@camstack/addon-provider-homematic 1.2.161 → 1.2.163
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/CHANGELOG.md +12 -0
- package/README.md +19 -0
- package/dist/addon.js +100846 -99473
- package/dist/addon.mjs +100845 -99449
- package/dist/index.js +2 -552
- package/dist/index.mjs +2 -551
- package/i18n/en.json +2 -2
- package/i18n/it.json +2 -2
- package/package.json +5 -5
package/CHANGELOG.md
CHANGED
|
@@ -7,6 +7,18 @@ and this project adheres to [Semantic Versioning](https://semver.org/spec/v2.0.0
|
|
|
7
7
|
|
|
8
8
|
## [Unreleased]
|
|
9
9
|
|
|
10
|
+
## [1.2.163] - 2026-10-30
|
|
11
|
+
|
|
12
|
+
### Changed
|
|
13
|
+
|
|
14
|
+
- A Homematic CCU3 / RaspberryMatic is now added as an integration (host, interfaces, optional WebUI login) with a connection test and LAN discovery, and appears as a Gateway device with a link to its WebUI; devices are adopted beside it. Remove and re-add an existing CCU.
|
|
15
|
+
|
|
16
|
+
## [1.2.162] - 2026-10-29
|
|
17
|
+
|
|
18
|
+
### Changed
|
|
19
|
+
|
|
20
|
+
- Homematic value changes now log (debug) when accepted and when dropped, with the reason
|
|
21
|
+
|
|
10
22
|
## [1.2.161] - 2026-10-28
|
|
11
23
|
|
|
12
24
|
### Changed
|
package/README.md
CHANGED
|
@@ -39,3 +39,22 @@ Edit these from System, Addons, this addon, Settings (a device's own settings ar
|
|
|
39
39
|
See [CHANGELOG.md](./CHANGELOG.md) for what changed in each version.
|
|
40
40
|
|
|
41
41
|
<!-- readme:generated:end -->
|
|
42
|
+
|
|
43
|
+
## Setup
|
|
44
|
+
|
|
45
|
+
1. In CamStack: Integrations, add **Homematic**. Pick the CCU found on your network (the scan asks each host of the
|
|
46
|
+
local /24 networks whether it is a CCU3 or RaspberryMatic WebUI) or type its **host / IP**. Choose the
|
|
47
|
+
**interfaces** to bind, and set the **callback host** if the hub has more than one address (it must be one the
|
|
48
|
+
CCU can reach, never 127.0.0.1; blank infers it). The WebUI **username and password** are optional: they unlock
|
|
49
|
+
friendly names and rooms, and the password is stored in the CamStack keychain, never in an environment variable,
|
|
50
|
+
a command line or a log line. **Test** asks every enabled interface and, with credentials, logs in.
|
|
51
|
+
2. Open the integration's discovery. The CCU appears as one **Gateway** device (online state, host, and a link to
|
|
52
|
+
its WebUI); every CCU device appears as a candidate, or as one candidate per entity under the **Entities**
|
|
53
|
+
filter. Ids carry the integration, so two CCUs never collide. Products are siblings of the gateway, not its
|
|
54
|
+
children.
|
|
55
|
+
3. A CCU that is down when CamStack starts is retried with a growing delay, and again on every integration change.
|
|
56
|
+
4. Reboot and firmware update of the CCU are not offered: the library has no call that restarts the CCU, and its
|
|
57
|
+
firmware call installs an update on a radio device by address.
|
|
58
|
+
|
|
59
|
+
Two CCUs on one hub share the default callback port (2128): give the second one another **callback port**.
|
|
60
|
+
An older broker-based CCU is not migrated: remove it and add the integration.
|