@energiok/node-red-contrib-pricecontrol-thermal 1.2.2 → 1.2.3

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
package/package.json CHANGED
@@ -1,6 +1,6 @@
1
1
  {
2
2
  "name": "@energiok/node-red-contrib-pricecontrol-thermal",
3
- "version": "1.2.2",
3
+ "version": "1.2.3",
4
4
  "private": false,
5
5
  "publishConfig": {
6
6
  "access": "restricted"
@@ -437,6 +437,41 @@ function calculateCoastTime(indoorTemp, outdoorTemp, comfortMin, heatLossCoeffic
437
437
  * @returns {number} Retention time in minutes
438
438
  */
439
439
  function calculateBoostRetention(outdoorTemp, comfortMax, comfortMin, heatLossCoefficient) {
440
+ // Boost duration should INCREASE in cold weather (building needs more heat)
441
+ // and DECREASE in mild weather (risk of overheating)
442
+ //
443
+ // Logic: In cold weather, we want to store more thermal energy during cheap hours
444
+ // because we'll need it. In mild weather, limit boost to avoid overshooting comfort.
445
+ //
446
+ // Base: 2 hours at 10°C (mild), scaling up to 6 hours at -20°C (very cold)
447
+ const baseBoostMinutes = 120; // 2 hours minimum
448
+ const maxBoostMinutes = 360; // 6 hours maximum
449
+
450
+ // Reference temperatures for scaling
451
+ const mildTemp = 10; // At this temp or above, use base boost
452
+ const coldTemp = -20; // At this temp or below, use max boost
453
+
454
+ if (outdoorTemp >= mildTemp) {
455
+ return baseBoostMinutes;
456
+ }
457
+
458
+ if (outdoorTemp <= coldTemp) {
459
+ return maxBoostMinutes;
460
+ }
461
+
462
+ // Linear interpolation between mild and cold
463
+ const tempRange = mildTemp - coldTemp; // 30 degrees
464
+ const tempBelow = mildTemp - outdoorTemp; // How far below mild
465
+ const boostRange = maxBoostMinutes - baseBoostMinutes; // 240 minutes
466
+
467
+ return baseBoostMinutes + (boostRange * tempBelow) / tempRange;
468
+ }
469
+
470
+ /**
471
+ * Legacy calculation - kept for reference but no longer used
472
+ * Calculates heat retention based on thermal loss (inverse of what we want)
473
+ */
474
+ function calculateBoostRetentionLegacy(outdoorTemp, comfortMax, comfortMin, heatLossCoefficient) {
440
475
  const tempBuffer = comfortMax - comfortMin;
441
476
  const tempDelta = comfortMax - outdoorTemp;
442
477
  const heatLossRate = tempDelta * heatLossCoefficient;
@@ -446,6 +481,10 @@ function calculateBoostRetention(outdoorTemp, comfortMax, comfortMin, heatLossCo
446
481
  return (tempBuffer / heatLossRate) * 60; // Convert hours to minutes
447
482
  }
448
483
 
484
+ // Remove the legacy function from export but keep for backwards compat if called directly
485
+ // eslint-disable-next-line no-unused-vars
486
+ const _legacyBoostRetention = calculateBoostRetentionLegacy;
487
+
449
488
  // ============================================================================
450
489
  // Schedule Generation
451