@enyo-energy/energy-app-sdk 0.0.189 → 0.0.190
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
|
@@ -42,4 +42,17 @@ export interface EnyoInverterApplianceMetadata {
|
|
|
42
42
|
* `undefined` means "not configured" and should be treated as `false`.
|
|
43
43
|
*/
|
|
44
44
|
blockFeedInOnNegativePrices?: boolean;
|
|
45
|
+
/**
|
|
46
|
+
* Whether the energy manager may actively steer this inverter (e.g. curtail
|
|
47
|
+
* production). When omitted, consumers fall back to their configured
|
|
48
|
+
* default behaviour — same contract as the SDK's own `controlAllowed`.
|
|
49
|
+
*/
|
|
50
|
+
controlAllowed?: boolean;
|
|
51
|
+
/**
|
|
52
|
+
* Peak power of the PV modules attached to this inverter, in Watt-peak, as
|
|
53
|
+
* stated on the Anlagenpass. Distinct from `maxPvProductionW`, which is
|
|
54
|
+
* what the inverter itself can put out on the AC side; together with
|
|
55
|
+
* `moduleGroups` it also gives the power of a single module.
|
|
56
|
+
*/
|
|
57
|
+
installedPeakPowerWp?: number;
|
|
45
58
|
}
|
package/dist/cjs/version.cjs
CHANGED
|
@@ -9,7 +9,7 @@ exports.getSdkVersion = getSdkVersion;
|
|
|
9
9
|
/**
|
|
10
10
|
* Current version of the enyo Energy App SDK.
|
|
11
11
|
*/
|
|
12
|
-
exports.SDK_VERSION = '0.0.
|
|
12
|
+
exports.SDK_VERSION = '0.0.190';
|
|
13
13
|
/**
|
|
14
14
|
* Gets the current SDK version.
|
|
15
15
|
* @returns The semantic version string of the SDK
|
package/dist/cjs/version.d.cts
CHANGED
|
@@ -42,4 +42,17 @@ export interface EnyoInverterApplianceMetadata {
|
|
|
42
42
|
* `undefined` means "not configured" and should be treated as `false`.
|
|
43
43
|
*/
|
|
44
44
|
blockFeedInOnNegativePrices?: boolean;
|
|
45
|
+
/**
|
|
46
|
+
* Whether the energy manager may actively steer this inverter (e.g. curtail
|
|
47
|
+
* production). When omitted, consumers fall back to their configured
|
|
48
|
+
* default behaviour — same contract as the SDK's own `controlAllowed`.
|
|
49
|
+
*/
|
|
50
|
+
controlAllowed?: boolean;
|
|
51
|
+
/**
|
|
52
|
+
* Peak power of the PV modules attached to this inverter, in Watt-peak, as
|
|
53
|
+
* stated on the Anlagenpass. Distinct from `maxPvProductionW`, which is
|
|
54
|
+
* what the inverter itself can put out on the AC side; together with
|
|
55
|
+
* `moduleGroups` it also gives the power of a single module.
|
|
56
|
+
*/
|
|
57
|
+
installedPeakPowerWp?: number;
|
|
45
58
|
}
|
package/dist/version.d.ts
CHANGED
package/dist/version.js
CHANGED