1_215_500,
726
+ energyDeliveredWh: 11_500,
727
+ });
728
+ console.log(`${finished.totalEnergyKwh} kWh for ${finished.paidPriceEuroCent} ct`);
729
+
730
+ // The session a charger is running right now, if any
731
+ const active = await charging.findActiveCharge('appliance-42');
724
732
 
725
- // Stop charging
726
- await charging.stopCharge(sessionId);
733
+ // A session that spans several OCPP transactions (reconnect, re-authorization)
734
+ await charging.addTransactionIdToActiveCharge('appliance-42', 'tx-2');
735
+
736
+ // Read the history
737
+ const completed = await charging.list({
738
+ applianceId: 'appliance-42',
739
+ status: EnyoChargeStatus.Completed,
740
+ });
727
741
  ```
728
742
 
743
+ **Energy and cost totals are the host's to compute, never the app's.**
744
+ `stopCharge()` derives `totalEnergyKwh` and `paidPriceEuroCent` from the
745
+ session's meter readings and the electricity tariff in force while the energy
746
+ flowed. Pass readings — `meterEndValueWh`, and `energyDeliveredWh` when the
747
+ charger reports it — and let the host price them. An app that computes its own
748
+ totals makes the customer's bill depend on which app closed the session.
749
+
750
+ The same division applies to the samples in `meterValues`: leave `pricePerKwh`
751
+ and `chargingCostEuro` unset and the host resolves the tariff for each sample's
752
+ 15-minute slot itself. `powerW` and `voltageL1..L3` are optional — write them
753
+ when the charger reports them; when omitted the host keeps whatever it already
754
+ recorded for that timestamp.
755
+
756
+ `startCharge()` is idempotent on `applianceId` + `transactionId`, so a repeated
757
+ StartTransaction returns the running session instead of opening a second one.
758
+ `save()` remains a whole-object update for a session that already exists; it
759
+ offers no uniqueness guarantee, so do not open sessions with it.
760
+
729
761
  React to charging sessions as they happen:
730
762
 
731
763
  ```typescript
@@ -47,14 +47,18 @@ const ANY_MODEL = '*';
47
47
  /**
48
48
  * A short human-readable label for a guide, for use in messages.
49
49
  *
50
- * Prefers the first translated title, since ids are not required at guide level;
51
- * falls back to the start variant so a titleless guide is still identifiable.
50
+ * Prefers {@link EnyoOnboardingV2Guide.name} — it is the handle the author will
51
+ * search for — then the first translated title, then the start variant, so a
52
+ * guide with neither a name nor a title is still identifiable.
52
53
  *
53
54
  * @param guide - The guide to label.
54
55
  * @param index - Its position in the answer's `guides` array.
55
56
  * @returns A message prefix such as ``guides[2] ("Wallbox über OCPP")``.
56
57
  */
57
58
  function guideLabel(guide, index) {
59
+ const name = guide.name?.trim();
60
+ if (name)
61
+ return `guides[${index}] ("${name}")`;
58
62
  const title = guide.title?.[0]?.value;
59
63
  return `guides[${index}] (${title ? `"${title}"` : (guide.startVariant ?? '?')})`;
60
64
  }
@@ -122,6 +126,9 @@ function validateOnboardingV2GuidesResult(result, context) {
122
126
  }
123
127
  // Which guide(s) claimed each binding, so a collision can name both sides.
124
128
  const claimedBy = new Map();
129
+ // Same, for the explicit `name` handles — a duplicate makes an app unable to
130
+ // say which of the two it means.
131
+ const namedBy = new Map();
125
132
  for (const [i, guide] of result.guides.entries()) {
126
133
  const at = guideLabel(guide, i);
127
134
  const guideResult = (0, onboarding_v2_validators_js_1.validateOnboardingGuideV2)(guide, context);
@@ -134,6 +141,17 @@ function validateOnboardingV2GuidesResult(result, context) {
134
141
  else if (!guide.modelIds?.length) {
135
142
  warnings.push(`${at}: no modelIds — this guide applies to every model of "${guide.vendorId}".`);
136
143
  }
144
+ const name = guide.name?.trim();
145
+ if (name) {
146
+ const previouslyNamed = namedBy.get(name);
147
+ if (previouslyNamed) {
148
+ errors.push(`${at}: name "${name}" is already used by ${previouslyNamed} — ` +
149
+ 'a name is how an app addresses one specific guide, so two guides cannot share one.');
150
+ }
151
+ else {
152
+ namedBy.set(name, at);
153
+ }
154
+ }
137
155
  for (const key of bindingKeys(guide)) {
138
156
  const previous = claimedBy.get(key);
139
157
  if (previous) {
@@ -148,6 +148,8 @@ function validateOnboardingGuideV2(guide, context) {
148
148
  }
149
149
  validateNetworkScanFlag(guide, warnings);
150
150
  validateApplianceBinding(guide, errors, warnings);
151
+ validateUserNotification(guide, warnings);
152
+ validateGuideName(guide, errors, warnings);
151
153
  return { ok: errors.length === 0, errors, warnings };
152
154
  }
153
155
  /**
@@ -681,6 +683,63 @@ function validateApplianceBinding(guide, errors, warnings) {
681
683
  '` guide binds an existing appliance.');
682
684
  }
683
685
  }
686
+ /**
687
+ * Checks {@link EnyoOnboardingV2Guide.name} is usable as a handle.
688
+ *
689
+ * The property is optional — a guide that never needs to be addressed does not
690
+ * need one, and the host falls back to a name derived from the guide's
691
+ * bindings. But a name that is *present* and blank is worse than absent: it
692
+ * looks like a handle at the call site and matches nothing, so
693
+ * `removeOnboardingGuide('')` would silently do nothing. That is an error.
694
+ *
695
+ * Whitespace around a name is trimmed by the host before it is compared, so
696
+ * `" setup "` and `"setup"` are the same handle; a name carrying padding is
697
+ * only warned about, since it works but will not look like what the author
698
+ * typed in a log line.
699
+ *
700
+ * @param guide - The guide being validated.
701
+ * @param errors - Collector for blocking problems.
702
+ * @param warnings - Collector for advisory problems.
703
+ */
704
+ function validateGuideName(guide, errors, warnings) {
705
+ if (guide.name === undefined)
706
+ return;
707
+ if (typeof guide.name !== 'string' || guide.name.trim() === '') {
708
+ errors.push('`name` is present but blank — a guide either carries a handle an app can address ' +
709
+ 'it by or omits the property entirely; an empty name matches nothing.');
710
+ return;
711
+ }
712
+ if (guide.name !== guide.name.trim()) {
713
+ warnings.push(`\`name\` "${guide.name}" has leading or trailing whitespace, which the host trims — ` +
714
+ 'the guide is addressed as `' + guide.name.trim() + '`.');
715
+ }
716
+ }
717
+ /**
718
+ * Checks {@link EnyoOnboardingV2Guide.notifyUser} against the guide's
719
+ * {@link EnyoOnboardingV2Guide.startVariant}.
720
+ *
721
+ * The flag asks the host to tell the end customer that a maintenance run is
722
+ * happening on their appliance, so it only means anything on
723
+ * {@link EnyoOnboardingV2StartVariant.Maintenance}. An installation guide has
724
+ * nobody to notify — the appliance does not exist yet and the installer is
725
+ * standing in front of the device — so setting it there is a warning, not an
726
+ * error: the host ignores the value, but it is a sign the wrong variant was
727
+ * chosen. Leaving it unset is always fine; it defaults to `false`.
728
+ *
729
+ * @param guide - The guide being validated.
730
+ * @param warnings - Collector for advisory problems.
731
+ */
732
+ function validateUserNotification(guide, warnings) {
733
+ if (guide.notifyUser === undefined)
734
+ return;
735
+ if (guide.startVariant === enyo_onboarding_v2_js_1.EnyoOnboardingV2StartVariant.Maintenance)
736
+ return;
737
+ warnings.push('`notifyUser` is set on a `' +
738
+ `${guide.startVariant}` +
739
+ '` guide and is ignored — only a `' +
740
+ `${enyo_onboarding_v2_js_1.EnyoOnboardingV2StartVariant.Maintenance}` +
741
+ '` guide notifies the end customer about the run.');
742
+ }
684
743
  /**
685
744
  * Checks {@link EnyoOnboardingV2Guide.requiresNetworkScan} against what the guide
686
745
  * actually does.
@@ -88,6 +88,8 @@ __exportStar(require("./types/enyo-heating-rod-appliance.cjs"), exports);
88
88
  __exportStar(require("./types/enyo-charger-appliance.cjs"), exports);
89
89
  __exportStar(require("./types/enyo-charging-card.cjs"), exports);
90
90
  __exportStar(require("./packages/energy-app-charging-card.cjs"), exports);
91
+ __exportStar(require("./types/enyo-charge.cjs"), exports);
92
+ __exportStar(require("./packages/energy-app-charge.cjs"), exports);
91
93
  __exportStar(require("./types/enyo-battery-appliance.cjs"), exports);
92
94
  __exportStar(require("./types/enyo-heatpump-appliance.cjs"), exports);
93
95
  __exportStar(require("./types/enyo-inverter-appliance.cjs"), exports);
@@ -72,6 +72,8 @@ export * from './types/enyo-heating-rod-appliance.cjs';
72
72
  export * from './types/enyo-charger-appliance.cjs';
73
73
  export * from './types/enyo-charging-card.cjs';
74
74
  export * from './packages/energy-app-charging-card.cjs';
75
+ export * from './types/enyo-charge.cjs';
76
+ export * from './packages/energy-app-charge.cjs';
75
77
  export * from './types/enyo-battery-appliance.cjs';
76
78
  export * from './types/enyo-heatpump-appliance.cjs';
77
79
  export * from './types/enyo-inverter-appliance.cjs';
@@ -1,10 +1,94 @@
1
- import { EnyoCharge, EnyoChargeFilter, EnyoDefaultChargeMode } from "../types/enyo-charge.cjs";
1
+ import { EnyoCharge, EnyoChargeFilter, EnyoDefaultChargeMode, EnyoStartChargeRequest, EnyoStopChargeRequest } from "../types/enyo-charge.cjs";
2
2
  /**
3
3
  * Interface for managing charging sessions in enyo packages.
4
4
  * Provides operations for charge session tracking and management.
5
5
  */
6
6
  export interface EnergyAppCharge {
7
- /** Save or update a charging session in the system */
7
+ /**
8
+ * Opens a charging session for an appliance and returns it.
9
+ *
10
+ * Use this to start a session — not {@link save}. `save` writes whatever
11
+ * object it is given and offers no uniqueness guarantee, so two
12
+ * StartTransactions arriving a few milliseconds apart both pass an app-side
13
+ * "is one already active?" check and create two sessions for one plug-in.
14
+ * This call is handled by the host, which holds the invariant that an
15
+ * appliance has at most one active charge.
16
+ *
17
+ * **Idempotent.** When a session is already active for the same
18
+ * `applianceId` + `transactionId`, that session is returned unchanged
19
+ * rather than a second one being created — a repeated StartTransaction is
20
+ * safe. A session that is active on the appliance under a *different*
21
+ * transaction ID is treated as over: the host finalises it with best-effort
22
+ * end values before opening this one. If it is really the same physical
23
+ * session continuing under a new transaction ID (a reconnect, a
24
+ * re-authorization), use {@link addTransactionIdToActiveCharge} instead.
25
+ *
26
+ * The returned charge carries its `id`, so the session can be updated and
27
+ * later stopped without a {@link findActiveCharge} round-trip first.
28
+ *
29
+ * **Required permission:** `Charge`.
30
+ *
31
+ * @param request - What is known at plug-in time.
32
+ * @returns Promise resolving to the started session — or the session that
33
+ * was already running for this appliance and transaction.
34
+ *
35
+ * @example
36
+ * ```typescript
37
+ * const charge = await energyApp.useCharge().startCharge({
38
+ * applianceId,
39
+ * transactionId: ocppTransactionId,
40
+ * meterStartValueWh: meterValue,
41
+ * connectorId: 1,
42
+ * });
43
+ * ```
44
+ */
45
+ startCharge: (request: EnyoStartChargeRequest) => Promise<EnyoCharge>;
46
+ /**
47
+ * Closes a charging session and returns the final record.
48
+ *
49
+ * The host does the arithmetic, and that is the point of this call: it
50
+ * derives {@link EnyoCharge.totalEnergyKwh} and
51
+ * {@link EnyoCharge.paidPriceEuroCent} from the session's meter readings
52
+ * and the electricity tariff in force while the energy flowed, then moves
53
+ * the session to a terminal status and notifies
54
+ * {@link listenForChargeStopped}. An app must not price a session itself —
55
+ * totals computed app-side would differ between apps, and a customer's bill
56
+ * would depend on which app happened to close the charge.
57
+ *
58
+ * Supply readings, not totals: `meterEndValueWh` and, when the charger
59
+ * reports it, `energyDeliveredWh`. Anything an app writes into
60
+ * `paidPriceEuroCent` via {@link save} is overwritten here.
61
+ *
62
+ * Stopping a session that is already in a terminal status is a no-op and
63
+ * returns the stored record — a duplicate StopTransaction will not re-price
64
+ * a finished charge.
65
+ *
66
+ * **Required permission:** `Charge`.
67
+ *
68
+ * @param chargeId - The session to close, as returned by
69
+ * {@link startCharge} or {@link findActiveCharge}.
70
+ * @param request - How the session ended.
71
+ * @returns Promise resolving to the final charge record, totals included.
72
+ *
73
+ * @example
74
+ * ```typescript
75
+ * const finished = await energyApp.useCharge().stopCharge(charge.id, {
76
+ * meterEndValueWh: meterValue,
77
+ * energyDeliveredWh: stopTransaction.energyWh,
78
+ * });
79
+ * console.log(`${finished.totalEnergyKwh} kWh for ${finished.paidPriceEuroCent} ct`);
80
+ * ```
81
+ */
82
+ stopCharge: (chargeId: string, request: EnyoStopChargeRequest) => Promise<EnyoCharge>;
83
+ /**
84
+ * Save or update a charging session in the system.
85
+ *
86
+ * This is a whole-object write for a session that already exists — a
87
+ * changed vehicle, a corrected reading. Use {@link startCharge} to open a
88
+ * session and {@link stopCharge} to close one: calling this without a
89
+ * `chargeId` creates a row with no uniqueness guarantee, and writing
90
+ * terminal values by hand skips the host's energy and cost calculation.
91
+ */
8
92
  save: (charge: Omit<EnyoCharge, 'id'>, chargeId?: string) => Promise<void>;
9
93
  /** Get a list of charging sessions with optional filtering */
10
94
  list: (filter?: EnyoChargeFilter) => Promise<EnyoCharge[]>;
@@ -1,6 +1,28 @@
1
1
  import type { EnyoOnboardingV2GuidesRequest, EnyoOnboardingV2GuidesResult } from '../types/enyo-onboarding-v2-provider.cjs';
2
2
  import type { EnyoOnboardingV2DynamicRequest, EnyoOnboardingV2DynamicResult } from '../types/enyo-onboarding-v2-dynamic.cjs';
3
3
  import type { EnyoOnboardingV2AdditionalSetupRequest, EnyoOnboardingV2AdditionalSetupResult } from '../types/enyo-onboarding-v2-additional-setup.cjs';
4
+ /**
5
+ * Which run of a named guide an app means.
6
+ *
7
+ * A guide name identifies the *flow*; this narrows it to one walk of that flow
8
+ * when more than one can be open at a time. A maintenance guide is bound to an
9
+ * appliance and its runs live in a lane of their own — one per appliance — so
10
+ * that is the only distinction the host needs.
11
+ *
12
+ * Omit it entirely for a guide that has one open run, which is every
13
+ * installation variant.
14
+ */
15
+ export interface EnyoOnboardingV2RunSelector {
16
+ /**
17
+ * The appliance whose run is meant, for a guide bound to one
18
+ * ({@link EnyoOnboardingV2StartVariant.Maintenance}).
19
+ *
20
+ * Omitted on a maintenance guide, the call addresses that guide's single
21
+ * open run when there is exactly one and is rejected when there are
22
+ * several — an ambiguous "complete the run" must not close an arbitrary one.
23
+ */
24
+ applianceId?: string;
25
+ }
4
26
  /**
5
27
  * Handler the host calls to collect every onboarding guide (v2) an app ships.
6
28
  *
@@ -196,6 +218,124 @@ export interface EnergyAppOnboardingV2 {
196
218
  * @returns Promise that resolves once the host has taken the new answer.
197
219
  */
198
220
  refreshOnboardingGuides(): Promise<void>;
221
+ /**
222
+ * Retires one guide by name, without the app restating its whole set.
223
+ *
224
+ * The ordinary way to retire a guide is to leave it out of the next
225
+ * {@link EnyoOnboardingV2GuidesHandler} answer, and that remains the right
226
+ * choice when the app's guide set is a static list in its source. This is
227
+ * for the case that answer cannot express: a guide the app decided to
228
+ * withdraw *now* — a vendor account was unlinked, an appliance it was bound
229
+ * to is gone — where waiting for the host's next pull means an installer
230
+ * can still start a flow the app can no longer serve.
231
+ *
232
+ * Names the guide by its {@link EnyoOnboardingV2Guide.name}, so only a
233
+ * guide that carries one can be retired this way. A guide without a name is
234
+ * addressable only as part of the complete answer.
235
+ *
236
+ * **The handler is still the source of truth.** This drops the guide from
237
+ * the host's cache; it does not stop the app from offering it again. If the
238
+ * handler keeps returning the guide, the next pull brings it back — so
239
+ * remove it from what the handler builds as well, or the retirement lasts
240
+ * only until the next sync.
241
+ *
242
+ * Runs already walking the guide are not touched: a guide is retired for the
243
+ * *next* installer, and pulling a flow out from under one already inside it
244
+ * would strand them mid-installation. Use {@link removeOnboardingRun} to end
245
+ * a run.
246
+ *
247
+ * Removing a guide the host does not know — wrong name, already retired — is
248
+ * a no-op rather than an error.
249
+ *
250
+ * This API is available to every app — it is not permission-gated.
251
+ *
252
+ * @param name - The {@link EnyoOnboardingV2Guide.name} of the guide to retire.
253
+ * @returns Promise that resolves once the host has dropped the guide.
254
+ *
255
+ * @example
256
+ * ```typescript
257
+ * await energyApp.useOnboardingV2().removeOnboardingGuide('vendor-cloud-setup');
258
+ * ```
259
+ */
260
+ removeOnboardingGuide(name: string): Promise<void>;
261
+ /**
262
+ * Marks the run walking a named guide as **completed**.
263
+ *
264
+ * For the flow that finished somewhere other than on the installer's
265
+ * screen. A guide normally completes when the walk reaches a success
266
+ * target — the installer taps through to the end. But an app sometimes
267
+ * learns the goal was met by another route: the wallbox connected over OCPP
268
+ * by itself, the vendor cloud confirmed the pairing, the appliance the
269
+ * maintenance run was servicing reported healthy. Leaving that run open
270
+ * shows the customer an installation still in progress that nobody intends
271
+ * to continue.
272
+ *
273
+ * The run is closed as a **success**: it leaves the "open" set, stops being
274
+ * offered for resumption, and counts as a finished installation. Use
275
+ * {@link removeOnboardingRun} for a flow that ended without achieving
276
+ * anything — the two are not interchangeable, and reporting an abandoned
277
+ * setup as completed is how a broken installation looks fine on a dashboard.
278
+ *
279
+ * Completing a run that is already finished — completed or removed — is a
280
+ * no-op: the first outcome stands, and a late confirmation does not reopen
281
+ * or re-close a run. So is naming a guide with no open run at all.
282
+ *
283
+ * Not permission-gated, like the rest of this API: a guide name is resolved
284
+ * within the calling package, so an app can only reach runs of guides it
285
+ * ships itself.
286
+ *
287
+ * @param name - The {@link EnyoOnboardingV2Guide.name} of the guide whose run
288
+ * should be completed.
289
+ * @param selector - Which run, when the guide can have more than one open.
290
+ * @returns Promise that resolves once the host has closed the run.
291
+ *
292
+ * @example
293
+ * ```typescript
294
+ * // The wallbox connected on its own — the installer never reached the last step.
295
+ * ocpp.onChargePointConnect(async () => {
296
+ * await energyApp.useOnboardingV2().completeOnboardingRun('wallbox-ocpp-setup');
297
+ * });
298
+ * ```
299
+ */
300
+ completeOnboardingRun(name: string, selector?: EnyoOnboardingV2RunSelector): Promise<void>;
301
+ /**
302
+ * Ends the run walking a named guide **without** completing it.
303
+ *
304
+ * The counterpart to {@link completeOnboardingRun}, for a flow that is over
305
+ * but achieved nothing: the device it was setting up was removed, the
306
+ * appliance a maintenance run was servicing no longer exists, the app can no
307
+ * longer serve the guide the run is walking. The run leaves the open set as
308
+ * abandoned rather than successful, so it stops being offered for resumption
309
+ * and is not counted as a finished installation.
310
+ *
311
+ * This ends a *run*, not a guide. The guide stays available and a new run
312
+ * can start on it immediately — that is the point when a stuck run is
313
+ * blocking a fresh attempt, since a device can have only one open run per
314
+ * flow. Use {@link removeOnboardingGuide} to withdraw the flow itself.
315
+ *
316
+ * An installer may be looking at the run when it is removed. Do this because
317
+ * the run genuinely cannot continue, not to tidy up: the screen ends the
318
+ * setup under them, and nothing explains why.
319
+ *
320
+ * Removing a run that is already finished, or naming a guide with no open
321
+ * run, is a no-op.
322
+ *
323
+ * Not permission-gated, like the rest of this API: a guide name is resolved
324
+ * within the calling package, so an app can only reach runs of guides it
325
+ * ships itself.
326
+ *
327
+ * @param name - The {@link EnyoOnboardingV2Guide.name} of the guide whose run
328
+ * should be removed.
329
+ * @param selector - Which run, when the guide can have more than one open.
330
+ * @returns Promise that resolves once the host has ended the run.
331
+ *
332
+ * @example
333
+ * ```typescript
334
+ * // The appliance this maintenance flow services was deleted.
335
+ * await energyApp.useOnboardingV2().removeOnboardingRun('wallbox-service', {applianceId});
336
+ * ```
337
+ */
338
+ removeOnboardingRun(name: string, selector?: EnyoOnboardingV2RunSelector): Promise<void>;
199
339
  /**
200
340
  * Registers the handler the host calls to resolve dynamic block values
201
341
  * (`ocpp-url`, `device-ip`) while a step is rendered.
@@ -11,16 +11,37 @@ export declare enum EnyoChargeStatus {
11
11
  Failed = "Failed"
12
12
  }
13
13
  /**
14
- * Meter values recorded during a charging session
14
+ * A single sample recorded during a charging session — the charger's meter
15
+ * reading at one instant, plus whatever electrical detail it reported with it.
16
+ *
17
+ * `timestamp` and `valueWh` are the load-bearing pair: every energy total and
18
+ * every cost in a charge is a delta between two samples' `valueWh`, walked in
19
+ * timestamp order (see `calculateChargeCost()`). The rest is detail the charger
20
+ * may or may not report.
21
+ *
22
+ * **Pricing fields are normally filled in by the host, not the app.** Leave
23
+ * {@link pricePerKwh} and {@link chargingCostEuro} unset and the host resolves
24
+ * the tariff for the sample's 15-minute slot and derives the incremental cost
25
+ * itself; set them and your values are kept. Deriving them app-side means
26
+ * reimplementing the tariff lookup, and getting the cent-native unit of
27
+ * `pricePerKwh` wrong there is a silent factor-100 error in the customer's bill.
15
28
  */
16
29
  export interface ChargeMeterValue {
17
30
  /** Timestamp when the value was recorded */
18
31
  timestamp: Date;
19
32
  /** Energy value in Watt hours */
20
33
  valueWh: number;
21
- /** Price per kWh at the time of measurement */
34
+ /**
35
+ * Price per kWh at the time of measurement, in **Euro cents** (ct/kWh) —
36
+ * not Euro. Usually left unset for the host to resolve from the appliance's
37
+ * electricity tariff; see the note on {@link ChargeMeterValue}.
38
+ */
22
39
  pricePerKwh?: number;
23
- /** Charging cost in Euro for this measurement */
40
+ /**
41
+ * Incremental charging cost in **Euro** for this sample — the energy
42
+ * delivered since the previous sample priced at {@link pricePerKwh}, not a
43
+ * running total. Usually left unset for the host to derive.
44
+ */
24
45
  chargingCostEuro?: number;
25
46
  /** Current on phase 1 in Amperes */
26
47
  currentPhase1: number;
@@ -28,6 +49,23 @@ export interface ChargeMeterValue {
28
49
  currentPhase2?: number;
29
50
  /** Current on phase 3 in Amperes */
30
51
  currentPhase3?: number;
52
+ /**
53
+ * Active charging power in Watt at the moment of the sample.
54
+ *
55
+ * Optional because not every charger reports it and it is derivable from
56
+ * the `valueWh` deltas — but only coarsely, at the sampling interval, which
57
+ * is why a charger that does report it should write it here. When omitted,
58
+ * the host keeps whatever power it already recorded for a sample with this
59
+ * timestamp (its own meter-value stream may have seen one) rather than
60
+ * overwriting it with a zero.
61
+ */
62
+ powerW?: number;
63
+ /** Voltage on phase 1 in Volt, when the charger reports it. */
64
+ voltageL1?: number;
65
+ /** Voltage on phase 2 in Volt, when the charger reports it. */
66
+ voltageL2?: number;
67
+ /** Voltage on phase 3 in Volt, when the charger reports it. */
68
+ voltageL3?: number;
31
69
  }
32
70
  /**
33
71
  * Represents a charging session in the enyo system.
@@ -80,6 +118,77 @@ export interface EnyoCharge {
80
118
  /** Target completion time for the charging session as an ISO 8601 timestamp */
81
119
  completeAtIsoTimestamp?: string;
82
120
  }
121
+ /**
122
+ * What is known when a charging session opens — the input to
123
+ * {@link EnergyAppCharge.startCharge}.
124
+ *
125
+ * Everything here is fact at plug-in time. The totals a session is judged by
126
+ * ({@link EnyoCharge.totalEnergyKwh}, {@link EnyoCharge.paidPriceEuroCent}) are
127
+ * absent on purpose: they are the host's to compute when the session ends, from
128
+ * the meter readings and the tariff in force while the energy flowed.
129
+ */
130
+ export interface EnyoStartChargeRequest {
131
+ /** The appliance (charger) running the session. */
132
+ applianceId: string;
133
+ /**
134
+ * The charger's transaction ID for this session (OCPP `transactionId` or
135
+ * the protocol's equivalent).
136
+ *
137
+ * Together with `applianceId` this identifies the session: two chargers may
138
+ * independently issue the same transaction ID, so it is unique per
139
+ * appliance, not globally. It is also the idempotency key —
140
+ * {@link EnergyAppCharge.startCharge} returns the existing session rather
141
+ * than opening a second one when this pair is already active.
142
+ */
143
+ transactionId: string;
144
+ /** When charging started. Defaults to the moment the host handles the call. */
145
+ startTime?: Date;
146
+ /** The charger's meter reading at session start, in Watt hours. */
147
+ meterStartValueWh?: number;
148
+ /** Connector on the charge point the vehicle is plugged into. */
149
+ connectorId?: number;
150
+ /** The charging card that authorized the session, if any. */
151
+ chargingCardId?: string;
152
+ /** The vehicle being charged, if known. */
153
+ vehicleId?: string;
154
+ /** Number of phases charging over. Defaults to 3. */
155
+ numberOfPhases?: number;
156
+ /** Charging mode to apply. Defaults to the appliance's configured default. */
157
+ chargeMode?: EnyoChargeModeEnum;
158
+ /** Target completion time as an ISO 8601 timestamp, for optimized modes. */
159
+ completeAtIsoTimestamp?: string;
160
+ }
161
+ /**
162
+ * How a charging session ended — the input to
163
+ * {@link EnergyAppCharge.stopCharge}.
164
+ *
165
+ * Meter readings, not totals: give the host what the charger reported and it
166
+ * derives the delivered energy and the price. See
167
+ * {@link EnergyAppCharge.stopCharge}.
168
+ */
169
+ export interface EnyoStopChargeRequest {
170
+ /** When charging ended. Defaults to the moment the host handles the call. */
171
+ endTime?: Date;
172
+ /** The charger's meter reading at session end, in Watt hours. */
173
+ meterEndValueWh?: number;
174
+ /**
175
+ * Energy delivered over the session in Watt hours, when the charger reports
176
+ * it directly (OCPP `StopTransaction`).
177
+ *
178
+ * Preferred over the meter delta when present — a charger that meters its
179
+ * own session knows better than a subtraction across two readings that may
180
+ * span a meter reset.
181
+ */
182
+ energyDeliveredWh?: number;
183
+ /**
184
+ * How the session ended. Defaults to {@link EnyoChargeStatus.Completed};
185
+ * pass {@link EnyoChargeStatus.Failed} for a session cut short by a fault.
186
+ *
187
+ * Both are terminal and both fire the stopped listener — a handler that
188
+ * assumes success will mis-report faulted sessions.
189
+ */
190
+ status?: EnyoChargeStatus;
191
+ }
83
192
  /**
84
193
  * Represents a single entry in a charging schedule.
85
194
  * Defines a time-bound current limit for smart charging.
@@ -851,6 +851,35 @@ export interface EnyoOnboardingV2Step {
851
851
  * usually bound at registration/publish time and may be omitted here.
852
852
  */
853
853
  export interface EnyoOnboardingV2Guide {
854
+ /**
855
+ * Stable handle for this guide — the name the app calls it by when it wants
856
+ * to act on it later.
857
+ *
858
+ * A guide is normally never addressed: guides are pulled, the app's answer
859
+ * is the complete set, and a guide is retired by leaving it out. This exists
860
+ * for the cases where an app has to say something *about one specific
861
+ * guide* instead of restating the whole set — retiring it with
862
+ * {@link EnergyAppOnboardingV2.removeOnboardingGuide}, or completing or
863
+ * removing the run walking it
864
+ * ({@link EnergyAppOnboardingV2.completeOnboardingRun},
865
+ * {@link EnergyAppOnboardingV2.removeOnboardingRun}).
866
+ *
867
+ * **Stable once shipped, like a step's `name`.** A run in progress is
868
+ * anchored to it, so renaming a guide between two package versions strands
869
+ * whatever was paused inside it. Choose a kebab-case slug that describes the
870
+ * flow rather than the hardware it currently applies to
871
+ * (`wallbox-ocpp-setup`, not `acme-ac22`), and keep it when the bindings
872
+ * change.
873
+ *
874
+ * Unique within the app's answer — two guides sharing a name cannot be told
875
+ * apart, and {@link validateOnboardingV2GuidesResult} rejects the answer.
876
+ *
877
+ * Optional. Omit it and the host files the guide under a name derived from
878
+ * what it binds to (vendor, models, start variant, and the appliance on a
879
+ * maintenance guide) exactly as before — that keeps working, it just cannot
880
+ * be named by an app that never chose a name.
881
+ */
882
+ name?: string;
854
883
  /** Translated display title (de/en). */
855
884
  title: EnyoOnboardingTranslatedContent[];
856
885
  /** Which start situation this guide covers. */
@@ -903,6 +932,28 @@ export interface EnyoOnboardingV2Guide {
903
932
  * {@link validateOnboardingGuideV2} instead of by the compiler.
904
933
  */
905
934
  applianceId?: string;
935
+ /**
936
+ * Whether the end customer is told about this maintenance run — **only
937
+ * meaningful on** {@link EnyoOnboardingV2StartVariant.Maintenance}, and
938
+ * ignored on every other variant.
939
+ *
940
+ * A maintenance run touches an appliance the customer already lives with:
941
+ * it may take the wallbox offline for a few minutes, change how the
942
+ * inverter behaves, or simply happen while nobody is watching. Set this to
943
+ * `true` when the customer should hear about it — the host sends them a
944
+ * notification for the run — and leave it unset when the work is invisible
945
+ * to them and a message would only be noise.
946
+ *
947
+ * Defaults to `false`: a guide says nothing unless it asks to. The
948
+ * installation variants have no customer to notify — there is no appliance
949
+ * yet, and the installer is standing in front of the device — so a guide
950
+ * that sets this anyway is warned about and the value ignored.
951
+ *
952
+ * Optional in the type because one interface serves all four variants; the
953
+ * variant-dependent meaning is enforced by
954
+ * {@link validateOnboardingGuideV2} instead of by the compiler.
955
+ */
956
+ notifyUser?: boolean;
906
957
  /** Optional vendor binding (catalog id). Usually set at publish time. */
907
958
  vendorId?: string;
908
959
  /** Optional model bindings (catalog ids). Usually set at publish time. */
@@ -9,7 +9,7 @@ exports.getSdkVersion = getSdkVersion;
9
9
  /**
10
10
  * Current version of the enyo Energy App SDK.
11
11
  */
12
- exports.SDK_VERSION = '1.0.0';
12
+ exports.SDK_VERSION = '1.2.0';
13
13
  /**
14
14
  * Gets the current SDK version.
15
15
  * @returns The semantic version string of the SDK