@digital4better/data 1.3.71 → 1.3.72
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/README.md +46 -235
- package/data/ai/README.md +64 -49
- package/data/cloud/README.md +166 -142
- package/data/cloud/aws-vms.csv +1434 -1434
- package/data/cloud/aws-vms.json +0 -1433
- package/data/cloud/azure-vms.csv +1355 -1355
- package/data/cloud/azure-vms.json +0 -1354
- package/data/cloud/gcp-vms.csv +592 -592
- package/data/cloud/gcp-vms.json +0 -591
- package/data/cloud/oracle-vms.csv +147 -147
- package/data/cloud/oracle-vms.json +0 -146
- package/data/cloud/ovhcloud-vms.csv +80 -80
- package/data/cloud/ovhcloud-vms.json +0 -79
- package/data/cloud/scaleway-vms.csv +217 -217
- package/data/cloud/scaleway-vms.json +0 -216
- package/data/facility/README.md +64 -6
- package/data/transport/README.md +64 -7
- package/llms-full.txt +3 -3
- package/llms.txt +1 -1
- package/package.json +2 -2
package/data/cloud/README.md
CHANGED
|
@@ -1,189 +1,213 @@
|
|
|
1
|
-
# Cloud Reference
|
|
1
|
+
# Cloud Reference Data
|
|
2
2
|
|
|
3
|
-
|
|
3
|
+
Cloud regions, virtual machines, modeled hosts, CPUs and accelerators for AWS, Azure, GCP, Oracle, OVHcloud and Scaleway. Historical offers are retained; an entry does not guarantee current availability.
|
|
4
4
|
|
|
5
|
-
##
|
|
5
|
+
## Files
|
|
6
6
|
|
|
7
|
-
|
|
7
|
+
Each provider has separate region, VM and host catalogs, available as JSON and flat CSV.
|
|
8
8
|
|
|
9
|
-
| Provider |
|
|
10
|
-
| --- |
|
|
11
|
-
| AWS |
|
|
12
|
-
| Azure |
|
|
13
|
-
| GCP |
|
|
14
|
-
| Oracle |
|
|
15
|
-
| OVHcloud |
|
|
16
|
-
| Scaleway |
|
|
9
|
+
| Provider | Regions | VMs | Hosts |
|
|
10
|
+
| --- | --- | --- | --- |
|
|
11
|
+
| AWS | [JSON](./aws-regions.json) · [CSV](./aws-regions.csv) | [JSON](./aws-vms.json) · [CSV](./aws-vms.csv) | [JSON](./aws-hosts.json) · [CSV](./aws-hosts.csv) |
|
|
12
|
+
| Azure | [JSON](./azure-regions.json) · [CSV](./azure-regions.csv) | [JSON](./azure-vms.json) · [CSV](./azure-vms.csv) | [JSON](./azure-hosts.json) · [CSV](./azure-hosts.csv) |
|
|
13
|
+
| GCP | [JSON](./gcp-regions.json) · [CSV](./gcp-regions.csv) | [JSON](./gcp-vms.json) · [CSV](./gcp-vms.csv) | [JSON](./gcp-hosts.json) · [CSV](./gcp-hosts.csv) |
|
|
14
|
+
| Oracle | [JSON](./oracle-regions.json) · [CSV](./oracle-regions.csv) | [JSON](./oracle-vms.json) · [CSV](./oracle-vms.csv) | [JSON](./oracle-hosts.json) · [CSV](./oracle-hosts.csv) |
|
|
15
|
+
| OVHcloud | [JSON](./ovhcloud-regions.json) · [CSV](./ovhcloud-regions.csv) | [JSON](./ovhcloud-vms.json) · [CSV](./ovhcloud-vms.csv) | [JSON](./ovhcloud-hosts.json) · [CSV](./ovhcloud-hosts.csv) |
|
|
16
|
+
| Scaleway | [JSON](./scaleway-regions.json) · [CSV](./scaleway-regions.csv) | [JSON](./scaleway-vms.json) · [CSV](./scaleway-vms.csv) | [JSON](./scaleway-hosts.json) · [CSV](./scaleway-hosts.csv) |
|
|
17
17
|
|
|
18
|
-
|
|
18
|
+
Shared hardware references: CPUs ([JSON](./cpus.json), [CSV](./cpus.csv)) and accelerators ([JSON](./accelerators.json), [CSV](./accelerators.csv)).
|
|
19
19
|
|
|
20
|
-
|
|
21
|
-
| --- | ---: | ---: | --- |
|
|
22
|
-
| AWS `d2.8xlarge` | 36 | 244 GiB | [EC2 storage specifications](https://docs.aws.amazon.com/ec2/latest/instancetypes/so.html) |
|
|
23
|
-
| OVHcloud `a10-45` | 45 | 42 GB | [Public Cloud prices](https://www.ovhcloud.com/en/public-cloud/prices/) |
|
|
24
|
-
| OVHcloud `a10-90` | 90 | 85 GB | [Public Cloud prices](https://www.ovhcloud.com/en/public-cloud/prices/) |
|
|
25
|
-
| OVHcloud `a10-180` | 180 | 170 GB | [Public Cloud prices](https://www.ovhcloud.com/en/public-cloud/prices/) |
|
|
20
|
+
## File Structure and Units
|
|
26
21
|
|
|
27
|
-
|
|
22
|
+
Every JSON file contains an array of objects; its CSV counterpart has one row per object. Optional fields may be absent or empty. Some historical numeric values are decimal strings: preserve their value when parsing. Hardware zeros can be legacy placeholders rather than verified measurements.
|
|
28
23
|
|
|
29
|
-
|
|
30
|
-
|
|
31
|
-
|
|
32
|
-
|
|
33
|
-
|
|
34
|
-
|
|
35
|
-
|
|
24
|
+
<details>
|
|
25
|
+
<summary>Regions: identifiers, locations and environmental indicators</summary>
|
|
26
|
+
|
|
27
|
+
| Field | Type / unit | Meaning |
|
|
28
|
+
| --- | --- | --- |
|
|
29
|
+
| `id`, `name`, `provider` | Text | Region identifier, display name and provider. |
|
|
30
|
+
| `location` | Text | Locality, not a datacenter address. |
|
|
31
|
+
| `country`, `subdivision` | Text codes | Geographic identifiers; country codes generally use lowercase ISO alpha-2. |
|
|
32
|
+
| `lat`, `lon` | Decimal degrees | Approximate latitude and longitude. |
|
|
33
|
+
| `pue` | Dimensionless ratio | Facility energy divided by IT energy. |
|
|
34
|
+
| `wue` | L/kWh | Water usage per IT energy; check the source boundary. |
|
|
35
|
+
| `ref` | Fraction, 0 to 1 | Renewable-energy reference or documented CFE proxy. |
|
|
36
|
+
| `aliases` | String array | Alternative region identifiers (JSON-only). |
|
|
37
|
+
| `partition` | Text | Provider partition, when specified (JSON-only). |
|
|
38
|
+
| `sources`, `notes` | URL array / text | Evidence and interpretation limits (JSON-only). |
|
|
36
39
|
|
|
37
|
-
|
|
40
|
+
</details>
|
|
38
41
|
|
|
39
|
-
|
|
42
|
+
<details>
|
|
43
|
+
<summary>VMs: capacity and allocated manufacturing impact</summary>
|
|
40
44
|
|
|
41
|
-
|
|
|
45
|
+
| Field | Type / unit | Meaning |
|
|
42
46
|
| --- | --- | --- |
|
|
43
|
-
|
|
|
44
|
-
|
|
|
45
|
-
|
|
|
46
|
-
|
|
|
47
|
-
|
|
|
48
|
-
|
|
|
47
|
+
| `id`, `name`, `family`, `category` | Text | Identifier, offer name, family and usage category. |
|
|
48
|
+
| `vcpus` | Count | Virtual CPUs, not necessarily physical cores. |
|
|
49
|
+
| `memory` | GB or GiB | Instance RAM in the source convention; see Capacity Units below. |
|
|
50
|
+
| `ssd`, `hdd` | GB or GiB | Included local storage capacity, not drive count. |
|
|
51
|
+
| `cpu` | ID or array of IDs | Alternative CPU references; CSV joins arrays with commas. |
|
|
52
|
+
| `accelerator` | ID | Reference in `accelerators.json`. |
|
|
53
|
+
| `accelerators` | Count, possibly fractional | Allocated accelerator units; slices need not be whole boards. |
|
|
54
|
+
| `embodied_allocated` | tCO2e | Manufacturing impact allocated to this instance before time amortization. |
|
|
55
|
+
| `embodied` | tCO2e | Deprecated compatibility value; historical allocation scope varies. |
|
|
56
|
+
| `host` | ID | Profile in the same provider's host catalog. |
|
|
57
|
+
| `host_instances` | Positive integer | Maximum modeled number of identical instances per host. |
|
|
58
|
+
| `virtual` | Boolean | `false` for bare metal (JSON-only). |
|
|
59
|
+
| `provider`, `shape` | Text | Provider or original shape, when specified (JSON-only). |
|
|
60
|
+
| `ocpus` | Oracle OCPU count | Provider allocation unit; conversion to vCPUs depends on platform (JSON-only). |
|
|
61
|
+
| `flex` | Boolean | A selected configuration of a flexible shape (JSON-only). |
|
|
49
62
|
|
|
50
|
-
|
|
63
|
+
</details>
|
|
51
64
|
|
|
52
|
-
|
|
65
|
+
<details>
|
|
66
|
+
<summary>Hosts: modeled physical capacity and manufacturing impact</summary>
|
|
53
67
|
|
|
54
|
-
|
|
68
|
+
| Field | Type / unit | Meaning |
|
|
69
|
+
| --- | --- | --- |
|
|
70
|
+
| `id`, `name`, `provider` | Text | Host profile identifier, label and provider. |
|
|
71
|
+
| `basis`, `method` | Text codes | Profile origin and calculation version. |
|
|
72
|
+
| `vcpus` | Count | Modeled allocatable vCPU capacity. |
|
|
73
|
+
| `memory` | GB or GiB | Modeled host RAM, retaining the source convention. |
|
|
74
|
+
| `sockets` | Integer count | Modeled physical CPU sockets. |
|
|
75
|
+
| `cpu` | Array of IDs | Alternative CPU references; CSV joins them with commas. |
|
|
76
|
+
| `ssd_count`, `hdd_count` | Integer counts | Modeled physical drives. |
|
|
77
|
+
| `ssd_capacity`, `hdd_capacity` | GB or GiB | Known local storage capacities used as allocation limits. |
|
|
78
|
+
| `accelerator`, `accelerators` | ID / integer count | Accelerator reference and modeled board count. |
|
|
79
|
+
| `accelerator_memory` | GB per board | Memory used by the manufacturing model. |
|
|
80
|
+
| `embodied` | tCO2e | Whole-host manufacturing impact; this field is not deprecated on hosts. |
|
|
81
|
+
| `sources`, `assumptions` | URL array / code array | Evidence and modeling choices; CSV uses ` | ` between items. |
|
|
55
82
|
|
|
56
|
-
|
|
83
|
+
</details>
|
|
57
84
|
|
|
58
|
-
|
|
85
|
+
<details>
|
|
86
|
+
<summary>CPUs and accelerators: shared hardware references</summary>
|
|
59
87
|
|
|
60
|
-
|
|
88
|
+
| Field | Type / unit | Meaning |
|
|
89
|
+
| --- | --- | --- |
|
|
90
|
+
| `id`, `manufacturer`, `serie`, `model` | Identifiers / labels | Component identity; some historical model labels are numeric. |
|
|
91
|
+
| `architecture`, `platform` | Text | Architecture (CPU) and platform/generation. |
|
|
92
|
+
| `type` | Text | Accelerator class, such as GPU, ASIC or FPGA. |
|
|
93
|
+
| `cores`, `threads` | Counts | Hardware cores and CPU threads; accelerator cores are not CPU-equivalent. |
|
|
94
|
+
| `memory` | GB | Accelerator memory; verify whether the reference describes a chip or a multi-chip board. |
|
|
95
|
+
| `tdp` | W | Thermal design envelope, not measured workload power. |
|
|
96
|
+
| `process` | nm convention | Reported process node, not a measured physical feature size. |
|
|
97
|
+
| `die` | mm2 | Reported die area; legacy chiplet/package boundaries can differ. |
|
|
98
|
+
| `transistors` | Millions | Reported transistor count. |
|
|
99
|
+
| `smp` | Socket count | CPU maximum socket support, not installed host sockets. |
|
|
61
100
|
|
|
62
|
-
|
|
63
|
-
|
|
64
|
-
|
|
65
|
-
| `cpu-proxy` | Instance CPU references are model inputs, not verified host inventory. |
|
|
66
|
-
| `max-impact` | Highest allocated result among compatible modeled candidates, not a proven upper bound. |
|
|
67
|
-
| `published-sockets` | Socket count from a compatible dedicated-host family. |
|
|
68
|
-
| `inferred-sockets` | Sockets inferred from CPU capacity, with architecture defaults when unknown. |
|
|
69
|
-
| `baremetal-proxy` | Bare-metal resources proxy the host; placement and reserved capacity remain unknown. |
|
|
70
|
-
| `family-proxy` | Compatible family configuration proxies the host; actual deployment is unverified. |
|
|
71
|
-
| `largest-size-vcpu` | Largest matching SKU supplies the vCPU envelope, without another SMT multiplier. |
|
|
72
|
-
| `catalog-proxy` | Largest matching SKU proxies the host, using exposed RAM and inferred components. |
|
|
73
|
-
| `dedicated-host-proxy` | Published dedicated-host capacity proxies ordinary VM hosting. |
|
|
74
|
-
| `sole-tenant-proxy` | Published sole-tenant capacity and sockets proxy ordinary VM hosting. |
|
|
75
|
-
| `dedicated-fallback` | Unknown mapping: dedicated-equivalent envelope allocated at 100%. |
|
|
76
|
-
| `desktop-fallback` | Rack-equivalent desktop proxy, not a product LCA or proven upper bound. |
|
|
77
|
-
| `one-ssd` | One physical local SSD assumed; guest partitions are not physical drives. |
|
|
78
|
-
| `one-hdd` | One physical local HDD assumed; actual count is unknown. |
|
|
79
|
-
| `storage-proxy` | Physical drive count is modeled, not the guest partition count. |
|
|
80
|
-
| `non-gpu-proxy` | ASIC/FPGA uses GPU board/memory coefficients and board-equivalent quantities. |
|
|
81
|
-
| `accelerator-memory-default` | Unknown accelerator memory uses a 16 GB placeholder. |
|
|
82
|
-
| `gpu-host-proxy` | Full GPU-family configuration proxies the host; numeric assumptions are in its fields. |
|
|
83
|
-
| `hbm-ram-proxy` | HBM uses the ordinary RAM coefficient. |
|
|
84
|
-
| `installed-ram-proxy` | Installed RAM is modeled from the family envelope, not guest-available RAM. |
|
|
85
|
-
| `storage-pools` | Diskless and local-storage variants use separate modeled host pools. |
|
|
86
|
-
| `cpu-generation-proxy` | Host envelope is specific to the modeled CPU generation. |
|
|
87
|
-
| `interconnect-excluded` | Additional interconnect hardware is excluded. |
|
|
88
|
-
| `installed-vram` | Installed GPU memory replaces guest-usable memory. |
|
|
89
|
-
| `remote-storage-excluded` | Remote block storage is excluded from host manufacturing impact. |
|
|
101
|
+
</details>
|
|
102
|
+
|
|
103
|
+
## Using the Data
|
|
90
104
|
|
|
91
|
-
`
|
|
105
|
+
- Join a VM's `host` to an `id` in the same provider's host catalog. CPU and accelerator IDs refer to the shared hardware catalogs.
|
|
106
|
+
- **Use VM `embodied_allocated` for manufacturing impact**, in tCO2e before lifetime/time amortization. Host `embodied` describes the whole modeled host.
|
|
107
|
+
- **VM `embodied` is deprecated.** Previously populated values are retained; previously missing values use the allocated impact. Its historical scope is inconsistent: do not assume it always describes a host or a VM.
|
|
108
|
+
- Missing properties and empty CSV cells mean unavailable data, not zero. Regions without coordinates are usable in downloads but not plotted on the map.
|
|
109
|
+
- CPU arrays list alternative processors, not socket counts. Fractional accelerator quantities describe VM allocations; host counts describe physical board equivalents. Bare metal uses `virtual: false`.
|
|
110
|
+
- `ssd` and `hdd` describe included local storage, not optional network disks. Host `sources` and `assumptions` arrays are joined with ` | ` in CSV.
|
|
92
111
|
|
|
93
|
-
###
|
|
112
|
+
### Capacity Units
|
|
94
113
|
|
|
95
|
-
|
|
114
|
+
Capacity numbers retain their source convention: **GB and GiB are not interchangeable**. The following conventions apply to reviewed specifications, not every historical entry.
|
|
115
|
+
|
|
116
|
+
| Provider | RAM | Local storage |
|
|
117
|
+
| --- | --- | --- |
|
|
118
|
+
| AWS | GiB | GB |
|
|
119
|
+
| Azure | Mostly GiB; some series publish GB | GB or GiB depending on series |
|
|
120
|
+
| GCP | GB | GiB |
|
|
121
|
+
| Oracle | GB | GB |
|
|
122
|
+
| OVHcloud | GB | GB |
|
|
123
|
+
| Scaleway | GiB | Check the individual source |
|
|
96
124
|
|
|
97
|
-
|
|
125
|
+
Azure GB RAM exceptions include Dnsv6, Dnlsv6, Ensv6, HBv5, Esv7, Ebsv6, Ebdsv6, Ecasv6 and Ecadsv6. Local storage is GB for Lsv4, Lasv4 and Lasv5/Laosv5; GiB for Ddsv7, Dldsv7, Daldsv7, Dcadsv6, Famdsv7 and Faldsv7. TB/TiB totals are reduced to GB/GiB respectively.
|
|
98
126
|
|
|
99
|
-
|
|
127
|
+
Region `pue` is a ratio, `wue` is L/kWh and `ref` is a fraction. Reporting boundaries differ: Google's CFE fraction is not interchangeable with renewable-energy matching. AWS `ref = 0` and Oracle `wue = 0` are dataset conventions, not verified absence of renewable energy or water use. See the [full reference](https://digital4better.github.io/data/llms-full.txt) for provider-specific rules.
|
|
100
128
|
|
|
101
|
-
|
|
129
|
+
## Methodology
|
|
102
130
|
|
|
103
|
-
|
|
131
|
+
The D4B method `d4b-host-v1` estimates host manufacturing impact from its modeled components:
|
|
104
132
|
|
|
105
|
-
|
|
133
|
+
```text
|
|
134
|
+
host kgCO2e = 1000
|
|
135
|
+
+ (RAM - 16) × 1.3869
|
|
136
|
+
+ (sockets - 1) × 100
|
|
137
|
+
+ SSD count × 100
|
|
138
|
+
+ HDD count × 50
|
|
139
|
+
+ accelerator count × (150 + max(0, accelerator memory - 16) × 1.3869)
|
|
106
140
|
|
|
107
|
-
|
|
141
|
+
embodied_allocated = host.embodied / host_instances
|
|
142
|
+
```
|
|
108
143
|
|
|
109
|
-
|
|
144
|
+
Host RAM is at least 16 GB; the base already includes those 16 GB and one socket. Divide kgCO2e by 1000 for tCO2e. Accelerator memory is per modeled board. The VRAM extension and its application to ASIC/FPGA are D4B approximations; unknown accelerator memory uses a documented 16 GB placeholder.
|
|
110
145
|
|
|
111
|
-
|
|
146
|
+
`host_instances` is the maximum modeled number of **identical** VMs fitting the host, constrained by CPU, RAM, accelerators, known local storage and documented placement limits. The whole host impact, including unused capacity, is divided among those instances. Bare metal and dedicated-equivalent fallbacks use one. Do not allocate the host share a second time or treat this count as observed occupancy.
|
|
112
147
|
|
|
113
|
-
|
|
148
|
+
Among compatible modeled hosts, the method selects the highest per-instance impact. This is a conservative policy, not a proven physical upper bound.
|
|
114
149
|
|
|
115
|
-
|
|
116
|
-
| --- | --- | --- |
|
|
117
|
-
| AWS P6e-GB200 | 4 GPUs rather than 36; local SSD capacity is 3 x 7500 GB rather than zero | [EC2 accelerated instances](https://docs.aws.amazon.com/ec2/latest/instancetypes/ac.html) |
|
|
118
|
-
| Azure M8ms / M16ms | RAM 218.75 / 437.5 GiB, without integer rounding | [M series](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/memory-optimized/m-series) |
|
|
119
|
-
| Azure Mv3 high memory | M416ds/s_6 RAM 5696 GiB; M832ds_12 and M832ids_16 RAM 11400 / 15200 GiB (previously reversed) | [Mdsv3](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/memory-optimized/mdsv3-hm-series), [Msv3](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/memory-optimized/msv3-hm-series) |
|
|
120
|
-
| Azure NCasT4_v3 | EPYC 7V12 rather than 9V74; NC64 RAM 440 GiB; local SSD capacity follows each official size | [NCasT4_v3](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/gpu-accelerated/ncast4v3-series) |
|
|
121
|
-
| Azure NDm A100 / ND MI300X | RAM 1900 / 1850 GiB; A100 local SSD 6400 GiB | [NDm A100](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/gpu-accelerated/ndma100v4-series), [ND MI300X](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/gpu-accelerated/ndmi300xv5-series) |
|
|
122
|
-
| Azure NP | RAM 168 / 336 / 672 GiB and local SSD 736 / 1474 / 2948 GiB | [NP series](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/fpga-accelerated/np-series) |
|
|
123
|
-
| Azure NV | NV6 / NV12 / NV24 allocate 0.5 / 1 / 2 of the catalog's 16 GB dual-GPU M60 boards | [NV series](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/gpu-accelerated/nv-series) |
|
|
124
|
-
| GCP X4 | Xeon Platinum 8490H rather than 8477C | [CPU platforms](https://docs.cloud.google.com/compute/docs/cpu-platforms?hl=en) |
|
|
150
|
+
**Example:** a modeled Azure Dsv6-Type1 host has an impact of 2.4979952 tCO2e. Microsoft's [placement table](https://learn.microsoft.com/en-us/azure/virtual-machines/dedicated-hosts/general-purpose-skus#dsv6) allows 32 D2s_v6 instances, giving 0.07806235 tCO2e per instance. The profile assumes two sockets; the table does not independently verify them.
|
|
125
151
|
|
|
126
|
-
|
|
152
|
+
### Assumption Codes
|
|
127
153
|
|
|
128
|
-
|
|
154
|
+
`basis` describes the profile's origin; `method` identifies the calculation version. `assumptions` contains short codes, while numeric choices remain in the host fields and evidence URLs in `sources`.
|
|
129
155
|
|
|
130
|
-
|
|
156
|
+
<details>
|
|
157
|
+
<summary>Assumption code glossary</summary>
|
|
131
158
|
|
|
132
|
-
|
|
|
159
|
+
| Code | Meaning |
|
|
133
160
|
| --- | --- |
|
|
134
|
-
|
|
|
135
|
-
|
|
|
136
|
-
|
|
|
137
|
-
|
|
|
138
|
-
|
|
|
139
|
-
|
|
|
140
|
-
|
|
|
141
|
-
|
|
|
142
|
-
|
|
|
143
|
-
|
|
|
144
|
-
|
|
|
145
|
-
|
|
|
146
|
-
|
|
147
|
-
|
|
148
|
-
|
|
149
|
-
|
|
150
|
-
|
|
151
|
-
|
|
152
|
-
|
|
153
|
-
|
|
|
154
|
-
|
|
|
155
|
-
|
|
|
156
|
-
|
|
|
157
|
-
|
|
|
158
|
-
|
|
|
159
|
-
|
|
|
160
|
-
| Scaleway | GiB | No local-storage quantities added |
|
|
161
|
+
| `historical-host` | Historical source configuration, not inferred from an old impact. |
|
|
162
|
+
| `cpu-proxy` | Instance CPU reference used as a host proxy. |
|
|
163
|
+
| `max-impact` | Highest allocated result among compatible modeled candidates. |
|
|
164
|
+
| `published-sockets` | Socket count from a compatible dedicated-host family. |
|
|
165
|
+
| `inferred-sockets` | Sockets inferred from CPU capacity or architecture defaults. |
|
|
166
|
+
| `baremetal-proxy` | Bare-metal resources proxy the physical host. |
|
|
167
|
+
| `family-proxy` | Compatible family configuration proxies the host. |
|
|
168
|
+
| `largest-size-vcpu` | Largest matching SKU supplies vCPU capacity, without another SMT multiplier. |
|
|
169
|
+
| `catalog-proxy` | Largest matching SKU supplies the modeled host configuration. |
|
|
170
|
+
| `dedicated-host-proxy` | Dedicated-host capacity proxies ordinary VM hosting. |
|
|
171
|
+
| `sole-tenant-proxy` | Sole-tenant capacity and sockets proxy ordinary VM hosting. |
|
|
172
|
+
| `dedicated-fallback` | Unknown mapping: dedicated-equivalent envelope allocated at 100%. |
|
|
173
|
+
| `desktop-fallback` | Desktop uses a rack-equivalent base, not a product LCA. |
|
|
174
|
+
| `one-ssd` | One physical local SSD assumed. |
|
|
175
|
+
| `one-hdd` | One physical local HDD assumed. |
|
|
176
|
+
| `storage-proxy` | Physical drive count is modeled, not a count of guest partitions. |
|
|
177
|
+
| `non-gpu-proxy` | ASIC/FPGA uses the GPU board/memory coefficients. |
|
|
178
|
+
| `accelerator-memory-default` | Unknown accelerator memory uses 16 GB. |
|
|
179
|
+
| `gpu-host-proxy` | Full GPU-family configuration proxies the host. |
|
|
180
|
+
| `hbm-ram-proxy` | HBM uses the ordinary RAM coefficient. |
|
|
181
|
+
| `installed-ram-proxy` | Installed RAM is modeled rather than copied from guest-available RAM. |
|
|
182
|
+
| `storage-pools` | Diskless and local-storage variants use separate host pools. |
|
|
183
|
+
| `cpu-generation-proxy` | Host envelope is specific to the modeled CPU generation. |
|
|
184
|
+
| `interconnect-excluded` | Additional interconnect hardware is excluded. |
|
|
185
|
+
| `installed-vram` | Installed GPU memory is used instead of guest-usable memory. |
|
|
186
|
+
| `remote-storage-excluded` | Remote block storage is excluded. |
|
|
161
187
|
|
|
162
|
-
|
|
188
|
+
</details>
|
|
189
|
+
|
|
190
|
+
## Sources and Attribution
|
|
163
191
|
|
|
164
|
-
| Provider |
|
|
192
|
+
| Provider | Regions | Machines |
|
|
165
193
|
| --- | --- | --- |
|
|
166
|
-
| AWS | [
|
|
167
|
-
| Azure | [Region
|
|
168
|
-
| GCP | [Regions and zones](https://docs.cloud.google.com/compute/docs/regions-zones
|
|
194
|
+
| AWS | [Region catalog](https://docs.aws.amazon.com/global-infrastructure/latest/regions/aws-regions.html) | [EC2 specifications](https://docs.aws.amazon.com/ec2/latest/instancetypes/instance-types.html) |
|
|
195
|
+
| Azure | [Region catalog](https://learn.microsoft.com/en-us/azure/reliability/regions-list) | [VM sizes](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/overview) |
|
|
196
|
+
| GCP | [Regions and zones](https://docs.cloud.google.com/compute/docs/regions-zones) | [Machine families](https://docs.cloud.google.com/compute/docs/machine-resource), [CPU platforms](https://docs.cloud.google.com/compute/docs/cpu-platforms) |
|
|
169
197
|
| Oracle | [Regions](https://docs.oracle.com/en-us/iaas/Content/General/Concepts/regions.htm) | [Compute shapes](https://docs.oracle.com/en-us/iaas/Content/Compute/References/computeshapes.htm) |
|
|
170
|
-
| OVHcloud | [Public Cloud availability](https://www.ovhcloud.com/en/public-cloud/regions-availability/) | [
|
|
171
|
-
| Scaleway | [Region
|
|
198
|
+
| OVHcloud | [Public Cloud availability](https://www.ovhcloud.com/en/public-cloud/regions-availability/) | [Prices and specifications](https://www.ovhcloud.com/en/public-cloud/prices/) |
|
|
199
|
+
| Scaleway | [Region identifiers](https://www.scaleway.com/en/developers/cli/config) | [Instance datasheet](https://www.scaleway.com/en/docs/instances/reference-content/instances-datasheet/) |
|
|
172
200
|
|
|
173
|
-
|
|
174
|
-
<summary>Detailed specification sources used for this refresh</summary>
|
|
201
|
+
Hardware references also use manufacturer specifications and, where explicitly identified, observed guest CPU models from [Spare Cores](https://sparecores.com/), [Vantage](https://instances.vantage.sh/) and [Cloud Mercato](https://pcr.cloud-mercato.com/). OVHcloud T1/T2 guest CPU observations are not provider-wide guarantees.
|
|
175
202
|
|
|
176
|
-
|
|
177
|
-
- **azure**: [dcedsv6-series](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/general-purpose/dcedsv6-series), [dnsv6-series](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/memory-optimized/dnsv6-series), [dnlsv6-series](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/memory-optimized/dnlsv6-series), [ensv6-series](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/memory-optimized/ensv6-series), [laosv5-series](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/storage-optimized/laosv5-series), [lasv5-series](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/storage-optimized/lasv5-series), [lsv4-series](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/storage-optimized/lsv4-series), [lasv4-series](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/storage-optimized/lasv4-series), [laosv4-series](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/storage-optimized/laosv4-series), [nc-rtxpro6000-bse-v6-series](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/gpu-accelerated/nc-rtxpro6000-bse-v6-series), [nd-gb300-v6-series](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/gpu-accelerated/nd-gb300-v6-series), [nd-gb200-v6-series](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/gpu-accelerated/nd-gb200-v6-series), [hbv5-series](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/high-performance-compute/hbv5-series), [dsv7-series](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/general-purpose/dsv7-series), [ddsv7-series](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/general-purpose/ddsv7-series), [dlsv7-series](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/general-purpose/dlsv7-series), [dldsv7-series](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/general-purpose/dldsv7-series), [dalsv7-series](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/general-purpose/dalsv7-series), [daldsv7-series](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/general-purpose/daldsv7-series), [dcasv6-series](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/general-purpose/dcasv6-series), [dcadsv6-series](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/general-purpose/dcadsv6-series), [dcesv6-series](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/general-purpose/dcesv6-series), [famsv7-series](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/compute-optimized/famsv7-series), [famdsv7-series](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/compute-optimized/famdsv7-series), [falsv7-series](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/compute-optimized/falsv7-series), [faldsv7-series](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/compute-optimized/faldsv7-series), [esv7-series](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/memory-optimized/esv7-series), [edsv7-series](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/memory-optimized/edsv7-series), [ebsv6-series](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/memory-optimized/ebsv6-series), [ebdsv6-series](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/memory-optimized/ebdsv6-series), [ecasv6-series](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/memory-optimized/ecasv6-series), [ecadsv6-series](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/memory-optimized/ecadsv6-series), [msv3-mm-series](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/memory-optimized/msv3-mm-series), [mdsv3-mm-series](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/memory-optimized/mdsv3-mm-series), [msv3-hm-series](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/memory-optimized/msv3-hm-series), [mdsv3-hm-series](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/memory-optimized/mdsv3-hm-series), [mdsv3-vhm-series](https://learn.microsoft.com/en-us/azure/virtual-machines/sizes/memory-optimized/mdsv3-vhm-series), [regions](https://learn.microsoft.com/en-us/azure/reliability/regions-list).
|
|
178
|
-
- **gcp**: [general-purpose](https://docs.cloud.google.com/compute/docs/general-purpose-machines?hl=en), [memory-optimized](https://docs.cloud.google.com/compute/docs/memory-optimized-machines?hl=en), [storage-optimized](https://docs.cloud.google.com/compute/docs/storage-optimized-machines?hl=en), [compute-optimized](https://docs.cloud.google.com/compute/docs/compute-optimized-machines?hl=en), [network-optimized](https://docs.cloud.google.com/compute/docs/network-optimized-machines?hl=en), [gpus](https://docs.cloud.google.com/compute/docs/accelerator-optimized-machines?hl=en), [regions](https://docs.cloud.google.com/compute/docs/regions-zones?hl=en), [carbon](https://cloud.google.com/sustainability/region-carbon).
|
|
179
|
-
- **scaleway**: [datasheet](https://www.scaleway.com/en/docs/instances/reference-content/instances-datasheet/), [zones](https://www.scaleway.com/en/developers/cli/config).
|
|
180
|
-
- **ovhcloud**: [prices](https://www.ovhcloud.com/en/public-cloud/prices/).
|
|
181
|
-
- **oracle**: [shapes](https://docs.oracle.com/en-us/iaas/Content/Compute/References/computeshapes.htm).
|
|
203
|
+
The manufacturing coefficients adapt Teads / Benjamin Davy's [article](https://medium.com/teads-engineering/building-an-aws-ec2-carbon-emissions-dataset-3f0fd76c98ac) and [Scope 3 Ratios spreadsheet](https://docs.google.com/spreadsheets/d/1DqYgQnEDLQVQm5acMAhLgHLD8xXCG9BIrk-_Nv6jF3k/edit), CC BY 4.0. Extensions and allocation rules are Digital4Better assumptions, not vendor-certified LCAs.
|
|
182
204
|
|
|
183
|
-
|
|
205
|
+
For reproducibility, see the [calculation inputs](https://github.com/digital4better/data/blob/main/scripts/cloud-host-inputs.json), [calculator](https://github.com/digital4better/data/blob/main/scripts/cloud-hosts.cjs) and [hardware source evidence](https://github.com/digital4better/data/blob/main/scripts/cloud-embodied-audit-sources.json). Detailed changes remain in [Git history](https://github.com/digital4better/data/commits/main/data/cloud) and the [correction log](https://github.com/digital4better/data/blob/main/scripts/cloud-hardware-corrections.json).
|
|
206
|
+
|
|
207
|
+
## Limitations
|
|
184
208
|
|
|
185
|
-
|
|
209
|
+
Host profiles are calculation scenarios, **not a verified inventory of deployed servers**. Actual placement, reserved resources and heterogeneous workloads can differ. Unknown mappings use explicit fallbacks; Apple desktops use a rack-equivalent proxy. Neither is a measured product footprint. Interconnects and process-node differences are not separately modeled.
|
|
186
210
|
|
|
187
|
-
|
|
211
|
+
Regions may contain several datacenters; Scaleway uses availability-zone identifiers. Local/edge zones, private realms, quota-dependent availability and every customizable VM combination are not exhaustively covered. Maximum CPU and RAM for a flexible shape do not establish a default configuration.
|
|
188
212
|
|
|
189
|
-
|
|
213
|
+
Environmental disclosures have different dates and boundaries. Missing metrics remain absent; existing estimates are not re-certified by a hardware catalog update. Apply lifetime and usage-time allocation separately when calculating a period's footprint.
|