@camstack/addon-provider-enpal 0.1.18 → 0.1.20
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/CHANGELOG.md +13 -0
- package/README.md +3 -2
- package/dist/addon.js +11984 -2491
- package/dist/addon.mjs +11984 -2491
- package/package.json +2 -2
package/CHANGELOG.md
CHANGED
|
@@ -7,6 +7,19 @@ and this project adheres to [Semantic Versioning](https://semver.org/spec/v2.0.0
|
|
|
7
7
|
|
|
8
8
|
## [Unreleased]
|
|
9
9
|
|
|
10
|
+
## [0.1.20] - 2026-11-13
|
|
11
|
+
|
|
12
|
+
### Changed
|
|
13
|
+
|
|
14
|
+
- The System now has an Energy system device carrying every value the box reads (production, grid, house, heat pump, storage); it is the System's primary device
|
|
15
|
+
|
|
16
|
+
## [0.1.19] - 2026-11-12
|
|
17
|
+
|
|
18
|
+
### Changed
|
|
19
|
+
|
|
20
|
+
- The storage battery is a battery sensor whose reading is the state of charge, no longer a battery-powered device: no more 'battery low' notifications or battery section in the summary for it; a restored device drops the old battery capability
|
|
21
|
+
- The storage battery's past state-of-charge readings stay in its old battery history; new readings are recorded on its sensor. Nothing is migrated.
|
|
22
|
+
|
|
10
23
|
## [0.1.18] - 2026-11-12
|
|
11
24
|
|
|
12
25
|
### Changed
|
package/README.md
CHANGED
|
@@ -13,14 +13,15 @@ Pieces (the box is always offered; a container only when the box reported at lea
|
|
|
13
13
|
| Piece | Type | Sections | Children |
|
|
14
14
|
| --- | --- | --- | --- |
|
|
15
15
|
| Enpal Box | Gateway | Box, EEBUS, Connectivity | state, load and link sensors, all diagnostic; plus the link to the box's device page |
|
|
16
|
-
| System | Container | Photovoltaic, Battery, Grid, Home, Inverter | live sensors (power, level, day and lifetime energy, states) and diagnostic ones (voltages, currents, limits, ratings) |
|
|
16
|
+
| System | Container | Photovoltaic, Battery, Grid, Home, Inverter | an Energy system device carrying every value on one model (production, grid, house, heat pump, storage); live sensors (power, level, day and lifetime energy, states) and diagnostic ones (voltages, currents, limits, ratings) |
|
|
17
17
|
| Heat pump (Enpal) | Container | none | the power, consumption and temperatures Enpal reads, running states and diagnostic ones; offered only when the box reports heat-pump keys |
|
|
18
18
|
|
|
19
19
|
- A diagnostic child is hidden by default (`display.hidden`); its history is still recorded.
|
|
20
20
|
- Identity facts (model, serial numbers, firmware) are device attributes of the piece (the box's on the Gateway), never sensors.
|
|
21
21
|
- A text value (a state, a mode) is an `enum-sensor` and keeps the label the box sent; a certificate expiry is a date-time sensor.
|
|
22
22
|
- Texts and attributes come only from the web-page channel; InfluxDB and the device page carry numbers only.
|
|
23
|
-
- Each container declares which child stands for it (`primaryChildPreference`), and the framework takes the first one that was adopted: System PV power, battery level, home consumption; Heat pump power, hot water, outside temperature. An operator's own pick wins over it.
|
|
23
|
+
- Each container declares which child stands for it (`primaryChildPreference`), and the framework takes the first one that was adopted: System the Energy system, then PV power, battery level, home consumption; Heat pump power, hot water, outside temperature. An operator's own pick wins over it.
|
|
24
|
+
- The Energy system is spawned under every System, whatever was adopted with it. Its storage is a field of its model, never the `battery` capability, so a home storage never raises a low-battery alert. The box reports no day total for the heat pump: that value stays empty. Older Systems are re-stamped with the new preference at start, so the Energy system becomes their primary child unless the operator picked one.
|
|
24
25
|
- Not exposed on purpose: AC consumption duplicate, AC maximum, the network-traffic, cellular-guard and predictor internals.
|
|
25
26
|
|
|
26
27
|
Removing the integration removes its devices. An unreachable box marks its devices offline; it never publishes zeros. A lifetime counter that drops for one poll is held at its previous value.
|