@enyo-energy/energy-app-sdk 0.0.189 → 0.0.190

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
@@ -42,4 +42,17 @@ export interface EnyoInverterApplianceMetadata {
42
42
  * `undefined` means "not configured" and should be treated as `false`.
43
43
  */
44
44
  blockFeedInOnNegativePrices?: boolean;
45
+ /**
46
+ * Whether the energy manager may actively steer this inverter (e.g. curtail
47
+ * production). When omitted, consumers fall back to their configured
48
+ * default behaviour — same contract as the SDK's own `controlAllowed`.
49
+ */
50
+ controlAllowed?: boolean;
51
+ /**
52
+ * Peak power of the PV modules attached to this inverter, in Watt-peak, as
53
+ * stated on the Anlagenpass. Distinct from `maxPvProductionW`, which is
54
+ * what the inverter itself can put out on the AC side; together with
55
+ * `moduleGroups` it also gives the power of a single module.
56
+ */
57
+ installedPeakPowerWp?: number;
45
58
  }
@@ -9,7 +9,7 @@ exports.getSdkVersion = getSdkVersion;
9
9
  /**
10
10
  * Current version of the enyo Energy App SDK.
11
11
  */
12
- exports.SDK_VERSION = '0.0.189';
12
+ exports.SDK_VERSION = '0.0.190';
13
13
  /**
14
14
  * Gets the current SDK version.
15
15
  * @returns The semantic version string of the SDK
@@ -5,7 +5,7 @@
5
5
  /**
6
6
  * Current version of the enyo Energy App SDK.
7
7
  */
8
- export declare const SDK_VERSION = "0.0.189";
8
+ export declare const SDK_VERSION = "0.0.190";
9
9
  /**
10
10
  * Gets the current SDK version.
11
11
  * @returns The semantic version string of the SDK
@@ -42,4 +42,17 @@ export interface EnyoInverterApplianceMetadata {
42
42
  * `undefined` means "not configured" and should be treated as `false`.
43
43
  */
44
44
  blockFeedInOnNegativePrices?: boolean;
45
+ /**
46
+ * Whether the energy manager may actively steer this inverter (e.g. curtail
47
+ * production). When omitted, consumers fall back to their configured
48
+ * default behaviour — same contract as the SDK's own `controlAllowed`.
49
+ */
50
+ controlAllowed?: boolean;
51
+ /**
52
+ * Peak power of the PV modules attached to this inverter, in Watt-peak, as
53
+ * stated on the Anlagenpass. Distinct from `maxPvProductionW`, which is
54
+ * what the inverter itself can put out on the AC side; together with
55
+ * `moduleGroups` it also gives the power of a single module.
56
+ */
57
+ installedPeakPowerWp?: number;
45
58
  }
package/dist/version.d.ts CHANGED
@@ -5,7 +5,7 @@
5
5
  /**
6
6
  * Current version of the enyo Energy App SDK.
7
7
  */
8
- export declare const SDK_VERSION = "0.0.189";
8
+ export declare const SDK_VERSION = "0.0.190";
9
9
  /**
10
10
  * Gets the current SDK version.
11
11
  * @returns The semantic version string of the SDK
package/dist/version.js CHANGED
@@ -5,7 +5,7 @@
5
5
  /**
6
6
  * Current version of the enyo Energy App SDK.
7
7
  */
8
- export const SDK_VERSION = '0.0.189';
8
+ export const SDK_VERSION = '0.0.190';
9
9
  /**
10
10
  * Gets the current SDK version.
11
11
  * @returns The semantic version string of the SDK
package/package.json CHANGED
@@ -1,6 +1,6 @@
1
1
  {
2
2
  "name": "@enyo-energy/energy-app-sdk",
3
- "version": "0.0.189",
3
+ "version": "0.0.190",
4
4
  "description": "enyo Energy App SDK",
5
5
  "type": "module",
6
6
  "main": "dist/index.js",