@enyo-energy/energy-app-sdk 0.0.190 → 0.0.191
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/dist/cjs/packages/energy-app-diagnostics.d.cts +5 -0
- package/dist/cjs/types/enyo-flexibility-announcement.d.cts +52 -6
- package/dist/cjs/types/enyo-heatpump-appliance.cjs +15 -1
- package/dist/cjs/types/enyo-heatpump-appliance.d.cts +20 -0
- package/dist/cjs/version.cjs +1 -1
- package/dist/cjs/version.d.cts +1 -1
- package/dist/packages/energy-app-diagnostics.d.ts +5 -0
- package/dist/types/enyo-flexibility-announcement.d.ts +52 -6
- package/dist/types/enyo-heatpump-appliance.d.ts +20 -0
- package/dist/types/enyo-heatpump-appliance.js +14 -0
- package/dist/version.d.ts +1 -1
- package/dist/version.js +1 -1
- package/package.json +1 -1
|
@@ -98,6 +98,7 @@ export interface EnergyAppDiagnostics {
|
|
|
98
98
|
* generatedAtIso: new Date().toISOString(),
|
|
99
99
|
* announced: [
|
|
100
100
|
* {
|
|
101
|
+
* id: 'charger:flexible-kwh',
|
|
101
102
|
* category: EnyoApplianceTypeEnum.Charger,
|
|
102
103
|
* flexibilityAnnouncementType:
|
|
103
104
|
* EnyoFlexibilityAnnouncementTypeEnum.FlexibleKwhTarget,
|
|
@@ -110,6 +111,8 @@ export interface EnergyAppDiagnostics {
|
|
|
110
111
|
* },
|
|
111
112
|
* },
|
|
112
113
|
* {
|
|
114
|
+
* id: 'storage:flexible-discharge',
|
|
115
|
+
* applianceId: 'battery-1',
|
|
113
116
|
* category: EnyoApplianceTypeEnum.Storage,
|
|
114
117
|
* flexibilityAnnouncementType:
|
|
115
118
|
* EnyoFlexibilityAnnouncementTypeEnum.FlexibleDischarge,
|
|
@@ -124,6 +127,7 @@ export interface EnergyAppDiagnostics {
|
|
|
124
127
|
* ],
|
|
125
128
|
* granted: [
|
|
126
129
|
* {
|
|
130
|
+
* announcementId: 'charger:flexible-kwh',
|
|
127
131
|
* category: EnyoApplianceTypeEnum.Charger,
|
|
128
132
|
* flexibilityAnnouncementType:
|
|
129
133
|
* EnyoFlexibilityAnnouncementTypeEnum.FlexibleKwhTarget,
|
|
@@ -134,6 +138,7 @@ export interface EnergyAppDiagnostics {
|
|
|
134
138
|
* reason: 'grid connection point limit',
|
|
135
139
|
* },
|
|
136
140
|
* {
|
|
141
|
+
* announcementId: 'storage:flexible-discharge',
|
|
137
142
|
* category: EnyoApplianceTypeEnum.Storage,
|
|
138
143
|
* flexibilityAnnouncementType:
|
|
139
144
|
* EnyoFlexibilityAnnouncementTypeEnum.FlexibleDischarge,
|
|
@@ -125,11 +125,49 @@ export interface EnyoFlexibilityAnnouncementContext {
|
|
|
125
125
|
heatpumpTargetType?: EnyoFlexibilityHeatpumpTargetTypeEnum;
|
|
126
126
|
/** For air-conditioning announcements: what the flexibility is aimed at. */
|
|
127
127
|
airConditioningTargetType?: EnyoFlexibilityAirConditioningTargetTypeEnum;
|
|
128
|
+
/**
|
|
129
|
+
* For storage announcements: the round-trip cost of cycling the battery, in
|
|
130
|
+
* EUR per kWh. The floor a discharge has to beat to be worth licensing.
|
|
131
|
+
*/
|
|
132
|
+
storageCycleCostEurPerKwh?: number;
|
|
133
|
+
/**
|
|
134
|
+
* For storage announcements: the physical discharge floor, in Watts. Signed —
|
|
135
|
+
* negative means discharge, so this is the most negative power the storage can
|
|
136
|
+
* physically reach.
|
|
137
|
+
*/
|
|
138
|
+
storageMinPowerW?: number;
|
|
139
|
+
/** For storage announcements: the physical charge ceiling, in Watts. */
|
|
140
|
+
storageMaxPowerW?: number;
|
|
141
|
+
/** For storage announcements: usable capacity of the storage, in Wh. */
|
|
142
|
+
storageCapacityWh?: number;
|
|
143
|
+
/**
|
|
144
|
+
* For storage announcements: the discharge power we will actually command, in
|
|
145
|
+
* Watts. May be well inside {@link storageMinPowerW} — today it is `0`, i.e. we
|
|
146
|
+
* license discharge without commanding it.
|
|
147
|
+
*/
|
|
148
|
+
storageCommandableDischargeW?: number;
|
|
149
|
+
/**
|
|
150
|
+
* For storage announcements: whether the storage accepts an explicit
|
|
151
|
+
* `Discharge 0` command, i.e. can be told to hold rather than only being left
|
|
152
|
+
* alone.
|
|
153
|
+
*/
|
|
154
|
+
storageCanHold?: boolean;
|
|
128
155
|
}
|
|
129
156
|
/** Fields shared by every category-scoped flexibility announcement. */
|
|
130
157
|
export interface EnyoCategoryFlexibilityAnnouncementBase {
|
|
158
|
+
/**
|
|
159
|
+
* What this announcement IS, stable across cycles — e.g. `storage:peak-requirement`.
|
|
160
|
+
* A category speaks with several at once and (category, type) does not tell them
|
|
161
|
+
* apart. REQUIRED: a positional identity changes whenever a neighbour appears.
|
|
162
|
+
*/
|
|
163
|
+
id: string;
|
|
131
164
|
/** The appliance category this demand aggregates (e.g. `Charger`). */
|
|
132
165
|
category: EnyoApplianceTypeEnum;
|
|
166
|
+
/**
|
|
167
|
+
* The appliance this announcement speaks for, when a category announces per
|
|
168
|
+
* appliance rather than as one aggregate. Absent = the whole category.
|
|
169
|
+
*/
|
|
170
|
+
applianceId?: string;
|
|
133
171
|
/** Optional extra context for the decision maker; absent for most announcements. */
|
|
134
172
|
context?: EnyoFlexibilityAnnouncementContext;
|
|
135
173
|
}
|
|
@@ -143,6 +181,12 @@ export interface EnyoCategoryRequiredKwhTargetAnnouncement extends EnyoCategoryF
|
|
|
143
181
|
kwh: number;
|
|
144
182
|
/** Power band the delivery may use. */
|
|
145
183
|
power: EnyoFlexibilityPowerBand;
|
|
184
|
+
/**
|
|
185
|
+
* Price ceiling, when the requirement is economic rather than absolute.
|
|
186
|
+
* Present on the wire today; without it every economic requirement looked
|
|
187
|
+
* like a MUST-RUN in diagnostics.
|
|
188
|
+
*/
|
|
189
|
+
priceLimitEuroCent?: number;
|
|
146
190
|
};
|
|
147
191
|
}
|
|
148
192
|
/** Deliver `kwh` flexibly (cost-/PV-optimized), aggregated across the category. */
|
|
@@ -224,10 +268,13 @@ export declare enum EnyoCategoryFlexibilityGrantStatusEnum {
|
|
|
224
268
|
* A grant is deliberately flatter than the announcement it answers: the decision
|
|
225
269
|
* maker replies with one allocation — a window, a power envelope, and (for the
|
|
226
270
|
* energy-target and discharge variants) an amount of energy — regardless of which
|
|
227
|
-
* announcement variant produced it. Pairing is by `
|
|
228
|
-
*
|
|
271
|
+
* announcement variant produced it. Pairing is by `announcementId` — the `id` of
|
|
272
|
+
* the announcement being answered — which stays stable across cycles and tells
|
|
273
|
+
* apart the several announcements one category may speak with at once.
|
|
229
274
|
*/
|
|
230
275
|
export interface EnyoCategoryFlexibilityGrant {
|
|
276
|
+
/** The `id` of the announcement this answers. */
|
|
277
|
+
announcementId: string;
|
|
231
278
|
/** The appliance category this allocation is for (e.g. `Charger`). */
|
|
232
279
|
category: EnyoApplianceTypeEnum;
|
|
233
280
|
/** Which announcement variant this grant answers. */
|
|
@@ -270,14 +317,13 @@ export interface EnyoCategoryFlexibilityDiagnostics {
|
|
|
270
317
|
/** ISO 8601 timestamp when this snapshot was taken. */
|
|
271
318
|
generatedAtIso: string;
|
|
272
319
|
/**
|
|
273
|
-
* The flexibility the managers announced, one entry per
|
|
274
|
-
* (category, announcement variant).
|
|
320
|
+
* The flexibility the managers announced, one entry per announcement `id`.
|
|
275
321
|
*/
|
|
276
322
|
announced: EnyoCategoryFlexibilityAnnouncement[];
|
|
277
323
|
/**
|
|
278
324
|
* What the decision maker granted in answer to `announced`. Every entry SHOULD
|
|
279
|
-
* pair with an `announced` entry by `
|
|
280
|
-
*
|
|
325
|
+
* pair with an `announced` entry by `announcementId`; an announcement with no
|
|
326
|
+
* matching grant means the decision had not been taken
|
|
281
327
|
* yet when the snapshot was produced.
|
|
282
328
|
*/
|
|
283
329
|
granted: EnyoCategoryFlexibilityGrant[];
|
|
@@ -1,12 +1,14 @@
|
|
|
1
1
|
"use strict";
|
|
2
2
|
Object.defineProperty(exports, "__esModule", { value: true });
|
|
3
|
-
exports.EnyoHeatpumpApplianceHeatingCircuitTypeEnum = exports.EnyoHeatpumpApplianceAdditionalDeviceEnum = exports.EnyoHeatpumpApplianceConnectionTypeEnum = exports.EnyoHeatpumpApplianceModeEnum = exports.EnyoHeatpumpApplianceAvailableFeaturesEnum = void 0;
|
|
3
|
+
exports.EnyoHeatpumpApplianceHeatingCircuitTypeEnum = exports.EnyoHeatpumpApplianceHeatingRodUsageEnum = exports.EnyoHeatpumpApplianceAdditionalDeviceEnum = exports.EnyoHeatpumpApplianceConnectionTypeEnum = exports.EnyoHeatpumpApplianceModeEnum = exports.EnyoHeatpumpApplianceAvailableFeaturesEnum = void 0;
|
|
4
4
|
var EnyoHeatpumpApplianceAvailableFeaturesEnum;
|
|
5
5
|
(function (EnyoHeatpumpApplianceAvailableFeaturesEnum) {
|
|
6
6
|
/** If the heatpump is capable of domestic hot water*/
|
|
7
7
|
EnyoHeatpumpApplianceAvailableFeaturesEnum["DomesticHotWater"] = "DomesticHotWater";
|
|
8
8
|
/** If the heatpump has a heating rod*/
|
|
9
9
|
EnyoHeatpumpApplianceAvailableFeaturesEnum["HeatingRod"] = "HeatingRod";
|
|
10
|
+
/** If the heating rod of the heatpump can be actively controlled (steered) by the energy manager */
|
|
11
|
+
EnyoHeatpumpApplianceAvailableFeaturesEnum["HeatingRodControllable"] = "HeatingRodControllable";
|
|
10
12
|
/** If the heatpump supports room overheating via heating circuits */
|
|
11
13
|
EnyoHeatpumpApplianceAvailableFeaturesEnum["RoomOverheating"] = "RoomOverheating";
|
|
12
14
|
/** If the heatpump supports buffer tank overheating */
|
|
@@ -62,6 +64,18 @@ var EnyoHeatpumpApplianceAdditionalDeviceEnum;
|
|
|
62
64
|
/** A solar thermal system is present in the installation */
|
|
63
65
|
EnyoHeatpumpApplianceAdditionalDeviceEnum["SolarThermal"] = "SolarThermal";
|
|
64
66
|
})(EnyoHeatpumpApplianceAdditionalDeviceEnum || (exports.EnyoHeatpumpApplianceAdditionalDeviceEnum = EnyoHeatpumpApplianceAdditionalDeviceEnum = {}));
|
|
67
|
+
/**
|
|
68
|
+
* Describes how the heating rod of a heatpump installation is used.
|
|
69
|
+
* Consumers (UI, energy manager) use this to decide whether the heating rod is
|
|
70
|
+
* the sole heat source or only assists the compressor.
|
|
71
|
+
*/
|
|
72
|
+
var EnyoHeatpumpApplianceHeatingRodUsageEnum;
|
|
73
|
+
(function (EnyoHeatpumpApplianceHeatingRodUsageEnum) {
|
|
74
|
+
/** The heating rod is the only heat source used (no compressor support) */
|
|
75
|
+
EnyoHeatpumpApplianceHeatingRodUsageEnum["OnlyHeatingRot"] = "OnlyHeatingRot";
|
|
76
|
+
/** The heating rod is used in addition to the compressor to further increase the temperature */
|
|
77
|
+
EnyoHeatpumpApplianceHeatingRodUsageEnum["HeatingRodForTemperatureIncrease"] = "HeatingRodForTemperatureIncrease";
|
|
78
|
+
})(EnyoHeatpumpApplianceHeatingRodUsageEnum || (exports.EnyoHeatpumpApplianceHeatingRodUsageEnum = EnyoHeatpumpApplianceHeatingRodUsageEnum = {}));
|
|
65
79
|
/**
|
|
66
80
|
* The type of heat emitter connected to a heating circuit. Influences the
|
|
67
81
|
* flow temperatures the circuit operates at (floor heating typically runs at
|
|
@@ -3,6 +3,8 @@ export declare enum EnyoHeatpumpApplianceAvailableFeaturesEnum {
|
|
|
3
3
|
DomesticHotWater = "DomesticHotWater",
|
|
4
4
|
/** If the heatpump has a heating rod*/
|
|
5
5
|
HeatingRod = "HeatingRod",
|
|
6
|
+
/** If the heating rod of the heatpump can be actively controlled (steered) by the energy manager */
|
|
7
|
+
HeatingRodControllable = "HeatingRodControllable",
|
|
6
8
|
/** If the heatpump supports room overheating via heating circuits */
|
|
7
9
|
RoomOverheating = "RoomOverheating",
|
|
8
10
|
/** If the heatpump supports buffer tank overheating */
|
|
@@ -55,6 +57,17 @@ export declare enum EnyoHeatpumpApplianceAdditionalDeviceEnum {
|
|
|
55
57
|
/** A solar thermal system is present in the installation */
|
|
56
58
|
SolarThermal = "SolarThermal"
|
|
57
59
|
}
|
|
60
|
+
/**
|
|
61
|
+
* Describes how the heating rod of a heatpump installation is used.
|
|
62
|
+
* Consumers (UI, energy manager) use this to decide whether the heating rod is
|
|
63
|
+
* the sole heat source or only assists the compressor.
|
|
64
|
+
*/
|
|
65
|
+
export declare enum EnyoHeatpumpApplianceHeatingRodUsageEnum {
|
|
66
|
+
/** The heating rod is the only heat source used (no compressor support) */
|
|
67
|
+
OnlyHeatingRot = "OnlyHeatingRot",
|
|
68
|
+
/** The heating rod is used in addition to the compressor to further increase the temperature */
|
|
69
|
+
HeatingRodForTemperatureIncrease = "HeatingRodForTemperatureIncrease"
|
|
70
|
+
}
|
|
58
71
|
/**
|
|
59
72
|
* The type of heat emitter connected to a heating circuit. Influences the
|
|
60
73
|
* flow temperatures the circuit operates at (floor heating typically runs at
|
|
@@ -124,4 +137,11 @@ export interface EnyoHeatpumpApplianceMetadata {
|
|
|
124
137
|
* heatpump (e.g. a heating rod or a solar thermal system).
|
|
125
138
|
*/
|
|
126
139
|
additionalDevices?: EnyoHeatpumpApplianceAdditionalDeviceEnum[];
|
|
140
|
+
/**
|
|
141
|
+
* How the heating rod of the installation is used (e.g. as the only heat
|
|
142
|
+
* source or only to further increase the temperature on top of the
|
|
143
|
+
* compressor). Only meaningful if the heatpump has a heating rod
|
|
144
|
+
* (see {@link EnyoHeatpumpApplianceAvailableFeaturesEnum.HeatingRod}).
|
|
145
|
+
*/
|
|
146
|
+
heatingRodUsage?: EnyoHeatpumpApplianceHeatingRodUsageEnum;
|
|
127
147
|
}
|
package/dist/cjs/version.cjs
CHANGED
|
@@ -9,7 +9,7 @@ exports.getSdkVersion = getSdkVersion;
|
|
|
9
9
|
/**
|
|
10
10
|
* Current version of the enyo Energy App SDK.
|
|
11
11
|
*/
|
|
12
|
-
exports.SDK_VERSION = '0.0.
|
|
12
|
+
exports.SDK_VERSION = '0.0.191';
|
|
13
13
|
/**
|
|
14
14
|
* Gets the current SDK version.
|
|
15
15
|
* @returns The semantic version string of the SDK
|
package/dist/cjs/version.d.cts
CHANGED
|
@@ -98,6 +98,7 @@ export interface EnergyAppDiagnostics {
|
|
|
98
98
|
* generatedAtIso: new Date().toISOString(),
|
|
99
99
|
* announced: [
|
|
100
100
|
* {
|
|
101
|
+
* id: 'charger:flexible-kwh',
|
|
101
102
|
* category: EnyoApplianceTypeEnum.Charger,
|
|
102
103
|
* flexibilityAnnouncementType:
|
|
103
104
|
* EnyoFlexibilityAnnouncementTypeEnum.FlexibleKwhTarget,
|
|
@@ -110,6 +111,8 @@ export interface EnergyAppDiagnostics {
|
|
|
110
111
|
* },
|
|
111
112
|
* },
|
|
112
113
|
* {
|
|
114
|
+
* id: 'storage:flexible-discharge',
|
|
115
|
+
* applianceId: 'battery-1',
|
|
113
116
|
* category: EnyoApplianceTypeEnum.Storage,
|
|
114
117
|
* flexibilityAnnouncementType:
|
|
115
118
|
* EnyoFlexibilityAnnouncementTypeEnum.FlexibleDischarge,
|
|
@@ -124,6 +127,7 @@ export interface EnergyAppDiagnostics {
|
|
|
124
127
|
* ],
|
|
125
128
|
* granted: [
|
|
126
129
|
* {
|
|
130
|
+
* announcementId: 'charger:flexible-kwh',
|
|
127
131
|
* category: EnyoApplianceTypeEnum.Charger,
|
|
128
132
|
* flexibilityAnnouncementType:
|
|
129
133
|
* EnyoFlexibilityAnnouncementTypeEnum.FlexibleKwhTarget,
|
|
@@ -134,6 +138,7 @@ export interface EnergyAppDiagnostics {
|
|
|
134
138
|
* reason: 'grid connection point limit',
|
|
135
139
|
* },
|
|
136
140
|
* {
|
|
141
|
+
* announcementId: 'storage:flexible-discharge',
|
|
137
142
|
* category: EnyoApplianceTypeEnum.Storage,
|
|
138
143
|
* flexibilityAnnouncementType:
|
|
139
144
|
* EnyoFlexibilityAnnouncementTypeEnum.FlexibleDischarge,
|
|
@@ -125,11 +125,49 @@ export interface EnyoFlexibilityAnnouncementContext {
|
|
|
125
125
|
heatpumpTargetType?: EnyoFlexibilityHeatpumpTargetTypeEnum;
|
|
126
126
|
/** For air-conditioning announcements: what the flexibility is aimed at. */
|
|
127
127
|
airConditioningTargetType?: EnyoFlexibilityAirConditioningTargetTypeEnum;
|
|
128
|
+
/**
|
|
129
|
+
* For storage announcements: the round-trip cost of cycling the battery, in
|
|
130
|
+
* EUR per kWh. The floor a discharge has to beat to be worth licensing.
|
|
131
|
+
*/
|
|
132
|
+
storageCycleCostEurPerKwh?: number;
|
|
133
|
+
/**
|
|
134
|
+
* For storage announcements: the physical discharge floor, in Watts. Signed —
|
|
135
|
+
* negative means discharge, so this is the most negative power the storage can
|
|
136
|
+
* physically reach.
|
|
137
|
+
*/
|
|
138
|
+
storageMinPowerW?: number;
|
|
139
|
+
/** For storage announcements: the physical charge ceiling, in Watts. */
|
|
140
|
+
storageMaxPowerW?: number;
|
|
141
|
+
/** For storage announcements: usable capacity of the storage, in Wh. */
|
|
142
|
+
storageCapacityWh?: number;
|
|
143
|
+
/**
|
|
144
|
+
* For storage announcements: the discharge power we will actually command, in
|
|
145
|
+
* Watts. May be well inside {@link storageMinPowerW} — today it is `0`, i.e. we
|
|
146
|
+
* license discharge without commanding it.
|
|
147
|
+
*/
|
|
148
|
+
storageCommandableDischargeW?: number;
|
|
149
|
+
/**
|
|
150
|
+
* For storage announcements: whether the storage accepts an explicit
|
|
151
|
+
* `Discharge 0` command, i.e. can be told to hold rather than only being left
|
|
152
|
+
* alone.
|
|
153
|
+
*/
|
|
154
|
+
storageCanHold?: boolean;
|
|
128
155
|
}
|
|
129
156
|
/** Fields shared by every category-scoped flexibility announcement. */
|
|
130
157
|
export interface EnyoCategoryFlexibilityAnnouncementBase {
|
|
158
|
+
/**
|
|
159
|
+
* What this announcement IS, stable across cycles — e.g. `storage:peak-requirement`.
|
|
160
|
+
* A category speaks with several at once and (category, type) does not tell them
|
|
161
|
+
* apart. REQUIRED: a positional identity changes whenever a neighbour appears.
|
|
162
|
+
*/
|
|
163
|
+
id: string;
|
|
131
164
|
/** The appliance category this demand aggregates (e.g. `Charger`). */
|
|
132
165
|
category: EnyoApplianceTypeEnum;
|
|
166
|
+
/**
|
|
167
|
+
* The appliance this announcement speaks for, when a category announces per
|
|
168
|
+
* appliance rather than as one aggregate. Absent = the whole category.
|
|
169
|
+
*/
|
|
170
|
+
applianceId?: string;
|
|
133
171
|
/** Optional extra context for the decision maker; absent for most announcements. */
|
|
134
172
|
context?: EnyoFlexibilityAnnouncementContext;
|
|
135
173
|
}
|
|
@@ -143,6 +181,12 @@ export interface EnyoCategoryRequiredKwhTargetAnnouncement extends EnyoCategoryF
|
|
|
143
181
|
kwh: number;
|
|
144
182
|
/** Power band the delivery may use. */
|
|
145
183
|
power: EnyoFlexibilityPowerBand;
|
|
184
|
+
/**
|
|
185
|
+
* Price ceiling, when the requirement is economic rather than absolute.
|
|
186
|
+
* Present on the wire today; without it every economic requirement looked
|
|
187
|
+
* like a MUST-RUN in diagnostics.
|
|
188
|
+
*/
|
|
189
|
+
priceLimitEuroCent?: number;
|
|
146
190
|
};
|
|
147
191
|
}
|
|
148
192
|
/** Deliver `kwh` flexibly (cost-/PV-optimized), aggregated across the category. */
|
|
@@ -224,10 +268,13 @@ export declare enum EnyoCategoryFlexibilityGrantStatusEnum {
|
|
|
224
268
|
* A grant is deliberately flatter than the announcement it answers: the decision
|
|
225
269
|
* maker replies with one allocation — a window, a power envelope, and (for the
|
|
226
270
|
* energy-target and discharge variants) an amount of energy — regardless of which
|
|
227
|
-
* announcement variant produced it. Pairing is by `
|
|
228
|
-
*
|
|
271
|
+
* announcement variant produced it. Pairing is by `announcementId` — the `id` of
|
|
272
|
+
* the announcement being answered — which stays stable across cycles and tells
|
|
273
|
+
* apart the several announcements one category may speak with at once.
|
|
229
274
|
*/
|
|
230
275
|
export interface EnyoCategoryFlexibilityGrant {
|
|
276
|
+
/** The `id` of the announcement this answers. */
|
|
277
|
+
announcementId: string;
|
|
231
278
|
/** The appliance category this allocation is for (e.g. `Charger`). */
|
|
232
279
|
category: EnyoApplianceTypeEnum;
|
|
233
280
|
/** Which announcement variant this grant answers. */
|
|
@@ -270,14 +317,13 @@ export interface EnyoCategoryFlexibilityDiagnostics {
|
|
|
270
317
|
/** ISO 8601 timestamp when this snapshot was taken. */
|
|
271
318
|
generatedAtIso: string;
|
|
272
319
|
/**
|
|
273
|
-
* The flexibility the managers announced, one entry per
|
|
274
|
-
* (category, announcement variant).
|
|
320
|
+
* The flexibility the managers announced, one entry per announcement `id`.
|
|
275
321
|
*/
|
|
276
322
|
announced: EnyoCategoryFlexibilityAnnouncement[];
|
|
277
323
|
/**
|
|
278
324
|
* What the decision maker granted in answer to `announced`. Every entry SHOULD
|
|
279
|
-
* pair with an `announced` entry by `
|
|
280
|
-
*
|
|
325
|
+
* pair with an `announced` entry by `announcementId`; an announcement with no
|
|
326
|
+
* matching grant means the decision had not been taken
|
|
281
327
|
* yet when the snapshot was produced.
|
|
282
328
|
*/
|
|
283
329
|
granted: EnyoCategoryFlexibilityGrant[];
|
|
@@ -3,6 +3,8 @@ export declare enum EnyoHeatpumpApplianceAvailableFeaturesEnum {
|
|
|
3
3
|
DomesticHotWater = "DomesticHotWater",
|
|
4
4
|
/** If the heatpump has a heating rod*/
|
|
5
5
|
HeatingRod = "HeatingRod",
|
|
6
|
+
/** If the heating rod of the heatpump can be actively controlled (steered) by the energy manager */
|
|
7
|
+
HeatingRodControllable = "HeatingRodControllable",
|
|
6
8
|
/** If the heatpump supports room overheating via heating circuits */
|
|
7
9
|
RoomOverheating = "RoomOverheating",
|
|
8
10
|
/** If the heatpump supports buffer tank overheating */
|
|
@@ -55,6 +57,17 @@ export declare enum EnyoHeatpumpApplianceAdditionalDeviceEnum {
|
|
|
55
57
|
/** A solar thermal system is present in the installation */
|
|
56
58
|
SolarThermal = "SolarThermal"
|
|
57
59
|
}
|
|
60
|
+
/**
|
|
61
|
+
* Describes how the heating rod of a heatpump installation is used.
|
|
62
|
+
* Consumers (UI, energy manager) use this to decide whether the heating rod is
|
|
63
|
+
* the sole heat source or only assists the compressor.
|
|
64
|
+
*/
|
|
65
|
+
export declare enum EnyoHeatpumpApplianceHeatingRodUsageEnum {
|
|
66
|
+
/** The heating rod is the only heat source used (no compressor support) */
|
|
67
|
+
OnlyHeatingRot = "OnlyHeatingRot",
|
|
68
|
+
/** The heating rod is used in addition to the compressor to further increase the temperature */
|
|
69
|
+
HeatingRodForTemperatureIncrease = "HeatingRodForTemperatureIncrease"
|
|
70
|
+
}
|
|
58
71
|
/**
|
|
59
72
|
* The type of heat emitter connected to a heating circuit. Influences the
|
|
60
73
|
* flow temperatures the circuit operates at (floor heating typically runs at
|
|
@@ -124,4 +137,11 @@ export interface EnyoHeatpumpApplianceMetadata {
|
|
|
124
137
|
* heatpump (e.g. a heating rod or a solar thermal system).
|
|
125
138
|
*/
|
|
126
139
|
additionalDevices?: EnyoHeatpumpApplianceAdditionalDeviceEnum[];
|
|
140
|
+
/**
|
|
141
|
+
* How the heating rod of the installation is used (e.g. as the only heat
|
|
142
|
+
* source or only to further increase the temperature on top of the
|
|
143
|
+
* compressor). Only meaningful if the heatpump has a heating rod
|
|
144
|
+
* (see {@link EnyoHeatpumpApplianceAvailableFeaturesEnum.HeatingRod}).
|
|
145
|
+
*/
|
|
146
|
+
heatingRodUsage?: EnyoHeatpumpApplianceHeatingRodUsageEnum;
|
|
127
147
|
}
|
|
@@ -4,6 +4,8 @@ export var EnyoHeatpumpApplianceAvailableFeaturesEnum;
|
|
|
4
4
|
EnyoHeatpumpApplianceAvailableFeaturesEnum["DomesticHotWater"] = "DomesticHotWater";
|
|
5
5
|
/** If the heatpump has a heating rod*/
|
|
6
6
|
EnyoHeatpumpApplianceAvailableFeaturesEnum["HeatingRod"] = "HeatingRod";
|
|
7
|
+
/** If the heating rod of the heatpump can be actively controlled (steered) by the energy manager */
|
|
8
|
+
EnyoHeatpumpApplianceAvailableFeaturesEnum["HeatingRodControllable"] = "HeatingRodControllable";
|
|
7
9
|
/** If the heatpump supports room overheating via heating circuits */
|
|
8
10
|
EnyoHeatpumpApplianceAvailableFeaturesEnum["RoomOverheating"] = "RoomOverheating";
|
|
9
11
|
/** If the heatpump supports buffer tank overheating */
|
|
@@ -59,6 +61,18 @@ export var EnyoHeatpumpApplianceAdditionalDeviceEnum;
|
|
|
59
61
|
/** A solar thermal system is present in the installation */
|
|
60
62
|
EnyoHeatpumpApplianceAdditionalDeviceEnum["SolarThermal"] = "SolarThermal";
|
|
61
63
|
})(EnyoHeatpumpApplianceAdditionalDeviceEnum || (EnyoHeatpumpApplianceAdditionalDeviceEnum = {}));
|
|
64
|
+
/**
|
|
65
|
+
* Describes how the heating rod of a heatpump installation is used.
|
|
66
|
+
* Consumers (UI, energy manager) use this to decide whether the heating rod is
|
|
67
|
+
* the sole heat source or only assists the compressor.
|
|
68
|
+
*/
|
|
69
|
+
export var EnyoHeatpumpApplianceHeatingRodUsageEnum;
|
|
70
|
+
(function (EnyoHeatpumpApplianceHeatingRodUsageEnum) {
|
|
71
|
+
/** The heating rod is the only heat source used (no compressor support) */
|
|
72
|
+
EnyoHeatpumpApplianceHeatingRodUsageEnum["OnlyHeatingRot"] = "OnlyHeatingRot";
|
|
73
|
+
/** The heating rod is used in addition to the compressor to further increase the temperature */
|
|
74
|
+
EnyoHeatpumpApplianceHeatingRodUsageEnum["HeatingRodForTemperatureIncrease"] = "HeatingRodForTemperatureIncrease";
|
|
75
|
+
})(EnyoHeatpumpApplianceHeatingRodUsageEnum || (EnyoHeatpumpApplianceHeatingRodUsageEnum = {}));
|
|
62
76
|
/**
|
|
63
77
|
* The type of heat emitter connected to a heating circuit. Influences the
|
|
64
78
|
* flow temperatures the circuit operates at (floor heating typically runs at
|
package/dist/version.d.ts
CHANGED
package/dist/version.js
CHANGED