@bentley/substation-symbols-custom-schema 1.0.5-dev.1

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
package/LICENSE.md ADDED
@@ -0,0 +1,9 @@
1
+ # MIT License
2
+
3
+ Copyright © 2017-2026 Bentley Systems, Incorporated. All rights reserved.
4
+
5
+ Permission is hereby granted, free of charge, to any person obtaining a copy of this software and associated documentation files (the "Software"), to deal in the Software without restriction, including without limitation the rights to use, copy, modify, merge, publish, distribute, sublicense, and/or sell copies of the Software, and to permit persons to whom the Software is furnished to do so, subject to the following conditions:
6
+
7
+ The above copyright notice and this permission notice shall be included in all copies or substantial portions of the Software.
8
+
9
+ THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE.
package/README.md ADDED
@@ -0,0 +1,9 @@
1
+ # @bentley/substation-symbols-custom-schema
2
+
3
+ Copyright © Bentley Systems, Incorporated. All rights reserved. See [LICENSE.md](./LICENSE.md) for license terms and full copyright notice.
4
+
5
+ [iTwin.js](http://itwinjs.org) is an open source platform for creating, querying, modifying, and displaying Infrastructure Digital Twins.
6
+
7
+ ## BIS Schemas
8
+
9
+ The acronym “BIS” stands for “Base Infrastructure Schemas”. BIS is an “open” and extensible family of schemas that is modularized into Domains. Please go to [iTwinjs.org](https://www.itwinjs.org/bis/) for more information.
@@ -0,0 +1 @@
1
+ {"$schema":"https://dev.bentley.com/json_schemas/ec/32/ecschema","name":"SubstationSymbolsCustom","version":"01.00.05","alias":"subsymc","label":"SubstationSymbolsCustom","description":"This schema contains classes used for Substation Design.","references":[{"name":"BisCore","version":"01.00.26"},{"name":"PowerSystemResourcesPhysical","version":"01.00.01"},{"name":"SubstationPhysical","version":"01.00.05"},{"name":"SubstationSymbols","version":"01.00.05"},{"name":"CoreCustomAttributes","version":"01.00.05"},{"name":"BisCustomAttributes","version":"01.00.00"},{"name":"SubstationInformation","version":"01.00.05"}],"customAttributes":[{"className":"CoreCustomAttributes.DynamicSchema"},{"className":"CoreCustomAttributes.ProductionStatus","SupportedUse":"NotForProduction"},{"className":"BisCustomAttributes.SchemaLayerInfo","Value":"Application"}],"items":{"EquipmentSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Equipment Symbols Physical Type Aspect","description":"Contains custom properties of a Equipment Symbols Physical Type Aspect.","baseClass":"PowerSystemResourcesPhysical.EquipmentPhysicalTypeAspect","properties":[{"name":"Name","type":"PrimitiveProperty","label":"Name","typeName":"string"},{"name":"Description","type":"PrimitiveProperty","label":"Description","typeName":"string"},{"name":"DetailedDescription1","type":"PrimitiveProperty","label":"Short Description","typeName":"string"},{"name":"TagMnemonic","type":"PrimitiveProperty","label":"Tag Mnemonic","typeName":"string"},{"name":"Family","type":"PrimitiveProperty","label":"Family","typeName":"string"},{"name":"IsGeneric","type":"PrimitiveProperty","description":"If true, this is a generic representation rather than a specific part.","label":"Is Generic","typeName":"boolean"},{"name":"SymbolType","type":"PrimitiveProperty","label":"Symbol Type","typeName":"SubstationInformation.SymbolType"},{"name":"QuantityPerUnit","type":"PrimitiveProperty","label":"Quantity Per Unit","typeName":"string"},{"name":"UnitOfMeasure","type":"PrimitiveProperty","label":"Unit Of Measure","typeName":"string"},{"name":"OrderUnit","type":"PrimitiveProperty","label":"Order Unit","typeName":"string"},{"name":"BuyingPrice","type":"PrimitiveProperty","label":"Buying Price","typeName":"string"},{"name":"DimensionX","type":"PrimitiveProperty","label":"Dimension X","typeName":"string"},{"name":"DimensionY","type":"PrimitiveProperty","label":"Dimension Y","typeName":"string"},{"name":"DimensionZ","type":"PrimitiveProperty","label":"Dimension Z","typeName":"string"},{"name":"DateCreated","type":"PrimitiveProperty","label":"Date Created","typeName":"dateTime"},{"name":"DateModified","type":"PrimitiveProperty","label":"Date Modified","typeName":"dateTime"}]},"StructureSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Structure Symbols Physical Type Aspect","description":"Contains custom properties of a Structure Symbols Physical Type Aspect.","baseClass":"PowerSystemResourcesPhysical.StructurePhysicalTypeAspect","properties":[{"name":"Name","type":"PrimitiveProperty","label":"Name","typeName":"string"},{"name":"Description","type":"PrimitiveProperty","label":"Description","typeName":"string"},{"name":"DetailedDescription1","type":"PrimitiveProperty","label":"Short Description","typeName":"string"},{"name":"TagMnemonic","type":"PrimitiveProperty","label":"Tag Mnemonic","typeName":"string"},{"name":"Family","type":"PrimitiveProperty","label":"Family","typeName":"string"},{"name":"IsGeneric","type":"PrimitiveProperty","description":"If true, this is a generic representation rather than a specific part.","label":"Is Generic","typeName":"boolean"},{"name":"SymbolType","type":"PrimitiveProperty","label":"Symbol Type","typeName":"SubstationInformation.SymbolType"},{"name":"QuantityPerUnit","type":"PrimitiveProperty","label":"Quantity Per Unit","typeName":"string"},{"name":"UnitOfMeasure","type":"PrimitiveProperty","label":"Unit Of Measure","typeName":"string"},{"name":"OrderUnit","type":"PrimitiveProperty","label":"Order Unit","typeName":"string"},{"name":"BuyingPrice","type":"PrimitiveProperty","label":"Buying Price","typeName":"string"},{"name":"DimensionX","type":"PrimitiveProperty","label":"Dimension X","typeName":"string"},{"name":"DimensionY","type":"PrimitiveProperty","label":"Dimension Y","typeName":"string"},{"name":"DimensionZ","type":"PrimitiveProperty","label":"Dimension Z","typeName":"string"},{"name":"DateCreated","type":"PrimitiveProperty","label":"Date Created","typeName":"dateTime"},{"name":"DateModified","type":"PrimitiveProperty","label":"Date Modified","typeName":"dateTime"}]},"FoundationSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Foundation Symbols Physical Type Aspect","description":"Contains custom properties of a Foundation Symbols Physical Type Aspect.","baseClass":"PowerSystemResourcesPhysical.FoundationPhysicalTypeAspect","properties":[{"name":"Name","type":"PrimitiveProperty","label":"Name","typeName":"string"},{"name":"Description","type":"PrimitiveProperty","label":"Description","typeName":"string"},{"name":"DetailedDescription1","type":"PrimitiveProperty","label":"Short Description","typeName":"string"},{"name":"TagMnemonic","type":"PrimitiveProperty","label":"Tag Mnemonic","typeName":"string"},{"name":"Family","type":"PrimitiveProperty","label":"Family","typeName":"string"},{"name":"IsGeneric","type":"PrimitiveProperty","description":"If true, this is a generic representation rather than a specific part.","label":"Is Generic","typeName":"boolean"},{"name":"SymbolType","type":"PrimitiveProperty","label":"Symbol Type","typeName":"SubstationInformation.SymbolType"},{"name":"QuantityPerUnit","type":"PrimitiveProperty","label":"Quantity Per Unit","typeName":"string"},{"name":"UnitOfMeasure","type":"PrimitiveProperty","label":"Unit Of Measure","typeName":"string"},{"name":"OrderUnit","type":"PrimitiveProperty","label":"Order Unit","typeName":"string"},{"name":"BuyingPrice","type":"PrimitiveProperty","label":"Buying Price","typeName":"string"},{"name":"DimensionX","type":"PrimitiveProperty","label":"Dimension X","typeName":"string"},{"name":"DimensionY","type":"PrimitiveProperty","label":"Dimension Y","typeName":"string"},{"name":"DimensionZ","type":"PrimitiveProperty","label":"Dimension Z","typeName":"string"},{"name":"DateCreated","type":"PrimitiveProperty","label":"Date Created","typeName":"dateTime"},{"name":"DateModified","type":"PrimitiveProperty","label":"Date Modified","typeName":"dateTime"}]},"SubstationSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Substation Symbols Physical Type Aspect","description":"Contains custom properties of a Substation Symbols Physical Type Aspect.","baseClass":"SubstationPhysical.SubstationPhysicalTypeAspect","properties":[{"name":"Name","type":"PrimitiveProperty","label":"Name","typeName":"string"},{"name":"Description","type":"PrimitiveProperty","label":"Description","typeName":"string"},{"name":"DetailedDescription1","type":"PrimitiveProperty","label":"Short Description","typeName":"string"},{"name":"TagMnemonic","type":"PrimitiveProperty","label":"Tag Mnemonic","typeName":"string"},{"name":"Family","type":"PrimitiveProperty","label":"Family","typeName":"string"},{"name":"IsGeneric","type":"PrimitiveProperty","description":"If true, this is a generic representation rather than a specific part.","label":"Is Generic","typeName":"boolean"},{"name":"SymbolType","type":"PrimitiveProperty","label":"Symbol Type","typeName":"SubstationInformation.SymbolType"},{"name":"QuantityPerUnit","type":"PrimitiveProperty","label":"Quantity Per Unit","typeName":"string"},{"name":"UnitOfMeasure","type":"PrimitiveProperty","label":"Unit Of Measure","typeName":"string"},{"name":"OrderUnit","type":"PrimitiveProperty","label":"Order Unit","typeName":"string"},{"name":"BuyingPrice","type":"PrimitiveProperty","label":"Buying Price","typeName":"string"},{"name":"DimensionX","type":"PrimitiveProperty","label":"Dimension X","typeName":"string"},{"name":"DimensionY","type":"PrimitiveProperty","label":"Dimension Y","typeName":"string"},{"name":"DimensionZ","type":"PrimitiveProperty","label":"Dimension Z","typeName":"string"},{"name":"DateCreated","type":"PrimitiveProperty","label":"Date Created","typeName":"dateTime"},{"name":"DateModified","type":"PrimitiveProperty","label":"Date Modified","typeName":"dateTime"}]},"EquipmentSymbolsPhysicalTypeOwnsEquipmentSymbolsPhysicalTypeAspect":{"schemaItemType":"RelationshipClass","modifier":"None","baseClass":"BisCore.ElementOwnsUniqueAspect","strength":"Embedding","strengthDirection":"Forward","source":{"multiplicity":"(1..1)","roleLabel":"owns","polymorphic":true,"constraintClasses":["SubstationSymbols.EquipmentSymbolsPhysicalType"]},"target":{"multiplicity":"(0..*)","roleLabel":"is owned by","polymorphic":true,"constraintClasses":["SubstationSymbolsCustom.EquipmentSymbolsPhysicalTypeAspect"]}},"StructureSymbolsPhysicalTypeOwnsStructureSymbolsPhysicalTypeAspect":{"schemaItemType":"RelationshipClass","modifier":"None","baseClass":"BisCore.ElementOwnsUniqueAspect","strength":"Embedding","strengthDirection":"Forward","source":{"multiplicity":"(1..1)","roleLabel":"owns","polymorphic":true,"constraintClasses":["SubstationSymbols.StructureSymbolsPhysicalType"]},"target":{"multiplicity":"(0..*)","roleLabel":"is owned by","polymorphic":true,"constraintClasses":["SubstationSymbolsCustom.StructureSymbolsPhysicalTypeAspect"]}},"FoundationSymbolsPhysicalTypeOwnsFoundationSymbolsPhysicalTypeAspect":{"schemaItemType":"RelationshipClass","modifier":"None","baseClass":"BisCore.ElementOwnsUniqueAspect","strength":"Embedding","strengthDirection":"Forward","source":{"multiplicity":"(1..1)","roleLabel":"owns","polymorphic":true,"constraintClasses":["SubstationSymbols.FoundationSymbolsPhysicalType"]},"target":{"multiplicity":"(0..*)","roleLabel":"is owned by","polymorphic":true,"constraintClasses":["SubstationSymbolsCustom.FoundationSymbolsPhysicalTypeAspect"]}},"SubstationSymbolsPhysicalTypeOwnsSubstationSymbolsPhysicalTypeAspect":{"schemaItemType":"RelationshipClass","modifier":"None","baseClass":"BisCore.ElementOwnsUniqueAspect","strength":"Embedding","strengthDirection":"Forward","source":{"multiplicity":"(1..1)","roleLabel":"owns","polymorphic":true,"constraintClasses":["SubstationSymbols.SubstationSymbolsPhysicalType"]},"target":{"multiplicity":"(0..*)","roleLabel":"is owned by","polymorphic":true,"constraintClasses":["SubstationSymbolsCustom.SubstationSymbolsPhysicalTypeAspect"]}},"SwitchSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Switch","description":"A generic device designed to close, or open, or both, one or more electric circuits. All switches are two terminal devices including grounding switches. The ACDCTerminal.connected at the two sides of the switch shall not be considered for assessing switch connectivity, i.e. only Switch.open, .normalOpen and .locked are relevant.","baseClass":"SubstationSymbolsCustom.EquipmentSymbolsPhysicalTypeAspect","properties":[{"name":"ShortDescription","type":"PrimitiveProperty","label":"Short Description","typeName":"string"},{"name":"NominalVoltage","type":"PrimitiveProperty","label":"Nominal Voltage","typeName":"string"}]},"SectionalizerSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Sectionalizer","description":"Automatic switch that will lock open to isolate a faulted section. It may, or may not, have load breaking capability. Its primary purpose is to provide fault sectionalising at locations where the fault current is either too high, or too low, for proper coordination of fuses.","baseClass":"SubstationSymbolsCustom.SwitchSymbolsPhysicalTypeAspect"},"CutSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Cut","description":"A cut separates a line segment into two parts. The cut appears as a switch inserted between these two parts and connects them together. As the cut is normally open there is no galvanic connection between the two line segment parts. But it is possible to close the cut to get galvanic connection.\r The cut terminals are oriented towards the line segment terminals with the same sequence number. Hence the cut terminal with sequence number equal to 1 is oriented to the line segment's terminal with sequence number equal to 1.\r The cut terminals also act as connection points for jumpers and other equipment, e.g. a mobile generator. To enable this, connectivity nodes are placed at the cut terminals. Once the connectivity nodes are in place any conducting equipment can be connected at them.","baseClass":"SubstationSymbolsCustom.SwitchSymbolsPhysicalTypeAspect"},"JumperSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Jumper","description":"A short section of conductor with negligible impedance which can be manually removed and replaced if the circuit is de-energized. Note that zero-impedance branches can potentially be modelled by other equipment types.","baseClass":"SubstationSymbolsCustom.SwitchSymbolsPhysicalTypeAspect","properties":[{"name":"TradeDiameter","type":"PrimitiveProperty","label":"Trade Diameter","typeName":"string"},{"name":"MaxContCurrent","type":"PrimitiveProperty","label":"Max Continuous Current","typeName":"string"},{"name":"RatedShortTimeCurrent","type":"PrimitiveProperty","label":"Rated short time current","typeName":"string"},{"name":"CableCode","type":"PrimitiveProperty","label":"Cable Code","typeName":"string"},{"name":"MinBendingRadius","type":"PrimitiveProperty","label":"Minimum Bending Radius","typeName":"string"}]},"FuseSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Fuse","description":"An overcurrent protective device with a circuit opening fusible part that is heated and severed by the passage of overcurrent through it. A fuse is considered a switching device because it breaks current.","baseClass":"SubstationSymbolsCustom.SwitchSymbolsPhysicalTypeAspect","properties":[{"name":"Mounting","type":"PrimitiveProperty","label":"Mounting Method","typeName":"string"},{"name":"FuseRatings","type":"PrimitiveProperty","label":"Fuse Ratings","typeName":"string"},{"name":"InterruptingCapacityAmpsAssymetrical","type":"PrimitiveProperty","label":"Interrupting Capacity Amps Assymetrical","typeName":"string"},{"name":"InterruptingCapacityAmpsSymetrical","type":"PrimitiveProperty","label":"Interrupting Capacity Amps Symetrical","typeName":"string"}]},"GroundDisconnectorSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Ground Disconnector","description":"A manually operated or motor operated mechanical switching device used for isolating a circuit or equipment from ground.\r Also known as earthing switch","baseClass":"SubstationSymbolsCustom.SwitchSymbolsPhysicalTypeAspect","properties":[{"name":"MechanicalEnduranceClass","type":"PrimitiveProperty","label":"Mechanical Endurance Class","typeName":"string"},{"name":"InsulatorType","type":"PrimitiveProperty","label":"Insulator Type","typeName":"string"},{"name":"RatedShortTimeCurrent","type":"PrimitiveProperty","label":"Rated short time current","typeName":"string"}]},"DisconnectorSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Disconnector","description":"A manually operated or motor operated mechanical switching device used for changing the connections in a circuit, or for isolating a circuit or equipment from a source of power. It is required to open or close circuits when negligible current is broken or made.","baseClass":"SubstationSymbolsCustom.SwitchSymbolsPhysicalTypeAspect","properties":[{"name":"MechanicalEnduranceClass","type":"PrimitiveProperty","label":"Mechanical Endurance Class","typeName":"string"},{"name":"InsulatorType","type":"PrimitiveProperty","label":"Insulator Type","typeName":"string"},{"name":"MaxContCurrent","type":"PrimitiveProperty","label":"Max Continuous Current","typeName":"string"},{"name":"RatedShortTimeCurrent","type":"PrimitiveProperty","label":"Rated short time current","typeName":"string"},{"name":"ShortTimeWithstandCurrent","type":"PrimitiveProperty","label":"Short Time Withstand Current","typeName":"string"},{"name":"ShortTimeCurrentRatedDuration","type":"PrimitiveProperty","label":"Rated Duration of Short Circuit at short-time current","typeName":"string"}]},"ProtectedSwitchSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Protected Switch","description":"A ProtectedSwitch is a switching device that can be operated by ProtectionEquipment.\r ","baseClass":"SubstationSymbolsCustom.SwitchSymbolsPhysicalTypeAspect","properties":[{"name":"WithstandKV","type":"PrimitiveProperty","label":"Withstand KV","typeName":"string"},{"name":"MechanicalEnduranceClass","type":"PrimitiveProperty","label":"Mechanical Endurance Class","typeName":"string"},{"name":"InsulatorType","type":"PrimitiveProperty","label":"Insulator Type","typeName":"string"},{"name":"InterruptingCurrent","type":"PrimitiveProperty","label":"Interrupting Current","typeName":"string"},{"name":"MaxContCurrent","type":"PrimitiveProperty","label":"Max Continuous Current","typeName":"string"},{"name":"RatedShortTimeCurrent","type":"PrimitiveProperty","label":"Rated short time current","typeName":"string"},{"name":"NumberOfPhases","type":"PrimitiveProperty","label":"Number of Phases","typeName":"string"},{"name":"InterruptingCapacityAmpsAssymetrical","type":"PrimitiveProperty","label":"Interrupting Capacity Amps Assymetrical","typeName":"string"},{"name":"InterruptingCapacityAmpsSymetrical","type":"PrimitiveProperty","label":"Interrupting Capacity Amps Symetrical","typeName":"string"},{"name":"ShortTimeWithstandCurrent","type":"PrimitiveProperty","label":"Short Time Withstand Current","typeName":"string"},{"name":"ShortTimeCurrentRatedDuration","type":"PrimitiveProperty","label":"Rated Duration of Short Circuit at short-time current","typeName":"string"}]},"AuxiliaryEquipmentSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Auxiliary Equipment","description":"AuxiliaryEquipment describe equipment that is not performing any primary functions but support for the equipment performing the primary function.\r AuxiliaryEquipment is attached to primary equipment via an association with Terminal.","baseClass":"SubstationSymbolsCustom.EquipmentSymbolsPhysicalTypeAspect","properties":[{"name":"ShortDescription","type":"PrimitiveProperty","label":"Short Description","typeName":"string"}]},"BreakerSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Breaker","baseClass":"SubstationSymbolsCustom.ProtectedSwitchSymbolsPhysicalTypeAspect","properties":[{"name":"ReclosingTime","type":"PrimitiveProperty","label":"Reclosing Time","typeName":"string"},{"name":"InTransientTime","type":"PrimitiveProperty","label":"In Transient Time","typeName":"string"}]},"RecloserSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Recloser","description":"Pole-mounted fault interrupter with built-in phase and ground relays, current transformer (CT), and supplemental controls.","baseClass":"SubstationSymbolsCustom.ProtectedSwitchSymbolsPhysicalTypeAspect","properties":[{"name":"ReclosingTime","type":"PrimitiveProperty","label":"Reclosing Time","typeName":"string"}]},"LoadBreakSwitchSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Load Break Switch","description":"A mechanical switching device capable of making, carrying, and breaking currents under normal operating conditions.","baseClass":"SubstationSymbolsCustom.ProtectedSwitchSymbolsPhysicalTypeAspect"},"SurgeArresterSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Surge Arrester","description":"Shunt device, installed on the network, usually in the proximity of electrical equipment in order to protect the said equipment against transient voltage transients caused by lightning or switching activity.","baseClass":"SubstationSymbolsCustom.AuxiliaryEquipmentSymbolsPhysicalTypeAspect","properties":[{"name":"RatedShortTimeCurrent","type":"PrimitiveProperty","label":"Rated short time current","typeName":"string"},{"name":"ArresterClass","type":"PrimitiveProperty","label":"Arrester Class","typeName":"string"},{"name":"Mounting","type":"PrimitiveProperty","label":"Mounting Method","typeName":"string"},{"name":"MCOV","type":"PrimitiveProperty","label":"Maximum Continuous Operating Voltage","typeName":"string"}]},"FaultIndicatorSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Fault Indicator","description":"A FaultIndicator is typically only an indicator (which may or may not be remotely monitored), and not a piece of equipment that actually initiates a protection event. It is used for FLISR (Fault Location, Isolation and Restoration) purposes, assisting with the dispatch of crews to \"most likely\" part of the network (i.e. assists with determining circuit section where the fault most likely happened).","baseClass":"SubstationSymbolsCustom.AuxiliaryEquipmentSymbolsPhysicalTypeAspect"},"WaveTrapSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Wave Trap","description":"Line traps are devices that impede high frequency power line carrier signals yet present a negligible impedance at the main power frequency.","baseClass":"SubstationSymbolsCustom.AuxiliaryEquipmentSymbolsPhysicalTypeAspect","properties":[{"name":"NominalVoltage","type":"PrimitiveProperty","label":"Nominal Voltage","typeName":"string"},{"name":"WithstandKV","type":"PrimitiveProperty","label":"Withstand KV","typeName":"string"},{"name":"InsulatorType","type":"PrimitiveProperty","label":"Insulator Type","typeName":"string"},{"name":"MaxContCurrent","type":"PrimitiveProperty","label":"Max Continuous Current","typeName":"string"},{"name":"TypeOfCooling","type":"PrimitiveProperty","label":"Type Of Cooling","typeName":"string"},{"name":"Mounting","type":"PrimitiveProperty","label":"Mounting Method","typeName":"string"}]},"InsulatorSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Insulator","baseClass":"SubstationSymbolsCustom.AuxiliaryEquipmentSymbolsPhysicalTypeAspect","properties":[{"name":"NominalVoltage","type":"PrimitiveProperty","label":"Nominal Voltage","typeName":"string"},{"name":"WithstandKV","type":"PrimitiveProperty","label":"Withstand KV","typeName":"string"},{"name":"MechanicalEnduranceClass","type":"PrimitiveProperty","label":"Mechanical Endurance Class","typeName":"string"},{"name":"InsulatorType","type":"PrimitiveProperty","label":"Insulator Type","typeName":"string"},{"name":"InsulationType","type":"PrimitiveProperty","label":"Insulation Type","typeName":"string"},{"name":"Mounting","type":"PrimitiveProperty","label":"Mounting Method","typeName":"string"}]},"SensorSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Sensor","description":"AuxiliaryEquipment describes equipment that does not perform primary functions but supports equipment that does.","baseClass":"SubstationSymbolsCustom.AuxiliaryEquipmentSymbolsPhysicalTypeAspect"},"EarthFaultCompensatorSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Earth Fault Compensator","description":"A conducting equipment used to represent a connection to ground which is typically used to compensate earth faults. An earth fault compensator device modelled with a single terminal implies a second terminal solidly connected to ground. If two terminals are modelled, the ground is not assumed and normal connection rules apply.\r ","baseClass":"SubstationSymbolsCustom.EquipmentSymbolsPhysicalTypeAspect","properties":[{"name":"ShortDescription","type":"PrimitiveProperty","label":"Short Description","typeName":"string"},{"name":"NominalVoltage","type":"PrimitiveProperty","label":"Nominal Voltage","typeName":"string"},{"name":"WithstandKV","type":"PrimitiveProperty","label":"Withstand KV","typeName":"string"},{"name":"InsulatorType","type":"PrimitiveProperty","label":"Insulator Type","typeName":"string"}]},"DisconnectingCircuitBreakerSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Circuit Breaker With Disconnector","description":"A circuit breaking device including disconnecting function, eliminating the need for separate disconnectors.","baseClass":"SubstationSymbolsCustom.BreakerSymbolsPhysicalTypeAspect"},"PotentialTransformerSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Potential Transformer","description":"AuxiliaryEquipment describe equipment that is not performing any primary functions but support for the equipment performing the primary function.\r AuxiliaryEquipment is attached to primary equipment via an association with Terminal.","baseClass":"SubstationSymbolsCustom.SensorSymbolsPhysicalTypeAspect","properties":[{"name":"NominalVoltage","type":"PrimitiveProperty","label":"Nominal Voltage","typeName":"string"},{"name":"WithstandKV","type":"PrimitiveProperty","label":"Withstand KV","typeName":"string"},{"name":"InsulatorType","type":"PrimitiveProperty","label":"Insulator Type","typeName":"string"},{"name":"InsulationType","type":"PrimitiveProperty","label":"Insulation Type","typeName":"string"},{"name":"FluidType","type":"PrimitiveProperty","label":"Fluid Type","typeName":"string"},{"name":"PrimaryVoltage","type":"PrimitiveProperty","label":"Primary Voltage","typeName":"string"},{"name":"SecondaryVoltage","type":"PrimitiveProperty","label":"Secondary Voltage","typeName":"string"},{"name":"TypeOfCooling","type":"PrimitiveProperty","label":"Type Of Cooling","typeName":"string"},{"name":"Mounting","type":"PrimitiveProperty","label":"Mounting Method","typeName":"string"},{"name":"VoltageFactor","type":"PrimitiveProperty","label":"Voltage Factor","typeName":"string"},{"name":"ThermalBurden","type":"PrimitiveProperty","label":"Thermal Burden","typeName":"string"},{"name":"PTRatio","type":"PrimitiveProperty","label":"PT Ratio","typeName":"string"},{"name":"WindingRatio","type":"PrimitiveProperty","label":"Winding Ratio","typeName":"string"},{"name":"RatingFactor","type":"PrimitiveProperty","label":"Rating Factor","typeName":"string"},{"name":"BurdenRating","type":"PrimitiveProperty","label":"Burden Rating","typeName":"string"}]},"CurrentTransformerSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Current Transformer","baseClass":"SubstationSymbolsCustom.SensorSymbolsPhysicalTypeAspect","properties":[{"name":"NominalVoltage","type":"PrimitiveProperty","label":"Nominal Voltage","typeName":"string"},{"name":"WithstandKV","type":"PrimitiveProperty","label":"Withstand KV","typeName":"string"},{"name":"InsulatorType","type":"PrimitiveProperty","label":"Insulator Type","typeName":"string"},{"name":"RatedShortTimeCurrent","type":"PrimitiveProperty","label":"Rated short time current","typeName":"string"},{"name":"InsulationType","type":"PrimitiveProperty","label":"Insulation Type","typeName":"string"},{"name":"FluidType","type":"PrimitiveProperty","label":"Fluid Type","typeName":"string"},{"name":"TypeOfCooling","type":"PrimitiveProperty","label":"Type Of Cooling","typeName":"string"},{"name":"Mounting","type":"PrimitiveProperty","label":"Mounting Method","typeName":"string"},{"name":"PrimaryCurrent","type":"PrimitiveProperty","label":"Primary Current","typeName":"string"},{"name":"SecondaryCurrent","type":"PrimitiveProperty","label":"Secondary Current","typeName":"string"},{"name":"CTRatio","type":"PrimitiveProperty","label":"CT Ratio","typeName":"string"},{"name":"VoltageFactor","type":"PrimitiveProperty","label":"Voltage Factor","typeName":"string"},{"name":"ThermalBurden","type":"PrimitiveProperty","label":"Thermal Burden","typeName":"string"},{"name":"WindingRatio","type":"PrimitiveProperty","label":"Winding Ratio","typeName":"string"},{"name":"RatingFactor","type":"PrimitiveProperty","label":"Rating Factor","typeName":"string"},{"name":"BurdenRating","type":"PrimitiveProperty","label":"Burden Rating","typeName":"string"}]},"PostLineSensorSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Post Line Sensor","description":"A sensor used mainly in overhead distribution networks as the source of both current and voltage measurements","baseClass":"SubstationSymbolsCustom.SensorSymbolsPhysicalTypeAspect"},"GroundingImpedanceSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Grounding Impedance","description":"A fixed impedance device used for grounding.\r ","baseClass":"SubstationSymbolsCustom.EarthFaultCompensatorSymbolsPhysicalTypeAspect","properties":[{"name":"MaxContCurrent","type":"PrimitiveProperty","label":"Max Continuous Current","typeName":"string"},{"name":"InsulationType","type":"PrimitiveProperty","label":"Insulation Type","typeName":"string"},{"name":"AllowableAmpacity","type":"PrimitiveProperty","label":"Allowable Ampacity","typeName":"string"},{"name":"Mounting","type":"PrimitiveProperty","label":"Mounting Method","typeName":"string"},{"name":"ShortTimeWithstandCurrent","type":"PrimitiveProperty","label":"Short Time Withstand Current","typeName":"string"},{"name":"ReactivePower","type":"PrimitiveProperty","label":"Reactive Power","typeName":"string"}]},"PetersenCoilSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Petersen Coil","description":"A variable impedance device normally used to offset line charging during single line faults in an ungrounded section of network.","baseClass":"SubstationSymbolsCustom.EarthFaultCompensatorSymbolsPhysicalTypeAspect","properties":[{"name":"TypeOfCooling","type":"PrimitiveProperty","label":"Type Of Cooling","typeName":"string"},{"name":"FullLoadKVA","type":"PrimitiveProperty","label":"Full Load KVA","typeName":"string"},{"name":"RatedPower","type":"PrimitiveProperty","label":"Rated Power","typeName":"string"}]},"TransformerSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Transformer","description":"Power transformers are utilized in transmission networks with significantly higher voltage, while distribution transformers function in distribution networks defined by lower voltages","baseClass":"SubstationSymbolsCustom.EquipmentSymbolsPhysicalTypeAspect","properties":[{"name":"ShortDescription","type":"PrimitiveProperty","label":"Short Description","typeName":"string"},{"name":"FluidType","type":"PrimitiveProperty","label":"Fluid Type","typeName":"string"},{"name":"PrimaryVoltage","type":"PrimitiveProperty","label":"Primary Voltage","typeName":"string"},{"name":"TypeOfCooling","type":"PrimitiveProperty","label":"Type Of Cooling","typeName":"string"},{"name":"FullLoadKVA","type":"PrimitiveProperty","label":"Full Load KVA","typeName":"string"},{"name":"RatedPower","type":"PrimitiveProperty","label":"Rated Power","typeName":"string"},{"name":"TemperatureRiseOil","type":"PrimitiveProperty","label":"Temperature Rise in Oil","typeName":"string"},{"name":"TemperatureRiseWindings","type":"PrimitiveProperty","label":"Temperature Rise in Windings","typeName":"string"},{"name":"PrimaryWindingBIL","type":"PrimitiveProperty","label":"Primary Winding BIL","typeName":"string"},{"name":"PrimaryPower","type":"PrimitiveProperty","label":"Primary Power","typeName":"string"},{"name":"ReactivePower","type":"PrimitiveProperty","label":"Reactive Power","typeName":"string"},{"name":"ImpedanceBase","type":"PrimitiveProperty","label":"Impedance Base","typeName":"string"},{"name":"PrimaryBushingBIL","type":"PrimitiveProperty","label":"Primary Bushing BIL","typeName":"string"},{"name":"PrimaryNeutralBIL","type":"PrimitiveProperty","label":"Primary Neutral BIL","typeName":"string"},{"name":"PrimaryArresterRating","type":"PrimitiveProperty","label":"Primary Arrester Rating","typeName":"string"}]},"PowerTransformerSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Power Transformer","baseClass":"SubstationSymbolsCustom.TransformerSymbolsPhysicalTypeAspect"},"CompensatorSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Compensator","description":"A Series Compensator is a series capacitor or reactor or an AC transmission line without charging susceptance. It is a two terminal device.","baseClass":"SubstationSymbolsCustom.EquipmentSymbolsPhysicalTypeAspect","properties":[{"name":"ShortDescription","type":"PrimitiveProperty","label":"Short Description","typeName":"string"},{"name":"NominalVoltage","type":"PrimitiveProperty","label":"Nominal Voltage","typeName":"string"},{"name":"WithstandKV","type":"PrimitiveProperty","label":"Withstand KV","typeName":"string"},{"name":"InsulatorType","type":"PrimitiveProperty","label":"Insulator Type","typeName":"string"},{"name":"MaxContCurrent","type":"PrimitiveProperty","label":"Max Continuous Current","typeName":"string"},{"name":"RatedShortTimeCurrent","type":"PrimitiveProperty","label":"Rated short time current","typeName":"string"},{"name":"TypeOfCooling","type":"PrimitiveProperty","label":"Type Of Cooling","typeName":"string"},{"name":"FullLoadKVA","type":"PrimitiveProperty","label":"Full Load KVA","typeName":"string"},{"name":"ReactivePower","type":"PrimitiveProperty","label":"Reactive Power","typeName":"string"}]},"SeriesCompensatorSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Series Compensator","description":"A Series Compensator is a series capacitor or reactor or an AC transmission line without charging susceptance. It is a two terminal device.","baseClass":"SubstationSymbolsCustom.CompensatorSymbolsPhysicalTypeAspect"},"ConductorSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Conductor","baseClass":"SubstationSymbolsCustom.EquipmentSymbolsPhysicalTypeAspect","properties":[{"name":"ShortDescription","type":"PrimitiveProperty","label":"Short Description","typeName":"string"},{"name":"PercentSpare","type":"PrimitiveProperty","label":"Percent Spare","typeName":"int"},{"name":"TradeDiameter","type":"PrimitiveProperty","label":"Trade Diameter","typeName":"string"},{"name":"CableCode","type":"PrimitiveProperty","label":"Cable Code","typeName":"string"},{"name":"AllowableAmpacity","type":"PrimitiveProperty","label":"Allowable Ampacity","typeName":"string"},{"name":"OuterDiameter","type":"PrimitiveProperty","label":"Outside Diameter","typeName":"string"},{"name":"MinBendingRadius","type":"PrimitiveProperty","label":"Minimum Bending Radius","typeName":"string"},{"name":"RatedPower","type":"PrimitiveProperty","label":"Rated Power","typeName":"string"},{"name":"NumberofConductors","type":"PrimitiveProperty","label":"Number of Conductors","typeName":"string"}]},"ClampSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Clamp","baseClass":"SubstationSymbolsCustom.EquipmentSymbolsPhysicalTypeAspect","properties":[{"name":"ShortDescription","type":"PrimitiveProperty","label":"Short Description","typeName":"string"},{"name":"NominalVoltage","type":"PrimitiveProperty","label":"Nominal Voltage","typeName":"string"},{"name":"AllowableAmpacity","type":"PrimitiveProperty","label":"Allowable Ampacity","typeName":"string"},{"name":"InstallationMethod","type":"PrimitiveProperty","label":"Installation Method","typeName":"string"}]},"ConnectorSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Connector","description":"A conductor, or group of conductors, with negligible impedance, that serve to connect other conducting equipment within a single substation and are modelled with a single logical terminal.","baseClass":"SubstationSymbolsCustom.EquipmentSymbolsPhysicalTypeAspect","properties":[{"name":"ShortDescription","type":"PrimitiveProperty","label":"Short Description","typeName":"string"},{"name":"NominalVoltage","type":"PrimitiveProperty","label":"Nominal Voltage","typeName":"string"},{"name":"AllowableAmpacity","type":"PrimitiveProperty","label":"Allowable Ampacity","typeName":"string"}]},"BusbarSectionSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Busbar Section","description":"A conductor, or group of conductors, with negligible impedance, that serve to connect other conducting equipment within a single substation. \r Voltage measurements are typically obtained from voltage transformers that are connected to busbar sections. A bus bar section may have many physical terminals but for analysis is modelled with exactly one logical terminal.","baseClass":"SubstationSymbolsCustom.ConnectorSymbolsPhysicalTypeAspect","properties":[{"name":"TradeDiameter","type":"PrimitiveProperty","label":"Trade Diameter","typeName":"string"},{"name":"InnerDiameter","type":"PrimitiveProperty","label":"Inside Diameter","typeName":"string"},{"name":"OuterDiameter","type":"PrimitiveProperty","label":"Outside Diameter","typeName":"string"},{"name":"MinBendingRadius","type":"PrimitiveProperty","label":"Minimum Bending Radius","typeName":"string"},{"name":"BusbarMaterial","type":"PrimitiveProperty","label":"Bus Bar Material","typeName":"string"},{"name":"Temper","type":"PrimitiveProperty","label":"Temper","typeName":"string"},{"name":"Alloy","type":"PrimitiveProperty","label":"Alloy","typeName":"string"},{"name":"ScheduleNumber","type":"PrimitiveProperty","label":"Schedule Number","typeName":"string"},{"name":"NominalSize","type":"PrimitiveProperty","label":"Nominal Size","typeName":"string"}]},"JunctionSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Junction","description":"A point where one or more conducting equipments are connected with zero resistance.\r ","baseClass":"SubstationSymbolsCustom.ConnectorSymbolsPhysicalTypeAspect","properties":[{"name":"InstallationMethod","type":"PrimitiveProperty","label":"Installation Method","typeName":"string"}]},"EnergyConnectionSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Energy Connection","baseClass":"SubstationSymbolsCustom.EquipmentSymbolsPhysicalTypeAspect"},"EnergySourceSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Energy Source","baseClass":"SubstationSymbolsCustom.EnergyConnectionSymbolsPhysicalTypeAspect"},"EnergyConsumerSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Energy Consumer","baseClass":"SubstationSymbolsCustom.EnergyConnectionSymbolsPhysicalTypeAspect"},"RegulatingConductingEqSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Regulating Conducting Equipment","baseClass":"SubstationSymbolsCustom.EnergyConnectionSymbolsPhysicalTypeAspect"},"GroundSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Grounding Equipment","baseClass":"SubstationSymbolsCustom.EquipmentSymbolsPhysicalTypeAspect","properties":[{"name":"ShortDescription","type":"PrimitiveProperty","label":"Short Description","typeName":"string"}]},"FrequencyConverterSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Frequency Converter","description":"A device to convert from one frequency to another (e.g., frequency F1 to F2) comprises a pair of FrequencyConverter instances. One converts from F1 to DC, the other converts the DC to F2.","baseClass":"SubstationSymbolsCustom.RegulatingConductingEqSymbolsPhysicalTypeAspect","properties":[{"name":"ShortDescription","type":"PrimitiveProperty","label":"Short Description","typeName":"string"},{"name":"NominalVoltage","type":"PrimitiveProperty","label":"Nominal Voltage","typeName":"string"},{"name":"FullLoadKVA","type":"PrimitiveProperty","label":"Full Load KVA","typeName":"string"},{"name":"RatedPower","type":"PrimitiveProperty","label":"Rated Power","typeName":"string"},{"name":"ReactivePower","type":"PrimitiveProperty","label":"Reactive Power","typeName":"string"}]},"StaticVarCompensatorSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Static Var Compensator","description":"A facility for providing variable and controllable shunt reactive power. The SVC typically consists of a stepdown transformer, filter, thyristor-controlled reactor, and thyristor-switched capacitor arms.\r \r The SVC may operate in fixed MVar output mode or in voltage control mode. When in voltage control mode, the output of the SVC will be proportional to the deviation of voltage at the controlled bus from the voltage setpoint. The SVC characteristic slope defines the proportion. If the voltage at the controlled bus is equal to the voltage setpoint, the SVC MVar output is zero.","baseClass":"SubstationSymbolsCustom.RegulatingConductingEqSymbolsPhysicalTypeAspect","properties":[{"name":"ShortDescription","type":"PrimitiveProperty","label":"Short Description","typeName":"string"},{"name":"NominalVoltage","type":"PrimitiveProperty","label":"Nominal Voltage","typeName":"string"},{"name":"WithstandKV","type":"PrimitiveProperty","label":"Withstand KV","typeName":"string"},{"name":"InsulatorType","type":"PrimitiveProperty","label":"Insulator Type","typeName":"string"},{"name":"MaxContCurrent","type":"PrimitiveProperty","label":"Max Continuous Current","typeName":"string"},{"name":"RatedShortTimeCurrent","type":"PrimitiveProperty","label":"Rated short time current","typeName":"string"},{"name":"FluidType","type":"PrimitiveProperty","label":"Fluid Type","typeName":"string"},{"name":"FullLoadKVA","type":"PrimitiveProperty","label":"Full Load KVA","typeName":"string"},{"name":"RatedPower","type":"PrimitiveProperty","label":"Rated Power","typeName":"string"},{"name":"ReactivePower","type":"PrimitiveProperty","label":"Reactive Power","typeName":"string"}]},"ExternalNetworkInjectionSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"External Network Injection","baseClass":"SubstationSymbolsCustom.RegulatingConductingEqSymbolsPhysicalTypeAspect"},"ShuntCompensatorSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Shunt Compensator","baseClass":"SubstationSymbolsCustom.RegulatingConductingEqSymbolsPhysicalTypeAspect","properties":[{"name":"ShortDescription","type":"PrimitiveProperty","label":"Short Description","typeName":"string"},{"name":"NominalVoltage","type":"PrimitiveProperty","label":"Nominal Voltage","typeName":"string"},{"name":"WithstandKV","type":"PrimitiveProperty","label":"Withstand KV","typeName":"string"},{"name":"InsulatorType","type":"PrimitiveProperty","label":"Insulator Type","typeName":"string"},{"name":"RatedShortTimeCurrent","type":"PrimitiveProperty","label":"Rated short time current","typeName":"string"},{"name":"FluidType","type":"PrimitiveProperty","label":"Fluid Type","typeName":"string"},{"name":"TypeOfCooling","type":"PrimitiveProperty","label":"Type Of Cooling","typeName":"string"},{"name":"PrimaryPower","type":"PrimitiveProperty","label":"Primary Power","typeName":"string"},{"name":"NumberOfPhases","type":"PrimitiveProperty","label":"Number of Phases","typeName":"string"},{"name":"ReactivePower","type":"PrimitiveProperty","label":"Reactive Power","typeName":"string"},{"name":"PrimaryBushingBIL","type":"PrimitiveProperty","label":"Primary Bushing BIL","typeName":"string"}]},"PowerElectronicsConnectionSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Power Electronic Connection","baseClass":"SubstationSymbolsCustom.RegulatingConductingEqSymbolsPhysicalTypeAspect","properties":[{"name":"ShortDescription","type":"PrimitiveProperty","label":"Short Description","typeName":"string"},{"name":"NominalVoltage","type":"PrimitiveProperty","label":"Nominal Voltage","typeName":"string"},{"name":"WithstandKV","type":"PrimitiveProperty","label":"Withstand KV","typeName":"string"},{"name":"MaxContCurrent","type":"PrimitiveProperty","label":"Max Continuous Current","typeName":"string"},{"name":"RatedShortTimeCurrent","type":"PrimitiveProperty","label":"Rated short time current","typeName":"string"},{"name":"RatedPower","type":"PrimitiveProperty","label":"Rated Power","typeName":"string"},{"name":"PrimaryCurrent","type":"PrimitiveProperty","label":"Primary Current","typeName":"string"},{"name":"SecondaryCurrent","type":"PrimitiveProperty","label":"Secondary Current","typeName":"string"},{"name":"ReactivePower","type":"PrimitiveProperty","label":"Reactive Power","typeName":"string"},{"name":"InputVoltage","type":"PrimitiveProperty","label":"Input Voltage","typeName":"string"},{"name":"OutputVoltage","type":"PrimitiveProperty","label":"Output Voltage","typeName":"string"}]},"RotatingMachineSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Rotating Machine","baseClass":"SubstationSymbolsCustom.RegulatingConductingEqSymbolsPhysicalTypeAspect","properties":[{"name":"ShortDescription","type":"PrimitiveProperty","label":"Short Description","typeName":"string"},{"name":"NominalVoltage","type":"PrimitiveProperty","label":"Nominal Voltage","typeName":"string"},{"name":"RatedPower","type":"PrimitiveProperty","label":"Rated Power","typeName":"string"},{"name":"PrimaryWindingBIL","type":"PrimitiveProperty","label":"Primary Winding BIL","typeName":"string"},{"name":"ReactivePower","type":"PrimitiveProperty","label":"Reactive Power","typeName":"string"},{"name":"PowerFactor","type":"PrimitiveProperty","label":"Power Factor","typeName":"string"},{"name":"RPM","type":"PrimitiveProperty","label":"RPM","typeName":"string"}]},"DERSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"DER","baseClass":"SubstationSymbolsCustom.EquipmentSymbolsPhysicalTypeAspect"},"AsynchronousMachineSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Asynchronous Machine","baseClass":"SubstationSymbolsCustom.RotatingMachineSymbolsPhysicalTypeAspect"},"SynchronousMachineSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Synchronous Machine","baseClass":"SubstationSymbolsCustom.RotatingMachineSymbolsPhysicalTypeAspect"},"BatterySymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Battery","baseClass":"SubstationSymbolsCustom.DERSymbolsPhysicalTypeAspect"},"SolarPanelSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Solar Panel","baseClass":"SubstationSymbolsCustom.DERSymbolsPhysicalTypeAspect"},"WindTurbineSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Wind Turbine","baseClass":"SubstationSymbolsCustom.DERSymbolsPhysicalTypeAspect"},"LightningProtectionSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Lightning Protection","baseClass":"SubstationSymbolsCustom.EquipmentSymbolsPhysicalTypeAspect","properties":[{"name":"ShortDescription","type":"PrimitiveProperty","label":"Short Description","typeName":"string"},{"name":"PercentSpare","type":"PrimitiveProperty","label":"Percent Spare","typeName":"int"},{"name":"CableCode","type":"PrimitiveProperty","label":"Cable Code","typeName":"string"},{"name":"MinBendingRadius","type":"PrimitiveProperty","label":"Minimum Bending Radius","typeName":"string"},{"name":"AllowableAmpacity","type":"PrimitiveProperty","label":"Allowable Ampacity","typeName":"string"}]},"LightningMastsSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Lightning Masts","baseClass":"SubstationSymbolsCustom.LightningProtectionSymbolsPhysicalTypeAspect"},"ShieldWireSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Shield Wire","baseClass":"SubstationSymbolsCustom.LightningProtectionSymbolsPhysicalTypeAspect"},"OtherAuxiliarySymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Other Auxiliary","baseClass":"SubstationSymbolsCustom.AuxiliaryEquipmentSymbolsPhysicalTypeAspect"},"EMVTSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Electromagnetic Voltage Transformers","description":"Electromagnetic Voltage Transformers \r ","baseClass":"SubstationSymbolsCustom.PotentialTransformerSymbolsPhysicalTypeAspect"},"OVTSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Optical Voltage Transformers","description":"Optical Voltage Transformers \r ","baseClass":"SubstationSymbolsCustom.PotentialTransformerSymbolsPhysicalTypeAspect"},"CCVTSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Capacitive Coupled Voltage Transformer","baseClass":"SubstationSymbolsCustom.PotentialTransformerSymbolsPhysicalTypeAspect"},"CombinedCTVTSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Combined CT/VT ","baseClass":"SubstationSymbolsCustom.SensorSymbolsPhysicalTypeAspect","properties":[{"name":"NominalVoltage","type":"PrimitiveProperty","label":"Nominal Voltage","typeName":"string"},{"name":"WithstandKV","type":"PrimitiveProperty","label":"Withstand KV","typeName":"string"},{"name":"InsulatorType","type":"PrimitiveProperty","label":"Insulator Type","typeName":"string"},{"name":"RatedShortTimeCurrent","type":"PrimitiveProperty","label":"Rated short time current","typeName":"string"},{"name":"InsulationType","type":"PrimitiveProperty","label":"Insulation Type","typeName":"string"},{"name":"FluidType","type":"PrimitiveProperty","label":"Fluid Type","typeName":"string"},{"name":"PrimaryVoltage","type":"PrimitiveProperty","label":"Primary Voltage","typeName":"string"},{"name":"SecondaryVoltage","type":"PrimitiveProperty","label":"Secondary Voltage","typeName":"string"},{"name":"TypeOfCooling","type":"PrimitiveProperty","label":"Type Of Cooling","typeName":"string"},{"name":"Mounting","type":"PrimitiveProperty","label":"Mounting Method","typeName":"string"},{"name":"PrimaryCurrent","type":"PrimitiveProperty","label":"Primary Current","typeName":"string"},{"name":"SecondaryCurrent","type":"PrimitiveProperty","label":"Secondary Current","typeName":"string"},{"name":"CTRatio","type":"PrimitiveProperty","label":"CT Ratio","typeName":"string"},{"name":"VoltageFactor","type":"PrimitiveProperty","label":"Voltage Factor","typeName":"string"},{"name":"ThermalBurden","type":"PrimitiveProperty","label":"Thermal Burden","typeName":"string"},{"name":"PTRatio","type":"PrimitiveProperty","label":"PT Ratio","typeName":"string"},{"name":"WindingRatio","type":"PrimitiveProperty","label":"Winding Ratio","typeName":"string"},{"name":"RatingFactor","type":"PrimitiveProperty","label":"Rating Factor","typeName":"string"},{"name":"BurdenRating","type":"PrimitiveProperty","label":"Burden Rating","typeName":"string"}]},"NeutralGroundingResistorSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Neutral Grounding Resistor","baseClass":"SubstationSymbolsCustom.GroundingImpedanceSymbolsPhysicalTypeAspect"},"NeutralGroundingReactorSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Neutral Grounding Reactor","description":"The conductor used to connect the non-current-carrying metal parts of equipment, raceways and other enclosures to the system grounded conductor, grounding electrode conductor, or both, at the service equipment or at the source of a separately-derived system","baseClass":"SubstationSymbolsCustom.GroundingImpedanceSymbolsPhysicalTypeAspect"},"PowerTransformer2WindingsSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Power Transformer - 2 Windings","baseClass":"SubstationSymbolsCustom.PowerTransformerSymbolsPhysicalTypeAspect","properties":[{"name":"SecondaryVoltage","type":"PrimitiveProperty","label":"Secondary Voltage","typeName":"string"},{"name":"PrimaryWindingConfig","type":"PrimitiveProperty","label":"Primary Winding Configuration","typeName":"string"},{"name":"SecondaryWindingConfig","type":"PrimitiveProperty","label":"Secondary Winding Configuration","typeName":"string"},{"name":"SecondaryWindingBIL","type":"PrimitiveProperty","label":"Secondary Winding BIL","typeName":"string"},{"name":"SecondaryPower","type":"PrimitiveProperty","label":"Secondary Power","typeName":"string"},{"name":"PrimaryTappingRange","type":"PrimitiveProperty","label":"PrimaryTapping Range","typeName":"string"},{"name":"NumberOfPhases","type":"PrimitiveProperty","label":"Number of Phases","typeName":"string"},{"name":"SecondaryTappingRange","type":"PrimitiveProperty","label":"SecondaryTapping Range","typeName":"string"},{"name":"SecondaryBushingBIL","type":"PrimitiveProperty","label":"Secondary Bushing BIL","typeName":"string"},{"name":"SecondaryNeutralBIL","type":"PrimitiveProperty","label":"Secondary Neutral BIL","typeName":"string"},{"name":"SecondaryArresterRating","type":"PrimitiveProperty","label":"Secondary Arrester Rating","typeName":"string"}]},"PowerTransformer3WindingsSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Power Transformer - 3 Windings","baseClass":"SubstationSymbolsCustom.PowerTransformerSymbolsPhysicalTypeAspect","properties":[{"name":"SecondaryVoltage","type":"PrimitiveProperty","label":"Secondary Voltage","typeName":"string"},{"name":"PrimaryWindingConfig","type":"PrimitiveProperty","label":"Primary Winding Configuration","typeName":"string"},{"name":"SecondaryWindingConfig","type":"PrimitiveProperty","label":"Secondary Winding Configuration","typeName":"string"},{"name":"SecondaryWindingBIL","type":"PrimitiveProperty","label":"Secondary Winding BIL","typeName":"string"},{"name":"SecondaryPower","type":"PrimitiveProperty","label":"Secondary Power","typeName":"string"},{"name":"TertiaryWindingConfig","type":"PrimitiveProperty","label":"Tertiary Winding Configuration","typeName":"string"},{"name":"TertiaryWindingBIL","type":"PrimitiveProperty","label":"Tertiary Winding BIL","typeName":"string"},{"name":"TertiaryPower","type":"PrimitiveProperty","label":"Tertiary Power","typeName":"string"},{"name":"PrimaryTappingRange","type":"PrimitiveProperty","label":"PrimaryTapping Range","typeName":"string"},{"name":"NumberOfPhases","type":"PrimitiveProperty","label":"Number of Phases","typeName":"string"},{"name":"ImpedancePrimarySecondary","type":"PrimitiveProperty","label":"Impedance Primary-Secondary","typeName":"string"},{"name":"ImpedancePrimaryTertiary","type":"PrimitiveProperty","label":"Impedance Primary-Tertiary","typeName":"string"},{"name":"ImpedanceSecondaryTertiary","type":"PrimitiveProperty","label":"Impedance Secondary-Tertiary","typeName":"string"},{"name":"TertiaryVoltage","type":"PrimitiveProperty","label":"Tertiary Voltage","typeName":"string"},{"name":"SecondaryTappingRange","type":"PrimitiveProperty","label":"SecondaryTapping Range","typeName":"string"},{"name":"SecondaryBushingBIL","type":"PrimitiveProperty","label":"Secondary Bushing BIL","typeName":"string"},{"name":"TertiaryBushingBIL","type":"PrimitiveProperty","label":"Tertiary Bushing BIL","typeName":"string"},{"name":"SecondaryNeutralBIL","type":"PrimitiveProperty","label":"Secondary Neutral BIL","typeName":"string"},{"name":"SecondaryArresterRating","type":"PrimitiveProperty","label":"Secondary Arrester Rating","typeName":"string"}]},"DistributionTransformerSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Distribution Transformer","baseClass":"SubstationSymbolsCustom.PowerTransformerSymbolsPhysicalTypeAspect","properties":[{"name":"SecondaryVoltage","type":"PrimitiveProperty","label":"Secondary Voltage","typeName":"string"},{"name":"PrimaryWindingConfig","type":"PrimitiveProperty","label":"Primary Winding Configuration","typeName":"string"},{"name":"SecondaryWindingConfig","type":"PrimitiveProperty","label":"Secondary Winding Configuration","typeName":"string"},{"name":"SecondaryWindingBIL","type":"PrimitiveProperty","label":"Secondary Winding BIL","typeName":"string"},{"name":"SecondaryPower","type":"PrimitiveProperty","label":"Secondary Power","typeName":"string"},{"name":"PrimaryTappingRange","type":"PrimitiveProperty","label":"PrimaryTapping Range","typeName":"string"},{"name":"NumberOfPhases","type":"PrimitiveProperty","label":"Number of Phases","typeName":"string"},{"name":"SecondaryTappingRange","type":"PrimitiveProperty","label":"SecondaryTapping Range","typeName":"string"},{"name":"SecondaryBushingBIL","type":"PrimitiveProperty","label":"Secondary Bushing BIL","typeName":"string"},{"name":"SecondaryNeutralBIL","type":"PrimitiveProperty","label":"Secondary Neutral BIL","typeName":"string"},{"name":"SecondaryArresterRating","type":"PrimitiveProperty","label":"Secondary Arrester Rating","typeName":"string"}]},"GroundingTransformerwithResistorSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Zigzag Grounding Transformer with Resistor","baseClass":"SubstationSymbolsCustom.PowerTransformerSymbolsPhysicalTypeAspect","properties":[{"name":"NominalVoltage","type":"PrimitiveProperty","label":"Nominal Voltage","typeName":"string"},{"name":"WithstandKV","type":"PrimitiveProperty","label":"Withstand KV","typeName":"string"},{"name":"InsulatorType","type":"PrimitiveProperty","label":"Insulator Type","typeName":"string"},{"name":"MaxContCurrent","type":"PrimitiveProperty","label":"Max Continuous Current","typeName":"string"},{"name":"RatedShortTimeCurrent","type":"PrimitiveProperty","label":"Rated short time current","typeName":"string"}]},"SeriesCapacitorSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Series Capacitor","baseClass":"SubstationSymbolsCustom.SeriesCompensatorSymbolsPhysicalTypeAspect"},"SeriesReactorSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Series Reactor","baseClass":"SubstationSymbolsCustom.SeriesCompensatorSymbolsPhysicalTypeAspect"},"TCSCSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Thyristor-Controlled Series Capacitor","baseClass":"SubstationSymbolsCustom.SeriesCompensatorSymbolsPhysicalTypeAspect"},"PowerCableSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Power Cable","baseClass":"SubstationSymbolsCustom.ConductorSymbolsPhysicalTypeAspect"},"InsulatedPowerCableSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Insulated Power Cable","baseClass":"SubstationSymbolsCustom.ConductorSymbolsPhysicalTypeAspect","properties":[{"name":"NominalVoltage","type":"PrimitiveProperty","label":"Nominal Voltage","typeName":"string"},{"name":"JacketType","type":"PrimitiveProperty","label":"Jacket Type","typeName":"string"},{"name":"ShieldType","type":"PrimitiveProperty","label":"Shield Type","typeName":"string"},{"name":"InsulationType","type":"PrimitiveProperty","label":"Insulation Type","typeName":"string"},{"name":"CableLayingMethod","type":"PrimitiveProperty","label":"Cable Laying Method","typeName":"string"},{"name":"InsulationThickness","type":"PrimitiveProperty","label":"Cable Insulation Thickness","typeName":"string"},{"name":"GroundSize","type":"PrimitiveProperty","label":"Ground Wire Size","typeName":"string"},{"name":"JacketThickness","type":"PrimitiveProperty","label":"Cable Jacket Thickness","typeName":"string"},{"name":"NeutralSize","type":"PrimitiveProperty","label":"Neutral Wire Size","typeName":"string"}]},"CableClampsSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Cable Clamps","baseClass":"SubstationSymbolsCustom.ClampSymbolsPhysicalTypeAspect"},"BusClampsSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Bus Clamps","baseClass":"SubstationSymbolsCustom.ClampSymbolsPhysicalTypeAspect"},"CableConnectorSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Cable Connector","baseClass":"SubstationSymbolsCustom.JunctionSymbolsPhysicalTypeAspect"},"BusConnectorSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Bus Connector","baseClass":"SubstationSymbolsCustom.JunctionSymbolsPhysicalTypeAspect"},"BusAccessoriesSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Bus Accessories","baseClass":"SubstationSymbolsCustom.ConnectorSymbolsPhysicalTypeAspect","properties":[{"name":"InstallationMethod","type":"PrimitiveProperty","label":"Installation Method","typeName":"string"}]},"CableAccessoriesSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Cable Accessories","baseClass":"SubstationSymbolsCustom.ConnectorSymbolsPhysicalTypeAspect","properties":[{"name":"InstallationMethod","type":"PrimitiveProperty","label":"Installation Method","typeName":"string"}]},"LineHardwareSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Line Hardware","baseClass":"SubstationSymbolsCustom.ConnectorSymbolsPhysicalTypeAspect","properties":[{"name":"InstallationMethod","type":"PrimitiveProperty","label":"Installation Method","typeName":"string"}]},"VoltageRegulatorSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Voltage Regulator","baseClass":"SubstationSymbolsCustom.RegulatingConductingEqSymbolsPhysicalTypeAspect","properties":[{"name":"ShortDescription","type":"PrimitiveProperty","label":"Short Description","typeName":"string"},{"name":"NominalVoltage","type":"PrimitiveProperty","label":"Nominal Voltage","typeName":"string"},{"name":"MechanicalEnduranceClass","type":"PrimitiveProperty","label":"Mechanical Endurance Class","typeName":"string"},{"name":"InsulatorType","type":"PrimitiveProperty","label":"Insulator Type","typeName":"string"},{"name":"AllowableAmpacity","type":"PrimitiveProperty","label":"Allowable Ampacity","typeName":"string"},{"name":"FluidType","type":"PrimitiveProperty","label":"Fluid Type","typeName":"string"},{"name":"PrimaryVoltage","type":"PrimitiveProperty","label":"Primary Voltage","typeName":"string"},{"name":"SecondaryVoltage","type":"PrimitiveProperty","label":"Secondary Voltage","typeName":"string"},{"name":"FullLoadKVA","type":"PrimitiveProperty","label":"Full Load KVA","typeName":"string"},{"name":"Mounting","type":"PrimitiveProperty","label":"Mounting Method","typeName":"string"},{"name":"RatedPower","type":"PrimitiveProperty","label":"Rated Power","typeName":"string"},{"name":"TemperatureRiseOil","type":"PrimitiveProperty","label":"Temperature Rise in Oil","typeName":"string"},{"name":"TemperatureRiseWindings","type":"PrimitiveProperty","label":"Temperature Rise in Windings","typeName":"string"},{"name":"PrimaryTappingRange","type":"PrimitiveProperty","label":"PrimaryTapping Range","typeName":"string"},{"name":"NumberOfPhases","type":"PrimitiveProperty","label":"Number of Phases","typeName":"string"},{"name":"ReactivePower","type":"PrimitiveProperty","label":"Reactive Power","typeName":"string"},{"name":"PrimaryArresterRating","type":"PrimitiveProperty","label":"Primary Arrester Rating","typeName":"string"}]},"ShuntCapacitorSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Shunt Capacitor","description":"Single capacitor unit used to inject reactive power (positive Q) to improve voltage ","baseClass":"SubstationSymbolsCustom.ShuntCompensatorSymbolsPhysicalTypeAspect","properties":[{"name":"FuseRatings","type":"PrimitiveProperty","label":"Fuse Ratings","typeName":"string"}]},"ShuntCapacitorBankSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Shunt Capacitor Bank","description":"Group of capacitor units connected in series/parallel; often switchable in steps \r ","baseClass":"SubstationSymbolsCustom.ShuntCompensatorSymbolsPhysicalTypeAspect","properties":[{"name":"FuseRatings","type":"PrimitiveProperty","label":"Fuse Ratings","typeName":"string"}]},"ShuntReactorSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Shunt Reactor","baseClass":"SubstationSymbolsCustom.ShuntCompensatorSymbolsPhysicalTypeAspect","properties":[{"name":"PrimaryWindingBIL","type":"PrimitiveProperty","label":"Primary Winding BIL","typeName":"string"}]},"ShuntReactorBankSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Shunt Reactor Bank","baseClass":"SubstationSymbolsCustom.ShuntCompensatorSymbolsPhysicalTypeAspect","properties":[{"name":"PrimaryWindingBIL","type":"PrimitiveProperty","label":"Primary Winding BIL","typeName":"string"}]},"RectifierSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Rectifier","baseClass":"SubstationSymbolsCustom.PowerElectronicsConnectionSymbolsPhysicalTypeAspect"},"InverterSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Inverter","baseClass":"SubstationSymbolsCustom.PowerElectronicsConnectionSymbolsPhysicalTypeAspect"},"GroundingRodSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Grounding Rod","baseClass":"SubstationSymbolsCustom.GroundSymbolsPhysicalTypeAspect"},"GroundingGridSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Grounding Grid","baseClass":"SubstationSymbolsCustom.GroundSymbolsPhysicalTypeAspect","properties":[{"name":"RatedShortTimeCurrent","type":"PrimitiveProperty","label":"Rated short time current","typeName":"string"}]},"GroundingClampsSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Grounding Clamps","baseClass":"SubstationSymbolsCustom.GroundSymbolsPhysicalTypeAspect"},"GroundingAccessoriesSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Grounding Accessories","baseClass":"SubstationSymbolsCustom.GroundSymbolsPhysicalTypeAspect","properties":[{"name":"InstallationMethod","type":"PrimitiveProperty","label":"Installation Method","typeName":"string"}]},"BushingSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Bushing","baseClass":"SubstationSymbolsCustom.OtherAuxiliarySymbolsPhysicalTypeAspect","properties":[{"name":"NominalVoltage","type":"PrimitiveProperty","label":"Nominal Voltage","typeName":"string"},{"name":"WithstandKV","type":"PrimitiveProperty","label":"Withstand KV","typeName":"string"},{"name":"InsulatorType","type":"PrimitiveProperty","label":"Insulator Type","typeName":"string"},{"name":"MaxContCurrent","type":"PrimitiveProperty","label":"Max Continuous Current","typeName":"string"},{"name":"InsulationType","type":"PrimitiveProperty","label":"Insulation Type","typeName":"string"},{"name":"FluidType","type":"PrimitiveProperty","label":"Fluid Type","typeName":"string"},{"name":"Mounting","type":"PrimitiveProperty","label":"Mounting Method","typeName":"string"}]},"LineTunerSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Line Tuner","baseClass":"SubstationSymbolsCustom.OtherAuxiliarySymbolsPhysicalTypeAspect"},"SurgeCounterSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Surge Counter","baseClass":"SubstationSymbolsCustom.OtherAuxiliarySymbolsPhysicalTypeAspect"},"GuyStrainInsulatorSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Guy Strain Insulator","baseClass":"SubstationSymbolsCustom.OtherAuxiliarySymbolsPhysicalTypeAspect"},"ArcHornSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Arc Horn","baseClass":"SubstationSymbolsCustom.OtherAuxiliarySymbolsPhysicalTypeAspect"},"CoronaRingSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Corona Ring","baseClass":"SubstationSymbolsCustom.OtherAuxiliarySymbolsPhysicalTypeAspect"},"AnnunciatorSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Annunciator","baseClass":"SubstationSymbolsCustom.OtherAuxiliarySymbolsPhysicalTypeAspect"},"StatusIndicatorSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Status Indicator","baseClass":"SubstationSymbolsCustom.OtherAuxiliarySymbolsPhysicalTypeAspect"},"OverheadStructureSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Overhead Structure","baseClass":"SubstationSymbolsCustom.StructureSymbolsPhysicalTypeAspect","properties":[{"name":"ShortDescription","type":"PrimitiveProperty","label":"Short Description","typeName":"string"}]},"BusStructureSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Bus Structure","baseClass":"SubstationSymbolsCustom.OverheadStructureSymbolsPhysicalTypeAspect"},"EquipmentStructureSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Equipment Structure","baseClass":"SubstationSymbolsCustom.OverheadStructureSymbolsPhysicalTypeAspect"},"DeadEndStructureSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Dead-end Structure","baseClass":"SubstationSymbolsCustom.OverheadStructureSymbolsPhysicalTypeAspect"},"PoleSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Pole","description":"Distribution pole used to support the overhead conductors and related equipment","baseClass":"SubstationSymbolsCustom.OverheadStructureSymbolsPhysicalTypeAspect"},"SupportWireSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Support Wire","baseClass":"SubstationSymbolsCustom.OverheadStructureSymbolsPhysicalTypeAspect"},"CableSupportsSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Cable Supports","baseClass":"SubstationSymbolsCustom.StructureSymbolsPhysicalTypeAspect","properties":[{"name":"ShortDescription","type":"PrimitiveProperty","label":"Short Description","typeName":"string"}]},"GuyWireSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Guy Wire","baseClass":"SubstationSymbolsCustom.SupportWireSymbolsPhysicalTypeAspect"},"GuyWireAccessoriesSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Guy Wire Accessories","baseClass":"SubstationSymbolsCustom.CableSupportsSymbolsPhysicalTypeAspect"},"CableSpacerSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Cable Spacer","baseClass":"SubstationSymbolsCustom.CableSupportsSymbolsPhysicalTypeAspect"},"CableSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Cable","baseClass":"SubstationSymbolsCustom.StructureSymbolsPhysicalTypeAspect"},"SpanGuySymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Span Guy","baseClass":"SubstationSymbolsCustom.CableSymbolsPhysicalTypeAspect"},"DownGuySymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Down Guy","baseClass":"SubstationSymbolsCustom.CableSymbolsPhysicalTypeAspect"},"UndergroundStructureSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Underground Structure","baseClass":"SubstationSymbolsCustom.StructureSymbolsPhysicalTypeAspect","properties":[{"name":"ShortDescription","type":"PrimitiveProperty","label":"Short Description","typeName":"string"}]},"VaultSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Vault","baseClass":"SubstationSymbolsCustom.UndergroundStructureSymbolsPhysicalTypeAspect"},"ManholeSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Manhole","baseClass":"SubstationSymbolsCustom.UndergroundStructureSymbolsPhysicalTypeAspect"},"AnchorCageSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Anchor Cage","baseClass":"SubstationSymbolsCustom.UndergroundStructureSymbolsPhysicalTypeAspect"},"FastenersSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Fasteners","baseClass":"SubstationSymbolsCustom.StructureSymbolsPhysicalTypeAspect","properties":[{"name":"ShortDescription","type":"PrimitiveProperty","label":"Short Description","typeName":"string"}]},"SupportsSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Supports","baseClass":"SubstationSymbolsCustom.StructureSymbolsPhysicalTypeAspect","properties":[{"name":"ShortDescription","type":"PrimitiveProperty","label":"Short Description","typeName":"string"}]},"BoltSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Bolt","baseClass":"SubstationSymbolsCustom.FastenersSymbolsPhysicalTypeAspect"},"WasherSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Washer","baseClass":"SubstationSymbolsCustom.FastenersSymbolsPhysicalTypeAspect"},"NutsSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Nuts","baseClass":"SubstationSymbolsCustom.FastenersSymbolsPhysicalTypeAspect"},"ScrewSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Screw","baseClass":"SubstationSymbolsCustom.FastenersSymbolsPhysicalTypeAspect"},"LiftingLugsSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Lifting Lugs","baseClass":"SubstationSymbolsCustom.FastenersSymbolsPhysicalTypeAspect"},"BusSupportSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Bus Support","baseClass":"SubstationSymbolsCustom.SupportsSymbolsPhysicalTypeAspect","properties":[{"name":"Mounting","type":"PrimitiveProperty","label":"Mounting Method","typeName":"string"}]},"BracketSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Bracket","baseClass":"SubstationSymbolsCustom.SupportsSymbolsPhysicalTypeAspect"},"UboltSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"U-Bolt","baseClass":"SubstationSymbolsCustom.SupportsSymbolsPhysicalTypeAspect"},"MountingKitSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Mounting Kit","description":"Additional components needed to mount equipment","baseClass":"SubstationSymbolsCustom.SupportsSymbolsPhysicalTypeAspect"},"PlatformSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Platform","baseClass":"SubstationSymbolsCustom.FoundationSymbolsPhysicalTypeAspect"},"EquipmentFoundationSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Equipment Foundation","baseClass":"SubstationSymbolsCustom.FoundationSymbolsPhysicalTypeAspect"},"StructureFoundationSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Structure Foundation","baseClass":"SubstationSymbolsCustom.FoundationSymbolsPhysicalTypeAspect"},"WalkingPlatformSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Walking platform","baseClass":"SubstationSymbolsCustom.PlatformSymbolsPhysicalTypeAspect"},"SwitchOperatorPlatformSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Switch Operator Platform","baseClass":"SubstationSymbolsCustom.PlatformSymbolsPhysicalTypeAspect"},"ElectricalBuildingSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Electrical Building","baseClass":"SubstationSymbolsCustom.SubstationSymbolsPhysicalTypeAspect"},"LVSwitchSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"LV Switches","baseClass":"SubstationSymbolsCustom.ElectricalBuildingSymbolsPhysicalTypeAspect","properties":[{"name":"NominalVoltage","type":"PrimitiveProperty","label":"Nominal Voltage","typeName":"string"}]},"AudioVisualDeviceSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Audio Visual Device","baseClass":"SubstationSymbolsCustom.ElectricalBuildingSymbolsPhysicalTypeAspect"},"CommunicationDeviceSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Communication Device","baseClass":"SubstationSymbolsCustom.ElectricalBuildingSymbolsPhysicalTypeAspect"},"ElectricPanelSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Electric Panel","baseClass":"SubstationSymbolsCustom.ElectricalBuildingSymbolsPhysicalTypeAspect"},"LVBatterySymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Low Voltage Battery","description":"A device in which electrical energy is stored and from which energy may be progressively released.","baseClass":"SubstationSymbolsCustom.ElectricalBuildingSymbolsPhysicalTypeAspect","properties":[{"name":"RatedPower","type":"PrimitiveProperty","label":"Rated Power","typeName":"string"},{"name":"InputVoltage","type":"PrimitiveProperty","label":"Input Voltage","typeName":"string"},{"name":"OutputVoltage","type":"PrimitiveProperty","label":"Output Voltage","typeName":"string"}]},"ConditionerDeviceSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Conditioner Device","description":"used to remove unwanted matter from an electric or electronic signal","baseClass":"SubstationSymbolsCustom.ElectricalBuildingSymbolsPhysicalTypeAspect"},"ElectricLoadTimeControlSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Electric Load Time Control","description":"A device that applies control to the provision or flow of electrical energy over time ","baseClass":"SubstationSymbolsCustom.ElectricalBuildingSymbolsPhysicalTypeAspect"},"PowerOutletSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Outlet","baseClass":"SubstationSymbolsCustom.ElectricalBuildingSymbolsPhysicalTypeAspect"},"FanSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Fan","baseClass":"SubstationSymbolsCustom.ElectricalBuildingSymbolsPhysicalTypeAspect","properties":[{"name":"NominalVoltage","type":"PrimitiveProperty","label":"Nominal Voltage","typeName":"string"},{"name":"RatedPower","type":"PrimitiveProperty","label":"Rated Power","typeName":"string"},{"name":"NumberOfPhases","type":"PrimitiveProperty","label":"Number of Phases","typeName":"string"},{"name":"PowerFactor","type":"PrimitiveProperty","label":"Power Factor","typeName":"string"},{"name":"RPM","type":"PrimitiveProperty","label":"RPM","typeName":"string"}]},"LightingFixtureSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Lighting Fixture","baseClass":"SubstationSymbolsCustom.ElectricalBuildingSymbolsPhysicalTypeAspect","properties":[{"name":"RatedPower","type":"PrimitiveProperty","label":"Rated Power","typeName":"string"},{"name":"PowerFactor","type":"PrimitiveProperty","label":"Power Factor","typeName":"string"},{"name":"LightOutput","type":"PrimitiveProperty","label":"Light Output","typeName":"string"},{"name":"LightColor","type":"PrimitiveProperty","label":"light Color","typeName":"string"}]},"PowerBatterySymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Power Battery","baseClass":"SubstationSymbolsCustom.ElectricalBuildingSymbolsPhysicalTypeAspect","properties":[{"name":"NominalVoltage","type":"PrimitiveProperty","label":"Nominal Voltage","typeName":"string"},{"name":"WithstandKV","type":"PrimitiveProperty","label":"Withstand KV","typeName":"string"},{"name":"MaxContCurrent","type":"PrimitiveProperty","label":"Max Continuous Current","typeName":"string"},{"name":"RatedShortTimeCurrent","type":"PrimitiveProperty","label":"Rated short time current","typeName":"string"},{"name":"RatedPower","type":"PrimitiveProperty","label":"Rated Power","typeName":"string"}]},"EnclosureSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Enclosure","baseClass":"SubstationSymbolsCustom.ElectricalBuildingSymbolsPhysicalTypeAspect"},"SolarDeviceSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Solar Device","baseClass":"SubstationSymbolsCustom.ElectricalBuildingSymbolsPhysicalTypeAspect"},"RacewaySymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Raceway","baseClass":"SubstationSymbolsCustom.SubstationSymbolsPhysicalTypeAspect"},"CoverSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Cover","baseClass":"SubstationSymbolsCustom.EnclosureSymbolsPhysicalTypeAspect"},"CabinetSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Cabinet","baseClass":"SubstationSymbolsCustom.EnclosureSymbolsPhysicalTypeAspect"},"GasketSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Gasket","baseClass":"SubstationSymbolsCustom.EnclosureSymbolsPhysicalTypeAspect"},"SecondaryCutOutSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Secondary Cut Out","baseClass":"SubstationSymbolsCustom.EnclosureSymbolsPhysicalTypeAspect"},"PanelboardAssemblySymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Panel Board Assembly","baseClass":"SubstationSymbolsCustom.EnclosureSymbolsPhysicalTypeAspect"},"PullBoxSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Pull Box","baseClass":"SubstationSymbolsCustom.EnclosureSymbolsPhysicalTypeAspect"},"JunctionBoxSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Junction Box","description":"A point where one or more conducting equipments are connected with zero resistance.","baseClass":"SubstationSymbolsCustom.EnclosureSymbolsPhysicalTypeAspect","properties":[{"name":"PercentSpare","type":"PrimitiveProperty","label":"Percent Spare","typeName":"int"},{"name":"BusbarMaterial","type":"PrimitiveProperty","label":"Bus Bar Material","typeName":"string"},{"name":"RatedPower","type":"PrimitiveProperty","label":"Rated Power","typeName":"string"}]},"OutletBodySymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Outlet Body","baseClass":"SubstationSymbolsCustom.EnclosureSymbolsPhysicalTypeAspect"},"CableTrenchSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Cable Trench","baseClass":"SubstationSymbolsCustom.RacewaySymbolsPhysicalTypeAspect"},"DuctbankSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Duct bank","baseClass":"SubstationSymbolsCustom.RacewaySymbolsPhysicalTypeAspect"},"CableTraySymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Cable Tray","baseClass":"SubstationSymbolsCustom.RacewaySymbolsPhysicalTypeAspect","properties":[{"name":"NumberOfDividers","type":"PrimitiveProperty","label":"Number Of Dividers","typeName":"string"},{"name":"TradeWidth","type":"PrimitiveProperty","label":"Trade Width","typeName":"string"},{"name":"TradeHeight","type":"PrimitiveProperty","label":"Trade Height","typeName":"string"},{"name":"LoadingDepth","type":"PrimitiveProperty","label":"Loading Depth","typeName":"string"},{"name":"MaxFillFactor","type":"PrimitiveProperty","label":"Max Fill Factor","typeName":"string"},{"name":"SpareCapacity","type":"PrimitiveProperty","label":"Spare Capacity","typeName":"string"},{"name":"CableLayingMethod","type":"PrimitiveProperty","label":"Cable Laying Method","typeName":"string"},{"name":"CablesVoltageLevels","type":"PrimitiveProperty","label":"Cables Voltage Levels","typeName":"string"}]},"CableLadderSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Cable Ladder","baseClass":"SubstationSymbolsCustom.RacewaySymbolsPhysicalTypeAspect","properties":[{"name":"RungsSpacing","type":"PrimitiveProperty","label":"Rungs Spacing","typeName":"string"},{"name":"NumberOfDividers","type":"PrimitiveProperty","label":"Number Of Dividers","typeName":"string"},{"name":"TradeWidth","type":"PrimitiveProperty","label":"Trade Width","typeName":"string"},{"name":"TradeHeight","type":"PrimitiveProperty","label":"Trade Height","typeName":"string"},{"name":"LoadingDepth","type":"PrimitiveProperty","label":"Loading Depth","typeName":"string"},{"name":"MaxFillFactor","type":"PrimitiveProperty","label":"Max Fill Factor","typeName":"string"},{"name":"SpareCapacity","type":"PrimitiveProperty","label":"Spare Capacity","typeName":"string"},{"name":"CableLayingMethod","type":"PrimitiveProperty","label":"Cable Laying Method","typeName":"string"},{"name":"CablesVoltageLevels","type":"PrimitiveProperty","label":"Cables Voltage Levels","typeName":"string"}]},"CableLadderFittingSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Cable Ladder Fitting","baseClass":"SubstationSymbolsCustom.RacewaySymbolsPhysicalTypeAspect","properties":[{"name":"TradeWidth","type":"PrimitiveProperty","label":"Trade Width","typeName":"string"},{"name":"TradeHeight","type":"PrimitiveProperty","label":"Trade Height","typeName":"string"},{"name":"LoadingDepth","type":"PrimitiveProperty","label":"Loading Depth","typeName":"string"},{"name":"MaxFillFactor","type":"PrimitiveProperty","label":"Max Fill Factor","typeName":"string"},{"name":"SpareCapacity","type":"PrimitiveProperty","label":"Spare Capacity","typeName":"string"},{"name":"CableLayingMethod","type":"PrimitiveProperty","label":"Cable Laying Method","typeName":"string"},{"name":"CablesVoltageLevels","type":"PrimitiveProperty","label":"Cables Voltage Levels","typeName":"string"},{"name":"MinBendingRadius","type":"PrimitiveProperty","label":"Minimum Bending Radius","typeName":"string"},{"name":"Angle","type":"PrimitiveProperty","label":"Angle","typeName":"string"}]},"CableTrayFittingsSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Cable Tray Fittings","baseClass":"SubstationSymbolsCustom.RacewaySymbolsPhysicalTypeAspect","properties":[{"name":"TradeWidth","type":"PrimitiveProperty","label":"Trade Width","typeName":"string"},{"name":"TradeHeight","type":"PrimitiveProperty","label":"Trade Height","typeName":"string"},{"name":"LoadingDepth","type":"PrimitiveProperty","label":"Loading Depth","typeName":"string"},{"name":"MaxFillFactor","type":"PrimitiveProperty","label":"Max Fill Factor","typeName":"string"},{"name":"SpareCapacity","type":"PrimitiveProperty","label":"Spare Capacity","typeName":"string"},{"name":"CableLayingMethod","type":"PrimitiveProperty","label":"Cable Laying Method","typeName":"string"},{"name":"CablesVoltageLevels","type":"PrimitiveProperty","label":"Cables Voltage Levels","typeName":"string"},{"name":"MinBendingRadius","type":"PrimitiveProperty","label":"Minimum Bending Radius","typeName":"string"},{"name":"Angle","type":"PrimitiveProperty","label":"Angle","typeName":"string"}]},"CableTrayCoverSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Cable Tray Cover","baseClass":"SubstationSymbolsCustom.RacewaySymbolsPhysicalTypeAspect","properties":[{"name":"TradeWidth","type":"PrimitiveProperty","label":"Trade Width","typeName":"string"},{"name":"TradeHeight","type":"PrimitiveProperty","label":"Trade Height","typeName":"string"},{"name":"MaxFillFactor","type":"PrimitiveProperty","label":"Max Fill Factor","typeName":"string"},{"name":"SpareCapacity","type":"PrimitiveProperty","label":"Spare Capacity","typeName":"string"},{"name":"CableLayingMethod","type":"PrimitiveProperty","label":"Cable Laying Method","typeName":"string"},{"name":"CablesVoltageLevels","type":"PrimitiveProperty","label":"Cables Voltage Levels","typeName":"string"}]},"WirewaySymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Wireway","baseClass":"SubstationSymbolsCustom.RacewaySymbolsPhysicalTypeAspect","properties":[{"name":"NumberOfDividers","type":"PrimitiveProperty","label":"Number Of Dividers","typeName":"string"},{"name":"TradeWidth","type":"PrimitiveProperty","label":"Trade Width","typeName":"string"},{"name":"TradeHeight","type":"PrimitiveProperty","label":"Trade Height","typeName":"string"},{"name":"LoadingDepth","type":"PrimitiveProperty","label":"Loading Depth","typeName":"string"},{"name":"MaxFillFactor","type":"PrimitiveProperty","label":"Max Fill Factor","typeName":"string"},{"name":"SpareCapacity","type":"PrimitiveProperty","label":"Spare Capacity","typeName":"string"},{"name":"CableLayingMethod","type":"PrimitiveProperty","label":"Cable Laying Method","typeName":"string"},{"name":"CablesVoltageLevels","type":"PrimitiveProperty","label":"Cables Voltage Levels","typeName":"string"}]},"ConduitFittingSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Conduit Fittings","baseClass":"SubstationSymbolsCustom.RacewaySymbolsPhysicalTypeAspect","properties":[{"name":"TradeDiameter","type":"PrimitiveProperty","label":"Trade Diameter","typeName":"string"},{"name":"MaxFillFactor","type":"PrimitiveProperty","label":"Max Fill Factor","typeName":"string"},{"name":"SpareCapacity","type":"PrimitiveProperty","label":"Spare Capacity","typeName":"string"},{"name":"CablesVoltageLevels","type":"PrimitiveProperty","label":"Cables Voltage Levels","typeName":"string"},{"name":"InnerDiameter","type":"PrimitiveProperty","label":"Inside Diameter","typeName":"string"},{"name":"OuterDiameter","type":"PrimitiveProperty","label":"Outside Diameter","typeName":"string"},{"name":"MinBendingRadius","type":"PrimitiveProperty","label":"Minimum Bending Radius","typeName":"string"},{"name":"Angle","type":"PrimitiveProperty","label":"Angle","typeName":"string"}]},"ConduitSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Conduit","baseClass":"SubstationSymbolsCustom.RacewaySymbolsPhysicalTypeAspect","properties":[{"name":"TradeDiameter","type":"PrimitiveProperty","label":"Trade Diameter","typeName":"string"},{"name":"NumberOfDividers","type":"PrimitiveProperty","label":"Number Of Dividers","typeName":"string"},{"name":"MaxFillFactor","type":"PrimitiveProperty","label":"Max Fill Factor","typeName":"string"},{"name":"SpareCapacity","type":"PrimitiveProperty","label":"Spare Capacity","typeName":"string"},{"name":"CablesVoltageLevels","type":"PrimitiveProperty","label":"Cables Voltage Levels","typeName":"string"},{"name":"InnerDiameter","type":"PrimitiveProperty","label":"Inside Diameter","typeName":"string"},{"name":"OuterDiameter","type":"PrimitiveProperty","label":"Outside Diameter","typeName":"string"}]},"MiscellaneousSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Miscellaneous","baseClass":"SubstationSymbolsCustom.SubstationSymbolsPhysicalTypeAspect"},"FenceSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Fence","baseClass":"SubstationSymbolsCustom.MiscellaneousSymbolsPhysicalTypeAspect"},"GateSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Gate","baseClass":"SubstationSymbolsCustom.MiscellaneousSymbolsPhysicalTypeAspect"},"ControlBuildingSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Control Building","baseClass":"SubstationSymbolsCustom.MiscellaneousSymbolsPhysicalTypeAspect"},"OilContainmentSystemSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Oil Containment System","baseClass":"SubstationSymbolsCustom.MiscellaneousSymbolsPhysicalTypeAspect"},"PhysicalSafetyBarrierSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Physical Safety Barrier","baseClass":"SubstationSymbolsCustom.MiscellaneousSymbolsPhysicalTypeAspect"},"GeneralHardwareSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"General Hardware","baseClass":"SubstationSymbolsCustom.MiscellaneousSymbolsPhysicalTypeAspect"},"NameplateSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Nameplate","description":"Mounted on the equipment, and contains most relevant equipment attributes. Can be provided by manufacturer or created by utility using the data from design.","baseClass":"SubstationSymbolsCustom.MiscellaneousSymbolsPhysicalTypeAspect"},"TerrainSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Terrain","description":"DTM Terrain","baseClass":"SubstationSymbolsCustom.MiscellaneousSymbolsPhysicalTypeAspect","properties":[{"name":"TerrainMaterial","type":"PrimitiveProperty","label":"Terrain Material","typeName":"string"}]},"AnimalGuardSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Animal Guard","baseClass":"SubstationSymbolsCustom.PhysicalSafetyBarrierSymbolsPhysicalTypeAspect"},"FireBarrierSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Fire Barrier","baseClass":"SubstationSymbolsCustom.PhysicalSafetyBarrierSymbolsPhysicalTypeAspect"},"VehicleBarrierSymbolsPhysicalTypeAspect":{"schemaItemType":"EntityClass","label":"Vehicle Barrier","baseClass":"SubstationSymbolsCustom.PhysicalSafetyBarrierSymbolsPhysicalTypeAspect"}}}