@camstack/addon-provider-homeassistant 1.2.630 → 1.2.632
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/dist/addon.js +208 -32
- package/dist/addon.mjs +208 -32
- package/dist/{dist-CT3sP-p0.mjs → dist-CPkvghX8.mjs} +383 -35
- package/dist/{dist-Dcmr-Isu.js → dist-D0ZiJUPy.js} +383 -35
- package/dist/ha-export/ha-export.addon.js +5 -1
- package/dist/ha-export/ha-export.addon.mjs +5 -1
- package/package.json +1 -1
|
@@ -24,7 +24,7 @@ var __toESM = (mod, isNodeMode, target) => (target = mod != null ? __create(__ge
|
|
|
24
24
|
enumerable: true
|
|
25
25
|
}) : target, mod));
|
|
26
26
|
//#endregion
|
|
27
|
-
const require_dist = require("../dist-
|
|
27
|
+
const require_dist = require("../dist-D0ZiJUPy.js");
|
|
28
28
|
let node_crypto = require("node:crypto");
|
|
29
29
|
require("node:zlib");
|
|
30
30
|
let node_fs = require("node:fs");
|
|
@@ -3496,6 +3496,10 @@ var CAPS_NOT_EXPORTED = [
|
|
|
3496
3496
|
cap: "meter",
|
|
3497
3497
|
reason: "The integral of a gauge that is not watts (D944). The total is base-unit seconds between resets; energy from watts is power-meter.kwhTotal. The source quantity is not on this device yet, so publishing the total as a sensor would give it no unit."
|
|
3498
3498
|
},
|
|
3499
|
+
{
|
|
3500
|
+
cap: "group-active",
|
|
3501
|
+
reason: "Whether a helper actuator group counts as active (D944): a cover is open, a lock is locked, a player is playing. Session-only, no history, and the group is not exported as the type it commands; the members are."
|
|
3502
|
+
},
|
|
3499
3503
|
{
|
|
3500
3504
|
cap: "group-commands",
|
|
3501
3505
|
reason: "The last fan-out a helper group attempted (D944), one row per member. It is session-only and has no history. The command an automation sends is the member capability (switch, brightness, colour), not this record."
|
|
@@ -1,4 +1,4 @@
|
|
|
1
|
-
import { Ft as BaseAddon, Gt as array, Ht as isReadingQuantity, I as consumableFormOf, L as consumableKindOf, Lt as baseUnitOf, O as buildAddonRouteProvider, Qt as string, U as deviceExportCapability, Ut as nodePin, Xt as object, a as COCO_TO_MACRO, c as ConsumableItemSchema, d as FanDirectionSchema, en as unknown, f as HvacModeSchema, i as CAMERA_SWITCH_ORDER, l as ConsumableStatusSchema, m as PLUG_APPLIANCE_TYPES, nn as EventCategory, o as CameraSwitchIdSchema, p as MediaPlayerRepeatSchema, s as ConsumableFormSchema, st as oauthIntegrationCapability, t as AlarmArmModeSchema, v as addonRoutesCapability } from "../dist-
|
|
1
|
+
import { Ft as BaseAddon, Gt as array, Ht as isReadingQuantity, I as consumableFormOf, L as consumableKindOf, Lt as baseUnitOf, O as buildAddonRouteProvider, Qt as string, U as deviceExportCapability, Ut as nodePin, Xt as object, a as COCO_TO_MACRO, c as ConsumableItemSchema, d as FanDirectionSchema, en as unknown, f as HvacModeSchema, i as CAMERA_SWITCH_ORDER, l as ConsumableStatusSchema, m as PLUG_APPLIANCE_TYPES, nn as EventCategory, o as CameraSwitchIdSchema, p as MediaPlayerRepeatSchema, s as ConsumableFormSchema, st as oauthIntegrationCapability, t as AlarmArmModeSchema, v as addonRoutesCapability } from "../dist-CPkvghX8.mjs";
|
|
2
2
|
import { createHmac, timingSafeEqual } from "node:crypto";
|
|
3
3
|
import "node:zlib";
|
|
4
4
|
import "node:fs";
|
|
@@ -3461,6 +3461,10 @@ var CAPS_NOT_EXPORTED = [
|
|
|
3461
3461
|
cap: "meter",
|
|
3462
3462
|
reason: "The integral of a gauge that is not watts (D944). The total is base-unit seconds between resets; energy from watts is power-meter.kwhTotal. The source quantity is not on this device yet, so publishing the total as a sensor would give it no unit."
|
|
3463
3463
|
},
|
|
3464
|
+
{
|
|
3465
|
+
cap: "group-active",
|
|
3466
|
+
reason: "Whether a helper actuator group counts as active (D944): a cover is open, a lock is locked, a player is playing. Session-only, no history, and the group is not exported as the type it commands; the members are."
|
|
3467
|
+
},
|
|
3464
3468
|
{
|
|
3465
3469
|
cap: "group-commands",
|
|
3466
3470
|
reason: "The last fan-out a helper group attempted (D944), one row per member. It is session-only and has no history. The command an automation sends is the member capability (switch, brightness, colour), not this record."
|